DSC | NT9005 | NT9005 Envoy Spec Sheet

LCD Spec Sheet
10/4/01
7:48
Page 2
SELF-CONTAINED WIRELESS SECURITY SYSTEM
The Envoy LCD system is the ultimate
in advanced wireless security
protection. It installs in minutes and
provides years of reliable security for
your valued customers.
™
ENVOY LCD SYSTEM FEATURES...
• Large fixed message LCD screen
Provides system status, troubles and real-time clock
• ‘Flash Programming’
Provides instructions to assist the installer to program the system
in minutes
• Up to 32 wireless zones
Provides full security protection
In addition to a full range of standard
features, the Envoy LCD system also
includes LCD-driven ‘Flash
Programming’, a large LCD message
screen, 32 wireless zones, and backup
communications capability.
• Up to 2 hardwired zones
Use to provide additional features such as keyswitch arming
• 32 user codes
Enough for any application
• 16 wireless keys
Easily added to the system without sacrificing zone inputs
• Self-powered PC-Link™
Offers programming flexibility on-site or remotely
• Local sounder
Envoy control unit has a built-in 85 dB sounder for immediate
alarm notification
• Alternate communication (Skyroute™, LINKS2150™, LINKS2450™)
The quality, flexibility, and reliability of
the Envoy LCD wireless security
system make it the perfect choice for
your customers’ security needs.
Provides wireless communication to the central station even when there
is no telephone service
• Personal paging
System can be programmed to call a pager when an alarm occurs,
when the system arms or disarms, and on most other system events
• Local & remote PC programming
Program the system from a PC, using DSC’s DLS-3 downloading
software either locally via a direct connection, or remotely from a dialup connection
Self-Contained Wireless Security System That ‘Installs in a Flash’
LCD Spec Sheet
10/4/01
7:48
Page 3
SYSTEM FEATURES, CONTINUED
• Door chime...
- monitor a zone by having the keypad beep when the zone is
open and again when it is closed
• 128-event alarm history buffer...
- all events are automatically stored in a memory buffer with
time and date stamp
- events can be uploaded, viewed, and printed on a PC using
DLS-3 software
• Local PC-Link & remote upload/download capability...
- program the system using DLS-3 software and direct PC connection
to the control panel or from a remote PC over the telephone line
- view status and trouble conditions, and system’s 128-event buffer
- remote access can be controlled by owner to prevent unauthorized
access to the system
LCD-DRIVEN ‘FLASH PROGRAMMING’
• Provides instructions to guide installer through
the programming of...
-
device enrollment on a specific zone
central station telephone number
system account code
placement tests for each wireless detector
• Automatically determines the type of detector (e.g.,
contact -vs- PIR) and sets default zone definitions to
suit standard installations
- these may be programmed to accommodate custom
installation requirements
• ‘Flash Programming’ placement test ensures reliable
communications between the main control unit and
the detectors
• EEPROM memory...
- system will not lose programming or system status on complete AC
and battery failure (will lose recorded zone labels)
• Power requirements...
- 9 VAC, 20 VA plug-in transformer (supplied)
- 6 volt, 3.5 Ah rechargeable sealed lead acid battery (supplied)
FLEXIBLE COMMUNICATIONS
POWER-DRIVEN
• Offers the functionality and feature set of the proven
PowerSeries™ security systems
SYSTEM PACK
• Digital telephone communicator fully programmable for...
