- Home
- Domestic appliances
- Small kitchen appliances
- Kitchen scales
- Mettler Toledo
- ID7sx-Sys 22008168A
- Operating instructions
advertisement
▼
Scroll to page 2
of 34
Operating instructions METTLER TOLEDO MultiRange ID7sx-Sys weighing terminal www.mt.com/support Contents ID7sx-Sys Contents Page Operating instructions 22016401 1 Safety precautions ....................................................................... 4 2 2.1 2.2 2.3 2.4 2.5 2.6 Introduction and commissioning ................................................... Documentation ............................................................................. Applications ................................................................................. ID7sx-Sys weighing terminal.......................................................... Commissioning ............................................................................ Cleaning...................................................................................... Disposal ...................................................................................... 5 5 5 6 8 8 8 3 3.1 3.2 3.3 3.4 3.5 Basic functions ............................................................................ 9 Setting to zero .............................................................................. 9 Taring ......................................................................................... 9 Weighing ..................................................................................... 10 Working with several weighing platforms......................................... 10 Displaying versions ...................................................................... 11 4 4.1 4.2 4.3 Additional functions ..................................................................... Display ID code and test weighing platform ..................................... Recall information......................................................................... Recall data from Alibi Memory........................................................ 12 12 13 14 5 5.1 5.2 5.3 5.4 5.5 Settings in the master mode ........................................................ Overview of the master mode ......................................................... Operating the master mode ............................................................ TERMINAL master mode block........................................................ SCALE master mode block ............................................................. INTERFACE master mode block ...................................................... 17 17 18 20 22 25 6 What to do if....? ......................................................................... 27 7 7.1 7.2 Technical data and accessories .................................................... 29 Technical data.............................................................................. 29 Accessories.................................................................................. 31 8 Index .......................................................................................... 33 06/09 3 Safety precautions 1 ID7sx-Sys Safety precautions The ID7sx-Sys weighing terminal is approved for operation in zone 1 and 21 hazardous areas. It may only be used in areas in which the causes of static electricity build-up, which lead to propagating brush discharges, have been eliminated. If the ID7sx-Sys weighing terminal is used in hazardous areas, special care must be taken. The code of practice is oriented to the "Safe Distribution" concept drawn up by METTLER TOLEDO. Competence ▲ The weighing system may only be installed, maintained and repaired by authorised METTLER TOLEDO service personnel. ▲ The mains connection may only be connected or disconnected by the owner’s electrician. Ex approval ▲ For the exact specification please refer to the statement of conformity. ▲ No modifications may be made to the terminal and no repair work may be performed on the modules. Any weighing platform or system modules that are used must comply with the specifications. Non-compliant equipment jeopardises the intrinsic safety of the system, cancels the Ex approval and renders any warranty or product liability claims null and void. ▲ The safety of the weighing system is only guaranteed when the weighing system is operated, installed and maintained in accordance with the respective instructions. ▲ Also comply with the following: – the instructions for the system modules – the regulations and standards in the respective country – the statutory requirement for electrical equipment installed in hazardous areas in the respective country – all instructions related to safety issued by the owner ▲ The explosion-protected weighing system must be checked to ensure compliance with the requirements for safety before being put into service for the first time, following any service work and every 3 years, at least. Operation ▲ Prevent the build-up of static electricity. Therefore: – always wear suitable working clothes when operating or performing service work on the system, – do not rub or wipe off the keyboard surface with a dry cloth or glove. ▲ Do not use protective hoods. ▲ Prevent damage to the weighing terminal. Hairline cracks in the keyboard membrane are also considered damage. 