International Controls & Measure ICM450C 6-1/2 in. 3-Phase Voltage Monitor Installation manual
International Controls & Measure ICM450C is a programmable three-phase voltage monitor designed to protect motors from premature failure and burnouts. It monitors line voltage, load voltage (optional), phase unbalance, over/under voltage, phase loss, and phase reversal. The ICM450C features a 25-fault memory, adjustable fault interrogation delay, and a delay on break timer. It has a universal input voltage range of 190-630 VAC and a frequency range of 50-60 Hz. The output is a relay with a voltage range of 240 VAC at 10 A maximum.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
ICM 450 Programmable Three Phase Voltage Monitor with 25-Fault Memory Protects motors from premature failure and burnouts Installation, Operation & Application Guide For more information on our complete range of American-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com Specification Input •Line Voltage: Universal, 190-630 VAC •Frequency: 50-60 Hz •Load Side Monitoring: Optional •Control Voltage: 18-240 VAC •Frequency: 50-60 Hz Output •Type: Relay, SPDT •Voltage Range: 240VAC @ 10A maximum •Frequency: 50-60 Hz Control Operating Temperature •Operating Temperature: -40ºF to +167ºF (-40ºC to +75ºC) •Storage Temperature: -40ºF to +185ºF (-40ºC to +80ºC) LCD Operating Temperature •Operating Temperature: -4ºF to +167ºF (-20ºC to +75ºC) Mechanical •Mounting: Surface mount using (2) #8 screws •Terminations: Screw terminals •Weight: 12 ounces (341 grams) Dimensions •6 1/2” L, 4 1/4” W, 1 3/8” H (16.5 cm. L, 10.8 cm. W, 3.5 cm. H) Parameters Phase Unbalance Protection •Voltage Unbalance: 2-20% adjustable Over/Under Voltage Protection •Under Voltage: 2-25% adjustable •Over Voltage: 2-25% adjustable Phase Loss Protection •Phase Loss Condition: Equals 25% of nominal for any given phase; system will shut down and a fault will be recorded should this occur Delay on Break Timer •Control Voltage: 18-240 VAC •Time Delay: 0 to 10 minutes adjustable Fault Interrogation Delay •Time Delay: 0 to 15 seconds adjustable •Provides a delay between fault detection and system shutdown - helps to eliminate nuisance trips or unnecessary shutdowns Caution Installation of the ICM450 shall be performed by trained technicians only. Adhere to all local and national electric codes. Disconnect all power to the system before making any connections. Installation 1.Using (2) #8 screws, mount the ICM450 in a cool, dry, easily accessible location in the control panel. 2.Connect voltage as shown in Figure 1 (below). Leave existing line and load side connections intact on the contactor. 3.Load side monitoring is optional (unit may be used to monitor line side only). Wire the contactor and optional control voltage monitoring as in Figures 2 and 3 (below). Note: Load/line wire must be rated for 3-phase voltage rating, 20ga minimum. 4.Upon application of power, the ICM450 will be on line and will begin to monitor the system. Figure 1 Incoming 3-phase voltage from load or “back” side of contactor (optional) LOAD 3 LOAD 2 LOAD 1 LINE 3 LINE 2 LINE 1 Incoming 3-phase voltage from line or “front” side of contactor The incoming 3-phase voltage is used to power up the ICM450 as well (190-600) Figure 2 •Terminals 1 and 3 are the control signal input terminals •“Control Mode” is turned ON or OFF in setup 6 5 4 •With “Control Mode” set to “ON,” there must be a 3 voltage present on terminals 1 and 3 for the relay output terminals 4 and 6 to close; this voltage can be supplied from a thermostat, pressure switch, etc. •When the voltage on these terminals is re-applied, * Switch can be thermostat, the unit will not re-energize until the delay on break apressure (0-10 minutes) time has elapsed switch, etc. •Use of terminals 1 and 3 is optional; they will be Control Voltage (18-240 VAC) ignored if the “Control Mode” is set to “OFF” 1 Short pins when using 24 VAC control voltage Figure 3 6 5 4 3 1 •Terminals 4 and 6 are “dry,” normally open contacts •Terminals 4 and 6 are closed when power is within specifications •Terminals 4 and 6 open when there is a fault condition or loss of control signal Contactor Coil Contactor Voltage (18-240 VAC) ICM450 Wiring Diagrams 2-Pole Contactor 3-Pole Contactor L03 LI3 LI1 LINE LINE LINE 3 2 1 LOAD LOAD LOAD 3 2 1 LOAD LOAD LOAD 3 2 1 LINE LINE LINE 3 2 1 LI1 LI2 Control Voltage Control Voltage L01 L01 L02 L02 LI2 LI3 L03 * Thermostat, pressure switch, etc. * Thermostat, pressure switch, etc. L0AD L0AD Setting the Parameters 1. 2. 3. 4. Press the green SETUP button to enter Setup mode. Setup LED will light. Use the and arrows to change user parameters. Scroll through setup by pressing and releasing the SETUP button. When the last parameter has been set, the phase average will be displayed and the Setup LED will automatically turn OFF. Button Functions Press arrows to scroll through and select user parameter settings in Setup mode. HOLD down for fast edit. Press to enter Setup mode and select user parameters. Hold for voltage display a b, b c, a c (simultaneously). Press to read faults. Hold for 5 seconds to clear faults and reset memory. Parameters Parameter Line Voltage Delay On Break Description Average phase to phase line voltage Range 190-600 Amount of time between 0-10 the load de-energizing and minutes re-energizing Default 208 .1 minute Recommended Nameplate Voltage 4 minutes** Fault Interrogation Amount of time before the load de-energizes due to a non-critical fault* 0-15 seconds 15 seconds 7-8 seconds** % Over/Under Voltage Maximum/minimum phase to phase average voltage, respectively 2-25% 20% 12-15%** % Phase Unbalance Amount of allowable voltage unbalance 2-20% 20% 4-5%** Reset Mode AUTO or number of times the load can be re-energized after a load side fault before a manual reset is necessary Note:When monitoring line side only, the reset mode will always be AUTO AUTO, 0-10 AUTO AUTO Control Mode With control mode set to OFF, the load will energize if no 3- phase fault conditions exist; with control mode ON, the load will energize if no fault conditions exist and control voltage is present at terminals 1 and 3 of the ICM450 ON or OFF ON Based on wiring * Non-critical faults are faults such as High/Low Voltage and Phase Unbalance. Critical faults, such as Phase Loss and Phase Reversal, have a fault interrogation of under 2 seconds and it is not user adjustable. ** For best recommendations, consult manufacturer of equipment. Fault Conditions Press and release fault button to scroll through all saved faults. Note: For initial setup, press and hold FAULT for 5 seconds to remove any previously stored faults. Fault Problem Corrective Action Back Phase Loss Not all three of the phases on the load side are present 1. Re-energize the contactor. 2. If the fault reappears after the load energizes: a. Turn all power OFF b. Check all load side connections c. Check the contacts of the contactor for debris or excess carbon. Back Phase Rev Loads 1, 2, or 3 are not in sequence (not 120º phase shifted) 1. Turn OFF all power. 2. Swap any 2 phases on the load side of the ICM450 only (example: swap load 1 and load 2) * 3. Re-apply power. Back Phase Unbal A voltage unbalance between the three load phases exceeds the unbalance setpoint 1. Press the READ button to observe the present load voltages. Check system for unbalance cause. 2. Increase the fault interrogation time if necessary. 3. Increase the percent unbalance setting if necessary. Front Over Volt Average phase-phase voltage exceeds the maximum percentage 1. Check system for over-voltage cause. 2. Increase the percent over-voltage setting if necessary. 3. Increase the fault interrogation time if necessary. Front Phase Loss Not all three of the phases on the line side are present 1. Press and hold the READ button on the phase monitor or use an AC voltmeter to carefully measure all three phase-phase line voltages (example: Line 1 Line 2, Line 2 Line 3, Line 3 Line 1). 2. Repair the missing phase. Front Phase Rev Lines 1, 2, or 3 are not in sequence (not 120º phase shifted) 1. Turn OFF all power. 2. Swap any 2 phases on the line side of the ICM450 (example: swap load 1 and load 2)* 3. Re-apply power. Front Phase Unbal A voltage unbalance between the three line phases exceeds the unbalance setpoint 1. Press the READ button to observe the present load voltages. Check system for unbalance cause. 2. Increase the fault interrogation time if necessary. 3. Increase the percent unbalance setting if necessary. Front Under Volt Average phase-phase voltage is below the minimum percentage 1. Check system for under-voltage cause. 2. Increase the percent under-voltage setting if necessary. 3. Increase the fault interrogation time if necessary. * Only swap phases during initial setup, not after the ICM450 has been in operation without errors. Troubleshooting Problem LCD Readout Load will not energize LED Status Corrective Action Phase Avg. All LEDs Off Confirm that the control input (terminals 1 & 3) is properly connected and configured (see Pages 1 and 3) Load will not energize Phase Avg. Load LED Off, Fault LED blinking Press FAULT to observe the current fault; correct the condition of the first fault that appears (see Fault Conditions, Page 4 for a list of corrective actions) Fault LED blinks repeatedly while load is energized Phase Avg. Fault LED Blinking, Load LED On Indicates there are faults saved in the memory, press FAULT rapidly to scroll through saved faults; to clear the faults, press and hold FAULT for more than 5 seconds Load will not de-energize when control voltage is OFF Phase Avg. Load LED On, Control LED Off The control mode setting is OFF; press SETUP to get to the control mode. Press to set the control mode ON Setup LED is on while load is being energized Anything Other Than Phase Avg. Setup LED On, Load LED On To exit the setup mode, press either READ or FAULT Load will not energize Reset Fault LED Blinking Unit in lockout; maximum number of retries in manual reset mode has been reached; to reset unit, press FAULT and hold for more than 5 seconds Load turns ON and OFF repeatedly Readout is Irrelevant Fault LED Blinking Fix load side fault; press FAULT to observe condition; the delay on break period may be too short; press SETUP to enter the delay on break mode; press to lengthen the delay ONE-YEAR LIMITED WARRANTY The Seller warrants its products against defects in material or workmanship for a period of one (1) year from the date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a non-case credit for the purchase prices of the goods which are provided to be defective. The warranty and remedies set forth herein do not apply to any goods or parts thereof which have been subjected to misuse including any use or application in violation of the Seller’s instructions, neglect, tampering, improper storage, incorrect installation or servicing not performed by the Seller. In order to permit the Seller to properly administer the warranty, the Buyer shall: 1) Notify the Seller promptly of any claim, submitting date code information or any other pertinent data as requested by the Seller. 2) Permit the Seller to inspect and test the product claimed to be defective. Items claimed to be defective and are determined by Seller to be non-defective are subject to a $30.00 per hour inspection fee. This warranty constitutes the Seller’s sole liability hereunder and is in lieu of any other warranty expressed, implied or statutory. Unless otherwise stated in writing, Seller makes no warranty that the goods depicted or described herein are fit for any particular purpose. 7313 William Barry Blvd., North Syracuse, NY 13212 (Toll Free) 800-365-5525 (Phone) 315-233-5266 (Fax) 315-233-5276 www.icmcontrols.com LIA164-4
advertisement