Product Brochure Eaton 5P Tower UPS Enterprise class battery backup in a space-saving tower design for network closets and computer rooms. Space-saving: The Eaton 5P tower provides premium Intelligent Power Software Suite protection while conserving value space in multiple, slim tower designs. By integrating the software with the Eaton 5P, you can: Efficiency: The 5P provides industry leading efficiency of • up to 99 percent. Manageability: •UPSmanagement: By integrating Eaton’s free Intelligent Power® Software Suite, you can monitor and manage the power devices on your network. •Energymetering:The 5P meters energy consumption at the UPS level. LCD display: Eaton’s next-generation LCD offers a • • Seamlessly integrate with VMware’s vCenter Server™ virtualization management solution, as well as virtualization platforms such as Citrix® XenServer, Microsoft SCVMM™, Red Hat® and other Xen® open source platforms Initiate live migration of virtual machines (VM) to automatically and transparently migrate VMs during power disruptions to unaffected devices with systems such as VMware vMotion™ and Microsoft Live Migration Execute graceful shutdown of computers and virtual machines/servers during an extended power outage graphical interface which provides all critical UPS information in a single screen view. To learn more, please visit: Eaton.com/intelligentpower More power: The 5P protects more devices by providing 20 percent more wattage compared to traditional UPSs. Services and support Battery life: Eaton’s exclusive ABM® technology increases battery service life by 50 percent. ENERGY STAR®: 5P 2200 and 3000 VA tower models are ENERGY STAR® qualified. ENERGY STAR helps consumers save money and protect the environment through energy efficient products and practices. Eaton provides product support 24 hours a day, 7 days a week. From battery replacement to full UPS service plans, Eaton has one of the top service models in the industry. Three-year warranty The 5P warranty covers both the UPS and the batteries for three years. No other manufacturer in the industry offers as comprehensive a warranty. 5P TOWER MODEL SELECTION GUIDE* Catalog number Rating (VA/watts) Input connection Output receptacles Dimensions (H x W x D), in Net weight, lb 5P750 750/600 5-15P (8) 5-15R 9.1 x 5.9 x 13.6 22.7 5P1000 1000/770 5-15P (8) 5-15R 9.1 x 5.9 x 13.6 24.4 5P1500 1440/1100 5-15P (8) 5-15R 9.1 x 5.9 x 17.5 35.3 5P2200 1950/1920 5-20P (4) 5-20R, (4) 5-15R 3.4 x 17.4 x 20.6 65.0 5P3000 3000/2700 L5-30P (6) 5-20R, (1) L5-30R 3.4 x 17.4 x 25.4 87.0 Tower 120V 50/60 Hz models Tower 208 or 230V 50/60 Hz models 5P850G 850/600 C14 (6) C13 9.1 x 5.9 x 13.6 21.9 5P1550G 1550/1100 C14 (8) C13 9.1 x 5.9 x 17.5 35.2 *Duetocontinuousproductimprovementprograms,allspeciicationsaresubjecttochangewithoutnotice.PleasevisitEaton.com/5Ptoviewcompleteandupdatedproductspeciications. Additional options Connectivity Network Card-MS Relay / Serial Interface Card Environmental Monitoring Probe What’s in the box Catalog number For use with NETWORK-MS All models RELAY-MS All models 116750224-001 All models (requires Network Card-MS) 5P750 rear panel •UsermanualCD •IntelligentPower SoftwareSuiteCD •Quickstartguide •USBcable •RS-232cable G models only •2IEC-to-IECjumper cables 2200/3000 models only •Towerpedestalsand Phillipsheadscrew driver 5P2200 rear panel Communication slot with optional network card Communication slot with optional network card RS-232 port USB port Remote power off/Remote on-off connector (8) 5-15R output receptacles RS-232 port USB port Two individually controlled groups of outlets Remote power off/Remote on-off connector Input line cord with 5-15P Input line cord with 5-15P Two individually controlled groups of outlets (8) 5-15R output receptacles To interact with the Eaton 5P Tower UPS, please visit: Eaton.com/5P Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com Powerquality.eaton.com ©2013 Eaton All Rights Reserved Printed in USA BR153008EN May 2013 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners. ENERGY STAR and the ENERGY STAR mark are registered U.S. marks. ENERGY STAR is a registered mark owned by the U.S. government. Product Brochure Eaton 5P Rackmount UPS Enterprise class battery backup for network closets and small data centers. Flexibility: The Eaton 5P is available in space saving 1U and 2U rackmount configurations. Intelligent Power Software Suite Efficiency: The 5P provides industry leading efficiency of • By integrating software with the Eaton 5P, you can: up to 99 percent. Manageability: •UPSmanagement: By integrating Eaton’s free Intelligent Power® Software Suite, you can monitor and manage the power devices on your network. •Energymetering:The 5P meters energy consumption at the UPS level. LCD display: Eaton’s next-generation LCD offers a graphical interface which provides all critical UPS information in a single screen view. More power: The 5P protects more devices by providing • • Seamlessly integrate with VMware’s vCenter Server™ virtualization management solution, as well as virtualization platforms such as Citrix® XenServer, Microsoft SCVMM™, Red Hat® and other Xen® open source platforms Initiate live migration of virtual machines (VM) to automatically and transparently migrate VMs during power disruptions to unaffected devices with systems such as VMware vMotion™ and Microsoft Live Migration Execute graceful shutdown of computers and virtual machines/servers during an extended power outage To learn more, please visit: Eaton.com/intelligentpower 20 percent more wattage compared to traditional UPSs. Services and support Battery life: Eaton’s exclusive ABM® technology increases Eaton provides product support 24 hours a day, 7 days a week. From battery replacement to full UPS service plans, Eaton has one of the top service models in the industry. battery service life by 50 percent. ENERGY STAR®: 5P 2U rackmount models are ENERGY STAR® qualified. ENERGY STAR helps consumers save money and protect the environment through energy efficient products and practices. Three-year warranty The 5P warranty covers both the UPS and the batteries for three years. No other manufacturer in the industry offers as comprehensive a warranty. 5P RACKMOUNT MODEL SELECTION GUIDE* Catalog number Rating (VA/watts) Input connection Output receptacles Dimensions (H x W x D), in Net weight, lb 65.0 2U Rackmount, 120V, 50/60 Hz models** 5P1500RT 1440/1440 5-15P (8) 5-15R 3.4 (2U) x 17.4 x 20.6 5P2200RT 1950/1920 5-20P (4) 5-15R, (4) 5-20R 3.4 (2U) x 17.4 x 20.6 65.0 5P3000RT 3000/2700 L5-30P (3) 5-15R, (3) 5-20R, (1) L5-30R 3.4 (2U) x 17.4 x 25.4 87.0 1U Rackmount, 120V, 50/60 Hz models 5P550R 550/420 5-15P (5) 5-15R 1.7 (1U) x 17.2 x 14.3 17.8 5P750R 750/600 5-15P (5) 5-15R 1.7 (1U) x 17.2 x 20.0 30.6 5P1000R 1000/770 5-15P (5) 5-15R 1.7 (1U) x 17.2 x 20.0 32.5 5P1500R 1440/1100 5-15P (5) 5-15R 1.7 (1U) x 17.2 x 21.8 43.5 1U Global Rackmount, 208/230V, 50/60 Hz models 5P850GR 850/600 C14 (4) C13 1.7 (1U) x 17.2 x 20.0 30.4 5P1550GR 1550/1100 C14 (6) C13 1.7 (1U) x 17.2 x 21.8 42.7 *Duetocontinuousproductimprovementprograms,allspeciicationsaresubjecttochangewithoutnotice.PleasevisitEaton.com/5Prmtoviewcompleteandupdatedproductspeciications. **CatalognumbersthatendinRTcanbeusedinbothrackmountortowerconigurations. Options Connectivity Network Card-MS Relay / Serial Interface Card Catalog number For use with NETWORK-MS All models What’s in the box RELAY-MS All models 116750224-001 All models (requires Network Card-MS) 1U two-post rail kit (optional) RK2PA All 1U models except 5P550R 2U two-post rail kit (optional) 103007018-5591 All 2U models EHBPL1500R-PDU1U 5P550R, 5P750R, 5P1000R, 5P1500R, 5P1500RT EHBPL2000R-PDU1U 5P2200RT EHBPL3000R-PDU1U 5P3000RT Environmental Monitoring Probe Mounting hardware Power distribution & bypass HotSwap Maintenance Bypass (MBP) TheHotSwapMaintenance Bypassallowsyoutoexchangeor servicetheUPSwithoutshutting downtheconnectedload 5P 2U rear panel •UsermanualCD •Towerpedestals •IntelligentPower (2Umodelsonly) SoftwareSuiteCD •Phillipsheadscrew •Quickstartguide driver(2Umodelsonly) •Four-postrailkit G models only (5P550Rearsonly) •2IEC-to-IECjumper •Extrawallmountingear cables (5P1500R&5P1550GR) •Outputcablelocking •USBcable system •RS-232cable •Inputcablelocking system 5P 1U rear panel 5-15P input plug RS-232 port Communication slot with optional network card (8) 5-15R output receptacles USB port Remote power off/Remote on-off connector Two individually controlled groups of outlets USB port RS-232 port Remote power off/Remote on-off connector (5) 5-15R output receptacles Two individually controlled groups of outlets Communication slot with optional network card To interact with the Eaton 5P rackmount UPS, please visit: Eaton.com/5Prm Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com Powerquality.eaton.com ©2013 Eaton All Rights Reserved Printed in USA BR153009EN May 2013 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners. ENERGY STAR and the ENERGY STAR mark are registered U.S. marks. ENERGY STAR is a registered mark owned by the U.S. government. Product Brochure Eaton 5PX UPS Enterprise class battery backup with extended runtime designed for virtualized environments. 