4 Operating instructions 22016401 06/09 Introduction and commissioning ID7sx-Sys 2 Introduction and commissioning 2.1 Documentation These operating instructions describe the operation of the ID7sx-Sys with the basic functions of the Sys-690 application software and all the possible interfaces. Information on your customer-specific ID7sx-Sys application can be found in the corresponding operating instructions specially authored for you. 2.2 Applications With the ID7sx-Sys weighing terminals the following applications are possible: 2.2.1 ID7sx-Sys with PSU power supply unit RS232 CL ID7sx CL I/O PSU K...x / DN...x/ PUA...x/PTA...x Point Ex system solution PBA430x/ Analog scale In this configuration the following possibilities are available: • Multi-scale operation with up to 3 weighing platforms (K...x, DN...x, PUA...x, PTA...x, PBA430x or system solution Point Ex) • Up to 2 data interfaces and one I/O interface – for printing, – for data exchange with a computer, – for control, e.g. of valves or flaps. • Alibi memory module for storing the individual configuration data as well as weighing data. Operating instructions 22016401 06/09 5 Introduction and commissioning 2.2.2 ID7sx-Sys ID7sx-Sys with PSUx power supply unit ID7sx PSUx Only one weighing platform (K...x, DN...x, PUA...x, PTA...x, PBA430x or Point Ex system solution) is permissible in this configuration. 2.3 2.3.1 ID7sx-Sys weighing terminal Display 1 2 MODE 3 4 5 6 7 6 1 Weight display BIG WEIGHT® with sign and decimal point 2 Stability monitor: lights up until the weighing platform has levelled out, then the weight unit appears here 3 Range display for multi-range weighing platforms 4 Number of the weighing platform: shows the weighting platform just selected 5 Symbol * for identifying weight values in the second unit or in a higher resolution 6 NET symbol for marking net weight values 7 Assignment of the function keys Operating instructions 22016401 06/09 Introduction and commissioning ID7sx-Sys 2.3.2 Keypad 1 CODE A ... CODE D keys – enter identification data 2 FUNCTION CHANGE key – display additional functions when entering weight values: switch over unit 3 INFO key – recall memory contents and system information 4 Function keys F1 … F6 – the current assignment is shown in the display above the key 5 SCALE key – select scale 6 ZERO-SET key – set scale to zero, test scale 7 TARA key – tare scale 8 TARE SPECIFICATION key – enter known tare values numerically 9 CLEAR key – clear entries and values 10 ENTER key – accept and transfer data 11 Numeric keypad with decimal point and signs Operating instructions 22016401 06/09 7 Introduction and commissioning 2.4 2.4.1 2.5 ID7sx-Sys Commissioning Control drawings and guides for installers The explosion-protected weighing system with the ID7sx-Sys weighing terminal may only be installed according to the respective guide for installers and the accompanying control drawing, depending on the power supply unit. Component Guide for installers Control drawing ID7sx ME-22008316 PSU ME-22006472 PSU-ID7sx ME-22006478 PSUx/230V ME-22006386 PSUx/230V-ID7sx ME-22006397 PSUx/120V ME-22006395 PSUx/120V-ID7sx ME-22006399 Cleaning DANGER OF SHOCK ➜ Do not open ID7sx-Sys weighing terminal to clean. CAUTION ➜ Make sure that unused connection sockets are covered with the corresponding protective caps. Ensure the correct position of the seals when doing so. ➜ Do not use high-pressure cleaners. Cleaning ➜ Wipe off ID7sx-Sys weighing terminal with a commercially available glass or plastic cleaner. ➜ When used in category 2, zone 21 hazardous areas, the weighing terminal must be cleaned regularly. See also standard EN 50281-1-1 / 50281-1-2. 2.6 Disposal In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of with domestic waste. This also applies to countries outside the EU, per their specific requirements. ➜ Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection. 8 Operating instructions 22016401 06/09 Basic functions ID7sx-Sys 3 Basic functions 3.1 Setting to zero Setting to zero corrects the influence of minor dirt on the load plate. In the case of excessive dirt which cannot be compensated by setting to zero, the display shows OUT OF RANGE. Manual zero set 1. Relieve weighing platform. 2. Press ZERO-SET key. The display shows 0.000 kg. Automatic zero set 3.2 3.2.1 On certified weighing platforms the zero point of the weighing platform is automatically corrected when the weighing platform is relieved. The automatic zero set can be switched off in the master mode on non-certified weighing platforms. Taring Manual taring 1. Place empty container on scale. 2. Press TARE key. The tare weight is saved and the weight display set to zero. The display shows the NET symbol. Notes • When the weighing platform is relieved, the saved tare weight is displayed with a negative sign. • The weighing platform only saves one tare value. 3.2.2 Enter numerically Specify tare weight This function is only available when ordered expressly. 1. Press TARE SPECIFICATION key. 2. Enter tare weight (container weight) and confirm with ENTER. When weighing platform is relieved, the entered tare weight is displayed with a negative sign. Note With the FUNCTION CHANGE key you can select the weight unit for entering the tare weight. Correct entry Operating instructions 22016401 ➜ Clear the entry character by character with CLEAR key and repeat correctly. 