GENERAL APPLIANCE SPECIFICATIONS FV41 DIRECT VENT GAS FIREPLACE HIGH ALTITUDE INSTALLATION INFORMATION
Add to my manuals2 Pages
advertisement
FV41 DIRECT VENT GAS FIREPLACE
GENERAL APPLIANCE SPECIFICATIONS
HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the
Mendota technical service department for specific venting requirements and venting restrictions.
42
1
2
" M IN.
ROUGH FRAM ING W IDTH
32
1
8
"
9" TO VENT
PIPE CENTER
35-1/2"
49
3
4
"
17
11
16
"
19-1/2" M IN.
DEPTH
17
11
16
"
47" MIN.
16"
M INIM UM ROUGH FRAMING DIMENSIONS
HEIGHT
W IDTH
DEPTH
TO G UIDE EDG E
FROM UNIT BASE
TO ROOM CEILING
FROM UNIT BASE
TO 8" M ANTEL
FROM UNIT BASE TO
UNIT ENCLOSURE CEILING
ADJACENT W ALLS:
A wall perpendicular to and in front of this fireplace's glass door surface must be at least 16 inches from the side edges of the facing guide.
A wall at 45° to the glass surface and starting at this
Fireplace's outer edge is permitted. Projections behind this wall (in shaded area) are permitted.
47"
42-1/2"
19-1/2"
72"
48"
50"
CEILING
8" M ANTEL DEPTH
AT HEIGHTS SHOW N
NON-COMBUSTIBLE ZONE
72" M IN.
TO
ROOM CEILING
47
48" M IN.
UNIT BASE
TO 8" M ANTEL
47" MIN.
ROUGH FRAM ING
HEIGHT
34
7
8
"
42
1
2
" M IN
OPENING W IDTH
DISTANCE FROM
FIREPLACE FACE
70
5
16
"
19
1
8
"
24" MIN
TO VINYL SOFFIT
(18" M IN TO W OOD
OR M ETAL SOFFIT)
50" MIN.
UNIT FLOOR
TO ENCLOSURE
CEILING
42-1/2"
TO CENTERLINE
OF VENT CAP
18"
17"
16"
15"
14"
13"
12"
11"
10"
9"
8"
7"
6"
5"
4"
3"
2"
1"
0"
1
1
2
" HEARTH PAD HEIGHT
(M IN R-1 RATING)
IS REQUIRED!
18" m in. Non-com bustible Hearth protection required [SEE HEARTH
PROTECTION PAD R-RATING, PAGE 12]
CAUTION: The distance from floor level to the centerline of the vent cap is given based on Sim pson Duravent GS components. If using vent com ponents of other brands do not assume that the m easurement given here is applicable. Verify the distance to centerline of vencap by m easuring the com ponents you will be using.
NOTE: For every 1" this fireplace is raised off the floor, the non-com bustible hearth protection pad m ay be reduced by 2". If this fireplace is raised off the floor more than 6",
No hearth protection pad is required.
NON COMBUSTIBLE FACING
49
3
4
"
9 | P a g e
MANTEL CLEARANCES
Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace.
The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. For ease, however, measure up from the floor level of this fireplace. The chart and diagram, in this page, provide all the reference dimensional information necessary in determining the distance a combustible mantel may protrude out from the face surface of this fireplace. The Chart, at right, shows the Distance from Fireplace Face the combustible mantel may protrude outward at a Distance up From Floor Level of this Fireplace.
If you prefer to take measurements from the Top of the Convection Air Opening, note that the Top of the convection air opening is 30 inches up from the floor level of this fireplace.
WARNING: Make proper use of this chart. Do not compromise the specifications contained in this chart.
Failure to adhere to proper clearances required to combustibles may cause spontaneous combustion of the mantel and may result in a fire causing property damage, personal injury or loss of life.
Figure 1: Mantel Clearances
NON-COMBUSTIBLE ZONE
10 | P a g e