Pre-Construction Wall Mount Kit for APAD
Installation Guide
Crestron PMK-1000L Pre-Construction Wall Mount Kit
Contents
Pre-Construction Wall Mount Kit: PMK-1000L 1
All brand names, product names and trademarks are the property of their respective owners.
©2008 Crestron Electronics, Inc.
Installation Guide - DOC. 6061A Contents • i
Crestron PMK-1000L Pre-Construction Wall Mount Kit
Pre-Construction Wall Mount Kit:
PMK-1000L
Description
The PMK-1000L is a pre-construction mount kit for the Crestron ® APAD LCD controller. The PMK-1000L is used for installation on a stud. For custom controller placement without a stud, use the TMK/WMKT-1000L or MMK/WMKM-1000L.
The PMK-1000L includes a 12-inch long, 18 AWG jumper wire to secure controller cabling prior to drywall installation and to avoid damaging the cables when the opening is routed. Refer to the physical views of the PMK-1000L shown on the following page. The table that follows lists all parts included with the PMK-1000L.
NOTE: This mounting kit is to be used only with the APAD LCD controller.
Supplied Hardware for the PMK-1000L
DESCRIPTION PART QUANTITY
Metal, Plate, Pre-Construction
Metal, Plate, Cover
Screw, #04-40 x 2”, Pan, Phil
Jumper wire, 12”, 18 AWG, Black
4505161
2004826
2018793
2007838
1
1
4
1
Installation Guide - DOC. 6061A Pre-Construction Mount Kit: PMK-1000L • 1
Pre-Construction Wall Mount Kit Crestron PMK-1000L
The dimensions of the PMK-1000L are shown below.
Dimensional Drawing
1.50 in
(3.81 cm)
1.00 in
(2.54 cm)
7.31 in
(18.57 cm) 3.74 in
(9.49 cm)
0.06 in
(0.16 cm)
5.77 in
(14.66 cm)
3.95 in
(10.02 cm)
#04-40 TAPPED HOLE IN
EACH CORNER
SECURE 18 AWG
JUMPER WIRE IN NOTCH
TO HANG CABLES AWAY
FROM CUTTING TOOLS
FOR
DRYWALL
NAILS OR
SCREWS
(NOT
INCLUDED)
7/16 in
(12 mm)
FOR DRYWALL SCREWS (NOT INCLUDED)
FOR DRYWALL NAILS (NOT INCLUDED)
4 3/8 in
(112 mm)
3 1/2 in
(89 mm)
1/2 in
(13 mm)
7/16 in
(12 mm) 1/16 in
(2 mm)
3 11/16 in
(94 mm)
4 3/8 in
(112 mm)
4 9/16 in
(116 mm)
Dimensional Drawing - Cover Plate
4.74 in
(12.03 cm) 0.03 in
(0.08 cm)
4.65 in
(11.82 cm)
2 • Pre-Construction Mount Kit: PMK-1000L Installation Guide - DOC. 6061A
Crestron PMK-1000L
Setup
Pre-Construction Wall Mount Kit
Mounting
The PMK-1000L consists of a single metal plate, which fastens to the stud of a framed wall prior to hanging drywall. Standard drywall nails or screws to attach the
PMK-1000L are not supplied (length can vary).
The plate is designed to provide the necessary support for a single controller and can mount to the right or left side of a stud. Confirm that the PMK-1000L is level before applying drywall.
Mounting the PMK-1000L
PMK-1000L
PRE-CONSTRUCTION
MOUNTING PLATE
(4505161)
Installation Guide - DOC. 6061A
NOTE: BE SURE THE
PLATE IS LEVEL WHEN
MOUNTED.
CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity
above and below the controller for heat dissipation.
After drywall is positioned, a rectangular opening must be made. Position the opening to expose the #40-40 tapped holes in each corner.
NOTE: Cut the drywall along the inside edge of the front of the mounting plate.
The labels on the front of the mounting plate indicate the perimeter of the opening that should be cutout. Refer to the NOTE in “Mounting the PMK-1000L” shown on the illustration above.