06/09 9 Basic functions ID7sx-Sys 3.2.3 Recall currently saved tare weight The saved tare weight can be recalled at any time. ➜ Enter INFO, TARE SPECIFICATION key sequence. The saved tare weight is displayed. 3.2.4 Clear tare weight ➜ Relieve weighing platform and tare. – or – ➜ Recall tare weight and press CLEAR key. 3.3 Weighing without taring Weighing with taring Weighing ➜ Lay weighing sample on weighing platform. Gross weight (total weight) is displayed. 1. Place the empty container on the weighing platform and tare. 2. Pour in weighing sample. The display shows the net weight and the NET symbol. Weighing with tare specification 1. Place filled container on weighing platform. The display shows the gross weight (total weight). 2. Specify tare weight or recall tare memory. The display shows the net weight (container content) and the NET symbol. 3.4 Working with several weighing platforms Up to 3 weighing platforms can be connected to the ID7sx-Sys. Depending on the setting in master mode, only the currently active scale appears in the display (serial Multi-scale mode) or all scales are operated at the same time (parallel multi-scale mode). A constantly updated sum scale is also available in parallel multi-scale mode. 3.4.1 Switch over weighing platform The weighing platform currently selected is shown on the terminal. ➜ Press SCALE key. The next weighing platform is selected. – or – ➜ Enter number of weighing platform and press SCALE key. The desired weighing platform is selected. Note The sum scale can only be operated non-verifiably. It is therefore identified by the symbol Σ. 10 Operating instructions 22016401 06/09 Basic functions ID7sx-Sys 3.5 Displaying versions When connected to a power supply, the versions of the ID7sx-Sys and the installed components are displayed. Version code for the ID7sx-Sys with customer-specific application program METTLER-TOLEDO ID7sx-Sys ID7sx 0.13 CC-AA-XXXXXXXX-WV-DD.MM.YYYY CC AA XXXXXXXXXX VVV DD.MM.YYYY Operating instructions 22016401 06/09 Country code, e.g. DE = Germany Software type, e.g. 00 = Base Order No. Software version Date of manufacture, day.month.year 11 Additional functions 4 ID7sx-Sys Additional functions The assignment of the 6 function keys of the ID7sx-Sys weighing terminal differs depending on the weighing task. The current assignment is shown above the function keys. Independent of the customer specific application software, the ID7sx-Sys has the following additional functions: 4.1 INFO MODE Display information, see 4.2 Activate master mode, see Chapter 5 Display ID code and test weighing platform Each time the weighing platform configuration is changed the ID code counter is increased by 1. On certified weighing platforms the displayed ID code must match the ID code on the ID code sticker, otherwise the calibration is no longer valid. Display ID code ➜ Press ZERO SET key and hold until IDENTCODE = ... appears in the display. Test weighing platform ➜ Press ZERO SET key again. The connected weighing platform is checked. The display shows CHECK SCALE and then SCALE IS OK after completing the test. Note If weighing platform is defective, display shows SCALE ERROR. 12 Operating instructions 22016401 06/09 Additional functions ID7sx-Sys 4.2 Recall information On the weighing terminal memory contents and system information can be recalled. 1. Press INFO key. Then the following function key assignment appears: DATE TARE SCALE ALIBI END VERS Display date and time Display tare weight Call up the data of the current scale: Version, max. load, ID code, etc. Recall content of alibi memory, see section 4.3. This selection only appears when Alibi Memory-ID7sx is installed. Exit information mask Display version numbers of installed software modules W&M PERFO ERROR Display checksum of the software relevant to calibration. The correct checksum is documented in the calibration approval. System utilisation Fault / Event memory display 2. Select desired information. The information is displayed for about 5 seconds, then the weighing terminal changes to the weighing mode again. Note When several values are displayed, the ID7sx-Sys automatically changes to the next value after approx. 5 seconds. Operating instructions 22016401 06/09 13 Additional functions ID7sx-Sys 4.3 Recall data from Alibi Memory With the Alibi-Memory-ID7sx memory module you can fulfill your recording obligations in certified operation without having to archive paper. Alibi-Memory-ID7sx automatically assigns every weighing operation a consecutive data record number that also appears on the printout, saves the net and tare value and also the date and the time. The Alibi-Memory-ID7sx operates according to the principle of a ring memory: When the capacity limit of 12 Mbytes is reached, the oldest record block having the size of 64 Kbytes is deleted and overwritten by the data of the subsequent weighings. By entering suitable search criteria you can quickly access the data of a very specific weighing. 