Contents
Setup Procedures
…………… 2
Batch Setup
…………… 3
Bar Code Setup Menu …………… 5
1 Device Selection and Default
…………… 5
2 Beep and Delay
…... 7
3 Keyboard Wedge
……….. 9
4 RS232 Serial Setting
5 Scanner
...…. 11
………….. 13
7 Symbologies(I): Code 39/I 2 of
5/ S2 of 5/Code 32
.… 15
8 Symbologies(II): Code 128 /
MSI / Code 93 / Codabar /Label
Code
………... 17
9 Symbologies(III): UPC/EAN/
Delta Code
………….. 19
Function Code for PC
.… 21
Function Code for MAC
…. 23
1
Function Code for IBM Terminal
………..… 25
Full ASCII Table
Test Chart
………….. 27
…………………... 33
Setup Procedures
1) Select a group that contains the
parameters to be changed.
2) Scan the “Enter Group” label first,
the Reader will sound 3 beeps to
indicate that Setup has begun.
3) Scan the label representing the
parameter to be changed.
4) Scan the labels representing the
parameter values.
5) Repeat the previous two steps, if
necessary, to change the parameters in
the same group.
6) Scan the “Exit” label to end Setup
for the group currently selected. The
Reader will sound 2 beeps.
7) Repeat the Setup procedure for other
groups that require parameters to be
modified, if necessary.
2
Batch Setup
If more than one scanner needs to be
configured, you can duplicate the
settings of the Master Scanner to the
others. This is done by producing a set
of custom setup labels (derived from
the master scanner) and then scanning
these labels to configure the other
scanners.
The following barcode label is “Dump
Settings”. First, open a text editor
(such as Notepad, Word, etc.), and
then scan Dump Settings. The settings
of the scanner will dump to the screen
as one or several ASCII string(s). You
may use any barcode printing software,
select Code 39 symbology, and use the
output string(s) to generate the barcode
labels. You can then scan these batch
setup labels to duplicate the settings.
Dump Settings
Scanner Configuration Manager
Scanner Configuration Manager is a
utility program to configure scanner
settings on a computer using the
Windows 95/98 operating system. Use
3
the program to define the settings and
then download the parameters to the
scanner. Download the program from
our web site at www.unitech-adc.com.
RS232 Reader
The RS232 reader can be setup with
any modem communication utility such as Windows’ HyperTerminal. To
setup the reader, start your comm.
utility and set the default parameters to
9600-baud rate, 8 bits, and no parity.
Once communication is established,
press both of the “Shift” keys on your
computer keyboard and you will enter
the setup screen. Follow the menu
promptings to change the setup
parameters and save the settings.
4
Bar Code Setup Menu
1 Device Selection and Default
Enter Group 1
Group Default
0
1
2
3
4
5
6
7
8
9
Factory Default
Exit
5
Keyboard Wedge Reader
Device ID
Device Type
00
IBM PC/XT
01
IBM PC/AT, PS/2 model
40, 60, 80 etc.
02
IBM PS/2 Model 25, 56, 70,
90
06
Keyboardless Wedge
(Notebook Computer)
03
Macintosh ADB bus
RS-232 Reader
Device ID
Device Type
04
RS232 Serial Decoder
6
2 Beep and Delay
Enter Group 2
Group Default
0
1
2
3
4
5
6
7
8
9
Exit
7
Beep Tone
(On Decoding):
0
1
2
None
Low
Medium
3
4
5
A1
High
Low to High
High to Low
4
5
6
7
A2
500 ms
1 second
3 seconds
5 seconds
4
5
6
7
A3
10 ms
30 ms
50 ms
100 ms
Inter-Block Delay:
0
1
2
3
0 ms
10 ms
50 ms
100 ms
Inter-Character
Delay:
0
1
2
3
0 ms
1 ms
2 ms
5 ms
8
3 Keyboard Wedge
Enter Group 3
Group Default
0
1
2
3
4
5
6
7
8
9
Exit
9
Function Code:
B1
0
Off
1
Upper/Lower
Case:
0
1
B2
Upper Case
Auto Trace
Lower Case
Language PC/AT
Function Code:
0
1
2
3
4
5
6
7
8
9
:
On
US
UK
Swiss
Swedish
Spanish
Norwegian
Italian
German
French
Alt Key Mode
Danish
10
B3
4 RS232 Serial Setting
Enter Group 4
Group Default
0
1
2
3
4
5
6
7
8
9
Exit
11
Baud Rate:
C1
0
1
2
3
300
600
1200
2400
4
5
6
7
4800
9600
19200
38400
3
4
C2
