- Industrial & lab equipment
- Electrical equipment & supplies
- Electrical connection
- Power extensions
- Samlex America
- SA-2000K-124
- Specification
Samlex America SA-2000K-112 2000 Watt Pure Sine Wave Inverter Specifications
Add to my manuals
1 Pages
advertisement
2 YEAR LIMITED WARRANTY
OUTPUT
INPUT
POWER SAVE
(SLEEP MODE)
DISPLAY
REMOTE
OPERATION
PROTECTIONS
COOLING
COMPLIANCE
ENVIRONMENT
DIMENSIONS
WEIGHT
MODEL NO.
OUTPUT VOLTAGE
OUTPUT FREQUENCY
TYPE OF OUTPUT WAVEFORM
TOTAL HARMONIC DISTORTION OF OUTPUT WAVEFORM
CONTINUOUS OUTPUT POWER (At Power Factor = 1)
SURGE OUTPUT POWER (At Power Factor = 1)
PEAK EFFICIENCY (At full load)
AC OUTPUT CONNECTIONS
NOMINAL DC INPUT VOLTAGE
DC INPUT VOLTAGE RANGE
DC INPUT CURRENT AT NO LOAD (Power Save on)
DC INPUT CURRENT AT NO LOAD (Power Save off)
DC INPUT CONNECTIONS
ENABLED / DISABLED BY SWITCH
INPUT VOLTAGE, OUTPUT POWER, STATUS
WIRED REMOTE CONTROL (Simple version) (Optional)
WIRED REMOTE CONTROL (Upgraded version) (Optional)
LOW DC INPUT VOLTAGE ALARM
LOW DC INPUT VOLTAGE SHUTDOWN
HIGH DC INPUT VOLTAGE SHUTDOWN
SHORT CIRCUIT SHUTDOWN
OVERLOAD SHUTDOWN
GROUND FAULT SHUTDOWN
OVER TEMPERATURE SHUTDOWN
REVERSE POLARITY ON DC INPUT SIDE
FORCED AIR COOLING
SAFETY
EMI / EMC
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
(L X W X H), MM
(L X W X H), INCHES
KG
LBS
NOTE: Specifications are subject to change without notice
2000W
Model
DC-AC Inverter
Pure Sine Wave
SA-2000K-112
12 VDC-120 VAC
SA-2000K-124
24 VDC-120 VAC
Design Features
- Pure sine wave output (THD < 3%)
- Switch selectable output frequency: 50 / 60 Hz
- Switch selectable Power Save Mode wherein the inverter shuts off non essential circuitry and reduces its no load self consumption till it sees a minimum programmed load
(40 - 280 Watts)
- Optional wired remote controls for switching and monitoring the operation. Includes Ignition Lockout and
Reverse Over-ride Function (ROF)
- Input and output are fully isolated
- Advanced micro-controller
- 2 load controlled cooling fans save power consumption
- 3 tri-color LEDs display operational status and fault indications
SA-2000K-112 SA-2000K-124
120 VAC, +/- 5%
50 / 60 Hz +/- 0.05% (Selected by Switch)
Pure Sine Wave
< 3%
2000 W 2000 W
4000 W for 3 sec
89%
4000 W for 3 sec
92%
Dual NEMA5-20R receptacles with GFCI protection; Terminal strip for hardwiring
12 VDC
10.5 to 15 VDC, +/- 0.2 VDC
0.6 A
2.8 A
24 VDC
21 to 30 VDC, +/- 0.4 VDC
0.3 A
1.5 A
M-8 bolt and nut / Wire with M-8 ring lug terminal
Wake up power: 40 to 280 W (switch selectable)
By steady / flashing patterns of three, 3- color LEDs
SR-6-12 with 10 ft cable
SR-8 with 10 ft cable
SR-6-24 with 10 ft. cable
10.5 VDC, +/- 0.2 VDC
10.0 VDC, +/- 0.2 VDC
15.0 VDC, +/- 0.2 VDC
21.0 VDC, +/- 0.4 VDC
20.0 VDC, +/- 0.4 VDC
30.0 VDC , +/- 0.4 VDC
Yes
Yes
Yes. Only for the GFCI protected dual NEMA5-20R receptacles
Yes
Yes. Internal fuses will blow
2 load controlled fans: ON > 300W ; OFF < 160W
Meets UL-458
Meets FCC Part 15(B), Class A
0 oC to + 40 oC
- 30 oC to 70 oC
422 x 208 x 166
16.6 x 8.18 x 6.53
9
19.8
12003-SA-2000K-112-124-0715