4.3.1 Initiate ➜ Press INFO, ALIBI key sequence. The function keys change to the following assignment: 4.3.2 FIND >>... < > ->Num END Enter search criteria Search for next matching data record starting with oldest Show the data record of the weighing carried out directly beforehand Show the data record of the weighing carried out directly afterwards Search for data record with known data record number Exit Info Alibi and return to normal mode Fast search with entry of data record number 1. Press ->Num key. 2. Enter number of data record to be searched for and confirm with ENTER. Alibi-Memory-ID7sx now searches for the desired data record. Notes • The search may take up to 10 seconds. • If no data record with the entered number is found, the message NO MATCHING DATA RECORD appears. 14 Operating instructions 22016401 06/09 Additional functions ID7sx-Sys 4.3.3 Search with other search criteria ➜ Press FIND key. The function keys are given the following assignment: DATE TIME NET TARE START END Enter date as search criterion Enter time as search criterion Enter net value as search criterion Enter tare value as search criterion Start search with entered search criteria Terminate search All offered search criteria can be combined with each other. The entered search criteria are shown in the display in clear text. This enables you to search for a find a specific weighing. Enter date ➜ Press DATE key and enter complete date in DD.MM.YY form. Enter time ➜ Press TIME key and enter desired time in one of following formats. Format HH all weighings between HH.00.00 and HH.59.59 are found Format HH.MM all weighings between HH.MM.00 and HH.MM.59 are found Format HH.MM.SS only the weighing at the time HH.MM.SS is found Enter net/tare value 1. Press NET or TARE key. 2. Enter weight value and confirm with ENTER. The function key assignment changes back again for selection of the search criteria. Note With the FUNCTION CHANGE key you can select the weight unit for entering the tare weight. Start search ➜ Press START key. Alibi-Memory-ID7sx searches for the oldest data record which meets the entered search criteria. Notes • The search may take up to 10 seconds. • If no data record with the entered values is found, the message NO MATCHING DATE RECORD appears. • If no search criterion has been entered, the oldest data record is displayed. Operating instructions 22016401 06/09 15 Additional functions ID7sx-Sys 4.3.4 Displaying data records Found data records are shown in the display. DATE: NUM: NET: TARE: Scroll forward/back 02.04.06 000987 25.000 KG 100.346 KG TIME 09.25.25 The keys >>..., < and > enable you to scroll within the found data records. Note When, during scrolling with the key >>... all entries of the Alibi-Memory-ID7sx have been searched through, the message END OF FILE appears. 16 Operating instructions 22016401 06/09 Settings in the master mode ID7sx-Sys 5 Settings in the master mode 5.1 Overview of the master mode In the master mode you adapt the ID7sx-Sys weighing terminal to meet your needs. Depending on the configuration, the master mode is divided into 4 or 5 master mode blocks, which are in turn divided into further blocks. TERMINAL PAC For system settings, such as entering the date and time or loading permanent texts, see section 5.3. To set application-specific parameters. SCALE To select one of the connected weighing platforms. For each selected weighing platform the parameters are then set which concern the weight value, e.g. stability detector, unit, etc., see section 5.4. INTERFACES To select an interface. The communication parameters are then set for each interface, see section 5.5. SERVICE For configuring the weighing platform(s). On IDNet weighing platforms only for METTLER TOLEDO service technicians. On weighing platforms with an analog signal output, see service manual A/D converter Point ME-22004256. Operating instructions 22016401 06/09 17 Settings in the master mode 5.2 5.2.1 ID7sx-Sys Operating the master mode Enter the master mode 1. Press MODE key. If the current function keys assignment does not contain MODE, press the FUNCTION CHANGE key as often as necessary until the MODE key appears. 2. Enter personal code if configured. The display shows the first master mode block TERMINAL. 5.2.2 Assignment of function keys in the master mode Assignment on the top level On the top level of the master mode the function keys are assigned as follows: ← → ↑ END OK Change to previous block within a level Change to next block within a level Exit level and return to higher-level block Exit the master mode and return to normal mode Recall lowerlevel block or confirm selection ➜ Select the function by pressing the function key. When the function keys are otherwise allocated ➜ Press the FUNCTION CHANGE key repeatedly until the function key assignment shown above appears. Example 5.2.3 Example 18 ➜ Press the END key to exit the master mode and return to the normal mode. Orientation in the master mode For improved orientation the display shows the last steps in the path of the current master mode block. The upper 3 lines of the display show the following path for selecting the language: Operating instructions 22016401 06/09 Settings in the master mode ID7sx-Sys 5.2.4 Entries in the master mode The following basic rules apply to entries made in the master mode: • Confirm (alpha)numeric entries with ENTER. • Alphanumeric entries with the ID7sx-Sys: see below. • To accept the displayed value: Press ENTER key. Enter alphanumeric identification 1. Press one of the keys CODE A … CODE F. The functions keys are given the following assignment: ABCDE FGHIJ KLMNO PQRST UVWXY Z/-() Selection of letters A to E Selection of letters F to J Selection of letters K to O Selection of letters P to T Selection of letters U to Y Selection of letter Z or a special character 2. Select desired group of letters, e.g. press KLMNO key. 3. Select desired letter. The display changes again to the above selection. 