2
AllWriter Programmer
Equinox Order Code: SG-ALLWRITER-1
Release Notes
Version 1.00 25th May 1999
Contents
Technical Support……………………………………………………………………………………………………………………….
2
Product Description..……………………………………………………………………………………………………………….……
3
Package Contents………………………………………………………………………………………………………………..………
3
Hardware Overview – The Base Unit………………………………………………………………………………………….………
4
Hardware Overview – The Adaptor...……………………………………………………………………………………….…………
5
Hardware Overview – Match Card……………………………………………………………………………………….…………….
6
Checking Your Computer System………………………………………………………………………………………………..…….
7
Setting up the Hardware…………………………………………………………………………………………………………..…….
7
Installing the Software……………………………………………………………………………………………………………..…….
8
Executing ‘AW.EXE’………………………………………………………………………………………………………….………….
9
Programming Example……………………………………………………………………………………………………….…………
10
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
3
Technical Support
It is often the case that users experience problems when installing or using a product for the first time. Equinox are unable to
answer technical support questions about this product or its use by telephone.
If you have a technical support problem, please consult the following list for help:
This manual
1. On-line help
The help system is context sensitive. Press <F1> for help at any time.
2. Internet Web Site
Further information about this product which may help solving any problems can be found at:
www.equinox-tech.com
3. E-mail
Please e-mail any technical questions about this product to: allwriter@equinox-tech.com
Equinox will try to answer your questions about this product as quickly as possible. However, we can not
promise an immediate reply. Please consult our web site for new software updates as the problem that you are enquiring
about may have already been fixed in a new version.
4. Fax
Please fax any technical support questions about this product to: +44 (0) 1204 535555
Equinox will try to answer your questions about this product as quickly as possible. However, we can not
promise an immediate reply. Please consult our web site for new software updates as the problem that you are enquiring
about may have already been fixed in a new version.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
4
Product Description
The AllWriter Universal programmer was designed mainly for engineering applications. It supports many programmable devices
including EPROM, EEPROM, Flash EPROM, microcontrollers, PLD, CPLD, FPGA etc. The programming system consists of a
base unit and different socket adapters designed to support devices in different packages. Examples are socket adapters for
PLCC, TSOP, SOP, VSOP, QFP, BGA and many other new packages.
The AllWriter can be connected to the PC through the RS-232C serial port or the IEEE1284 parallel port for high speed Remote
Control operation. The user friendly Windows Software allows you to operate the system without consulting the user’s manual.
The unique MatchCard design configures the system to support devices with versatile pin-outs and helps to generate the best
waveform quality. Like other SYSTEM GENERAL programmers, the software upgrades for the AllWriter are free.
Package Contents:
The standard AllWriter package includes:
AllWriter Base Unit
1
DIP 48 Adapter
1
System Diskette (Programmer Driver Software)
2
Power Cable (UK / Euro)
1
RS-232C Serial Port Cable (9-pin)
1
Parallel Port Cable (25-pin)
1
MatchCards
see below
User Manual
on-line
The following MatchCards are supplied with the AllWriter as Standard:
“Match Cards”
Device Support
DIP-48-MEM-00
DIP-48-MEM-01
DIP-48-MOT-00
DIP-48-MOT-01
DIP-48-MPU-00
DIP-48-MPU-01
DIP-48-MPU-02
DIP-48-MPU-03
DIP-48-MPU-04
DIP-48-PIC-00
DIP-48-PLD-00
DIP-48-SER-00
FLASH, EEPROM, EPROM
29F080 / 016, 49F8192, 49B/LV2048
Motorola 68HC705X
Motorola 68HC705X / 711X
Intel 87C, Atmel 87C/ 89S/ 90S
Zilog 86E
Philips 87C/ 89C, Siemens
ST 86E/ 62T/ 62E
Cypress CY7C63xxx/ 37xxx
Microchip PIC
16V8/ 20V8/ 22V10
17C/ 24C/ 25xxx/ 59C/ 93C/ 33C
Please contact Equinox Technologies for further assistance in locating support for a particular device.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
5
Hardware Overview - The Base Unit
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
6
Hardware Overview - The Adaptor
The LED Display
There are three LED’s on the socket adapters. Refer to the description below for their display and status:
LED
Status
Description
ON LINE
Green
Orange
Power-On OK
Power-On Fail
Self Test Fail
PASS/FAIL
Green
Operation Passed
Including:
Self Test OK, DRAM Test OK, Program Passed
Operation in Process
Operation Failed
Including:
Self Test Fail, DRAM Test Fail, Program Fail
Orange
Red
ACTIVE
Red
Flashing Red
Off
Socket operation in progress
Socket waiting for IC insertion. Indicate an enabled socket.
Socket not in operation.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
7
Hardware Overview - MatchCard
What is a MatchCard and how to search for the correct MatchCard?
A MatchCard is a special adapter card which is inserted in the front edge of the socket adapters. Each MatchCard includes
special circuitry required to program a specific device family. Socket adapters with the MatchCard slot must have a MatchCard
inserted in order to program a device. Changing the MatchCard on the socket adapter also changes the configuration of the
programming system and the devices supported. Therefore, be sure to insert the correct MatchCard before you program a
specific device.
If you do not know which MatchCard you need to program a particular device, simply run the AW.EXE and click ‘Chip List
Viewer’ button under Communication Dialog (see example on page 8). A Device Select dialog will allow you to enter the device
number and search the correct MatchCard for you.
Some socket adapters might not have MatchCard slot design. This usually happens on those adapters designed for super finepitched device packages. There is a technical difficulty to route the pins due to the tight pin pitch of the packages.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
8
Checking Your Computer System
Minimum PC requirements:
•
•
•
•
PC 486-33 SX or better.
Microsoft Windows 95, 98
8 MB RAM
4 MB free disk space.
Setting up the Hardware
The AllWriter consists of a base unit and a chosen socket adapter. A MatchCard must be inserted if the socket adapter has a
MatchCard slot. Follow the procedures below to set-up the hardware and install the software:
1.
Make sure that the power is off on the base unit.
2.
Connect Socket Adapter
To connect the socket adapter in the base unit, align the front end of the adapter flush toward the front end of the base unit.
The guiding slots of the 2 female connectors on the base unit will slide into the 2 male connectors on adapters ensuring
correct alignment. Make sure to use both hands to push down the adapter from the front and rear ends evenly for
connection.
Warning! Connecting/Removing the socket adapter with power on the base unit might damage the system.
The socket adapter might have been connected to the base unit when you received your AllWriter. However, the vibration
of transportation might adversely affect the connection between the socket adapter and the base unit. If so, simply follow
the instruction above to reconnect the socket adapter.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
9
3.
Connect the PC Communication port
Choose to connect either the serial port or the parallel port from your AllWriter to
the PC. The software allows you to choose either the serial or parallel communication. To protect your PC and the AllWriter,
make sure to turn the power off on your PC for the port connection.
4.
Connect the power cord
The AllWriter uses a three-pronged mains power cord, which should be fitted in a grounded electric outlet only.
This design is a safety precaution for the programmer operators and a protective measure against possible
ESD damages for the programmer and target devices.
Installing the Software
Follow the procedures below for the software installation:
1.
Insert AllWriter Setup diskette #1 in the floppy driver (Drive A: or Drive B: )
2.
Under Windows, click the Start button at the lower-left corner and select Run
3.
Enter the name of the floppy drive, where you inserted the Setup diskette, followed by ':\setup' (for example, A:\setup). Click
Ok to start.
4.
Follow the instructions on the PC screen until the installation is finished,
5.
Turn the power on AllWriter and wait until the system goes through self-test, calibration. The ON LINE LED will be green to
indicate that the system has passed all tests.
6.
Under Windows, click the AllWriter icon to execute AW.EXE.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
10
Executing AW.EXE
The installation program will automatically create an entry for ‘AW.EXE’ on your desktop Start Menu. Simply click on Start and
point to Programs | AllWriter | AllWriter. Click on AllWriter to launch AW.EXE.
The program AW.EXE enables the communication between the PC and the AllWriter programmer and runs in Demo mode as
well as a stand-alone application if the programmer is not connected.
You can either download the source file from a disk drive or a master device, which already contains the desired source code.
Supported file formats are:
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Intel Hex
Microchip INHX
Tektronix Hex
Motorola S
Signetics Hex
Extended Tekhex
HP 64000 Absolute
Spectrum
TI SDSMAC
ASCII Hex
ASCII Oct
ASCII Binary
Formatted Binary
Binary
The target device can be programmed if the following tasks have been successfully performed:
ü
ü
ü
ü
the connection between the program and the programmer is established
the required device is selected
the source code is loaded
the device to be programmed is plugged into the programmer’s ZIF-socket
(see programming example on next page).
The ‘Chip List Viewer’ within AW.EXE gives information about the supported devices and which MatchCard (see page 6) is
needed for each device.
Screenshot of AW.EXE after launching
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
11
Programming Example
This example explains how to program an Atmel AT90S4414 (AVR) microcontroller.
After installing the software and connecting the AllWriter programmer either to the spare serial or parallel port of your computer
do the following steps:
1.
2.
3.
Launch the AllWriter software from “Start | Programs | AllWriter | AllWriter”.
To find the properly Match Card for the silicon press the <Chip List Viewer> button in the communication window.
Make sure that the Match Card choice in the Device Selection window is set to “all” and
key in the whole silicon number in the Search field (here AT90S4414).
The list now shows the manufacturer, the part number, the adapter needed, the associated Match Card and the silicon
type.
4.
5.
6.
Screenshot of the Chip List Viewer window
Insert the required Match Card into the AllWriter programmer, which must still be powered off!
Make sure that the ZIF-socket is empty and switch on the AllWriter programmer.
Wait a few seconds until the “ON LINE” and “PASS/FAIL”-LED’s are green.
7. From the dialogue box displayed, ensure that the proper connector type is selected and press the <Connect> button
8. After a few seconds connection time, select the AT90S4414 silicon via the “Device | Select Device” menu or use the
associated button on the button bar.
9. Insert the AT90S4414 into the ZIF-socket.
10. Download the program file using the “Data File | Download” menu.
11. Program the device using the item “Program” in the “Device” menu or the program button on the button bar.
12. To end the program session, close the AllWriter software and switch off the AllWriter programmer.
Screenshot of the Menu and Button bar
Note: Please refer to the comprehensive on-line help to get further information about the software and the programmer.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
12
Frequently Asked Questions (FAQ`s)
1.
What versions of windows are supported?
Answer: Microsoft Windows 95, 98, NT4.0 not Microsoft Windows 3.11
2.
What mains power cord does the AllWriter comes with and in which voltage range does it work?
Answer: The AllWriter programmer is supplied with either an EU, an UK or an US standard mains power cord. Simply
attach the two-letter code to the Equinox order code, e.g. SG-ALLWRITER-1-UK for an UK purchase order.
The programmer can be used from 100 V up to 240 V at 50-60Hz.
3.
How do I find out whether the AllWriter supports a particular device?
Answer: Launch the AllWriter software ‘AW.EXE’ (see page 9) and press the <Chip List Viewer> button. Ensure in the ‘Chip
List Viewer’ window that the ‘Adaptor’-, ‘MatchCard’- and ‘Package’-choice (availability varies between different software
versions) is set to ‘All’. Enter the full device part number into the ‘Search’ text field. If the AllWriter supports the device, it will
be listed in the window on right site.
4.
What is a MatchCard?
Answer: A MatchCard is a special adapter card which is inserted in the front edge of the socket adapters. Each MatchCard
includes special circuitry required to program a specific device family. Socket adapters with the MatchCard slot must have a
MatchCard inserted in order to program a device. Changing the MatchCard on the socket adapter also changes the
configuration of the programming system and the devices supported. Therefore, be sure to insert the correct MatchCard
before you program a specific device.
5.
What MatchCards does the AllWriter come with as standard?
Answer: The AllWriter programmer ordered from Equinox Technologies (Order Code: SG-ALLWRITER-1) comes with the
following MatchCards as standard:
6.
“Match Cards”
Device Support
DIP-48-MEM-00
DIP-48-MEM-01
DIP-48-MOT-00
DIP-48-MOT-01
DIP-48-MPU-00
DIP-48-MPU-01
DIP-48-MPU-02
DIP-48-MPU-03
DIP-48-MPU-04
DIP-48-PIC-00
DIP-48-PLD-00
DIP-48-SER-00
FLASH, EEPROM, EPROM
29F080 / 016, 49F8192, 49B/LV2048
Motorola 68HC705X
Motorola 68HC705X / 711X
Intel 87C, Atmel 87C/ 89S/ 90S
Zilog 86E
Philips 87C/ 89C, Siemens
ST 86E/ 62T/ 62E
Cypress CY7C63xxx/ 37xxx
Microchip PIC
16V8/ 20V8/ 22V10
17C/ 24C/ 25xxx/ 59C/ 93C/ 33C
What adaptor does the AllWriter come with as standard?
Answer: It comes with the DIP-48 adaptor suitable for dual-in-line 0.3”/0.6” devices with up to 48 pins.
7.
Can I use generic PLCC/TQFP/SOIC adaptors etc. with the AllWriter?
Answer: Yes. It is possible to insert any standard programming adaptor into the DIP-48 adaptor supplied with the
programmer. For example, to program an 89C51 in PLCC-44 package, insert a PLCC-44 adaptor (Equinox Order Code:
AD-PLCC44-A or equivalent) into the AllWriter DIP-48 adaptor in the same position as you would insert the DIP-40 device.
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941
13
8.
Should I connect the AllWriter to the PC Serial or Parallel?
Answer: Apart from any performance reasons (e.g. speed) is it does not matter whether you choose the spare serial or
spare parallel port to connect the programmer to your computer. The parallel port is likely to be faster for data download to
the programmer.
9.
Where do I get driver software updates from?
Answer: Driver software can be downloaded from the Equinox Technologies web site at:
www.equinox-tech.com
Equinox Technologies UK Limited
UK Contact Details
3 Atlas House, St. Georges Square, Bolton BL1 2HB England
Tel: +44 (0) 1204 529000 Fax: +44 (0) 1204 535555
E-mail: sales@equinox-tech.com Web site: www.equinox-tech.com
US/Canada Contact Numbers
Tel: 1-800-216-1777 Fax: 1-800-234-0941