GENERAL APPLIANCE SPECIFICATIONS FV41 DIRECT VENT GAS FIREPLACE HIGH ALTITUDE INSTALLATION INFORMATION

Add to my manuals
2 Pages

advertisement

GENERAL APPLIANCE SPECIFICATIONS FV41 DIRECT VENT GAS FIREPLACE HIGH ALTITUDE INSTALLATION INFORMATION | Manualzz

FV41 DIRECT VENT GAS FIREPLACE

GENERAL APPLIANCE SPECIFICATIONS

HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please contact the

Mendota technical service department for specific venting requirements and venting restrictions.

42

1

2

" M IN.

ROUGH FRAM ING W IDTH

32

1

8

"

9" TO VENT

PIPE CENTER

35-1/2"

49

3

4

"

17

11

16

"

19-1/2" M IN.

DEPTH

17

11

16

"

47" MIN.

16"

M INIM UM ROUGH FRAMING DIMENSIONS

HEIGHT

W IDTH

DEPTH

TO G UIDE EDG E

FROM UNIT BASE

TO ROOM CEILING

FROM UNIT BASE

TO 8" M ANTEL

FROM UNIT BASE TO

UNIT ENCLOSURE CEILING

ADJACENT W ALLS:

A wall perpendicular to and in front of this fireplace's glass door surface must be at least 16 inches from the side edges of the facing guide.

A wall at 45° to the glass surface and starting at this

Fireplace's outer edge is permitted. Projections behind this wall (in shaded area) are permitted.

47"

42-1/2"

19-1/2"

72"

48"

50"

CEILING

8" M ANTEL DEPTH

AT HEIGHTS SHOW N

NON-COMBUSTIBLE ZONE

72" M IN.

TO

ROOM CEILING

47

48" M IN.

UNIT BASE

TO 8" M ANTEL

47" MIN.

ROUGH FRAM ING

HEIGHT

34

7

8

"

42

1

2

" M IN

OPENING W IDTH

DISTANCE FROM

FIREPLACE FACE

70

5

16

"

19

1

8

"

24" MIN

TO VINYL SOFFIT

(18" M IN TO W OOD

OR M ETAL SOFFIT)

50" MIN.

UNIT FLOOR

TO ENCLOSURE

CEILING

42-1/2"

TO CENTERLINE

OF VENT CAP

18"

17"

16"

15"

14"

13"

12"

11"

10"

9"

8"

7"

6"

5"

4"

3"

2"

1"

0"

1

1

2

" HEARTH PAD HEIGHT

(M IN R-1 RATING)

IS REQUIRED!

18" m in. Non-com bustible Hearth protection required [SEE HEARTH

PROTECTION PAD R-RATING, PAGE 12]

CAUTION: The distance from floor level to the centerline of the vent cap is given based on Sim pson Duravent GS components. If using vent com ponents of other brands do not assume that the m easurement given here is applicable. Verify the distance to centerline of vencap by m easuring the com ponents you will be using.

NOTE: For every 1" this fireplace is raised off the floor, the non-com bustible hearth protection pad m ay be reduced by 2". If this fireplace is raised off the floor more than 6",

No hearth protection pad is required.

NON COMBUSTIBLE FACING

49

3

4

"

9 | P a g e

MANTEL CLEARANCES

Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace.

The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. For ease, however, measure up from the floor level of this fireplace. The chart and diagram, in this page, provide all the reference dimensional information necessary in determining the distance a combustible mantel may protrude out from the face surface of this fireplace. The Chart, at right, shows the Distance from Fireplace Face the combustible mantel may protrude outward at a Distance up From Floor Level of this Fireplace.

If you prefer to take measurements from the Top of the Convection Air Opening, note that the Top of the convection air opening is 30 inches up from the floor level of this fireplace.

WARNING: Make proper use of this chart. Do not compromise the specifications contained in this chart.

Failure to adhere to proper clearances required to combustibles may cause spontaneous combustion of the mantel and may result in a fire causing property damage, personal injury or loss of life.

Figure 1: Mantel Clearances

NON-COMBUSTIBLE ZONE

10 | P a g e