Space
None
Parity:
0
1
2
Even
Odd
Mark
Data Bit:
C3
0
7
1
8
Handshaking:
0
1
Ignore
RTS Power on
C4
2 RTS Enable
Communication
ACK/NAK
C5
0
Off
1
On
1
On
BCC character:
C6
0
Off
Time Out:
C7
0
1
1 second
3 seconds
2
3
12
10 seconds
Unlimited
5 Scanner
Enter Group 5
0
Group Default
1
2
Exit
Symbology
UPC-A
UPC-E
EAN-13
EAN-8
I 2 OF 5
S 2 OF 5
Code 39
Codabar
Code93
Code 128
UCC/EAN
128
MSI
Code 32
Delta Code
Plessey
Label Code
China Postal
3
PreDefined
A
E
F
FF
I
H
M
N
L
K
]Cl
O
T
D
P
B
C
4
5
6
7
8
9
Data Format:
Preamble Code ID
Length
Terminator
Postamble
13
Data
BCC
Terminator:
D1
0
1
Enter (CR/LF)
Return (LF)
2
3
Field Exit (CR)
None
1
Enable
Code ID:
D2
0
Disable
Define Code ID:
D3
00
01
02
03
04
05
06
07
08
09
Code 39 Full ASCII
Code 39 Standard
EAN-13
UPC-A
EAN-8
UPC-E
I 2 of 5
Codabar
Code128
Code 93
10
11
12
13
14
15
16
17
18
S 2 of 5
MSI Code
EAN128
Code 32
Delta Code
Label Code
Plessey Code
Code 11
China Postal
Double verification:
D4
0
Off
1~7
On (Verify 1~7 times)
Label Type:
D6
0
Positive
1
Positive & Negative
OO
Postamble:
Scan “OO” to program
preamble. Scan characters
from Full ASCII table to
define preamble.
Maximum 16 characters.
Scan “OO” to end.
PP
Preamble:
Scan “PP” to program
preamble. Scan characters
from Full ASCII table to
define preamble.
Maximum 16 characters.
Scan “PP” to end.
14
7 Symbologies(I): Code 39/I 2 of 5/
S2 of 5/Code 32/EAN128
Enter Group 7
Group Default
0
1
2
3
4
5
6
7
8
9
NN Maximum Length
MM Minimum Length
Exit
Code 39:
F1
0/1
4
5
6
7/8
0~48
Disable/Enable
2/3 Full ASCII/Standard
Check Digit Calculate and Send
Check Digit Calculate but Not Send
Check Digit Not Calculate
Send/Not Send Start & Stop
Min length 0 / Max length 48
15
Interleaved 2 of
5:
0/1
2/3
4
5
6
7
8
9
2~64
F2
Disable/Enable
Fix Length On/Off (by first three reads)
Check Digit Calculate and Send
Check Digit Calculate but Not Send
Check Digit Not Calculate
First Digit Suppressed.
Last Digit Not Suppressed.
Not Suppressed.
Min 10 / Max 64
Standard 2 of 5
/ China Postal:
0/1
2/3
4
5
6
1~48
F3
Disable/Enable
Fix Length On/Off
Check Digit Calculate and Send
Check Digit Calculate but Not Send
Check Digit Not Calculate
Min 4 / Max 48
Code 32(Italian
Pharmacy:
0/1
2/3
4/5
F4
Disable/Enable
Leading Character Send / No Send
Trailing Character Send /No Send
Telepen
F5
0/1
Disable/Enable
2/3
Standard/Numeric
UCC/EAN 128:
F6
0/1
2/3
Disable/Enable
Code ID Disable/Enable
16
8 Symbologies(II): Code 128 / MSI /
Code 93 / Codabar /Label Code
Enter Group 8
Group Default
0
1
2
3
4
5
6
7
8
9
NN Maximum Length
MM Minimum Length
Exit
17
Code 128:
G1
0/1
Disable/Enable
1~64
Min 1 / Max 64
MSI/Plessey code:
G2
0/1
4
5
6
1-16
Disable/Enable
2/3 CD Send / No Send
Check Digit Double Module 10
CD Double Module 11 Plus 10
CD Single Module 10
Min 1 / Max 16
Code 93:
G3
0/1
Disable/Enable
1~48
Min 1 / Max 48
Code 11: (Special)
G4
0/1 Disable/Enable
2/3 One/Two CD
4/5 CD Send / No Send
1-48
Min 1 / Max 48
Codabar:
G5
0/1
4
5
6
7/8
3-48
Disable/Enable 2/3 S & S Send / No Send
CD Calculate & Send
CD Calculate but not Send
CD not Calculate
CLSI Format On / Off
Min 3 / Max 48
Label Code IV & V
G6
0/1
Disable/Enable
2/3 Checksum Send/No Send
18
9 Symbologies(III): UPC/EAN/Delta
Enter Group 9
Group Default
0
1
2
3
4
5
6
7
8
9
Exit
19
UPC-A:
H1
0/1
2/3
4/5
Disable/Enable
Leading Digit Send / No Send
CD Send / No Send
UPC-E:
H2
0/1
2/3
4/5
6/7
8/9
Disable/Enable
Leading Digit Send / No Send
CD Send / No Send
Zero Expansion On / Off
Disable/Enable NSC=1
EAN-13:
H3
0/1
2/3
4/5
6/7
Disable/Enable
Leading Digit Send / No Send
CD Send / No Send
Bookland EAN (ISBN)Enable / Disable
EAN-8:
H4
0/1
2/3
4/5
Disable/Enable
Leading Digit Send / No Send
CD Send / No Send
Supplement Code:
H5
0/1
4
6/7
2 Add-on Code
5 Add-on Code
2/3
Off / On
Off / On
Transmitted if Present 5 Must Present.
Space Added / Not Added
Delta Distance
Code:
0/1
2/3
4/5
H6
Disable/Enable
Check Digit Calculated/Not Calculated
Check Digit Send/No Send
20
Function Code for PC
F1 (%VA)
F2 (%VB)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
Cursor Right (/FC)
Cursor Left (/FD)
Cursor Up (/FE)
Cursor Down (/FF)
PgUp (/FG)
PgDn (/FH)
TAB (/FI)
Back Tab (/FJ)
ESC (/FK)
Enter (/FL)
Right Ctrl (/FO)
Right Enter(/FM)
21
Ins (/FW)
Del (/FX)
22
Function Code for MAC
F1 (%VA)
F2 (%VB)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
F13 (%VM)
F14 (%VN)
F15 (%VO)
Cursor Left (/FD)
Cursor Right (/FC)
Cursor Down (/FF)
Cursor Up (/FE)
Page down (/FH)
page up (/FG)
ins (/FJ)
Ttab (/FI)
Enter (/FL)
23
Esc (/FK)
return (/FM)
Option Make (%VP)
Option Break (%VQ)
Control Make (%VR)
Control Break (%VS)
Shift Make (%VT)
Shift Break (%VU)
Apple Make (%VV)
Apple Break (%VW)
24
Function Code for IBM Terminal
F2 (%VB)
F1 (%VA)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
F13 (%VM)
F14 (%VN)
F15 (%VO)
F16 (%VP)
F17 (%VQ)
F18 (%VR)
F19 (%VS)
F20 (%VT)
F21 (%VU)
F22 (%VV)
F23 (%VW)
F24 (%VX)
25
Home (/FA)
End (/FB)
TAB (/FI)
Enter (/FL)
Return (/FM)
Field Exit (/FO)
Field + (/FP)
Field - (/FQ)
RESET (/FV)
26
Full ASCII Table
NUL (%U)
SOH ($A)
STX ($B)
ETX ($C)
EOT ($D)
ENQ ($E)
ACK ($F)
BEL ($G)
BS ($H)
HT ($I)
LF ($J)
VT ($K)
FF ($L)
CR ($M)
SO ($N)
SI ($O)
DLE ($P)
DC1 ($Q)
DC2 ($R)
DC3 ($S)
DC4 ($T)
NAK ($U)
SYN ($V)
ETB ($W)
27
CAN ($X)
EM ($Y)
SUB ($Z)
ESC (%A)
FS (%B)
GS (%C)
RS (%D)
US (%E)
SP
! (/A)
” (/B)
# (/C)
$
%
& (/F)
’ (/G)
( (/H)
) (/I)
* (/J)
+
, (/L)
-
.
/
28
0
1
2
3
4
5
6
7
8
9
: (/Z)
; (%F)
< (%G)
= (%H)
> (%I)
? (%J)
@ (%V)
A
B
C
D
E
F
G
29
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[ (%K)
\ (%L)
] (%M)
^ (%N)
_ (%O)
30
` (%W)
a (+A)
b (+B)
c (+C)
d (+D)
e (+E)
f (+F)
g (+G)
h (+H)
i (+I)
j (+J)
k (+K)
l (+L)
m (+M)
n (+N)
o (+O)
p (+P)
q (+Q)
r (+R)
s (+S)
t (+T)
u (+U)
v (+V)
w (+W)
31
x (+X)
y (+Y)
z (+Z)
{(%P)
| (%Q)
} (%R)
~ (%S)
DEL (%T)
32
Test Chart
EAN-13
3 045214 834123
EAN-8
8012 3453
UPC-A
0
47669 13716
6
UPC-E
99
0 123457 2
ISBN 957-630-239-0
00270
9 789576 302398
33
W+ E + D + G + E
Code 39 with C/D
UNI T E C H- E
Interleaved 2 of 5
0987654321
Codabar
A2 2 3 5 7 0 0 0 5 9 9 8 7 6 B
MSI
12345- 5
34