Pre-Construction Mount Kit: PMK-1000L • 3
Pre-Construction Wall Mount Kit Crestron PMK-1000L
Mounted View with Cover Plate (Mounting Example Prior to Drywall Installation)
STUD
PRE-CONSTRUCTION
MOUNTING PLATE (4505161)
MUST BE LEVEL BEFORE
APPLICATION OF DRYWALL
DRYWALL
SCREWS (4) #04-40 X 2"
PAN HEAD (2018793)
METAL PLATE COVER (2004826)
TO COVER CUTOUT IN DRYWALL
BEFORE CONTROLLER IS
INSTALLED (MAY BE REQUIRED BY
LOCAL BUILDING CODES)
NOTE: MOUNTING PLATE IS TO BE
COVERED WITH DRYWALL AND THEN
THE CUTOUT MADE AROUND THE
INSIDE OF THE OPENING. BE SURE TO
LEAVE THE FOUR TAPPED HOLES ON
THE FRONT OF THE BOX EXPOSED TO
ACCEPT THE MOUNTING SCREWS.
NOTE: The four tapped holes on the front of the mounting plate must be exposed to accept the controller mounting screws. These holes are found beneath the drywall just outside the four corners of the opening made by cutting out the drywall. Refer to the NOTE in “Mounted View with Cover Plate” illustration above.
Installation
Complete the installation by either installing the controller, leaving the hole open (if permitted by local building codes) or installing the optional cover plate with the included #04-40 x 2” screws. If the controller is to be installed, refer to the latest revision of the APAD Installation and Operations Guide (Doc. 6455) for installation instructions. The document is available from the Crestron website
( http://www.crestron.com/manuals ). Refer also to the comprehensive illustration on the following page.
4 • Pre-Construction Mount Kit: PMK-1000L Installation Guide - DOC. 6061A
Crestron PMK-1000L
Controller Mounting – Exploded View
Pre-Construction Wall Mount Kit
PMK-1000L
DRYWALL
APAD
MOUNTING SCREWS
(4) #04-40 X 2
(2018793)
APAD
Installation Guide - DOC. 6061A Pre-Construction Mount Kit: PMK-1000L • 5
Pre-Construction Wall Mount Kit Crestron PMK-1000L
Other Mounting Option Accessories
If too much of the mounting plate is exposed after the drywall is cut, you may need to patch the area. Crestron provides the following accessories:
• MMK-1000L (Doc. 6062) - for larger repairs and to fill in larger irregularities around the opening (requires plastering).
• TMK-1000L (Doc. 6063) - for smaller repairs and to provide a smooth edge at the opening. This option provides a finished appearance and is preferred when wallpaper is hung.
The manuals for the MMK-1000L and TMK-1000L are available from the Crestron website.
6 • Pre-Construction Mount Kit: PMK-1000L Installation Guide - DOC. 6061A
Crestron PMK-1000L
Resources
Pre-Construction Wall Mount Kit
Industry Compliance
As of the date of manufacture, the PMK-1000L has been tested and found to comply with specifications for CE marking marking.
Reference Documents
The latest version of all documents mentioned within the guide can be obtained from the Crestron website ( http://www.crestron.com/manuals ). This link will provide a list of product manuals arranged in alphabetical order by model number.
List of Related Reference Documents
DOCUMENT TITLE
APAD Wall Mount LCD Controller
MMK-1000L Mud Mount Kit
TMK-1000L Trim Ring Mount Kit
Further Inquiries
If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876].
For assistance in your local time zone, refer to the Crestron website
( www.crestron.com/offices ) for a listing of Crestron worldwide offices.
You can also log onto the online help section of the Crestron website
( www.crestron.com/onlinehelp ) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features.
Future Updates
As Crestron adds improvements to the PMK-1000L additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column.
Installation Guide - DOC. 6061A Pre-Construction Mount Kit: PMK-1000L • 7
Pre-Construction Wall Mount Kit Crestron PMK-1000L
Return and Warranty Policies
Merchandise Returns / Repair Service
1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON dealer. Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address.
2. Products may be returned for credit, exchange or service with a CRESTRON Return
Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J. or its authorized subsidiaries, with
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA.
3. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from
CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered.
This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any.
CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse, accidental damage, modification or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced or removed.
This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall
CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty.
Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supersedes all previous warranties.
Trademark Information
All brand names, product names and trademarks are the sole property of their respective owners. Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP/Vista and WindowsNT/2000 are trademarks of Microsoft Corporation.
8 • Pre-Construction Mount Kit: PMK-1000L Installation Guide - DOC. 6061A
Crestron PMK-1000L Pre-Construction Wall Mount Kit
This page is intentionally left blank.
Installation Guide - DOC. 6061A Pre-Construction Mount Kit: PMK-1000L • 9
Crestron Electronics, Inc.
15 Volvo Drive Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576 www.crestron.com
Installation Guide – DOC. 6061A
(2002105)
01.08
Specifications subject to change without notice.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project