- individual reporting of all alarms, supervisories, and restorals
- open/close, partial close reporting by access code
- supports all major formats including SIA, Contact ID, and
20 bps formats
- automatic SIA & Contact ID reporting codes
- 3 telephone numbers
- 2 account codes
- DTMF and pulse dialing
- DPDT line seizure
- split reporting of selected transmissions to each telephone number
- event-initiated personal paging
- alternate wireless communications using Skyroute or
LINKS transmitters
FULLY SUPERVISED
• System is continuously monitored for the following
trouble conditions:
-
System low battery
Fire trouble
AC power failure
Telephone line trouble
Device low battery
Loss of internal clock
Zone faults and tampers
Failure to communicate
RF jamming
FALSE ALARM PREVENTION
•
•
•
•
•
•
•
•
•
Audible exit delay
Audible exit fault
‘Quick Exit’
‘Urgency’ on entry delay
Swinger shutdown
Recent closing transmission
Communication delay
Rotating keypress buffer
Arm/disarm bell squawk
ENVOYLCD1... System Pack
•
•
•
•
•
NT9005-433... main control unit
One 9V, 20VA plug-in transformer
One 6V, 3.5Ah rechargeable sealed lead acid battery
2 WLS925L-433... mini door/window contacts
1 WLS904PL-433... PIR motion detector with pet immunity
DESK-MOUNT KIT
NT9005DMK
• Converts any Envoy LCD wallmount system into a convenient
desktop model
• Reduces installation time
• Comes with two 6ft (1.8m)
phone cables
LCD Spec Sheet
10/4/01
7:48
Page 4
MORE SYSTEM FEATURES
• 32 fully programmable zones...
- two zones can be hardwired
- 25 zone types, 8 programmable zone attributes
• 5 programmable one-touch function keys with 16 options,
such as ‘STAY’ arm, ‘AWAY’ arm, ‘Chime’ and ‘Quick Exit’
• 3 keypad-activated alarms... Fire, Auxiliary, and Panic
• System supports...
-
32 wireless devices
16 wireless keys
2 keyswitches for arming & disarming the system on hardwired zones
integral keypad on main control unit
• 38 programmable 4 or 6-digit access codes...
- 32 user codes, 1 master code, 2 supervisor codes, 2 duress codes, and 1
maintenance code
• Keypad lockout...
- panel can be programmed to lock out keypad if a series of incorrect
access code entries is made
• ‘Quick Arm’ & ‘Quick Exit’...
- to avoid false alarms, 2 keys for each alarm must be pressed
simultaneously and held for 2 seconds before an alarm is generated
• 3 LED indicators... Ready, Armed, and System
- allow system status to be viewed at a glance
• Keypad-activated alarm output and communicator test
• Automatic arming...
- program system to automatically arm at the same or variable
times each day
- programmable pre-alert and bell squawk during auto-arm to notify
anyone on premises and prevent false alarms
• Built-in sounder...
- allow users to arm and exit easily
- capable of ‘Fire Bell Continuous’ or ‘Temporal Three’ fire signal
- silent or audible sounder operation, programmable by zone
• ‘STAY’/’AWAY’ zones and ‘STAY’ arming...
- security of perimeter arming while the premises are occupied
• PGM outputs...
- up to 2 open collector on-board PGM outputs (if no zones are used)
- up to 4 PGM outputs using the NT9204 ouput module
Installs in a ‘Flash’
FIXED MESSAGE LCD
Dual-key emergency buttons for
panic, fire, & auxiliary
Provides user with immediate
notification of system events,
troubles and real-time clock at
a glance.
KEYPAD
LED INDICATORS
EMERGENCY KEYS
Ready, Armed, and Trouble
Numeric keypad with large
backlit buttons
ONE-TOUCH FUNCTION
KEYS
16 programmable options
PROGRAMMING
SELF-POWERED PC-LINK
The Envoy LCD system installation process is fast and simple, with no need to
read a lengthy manual to program main system functions. The system is
shipped ready to install with a peel-off label, providing a quick reference guide
for 'Flash Programming’.
The self-powered PC-Link allows for direct-connect computer programming of
the NT9005 without the need for a modem. It also permits computer
programming of the NT9005 without having to connect AC power directly to the
unit. With PC-Link5SP, simply connect the PC-Link5SP PCB to the 5-pin header
on the back of the NT9005. This connection will power the unit and the DLS
session will automatically begin if you have selected an upload or a download.
This makes programming before the installation a snap.
Advanced programming provides greater flexibility in security system
customization. System modifications can include changes to entry and exit
delay times, zone definitions, and the enabling and disabling of specific system
options.
You can program the Envoy LCD system using DSC's Windows® downloading
software (DLS-3). DLS-3 software enables direct system programming via a
locally connected personal computer or remote programming, using a dial-up
connection. DLS-3 software can also be used to view system status, trouble
conditions, and the system’s 128-event buffer.
SKYROUTE / LINKS2150 / LINKS2450 SUPPORT
The Skyroute wireless communication module ensures panel communication
even when the phone lines are down or cut. The NT9204 High Current
Output/Power Supply module is required in order to connect the Skyroute and
LINKS modules to the NT9005.
LCD Spec Sheet
10/4/01
7:48
Page 1
WIRELESS PET-IMMUNE PIRS
WLS914-433*** Dual-Element PetImmune PIR
•
•
•
•
•
PIR with Multi-Level Signal Processing (MLSP)
Coverage up to: 40'L x 50'W (12.2 x 15.2m)
Two dual-element low noise sensors
For one pet weighing up to 85 lbs (38kg)
Excellent false alarm immunity and catch
performance
• Temperature compensation
• 4 AA batteries (supplied)
WLS904PL-433*** PIR with Pet Immunity
•
•
•
•
•
•
Vertical beam shaping lens*
Coverage up to 40’L x 40’W (12.2 x 12.2m)
Immunity for multiple pets - 60lbs (27.3kg) total
Excellent false alarm immunity and catch performance
High traffic shutdown to preserve battery life
2 lithium batteries (supplied)
PHOTOELECTRIC SMOKE DETECTOR**
WIRELESS TRANSMITTERS & CONTACTS
WLS906-433*** PHOTOELECTRIC SMOKE
DETECTOR
WLS907T-433 LOW TEMPERATURE
SENSOR***
• UL/ULC Listed**
• Exclusive (patented) smoke chamber design
provides:
• Sends an alarm when a pre-defined low
temperature is reached
• The pre-defined temperature points at which
alarm and restoral signals are sent are:
- maximum smoke detection
- exceptional resistance to dust,
insects and air turbulence, thereby
reducing false alarms
- Alarm:
- Restoral:
• Fully supervised
• 3 AAA batteries (supplied)
•
•
•
•
90° smoke detection pattern
Red solid-state LED indicator
Loud 85dB alarm horn
Automatic self-test once every 40 seconds with
visible and audible trouble indication for low
smoke sensitivity and low battery
• Manual user sensitivity test button with local
indication of test result
• Installer test mode allows test locally or by
transmission to central station
• 6 AA batteries (supplied)
GLASSBREAK DETECTION
WLS925L-433 MINI DOOR/WINDOW
CONTACT***
•
•
•
•
•
WLS909-433 & WLS919-433
WIRELESS KEYS
WLS919
NA # 29004328 R001
• WLS919-433 features a slide cover,
preventing accidental activation
• 4 programmable function buttons...
- Preprogrammed for ‘STAY' arm, 'AWAY'
arm, Disarm, and Panic
• Supervised for low battery
• Water-resistant (WLS919 only)
• 2 long-life lithium batteries
POWER SUPPLY/ OUTPUT EXPANSION
NT9204 High Current Output Module
• Provides 4 high current PGM outputs (output 1
is supervised)
• Provides up to 1.0A of additional current
• Battery backup
A magnetic door or window contact
Complete with surface-mount magnet
Terminal connection for an external contact
1 lithium battery (supplied)
Available with a wall tamper switch
(WLS935L-433)
WIRELESS KEYS
WLS912L-433*** GLASSBREAK DETECTOR
• Exceptional microphone frequency range
provides excellent sound capture at low
sound levels and distances up to 25ft (7.6m)
• Detects breakage of all common types of
framed glass including plate, float, wired,
tempered, and laminated
• 2 lithium batteries (supplied)
43˚F ± 3˚F (6˚C ± 2˚C)
48˚F ± 3˚F (9˚C ± 2˚C)
(supplied with WLS919)
WLS909
• 3 x A76 batteries
(supplied with WLS909)
*
Patent pending
** For residential applications only
*** Supervised for tamper, device fault, low battery
©2001 Digital Security Controls Ltd.
Toronto, Canada
Printed in Canada 10/01
DSC® and Envoy™ are trademarks of Digital Security Controls Ltd. and may not be reproduced
without permission.
www.dsc.com
An ISO9001 registered company
Download PDF