5PX features and benefits: Extended Runtime: Add up to four extended battery modules for maximum runtime. Virtualization-ready: Available in convenient bundles with a network card and management software to make going virtual simple. Efficiency: Provides industry leading efficiency of up to 99 percent. Manageability: • Energymetering: The 5PX meters energy consumption right down to the outlet segments. No other UPS in the industry offers this capability. • UPSmanagement:By integrating Eaton’s free Intelligent Power® Software Suite, you can monitor and manage the power devices on your network. LCD display: Eaton’s next generation LCD offers a graphical interface which provides all critical UPS information in a single screen view. More power: Protects more devices by providing 28 percent more wattage compared to traditional UPSs. Battery life: Eaton’s exclusive ABM® technology increases battery service life by 50 percent. Intelligent Power Software Suite By integrating the suite with the Eaton 5PX, you can: • SeamlesslyintegratewithVMware’svCenterServer™ virtualization management solution, as well as virtualization platforms such as Citrix® XenServer, MicrosoftSCVMM™, Red Hat® and other Xen® open source platforms • Initiatelivemigrationofvirtualmachines(VM)to automaticallyandtransparentlymigrateVMsduring power disruptions to unaffected devices with systems suchasVMwarevMotion™ and Microsoft Live Migration • IntegratewithVMwarevCenterSiteRecoveryManager To learn more, please visit: Eaton.com/intelligentpower Services and support Eaton provides product support 24 hours a day, 7 days a week. From battery replacement to full UPS service plans, Eaton has one of the top service models in the industry. Three-year warranty The 5PX warranty covers both the UPS and the batteries for three years. No other manufacturer in the industry offers as comprehensive a warranty. The Eaton 5PX is an ENERGY STAR® qualified UPS. ENERGY STAR is intended to help consumers save money and protect the environment through energy efficient products and practices. 5PX MODEL SELECTION GUIDE* Catalog Number Rating (VA/Watts) Input connection 120V, 50/60 Hz 5PX1000RT 1000/1000 5-15P 5PX1500RT 1440/1440 5PX2200RT 1950/1920 5-20P 5PX3000RT2U 3000/2700 L5-30P 5PX3000RT3U 208V/230V, 50/60 Hz 5PX1500iRT 1500/1350 C14-10A 5PX2200iRT 2200/1980 C20-16A 5PX3000iRT2U 3000/2700 120V, 50/60 Hz Virtualization-ready bundles with Network Card-MS 5PX1500RTN 1440 / 1440 5-15P 5PX2200RTN 1950 / 1920 5-20P 5PX3000RTN 3000 / 2700 L5-30P 208/230V, 50/60 Hz Virtualization-ready bundles with Network Card-MS 5PX3000iRTN 3000 / 2700 C20 Extended Battery Modules DC voltage For use with 5PXEBM48RT 48V All 1000, 1500 & 2200 models 5PXEBM72RT2U All 3000 2U models 72V 5PXEBM72RT3U All 3000 3U models Output receptacles Dimensions (H x W x D), in (8) 5-15R Net weight, lb 62 65 65 87 86 3.4 x 17.4 x 20.6 (8) 5-20R 3.4 x 17.4 x 25.4 5.1 x 17.4 x 19.6 (1) L5-30R (6) 5-20R (1) C19-16A (8) C13-10A (8) C13-10A 3.4 x 17.4 x 25.4 61 63 84 (8) 5-15R (8) 5-20R (6) 5-20R, (1) L5-30R 3.4 x 17.4 x 20.6 3.4 x 17.4 x 20.6 3.4 x 17.4 x 25.4 65 65 87 (8) C13, (1) C19 Max qty / UPS 3.4 x 17.4 x 25.4 Dimensions (H x W x D), in 3.4 x 17.4 x 20.6 3.4 x 17.4 x 25.4 5.1 x 17.4 x 19.6 84 Net weight, lb 72 102 98 4 3.4 x 17.4 x 20.6 *Due to continuous product improvement programs, all specifications are subject to change without notice. Please visit Eaton.com/5PX to view complete and updated product specifications. Additional Options Connectivity Network Card-MS Environmental Monitoring Probe Power Distribution & Bypass HotSwap Maintenance Bypass (MBP) The HotSwap Maintenance Bypass allows you to exchange or service the UPS without shutting down the connected load Catalog Number For use with What’s in the box NETWORK-MS 116750224-001 All models* All models (requires Network Card-MS) EHBPL1500R-PDU1U All 1000 & 1500 models EHBPL2000R-PDU1U All 2200 models EHBPL3000R-PDU1U All 3000 models 103007018-5591 All models •Towerpedestals •Four-postrailkit •UsermanualCD •IntelligentPowerSoftwareSuiteCD •Quickstartguide •USBcable •RS-232serialcable •PhillipsHeadscrewdriver •2IECtoIECjumpercables (208V/230V models) Mounting Hardware 2-post rail kit * Network Card-MS is included with catalog numbers 5PX1500RTN, 5PX2200RTN, 5PX3000RTN and 5PX3000iRTN. 5PX UPS rear panel (1000 & 1500 VA) RS-232 port USB port EBM battery connector (8) 5-15R output receptacles 5-15P input plug Communication slot with optional Network Card Remote Power Off/ Remote On Off connector EBM RJ-11 connector Site wiring fault indicator Battery runtime You can get up to five hours of battery runtime using the internal batteries and extended battery modules. For a detailed, interactive battery runtime chart, please visit: Eaton.com/5PX - then view the individual technical pages for details of each UPS. Eaton Corporation 8609 Six Forks Road Raleigh, NC 27615 United States 800.356.5794 Two individually controlled and metered groups of outlets To interact with the Eaton 5PX UPS, please visit: Eaton.com/5PX CANADA Ontario: 416.798.0112 Toll free: 1.800.461.9166 Eaton.com/powerquality ©2011 Eaton Corporation All Rights Reserved Printed in USA 5PX01FXA December 2012 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners. ENERGY STAR and the ENERGY STAR mark are registered U.S. marks. ENERGY STAR is a registered mark owned by the U.S. government. Product Brochure Eaton 5SC UPS Affordable and reliable protection for small business servers, storage and network equipment Eaton® 5SC features and benefits: Flexible integration: LCD display: The LCD interface provides clear status • Convenient form factor: The 5SC fits easily into small spaces such as kiosks, cash machines and ticket machines while delivering flexibility with up to eight outlets. • Battery life: Eaton’s exclusive ABM® technology Adjustable input waveform sensitivity: The 5SC is adaptable to specific environments, like genset. increases battery service life by 50 percent with easy front panel battery replacement to extend UPS service life. Intelligent Power Software Suite: of UPS key parameters such as input and output voltage, load and battery level, and estimated runtime. Configuration capabilities are also offered for output voltage, audible alarm and power input sensitivity. Manageability: • USB, serial and relay connectivity: USB port is HID-compliant for automatic integration into Windows, Mac OS and Linux. • Eaton Intelligent Power Manager (IPM): IPM software provides network power management. 5SC is managed over the network through a proxy server having IPP installed. By integrating Intelligent Power Manager and Intelligent Power Protector software with the 5SC, you can: • Get up-to-the-minute information on the status of UPS power locally on your PC or remotely through your PC/server as a proxy • Execute graceful, automatic shutdown of network devices during a prolonged power disruption, preventing data loss and saving work-in-progress • Manage and optimize power performance in your virtual environment and manage your 5SC on the same screen Reliable power protection: • Pure sinewave output: When operating in battery mode, the 5SC provides a high-quality output signal for any sensitive equipment connected. • Buck and boost operation: The 5SC corrects a wide range of input voltage variations through continuous regulation without the use of batteries, and ensures consistent input voltage to the connected equipment. To learn more, please visit: Eaton.com/intelligentpower Eaton 5SC UPS Ideal for protecting: • Tower servers • Network-attached storage (NAS), network equipment • ATMs, ticket machines, kiosks 5SC UPS MODEL SELECTION GUIDE1 Rating Catalog number (VA/watts) Input connection Output receptacles Dimensions (H x W x D), in Net weight, lb 5SC Tower 120V, 50/60 Hz models 5SC500 500/350 5-15P (6 ft) (4) 5-15R 8.2 x 5.9 x 9.4 15.2 5SC750 750/525 5-15P (6 ft) (6) 5-15R 8.2 x 5.9 x 13.4 23.1 5SC1000 1000/700 5-15P (6 ft) (8) 5-15R 8.2 x 5.9 x 13.4 25.6 5SC1500 1440/1080 5-15P (6 ft) (8) 5-15R 8.2 x 5.9 x 16.1 34.0 5SC500G 500/350 C14 (4) C13 8.2 x 5.9 x 9.4 15.0 5SC750G 750/525 C14 (6) C13 8.2 x 5.9 x 13.4 23.1 5SC1500G 1500/1050 C14 (8) C13 8.2 x 5.9 x 16.1 33.5 5SC Tower 230V 50/60 Hz models Services and support Eaton provides product support 24 hours a day, 7 days a week. From battery replacement to full UPS service plans, Eaton has one of the top service models in the industry. Three-year warranty The 5SC warranty covers both UPS and the batteries for three years. No other manufacturer in the industry offers a warranty as comprehensive. What’s in the box • 5SC UPS • USB, serial cable and software • Warranty for connected equipment • User manual and safety instructions G models only • 2 IEC output power cords 2 5SC UPS front panel 5SC750 UPS rear panel Power LCD scroll Alarm silence LCD interface USB port RS-232 port Userreplaceable battery with ABM® technology (6) 5-15R output receptacles 