4. Repeat entry in steps 2 and 3 for additional characters. Note Letters and numbers can be combined as desired. 5.2.5 Emergency entrance into the master mode If a personal code has been assigned for entering the master mode and you have forgotten your code, you can still enter the master mode: ➜ Enter the character sequence C, L, E, A, R as your personal code. Operating instructions 22016401 06/09 19 Settings in the master mode 5.3 5.3.1 Legend 5.3.2 RESET TERMINAL ID7sx-Sys TERMINAL master mode block Overview of the TERMINAL master mode block In the TERMINAL master mode block you enter the following system settings: Blocks highlighted in grey are described in detail in the following. Settings in the TERMINAL master mode block Reset all terminal functions to the factory setting • Resets the password MINIMUM to the factory setting: 2234 • LANGUAGE LANGUAGE German Select dialog language Possible setting: English, Deutsch, Français, Nederlands, Italiano, Español, Polski, Russian, Slovakian, Portuguese, Hungarian, Slovenian, Czech, Croatian LAYOUT MFII KEYBOARD Select keyboard layout of connected external keyboard This setting is not available at ID7sx-Sys. It is available at IND690 only. 20 Operating instructions 22016401 06/09 Settings in the master mode ID7sx-Sys DATE / TIME Enter date and time • Enter DATE in European notation: Day.Month.Year. • Enter TIME in European notation: (24) Hours.Minutes.Seconds. Comments • Enter single-place numbers with a preceding zero. • The clock continues to run after the terminal is switched off. APPL. BLOCK Editing application blocks Assign application blocks or combinations of application blocks to keys or change key assignments for application blocs. This setting is not available at ID7sx-Sys. PERSONAL CODE Codes for entering various master mode menus Enter codes with a maximum of 8 alphanumeric characters. MINIMUM Access to master mode GENERAL Access to all personal codes PAC Access to the PAC / RESET PAC and PAC / ERROR-INFO menus PAC-DATAB. Access to the PAC / DATABASE menu PAC-APPL. Access to the PAC / APPLICATION menu INTERFACE Access to all parameters in the INTERFACE menus; the test functions are freely accessible OPTION 1 OPTION 2 OPTION 3 Program dependent Comment If only zeros are entered, the password is not used MODE SCALES Select between serial and parallel operating mode for the connected scales SCALES SERIAL Serial operation of the connected scales: Only the weight value of the current scale is displayed. SCALES PARALLEL Parallel operation of the connected scales: All weight values of the connected scales are displayed simultaneously. SUM SCALE A sum scale can be defined in parallel scale operation. 1. SUM SCALE: Select ACTIVATED. 2. With , change to SCALE 1 and select YES with < or > if this scale is to be the sum scale. 3. Repeat the procedure for SCALE 2 - SCALE 3. Factory setting: SUM SCALE DEACTIVATED Operating instructions 22016401 06/09 21 Settings in the master mode 5.4 ID7sx-Sys SCALE master mode block In the first block the weighing platform is selected: SCALE 1 … SCALE 3. The other setting possibilities are the same for all connected weighing platforms. 5.4.1 Overview of the SCALE master mode block ... Legend • Blocks highlighted in grey are described in detail in the following. • Factory settings are printed in bold print. • Blocks which only appear under certain conditions have a dotted outline. 22 Operating instructions 22016401 06/09 Settings in the master mode ID7sx-Sys 5.4.2 RESET SCALE Settings in the SCALE master mode block Reset weighing platform to factory setting WEIGHING-PROC ADAPT VIBRATION ADAPTER STABILITY DETECTOR AUTOZERO RESTART universal weighing average conditions ASD = 2 on off WEIGHING-PROC ADAPT Adapt weighing platform to weighing sample UNIVERSAL WEIGHING For solid bodies, coarse filling or checkweighing (factory setting). STATIC WEIGHING For solid bodies and weighing under extreme conditions, e. g. strong vibrations or weighing animals. FINE FILLING For liquid or powdered weighing samples. VIBRATION ADAPTER Adapt weighing platform to the vibration influences of the environment AVERAGE CONDITIONS Factory setting. EXTREME CONDITIONS The weighing platform operates more slowly, however is less sensitive, e. g. suitable with building vibrations and vibrations at the weighing location. IDEAL CONDITIONS The weighing platform operates very quickly, however is very sensitive, e. g. suitable with very calm and stabile weighing location. STABILITY DETECTOR Adapt automatic stability detector Possible settings: ASD = 0 Stability detector switched off (only possible with non-certified weighing platforms) ASD = 1 fast display good reproducibility ASD = 2 ▲ ▼ (factory setting) ASD = 3 ▲ ▼ ASD = 4 slow display very good reproducibility AUTOZERO Switch automatic zero-point correction on or off The automatic zero-point correction corrects the weight of minor dirt with the weighing platform unloaded. Factory setting: AUTOZERO ON Operating instructions 22016401 06/09 23 Settings in the master mode RESTART ID7sx-Sys Switch restart function on or off When RESTART ON is set, the zero point and tare value remain stored after the power supply is interrupted. When the weighing platform is switched on again, the terminal shows the current weight. Factory setting: RESTART OFF DISPLAY UPDATE Set display speed of the weight display Select number of updates per second (UPS). Possible values: 6, 10, 15, 20 UPS Comments • This block only appears when the DISPLAY UPDATE function is supported by the connected weighing platform. • The possible settings are dependent on the connected weighing platform. 24 Operating instructions 22016401 06/09 Settings in the master mode ID7sx-Sys 5.5 Select the interface connection Possible interface types INTERFACE master mode block ➜ Select the interface connection in the first block: COM1 through COM7. • SERIAL Only for COM1 (standard) and COM5 (optional). A corresponding slotcard interface has to be installed for each channel in the PSU/..Ex in order to ensure communication in the secure area (RS232 or CL20mA). The wiring is described in the Guide for installers. For additional settings, see Page 25. • 4 I/O and RELAY BOX 8 Only for COM6. The module designation has been retained for reasons of compatibility. In reality only the optional 8 I/O module on which the functionalities "4 I/O" and "Relay box 8" are mapped exists. For addtitional settings see Page 26. • 8 I/O Only for COM6. Alternative dialog for the 8 I/O interface. • PROFIBUS-DP Only for COM1 and COM5. An ID7sx Profibus module has to be connected at the PSU/..Ex via RS232. This is a top-hat rail module with an external 24-V supply voltage. • ALIBI MEMORY Only for COM7. An Alibi-Memory-ID7sx must be installed in the ID7sx. No further settings are required in the master mode. SERIAL Parameters of the standard COM interface driver for serial interfaces. Some parameters are not editable (dependent on the program) SWITCH ON/OFF Switches the function of this driver on or off. MODE Changes interface parameters. BAUDRATE Possible settings: 150, 300, 600, 1200, 2400, 4800, 9600 Baud PARITY Possible settings: Parity even, Parity odd, No parity DATABITS Possible settings: 7 databits, 8 databits STOPBITS Possible settings: 1 stopbit, 2 stopbits PROTOCOL Possible settings: Non, XonXoff, CL-Handshake END-CHARACTERS Possible settings: End-character 1, end-character 2 TEST Operating instructions 22016401 Test function for communication testing. All characters received over the interface are shown in the display. Simple character strings can be sent, if desired. 06/09 25 Settings in the master mode ID7sx-Sys 4 I/O Parameters of the I/O module. Some parameters are not editable (dependent on the program). At ID7sx this module is mapped to the 8 I/O module. SWITCH ON/OFF Switches the function of this driver on or off. TEST Test function for testing the 4 I/O module The display shows the signal over inputs 1–4. Outputs 1–4 can be switched on or off using keys 1–4. Important Please ensure that no system functions are activated inadvertently! RELAY BOX 8 At ID7sx this module is mapped to the 8 I/O module. SWITCH ON/OFF Switches the function of this driver on or off. I/O TEST Tests function and state of inputs/outputs of 1 or 2 connected relay boxes 8-690 When an input or output is set (high), its number is shown in the display. When an input or output is not set (low), – is shown in the display. Setting outputs Switch outputs using keys 1 to 8 of the numeric keypad; . Setting inputs Inputs can be set by connecting a voltage supply (+24 V, current limited to 50 mA), for example. Comment The relay box 8-690 corresponds with the BIU Binary Interface Unit. For additional information, see the operating instructions and installation information for the 505918A Binary Interface Unit. 8 I/O Parameters of the I/O module. Some parameters are not editable (dependent on the program) SWITCH ON/OFF Switches the function of this driver on or off. TEST Test function for testing the 8 I/O module The display shows the signal over inputs 1–8. Outputs 1–8 can be switched on or off using keys 1–8. Important Please ensure that no system functions are activated inadvertently! PROFIBUS-DP Configuring Profibus-DP-ID7sx SWITCH ON/OFF Switches the function of this driver on or off. NODE ADDRESS Selects the desired node address from a range of 001 to 126. OPERATING MODE Possible settings: 4 words 8 words TEST Test function for testing the Profibus I/O values 26 Operating instructions 22016401 06/09 What to do if....? ID7sx-Sys 6 What to do if....? Error / Message Possible causes Rectification Display dark • No supply voltage ➜ Check power supply unit • Incorrect wiring ➜ Carry out wiring according to control drawing • Restless installation location ➜ Adjust vibration adapter • Draft ➜ Block draft • Interference between load plate and/or materials being weighed and environment ➜ Rectify interference • Power supply interference ➜ Check power supply • Incorrect zeroing of weighing platform ➜ Unload weighing platform, repeat zeroing and weighing • Incorrect tare value ➜ Delete tare or enter correct tarevalue • Interference between load plate and/or materials being weighed and environment ➜ Rectify interference • Weighing platform tilted ➜ Level out weighing platform • Incorrect weighing platform selected ➜ Select correct weighing platform IDENTCODE = • Test cycle started ➜ Complete test by pressing the ZERO-SET key ----------- • Load plate not in place ➜ Put load plate in place • Pre-load not in place ➜ Load pre-load • Weighing range dropped below ➜ Set to zero • Weighing range exceeded ➜ Unload weighing platform • Weighing platform locked ➜ Release lock • Error in weighing platform ➜ Test weighing platforms Weight display unstable Incorrect weight display SCALE ERROR ➜ If message appears again: Inform METTLER TOLEDO Customer Service SCALE OVERLOAD • Weighing range exceeded ➜ Unload weighing platform ➜ Release lock TOTAL IS NEGATIVE • Total weight is negative ➜ Unload weighing platform and set to zero ERROR TARE SET • Taring not possible, as total weight is negative ➜ Unload weighing platform and set to zero, repeat taring Operating instructions 22016401 06/09 27 What to do if....? ID7sx-Sys Error / Message Possible causes Rectification ERROR ZERO SETTING • Zero-set range exceeded ➜ Unload weighing platform and set to zero SCALE IN MOTION • Weight value does not remain constant ➜ Wait until weighing platform shows weight value which remains constant • Restless environment ➜ Ensure low-vibration environment ➜ Check setting of vibration adapter ➜ If message appears again: Inform METTLER TOLEDO Customer Service SCALE NOT ZERO • Zero point has shifted ➜ Set to zero PRINTER OFFLINE • Printer (GA46) switched off ➜ Switch on printer PRINTER NO PAPER • No paper in printer (GA46) ➜ Insert paper PRINTER ERROR • General printer error ➜ Inform METTLER TOLEDO Customer Service RAM CLEARED • New software in ID7sx-Sys, all data reset to factory setting NO ALIBI MEMORY !! • No alibi memory found ➜ Inform METTLER TOLEDO Customer Service ALIBI ERROR • Error in alibi memory ➜ Inform METTLER TOLEDO Customer Service NO SCALE FOUND • Weighing platform cable not connected properly ➜ Connect the weighing platform cable according to the control drawing • Load-cell cable not connected properly ➜ Inform METTLER TOLEDO Customer Service • Not all scales connected ➜ Connect all weighing platforms • Error in weighing cell ➜ Repeat test ERROR SCALE NUMBER – ➜ If message appears again: Inform METTLER TOLEDO Customer Service PERMISSION DENIED DATABASE INIT ERROR 28 • Two or more connected weighing platforms have identical scale number ➜ Inform METTLER TOLEDO Customer Service • Incorrect personal code ➜ Enter correct personal code • Incorrect information in FTP SECURITY or FTP FILE ➜ Enter permissible values for username, password, drive, directory and file name • Database could not be initialised ➜ Inform METTLER TOLEDO Customer Service Operating instructions 22016401 06/09 Technical data and accessories ID7sx-Sys 7 Technical data and accessories 7.1 Technical data Terminal Display • Backlit LC display, with graphics capabilities, 64 240 pixels, display field 39 x 132 mm • Cover of scratch-resistant, hardened, antireflection glass Keypad • Tactile-touch membrane keypad with acoustic acknowledgement • Scratch-resistant marking, 3-color • 4 keys A to D for identification data, 6 function keys with function change and info key, 4 scale function keys, numerical keypad • Alphanumeric input possible with function keys Housing • All nickel chromium steel DIN X5 CrNi 1810 • Weight: net 3.2 kg, without cables Type of protection • II 2G EEx ib IIC T4 –10 °C ... +40 °C • II 2D IP65 T55 °C Protection type (IEC 529) • Dust and water-tight as per IP65/68 Pollution degree 2 Installation category II Power supply connectioni • via PSU/ID..-Ex power supply unit (in the safe area) Ambient temperature • operation: –10 °C – +40 °C 0 – +40 °C • storage –25 °C – +60 °C • via PSUx/.. (in the hazardous area) for weighing platforms of certification class III for weighing platforms of certification class II Relative humididy 20 – 80 %, non condensing Weighing platform connection • 1 IDNet connection standard for METTLER TOLEDO weighing platforms of the DN...x, PUA..x, PTA...x, PBA430x series, Point Ex system solution and analog weighing platforms with Point Ex • In the configuration with the PSU power supply unit 2 additional IDNet connections (IDNet-ID7sx) are possible Serial interface connection Operating instructions 22016401 • 1 CL20mA connection standard • In the configuration with the PSU power supply unit max. 2 additional serial interface connections (CL20mA-ID7sx or RS232-ID7sx) possible, see guide for installers and control drawing ME-22006478 06/09 29 Technical data and accessories ID7sx-Sys Terminal Digital inputs/outputs 8 I/O-ID7sx module as an option • 8 digital inputs / 8 digital outputs, galvanically separated, passive • Signal level input logically 0 = not supplied with current < 0.3 mA logically 1 = supplied with current > 4 mA • Intrinsically safe connection values see PSU guide for installers and control drawing ME-22006478 Storage of certificationrelevant weighing data Alibi-Memory-ID7sx module as an option • Paperless archiving of certification-relevant weighing data • Capacity: approx. 700000 data records with net weight, tare weight, date and time • Convenient search function • Ring data buffer which overwrites the oldest data record when the memory capacity is exceeded Profibus-DP-ID7sx Housing Aluminium, DIN locking foot Dimensions 42 mm x 106 mm x 115 mm (W x H x D) Weight 2,400 g Protection type IP20 Supply 24 V DC +/– 20 % Current consumption 100 mA (at 24 V DC) CPU core 80C52, 32 K RAM, 128 K flash Displays 2 status LEDs UART interface RS232 UART buffer max. 15 KB Temperature range 0 – 50 °C Max. humidity 90 %, non-condensing Profibus DP connection, 9-pin Sub-D Electrical isolation DP interface and 24 V DC Baud rate up to 12 Mbit/s Node address adjustable to between 0 and 126 in the master mode Factory setting: 126 Data width 2/4 IN and 2/4 OUT words, consistent for 2 words at operating mode 16-bit integer or for 4 words at operating mode 32-bit floating point Status indication 2 LEDs 30 Operating instructions 22016401 06/09 Technical data and accessories ID7sx-Sys 7.2 Accessories Weighing platform connections Order No. IDNet-ID7sx 22 008 443 • Connection for a weighing platform • Max. of 2 additional connections possible Point Ex-ID7sx • Connection for an analog weighing platform 22 008 443 • Max. of 2 additional connections possible Active CL/IDNet-ID7sx • Connection for a weighing platform 22 008 443 • Connection of a second ID7sx for use as a second display Serial data interfaces Order No. CL20mA-ID7sx CL 20 mA interface, for installation in ID7sx 22 008 444 RS232-ID7sx RS232 interface, for installation in ID7sx 22 008 445 Digital inputs/outputs 8 I/O-ID7sx Order No. 8 digital inputs, 8 digital outputs Network connection Profibus-DP-ID7sx Order No. Field bus module: Connection via PSU/ID..Ex Alibi Memory module Alibi-Memory-ID7sx 22 008 446 22 008 649 Order No. • Paperless archiving of certification-relevant weighing data 22 008 447 • Fail-safe storage of configuration data Barcode reader Barcode kit ID7sx Operating instructions 22016401 Order No. barcode scanner (II2G EEx ib IIC T4; II2D T 70°C) complete with RS232-ID7sx and Viper-Ex (SW) slotcard 06/09 22 008 640 31 Technical data and accessories ID7sx-Sys Other accessories Order No. ID7sx installation set for cabinet installation 22 008 439 Wall bracket Completely rust-proof 00 504 130 Floor stand Completely rust-proof 00 504 132 Stand socket Completely rust-proof 00 503 701 Bracket stand Completely rust-proof 00 504 128 32 Operating instructions 22016401 06/09 Index ID7sx-Sys 8 Index A Accessories...................31 Additional functions .......12 Alibi memory...........14, 25 Alphanumeric identification ..............19 Applications ....................5 Autozero ...................9, 23 B Basic functions................9 Big Weight Display ..........6 C Cleaning.........................8 Commissioning ...............8 D Date.............................21 Digital inputs/ outputs................30, 31 Display.....................6, 29 Display update ..............24 Documentation................5 E Entries..........................19 Error messages .............27 F Function keys......6, 12, 29 H Housing .......................29 I I/O test .........................26 ID code ........................12 Interface 4 I/O......................26 8 I/O................26, 31 CL20mA-ID7sx .......31 Interface connections .........25, 29 Introduction.....................5 K Keypad.....................7, 29 M Master mode ................ 17 Master mode block INTERFACE ............ 25 SCALE ................... 22 TERMINAL.............. 20 Multi-scale mode .......... 10 P Personal code .............. 21 Profibus-DP 25, 26, 30, 31 R Recall information ......... 13 Relay box 8 ................. 26 Reset scale .................. 23 Reset terminal .............. 20 Restart......................... 24 S Safety precautions........... 4 Scale modes ................ 21 Serial (RS232, CL, RS422/485) ............. 25 Set zero ......................... 9 Stability detector ........... 23 Switch over weighing platform.................... 10 T Tare .............................. 9 Technical data .............. 29 Terminal ...................... 29 Test weighing platform .. 12 Time............................ 21 V Vibration adapter .......... 23 W Weighing ..................... 10 Weighing platform connections ........ 29, 31 Weighing process adapter..................... 23 What to do if....?........... 27 L Language .....................20 Operating instructions 22016401 06/09 33 Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use according to these instructions and regular calibration and maintenance by our factory-trained service team ensure dependable and accurate operation, protecting your investment. Contact us about a ServiceXXL agreement tailored to your needs and budget. We invite you to register your product at www.mt.com/productregistration so we can contact you about enhancements, updates and important notifications concerning your product. *22016401* 22016401 Subject to technical changes © Mettler-Toledo (Albstadt) GmbH 06/09 Mettler-Toledo (Albstadt) GmbH D-72458 Albstadt Tel. ++49-7431-14 0, Fax ++49-7431-14 232 Internet: http://www.mt.com Printed in Germany 22016401
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project