Asahi Pentax K 2 camera Service manual
Below you will find brief information for camera K2. The K2 is a 35mm SLR camera with a variety of features, including automatic exposure, manual exposure, and a self-timer. It is designed for photographers of all levels of experience.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
PRODUCT No. 23602
ASAHI PENTAX
SERVICE MANUAL
www.carburetor-manual.com
Would you like some Free Manuals?
http://carburetor-manual.com/free-shop-manual-club-t-13.html
Also visit http://freeshopmanual.com
for more Free Manuals
Also Visit my website for 7 FREE Download Manuals starting with this one.
"The ABC's of Carburetion"
Click Here Now
file:///C|/Documents%20and%20Settings/Tim/Desktop/carburetor-manual-welcome/index.htm[4/25/2009 11:42:20 AM]
B.
Disassembly
There are some parts which have to be taken off with careful treatment.
1.
Top cover (A300) removal
Wind lever should be set at closed position before taking off top cover.
AT CLOSED POSITION
Fig. 1
AT PREADVANCE ANGLE
Fig. 2
2.
Photo sensor circuit board assembly (T300) removal
K2 camera is controlled with very small electric current (ex. 200pA or 300pA), therefore all electric parts should be treated carefully, especially, photo sensor circuit board; it is so sensitive that it should not be touched with bare hands.
23602
Fig. 3
1 /13
3.
P.C. board attern assembly (T100) removal
P.C. board pattern assembly (T100) can be taken out with or without removing Front Board.
Pull it out hooking the large black I.C. with spring hanger. Don't touch the other I.C.s or electric parts.
Fig. 4
4.
Front board removal
Front board can be removed without taking off Self-Timer lever or covering, as shown in photograph.
Fig. 5
5.
Shutter mechanism (E000) removal
Shutter mechanism (E000) is so delicate and sensitive that it should not be touched with bare hands except the parts as shown in the photograph. It may cause malfunctions if handled roughly.
Use finger cover for removal.
Fig. 6
23602
Fig. 7
2 /13
C. Assembly and adjustments
Some parts should be assembled and adjusted. with careful treatment as shown in the following.
1.
Winding stopper assembly (0-C6)
Fig. 8
2.
Winding spring (0-C23)
Face the retainer screw of spring in the direction of Tripod socket, and wind the spring a little and stretch it in the direction of tripod seat. The proper tension is obtained when it is stretched around Tripod socket
Fig. 9
3.
Perforation Adjustment
There are several kinds of 2nd gear (C205) which are selected to achieve the proper position of socket teeth. After removing 2nd gear, set sprocket (C9) in the correct position using the tool
(23600 N-A1, C9-A)
23602
Fig. 10
3 /13
Wind up top 2nd mech. plate assembly (C200) with driver and loosen wind shaft without moving main gear. Then give back-tension to sprocket gear (C16)
Choose the proper coupling 2nd gear (C205) and install it in the above-mentioned way.
Fig. 11
4.
Memory block assembly (T400)
After cocking mirror housing, 02mm clearance is necessary between delrin and the longer contact piece of memoiy block (T400) — See Fig. 12 A
After releasing mirror housing and when mirror stays up, also 02mm clearance is necessary between two contact pieces of memory block. See Fig. 12 B
Fig. 12
5.
Shutter dial seat assembly (F000)
Set shutter dial at “B”, and pull meter coupling plate assembly (0-A8) toward counter dial block.
Otherwise, shutter mechanism will not work properly.
23602 4 /13
6.
Blue needle adjustment
(a) Set shutter dial to “AUTO”. Install Idle gear holder assembly (0-A12) gearing 2/3 portion with the gear of (ga1vanometer (q 1)
Idle gear holder assembly (0-A12) should never touch shaft recept~cle assembly (0-D5), and the clearance is approximately 0.2-0.3mm.
Fig. 13
(b) Pull meter coupling plate assembly (0-A8) toward shaft receptacle assembly (0-D5).
Install rack (A11), attaching its concave part to the rivet of meter coupiing plate assembly (0-
A8).
Three kinds of rack (A11) of different widths are used for adjustment to achieve smooth function of the blue needle.
(c) When shutter dial is turned from “B” to “AUTO” or vice versa, meter- coupling plate attsembly (0-A8) must function must function smoothly even without meter coupling spring
(A15). After checking function, meter coupling spring (A 15) is installed.
(d) Blue needle is adjusted by moving rack (A11) left -or right, so that blue needle matches with each step of shutter speed scale when shutter dial is turned.
(e) Apply red lacquer to screws and Plio-Bond to meter coupling spring (A155) after finishing adjustment.
7.
Stroke adjustment
After putting on top cover (A300) and wind lLever assembly (0-C132), set shutter dial to “B”,
Wind lever should be set at closed position.
23602 5 /13
Procedure
(a) No clearance is allowed between release plate (A503) and the lever of shutter mechanism
(E000). and also the lever should not be pushed by release plate.
(b) After shutter cocking, adjust clearance to 0.3mm between Mirror
Actuator lever hook plate assembly
(0-B48) and its hitting part.
(Adjusting screw 1)
(c) Shutter stroke adjustment
Depressing shutter button gradually, shutter starts working at 2.3mm ±0.2
deep from original position.
(Adjusting screw 2)
(d) Self timer stroke
0.1 mm deeper than shutter stroke
(Adjusting screw 3)
Fig. 14
Fig. 15
8.
Funchon check of SWp
“ON” When release button is gradually depressed and before it reaches to keep-position, SWp should be on”.
“OFF” When wind lever is set at closed position.
When release button is depressed with “Lock”
23602 6 /13
9.
Shutter speed adjustment:
Testers: Light value correction unit. TSST-3A. T adjuster (or battery), ESST-1A, digital counter, diaphragm setting ring (KA-00-lA), 23600K-A400-A.
Fig. 16
Procedure:
(a) Auto speed adjustable resistor R7
(1X, ASA100, 2.8V)
EV12
EV16
—
—
1/60 sec
1/1000
EV16(2X)
EV8
EV4
—
—
—
1/500
1/4
1
(b) Meter level — R10
EVI6 — 1/1000sec
(c) Meter sensitivity — R9
EV8 — 1/4
(d) Manual shutter speed — Rl2
EVI2 — 1/60
(check all shutter speeds to see Rotary SW contact effects)
(e) Battery Checker
2.1V
2.4V
OFF
ON
(No adjustment is allowed because no tester is supplied).
23602
Fig. 17
7 /13
10.
Galvanometer installation
Tester: Meter tester (MA-00-01)
Needle must be absolutely horizontal between 15 and 8. Check the movable range of the needle in the upper and lower part.
Fig. 18
11.
Shutter release adjustment
As shown in Fig. 19, when mirror .housing is released, dimension between Shutter Actuator plate (B61) and minor housing foot. should be kept at 9.4 ±10mm.
The longer Shutter actuotor plate (B61) will break Shutter mechanism (E000), and the shorter one will never make it (E000) function.
23602
Fig. 19
8 /13
D.
Lubricants
G21 —
G31 —
L —
E. Special tools
Mainly used
0-B25, 0-B48, 0-B68, 0-B22
On rewind shaft (D6)
23600K-C135-A
23600K-A316-A
23600K-A340-A
23600K-A19-A
23600K-C8-A
23600K-B40A
23600K-D4-A
23600K-C134-A1
23600K-C134-A2
Fig. 20
23602 9 /13
advertisement
Key Features
- 35mm SLR camera
- automatic exposure
- manual exposure
- self-timer
- meter coupling plate
- galvanometer
- shutter speed adjustment
- stroke adjustment
- blue needle adjustment
- memory block assembly