6-foot input line cord with 5-15P (plugs into standard wall socket) 1 Due to continuing product improvement programs, specifications are subject to change without notice. For complete specifications and battery runtimes, visit Eaton.com/5SC. 2 Model 5SC750 To interact with the 5SC UPS, please visit: Eaton.com/5SC Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com Powerquality.eaton.com ©2013 Eaton All Rights Reserved Printed in USA BR153027EN August 2013 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners. Powerware series Eaton 9130 Tower UPS Features • Protectsagainstdowntime,datalossandprocessinterruption byprovidingcontinuous,cleanpower • Expandsmonitoring,managementandcontinuousuptime capabilitieswiththeIntelligentPower®SoftwareSuite—perfect forvirtualizedenvironments Product snapshot • Offerspremiumperformancewitha0.9powerfactorand>95 percentefficiencyinhighefficiencymode Product rating: 700–3000 VA • IncreasesbatteryservicelifeandsystemuptimewithABM® batterychargingtechnology Voltage 120 Vac, 208–240V Frequency: 50/60 Hz (auto-sensing) • Enablesprolongedruntimeofessentialequipmentduring poweroutagesbyallowingfororderly,remoteshutdownof non-criticalsystemsorprocesses Configuration: Tower • Conservesvaluablespacewithaslimtowerdesign • Providesatwo-yearlimitedwarranty,anextendedwarranty anda$250,000loadprotectionguarantee(U.S.andCanada) Advancedpowerprotectionfor: Maximum availability • ITandnetworkingenvironments • ABMtechnologyincreases batterylifeandsystem uptime • Servers,networkinggear • Telecommunications,VoIP,securitysystems • Medicalsystems • Diagnosticsandmedicalscreening • Patientrecordarchives • Manufacturingsystems • Chipfabrication • Pharmaceuticalproduction • Chemicalprocessing • Loadsegmentsallowfor selectiveloadshedding duringoutages • Optionalhot-swappable extendedbatterymodules (EBMs)extendbackup runtimeforhours • Internalhot-swappable batteriescanbereplaced withoutpoweringdown theUPS • UPSstartuponbatterypower • OptionalHotSwap MaintenanceBypass(MBP) enablestheentireUPStobe servicedorreplacedwithout interruptingpowertoloads Low total cost of ownership • Morerealoutputpowerfor dollarspentwith0.9power factor • Cutsenergyusageandcosts with>95%efficiencyratingin highefficiencymode UPS status and operation Communications • Astandardcommunication slotacceptscardsforWeb, SNMP,Modbusorserial connectivity • FreeIntelligentPower SoftwareSuiteforexpanded monitoring,management andshutdowncapabilities (compatiblewithVMware vCenterServer™and MicrosoftSCVMM™) • Connectdirectlytothe Ethernetnetworkandthe Internettomonitorand managetheUPSwitha standardWebbrowser • Bright,frontpanelLCD foreasymonitoringand management Bright LCD user interface • LEDstoshowsystemstatus • Directmonitoringviaexisting managementsystemsand LANs • OptionalFlexPDUadds moreplug-and-play flexibility,streamlining powerdistribution • Monitorpowerconditions inrealtimethrough existingfacilitiesorbuilding managementsystem • Monitorandgracefullyshut downmultipleserversand virtualmachinesrunning variousoperatingsystems • Receivealarmnotifications fromtheUPS,environmental monitoringdevices,security systemsorthroughyour vCenterdashboard Formoreinformation onthe9130,pleasevisit www.eaton.com/9130 orcall800.356.5794. Add up to four EBMs for hours of runtime Extended battery module connection Communication bay Optional FlexPDU and HotSwap MBP for greater flexibility and uptime Standard relay output contact RS-232 port Remote Emergency Power Off (REPO) USB port Line cord with 5-15P Two individually controlled load segments UPS rear panel (PW9130L1500T-XL) 2 EATON CORPORATION Eaton 9130 Tower UPS Battery runtimes (in minutes) Load Internal w/1 (VA/Watts) batteries EBM PW9130L700T 700/490 8 N/A 525/368 12 N/A 350/245 21 N/A 175/123 37 N/A PW9130i700T 700/490 8 N/A 525/368 12 N/A 350/245 19 N/A 175/123 35 N/A PW9130L1000T-XL 1000/700 10 40 750/525 13 58 500/350 24 85 250/175 48 190 PW9130G1000T-XL / PW9130i1000T-XL 1000/700 10 40 750/525 13 55 500/350 22 82 250/175 47 190 PW9130L1500T-XL 1500/1050 7 34 1125/788 11 44 750/525 18 79 375/263 38 167 w/2 EBMs w/3 EBMs w/4 EBMs N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 73 101 172 310 108 152 249 451 149 219 304 569 78 103 186 328 110 151 250 431 150 223 312 584 63 84 148 278 88 129 207 475 135 210 267 540 Load Internal w/1 w/2 (VA/Watts) batteries EBM EBMs PW9130i1500T-XL 1500/1050 7 32 61 1125/788 11 47 83 750/525 18 81 143 375/263 38 171 298 PW9130L2000T-XL 2000/1400 15 61 111 1500/1050 21 81 145 1000/700 34 129 198 500/350 72 225 449 PW9130G2000T-XL / XLEU / PW9130i2000T-XL 2000/1400 15 61 111 1500/1050 21 81 145 1000/700 34 129 198 500/350 72 225 449 PW9130L3000T-XL 3000/2100 9 35 66 2250/1575 13 53 100 1500/1050 22 86 153 750/525 69 168 298 PW9130G3000T-XL / XLEU / PW9130i3000T-XL 3000/2100 9 36 68 2250/1575 12 49 90 1500/1050 20 79 143 750/525 46 161 267 w/3 EBMs w/4 EBMs 98 126 208 416 128 195 262 564 156 184 293 590 194 269 410 766 156 184 293 590 186 248 431 840 95 139 221 395 132 183 267 545 101 134 180 434 137 165 240 547 Notes: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. Runtimes are shown at a 0.7 power factor. 9130 models Catalog number Style number North American models: 120V, 50/60 Hz PW9130L700T 103006426-6591 PW9130L1000T-XL 103006427-6591 PW9130L1500T-XL 103006428-6591 PW9130L2000T-XL 103006429-6591 PW9130L3000T-XL 103006430-6591 Global models: 208V, 50/60 Hz PW9130G1000T-XL 103006431-6591 PW9130G2000T-XL 103006432-6591 PW9130G2000T-XLEU 103006478-6591 PW9130G3000T-XL 103006446-6591 PW9130G3000T-XLEU 103006479-6591 International models: 230V, 50/60 Hz PW9130i700T 103006433-6591 PW9130i1000T-XL 103006434-6591 PW9130i1500T-XL 103006435-6591 PW9130i2000T-XL 103006436-6591 PW9130i3000T-XL 103006437-6591 Extended battery modules PW9130N1000T-EBM4 103006438-6591 PW9130N1500T-EBM5 103006439-6591 PW9130N3000T-EBM6 103006440-6591 (50.0) Rating (VA/Watts) Input connection1 Output receptacles Dimensions H x W x D, in (mm) Weight, lb (kg) 700/630 1000/900 1500/1350 2000/1800 3000/2700 5-15P 5-15P 5-15P 5-20P L5-30P (6)5-15R (6)5-15R (6)5-15R (1)L5-20R,(4)5-20R (4)5-20R,(1)L5-30R 9.1x6.3x13.8(230x160x350) 9.1x6.3x15.0(230x160x380) 9.1x6.3x16.9(230x160x430) 12.8x8.4x16.1(325x214x410) 12.8x8.4x16.1(325x214x410) 26.9(12.2) 32.0(14.5) 41.9(19.0) 76.1(34.5) 76.1(34.5) 1000/900 2000/1800 2000/1800 3000/2700 3000/2700 L6-20P3 L6-20P3 L6-20P3 L6-20P3 L6-20P3 (1)L6-20R,(2)6-20R (1)L6-20R,(4)6-20R (8)C13,(1)C19 (1)L6-30R,(1)L6-20R, (2)6-20R (8)C13,(1)C19 9.1x6.3x15.0(230x160x380) 12.8x8.4x16.1(325x214x410) 12.8x8.4x16.1(325x214x410) 12.8x8.4x16.1(325x214x410) 32.0(14.5) 76.1(34.5) 76.1(34.5) 76.1(34.5) 12.8x8.4x16.1(325x214x410) 76.1(34.5) 700/630 1000/900 1500/1350 2000/1800 3000/2700 C14 C14 C14 C14 C20 (6)C13 (6)C13 (6)C13 (8)C13,(1)C19 (8)C13,(1)C19 9.1x6.3x13.8(230x160x350) 9.1x6.3x15.0(230x160x380) 9.1x6.3x16.9(230x160x430) 12.8x8.4x16.1(325x214x410) 12.8x8.4x16.1(325x214x410) 26.9(12.2) 32.0(14.5) 41.9(19.0) 76.1(34.5) 76.1(34.5) NA NA NA NA NA NA NA NA NA 9.1x6.3x15.0(230x160x380) 9.1x6.3x16.9(230x160x430) 12.8x8.4x16.1(325x214x410) 40.8(18.5) 53.6(24.3) 110.3 1 Input cord length is 6 ft C14, w/detachable L6-20P 3 C20, w/detachable L6-20P 4 This EBM works with 1000 VA model, where available 5 This EBM works with 1500 VA model 6 This EBM works with 2000/3000 VA models, where available 2 Additional notes: Comprehensive Eaton services available for 9130 Tower products • Warranty+extendedwarranties—3or5yearstotal • On-siteserviceplansforstartupsandpreventiveand correctivemaintenance Visitwww.eaton.com/9130fordetails. When high voltage 9130 is used at 208V, derate power by 10% and 20% at 200V When low voltage 9130 is used at 110V, derate power by 10% and 20% at 100V www.eaton.com/powerquality 1.800.356.5794 3 Technical specifications 1 General Userinterface LEDs Topology Diagnostics UPSbypass Dimensions Remote Emergency Power-off(REPO) GraphicalLCDwithbluebacklightandtextin English,French,German,RussianandSpanish Fourstatus-indicatingLEDs Trueonline,double-conversion Fullsystemself-test Automaticbypass Seemodelstable EmergencyshutdowncontrolthroughtheREPOport Electrical input Nominalvoltage Voltagerange Powerdraw ofUPS Dedicatedcircuit breakerrating 120V,208V,220–240V 120V:90–138Vac 208/230V:160–276Vac 700:5.8A@120V,3.4A@208V,3.0A@230V 1000:8.3A@120V,4.8A@208V,4.3A@230V 1500:12.5A@120V,7.2A@208V,6.5A@230V 2000:16.6A@120V,9.6A@208V,8.7A@230V 3000:14.4A@208V,13.0A@230V 120V: 700–1500VA:15A 2000VA:20A 3000VA:30A 208/230V: 700–2000VA:10A 3000VA:16A Frequency 50/60Hz Frequencyrange 45–65Hz Electrical output Powerfactor Onutilityvoltage regulation Onbattery voltageregulation Efficiency Frequency regulation Loadcrestfactor Voltage waveform Loadsegments Battery Batterytype Batteryruntime Battery replacement Start-on-battery Communications Serialport RS-232standard,forinterfacetopower managementsoftware USBport HIDstandard,forcommunicatingwithWindows98, XP,MEandVistacomputers Relayoutput Commonalarmstandard Communications Optionalcommunicationslot(Mini-Slot) slot Optional SNMP/Webcardfordirectcontrolandmonitoring communication inSNMP-basednetworks,monitoringofUPSstatus cards andmetersthroughWebbrowserinterfaceRelay cardforintegrationtoindustrialenvironmentand buildingmanagementsystems,remoteshutdown forIBMAS/400systems Environmental Safetymarkings EMCmarkings Audiblenoise Ambient operating temperature Storage temperature Relativehumidity 120/208V:UL,CUL,VCCI 230V:CE,GS 120V:FCCClassB,EN55022ClassB(1.5kVAand below);FCCClassA,EN55022ClassA(2.0kVA andabove) 230V:CE(perIEC/EN62040-2:Emissions,Category C1;Immunity,CategoryC2) <50dB 0˚C(32˚F)to+40˚C(104˚F) -20˚C(-4˚F)to+40˚C(104˚F)withbatteriesand -25˚C(-13˚F)to+55˚C(131˚F)withoutbatteries 5–90%non-condensing Heat dissipation for all voltages: 208–240V and 120V 0.9 ±3%ofnominal 9130 model Normal mode, BTUs/hr On battery, BTUs/hr ±3%ofnominal 700 VA 350 554 >95%inhigh-efficiencymode;>86%inonlinemode ±3%Hzonline 1000 VA 500 674 1500 VA 750 1,011 2000 VA 838 1,348 3000 VA 1,257 1,755 3to1 Sinewave Twoconfigurable,individuallycontrolledreceptacles VRLA12V/9Ah(bothinternalandexternal) >3minuteswithinternalbatteries@100%load Hot-swappableinternalandexternalbatteries AllowsstartofUPSwithoututilityinput UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 www.eaton.com/powerquality CANADA Ontario: 416.798.0112 Toll free: 1.800.461.9166 LATIN AMERICA South Cone: 54.11.4124.4000 Brazil: 55.11.3616.8500 Andean & Caribbean: 1.949.452.9610 Mexico & Central America: 52.55.9000.5252 1 Due to continuing product improvement programs, specifications are subject to change without notice. The 9130 is part of the UPSgrade program UPSgrade™ www.eaton.com/UPSgrade EUROPE/MIDDLE EAST/AFRICA Denmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.0.7841.604.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Portugal: 55.11.3616.8500 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700 ASIA PACIFIC Australia: 61.2.9693.9366 New Zealand: 64.0.3.343.3314 China: 86.21.6361.5599 HK/Korea/Taiwan: 852.2745.6682 India: 91.11.4223.2300 Singapore/SEA: 65.6825.1668 Eaton, Powerware, ABM, Intelligent Power and UPSgrade are trade names, trademarks and/or service marks of Eaton Corporation or its subsidiaries and affiliates. All other trademarks are property of their respective owners. ©2011 Eaton Corporation All Rights Reserved Printed in USA 9130TFXA / TN June 2011 Product Brochure Eaton 9130 Rackmount UPS Product snapshot Product rating: 700–3000 VA Voltage 120 Vac, 208–240V Frequency: 50/60 Hz (auto-sensing) Configuration: Rackmount Advanced power protection for: • ITandnetworkingenvironments • Rackservers,networkinggear • Telecommunications,VoIP,securitysystems • Medicalsystems • Diagnosticsandmedicalscreening • Patientrecordarchives • Manufacturingsystems • Chipfabrication • Pharmaceuticalproduction • Chemicalprocessing Features • Protectsagainstdowntime,datalossandprocessinterruption byprovidingcontinuous,cleanpower • GraphicaluserinterfaceprovidesallcriticalUPSinformationon asinglescreenandenablessettingscontrolatthepushofa button • Providesupto3000VAinonly2Uofrackspace • Offerspremiumperformancewitha0.9powerfactorand>95 percentefficiencyinhighefficiencymode • IncreasesbatteryservicelifeandsystemuptimewithABM® batterychargingtechnology • Enablesprolongedruntimeofessentialequipmentduring poweroutagesbyallowingfororderly,remoteshutdownof non-criticalsystemsorprocesses • EnsuresdataandsystemintegritywithIntelligentPower® Managersupervisorysoftware,whichprovideseasy,versatile, remotemonitoringandmanagementofmultipledevices • Providesatwo-yearlimitedwarranty,anextendedwarranty, on-siteFlexandon-sitePowerTrustservicecontracts,anda $250,000loadprotectionguarantee(U.S.andCanada) Maximum availability • ABMtechnologyincreasesbatterylifeandsystemuptime • Loadsegmentsallowforselectiveloadsheddingduring outages • Optional2U,hot-swappableextendedbatterymodules(EBMs) extendbackupruntimeforhours • Internalhot-swappablebatteriescanbereplacedwithout poweringdowntheUPS • UPSstartuponbatterypower • HotSwapMaintenanceBypass(MBP)andPowerPass DistributionModules(PPDMs)optionsenabletheentireUPS tobeservicedorreplacedwithoutpoweringdowncritical systems Low total cost of ownership • Morerealoutputpowerfordollarspentwith0.9powerfactor • Cutsenergyusageandcostswith>95%efficiencyratingin highefficiencymode • 3000VAinonly2Uofspacesavesexpensivedatacenterreal estate UPS status and operation Hot-swappable internal batteries in only 2U • BrightfrontpanelLCDforeasymonitoringand management • LEDstoshowsystemstatus • OptionalFlexPDUaddsmoreplug-and-playflexibility, streamliningpowerdistribution • Multipleoptionsforindustry-standardcommunications • IntelligentPowerManagersupervisorysoftwareincludedfree ofcharge • DirectmonitoringviaexistingmanagementsystemsandLANs Communications • AstandardcommunicationslotacceptsinterfacesforWeb, SNMP,Modbusorserialconnectivity • ConnectdirectlytotheEthernetnetworkandtheInternetto monitorandmanagetheUPSwithastandardWebbrowser • Monitorpowerconditionsinrealtimethroughexistingfacilities orbuildingmanagementsystem • Monitorandgracefullyshutdownmultipleserversrunning variousoperatingsystems • ReceivealarmnotificationsfromtheUPS,environmental monitoringdevicesorsecuritysystems Add up to four EBMs for hours of runtime Intelligent Power Software Suite ByintegratingthesuitewiththeEaton9130,youcan: • SeamlesslyintegratewithVMware’svCenterServer™ virtualizationmanagementsolution,aswellas virtualizationplatformssuchasCitrix®XenServer, MicrosoftSCVMM™,RedHat®andotherXen®open sourceplatforms • Initiatelivemigrationofvirtualmachines(VM)to automaticallyandtransparentlymigrateVMsduring powerdisruptionstounaffecteddeviceswithsystems suchasVMwarevMotion™andMicrosoftLive Migration • IntegratewithVMwarevCenterSiteRecovery Manager Optional FlexPDU and HotSwap MBP for greater flexibility and uptime Four-post rail kit included (two-post rail kit optional) Tolearnmore,pleasevisit:Eaton.com/intelligentpower UPS rear panel (PW9130L1500R-XL2U) RemoteEmergency PowerOff(REPO) Communicationbay USBport Network-MScard (includedwith PW91304500R-XLLUN) Twoindividuallycontrolledloadsegments 2 EATON CORPORATION Eaton 9130 Rackmount UPS Standardrelay outputcontact RS-232port Linecordwith 5-15P 9130 models Rating (VA/Watts) Input connection1 Output receptacles Dimensions H x W x D, in Weight, lb 700/630 1000/900 1500/1350 5-15P 5-15P 5-15P (6)5-15R (6)5-15R (6)5-15R 3.4x17.2x17.7 3.4x17.2x17.7 3.4x17.2x17.7 35.3 35.3 43.0 2000/1800 2500/2250 3000/2700 1500/1350 2000/1800 3000/2700 5-20P L5-30P L5-30P 5-15P 5-20P L5-30P (6)5-20R,(1)L5-20R (6)5-20R,(1)L5-30R (6)5-20R,(1)L5-30R (6)5-15R (6)5-20R,(1)L5-20R (6)5-20R,(1)L5-30R 3.4x17.2x23.6 3.4x17.2x23.6 3.4x17.2x23.6 3.4(2U)x17.3x16.9 3.4(2U)x17.3x22.6 3.4(2U)x17.3x22.6 63.9 65.0 65.0 43.0 63.9 65.0 3000/2700 L6-20P4 (1)L6-30R,(1)L6-20R,(2)6-20R 3.4x17.2x23.6 65.0 PW9130G3000R-XL2UEU 103006483-6591 3000/2700 L6-20P (8)C13,(1)C19 3.4x17.2x23.6 International models: 230V, 50/60 Hz PW9130i1000R-XL2U 103006455-6591 1000/900 C14 (6)C13 3.4x17.2x17.7 PW9130i1500R-XL2U 103006456-6591 1500/1350 C14 (6)C13 3.4x17.2x17.7 PW9130i2000R-XL2U 103006457-6591 2000/1800 C14 (8)C13,(1)C19 3.4x17.2x23.6 PW9130i3000R-XL2U 103006463-6591 3000/2700 C20 (8)C13,(1)C19 3.4x17.2x23.6 Extended battery modules PW9130N1000R-EBM2U5 103006458-6591 NA NA NA 3.4x17.2x17.7 PW9130N1500R-EBM2U6 103006459-6591 NA NA NA 3.4x17.2x17.7 PW9130N3000R-EBM2U7 103006460-6591 NA NA NA 3.4x17.2x23.6 TAA Compliant SKUS Eaton now offers TAA compliant models for the 9130. Please visit Eaton.com/taaups for model specific information. 65.0 Catalog number Style number North American models: 120V, 50/60 Hz PW9130L700R-XL2U 103006447-6591 PW9130L1000R-XL2U 103006448-6591 PW9130L1500R-XL2U 103006449-6591 PW9130L2000R-XL2U 103006450-6591 PW9130L2500R-XL2U 103006451-6591 PW9130L3000R-XL2U 103006452-6591 PW9130L1500R-XL2UN PW9130L2000R-XL2UN PW9130L3000R-XL2UN Global models: 208V, 50/60 Hz PW9130G3000R-XL2U 103006454-6591 4 Catalog number 35.3 43.0 63.9 65.0 48.7 62.0 90.6 Description Input connection Output receptacles Dimensions H x W x D, in Weight, lb PowerPass Distribution Modules 103002730-6501 PPDM1-HV-US-P23kVA 103002732-6591 PPDM1-HV-US-HW3kVA(ROHS) 103002735-6591 PPDM2-LV-US-HW3kVA(ROHS) 103002739-6591 PPDM1-HV-US-P13kVA(ROHS) 103002742-6501 PPDM2-LV-US-P13kVA IEC320-C208 Hardwire Hardwire IEC320-C208 L5-30P8 (1)L5-30R&(6)5-20R Hardwire Hardwire (1)L14-30R&(6)5-20R (1)L5-30R&(6)5-20R 3.5(2U)x17.0x23.9 3.5(2U)x17.0x23.9 3.5(2U)x17.0x23.9 3.5(2U)x17.0x23.9 3.5(2U)x17.0x23.9 20.0 20.0 20.0 20.0 20.0 1.Inputcordlengthis6ft.2.Rackmodelsoccupy2Uofrackspaceandfitinto19-inchracks.3.C14,w/detachableL6-20P.4.C20,w/detachableL6-20P.5.ThisEBM workswith700/1000VAmodels,whereavailable.6.ThisEBMworkswith1500VAmodel.7.ThisEBMworkswith2000/2500/3000VAmodels,whereavailable.8. ConnectioncablestotheUPSareincludedwiththePPDM;usetheinputcordfromtheUPSasinputtothePPDM,exceptforhardwireunits.Additional notes:When highvoltage9130isusedat208V,deratepowerby10%and20%at200V.Whenlowvoltage9130isusedat110V,deratepowerby10%and20%at100V. Battery runtimes (in minutes) Load Internal (VA/Watts) batteries PW9130L700R-XL2U 700/490 14 525/368 20 350/245 32 175/123 64 PW9130L1000R-XL2U 1000/700 10 750/525 13 500/350 24 250/175 48 PW9130L1500R-XL2U 1500/1050 7 1125/788 11 750/525 18 375/263 38 PW9130i1500R-XL2U 1500/1050 7 1125/788 11 750/525 18 375/263 38 w/1 EBM w/2 EBMs w/3 EBMs w/4 EBMs 55 77 124 200 102 140 189 395 148 179 282 552 175 239 414 739 40 58 85 190 73 101 172 310 108 152 249 451 149 219 304 569 34 44 79 167 63 84 148 278 88 129 207 475 135 210 267 540 32 47 81 171 61 83 143 298 98 126 208 416 128 195 262 564 Battery runtime Youcangetuptofivehoursofbatteryruntimeusingthe internalbatteriesandextendedbatterymodules.Foradetailed, interactivebatteryruntimechart,pleasevisit:Eaton.com/9130. Load Internal (VA/Watts) batteries PW9130L2000R-XL2U 2000/1400 9 1500/1050 14 1000/700 26 500/350 52 w/1 EBM w/2 EBMs w/3 EBMs w/4 EBMs 45 66 101 197 86 115 185 353 124 165 251 481 163 225 343 629 PW9130L2500R-XL2U 2500/2250 7 31 59 87 1875/1688 10 43 81 121 1250/1125 17 65 120 163 625/563 40 145 228 363 PW9130L3000R-XL2U 3000/2100 5 25 48 72 2250/1575 8 37 72 102 1500/1050 13 60 100 165 750/525 34 138 228 326 PW9130G3000R-XL2U / PW9130G3000R-XL2UEU / PW9130i3000R-XL2U 3000/2100 6 25 45 68 2250/1575 8 34 70 96 1500/1050 14 62 92 156 750/525 34 130 212 355 119 154 203 491 100 137 223 438 96 130 211 442 Notes: Backuptimesareapproximateandmayvarywithequipment, configuration,batteryage,temperature,etc.Runtimesareshownata0.7 powerfactor. EATON CORPORATION Eaton 9130 Rackmount UPS 3 Technical specifications 1 General User interface LEDs Topology Diagnostics UPS bypass Dimensions Rail kit EBMs Remote Emergency Power-off (REPO) Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish Four status-indicating LEDs True online, double-conversion Full system self-test Automatic bypass See models table on previous page 4-post rail kit included with all rackmount units Ship with a 4-post rail kit Emergency shutdown control Electrical input Nominal voltage Voltage range 120V, 208V, 220–240V 120V: 90–138 Vac 208/230V: 160–276 Vac Power draw 700: 5.8A @120V, 3.4A @208V, 3.0A @230V of UPS 1000: 8.3A @120V, 4.8A @208V, 4.3A @230V 1500: 12.5A @120V, 7.2A @208V, 6.5A @230V 2000: 16.6A @120V, 9.6A @208V, 8.7A @230V 2500: 20.8A @208V, 10.9A @230V 3000: 14.4A @208V, 13.0A @230V Dedicated circuit 120V: breaker rating 700–1500 VA: 15A 2000 VA: 20A 2500–3000 VA: 30A 208/230V: 700–2000 VA: 10A 3000 VA: 16A Frequency 50/60 Hz Frequency range 45–65 Hz Electrical output Power factor On utility voltage regulation On battery voltage regulation Efficiency Frequency regulation Load crest factor Voltage waveform Load segments Battery Battery type Battery runtime Battery replacement Start-on-battery 0.9 ±3% of nominal Communications Serial port RS-232 standard, for interface to power management software USB port HID standard, for communicating with Windows 98, XP, ME and Vista computers Relay output Common alarm standard Communications Optional communication slots (BD Slot, Mini-Slot) slot Optional SNMP/Web card for direct control and monitoring communication in SNMP-based networks, monitoring of UPS status cards and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems Environmental Safety markings EMC markings 120/208V: UL, CUL, VCCI 230V: CE, GS 120V: FCC Class B, EN55022 Class B (1.5 kVA and below); FCC Class A, EN55022 Class A (2.0 kVA and above) 230V: CE (per IEC/EN62040-2: Emissions, Category C1; Immunity, Category C2) <50 dB 0˚C (32˚F) to +40˚C (104˚F) Audible noise Ambient operating temperature Storage -20˚C (-4˚F) to +40˚C (104˚F) with batteries and temperature -25˚C (-13˚F) to +55˚C (131 ˚F) without batteries Relative humidity 5–90% non-condensing Heat dissipation for all voltages: 208–240V and 120V Normal Mode 700 VA: 350 BTUs/hr 1000 VA: 500 BTUs/hr 1500 VA: 750 BTUs/hr 2000 VA: 838 BTUs/hr 2500 VA: 1,047 BTUs/hr 3000 VA: 1,257 BTUs/hr Battery 700 VA: 554 BTUs/hr Mode 1000 VA: 674 BTUs/hr 1500 VA: 1,011 BTUs/hr 2000 VA: 1,348 BTUs/hr 2500 VA: 1,463 BTUs/hr 3000 VA: 1,755 BTUs/hr 1 Duetocontinuingproductimprovementprograms,specificationsaresubjecttochange withoutnotice. ±3% of nominal >95% in high-efficiency mode; >86% in online mode ±3% Hz online 3 to 1 Sine wave The9130ispartoftheUPSgradeprogram Eaton.com/UPSgrade UPSgrade™ Two configurable, individually controlled receptacles What’s in the box • Towerpedestals • Four-postrailkit • • VRLA 12V/9 Ah (both internal and external) >3 minutes with internal batteries @100% load Hot-swappable internal and external batteries Allows start of UPS without utility input UsermanualCD IntelligentPowerSoftware SuiteCD • Quickstartguide • USBcable • RS-232serialcable • PhillipsHeadscrewdriver • 2 IECtoIECjumpercables (208V/230Vmodels) Comprehensive Eaton services available for 9130 Rack products • Warranty+extendedwarranties—3or5yearstotal • On-siteserviceplansforstartupsandpreventiveandcorrectivemaintenance VisitEaton.com/9130RMfordetails. For more information about the 9130, visit Eaton.com/9130RM . Eaton Corporation ElectricalSector 1111SuperiorAvenue Cleveland,OH44114USA Eaton.com ©2012EatonCorporation AllRightsReserved PrintedinUSA 9130RFXA October2012 Eatonisaregisteredtrademark ofEatonCorporation. Allothertrademarksareproperty oftheirrespectiveowners. Product Brochure 5–11 kVA Eaton 9PX UPS Reliable, versatile and efficient backup power for IT equipment, including Cisco switches and servers Eaton 9PX features and benefits Reliability: With extended battery runtime options, hot-swappable batteries, internal bypass and optional maintenance bypass, the 9PX maximizes the availability of your IT systems. More power: The 9PX allows you to connect more devices by providing up to 28 percent more wattage compared to traditional UPSs. Efficiency: The double-conversion online 9PX is the most efficient UPS in its class with up to 93 percent efficiency rating in normal mode. Split-phase models offer both 120V and 208V output without a transformer; saving vertical rack (U) space, weight and cost. Increased battery life: Eaton® offers ABM® technology that increases battery service life by 50 percent. ABM uses an advanced, three-stage charging technique and closely monitors battery health to provide advanced notice when batteries need replacement. Intuitive LCD interface: Eaton’s next-generation intuitive LCD interface offers a graphical display that provides all critical UPS information in a single view. The userfriendly menu allows you to view information and control settings with the push of a button. Intelligent Power Software Suite By integrating the bundled Intelligent Power® Software Suite (IPSS), you can monitor and manage your network power devices. IPSS enables you to: • Seamlessly integrate with VMware’s vCenter™ Server™ virtualization management solution, as well as virtualization platforms such as Citrix® XenServer, Microsoft SCVMM™, Red Hat® and other Xen® open source platforms • Initiate live migration of virtual machines (VMs) to automatically and transparently migrate them during power disruptions to unaffected devices with systems such as VMware vMotion™ and Microsoft Live Migration • Gracefully shutdown computers, VMs and host servers during an extended power outage To learn more, please visit: Eaton.com/intelligentpower Services and support Eaton provides 24x7 product support. From battery replacement to full UPS service plans, Eaton has one of the top service models in the industry. The Eaton 9PX is an ENERGY STAR® qualified UPS. ENERGY STAR is intended to help consumers save money and protect the environment through energy efficient products and practices. Versatile configurations Graphical LCD interface The 9PX has the versatility to meet the demands of a wide array of IT applications. With an LCD interface that tilts 45 degrees for optimal viewing, rotates to match rack and tower installations, and provides clear information on UPS status and measurements, the 9PX makes local management easy. Each 9PX includes a 4-post rail kit. The 9PX displays key data such as its up to 93 percent efficiency rating, alarm history, runtime remaining, load percentage and more in a graphical format. Split-phase models incorporate flexible receptacle configurations that natively offer both 208 and 120 volt. Rear panel of 9PX 6K split-phase shown above. The 9PX provides line and match EBMs for extended runtime. Virtualization-ready UPS Every 9PX comes with the Network Card-MS and IPSS, allowing seamless integration into the following industry-leading virtualization platforms: Intelligent Power Manager plugs into VMware’s vCenter dashboard. The bundled Network Card-MS allows the 9PX to connect to an Ethernet network and the Internet, supporting real-time monitoring and control of UPSs across the network via a standard Web browser, SNMP-compliant network management system or power management software. 2 EATON Eaton 9PX UPS Eaton.com/9PX Rear panel overview Model 9PX6KTF5 (6kVA, 120/208V output) 5 1 9 3 9 12 13 6 11 2 7 4 15 14 UPS 10 8 17 1 Remote Power Off (RPO) 2 EBM detection port 3 Network Card-MS (bundled with UPS) 4 EBM connector 5 Remote On/Off (ROO) 6 Output relay contact – DB-9 dry contact (common alarm as standard). 