Catálogo general Thermax Llama directa GD

Catálogo general Thermax Llama directa GD
Cooling & Heating Division
EcoChill N
The eco - friendly solution ...
for airconditioning and industrial cooling
10 NTR - 210 NTR
35 kW - 739 kW
Fuel Driven Absorption
Chillers-Heaters
Improving your business
is our business
T
hermax offers services,
products and solutions in the field
of energy and environment to
industrial and commercial
segments around the world. Our
business expertise covers
heating, cooling, waste heat
recovery, captive power, water
treatment & recycling, air
pollution control, waste
management and performance
chemicals.
THERMAX - Conserving Energy
Preserving The Environment
THERMAX brings to customers
enriched experience of industrial
applications, and expertise
through technological partnership
and strategic alliance.
Operating from its Headquarters
in Pune (Western India),
THERMAX has built an
international sales & service
network spread over South East
Asia, Middle East, Africa, Russia,
UK and the US. It has a fullfledged ISO 9001 : 2000 and ISO
14000 accredited manufacturing
setups.
Cooling & Heating Division Cooling SBU
Cooling unit of C&H Division offers
expert solutions in Process Chilling
& air conditioning for industrial as
well as commercial applications.
We also provide customized
solution as per the requirement.
Vapor Absorption technology from
THERMAX is at work for clients in
Pharma, Chemical, Fertilizer,
Textile, Petrochemicals &
Automobile industries as well as in
Hotels, Cinema halls, Shopping
Complexes & Office Buildings,
round the globe.
THERMAX, a technology driven company has been in the core
sectors of Energy & Environment for more than 4 decades and has
defined it's business objective as “Conserving energy and
preserving the environment”. THERMAX has established itself as
Numero-Uno in its field by providing comprehensive solutions to
industry.
THERMAX's manufacturing capabilities are confirmed by the fact
that, over the years, THERMAX has installed numerous chillers in all
major countries like USA, Germany, Spain, UK, Italy, Middle East,
South East Asia with the product conforming to the respective
country standards like ETL, CE, TUV, DNV, ASME, etc. Today,
THERMAX is doing business of vapour absorption chillers in all
major countries of world. THERMAX Inc. in USA, THERMAX Europe
Ltd. in UK, THERMAX do Brasil in Sao Paulo & THERMAX Hong
Kong Ltd. are fully owned subsidiaries of THERMAX.
THERMAX believes in efficient and responsive services to our client
and we exhibit it in our way of business, by giving most optimal and
quality solutions, and to achieve customer delight. THERMAX has a
worldwide network of its Sales, Service & Distribution Network
offices to fulfill the needs of its valuable customers.
Technology Leadership
Our Core Competency
We, in THERMAX nurture innovation and encourage development at all levels of working, which has
contributed significantly in raising the performance and efficiency parameters of our technology &
products. Dedicated Research and Development Group has achieved spectacular breakthroughs in
absorption cooling technology over the years. Our Cogenie series of Hot Water Absorption Chillers
received the prestigious “Energy Product of the year” Award in the UK. Our Trigenie series of Multi energy
driven absorption chillers bagged the first prize in the most innovative product design category in "Bry Air
Awards for Excellence in HVAC & R 2006".
THERMAX engineered products have created many delighted customers in India and all over the world
including markets like Europe and USA . Some of the most prestigious names in the world have chosen
THERMAX Absorption Chillers to meet their cooling requirements which includes Mercedes - Germany,
Bosch - Germany, Astra Zeneca - UK , Henry Ford Museum - USA , State University of New York, BBC UK and the like.
Features & Benefits
The EcoChill N series represents a major advance in Absorption Chiller-Heater performance. The earlier
generation of Absorption Chiller-Heater offered significant advantages over conventional compression
machines, and gained a substantial presence globally. These new generation Absorption Chiller-Heaters
offer even greater economies, eco-friendliness and various additional benefits further enriching and
expanding their usage.
C
h
i
l
l
e
r
Capacity
are available in the range of 75 - 1150
Nominal USRT ( 265 kW - 4025 kW ), and can
achieve chilled water temperature upto 3.5 °C
(38.3°F).
EcoChill N
Multi - fuel Capability
EcoChill N can use various type of liquid and
gaseous fuels like Light Oil, SKO (Superior
Kerosene Oil), Natural gas, CNG, LPG and other
gaseous fuels.
Auto De-crystallisation
EcoChill N
are provided with the unique auto
d e - c r y s t a l l i z a t i o n c i rc u i t t o e l i m i n a t e
crystallisation.
Sturdy and Reliable Generator Design
EcoChill N have rugged generator, designed to
handle gaseous fuels as well as light liquid fuels.
On-Line Purging
The factory mounted and tested purging unit
consists of an electrical motor driven purge pump,
storage tank, necessary piping and valves. Any
non-condensable gas generated in the ChillerHeater during operation, is purged continuously
into the storage tank, thereby maintaining low
vacuum in the shell.
Monobloc Burners
Crossover Piping
use monobloc burners of Modulating
type. Gas burners are provided with standard gas
train.
EcoChill N
Crossover pipe is factory installed avoiding the
work at site or at rigger's yard and hence
maintaining high quality of work.
Gravity Feed System
EcoChill N use gravity feed, non-pressurised
super-spraying system, for spraying refrigerant
and absorbent. The use of nozzles is avoided as
they have problems of clogging and wear & tear.
PLC based Control Panel
EcoChill N
are provided with PLC based control
panel with 4 line display, user friendly interface
and data-logging system.
Isolation Valves for Pumps
Side Exit Nozzles
The absorber, evaporator and condenser headers
are provided with side nozzles for ease of
maintenance and lower down-time. The absorber
and condenser headers are hinged type, for easy
access to the tube bundle and eliminates need for
heavy lifting arrangements.
H
e
Isolation valves provided on the pumps, facilitate
on-line pump maintenance, without breaking the
vacuum in the Thermax Absorption Chiller-Heater.
Corrosion Inhibitors
Thermax uses the new generation corrosion
inhibitor, Lithium Molybdate, which is more
effective than conventionally used Lithium Nitrate
and Lithium Chromate.
a
t
e
r
Optional Features & Benefits
VFD Control for excellent Part Load Performance
During part load conditions, modulation of the
absorbent pump by VFD control, allows optimum
flow of the absorbent to the high temperature
generator. This in turn optimises the input energy,
resulting in superior part load performance.
Online standby Canned Motor Pumps
When specified, Thermax can offer on-line standby
solution and refrigerant pumps.
On-line bearing monitoring
As a special option Thermax can provide a TRG meter
for on-line bearing monitoring of the pumps. By
continuously measuring the bearing clearance,
through eddy currents, the TRG reading proactively
lets the user know the condition of the bearing at any
given instant.
Special tube material for Evaporator / Absorber /
Condenser
The selection of tube material is done purely on the
basis of the water quality available at the jobsite.
Accordingly, Thermax can offer following special
tube materials :
· CuNi (95:5) · CuNi (90:10) · CuNi (70:30) · SS - 316
L · Titanium
Dual Firing Burners
For flexibility in use of use of fuel, Thermax can
provide burners which can fire either on Gas or Oil.
Low NOX Burner
As a special feature, Thermax can provide Low NOX
burner.
Standard 90 ppm (can also provide 20 ppm and
lower).
Multi - sectional Shipment Arrangement
For convenience of shipping and rigging, the
Absorption Chiller-Heaters can be shipped in two or
more sections depending upon the site
requirements. This is particularly convenient for
retrofit jobs.
Factory Performance Test
After assembly, Absorption Chiller-Heater can be
individually tested for performance at the
conditions specified by the customer.
During Performance Test, readings are taken for
various parameters like (Testing is done on oil):
· Chilled water inlet / outlet temperatures ·
Capacity · Oil Consumption · Cooling water inlet /
outlet temperatures
Controls
Improved Reliability
Incorporates a state-of-the-art programmable logic controller,
which incredibly enhances the flexibility and reliability of the
machine.
Elaborate Diagnostic Facility
Information such as Chiller-Heater trip causing sensor error,
hardware related faults, pump errors , etc. are recorded and
displayed. These helps in faster and easier trouble shooting and
routine maintenance.
Easier Operation and Maintenance
Unique display screen, feather touch key pad and the software
constitute a user friendly operator interface. The operator can
easily control functions with self explanatory messages displayed
automatically on the screen. Any abnormality is communicated
through an audio visual alarm making it easer to initiate necessary
action.
Data Acquisition and Logging with Adjustable Sampling Time
Also available as optional feature
e-reach (Remote Access for Chillers)
Modem Connectivity
PC Connectivity
DCS / BAS / BMS Connectivity
e
TM
REMOTE ACCESS FOR CHILLERS
Safeties
Antifreeze Protection
! L-cut refrigerant pump
! Antifreeze thermostat
! Chilled water flow switch
! Chilled water DP switch
Crystallisation Free
! HT Generator temperature cutout
! Cooling water low temperature
cutout
Pump Cavitation Safety
! Absorbent pump level relay
! Refrigerant pump level relay
Alarm Cycle
! Dilution cycle alarm
! Total shutdown alarm
Motor Protection
! Absorbent pump overload
relay
! Refrigerant pump overload
relay
! Purge pump overload relay
World Class Technology for
World Class People
Our customer list spans most of the major industry verticals,
each with its specific requirements and operating parameters.
Hotels
Commercial Centers
Sheraton Towers, Brazil
P T Bali Nirwana, Indonesia
Marriot, USA
Educational Institutes
SUNY, Albany, USA
Monash University, Australia
Roosevelt Magnet School, USA
Pharmaceuticals
Astra Zeneca, U.K.
Pfizer India Ltd.
Boehringer, Germany
Jhonson & Jhonson, USA
BBC Studio, UK
Henry Ford Museum, USA
Bicycle Casino, USA
33rd Precinct NYPD, USA
Super Market
Mundial Super Market, Brazil
Prezuni Super Market, Brazil
Raleys Deptt. Stores, USA
Medical Centers
Royal Free Hospital, UK
VA Medical Center, USA
Gemilli Hospital, Italy
Refineries & Petrochemicals
Chemicals
Exxon Mobil, Saudi Arabia
Asian Paints, India
Eka Chemicals, Brazil
Lyondell Equistar
Chemicals, USA
Saudi Formaldehyde and
Chemicals, Saudi Arabia
Reliance Industries Ltd., India
Gas Authority of India Ltd.
Electronics
Bosch, Germany
Moser Baer, India
Temic Heilbronn, Germany
Dairy & Confectionary
Nestle, Philippines
Cadbury, Nigeria
Chitale Dairy, India
Engineering
Steel
Daimler Chrysler, Germany
Larsen & Tubro, India
SKF Bearing, India
Medway Plastics, USA
United Gulf Steel, U.A.E.
Bhilai Steel Plant, India
Rourkela Steel Plant, India
Installations
Minds at work
In 2000, when the State University of New York (SUNY) at Albany was considering
replacing it’s 25 year old single stage Absorber, we approached them with a very
efficient solution. Our two stage high temperature hot water fired chillers enabled
SUNY to now generate the same chilling capacity 1500 TR (5274 kW) with half the
heat input. This means a straight saving of close to 50% in the cost of chilled water.
And of course, the new generation Two stage Absorbers do not compromise on
reliability, as compared to a single stage. 4 levels of safeties against crystallisation
make the units ideal for 24 x 7 operating condition.
Silence Please... Hospital ahead
Reliability of equipment is always the first criteria, when it comes to selecting an
equipment for Hospitals. Air-conditioning is mandatory and a continuous requirement
in some parts of the hospital. In 2000, these factors played an important role in the
decision making at the Veterans Admin. (VA) medical facility at Rhode Island. Three
180 TR (633 kW) two stage steam Absorbers were installed for the critical application
at this facility. Although the plant room is one level below ground, rigging was made
easy by the conveniently sized modules in which the chillers were shipped.
Capacity Expansion without extra power demand
Torrent Pharma, a large integrated pharmaceutical company in India, after detailed
evaluation of both electrical and vapour absorption technologies, adopted Thermax
Absorption Chiller technology. 770 NTR (2700 kW) X 3 Nos. Prochill Absorption
Chiller were installed considering the minimum power requirement and lesser
operating cost of these machines. To maximise the benefits Thermax also
introduced VFDs in the system. The power thus saved was utilised by Torrent
towards capacity expansion.
Safety and Security
NYPD’s 33rd Precinct : When the City of New York built this new Police Precinct
uptown Manhattan, Two Gas fired Absorption Chillers, 150 TR (527 kW)each were a
natural choice giver the low summer time gas cost as compared to the high electric
tariff. After seeing through two summers, NYPD is pleased with the saving in running
cost and also the ease of maintenance and operation.
The Power of Knowledge
Roosevelt Magnet School, MA being very concerned about maintenance and down
time of their chillers, selected two 180 TR (633 kW)Gas fired Absorption Chillers for
their campus in 1999. In addition to easier and pre-planned maintenance schedules,
they are also seeing the benefits in running cost reduction.
Beating the heat at BBC
When the world’s premium television center, BBC, launched a survey to reduce
its energy cost and the environmental degradation, they chose to go in for a
Combined Heating, Power and Cooling System. After a thorough appraisal of
product performance, compatibility with specifications, delivery time and back
up services, BBC along with their consultants unanimously decided to award
the contract to Thermax.
The stroke of a Genius
The cold and wet climate of London requires the heating of air to keep
temperatures up. The National Portrait Gallery at Trafalgar Square found that
their boilers could meet both heating and cooling demands. They opted for a
125 TR (440 kW) Thermax Absorption Chiller, which uses steam from the
boilers and are also environment friendly as they are CFC free. Today, Thermax
Chillers cool the most famous faces housed in the Gallery.
Customer Care
Thermax Absorption Cooling Division has a global network to
ensure quick response to customers. The network consists of
over 100 highly trained Absorption Chillers service personnel.
With a cumulative service experience of close to 2500
Absorption Chillers operating for more than 15 years in over 40
countries, Thermax service personnel are equipped to deliver
the right solution to the users. Thermax has developed specific
service modules for different types of users depending on their
usage pattern, conforming to our proactive approach.
For the benefit of its customers
Thermax offers various value added services like :
e-reach (Remote Access for Chillers)
·
· Preventive maintenance contract
· Operations & Manning (O & M)
· Localised customer training programs.
e
TM
REMOTE ACCESS FOR CHILLERS
Global Quality Standards
LISTED
Thermax Absorption Chillers are exported to more than 40
countries worldwide. Our quality standards are confirmed by the
fact that over the years we have installed many chillers in USA,
Germany, UK, Spain, Italy, Middle East and South East Asia, with
the equipments conforming to the respective country standards
— ISO 9001:2000, ISO 14001, ETL, CE, PED, TUV, DNV, ASME
to name a few. They even conform to the Kyoto Protocol and are
in absolute tandem with Clean Development Mechanisms Code
(CDM) which is becoming the order of times.
S
ISO 14001
A critical parameter in our Quality assurance processes is testing
procedures to ensure vacuum tightness. The tests include :
REGISTERED
FIRM
QMS
THE CITY OF
NEW YORK
DEPARTMENT OF BUILDINGS
164-02-E
A C C R E D I T E D
ANSI* RAB
! Nitrogen test at 18.5 psig (1.3 kg/cm2g) pressure on the shell
side.
! Helium Spray test.
! Helium Shroud test.
EcoChill N
Cooling Cycle
Double Effect Direct Fired Chiller-Heater
HIGH TEMPERATURE
EXHAUST GAS
GENERATOR
LTG
CONDENSER
Coolng
WATER OUTLET
DRAIN HEAT
EXCHANGER
CHILLER WATER
OUTLET
EVAP
ABSORBER
PURGE DEVICE
EVAP
CHILLED WATER
INLET
REF BLOWDOWN
VALVE
S
BURNER
SOLENOID VALVE
HIGH TEMPERATURE
HEAT EXCHANGER
REFRIGERANT PUMP
ABSORBENT PUMP
Cooling
WATER INLET
CONCENTRATED ABSORBENT
PURGE
PUMP
REFRIGERANT
OVER FLOW PIPE
DILUTED ABSORBENT
LOW TEMP HEAT EXCHANGER
VAPORIZED REFRIGERANT
INTERMEDIATE ABSORBENT
Heating Cycle
Double Effect Direct Fired Chiller-Heater
HIGH TEMPERATURE
GENERATOR
EXHAUST GAS
LTG
CONDENSER
DRAIN HEAT
EXCHANGER
HOT WATER
OUTLET
ABSORBER
EVAP
PURGE DEVICE
EVAP
HOT WATER
INLET
REF BLOWDOWN
VALVE
S
BURNER
SOLENOID VALVE
HIGH TEMPERATURE
HEAT EXCHANGER
REFRIGERANT PUMP
ABSORBENT PUMP
CONCENTRATED ABSORBENT
PURGE
PUMP
REFRIGERANT
OVER FLOW PIPE
LOW TEMP HEAT EXCHANGER
DILUTED ABSORBENT
VAPORIZED REFRIGERANT
INTERMEDIATE ABSORBENT
Fuel Driven Absorption
EcoChill N
MAKE UP
WATER
BLOW
DOWN
Light Oil Fired
TO CHIMNEY
COOLING TOWER
COOLING WATER OUTLET
TECHNICAL SYSTEM P & I DIAGRAM
TI
PI
N7
N5
PI
TI
OIL FROM STORAGE TANK
N2
CHILLED/HEATING WATER OUTLET
LSH
PI
FM
SERVICE
TANK
TI
I
LSL
N1
LEGENDS
CHILLED/HEATING WATER INLET
TI
N8
GATE VALVE (OPEN)
GATE VALVE (CLOSE)
GLOBE VALVE (OPEN)
N4
GLOBE VALVE (CLOSE)
PI
VAPOUR ABSORPTION CHILLER HEATER
OIL FIRED
TI
COCK
For reference only
FM
GAS REGULATOR
COOLING WATER INLET
PI
S
AIR SUPPLY FROM
COMMON HEADER.
PI
PI
M
PI
M
NON RETURN VALVE
THREE WAY CONTROL VALVE
BUTTERFLY VALVE (OPEN)
STORAGE
TANK
PI
M
BUTTERFLY VALVE (CLOSE)
PI
"Y'' STRAINER
OIL PUMP
COOLING WATER PUMPS
(1 WORKING + 1 STD BY)
MANUAL OIL VALVE
FILTER 40 MESH
GOVERNOR
SOLENOLD VALVE
FAST ACTING VALVE
Gas Fired
MONO BLOCK BURNER
MAKE UP
WATER
BLOW
DOWN
TO CHIMNEY
COOLING TOWER
COOLING WATER OUTLET
FILTER 40 MECH
PI
ELECTRIC HEATER
THERMOSTAT
AIR FILTER REGULATOR
N7
TI
N5
PI
CENTRIFUGAL PUMP
TI
N2
M
CHILLED/HEATING WATER OUTLET
MOTOR
PNEUMATIC LINE
FM
PI
TI
N1
CHILLED/HEATING WATER INLET
N8
N4
NATURAL GAS
PI
TI
VAPOUR ABSORPTION CHILLER HEATER
GAS FIRED
PI
PI
M
For reference only
COOLING WATER PUMPS
(1 WORKING + 1 STD BY)
COOLING WATER INLET
PI
M
FM
S
AIR SUPPLY FROM
COMMON HEADER.
PI
PI
PI
P
T
F
I
R
C
-
PRESSURE
TEMPERATURE
FLOW
INDICATOR
RECORDER
CONTROLLER
A
L
M
L
S
-
ALARM
LEVEL
HIGH
LOW
SWITCH
CLIENT
SCOPE
THERMAX
SCOPE
Fuel Driven Absorption
EcoChill N
TECHNICAL SPECIFICATION
TR
m3/hr
#
mWC
mmNB
m3/hr
°C
#
#
mWC
mmNB
Nm3/hr
kg/hr
mm
mm
mm
x 1000 kg
x 1000 kg
mm
kW(A)
kW(A)
kW(A)
kW(A)
GD20A CX
OD20A CX
111
61.0
3
4.8
100
111
34.6
3
1
3.9
150
29.7
26.2
3200
2600
2660
5.9
6.5
2400
1.1 (3.4)
0.3 (1.4)
0.75 (1.9)
0.75 (1.7)
GD20B CX
OD20B CX
130
71.5
3
5.7
100
130
34.6
3
1
3.8
150
34.4
30.3
3200
2600
2660
6.2
6.7
2400
1.1 (3.4)
0.3 (1.4)
0.75 (1.9)
0.75 (1.7)
kVA
7.4
7.4
mmNB
200
200
Model Number
Units
Cooling Capacity
Flow rate
Chilled Water
No. of passes (Evaporator)
Circuit
Friction loss
Connection Diameter
Flow rate
Outlet Temp
Cooling Water
No. of passes (Absorber)
Circuit
No. of passes (Condensor)
Friction loss
Connection Diameter
Gas Consumption
Fuel Circuit
Oil Consumption
Overall
Length
Dimension
Width
Height
Max. Shipping Weight
Operating Weight
Clearance for Tube Removal
Absorbent Pump Motor Rating
Refrigerant Pump Motor Rating
Purge Pump Motor Rating
Electric Supply
Burner
Burner Type
Total Electric Input
Power Supply
Exhaust Gas Duct Size
Model Number
Units
Cooling Capacity
TR
m3/hr
#
mWC
mmNB
m3/hr
°C
#
#
mWC
mmNB
Nm3/hr
kg/hr
mm
mm
mm
x 1000 kg
x 1000 kg
mm
kW(A)
kW(A)
kW(A)
kW(A)
Flow rate
Chilled Water
No. of passes (Evaporator)
Circuit
Friction loss
Connection Diameter
Flow rate
Outlet Temp
Cooling Water
No. of passes (Absorber)
Circuit
No. of passes (Condensor)
Friction loss
Connection Diameter
Gas Consumption
Fuel Circuit
Oil Consumption
Overall
Length
Dimension
Width
Height
Max. Shipping Weight
Operating Weight
Clearance for Tube Removal
Absorbent Pump Motor Rating
Refrigerant Pump Motor Rating
Purge Pump Motor Rating
Electric Supply
Burner
Burner Type
Total Electric Input
Power Supply
Exhaust Gas Duct Size
GD 40C CX GD 50A CX
OD 40C CX OD 50A CX
452
505
248.5
277.7
2
2
8.3
7.3
150
200
452
505
34.6
34.6
2
2
1
1
7.0
7.2
250
250
120
134
105.7
118.0
4870
5100
3200
3450
3050
3300
14.6
17.5
16.3
19.3
4100
4100
3(8)
3.7 (11)
0.3 (1.4)
0.3 (1.4)
0.75 (1.9) 0.75 (1.9)
3 (6.1)
3.7 (7.4)
kVA
13.8
16.9
mmNB
300
400
GD20C CX GD20D CX GD30A CX GD30B CX GD30C CX GD40A CX
OD20C CX OD20D CX OD30A CX OD30B CX OD30C CX OD40A CX
162
192
241
272
321
360
89.1
105.6
132.5
149.6
176.5
197.9
2
2
2
2
2
2
6.3
8.0
5.9
6.7
10.0
7.1
100
100
150
150
150
150
162
192
241
272
321
360
34.6
34.6
34.6
34.6
34.6
34.6
2
2
2
2
2
2
1
1
1
1
1
1
4.6
4.7
4.5
4.6
7.1
6.6
150
150
200
200
200
250
43.6
51.1
64
72
85
96
38.4
45.0
56.4
63.4
74.8
84.5
4000
4000
4140
4140
4750
4870
2600
2600
2850
2850
2950
3200
2660
2660
2850
2850
2850
3050
7.2
7.41
9.8
10.1
11.35
13.5
7.8
8.2
10.8
11.2
12.5
15.0
3755
3755
3815
3815
4100
4100
2.2 (6)
2.2 (6)
2.2 (6)
2.2 (6)
2.2 (6)
3(8)
0.3 (1.4)
0.3 (1.4)
0.3 (1.4)
0.3 (1.4)
0.3 (1.4)
0.3 (1.4)
0.75 (1.9) 0.75 (1.9) 0.75 (1.9) 0.75 (1.9) 0.75 (1.9) 0.75 (1.9)
0.75 (1.7) 0.75 (1.7)
1.1 (2.5)
1.1 (2.5)
3 (6.1)
3 (6.1)
HI / LOW (MODULATING BURNER AVAILABLE ON REQUEST)
9.3
9.3
9.8
9.8
12.40
13.8
415 V(±10%), 50 Hz(±5%), 3 Phase+N
200
200
250
250
250
300
GD40B CX
OD40B CX
408
224.3
2
7.5
150
408
34.6
2
1
6.7
250
108
95.1
4870
3200
3050
14.0
15.6
4100
3(8)
0.3 (1.4)
0.75 (1.9)
3 (6.1)
GD 50B CX GD 60A CX GD 60B CX GD 60C CX GD 60D CX GD 70A CX
OD 50B CX OD 60A CX OD 60B CX OD 60C CX OD 60D CX OD 70A CX
560
636
709
802
890
993
307.9
349.7
389.8
441.0
489.3
546.0
2
3
3
2
2
2
7.7
6.8
7.3
4.8
5.2
5.1
200
250
250
250
250
250
560
636
709
802
890
993
34.6
34.6
34.6
34.6
34.6
34.6
2
2
2
1
1
2
1
1
1
1
1
1
7.5
7.7
7.9
5.4
5.7
12.8
250
300
300
300
300
350
149
168
187
213
236
262
131.2
147.9
164.6
187.5
207.8
230.7
5100
6700
6700
7900
7900
7900
3450
3700
3700
3900
3900
4100
3300
3400
3400
3400
3400
4000
18.0
26.5
27.2
31.5
33.1
40.5
20.0
29.6
30.5
34.8
36.9
45.3
4100
5320
5320
6560
6560
6560
3.7 (11)
5.5 (14)
5.5 (14)
5.5 (14)
5.5 (14)
6.6 (17)
0.3 (1.4)
0.3 (1.4)
0.3 (1.4)
1.5 (5)
1.5 (5)
1.5 (5)
0.75 (1.9) 0.75 (1.9) 0.75 (1.9) 0.75 (1.9) 0.75 (1.9) 0.75 (1.9)
3.7 (7.4)
4 (8)
4 (8)
7.5 (14.4) 7.5 (14.4) 11 (21.6)
HI / LOW (MODULATING BURNER AVAILABLE ON REQUEST)
16.9
19.4
19.4
26.5
26.5
33.8
415 V(±10%), 50 Hz(±5%), 3 Phase+N
400
400
400
450
450
500
GD 70B CX
OD 70B CX
1107
608.6
2
5.6
250
1107
34.6
1
1
6.0
350
292
257.1
7900
4100
4000
42.0
46.9
6560
6.6 (17)
1.5 (5)
0.75 (1.9)
11 (21.6)
NOMENCLATURE - G/O=Gas / Oil • D=Double Effect • 20, 30...=Frame Size • A, B, C...=Model No. • C=Chiller-Heater • X=High CoP • S=Side Arm Heat Exchanger.
• Cooling water inlet temperature = 29.4°C • Rated current for Purge pump =1.9 A and Control panel = 1.5 A • Minimum Cooling water inlet temperature is 10°C
• Maximum Allowable pressure in chilled / cooling water system =8 kg/cm2(g) • G.C.V. for Gas = 9650 kcal/Nm3 • G.C.V. for Oil = 10960 kcal/kg
• All Nozzle connections to suit ASME B16.5 Class 150 • Ambient condition shall be between 5 to 45°C • Technical specification is based on ARI 560
13.8
300
33.8
500
Applications
> Hi-Tech Insulation
> Chemicals
manufacturing
> Commercial Centers
> Furniture
> Educational Institutes
Sustainable Solutions in
Energy & Environment
Manufacturing
> Electronics
Cooling & Heating Division
> Hospitals
> Hotels
> Aquariums
> Medical Centers
> Office Buildings
> Paper & Pulp
> Casinos
> Petrochemicals
> Plastics
> Pharmaceuticals
> Bottling Plants
> Textiles
> Wineries
> Super Markets
Thermax Ltd, INDIA
D-13 MIDC, R.D.Aga Road,
Chinchwad, Pune 411 019, India.
Tel.: +91-20-2747 5941
Fax: +91-20-2747 5907
Email: [email protected]
Thermax Inc., USA
40440 Grand River Avenue,
Novi Michigan 48375, U.S.A
Tel: 00-1-248-4743050 Mob : 714-393-1628
Fax: 00-1-248-4745790
Email: [email protected],
[email protected]
Thermax Europe Ltd, U.K.
Tel : 00-44-1582-727756 Fax : 00-44-1582-731538
Email : [email protected]
www.thermax-europe.com
Thermax Hong Kong Ltd
Tel : (852) 2584 6199 Fax : (852) 2584 6133
Email : [email protected]
www.thermax-china.com
Thermax Rus Ltd, Russia
Tel : 00-7095-935049/91 Fax : 00-7095-1347410
Email : [email protected]
Thermax Ltd, U.A.E.
Tel : 00-971-4-8816481 Fax : 00-971-4-8816039
E-mail : [email protected]
Thermax Ltd, Saudi Arabia
Tel : 00-966-3-857-5056 Fax : 00-966-3-857-5068
Email : [email protected]
Thermax Ltd, Kenya
Tel : 00-254-20-4440233 Fax : 00-254-20-4451919
Email : [email protected]
Thermax Ltd, Thailand
Tel : 00-66-02-381-5423 Fax : 00-66-02-381-8987
Email : [email protected]
Thermax do Brasil
Tel : +5521-2516 9227 Fax : +5521-2516 9226
Email : [email protected]
www.thermaxdobrasil.com.br
Thermax Ltd, Malaysia
Tel : 00-60-3-2166 9801 Fax : 00-60-3-2166 9802
Email : [email protected]
Thermax Ltd, Bangladesh
Telefax : 008802-9885823 Mob : 0088011808001
Email : [email protected]
Thermax Ltd. Srilanka
Tel : 00-9411-4407969 Fax : 00-9411-2533217
Email : [email protected]
Worldwide Network
Russia
U.K.
China
U.S.A
Saudi Arabia
Nigeria
Brazil
U.A.E.
Kenya
Bangladesh
Hong Kong
India Thailand
Malaysia
Srilanka
Indonesia
Australia
www.thermaxindia.com
Thermax Business Portfolio
Absorption Cooling
Air Pollution Control
Boilers & Heaters
Distributor / Agent
synergy design
July 2006 Edition
In view of our constant endeavour to improve the quality of products, we reserve the right to
amend any product details & contents of this literature without prior notice.
Captive Power
Chemicals
Water & Waste Solutions
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement