SPC-530

Rackmount Server PC

User's Manual

Copyright Notice

This document is copyrighted, April 2000, by Advantech Co., Ltd. All rights are reserved. Advantech

Co., Ltd. reserves the right to make improvements to the products described in this manual at any time without notice.

No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties which may result from its use.

Acknowledgments

SPC-530MB, SPC-530BP, SPC-530MB-U2C, SPC-530BP-U2C series and PCA-6120P4,

PCA-6119P7, PCA-6119P17, PCA-6120DP4, PCA-6118DP7 series are trademarks of Advantech Co.,

Ltd.

NOTE:

The information in this document is provided for reference only. Advantech does not assume any liability arising out of the application or use of the information or products described herein. This manual is subject to change without notice.

Part No. 2002053000 1st Edition

Printed in Taiwan April 2000

Contents

Chapter 1 General Information ................................................................... 1

1.1 Introduction ................................................................................................................. 1

1.2 Model list ................................................................................................................... 1

1.3 Specifications ............................................................................................................ 1

1.4 Dimensions ................................................................................................................ 4

Chapter 2 System Setup ............................................................................. 5

2.1 Removing the cover .................................................................................................... 5

2.2 Removing the handles ................................................................................................ 6

2.3 The cooling fans ......................................................................................................... 6

2.5 Temperature setting .................................................................................................... 7

2.4 Installing the disk drives .............................................................................................. 7

2.6 Installing the power supply unit .................................................................................... 8

Appendix A Backplanes (Optional) ................................................................................... 9

Appendix B Exploded Diagrams .................................................................................... 12

Appendix C Safety Instructions ....................................................................................... 14

Chapter 1 General Information

1.1 Introduction

The SPC-530MB / SPC-530BP, the PC/AT-compatible computer, is designed for high-reliability applications. Not only easily installed and maintained in mission critical applications and harsh environments, it is also a high-end rackmount fault-resilient server PC. The SPC-530BP can be fitted with a 20-slot

PC-bus compatible passive backplane. The SPC-530MB can be fitted with an ATX motherboard. Both the SPC-530BP and SPC-530MB provide one 400-watt ATX redundant power supply and three hot-swap cooling fans. They accept up to six front-access half-height disk drives.

The SPC-530BP / SPC-530MB features an advanced fault detection and alarm notification system to monitor its own hardware status. If your PC system shuts down without advance warning, this can be dangerous and may cause considerable loss.

1.2 Model list

M o d e l N a m e B a c k p l a n e

2 0 s l o t p a s s i v e b a c k p l a n e

R e d u n d

4 0 0 w a t t a n t ,

A T

H o t s w a p

X A C D C P S U

Y E S S P C 5 3 0 B P

S P C 5 3 0 M B

* * * ( R e s

A T e r

X v e t h e m o t h e r s p a c e b o a r d f o r

)

S P C 5 3 0 B P U 2 C 2 0 s l o t p a s s i v e b a c k p l a n e

S P C 5 3 0 M B U 2 C

* * * ( R e s e r v e

A T X m o t h e t h e r s p a c e b o a r d f

) o r

Y E S

Y E S

Y E S

S C S I

R A I D

U l t r a 2

C a r d

W i d e w / c a b l e

D i s k x 5

C a s e t s r t r i d g e s

-

-

Y E S

Y E S

-

Y E S

Y E S

The SPC-530BP-U2C and SPC-530MB-U2C include five disk cartridges installed in vertical disk drive space. There is one horizontal disk drive space reserved for other storage drives such as a CD-ROM drive.

1.3 Specifications

Construction: Heavy-duty steel chassis

Disk drive capacity: Five half-height front-access drives (vertical), and one half-height drive (horizontal)

Cooling system: Three 86 CFM cooling fans inside the chassis

Controls: Power On/Off switch on power supply module in front panel. Alarm reset button, ATX soft switch and system reset button on the front panel

Indicators: Bicolor LEDs (green and red) for power failure, fan failure and overheating. LED indicator (green) for system power On/Off

Buzzer: One buzzer for audio alarm / volume control on board

Dimensions: 19" (W) x 8.75" (H) x 26" (D), 482 mm (W) x 222 mm (H) x 660 mm (D)

Net weight: SPC-530MB / SPC-530BP: 46.2 lb (21 kg)

SPC-530 User's Manual 1

Paint color: Front panel: Pantone Black 4C 2X; Chassis: Brushed finish, Ni

Operating temperature: 0 to 50 o C (32 to 122 o F)

Relative humidity: 20 to 90%

CE compliant

Hot-swap AC-DC 400-watt ATX redundant power supply (RPS-400ATX)

Output rating: 400 watts (max.)

Input voltage: 90 to 132 V

AC

or 180 to 264 V

AC

@ 47 ~ 63 Hz, switchable

Output voltages: +5 V @ 42 A, +3.3 V @ 20 A, +12 V @ 14 A, -5 V @ 1 A, -12 V @ 1 A

+5 Vsb @ 0.75 A (+5 V / +3.3 V; Total: 210 watts)

Minimum load: +5 V @ 2 A, +3.3 V @ 0.3 A, +12 V @ 0.5 A

MTBF: 100,000 hours at 25 o C, 70% load

Safety: UL/C-UL/TUV/CE approved

Passive backplane options (for SPC-530BP / SPC-530BP-U2C)

B a c k p l a n e M o d e l N a m e

P C A 6 1 2 0 P 4

P C A 6 1 1 9 P 7

P C A 6 1 1 9 P 1 7

S l o t s p e r S e g m e n t

1 5 I S A / 4 P C I / 1 P I C M G

1 1 I S A / 7 P C I / 1 P I C M G

1 I S A / 1 7 P C I / 1 P I C M G

S e g m e n t ( s )

S i n g l e

S i n g l e

S i n g l e

RAID card features (only for SPC-530BP-U2C / SPC-530MB-U2C)

The SPC-530 is available with a RAID to PCI host interface. This gives users numerous extra features.

(For more details, please refer to our RAID manual, under SPC-530BP-U2C / SPC-530MB-U2C)

• One/Two Ultra2 Wide SCSI (68-pin) channel(s) on-board

• Automatic bad sector reassignment, Bad Sector Management

• Built-in SCSI terminator

• RAID 0, 1 (0+1), 3, 5

• Auto-rebuilding

• Hot-spare drive operation

• Disk hot-swapping

• Self-diagnostics

• Complete OS support: MS-DOS, Windows 95/98, Windows NT, NetWare, OS/2, SCO UnixWare,

Sun Solaris and Linux

2 SPC-530 User's Manual

Fault detection and alarm notification

Power failure: This operates only when you have installed the redundant power supply

(RPS-400ATX). If either of the two power modules fails, the dedicated LED (PWR) changes color from green to red, and an audio alarm also sounds. The dedicated LED remains red for the failed power module until it is fixed.

Fan failure: If any of the three cooling fans fails, the dedicated LED changes color from green to red, and an audio alarm also sounds. The dedicated LED remains red for the failed fan until it is fixed.

The fan assembly can be hot-swapped if any fan fails.

High temperature: If the chassis interior temperature exceeds 65 o C (149 o F) (standard setting), the

LED changes color from green to red, and an audio alarm also sounds. The LED remains red until the temperature drops below 63 o C.

Temperature select: The temperature threshold can be adjusted to one of four readings, by setting the switch on the alarm board: 65 o C (default setting), 55 o C, 70 o C and 75 o C.

Audible alarm: A buzzer on board is activated (continous beep) as soon as a malfunction is detected, and sounds until the alarm reset button is pressed. The alarm reset button is on the front panel.

However, the alarm indicator will stay red until the fault condition is resolved.

Self-test: Press the alarm reset button for 8 seconds, and the alarm board will self-test automatically for all functions. The alarm board can also monitor the temperature's sensor IC. If the sensor has failed, or there is no connection, the buzzer will sound a " Beep x Beep x ..." alarm.

Controls for the system

The SPC-530 series' front panel provides one soft switch and one system reset button to re-boot the PC system. See the following figure:

SPC-530 User's Manual 3

1.4 Dimensions

SPC-530BP (Can be fitt ed with a 20-slot backplane)

Unit = mm

SPC-530MB (Can be fitt ed with a 12" x 13" motherboard)

4 SPC-530 User's Manual

Chapter 2 System Setup

The SPC-530 series is an ATX-compatible computer designed for industrial applications. This rugged chassis meets the EIA RS-310C 19" rackmount standard.

Setting up your SPC-530 series requires only a screwdriver and a small amount of time. Before you begin, you should also gather together all of the cards you plan to install, as well as the disk drives you plan to use.

WARNING: Disconnect all power from the chassis before you install the CPU cards. Unplug the power cord from the wall,

Do not just turn off the power switch. If you are not sure what to do, take the job to an experienced professional.

2.1 Removing the cover

There are screws near the top, along the sides, and on the rear to secure the cover to the chassis.

Remove them, and then you can lift the cover free of the chassis. See Figure 2.1 below:

2.1 Removing the cover

SPC-530 User's Manual 5

2.2 Removing the handles

The handles and mounting ears for the front panel can be removed as follows. Please see Figure 2.2

below:

2.2 Removing the handles

2.3 The cooling fans

There are three cooling fans inside the chassis. To replace or service the fans, open the top cover as in

Figure 2.1. Loosen the thumbscrews, and pull out the whole fan assembly. Please refer to Figure 2.3

below:

6 SPC-530 User's Manual

2.3 Cooling fans

2.4 Installing the disk drives

1. Open the top cover as in Figure 2.1. There is one independent disk drive bay on the front of the chassis. Remove the four outer screws which mount the drive bay to the chassis. Slide the drive bay toward the rear of the chassis, and lift it free of the chassis. See Figure 2.4 below.

2. Remove the front cover of the drive bay, and insert the drives into their proper locations in the drive bay. See Figure 2.5.

2.4 Removing the disk drive bay 2.5 Inserting the drives into the drive bay

2.5 Temperature setting

If the chassis interior temperature exceeds 65 o C (149 o F) (default setting), the LED changes color from green to red. There is also an audio alarm. The LED remains red until the temperature drops below

63 o C.

The default of the "RF_JMP" is PIN1-2: ON, which enables redundant power detection.

Temperature can also be selected (via SW1) on the alarm board inside the chassis:

SW1

1

OFF

OFF

ON

ON

2 TEMP

OFF 65 o C

ON 55 o C

OFF 70 o C

ON 75 o C

2.6 Alarm board

SPC-530 User's Manual 7

2.6 Installing the power supply unit

There is one 400 W ATX redundant power supply installed at the front of the chassis. The power module can be hot-swapped for maintainence .

2.7 ATX redundant power supply

8 SPC-530 User's Manual

Appendix A Backplanes (Optional)

PCA-6120P4 Rev. A1: 15 ISA / 4 PCI / 1 PICMG-slot passive backplane

Dimensions: 420 x 260 mm

Termination resistor signals

The termination resistors provide an impedance mismatch at the end of the bus, to prevent signal reflections. This mismatch has to be balanced by the capability of the CPU and optional cards to electrically drive the load imposed by the resistor.

Resistor Signals Resistor Signals

RN1, RN8

RN4, RN11

SA7-SA0

SA15-SA8

RP1, RP2

RN2, RN12

MEMW, SMEMR, IOW, IOR

SBHE, LA23-LA17

RN5, RN10

RN3, RN9

SD0-SD7

SD8-SD15

RN6, RN7 SA19-SA16

SPC-530 User's Manual 9

PCA-6119P7 Rev. A1: 15 ISA / 4 PCI / 1 PICMG-slot passive backplane

Dimensions: 420 x 260 mm

10 SPC-530 User's Manual

PCA-6119P17 Rev. A1: 1 ISA / 17 PCI / 1 PICMG-slot passive backplane

Dimensions: 420 x 260 mm

SPC-530 User's Manual 11

Appendix B Exploded Diagrams

SPC-530MB

12 SPC-530 User's Manual

SPC-530BP

SPC-530 User's Manual 13

Appendix C Safety Instructions

1.

Please read these safety instructions carefully.

2.

Please keep this User's Manual for later reference.

3.

Please disconnect this equipment from any AC outlet before cleaning. Do not use liquid or sprayed detergent for cleaning. Use a moist sheet or cloth.

4.

For pluggable equipment, the socket-outlet must be installed near the equipment and must be easily accessible.

5.

Please keep this equipment free from humidity.

6.

Lay this equipment on a reliable surface when installed. A drop or fall could cause damage.

7.

The openings on the enclosure are for air convection, so protect the equipment from overheating.

DO NOT COVER THE OPENINGS.

8.

Make sure of the voltage of the power source when connecting the equipment to the power outlet.

9.

Position the power cord such that people cannot step on it. Do not place anything over the power cord.

10.

All cautions and warnings on the equipment must be noted.

11.

If the equipment is not used for a long time, disconnect it from the mains. This prevents the equipment from being damaged by transient overvoltage.

12.

Never pour any liquid into an opening. This can cause fire or electrical shock.

13.

Never open the equipment. For safety reasons, the equipment should only be opened by qualified service personnel.

14.

If one of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged.

b. Liquid has penetrated into the equipment.

c. The equipment has been exposed to moisture.

d. The equipment does not work well or you cannot get it to work according to the user's manual.

e. The equipment has been dropped or damaged.

f. The equipment has obvious signs of breakage.

15.

DO NOT LEAVE THIS EQUIPMENT IN AN UNCONDITIONED ENVIRONMENT WITH

STORAGE TEMPERATURES BELOW -20 o C (-4 o F) OR ABOVE 60 o C (140 o F), AS THIS

MAY DAMAGE THE EQUIPMENT.

The sound pressure level at the operator's position according to IEC 704-1:1982 is equal to or less than

70 dB(A).