7 USB port (cable included) 8 RS-232 serial communication port (cable included) 9 Output circuit breaker protection 10 (2) L6-20R Transformer 16 18 11 (2) L6-30R 12 Ground bonding screw 13 6-foot line cord with L6-30P Model 9PX10KSP (10kVA, 120/208V output) 14 Output terminal block for hardwired applications 1 2 15 30A main circuit breaker 5 7 6 16 UPS 9 (4) 20A circuit breakers 17 (18) 5-20R outlets 8 (accommodates 5-20P and 5-15P 3 18 L6-30P input cord 19 (2) L14-30R 20 EBM 20 (1) L6-30R 19 4 14 Transformer To interact with the 9PX and see additional configurations up close, please visit Eaton.com/9PX. EATON Eaton 9PX UPS Eaton.com/9PX 3 9PX model selection guide The 9PX UPS is pre-configured into bundles for easy Configuration and deployment. For complete specifications, including interactive battery runtime graphs, please visit Eaton.com/9PX. 9PX SP 6-10 kVA rack/tower: 120/208 output, 50/60 Hz Catalog number Rating (VA/Watts) Input 9PX6KSP 5500/4900**** L14-30P*** 9PX8KSP 8000/7200 Hardwired 9PX10KSP 10000/9000 Hardwired Output (1) L14-30R, (1) L6-30R, (6) 5-20R, HW (2) L14-30R, (1) L6-30R, HW (2) L14-30R, (1) L6-30R, HW **UPS and EBM ship with a 4-post rail kit, 9RK. ***Terminal block with L14-30P cord. **** 6K models derated at 100/200, 120/208, 110/220V (see technical specs). Dimensions (HxWxD, in.) 6.8 (4U) x 17.3 x 25.6 10.3 (6U) x 17.3 x 27.6 10.3 (6U) x 17.3 x 27.6 Weight (lb.) 157.3 225 225 Extended battery modules: 6-10kVA Split-phase Catalog number Description 9PXEBM240SP 6K SP EBM (add up to 4 EBMs), Use with 9PX6KSP UPS EBMCBL240SP 9PX EBM Cable Extension 6kVA Split-Phase , 6 feet (1.8 meters) 9PXEBM360SP 8/10K EBM (add up to 4 EBMs) Use with 9PX8KSP, 9PX10KSP UPS EBMCBL360SP 9PX EBM Cable Extension 8/10kVA Split-Phase , 6 feet (1.8 meters) 9PX 5-11 kVA 208V output, 50/60 Hz bundles Catalog number Rating (VA/watts) Input Output 9PX5K 5000/4500 L6-30P** (2) L6-30R, (2) L6-20R, Hardwired 9PX6K 6000/5400 L6-30P** (2) L6-30R, (2) L6-20R, Hardwired 9PX6KG 6000/5400 Hardwired (2) C19, (8) C13, Hardwired 9PX8KHW 8000/7200 Hardwired Hardwired 9PX8K 8000/7200 Hardwired Hardwired, (3) L6-30R 9PX11KHW 11000/10000 Hardwired Hardwired 9PX11K 11000/10000 Hardwired Hardwired, (3) L6-30R 9PX 5-11 kVA 120/208V output, 50/60 Hz bundles Catalog number Rating (VA/watts) Input 9PX5KTF5 5000/4500 L6-30P** 9PX5KP1 5000/4500 L6-30P 9PX5KP2 5000/4500 Hardwired 9PX6KTF5 6000/5400 L6-30P** 9PX6KP1 6000/5400 L6-30P 9PX6KP2 6000/5400 Hardwired 9PX8KTF5 8000/7200 Hardwired 9PX11KTF5 11000/10000 Hardwired 9PX11KTF11 11000/10000 Hardwired Output (1) L6-30R, (2) L6-20R, (18) 5-20R, Hardwired (1) L14-30R, (1) L6-30R, (6) 5-20R Hardwired (1) L6-30R, (2) L6-20R, (18) 5-20R, Hardwired (1) L14-30R, (1) L6-30R, (6) 5-20R Hardwired Hardwired, (2) L6-30R, (18) 5-20R Hardwired, (2) L6-30R, (18) 5-20R Hardwired, (2) L14-30R, (8) 5-20R Dimensions (HxWxD, in.) 5.1 (3U) x 17.3 x 26.6 Weight (lb.) 132 5.1 (3U) x 17.3 x 25.4 163 Dimensions (HxWxD, in.)* 5.1 (3U) x 17.3 x 28.4 5.1 (3U) x 17.3 x 28.4 5.1 (3U) x 17.3 x 27.0 10.2 (6U) x 17.3 x 27.6 10.2 (6U) x 17.3 x 30.0 10.2 (6U) x 17.3 x 27.6 10.2 (6U) x 17.3 x 30.0 Weight (lb.) 106 106 106 190 205 190 205 Dimensions (HxWxD, in.)* 10.2 (6U) x 17.3 x 28.4 10.2 (6U) x 17.3 x 28.4 10.2 (6U) x 17.3 x 28.4 10.2 (6U) x 17.3 x 28.4 10.2 (6U) x 17.3 x 28.4 10.2 (6U) x 17.3 x 28.4 15.3 (9U) x 17.3 x 30.0 15.3 (9U) x 17.3 x 30.0 15.3 (9U) x 17.3 x 27.6 Weight (lb.) 201 203 201 201 203 201 300 300 377 *Each module of every 9PX bundle ships with a 4-post rail kit. **Terminal block with L6-30P cord. Extended battery modules (EBM) and accessories: 5 and 6kVA Catalog number Description 9PXEBM180RT EBM; includes 4-post rail kit, quick start guide, joining brackets for tower configuration and 1-foot connector cable; add up to 4 EBMs EBMCBL180 9PX EBM Cable Extension 5 and 6 kVA UPS models, 6 feet (1.8 meters) CBLADAPT180 Adapter cable from Eaton 9135/MX UPS EBM to 5 and 6 kVA 9PX UPS models Extended battery modules (EBM) and accessories: 8 and 11kVA 9PXEBM240RT EBM; includes 4-post rail kit, quick start guide, joining brackets for tower configuration and 1-foot connector cable. Add up to 5 EBMs with UPS; add up to 12 EBMs with SC240RT SC240RT 240V supercharger module to add up to 12 EBMs to 8 and 11 kVA 9PX UPS models. Includes 4-post rail kit. EBMCBL240 Cable Extension 8 and 11 kVA UPS models, 6 feet (1.8 meters) CBLADAPT240 Adapter cable from 9135, MX and EX RT UPS EBMs to 8 and 11 kVA 9PX UPS models Power distribution & bypass Catalog number Description MBP6K208 208V maintenance bypass module MBP11K208 208V maintenance bypass module PW105BA2U420 Basic ePDU ePBZ79 Basic ePDU PW105BA0U421 PW105BA2U422 Basic ePDU Basic ePDU Compatible 9PX models Input Output All non split-phase 5 and 6 kVA models L6-30P (2) L6-30R All non split-phase 8 and 11 kVA models Hardwired Hardwired, (3) L6-30R 9PX5K, 9PX6K, 9PX5KTF5, 9PX6KTF5, 9PX6KP1, 9PX8KTF5, 9PX8K, L6-30P (4) L6-20R 9PX11KTF5, 9PX11K 9PX5K, 9PX6K, 9PX5KTF5, 9PX6KTF5, 9PX6KP1, 9PX8KTF5, 9PX8K, L6-30P (16) C13, (4) C19 9PX11KTF5, 9PX11K 9PX5KP1, 9PX6KP1, 9PX11KTF11 L14-30P (24) 5-20R 9PX5KP1, 9PX6KP1, 9PX11KTF11 L14-30P (4) L6-20R Dimensions (HxWxD, in.) Weight (lb.) 5.1 (3U) x 17.3 x 25.4 150 5.1 (3U) x 17.3 x 25.4 143 5.1 (3U) x 17.3 x 26.8 34 Dimensions (HxWxD, in.) 3U rackmount Rear-mount Weight (lb.) 9 15 3.5 (2U) x 19.0 x 6.0 10 1.7 (1U) x 17.0 x 5.1 6 66.0 (0U) x 1.89 x 2.0 3.5 (2U) x 19.0 x 6.0 10 10 Other hardware accessories Catalog number Description RK2PC 2-post rail kit for 5 and 6 kVA 9PX models Battery integration system and caster kit BINTSYS Dimensions (HxWxD, in.) Weight (lb.) Fits 2-post racks 5 7.9 x 20.5 x 31.5 30 To interact with the 9PX UPS, please visit: Eaton.com/9PX Eaton Electrical Sector 1111 Superior Avenue Cleveland, OH 44114 USA Eaton.com © 2013 Eaton All Rights Reserved Printed in USA 9PX01FXA December 2013 Eaton is a registered trademark of Eaton. All other trademarks are property of their respective owners. ENERGY STAR and the ENERGY STAR mark are registered U.S. marks. ENERGY STAR is a registered mark owned by the U.S. government. ProductBrochure Eaton 9170+ UPS Features • N+Xredundancyforbothpowerandlogiceliminatessystemlevelsinglepoint-of-failure • EasilyscalabletoadapttochangingITenvironmentsbysimply addingpowerand/orbatterymodules • Truedouble-conversiondesign • ABM®technologysignificantlyincreasesbatteryservicelife • Universalcomponentsfitinanyorderwithoutaffecting UPSoperation • Providesprotectionagainstallninepowerproblems • Completeofferingofpowermanagementsoftwareincludedto ensuredataintegrity • Providesinvestmentprotectionwithatwo-yearlimitedwarranty anda$250,000loadprotectionguarantee(U.S.andCanada) Product Snapshot Power Rating: 3–18 kVA Input Voltage: 200–240 Vac Output Voltage: 200–240 Vac Frequency: 50/60 Hz (auto-sensing) Configuration: Tower or rackmount TheEaton®9170+UPSisuniquelydesignedtomeettheeverchangingneedsofcustomerswithapplicationssuchasdata centers,networksandcallcenters.Builtforglobaldeployment,the 9170+isascalable,modular,flexiblesolutionthatcombinesthe highestlevelofreliabilitywiththelowestcostofownership inthe3–18kVArange. The9170+enablescustomerstobuildapowersolutionspecificto theirneeds,withanexpandablelevelofredundancyandincreases runtimesthroughplug-and-play3kVAUPSandbatterymodules. The9170+canbeconfiguredtofitthree-,six-,nine-ortwelve-slot enclosures,andisavailablefortowerandrackmountapplications. The9170+alsofeaturesaPowerSavermode,auser-selectable featurethatincreasesunitefficiencyfrom88%innormaloperating modeto97%.Withitslowinitialinvestment,double-conversion technology,ABMbatterymanagementsystemandhigh-efficiency PowerSavermode,youneverhavetocompromisereliabilityfor efficiency. Uniquetothe9170+isitsglobaldeploymentcapability.Byusing ahigh-frequencydesign,housingbothlogicandpowerinthe powermodule,andofferingasingle-cabinetdesign,distributors andpurchasingdepartmentsaroundtheworldhavefewersystem componentstocontendwith,regardlessofwherethesystemis deployed. Technical spotlight: Network level N+X redundancy Asbusinessmovesfroma“bricksandmortar”modelto“clicks andmortar,”theneedforsystemavailabilityatalllevelsof enterpriseisrisingexponentially.Fromserverstoroutersto telecommunicationinstallations,theinterdependenceofthe technologicalcomponentsofthewiredworldcanmakesystems vulnerabletodowntime.Manyprecautionsandpreventive measuresaretakenwhendesigningthenetwork,includingpower protection. systemswithasingle-moduleUPS.The9170+overcomesthis potentialobstaclewithitsmodulardesign.Redundancycomes fromthe3kVApowermodulespluggedintothesystem.For example,ifyouhavea9kVAsolution,andarelookingforN+2 redundancy,youonlyneeda15kVAUPS(fivepowermodules) withthe9170+,insteadof18kVA.That’sbecausethefive UPSmodulesruninparallelwithinthesystem,givingyouN+2 redundancy,withouttheadditionalcostandspacerequirements. Inthisshiftingworld,however,it’sbecomingmoreevidentthat simplepowerprotectionisn’tenough.Anewlevelofreliability isneeded,onewithredundancy,andtherebysystemavailability. Todayuserscanoptforanevengreaterdegreeofredundancy, withN+1,N+2,N+3,etc.However,thislevelofredundancycan quicklybecomecostprohibitiveiftheuseriscreatingredundant The9170+eliminatesasystem-levelsinglepoint-of-failure. Becauseboththelogicandpowerarehousedinthemoduleand notintheenclosure,thereisaredundancyfortheentireUPS. Thisisacriticaldistinctionwhenlookingformultiplelevelsof redundancyintheUPS,asthereisinherentvulnerabilityinaUPS thatlimitsredundancyinanypartofthesystem. Sample configuration Withavarietycabinetsizesandauser-friendlydesignyoucan configurethescalableandredundant9170+with3kVApower modulesandbatterymodulestogrowwithyourrequirements. 5 power modules: 15 kVA or 12 kVA N+1 or 9 kVA N+2 20 battery modules 9-slot UPS enclosure 2 EATON CORPORATION Eaton 9170+ UPS 9-slot battery enclosure PRE-CONFIGURED SYSTEMS WITH HARDWIRE INPUT AND OUTPUT POWER RATING INPUT CONNECTION OUTPUT CONNECTIONS DIMENSIONS H x W x D (IN/CM) WEIGHT (LB/KG) (1)3-slotenclosure (1)powermodule (2)batterymodules (1)casterkit 3kVAexpandable to3kVAN+1 Hardwired Hardwired 19.5x17.0x25.5/ 49.5x43.0x65.0 155.0/69.9 (1)6-slotenclosure (1)powermodule (2)batterymodules (1)casterkit 3kVAexpandable to9kVAN+X Hardwired Hardwired 33.3x17.0x25.5/ 84.5x43.0x65.0 155.0/69.9 (1)6-slotenclosure (2)powermodules (4)batterymodules (1)casterkit 6kVAexpandable to9kVAN+X Hardwired Hardwired 33.3x17.0x25.5/ 84.5x43.0x65.0 232.0/104.8 (1)6-slotenclosure (3)powermodules (6)batterymodules (1)casterkit 9kVAexpandable to9kVAN+X Hardwired Hardwired 33.3x17.0x25.5/ 84.5x43.0x65.0 346.0/156.7 PW9S9K (1)9-slotenclosure (3)powermodules (6)batterymodules 9kVAexpandable to18kVAN+X Hardwired Hardwired 47.0x24.0x28.5/ 119.5x61.0x72.5 389.0/176.7 PW12S9K (1)12-slotenclosure (3)powermodules (6)batterymodules 9kVAexpandable to18kVAN+X Hardwired Hardwired 60.7x24.0x28.5/ 154.5x61.0x28.5 427.0/193.7 PW12S12K (1)12-slotenclosure (4)powermodules (8)batterymodules 12kVAexpandable to18kVAN+X Hardwired Hardwired 60.7x24.0x28.5/ 154.5x61.0x28.5 504.0/228.6 PW12S15K (1)12-slotenclosure (5)powermodules (10)batterymodules 15kVAexpandable to18kVAN+X Hardwired Hardwired 60.7x24.0x28.5/ 154.5x61.0x28.5 581.0/263.5 PW12S18K (1)12-slotenclosure (6)powermodules (12)batterymodules 18kVAexpandable to18kVAN+X Hardwired Hardwired 60.7x24.0x28.5/ 154.5x61.0x28.5 658.0/298.4 MODEL NUMBER INCLUDED ITEMS PW3S3K PW6S3K PW6S6K PW6S9K Pre-configured systems with hardwire input and receptacles output options (1)6-slotenclosure (1)powermodule (2)batterymodules (1)casterkit 3kVAexpandable to9kVAN+X Hardwired (2)L14-30R, (2)L6-30R, (12)5-20R 33.3x17.0x25.5/ 84.5x43.0x65.0 192.0/86.9 (1)6-slotenclosure (2)powermodules (4)batterymodules (1)casterkit 6kVAexpandable to9kVAN+X Hardwired (2)L14-30R, (2)L6-30R, (12)5-20R 33.3x17.0x25.5/ 84.5x43.0x65.0 269.0/121.8 (1)6-slotenclosure (3)powermodules (6)batterymodules (1)casterkit 9kVAexpandable to9kVAN+X Hardwired (2)L14-30R, (2)L6-30R, (12)5-20R 33.3x17.0x25.5/ 84.5x43.0x65.0 346.0/160.7 PW9S9K-PD (1)9-slotenclosure (3)powermodules (6)batterymodules 9kVAexpandable to18kVAN+X Hardwired (2)L14-30R, (2)L6-30R, (12)5-20R 47.0x24.0x28.5/ 119.5x61.0x72.5 389.0/176.7 PW12S9K-PD (1)12-slotenclosure (3)powermodules (6)batterymodules 9kVAexpandable to18kVAN+X Hardwired (3)L14-30R, (3)L6-30R, (12)5-20R 60.7x24.0x28.5/ 154.5x61.0x28.5 427.0/193.7 PW12S12K-PD (1)12-slotenclosure (4)powermodules (8)batterymodules 12kVAexpandable to18kVAN+X Hardwired (3)L14-30R, (3)L6-30R, (12)5-20R 60.7x24.0x28.5/ 154.5x61.0x28.5 504.0/228.6 PW12S15K-PD (1)12-slotenclosure (5)powermodules (10)batterymodules 15kVAexpandable to18kVAN+X Hardwired (3)L14-30R, (3)L6-30R, (12)5-20R 60.7x24.0x28.5/ 154.5x61.0x28.5 581.0/263.5 PW12S18K-PD (1)12-slotenclosure (6)powermodules (12)batterymodules 18kVAexpandable to18kVAN+X Hardwired (3)L14-30R, (3)L6-30R, (12)5-20R 60.7x24.0x28.5/ 154.5x61.0x28.5 658.0/298.4 PW6S3K-PD PW6S6K-PD PW6S9K-PD Pre-configured systems with line cord input and receptacles output options PW3S3K-LPD (1)3-slotenclosure (1)powermodule (2)batterymodules 3kVAexpandable to3kVAN+1 L14-30P (1)L14-30R, (1)L6-30R, (4)5-20R 19.5x17.0x25.5/ 49.5x43.0x65.0 155.0/69.9 PW6S3K-LPD (1)6-slotenclosure (1)powermodule (2)batterymodules 3kVAexpandable to6kVAN+1 14-50P (2)L14-30R, (2)L6-30R, (12)5-20R 33.3x17.0x25.5/ 84.5x43.0x65.0 192.0/86.9 PW6S6K-LPD (1)6-slotenclosure (2)powermodules (4)batterymodules 6kVAexpandable to6kVAN+1 14-50P (2)L14-30R, (2)L6-30R, (12)5-20R 33.3x17.0x25.5/ 84.5x43.0x65.0 269.0/121.8 Notes: 50/60 Hz automatic frequency selection. Input/Output voltages 208–240V or 100/200,120/208, 127/220, 110/220 and 120/240V. Split phase power module offers both high and low output voltage. Universal power module offers only high output voltage. All 3- and 6-slot enclosure dimensions include caster kit. EATON CORPORATION Eaton 9170+ UPS 3 UPS CABINET ENCLOSURES WITH HARDWIRE INPUT AND OUTPUT CONNECTIONS POWER RATING INPUT CONNECTION OUTPUT CONNECTIONS DIMENSIONS H x W x D (IN/CM) WEIGHT (LB/KG) PW9170+ 3-slot 3kVA Hardwired Hardwired 17.8x17.0x25.5/ 45.0x43.0x65.0 66.0/30.0 PW9170+ 6-slot 3to9kVA Hardwired Hardwired 31.5x17.0x25.0/ 80.0x43.0x65.0 103.0/47.0 PW9170+ 9-slot 3to18kVA Hardwired Hardwired 47.0x24.0x28.5/ 119.5x61.0x72.5 158.0/72.0 Rackmount 3to18kVA Hardwired Hardwired 47.0x17.0x28.5/ 119.5x43.0x72.5 110.0/50.0 PW9170+ 12-slot 3to18kVA Hardwired Hardwired 60.8x24.0x28.5/ 196.0/89.0 154.0x61.0x72.5 Rackmount 3to18kVA Hardwired Hardwired 60.8x17.0x28.5/ 154.0x43.0x72.5 148.0/67.0 6-slot battery cabinet - DCinterconnect optionASY-0525 required - 31.5x17.0x25.0/ 80.0x43.0x65.0 93.0/42.2 9-slot battery cabinet - DCinterconnect optionASY-0525 required - 47.0x24.0x28.5/ 119.5x61.0x72.5 148.0/67.1 12-slot battery cabinet - DCinterconnect optionASY-0525 required - 60.8x24.0x28.5/ 154.0x61.0x72.5 186.0/84.4 Split-phase power module 3kVA/2.5kW - - 4.2x14.1x15.3/ 10.6x35.8x38.9 17.0/7.7 Universal-phase power module 3kVA/2.1kW - - 4.2x14.1x15.3/ 10.6x35.8x38.9 17.0/7.7 - - - 4.2x7.0x14.8/ 10.6x17.8x37.6 30.0/13.6 3kVA - - 4.2x14.1x15.3/ 10.6x35.8x38.9 17.0/7.7 MODEL NUMBER Battery cabinet enclosures Available modules Battery module 20-amp charger module Technical specifications 1 ELECTRICAL INPUT Voltage Voltagerange Inputpowerfactor Frequency GENERAL 208–240Vor200/100,208/120, 220/110,240/120Vac 176–276V .98 50/60Hz(±3Hz) ELECTRICAL OUTPUT Onutilityvoltage regulation Onbattery voltageregulation Efficiency mode Frequencyregulation Truedouble-conversiononline Fullsystemself-testonpowerup AutomaticonoverloadorUPSfailure SeePre-configuredsystemstable ENVIRONMENTAL AND SAFETY ±3%ofnominal ±3%ofnominal 88%normaloperation;97%powersaver (optionalprogrammable) ±3Hzonline;±0.1Hzonbattery COMMUNICATIONS LCD Language support Communication ports Communication slots SNMPcapability Contactclosures Emergencypoweroff (EPO)general Topology Diagnostics UPSbypass Dimensions& weights 4x20characterbacklitdisplay, programmable English,French,SpanishandGerman Safetymarkings EMCmarkings Surge suppression Audiblenoise Ambientoperating/ storagetemperature Relativehumidity REPOport UL,cUL FCCclassA IEEE/ANSIC62.41 <50dBA 0to40ºC(32to104ºF)/ -20to40ºC(60ºCwithoutbattery) -4to104ºF(140ºFwithoutbattery) 5%to95%,non-condensing MeetsNECcode645-11intent andULrequirements BATTERY RS-232(DB-9) Twoslots(standard) Web/SNMPenabledcardoptions Relaycardoption InputforexternalEPO Internalbattery type Batteryruntime Batteryreplacement Rechargetime Sealed,lead-acid;maintenancefree SeeBatteryRuntimesonbackpage Hot-swappable <4hoursstandard 1. Due to continuing product improvement programs, specifications are subject to change without notice. EATON CORPORATION Eaton 9170+ UPS 4 LCD panel 9170+ 9-slot configuration 3 kVA power or charger module (one per slot) Communication cards Rackmount Battery module (two per slot) Maximum performance Maximum availability Maximum flexibility • Thelowestoverallcostof ownershipisadirectresult ofthelowinitialinvestment, higheroperatingefficiencies andprogrammablehigh efficiency • Double-conversiononline technologyisuniversally recognizedasprovidingthe highestavailabilityinan internet-centricglobal marketplace • Modulardesigndelivers scalable,flexiblesolutions toconstantlychanging equipmentrequirements • AUPSsolutionthatisas easytoinstallandoperateas aPC—universalcomponents fitinanyorderinany slotwithoutaffectingthe operationofthesystemor itsprotectionofthecritical load • Providesprotectionagainst allninecommonpower problems • Easilyexpandedbyinstalling additionalpower,chargeror batterymodulestosupport additionalcriticalapplications anddevices Maximum service plans • Internaloptions:linecord, receptacles,communications • Featuringuser-friendly LCDandtwointernal communicationslots,which acceptawidevarietyof connectivitydevicesand thenewConnectUPSWeb/ SNMPcard • Lightweight,highperformancepowerand batterymodulesweighunder 30poundsforeasyservice andhot-swapping Maximum reliability • N+Xpowerandlogic redundancyeliminatessingle point-of-failure,providing highestreliabilityand availability • EatonGoldPlanPlus: Enhanceandextendyour standardUPSwarrantywith addedassuranceofknowing yourUPSisinstalledand operatingproperlyfrom thestart • Comprehensivecoverage fortheentireUPS Rackmount configurations Addingyetanotherlevelof flexibilitytotheuniquedesign ofthe9170+istheabilityto configureitintoarackmount solution.Imagineallthe standardbenefitsofthe9170+ installedinastandard19-inch computerrackwithreturn brackets. • Externaloptions:rackmount kit,casters(standardon 9-and12-slotenclosures), extendedruntimebattery cabinets(housingupto8 hoursofadditionalruntime), wall-mountedmaintenance bypasscabinets • On-sitestartupbyauthorized Eatonproductrepresentative • ReplacementUPSormodule deliveredtoyourlocation • OriginalUPSormodule pickedupfromyourlocation • Pleasecallfordetails • Redundantmodularity virtuallyeliminatesdowntime andenhancesserviceability • ABMtechnologysignificantly increasesbatteryservicelife EATON CORPORATION Eaton 9170+ UPS 5 9170+ runtime charts IN MINUTES (FULL LOAD/HALF LOAD) SPLIT-PHASE MODULE ASY-0673 3kVA 6kVA 9kVA 12kVA 15kVA 18kVA 3kVA 6kVA 9kVA 12kVA 15kVA 18kVA Load (VA) number of strings (two battery modules per string) 1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String 9 String 10 String 11 String 12 String 6.5/16 27.5/67.5 11/27.5 6.5/16 40/98 16/40 9.5/23.5 6.5/16 53.5/132 21.5/53.5 13/31.5 9/21.5 6.5/16 67.5/167 27.5/68 16/40 11/27.5 8/20.5 6.5/16 83/204 33.5/83 20/49 13.5/33.5 10/25 8/20 98/242 40/98 23.5/58 16/40 12/30 9.5/23.5 115/283 46.5/115 27.5/67.5 19/46.5 14/35 11/27.5 132/324 53.5/132 31.5/78 21.5/53.5 16/40 12.5/30 149/365 60.5/149 35.5/88 24.5/60.5 18.5/45 14.5/35.5 167/408 67.5/167 40/98 27.5/68 20.5/50.5 16/40 13 String 14 String 15 String 16 String 17 String 18 String 19 String 20 String 21 String 22 String 23 String 24 String 185/456 75/185 44/109 30.5/75 23/56 18/44 283/692 115/285 68/167 46.5/115 35/86 27.5/68 302/750 123/302 73/179 50/123 37.5/92 29.5/73 323/790 132/324 78/191 53.5/132 40/98 31.5/78 345/850 140/345 83/204 57/140 42.5/105 33.5/83 365/900 149/365 88/210 60/149 45/111 35.5/88 387/955 157/388 93/229 64/157 48/118 38/93 408/1015 167/408 98/242 68/167 51/124 40/98 16/40 6.5/16 204/501 83/204 49/120 33.5/83 25/62 20/49 223/549 90/223 53.5/132 37/90 27.5/67.5 21.5/53.5 242/595 98/242 58/143 40/98 30/73.5 23.5/58 262/640 106/262 63/154 43/106 32.5/79.5 25.5/63 IN MINUTES (FULL LOAD/HALF LOAD) UNIVERSAL MODULE ASY-0674 Load (VA) number of strings (two battery modules per string) 1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String 9 String 10 String 11 String 12 String 3kVA 6kVA 9kVA 12kVA 15kVA 18kVA 8/24 43/95 16/40 8/24 58/140 24/59 13/35 8/24 80/175 32/83 18/46 13/33 8/24 95/215 40/103 24/59 16/40 11.5/31 8/24 119/240 49/114 29/63 19.5/43.5 14.5/31.5 11/31.5 135/290 58/140 35/86 24/59 18/46 13/36 155/335 69/156 40/103 29/70 20.5/51 15.5/41 65/365 83/175 46/115 33/80 24/58 18/45 200/395 90/190 54/125 36/90 28/66 20.5/51 215/450 103/205 58/140 41/100 31/73 24/58 13 String 14 String 15 String 16 String 17 String 18 String 19 String 20 String 21 String 22 String 23 String 24 String 3kVA 6kVA 9kVA 12kVA 15kVA 18kVA 225/500 113/335 63/150 47/110 34/83 27/65 335/690 156/333 100/210 70/156 51/127 41/100 350/720 165/350 107/225 75/165 56/130 44/105 365/780 175/365 115/240 80/175 58/140 45/115 375/850 183/385 121/255 85/185 61/149 48/122 395/890 190/395 125/270 90/195 66/158 54/131 425/920 198/420 135/280 95/205 71/165 57/137 450/950 205/440 143/290 100/215 73/170 58/140 24/59 8/24 245/540 123/255 73/165 52/121 38/94 31.5/72 270/600 135/273 80/178 56/130 41.5/103 34.5/77 290/620 143/290 86/190 58/140 44.5/113 36/83 315/650 148/315 93/200 65/147 46.5/117 38/94 For additional information about the 9170+, please visit Eaton.com/9170+ or call 800.356.5794. Eaton Corporation Electrical Sector 1111 Superior Avenue Cleveland, OH 44114 USA Eaton.com © 2012 Eaton Corporation All Rights Reserved Printed in USA 9170PLFXA November 2012 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners. Eaton BladeUPS Maintenance Bypass Module (MBM) Features • Three-BreakerMaintenanceBypass •Maintenancebypassbreaker,rectifierinputbreakerandUPS outputbreakerallratedfor225A@208V(150A@400V)for highavailabilityevenastheUPSisserviced • 6URackmountCabinet •60kWN+1maintenancebypassinjust6Uofrackspace; matchingfrontbezelblendsMBMintoexistingracksof Eaton®BladeUPS®extendedbatterymodules • BreakerInterlockBar •Ensurescorrectbreakersequencingduringtransitionto bypassandreturntoonline • ActivateUPSBypassModeSwitch •WiththepressofthissingleswitchtheBladeUPSrackis automaticallyplacedintobypassandtheentiresystemis readiedforthetransferofpower • Designedtogointotoporbottomoftheenclosure(rack) •TheMBMhasthreeremovableconduitlandingplateson thetopandbottomofthecabinettoensurecableentry canbeaccommodatedforraisedfloororoverheadwiring installations The Eaton BladeUPS Maintenance Bypass Module (MBM) is a fully featured maintenance bypass designed to transfer power from a fully populated 60 kW N+1 BladeUPS system into bypass, allowing maintenance and service to be performed on a de-energized BladeUPS cabinet without affecting power to the critical load. Factory installed 225A @208V (150A @400V) maintenance bypass breaker (MBB), UPS Input Breaker (UIB) and UPS output breaker (UOB). A breaker interlock bar ensures the proper sequencing of the MBB and UOB when bringing the BladeUPS cabinet off and online. The MBM’s Activate UPS Bypass Mode switch simplifies the process of going to bypass even further by providing a single point to transfer all BladeUPS units into bypass, and ready the system for the transfer of power. The MBM is designed to fit seamlessly into your data center environment while occupying minimal space. The 6U housing features front panels designed to mimic the look of BladeUPS EBM extended battery modules (EBMs) so that it will fit aesthetically into your BladeUPS rack. Behind the removable front panels are four LEDs that highlight the current power flow of the system and enhance the safety and security of on-site operators. The MBM also features a shunt trip on the bypass breaker for interfacing with remote emergency power-off (EPO) systems, and all breakers have auxillary contacts (NC and NO available) for breaker on/ off sensing for integration with building control or monitoring systems. Technical specifications ENVIRONMENTAL SPECIFICATIONS GENERAL CHARACTERISTICS Type Three-breaker, manual interlock Installation Rack mounted, 6U Input & Output Cabling Top and bottom entry Designed kVA/kW rating 60 kVA/60 kW Color Black bezels matching BladeUPS Construction NEMA 1, IP 23 INPUT/OUTPUT RATINGS 208V MODEL 103007415-5208 Input Voltage 120/208V: Three-phase Frequency 50/60 Hz Input Connection Hardwire 3P + N + PE Output Voltage 120/208V: Three-phase Ambient Temperature 0°C to +40°C +32°F to +104°F Storage Temperature -20°C to +70°C -4°F to +158°F Relative Humidity 5-95% non-condensing Altitude 2000 meters (6560ft.) at 40°C/104°F Audible Noise Less than 50 dBA at 1 meter CERTIFICATIONS Safety UL 1778 4th edition IEC 60950-1 edition 1 IEC 62040-1-1 edition 1 EMC IEC 62040-2 edition 2 Quality ISO 9001:2000 ISO 14001, 2006 Markings UL, cUl, CE ELECTRICAL RATINGS 208V MODEL 103007415-5208 Hazardous materials RoHS, EU Directive 2002/95/EC Cat. 3 Breaker Frame 225A USER INTERFACE Trip rating 225A Breaker kAIC rating 65kA @ 240V Frequency 50/60 Hz Output Connection Hardwire 3 or 4W + PE UPS interface Activate UPS bypass mode switch Indicator lamps UPS on bypass AC Power to bypass AC Power from UPS AC Power to loads Building interface REPO, 120 V external contact required 1A/1B Aux switch on all breakers INPUT/OUTPUT RATINGS 400V MODEL 103007415-5400 Input Voltage 230/400V: Three-phase Frequency 50/60 Hz Input Connection Hardwire 3P + N + PE Output Voltage 230/400V: Three-phase Frequency 50/60 Hz PHYSICAL CHARACTERISTICS Output Connection Hardwire 3 or 4W + PE 10.5“H x 17.3“W x 29.6“D Control wire harness provided between UPS and breakers Weight: 76 lb/34 Kg ELECTRICAL RATINGS 400V MODEL 103007415-5400 Breaker Frame 225A Trip rating 150A Breaker kAIC rating 25kA @ 480V Front panel with cover removed UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 www.eaton.com/powerquality CANADA Ontario: 416.798.0112 Toll free: 1.800.461.9166 LATIN AMERICA Argentina: 54.11.4124.4000 Brazil: 55.11.3616.8500 Caribbean: 1.949.452.9610 Mexico & Central America: 52.55.9000.5252 South Cone: 54.11.4343.6323 EUROPE/MIDDLE EAST/AFRICA Denmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.0.7841.604.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Portugal: 55.11.3616.8500 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700 Rear view of termination points ASIA PACIFIC Australia: 61.2.9693.9366 New Zealand: 64.0.3.343.3314 China: 86.21.6361.5599 HK/Korea/Taiwan: 852.2745.6682 India: 91.11.4223.2300 Singapore/SEA: 65.6825.1668 Eaton, BladeUPS and Powerware are trade names, trademarks and/or service marks of Eaton Corporation or its subsidiaries and affiliates. ©2009 Eaton Corporation All Rights Reserved Printed in USA BladeUPS04FXA September 2009
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement