CAT_ChromatographyConsumablesAndSuppliesCatalog pdf

CAT_ChromatographyConsumablesAndSuppliesCatalog pdf
www.perkinelmer.com/supplies
Chromatography
Consumables and Supplies
Genuine PerkinElmer Products — Genuine Value
VOLUME 4 2010 – 2011
PerkinElmer—The Clear Choice in Chromatography
NEW! Flexar FX-15 UHPLC System
SWAFER
Nitrogen Generators!
Micro-Channel
Wafer Technology
The newest membrane
technology for safe
production of pure
nitrogen gas.
See page 30 for details.
FlowMark™ Electronic
Flowmeter!
Compact handheld meter with data
output via USB port.
See page 37 for details.
SAVE
See page 29
for details.
Thermal Desorber Tubes
SVI™ Soil Vapor
Intrusion™ Tubes
See page 53 for details.
Volume discounts available on
Crimp Top Headspace Vials
with write on patch and fill indicator lines
See page 48 for details.
Order online at www.perkinelmer.com/supplies
ordering information
New Investments – Local Support – Proven Quality!
For over 50 years, PerkinElmer has helped our global laboratory partners meet their most demanding application
measurement challenges. Our experience in Chromatography, Spectroscopy and Material Characterization gives us
a unique advantage in providing holistic and comprehensive solutions for laboratories in universities and key market
segments like Environmental, Energy, and Food & Product Safety.
When you order our precision-designed, genuine PerkinElmer consumables and accessories, you can enjoy the
peace of mind, ease of ordering, and best-in-class service. You’ll get the results you need – accurately and on time.
PerkinElmer selects only the highest quality products for our consumables portfolio and invests heavily to test and
validate the quality of our products.
Telephone
Facsimile
Africa & East/Central Europe
French Africa ............................33 1 64 86 28 28
Egypt & English Africa ..................202 22905306
Bulgaria ......................................359 2 952 0301
Croatia ........................................385 1 2001 767
Poland ......................................48 22 310 88 00
Romania ....................................40 21 316 2877
Latvia ..........................................371 6755 1894
Lithuania ......................................370 5 2638748
Hungary ........................................36 1 251 1116
Czech Republic ........................420 241 430 534
Slovakia ....................................421 48 4155008
Telephone
Facsimile
Cyprus ......................................357 22 33 82 34
Russian Federation ....................7 495 935 8888
Turkey - Ankara ........................90 312 472 6363
Turkey - Istanbul ......................90 212 212 5566
Israel ..........................................972-3-9777000
Malta ..........................................356 21 344 345
Portugal ..................................351 21 782 60 30
Greece - Hellas..........................30 2310 322525
Greece - Athens ......................30 210 779 5980
Iceland ..........................................354 568 8533
357 22 33 82 32
7 495 564 8787
90 312 472 6313
90 212 212 2829
972-3-9777001
356 21 343 952
351 21 782 60 39
30 2310 321912
30 21 771 6932
354 568 0304
Export Territories
33 1 69 07 69 54
202 22905307
359 2 952 3784
385 1 2001 724
48 22 310 88 01
40 21 316 2876
371 6755 1976
370 5 2638749
36 1 251 1461
420 241 430 535
421 48 2301628
Middle East
Americas
Argentina ..................................54 11 4554 4004
Brazil ........................................55 11 3868 6200
Canada ....................................905-851-4585 or
800-561-4646
Chile ............................................56 2 784 7500
Mexico......................................52 55 5337 0700
Puerto Rico....................................787 783 3067
United States............................203-925-4600 or
800 762-4000
Central America........................52 55 5337 0700
54 11 4554 2807
55 11 3868 6210
905-851-1814
56 2 269 8070
52 55 559 36223
787 793 7198
203-944-4904
52 55 559 36223
Asia
Australia ................................61-3-9212-8500 or
1-800 033 391
China - Shanghai ......................86-21-38769510
China - Beijing ..........................86-10-58208166
China - Chengdu ................86-28-8678 2887 or
86-28-8678 2662 or
86-28-86783530
China - Wuhan ....................86-27-8732-2732 or
86-27-8732-2756 or
86-27-8732- 2826
China - Shenyang....................86-24-2256-6158
China - Guangzhou ................86-20-8363 3179
Hong Kong..................................852-2620-1881
India - Mumbai ..........................022- 6760 1700
Indonesia ............................62-21-55960245-48
Japan - Yokahama ....................81-45-339-5861
Japan - Osaka ..........................81-6-6386-6004
Japan - Kyushu ........................81-92-473-7001
Japan - Tokyo............................81-3-3866-2647
Korea ............................................82 2 868 5350
Malaysia ...................................... 603-79491118
New Zealand ..........................64-21-751-007 or
0800 776 767
Philippines................................(+63-2) 637 0180
Singapore ......................................65-67799555
Taiwan - Taipei ..........................886-2-27647199
Taiwan - Kaohsiung ....................886-7-5521030
Thailand..........................................662-3197901
Vietnam - Hanoi ..........................(84) 4 7472259
Vietnam - Ho Chi Minh City ........(84) 8 8394155
2
61-3-9212-8595
86-21-50791316
86-10-58208155
86-28-8678 2522
86-27-8732-2685
86-24-2256-6153
86-20-8363 3579
852-2620-1238
022 - 6760 1791
62-21-55960167
81-45-339-5871
81-6-6386-7009
81-92-473-8353
81-3-3866-2652
82 2 868 4343
603-79491119
64-9-966-2955 or
0800 776 000
(+63-2) 910 1168
65-68726595
886-2-27647209
886-7-05543402
662-3197900
(84) 4 7472260
Bahrain ......................................971 4 883 0233
Kingdom of Saudi Arabia - Central
....................................................966 1 4793000
Kingdom of Saudi Arabia - East
....................................................966 3 8475299
Kingdom of Saudi Arabia - West
....................................................966 2 6720888
Kuwait ........................................965 246 10 480
Oman ......................................968 248 14752 or
99269420
Pakistan ..................................92 21 5345581 or
5340747 or
52417934 or
53460578
Qatar ..............................................974 4654563
Republic of South Africa ............27 11 794 4430
United Arab Emirates ................971 4 883 0233
Yemen............................................967 234 5073
971 4 883 0133
966 1 4771374
966 3 8475296
966 2 6725664
965 246 10 488/9
968 248 13924
92 21 5345582
974 4652256
27 11 794 2160
971 4 883 0133
967 234 0504
Western Europe
Austria ..........................................0800 111 933
Belgium ............................................0800 40858
Denmark ..........................................80 88 42 36
Estonia..........................................372 7 383 330
Finland ....................................358 (0)2 267 8111
France............................................0805 111 333
Germany....................................0800 1 81 00 32
Italy..............................................800 906 642 or
39 039 2383-1
Luxembourg......................................0800 26588
Netherlands ..................................0800 0234490
Norway ..............................................800 18 854
Republic of Ireland ........................1800 932 886
Spain ..........................................918 061 200 or
800 099 164
Sweden..........................................0200 887 520
Switzerland ....................................0800 000 015
United Kingdom ..........................0800-89 60 46
0800 111 934
0800 40859
80 88 42 37
372 7 383 360
358 (0)2 267 8599
0805 111 334
0800 0 00 66 79
39 039 2383 490
0800 26589
0800 0234491
800 18 855
1800 932 884
918 040 414 or
800 099 165
0200 887 521
0800 000 016
0800-89 17 14
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Table of Contents
Liquid Chromatography
Order Online
Place your order online at:
www.perkinelmer.com/supplies
NEW Flexar Series UHPLC System . . . . . . . . . . . . . . . . 4–7
Online ordering is currently available in Australia, Austria, Belgium,
Canada, Denmark, Finland, France, Germany, Ireland, Italy, Luxemburg,
the Netherlands, Norway, Puerto Rico, Spain, Sweden, Switzerland,
the United Kingdom and the United States.
NEW Flexar Autosampler and Accessories . . . . . . . . 8–11
Order by Phone, Fax or E-mail
Cartridge Columns . . . . . . . . . . . . . . . . . . . . . . . . . . 16–21
Please contact your local PerkinElmer Customer
Care Representative. See local office listings to the
left. Or visit www.perkinelmer.com/lasoffices.
Sample Loops Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Order by Mail
HPLC Pump Accessories. . . . . . . . . . . . . . . . . . . . . . 24–26
Visit us online at www.perkinelmer.com/lasoffices
to obtain the correct address for mailing your
company Purchase Order.
Flow Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Conventional Columns . . . . . . . . . . . . . . . . . . . . . . . 12–15
Fingertight® Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Detector Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Return Goods Policy
Before returning any item to PerkinElmer, please
obtain a Return Authorization Number from a
customer service representative. Call your local
PerkinElmer office and please have the following
information ready:
22
Gas Chromatography
Clarus 600 GC and GC/MS . . . . . . . . . . . . . . . . . . . . 30–31
Our Order Number or your Purchase Order Number
■
The PerkinElmer part numbers of the
items that you wish to return
GC Organic Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . 32
■
Reason for return
Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33–35
28
Leak Detector and IR Temperature Gun. . . . . . . . . . . . . 36
Flowmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
32
Ferrules, Syringes and Liners. . . . . . . . . . . . . . . . . . 38–39
Technical Support
Vials, Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . 40–41
For technical assistance, please contact your local
PerkinElmer Customer Care Representative. See
local office listings to the left.
Elite Series Capillary Columns . . . . . . . . . . . . . . . . . 42–44
Check with your local PerkinElmer Customer Care center for
current pricing.
PerkinElmer and the PerkinElmer logo are registered trademarks of
PerkinElmer, Inc. All other product and company names mentioned
herein may be the trademarks or registered trademarks of their
respective owners.
PerkinElmer is not responsible for typographical or photographic errors
that may appear in this catalog. We reserve the right to make adjustments
or corrections due to changing market conditions, product discontinuations,
or typographical or photographic errors in advertisements or product
descriptions. Terms and conditions and item availability are subject to
change without notice.
16
Nitrogen Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
■
Our customer service representative will provide
you with a Return Authorization Number and the
return address. We cannot accept any returns
without a Return Authorization Number. Policy
may vary. Please contact your local PerkinElmer
representative for details.
6
table of contents
Ordering Information
Applications Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
38
Headspace/Traps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Headspace Vials and Caps . . . . . . . . . . . . . . . . . . . . 47–51
Packed Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
49
Thermal Desorption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Air Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56–57
For details on our terms and conditions,
including warranties, please visit:
www.perkinelmer.com/terms
Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
54
One Source Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Order online at www.perkinelmer.com/supplies
ORDER TODAY
3
Flexar UHPC
Power and Flexibility
in UHPLC
FX-15
ULTRA HIGH
PERFORMANCE LC
18,000 PSI
FX-10
ULTRA HIGH
PERFORMANCE LC
10,000 PSI
PERFORMANCE
LC
CONVENTIONAL LC
6,000 PSI
LC
CONVENTIONAL LC
MANUAL INJECTION
PRODUCTIVITY
New Flexar™ UHPLC
System from PerkinElmer
With Flexar UHPLC, you'll be able to transfer your existing methods to
achieve faster, more predictable results while reducing your solvent
consumption by up to 90%. The FX-15's patented, dual reciprocating,
18,000 psi pump offers the widest operating range with exceptional
compositional accuracy and retention time repeatability. The value and
performance of the FX-10 microbinary pump offers minimal disruption
in your method development phase and analytical approach so you
can easily port your existing methods. And with the powerfully easy
new Chromera® software, instrument control is taken to a whole new
level. Performance, flexibility and predictability — Flexar.
Flexar UHPLC Systems
Description
Part No.
Flexar FX-10 UHPLC Platform
Flexar FX-10 UHPLC Pump
Flexar FX-10 UHP Pump Master
"Flexar Bottle Manager, 3-channel Vacuum Degassing" tubing kit
NFLR0210
N2910640
N2910641
N2600581
Flexar UHPLC Systems
4
Benefits of Flexar UHPLC:
Description
Part No.
■
Improved separation efficiency
■
Up to 90% reduction in solvent consumption — saving you money
Flexar FX-15 UHPLC Platform
Flexar FX-15 UHPLC Pump
"Flexar Bottle Manager, 3-channel Vacuum Degassing" tubing kit
NFLR0215
N2910531
N2600581
■
Up to 10x productivity gains — helping you do more in less time
See page 2 for ordering information and a complete listing of PerkinElmer offices.
The Powerfully Easy CDS
One click and you’ll see: CDS doesn’t get any easier than Chromera. Combining intuitive ease of
use with powerful functionality and configurability, Chromera delivers the most streamlined way to
get from the analysis you need to the information your enterprise demands. It’s powerfully easy.
Information-rich Desktop offers instrument control at-a-glance
Chromatography Data System
Chromera® Chromatography
Data System
Features and Benefits:
Powerful
Easy
■
Instrument Control: NEW patented “Device Descriptors” control
instruments. No channels limitation, trackable instrument status
■
Shallow footprint GUI: Most functions only one or two clicks away,
using familiar Microsoft™ Outlook user interface
■
Designed for UHPLC: interactive graphical methods optimization
environment with immediate feedback; ability to overlay pressure
profile run after run. Extend runtime of chromatogram in real time
■
■
Graphics: Multichannel graphics for multiple signal channel
monitoring (including system status channels to get ‘the pulse
of the system’ real-time)
Simple and obvious method editor: a single-point access to
all instrument parameters, regardless of how complex the
instrument configuration; Convenient tools for point-and-click
method optimization
■
Intuitive Sequence Wizard: Create complex sample tables easily;
Convenient auto-fill and other editing functions; Decision Points
for real-time and post-processing data evaluation
■
Feedback: Instrument-at-a-glance status panel provides real-time
feedback of complete LC system
■
■
Batch Sequencing: all the functions for setting up and reviewing a
sequence and results are within a single environment
Peak Integration Wizard: Makes integration process easy and
straight forward
■
Report Wizard: allows creating numerous styles of reports and
printouts using the same tool
Order online at www.perkinelmer.com/supplies
ORDER TODAY
5
Flexar FX UHPLC
Flexar UHPLC Systems...
you don’t have to pay more to
achieve so much
FX-10
UHPLC System
FX-15
UHPLC System
FX-10: High Value UHPLC
6
■
Micro Binary 10,000 psi pump package
■
High efficiency FX UHPLC autosampler
■
Column oven for retention time reproducibility
and viscosity reduction
■
High speed FX UV/VIS detector (100 pt/sec) with
high efficiency 2.4μL flow cell
■
Straightforward method transfer to UHPLC
FX-15: Ultimate in UHPLC
■
Dual reciprocating 18,000 psi pump with exceptional
compositional accuracy, retention time reproducibility
and automatic piston wash
■
High efficiency FX UHPLC autosampler
■
Column oven for retention time reproducibility
and viscosity reduction
■
High speed FX UV/VIS detector (100 pt/sec)
with high efficiency 2.4μL flow cell
See page 2 for ordering information and a complete listing of PerkinElmer offices.
PerkinElmer syringe kits for high pressure applications are manufactured
for precise liquid delivery. All of these glass syringes come with precision
stainless steel plungers. They are used for sampling and flushing and are
available in a large variety of sizes. The 250 μL syringe comes standard
with both the Series 225 and Series 275 Autosamplers.
Interferene
Syringe
KitsCheck Standards
Description
Part No.
100 μL w/ 200 μL Buffer Tubing
250 μL w/ 500 μL Buffer Tubing
500 μL w/ 1,000 μL Buffer Tubing
1000 μL w/ 2,000 μL Buffer Tubing
2500 μL w/ 2,000 μL Buffer Tubing
N2936051
N2936052
N2936053
N2936054
N2936055
Interferene Check Standards
Syringes
Description
Part No.
Sample Needle w/ fittings
Air Guide Needle (62 mm)
Bio Compatible Sample Needle w/tubing Connector
Needle (80 mm)
N2936009
N2936000
N2936010
N2936342
Interferene
FX-15
UHPLC
Check
PumpStandards
Accessories
Description
Part No.
Replacement 0.5 μm filter frits for FX-15 (4-pack)
High pressure FX-15 piston seal kit
Piston wash bottle kit
N2911224
N2911221
N2601616
FX-10
Interferene
& FX-15
Check
UHPLC
Standards
System Accessories
Description
Part No.
0.005” ID PEEK tubing (blk), 50 cm
0.004” ID PEEK tubing (red), 50 cm
Connector tubing, Flexar iso/binary/quaternary pump to autosampler, SS
Connector tubing, dual mixer connection (≤250 μL), SS
Connector tubing, dual mixer connection (³350 μL), SS
Connector tubing, FX-10 pump A (upper) to T-mixer, SS
Connector tubing, FX-10 pump B (lower) to T-mixer, SS
Connector tubing, FX-10 purge valve to filter/scavenger, SS
Connector tubing, FX-10 injector to column, SS
Connector tubing, FX-10 pump A (upper) to dual mixers, SS
Connector tubing, FX-10 pump B (lower) to dual mixers, SS
Connector tubing, FX-15 pump to in-line mixer, SS
Connector tubing, FX-15 pump to dual mixers, SS
Connector tubing, FX-15 injector to column, std, SS
Connector tubing, FX-15 injector to column, 33 cm, SS
3cmm scavenger cartridge holder
Spheri5 scavenger columns (5-pack)
N2916200
N2916059
N2916210
N2916216
N2916217
N2916213
N2916214
N2916212
N2916215
N2916218
N2916219
N2916222
N2916224
N2916223
N2916201
02580178
02580202
Microsyringes (For Manual Injection)
Syringes are used for accurate and precise liquid delivery. Each syringe
is hand-fitted to assure maximum accuracy. Our syringes are composed
of glass barrels and precision stainless steel needles. The needle
features a blunt tip, required for use with a Rheodyne injector.
Flexar UHPLC
System
Accessories
High Pressure Static Mixers
Static Mixers are important in facilitating complete mobile phase
blending, resulting in improved retention performance. These mixers
should be used as part of Series 275, FX10, or FX15 LC systems,
where high pressure blending is required. Mixers incorporate a highly
efficient cross-flow shearing mechanism which produces vortex sheer
mixing over a wide range of volumes. They are now offered in 18,000
psi pressure max flavor.
Flexar Accessories
Syringes and Kits
A good first choice selection is a volume of about half the flow rate
volume. For example, when pumping at a 0.5 mL/min flow rate, a
350 μL mixer provides good mixing with very good baseline stability.
Interferene
High
Pressure
Check
Analytical
Standards
Static Mixers
Description
Part No.
50 μL In-Line High Pressure Mixer Assembly, SS
150 μL In-Line High Pressure Mixer Assembly, SS
250 μL In-Line High Pressure Mixer Assembly, SS
350 μL In-Line High Pressure Mixer Assembly, SS
500 μL In-Line High Pressure Mixer Assembly, SS
150 μL High Pressure Binary High Pressure Mixing-T, SS
10 μL Binary Mixing-T, SS
Binary high pressure T-Mixer, SS, 50 uL
Binary high pressure T-Mixer, SS, 350 uL
Binary high pressure T-Mixer, SS, 500 uL
T-connector, SS
N2911200
N2911201
N2911202
N2911205
N2911203
N2911206
N2911170
N2911212
N2911210
N2911211
N2911127
Solvent and Sample Filtration
Syringe filters are important for high pressure applications of effectively
filter samples to prevent premature column performance loss and
possible flow restriction of the narrow tubing that is typically required
for high pressure LC applications.
Interferene
Syringe
Filters
Check Standards
Description
PVDR 13 mm Filter (pkg. 100)
Nylon 17 mm Filter (pkg. 100)
Nylon 17 mm Filter (pkg. 100)
Nylon 30 mm Filter (pkg. 100)
Nylon 30 mm Filter (pkg. 100)
PTFE 17 mm Filter (pkg. 100)
PTFE 30 mm Filter (pkg. 100)
PTFE 30 mm Filter (pkg. 100)
Pore Size
Part No.
0.45 μm
0.45 μm
0.20 μm
0.45 μm
0.20 μm
0.20 μm
0.45 μm
0.20 μm
02542783
02542880
02542881
02542882
02542883
02542884
02542885
02542886
Interferene Check
Microsyringes
(ForStandards
Manual Injection)
Description
Part No.
10 μL Syringe
25 μL Syringe
50 μL Syringe
100 μL Syringe
Rheodyne 22-gauge Blunt Needle with Luer Hub
09904937
09904823
09904941
09904822
09904943
Interferene Syringes
Disposable
Check Standards
Description
Part No.
Disposable Syringes, Luer-Lock Tips, 1 mL
Disposable Syringes, Luer-Lock Tips, 3 mL
02542890
02542891
Order online at www.perkinelmer.com/supplies
ORDER TODAY
7
Flexar Autosamplers and
Inject with Greater precision
Best-in-class cycle time. Wide injection volume range. Excellent
injection reproducibility. Precisely what you need to increase
your sample throughput and efficiency.
Flexar or Series 225/275 Autosampler Trays
Description
Part No.
25-Position 6 mL Vial Sample Tray
N2936045
80-Position 2 mL Vial plus (5) 6 mL Vial Tray (for derivatization)
N2936046
80-Position 2 mL Vial Tray with Dilution Tray
N2930676
96-well Microtiter
N9302562
96-well ‘Deep-well’ Microtiter
N9302560
96-well 7 mm Pre-slit Silicone Plate mat/Seal
N9302555
96-well ‘Shallow’ Microtiter Plate Adaptor (supports dual microtiter plates) N2936048
96-well ‘Deep’ Microtiter Plate Adaptor (supports dual microtiter plates) N2936049
100-Position 2 mL Vial Sample Tray
N2936042
(200) 0.2 mL Microvial plus (5) 2 mL Vial Tray
N2936043
■
Injects sample volumes as little as 1 μL at pressures up to
18,000 psi with the FX UHPLC Autosampler
■
Loads sample in only 8 seconds (in partial fill mode)
■
Three injection modes: full loop, partial fill and μL-pickup
with no sample waste
■
Peltier cooling/heating mode option for operation at 4 °C to
40 °C. Will reach 4 °C ± 2 °C, achievable even at
ambient temperatures up to 25 °C.
All Flexar autosamplers can be upgraded in the field for Peltier
cooling and heating. All Flexar autosamplers include:
■
100sample tray
■
100 2mL vials
■
100 2mL screw top cap with cross slit vial septum
■
Tubing to connect to waste reservoir
■
All cables required for connection to a TotalChrom or Chromera
Operating Environment
■
I/O cable (Pump Start / ReadyIn)
■
Service Manager SW CD
■
Userʼs Manual
■
Nuts and ferrules
■
All fuses for 120–240 V
Flexar Autosamplers and Upgrade Kits
Flexar LC Autosampler
Description
Part No.
High throughput autosampler with exceptionally low carryover. Operates up to 6100 psi (420 bar). Provides flexible injection modes: full-loop, partial-fill and μL-Pickup
(no sample waste). Peltier cooling and heating options available as field upgrades. Comes standard with 100 μL loop and 250 μL sample flush syringe.
N2930660
Flexar Peltier LC Autosampler
Description
High throughput autosampler with exceptionally low carryover. Operates up to 6100 psi (420 bar). Provides flexible injection modes: full-loop, partial-fill and
μL-Pickup (no sample waste). Built-in Peltier cooling comes standard. Peltier heating option available as field upgrade. Comes standard with 100 μL loop and
250 μL sample flush syringe.
Part No.
N2930661
Flexar FX UHPLC Autosampler
Description
High throughput UHPLC autosampler with exceptionally low carryover. Operates up to 18,000 psi (1,241 bar). Provides flexible injection modes: full-loop,
partial-fill and μL-Pickup (no sample waste). Built-in Peltier cooling comes standard. Peltier heating option available as field upgrade. Comes standard
with 10 μL loop and 250 μL sample flush syringe.
Part No.
N2930664
Field Upgrade Peltier Kits
Description
Flexar and Series 225 Upgrade Kit (from standard to Peltier Cooling option)
Flexar and Series 225 Upgrade Kit (from standard to Peltier Cooling and Heating option)
Flexar and Series 225 Upgrade Kit (from Peltier Cooling to Peltier Cooling and Heating option)
8
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Part No.
N2930672
N2930673
N2930669
Accessories
Vials, Caps and Septa Kits
from PerkinElmer
PerkinElmer Supplies – Tested and Approved
We have expanded our product selection to include additional vial types,
new version caps and mating septa in a kit format for easier customer
ordering. This reference guide contains both current and new product
information. Tested to mmet your application requirements andguaranteed
for fit and compatibility.
LC Vials, Caps and Septa
PerkinElmer offers a variety of vials, caps and septa to fulfill your application
needs. Our screw thread vial caps use the revolutionary Inter-Seal®. Using a
process that bonds silicone/PTFE and other elastomeric compounds directly
into thermoplastic closures eliminates liner fallout, while still providing the
excellent resealability and multiple injection capability. No adhesives are
used in many markets including: environmental, diagnostic packaging,
pharmaceutical packaging, cosmetic and food packaging.
2.0 mL Vials, Caps and Septa
Vials*
Description
2 mL 11 mm Clear Glass Crimp Vials
2 mL 11 mm Amber Glass Crimp Vials
2 mL 11 mm Clear Snap Top Vial
2 mL 11 mm Clear Snap Wide Opening Vials
with Write-On Patch and Fill Lines
2 mL 11 mm Amber Snap Wide Opening Vials
with Write-On Patch and Fill Lines
2 mL 10 mm Clear Glass Screw Top Vials
with Write-On Label and Fill Lines
2 mL 10 mm Amber Glass Screw Top Vials
with Write-On Label and Fill Lines
2 mL 10 mm Screw Top Vial Caps, Black
Polypropylene with PTFE/Slit White Silicone
2 mL 9 mm Clear Screw Top Vial
2 mL 9 mm Amber Glass Screw Top Vial
Pkg
100
100
100
100
Part No.
N9301385
N9302680
N9303418
N9306207
100
N9306208
100
N9306053
100
N9306057
100
N9306052
Caps/Septa:
100
100
N9306201
N9306220
Description
Pkg
Part No.
8 mm Silver Aluminum Crimp Cap PTFE/Rubber
PTFE/Pre-Slit White Silicone Polyethylene Press-On
Cross-Slit Cap for 8 mm Vials
1000
1000
03300806
N9302141
Pkg
1000
Part No.
04978532
Description
Pkg
Part No.
1000
N9307023
Glass Microvials, Tapered, 0.2 mL, 8 mm o.d. Top*
500
N9302136
100
N9306052
100
N9306205
Description
Pkg
Part No.
25
N9307027
100
N9302684
12 x 32 Glass Vial Support Sleeve for 2 mL
8 mm Micro Vials (N9302136)
100
N9302685
100
N9302686
Description
Pkg
Part No.
500
N9306080
N9306015
Polyethylene Includes 300 μL Tapered Vial, Blue
Polypropylene Cap with Bonded Silicone/PTFE Septa
Caps/Septa*
Description
11 mm Snap Cap Polyethylene
Cross-cut Slit (no Septum)
11 mm Snap Cap Polyethylene
Single Slit (no Septum)
10 mm PTFE/Silicone
Single Slit Screw Cap Black
10 mm PTFE/Silicone
No Slit Screw Cap Black
11 mm Crimp Green Aluminum Cap
w/Teflon® Rubber Septa
11 mm Crimp Red Aluminum Cap
w/Teflon® Rubber Septa
11 mm Crimp Blue Aluminum Cap
w/Teflon® Rubber Septa
11 mm Crimp Silver Aluminum Cap
w/Teflon® Rubber Septa
100
* Also see Convenience Kits for additional vials and caps sold separately.
0.2 mL Micro Vials, Caps and Septa
Crimp Top Vials:
Autosampler Vial Sleeve:
Micro Vial Kit:
* To be used with Glass Vial Support Sleeve (N9307227).
Order online at www.perkinelmer.com/supplies
ORDER TODAY
9
Flexar Autosampler
Vials, Caps and
Septa Kits from
PerkinElmer
Autosampler Vial Glass Inserts
Vial Glass Inserts:
Kits for your LC Autosampler
Description
Autosampler Vial Starter Kits
Complete and convenient starter kits for your volatile and standard applications.
Each kit contains everything you need to run your LC instruments under two
convenient part numbers. Each kit contains syringes, vials, caps and a vial rack.
Description
Pkg.
LC Screw top Starter Kit:
30 mL Pump Priming Syringes
Racks for 50 12 mm Vials
Polypropylene Screw Caps
PTFE/Silicone (Pkg/100)
2 mL 10 mm Screw Top Vials
w/Label and Fill Lines (Pkg/100)
2 mL 10 mm Screw Top Amber Vials
w/Label and Fill Lines (Pkg/100)
25 μL Blunt Syringes
1
⁄16 Union Tubes
Nut and Ferrules (Pkg/6)
LC Crimp top Starter Kit:
Crimper Tool (Manual)
Racks for 50 12 mm Vials
2 mL 11 mm Crimp Top Vials (Pkg/100)
2 mL 11 mm Crimp Top Amber Vials (Pkg/100)
25 μL Blunt Syringes
11 mm De-capper Tool (Manual)
11 mm Silver Crimp Top Caps w/Septa (Pkg/100)
Part No.
3
2
4
N2930366
09904849
N9301303
N9306052
2
N9306053
2
N9306057
2
2
1
09904823
09903289
02540274
N2930365
00090699
N9301303
N9301385
N9302680
09904823
N9301390
N9306015
1
2
3
1
1
1
4
Syringe Filters
N9300703
N9300704
N9306057
N9306053
N9303418
N9306231
N9306220
N9306201
N9300705
N9300706
N9302680
N9301385
N9302945
6 mL Vials and Caps
Description
Pkg.
Part No.
6 mL Glass Large-Volume Vials
with 20 mm o.d. Top
Polyethylene Press-On Slit Caps/Septa
or 20 mm o.d. Top Vials
125
N9302134
25
N2936083
100
100
100
100
100
100
100
100
0.45 μm
0.45 μm
0.20 μm
0.45 μm
0.20 μm
0.20 μm
0.45 μm
0.45 μm
02542783
02542880
02542881
02542882
02542883
02542884
02542885
02542886
Description
Pkg.
Part No.
Polyethlene Micro Vial Kit – Pkg/500
Includes:
300 L Tapered Screw Top Vials (Pkg/500)
Blue Polypropylene 9 mm Caps w/Bonded
Silicone/PTFE Septa (Pkg/500)
1.5 mL Polypropylene Screw Top
Amber Vial With Fill Lines, Teflon®/
Silicone Septa and Cap With Single Slit
1.5 mL Polypropylene Screw Top
Clear Vial With Fill Lines,Teflon®/
Silicone Septa and Cap With Single Slit
500
N9306080
100
N9301735
100
N9301736
Additional pore sizes are available on the PerkinElmer website.
10
Part No.
Micro Vial Kit and Polypropylene Vial/Cap Kits
Syringe filters are important for high-pressure applications to effectively filter
samples to prevent prem ature columnperformance loss and possible flow
restriction of the narrow tubing.
Description
Pkg.
Pore Size
Part No.
PVDR 13 mm Filter
Nylon 17 mm Filter
Nylon 17 mm Filter
Nylon 30 mm Filter
Nylon 30 mm Filter
PTFE 17 mm Filter
PTFE 30 mm Filter
PTFE 30 mm Filter
Pkg.
6 mm x 29 mm Clear Glass Insert,
100
Rimless Pulled Point with Bottom Spring,
250 μL Usable Volume
6 mm x 31 mm Clear Glass Flat Bottom Insert,
100
400 μL Usable Volume
Use with:
10 mm 2 mL Amber Screw Top Vial w/White “P” Icon w/Patch
10 mm 2 mL Clear Screw Top Vial w/White “P” Icon w/Patch
11 mm Clear Large Opening Snap Ring Vial w/Black “P” Icon
11 mm Clear Large Opening Crimp Vial w/Black “P” Icon
9 mm 2 mL Amber Screw Top Vial w/Black “P” Icon
9 mm 2 mL Clear Screw Top Vial w/Black “P” Icon
5 mm x 29 mm Clear Glass Insert,
100
Rimless Pulled Point with Bottom Spring,
150 μL Usable Volume
5 mm x 31 mm Clear Glass Flat Bottom Insert,
100
200 μL Usable Volume
Use with:
11 mm Standard Amber Crimp Vial w/Black “P” Icon
11 mm Standard Clear Crimp Vial w/Black “P” Icon
8 mm 2 mL Clear Screw Top Vial w/Black “P” Icon
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Easy-to-order Convenience Kits (Vials and Caps/Septa also Sold Separately)
Description
Pkg.
Part No.
™
100
N9300707
™
100
N9300708
9 mm Pre-Slit PTFE/Silicone Screw Cap Convenience Kit – Pkg/100:
9 mm Pre-Slit PTFE/Silicone Screw Cap Assembly (Pkg/100)
9 mm 2 mL Clear Screw Vial Kit (Pkg/100)
1
1
N9300701
N9306203
N9306201
9 mm Red Rubber Screw Cap Convenience Kit – Pkg/100:
9 mm Red Rubber/Screw Cap Assembly (Pkg/100)
9 mm Clear 2 mL Vial Kit (Pkg/100)
1
1
N9300699
N9306200
N9306201
9 mm PTFE/Silicone Screw Cap Convenience Kit – Pkg/100:
9 mm PTFE/Silicone Screw Cap Assembly (Pkg/100)
9 mm Clear 2 mL Vial Kit (Pkg/100)
1
1
N9300700
N9306202
N9306201
11 mm Pre-Slit PTFE/Silicone Snap Convenience Kit – Pkg/100:
11 mm Pre-Slit PTFE/Silicone Snap Cap Assembly (Pkg/100)
11 mm 2 mL Clear Snap Vial Kit (Pkg/100)
1
1
N9300697
N9303416
N9303418
11 mm PTFE/Silicone/PTFE Snap Convenience Kit – Pkg/100:
11 mm PTFE/Silicone/PTFE Snap Cap Assembly (Pkg/100)
11 mm 2 mL Clear Snap Vial Kit (Pkg/100)
1
1
N9300698
N9303417
N9303418
10 mm Clear Pre-Slit PTFE/Silicone Screw Cap Convenience Kit – Pkg/100:
10 mm Pre-Slit PTFE/Silicone Screw Cap Assembly (Pkg/100)
10 mm 2 mL Clear Screw Vials with Write-On Patch and Fill Lines (Pkg/100)
1
1
N9300695
N9306052
N9306053
10 mm Amber Pre-Slit PTFE/Silicone Screw Cap Convenience Kit – Pkg/100:
10 mm Pre-Slit PTFE/Silicone Screw Cap Assembly (Pkg/100)
10 mm Amber Screw Top Vials with Write-On Patch and Fill Lines (Pkg/100)
1
1
N9300696
N9306052
N9306057
11 mm PTFE/Silicone Snap Convenience Kit – Pkg/100:
11 mm PTFE/Silicone Snap Cap Assembly (Pkg/100)
11 mm 2 mL Clear Snap Vial Kit (Pkg/100)
1
1
N9300702
N9303419
N9303418
11 mm Red Rubber Crimp Convenience Kit – Pkg/100:
11 mm Red Rubber/Silver Crimp Assembly (Pkg /100)
11 mm 2 mL Clear Vial Kit (Pkg/100)
1
1
N9300502
N9306230
N9306231
11 mm Red Rubber Crimp Convenience Kit – Pkg/500:
11 mm Red Rubber/Silver Crimp Assembly (Pkg/100)
11 mm 2 mL Clear Vial Kit (Pkg/100)
5
5
N9300503
N9306230
N9306231
11 mm PTFE/Silicone Crimp Convenience Kit – Pkg/100:
11 mm PTFE/Silicone Crimp Assembly (Pkg/100)
11 mm 2 mL Clear Vial Kit (Pkg/100)
1
1
N9300500
N9306228
N9306231
11 mm PTFE/Silicone/PTFE Crimp Convenience Kit – Pkg/100:
11 mm PTFE/Silicone/PTFE Crimp Assembly (Pkg/100)
11 mm 2 mL Clear Vial Kit (Pkg/100)
1
1
N9300501
N9306229
N9306231
Certified LC Clean Non-Slit Cap/ViaL Convenience Kit – Pkg/100:
9 mm 2 mL Screw Top Vial with 9 mm Blue Screw Top Cap Clear Non-Slit PTFE/Silicone (LC Clean™)
Certified LC Clean Pre-Slit Cap/ViaL Convenience Kit – Pkg/100:
9 mm 2 mL Screw Top Vial with 9 mm Gray Screw Top Cap Clear Pre-Slit PTFE/Silicone (LC Clean™)
Liquid Chromatography Laboratory Bottle Kits
Description
Part No.
1x5 Liter Bottle with Cap and Teflon Insert, 2 Meters PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit
1x2 Liter Bottle with Cap and Teflon Insert, 1 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit
1x1 Liter Bottle with Cap and Teflon Insert, 1 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit
1x0.5 Liter Bottle with Cap and Teflon Insert, 1 Meter PTFE 1⁄16” Tubing and 1x40 μm SS Solvent Frit
1 Cap with Teflon Insert, 1 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit
1 Cap with Teflon Insert, 1 Meter PTFE 1⁄16” Tubing and 1x40 μm SS Solvent Frit
1x0.5 Liter Bottle with Cap and Dual Teflon Insert, 2 pcs of 2 Meter PTFE 1⁄8” Tubing (Piston Wash Function)
1 Cap with Dual Teflon Insert, 2 pcs of 2 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit (Piston Wash Function)
N2601610
N2601611
N2601612
N2601613
N2601614
N2601615
N2601616
N2601617
Order online at www.perkinelmer.com/supplies
ORDER TODAY
11
Brownlee Conventional Columns from
Which Column Do I Need?
Brownlee
Brownlee
Brownlee
Brownlee
Analytical
Aquapore®
Bio
CHOICE™
Brownlee pH-ex C18
Brownlee Spheri-5®
Brownlee Validated™
Having the right stationary phase for your separation is the first
step in selecting the appropriate column. This should be based
on sample solubility and on chemical differences among the
sample compounds.
Depending on the mode of separation you will use, PerkinElmer
has the right column for you. In reversed-phase separations, the
mobile phase is more polar than the stationary phase. Sample
hydrophobicity also is a major determinant of the separation
mode. In reversed-phase separations, the mobile phase is more
polar than the stationary phase, which is traditionally a straight
alkyl chain, most often C18.
The majority of HPLC analyses are performed in reversed-phase
mode, due to the fact that the analytes of interest can be
dissolved in water, or mixtures of water and a polar organic
solvent such as methanol or acetonitrile.
In normal phase separations, the mobile phase is less polar
than the stationary phase. Cyano phases are commonly used
in either reversed-phase or normal-phase mode. A stationary
phase incorporating both polar and nonpolar functionality can
be used in either reversed-phase or normal-phase mode.
Brownlee Analytical
PerkinElmer’s all-purpose HPLC column line for conventional as well as
high-speed LC separations. The Brownlee Analytical family is available
in 3 or 5 μ, and lengths ranging from 30 – 250 mm, in 2.1 mm and
4.6 mm i.d.
Brownlee Aquapore
®
Brownlee Validated ™
These columns are made on high-purity Type B silica with inherent low
silanophilic activity. They exhibit excellent peak shape for a wide range
of compounds, while also having a wide number of phases. Columns
are available in 3 or 5 μ, and lengths ranging from 30 – 250 mm, in
2.1 mm or 4.6 mm i.d.
Brownlee Columns for HRes ™ Fast-LC
Recent developments in LC column technology have now made the
use of sub 3 μm particle packing materials practical. These smaller
particle size materials allow higher mobile phase linear velocities to be
used, without the decrease in separation efficiency experienced with
conventional larger particle size packings. This translates into higher
throughput and higher productivity. To conserve mobile phase, these
sub 3 μm column materials are typically packed into 2.1 mm i.d.
columns so that flow rates (mobile phase volume) are kept low.
However, smaller sized packings result in elevated operating pressures.
Technological advances in pump and injector designs have also
kept pace, and these columns can be used at pressures as high as
10,000 psi with the PerkinElmer Series 275 or up to 15,000 psi using
FX15 LC systems.
The rugged construction of this new line of small particle columns for
high pressure application yield excellent longevity and reproducibility.
These packings exhibit an exceptionally tight particle size distribution
for excellent resolving power and are packed at elevated pressures to
assure column stability even at high pressure applications. Each
column is tested to ensure the highest level of quality and efficiency
in high pressure LC testing.
Features and Benefits
■
Sub 3 μm particle technology and 2.1 mm i.d. for higher
separation efficiency
■
Packed to withstand higher operating pressures
■
Wide choice of stationary phases
This is a wide-pore silica-based support suitable for the separation of
large biopolymers.
Brownlee Bio
Wide-pore silica that is excellent for peptide and protein separation.
Columns are available in 5 μ, and lengths ranging from 30 – 250 mm,
in 2.1 mm and 4.6 mm i.d.
Brownlee CHOICE ™
This line of columns is made of 60 Å silica which results in large
surface area, high carbon loads and high retention compounds.
Columns are available in 3 or 5 μ, and lengths ranging from
30 – 250 mm, in 2.1 mm and 4.6 mm i.d.
Brownlee pH-ex C18
Brownlee pH-ex C18, HPLC columns utilize a patented polycarbosilane
barrier layer that protects the silica particles from extremely basic
conditions. This layer uses multiple attachment points to the silica
particle which yields a modified surface with enhanced stability.
A second layer is then attached, providing the functional group (C18).
Using this approach to shield the silica surface, a highly durable
stationary phase is created. These columns are designed to be used in
a pH range of 1 – 12 and have shown no loss of efficiency after 50
hours in a pH of 12 at 60 °C.
Brownlee Spheri-5 ®
This is small-pore silica-based sorbent for separating small molecules.
Both monofunctional (comb-pre) and polyfunctional (polymerized
loop-type) C8 and C18 sorbents available.
12
Description
Brownlee HRes Biphenyl
Brownlee HRes Biphenyl
Brownlee HRes Biphenyl
Brownlee HRes PFP Propyl
Brownlee HRes PFP Propyl
Brownlee HRes PFP Propyl
Brownlee HRes Aqueous C18
Brownlee HRes Aqueous C18
Brownlee HRes Aqueous C18
Brownlee HRes IBD
Brownlee HRes IBD
Brownlee HRes IBD
Brownlee HRes Analytical C18
Brownlee HRes Analytical C18
Brownlee HRes Analytical C18
Brownlee HRes Analytical DB Silica
Brownlee HRes Analytical DB Silica
Brownlee HRes Analytical DB Silica
Brownlee HRes Analytical DB Cyano
Brownlee HRes Analytical DB Cyano
Brownlee HRes Analytical DB Cyano
Brownlee HRes Analytical DB PAH
Brownlee HRes Analytical DB PAH
Length
i.d.
Particle
Size
Part No.
30 mm
50 mm
100 mm
30 mm
50 mm
100 mm
30 mm
50 mm
100 mm
30 mm
50 mm
100 mm
30 mm
50 mm
100 mm
30 mm
50 mm
100 mm
30 mm
50 mm
100 mm
50 mm
100 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
2.1 mm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 μm
1.9 um
1.9 um
1.9 um
1.9 um
1.9 um
1.9 um
1.9 um
1.9 um
N9303911
N9303912
N9303913
N9303914
N9303915
N9303916
N9303917
N9303918
N9303919
N9303920
N9303921
N9303922
N9303852
N9303853
N9303854
N9303970
N9303971
N9303972
N9303973
N9303974
N9303975
N9303995
N9303996
Consult your area sales representative for quanity discounts
See page 2 for ordering information and a complete listing of PerkinElmer offices.
PerkinElmer
Brownlee Columns
Choose only genuine PerkinElmer BrownleeTM columns
for the best separation results. Six different column
types to meet all your analytical needs.
Features and Benefits
■
Each column individually tested and certificate provided
■
End fittings compatible with a variety of HPLC systems
■
Do not require MPLC holders
Conventional columns do not require MPLC holders.
Conventional Columns
Column
Functionality
Analytical
Analytical
Analytical
Analytical
Analytical
Analytical
Analytical
Aquapore®
Aquapore
Aquapore
Bio
Bio
CHOICE™
Amino
C18 & C8
Cyano
Biphenyl
Phenyl
Silica
PAH
AX-300
Octyl C8
ODS C18
C18
C8
Basix
Pore Diameter Å
% Carbon
End Cap
110
110
110
110
110
110
110
300
300
300
300
300
60
2
13
4
–
6
–
–
–
–
–
6
–
12
No
Yes
Yes
Yes
Yes
–
Yes
–
–
–
Yes
–
Yes
CHOICE
CHOICE
CHOICE
CHOICE
C18
Biphenyl
Organic acids
PFP propyl
60
60
60
60
27
23
–
17
Yes
Yes
No
Yes
Spheri-5®
C8, C18, C18 ODS and Silica
80
–
Validated™
Validated
Validated
Validated
Validated
Amino
C1
C4
Aqueous C18
C18
100
100
100
100
100
2
5
9
15
20
No
–
Yes
No
Yes
Validated
Validated
Validated
Validated
Validated
Validated
C8
Carbamate
Cyano
IBD
PFP
Phenyl
100
100
100
100
100
100
12
–
8
12
7
10
Yes
–
Yes
No
Yes
Yes
Validated
Quat
100
–
–
–
Applications
Excellent for carbohydrate analysis
Superior for non-basic analytes
General purpose for normal or reversed-phase
U.S. EPA Method 8330
General purpose for neutral analytes
Ideal for polar analytes
Maximum resolution of polynuclear aromatic hydrocarbons
Used for ion exchange chromatography
Used for reversed-phase chromatography
Silica based support used for the separation of large biopolymers
High molecular weight compounds and proteins
High molecular weight compounds and proteins
Ideal for LC/MS. Excellent for amine-containing compounds
and basic pharmaceuticals
Excellent for explosives or steroids
Highly retentive and selective phase for aromatic compounds
Used for challenging organic acids
Ideal for MS, ELSD, or NPD detection of nucleosides, nucleotides,
purines, pyrimidines or halogenated compounds
Excellent for separating small molecules both
non-functional and polyfunctional
Ideal for carbohydrates
Least retentive reversed-phase hydrocarbon packing
High bonding coverage and base deactivation
Excellent for highly water-soluble or poorly organic-soluble compounds
Used for the detection of anilines, barbiturates, carbonyls, fat-soluble
vitamins, fatty acids, glycerides, phthalates
Less hydrophobic retention than C18
Fast analysis of carbamates
Basic pharmaceuticals and steroids
Unique separation for acids, bases, zwitterions and other polar compounds
Ideal for taxors and precursors or halogenated compounds
Separation of fatty acids, polynuclear aromatic hydrocarbons,
purines and pyrimidines
High purity, base deactivated reversed-phase packing
Order online at www.perkinelmer.com/supplies
ORDER TODAY
13
Conventional Columns for all HPLC
Extensive column selection
meets all your analytical needs
Brownlee Analytical/Specialty
Columns
pH Range: 2.5 to 7.5
Length
i.d.
Particle Temp.
Size
Limit
Pore
Size
Carb.
Load
End
Cap
Length
Part No.
Brownlee Analytical Amino
Ideal for mono and disaccharide analyses. Most popular amino-based stationary
phase. Routine analysis of simple sugars, using isocratic elution and a refractive
index detector or an evaporative light scattering detector.
100 mm
150 mm
4.6 mm
4.6 mm
5 μm
5 μm
80 °C
80 °C
110 Å
110 Å
2%
2%
No
No
N9303503
N9303504
Brownlee Analytical C8
Shorter retention times for hydrophobic compounds. Reliable performance
with symmetrical peak shapes for neutral to acidic compounds.
100 mm
150 mm
4.6 mm
4.6 mm
5 μm
5 μm
80 °C
80 °C
110 Å
110 Å
7%
7%
Yes
Yes
Brownlee Bio
i.d.
Particle Temp.
Size
Limit
150 mm
150 mm
2.1 mm
4.6 mm
5 μm
5 μm
110 Å
110 Å
110 Å
13%
13%
13%
Yes
Yes
Yes
N9303507
N9303512
N9303513
150 mm
150 mm
5 μm
80 °C
110 Å
4%
Yes
N9303522
Specifically designed for challenging analyses
of polynuclear aromatic hydrocarbons.
3.2 mm
2.1 mm
5 μm
5 μm
80 °C
80 °C
110 Å
110 Å
Yes
Yes
N9303430
N9303530
Unique selectivity especially for aromatic compounds.
4.6 mm
5 μm
80 °C
N9303658
N9303659
2.1 mm
4.6 mm
5 μm
5 μm
300 Å
300 Å
5%
6%
Yes
Yes
i.d.
pH Range: 2.5 to 7.5
Particle Temp. Pore
Size
Limit Size
Carb.
Load
End
Cap
Part No.
4.6 mm
5 μm
80 °C
60 Å
12%
Yes
N9303618
27%
27%
27%
12%
Yes
Yes
Yes
Yes
N9303620
N9303621
N9303627
N9303628
Brownlee CHOICE C18
Excellent choice for LC/MS. Highly retentive phase
for hydrophobic and slightly polar analytes.
2.1 mm
4.6 mm
2.1 mm
4.6 mm
3 μm
3 μm
5 μm
5 μm
80 °C
80 °C
80 °C
80 °C
60 Å
60 Å
60 Å
60 Å
Brownlee CHOICE Organic Acids
110 Å
6%
Yes
N9303524
150 mm
250 mm
4.6 mm
2.1 mm
5 μm
5 μm
80 °C
80 °C
60 Å
60 Å
N9303631
N9303632
Brownlee Analytical Silica
Brownlee CHOICE Propyl
Good general purpose packing for normal phase separations.
Highly retentive for basic analytes. Excellent separation of nucleosides,
nucleotides, purines, pyrimidines, halogenated compounds, beta blockers
and tricyclic antidepressants.
150 mm
4.6 mm
5 μm
80 °C
110 Å
Yes
N9303525
150 mm
4.6 mm
5 μm
80 °C
60 Å
17%
Yes
For a full listing of Brownlee
conventional columns, please visit:
www.perkinelmer.com/lcsupplies
14
N9303648
N9303649
Enhanced retention and selectivity for polar organic acids. Retention is stable and
reproducible even with 100% aqueous mobile phase specified in the AOAC method.
Brownlee Analytical Phenyl
150 mm
Yes
Yes
Excellent choice for analytes containing amine group functionality.
100 mm
100 mm
150 mm
150 mm
Brownlee Analytical PAH
150 mm
250 mm
6%
6%
Brownlee CHOICE Basix
150 mm
Suitable for analyses of a wide range of compounds from acidic through
slightly basic. Highly-base-deactivated spherical silica.
4.6 mm
300 Å
300 Å
N9303515
N9303517
Brownlee Analytical Cyano
150 mm
Part No.
Excellent for separating peptides or proteins. Wide-pore HPLC column.
Length
80 °C
80 °C
80 °C
End
Cap
Brownlee Bio C18
Brownlee Choice
3 μm
5 μm
5 μm
Carb.
Load
Wide-bore HPLC column. High proportion of pore/surface
area available for large molecule separations.
Suitable for a wide range of acidic to neutral hydrophobic compounds.
Excellent all purpose column.
4.6 mm
4.6 mm
4.6 mm
Pore
Size
Brownlee Bio C8
Brownlee Analytical C18
100 mm
100 mm
150 mm
pH Range: 2.5 to 7.5
See page 2 for ordering information and a complete listing of PerkinElmer offices.
N9303644
Instruments
Brownlee Spheri-5®
Brownlee Validated
Length
i.d.
pH Range: 2.5 to 7.5
Particle Temp. Pore
Size
Limit Size
Carb.
Load
End
Cap
Length
Part No.
Brownlee Validated Amino
Good for normal phase analytes of mono-and disaccharides or similar compounds.
150 mm
4.6 mm
5 μm
80 °C
100 Å
2%
N9303534
i.d.
Particle Temp. Pore
Size
Limit Size
250 mm
4.6 mm
5 μm
150 mm
Brownlee Spheri-10 C18
100 Å
15%
N9303546
Least retentive reversed phase hydrocarbon packing.
4.6 mm
5 μm
80 °C
07120012
100 Å
4.6 mm
5 μm
07120016
Small pore silica-based sorbent for separating small
molecules both non-functional and polyfunctional.
Brownlee Validated C1
150 mm
5%
N9303718
250 mm
4.6 mm
10 μm
07120001
Brownlee Validated C4
Brownlee pH-ex C18
High bonding coverage and base deactivation.
Less retention that C18 or C8 phases.
150 mm
4.6 mm
5 μm
80 °C
100 Å
9%
Yes
N9303720
Retentive, high purity-base deactivated reversed phase packing.
2.1 mm
4.6 mm
5 μm
5 μm
80 °C
80 °C
80 Å
80 Å
12%
12%
Yes
Yes
N9303566
N9303567
Brownlee Validated C18
pH Range:
1.0 to 12.0
Especially useful for applications requiring high/low pH
ranges (1–12). A silica based C18 column with exceptional stability.
Brownlee Validated C8
150 mm
150 mm
Part No.
Small pore silica-based sorbent for separating small
molecules both non-functional and polyfunctional.
250 mm
80 °C
End
Cap
Brownlee Spheri-5 C8
Highly base deactivated. Compatible with highly aqueous mobile phases.
5 μm
Carb.
Load
Brownlee Spheri-5 C18
Brownlee Validated Aqueous C18
4.6 mm
pH Range: 2.5 to 7.5
Length
i.d.
Particle Temp. Pore
Size
Limit Size
30 mm
50 mm
100 mm
150 mm
4.6 mm
4.6 mm
4.6 mm
4.6 mm
3 μm
3 μm
3 μm
3 μm
80 °C
80 °C
80 °C
80 °C
Carb.
Load
End
Cap
140 Å
140 Å
140 Å
140 Å
Part No.
N9303855
N9303856
N9303857
N9303858
Excellent general purpose phase column. Retentive high purity packing.
150 mm
150 mm
2.1 mm
4.6 mm
5 μm
5 μm
80 °C
80 °C
100 Å
100 Å
20%
20%
Yes
Yes
N9303556
N9303558
Brownlee Validated Carbamate
A unique stationary phase specifically designed for carbamate analysis.
This column is compatible with fluorescence or LC/MS detection, and is
designed for fast analysis times, reducing solvent usage.
100 mm
4.6 mm
3 μm
80 °C
100 Å
N9303569
Brownlee Validated Cyano
High purity Cyano phase with few silanol sites. Less sensitive
to small amounts of water present in the mobile phase.
150 mm
4.6 mm
5 μm
80 °C
100 Å
10%
Yes
N9303575
3 μm
5 μm
80 °C
80 °C
100 Å
100 Å
i.d.
Particle Temp. Pore
Size
Limit Size
Carb.
Load
End
Cap
Part No.
Method Validation Column Kit
Includes set of three identical Brownlee Validated C18 columns from different lots.
Ideal to check robustness in the method validation process. Packing materials of
varying lot #’s.
4.6 mm
5 μm
N9303950
C18 Lot Specific Column Kit
Includes 3 Brownlee Validated C18 columns. Ideal tool for the R & D and Contract
Lab applications working on specific projects and studies. Identical lot# specific
packing material guaranteed. Absolute minimal variability and one convenient kit
for long-term use.
Unique selectivity and a high level of base-deactivation.
Reduces or eliminates the need for mobile phase additives.
4.6 mm
4.6 mm
Length
150 mm
Brownlee Validated IBD
150 mm
150 mm
Conventional Column Kits
12%
12%
N9303593
N9303582
150 mm
4.6 mm
5 μm
N9303951
Brownlee Validated PFP
Unique selectivity for compounds containing organohalogens
or other basic functional groups.
150 mm
4.6 mm
5 μm
80 °C
100 Å
7%
Yes
N9303599
Brownlee Validated Phenyl
High purity, highly retentive base-deactivated phase,
especially designed for aromatic analytes.
150 mm
4.6 mm
5 μm
80 °C
100 Å
10%
Yes
N9303606
Purchase 2 or more on
Brownlee Cartridge
Columns and Save!!!!
Consult your authorized PERKINELMER
Sales Representative for Volume Discounts
and Promotions
Order online at www.perkinelmer.com/supplies
ORDER TODAY
15
Brownlee Cartridge Columns for Quality
Brownlee Sorbents
PerkinElmer Brownlee™ cartridge columns are offered in a wide range of
sorbent material. Choose the right sorbent for the analysis and mode of
separation being used.
Aquapore® – is a wide-pore, silica-based support suitable for the
separation of large biopolymers.
Spheri-5® – is a small-pore, silica-based solvent for separating small
molecules. Both monofunctional (comb-type) and polyfunctional
(polymerized loop-type) C8 and C18 sorbents are available.
Polypore® – is a polymer-based (microporous, 10 μm) sorbent for the
analysis of organic acids and sugars.
Validated™ – is a small-pore, silica-based C18 sorbent for small
molecules, specifically for consistent pharmaceutical assays.
Pecosphere™ – is a small-pore, silica-based sorbent for HPLC
of small molecules.
Reduced Activity – is a small-pore, base deactivated silica-based,
reversed-phase sorbent (C18 or C8) developed for HPLC of basic
analytes and pharmaceuticals.
CHOICE™ – is a small-pore, base deactivated silica-based,
reversed-phase sorbent (C18) developed for LC/MS separations.
Peco HCODS – is especially suited for reversed-phase separation of
proteins and peptides.
Brownlee Cartridge Columns
16
Column
Functionality
Pore Diameter Å
% Carbon
End Cap
Aquapore
Aquapore
Aquapore
Aquapore
Choice
Choice
Choice
Pecosphere
Pecosphere CR
Pecosphere CR
Peco HCODS
Polypore
Polypore
Reduced Activity
AX-300 (anion exchange)
OD-300 (C18)
RP-300 (C8)
BU-300 (C4)
C18
C8
PFPP (Pentafluorophenylpropyl)
C18, monofunctional
C18
C8
C18, polyfunctional
CA (calcium form), Mixed Mode
H (hydrogen form), Mixed Mode
C18
300
300
300
300
100
100
100
80
80
80
300
Microporous
Microporous
80
10
5
3
12
7
5
11
11
11
9
12
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Reduced Activity
Spheri-5
Spheri-5
Spheri-5
Spheri-5
C8
RP-18 (monofunctional C18)
ODS (polyfunctional C18)
RP-8 (monofunctional C8)
Phenyl (C5)
80
80
80
80
80
5
11
14
6
6
Yes
Yes
Yes
Yes
Yes
Spheri-5
Spheri-5
Spheri-5
Validated
Amino
Cyano
Silica
C18
80
80
80
100
3
4
18
No
No
Yes
VeloSep
VeloSep
RP-18 (C18)
RP-8 (C8)
100
100
14
7
Yes
Yes
Applications
Silica-based support for larger anionic compounds
Silica-based support for larger compounds by reversed-phase
Same as above, but for slightly more polar compounds
Same as above, but for even somewhat more polar compounds
For high speed/efficiency separation of basic compounds/pharmaceuticals
For high speed/efficiency separation of basic compounds/pharmaceuticals
For high speed/efficiency separation of basic drugs, especially for LC/MS
Reversed-phase column for fast separation of smaller compounds
Same as above, but for more basic compounds
Same as above, but, also, for slightly more polar compounds
Especially suited for reversed-phase separation of proteins and peptides
Especially suited for separation of organic acids, as well as sugars
Especially suited for separation of sugars, as well as organic acids
Reversed-phase sorbent geared for fast separation of basic
compounds/pharmaceuticals
Same as above, but for slightly more polar compounds
Reversed-phase separation of smaller compounds
Same as above, but with somewhat different selectivity
Reversed-phase separation of more basic smaller compounds
Especially suited for hydrophobic interaction separation of biomolecules,
where the activity of the compound must be preserved
Normal-phase separation of smaller, relatively more polar compounds
Same as above, but with somewhat different selectivity
Same as above, but with different selectivity
Reversed-phase separations in which very little variation in both
lot-to-lot and column-to-column variability can be tolerated
Reversed-phase column for high through-put and minimal solvent usage
Same as above, but for slightly more polar compounds
See page 2 for ordering information and a complete listing of PerkinElmer offices.
and Flexibility
Brownlee ™ Analytical Cartridge Columns
for conventional and narrowbore HPLC
Analytical cartridges from the Brownlee line are available in three
lengths (30, 100 and 220 mm) and two internal diameters (4.6 and 2.1
mm). The MPLC cartridge system allows direct coupling of a cartridge
to a guard without any dead-volume. Changing cartridges is easy with
the finger-tight cartridge design, which does not require any wrench
tightening of the holder or disconnecting of tubing from the LC system.
Peco MPLC holders (83 and 33 mm).
Brownlee VeloSep ®
Features and Benefits
■
Quality – manufactured under ISO-9001 certified quality
control procedures
■
Quick and easy cartridge change with the finger-tight design
■
Flexible – same reusable holder for 2.1 and 4.6 mm cartridges
■
Economical – less expensive than conventional columns
Brownlee CHOICE ™
The CHOICE™ columns provide the speed and efficiency appropriate
for LC/MS. Each column’s separation requirements vary depending on
the system, sample and mass spectrometer.
Brownlee PECO
PerkinElmer pioneered the development of Fast HPLC and introduced
the popular 3 x 3 column. This column is capable of rapid analysis, as
short as one to two minutes. The 83 mm long 3 x 8 column with >
10,000 plates can separate many complex mixtures in less than 10
minutes. Peco cartridges are available with MPLC® holders. Three
cartridge lengths (33, 83 and 150 mm) are available in 4.6 mm i.d.
Brownlee Preparative
Preparative columns are 10 mm i.d. cartridges, packed with Aquapore®
20 μm, 300 Å sorbents. Save time with high-pressure preparative runs
up to 3000 psi and achieve high performance with the 20 μm, 300 Å
sorbents. Typical sample capacity of the 250 mm cartridge is 50 mg to
1 g of material; the typical flow rate is 4 – 10 mL/min.
For a full listing of Brownlee
cartridge columns, please visit:
www.perkinelmer.com/lcsupplies
VeloSep columns are 3.2 mm i.d. cartridges packed with 3 μm
reversed-phase support for high throughput analysis and reduced
solvent consumption. VeloSep is packed with 3 μm C8 or C18 sorbents
and available in 40 or 100 mm lengths.
Brownlee Validated
Brownlee Validated sorbent is derived from a neutral “Type B” silica
with inherent low silanophobic activity. Each sorbent is tested to meet
stringent specifications for the separation of basic, neutral and acidic
test probes. A high-temperature bonding technique is coupled with an
exhaustive end-capping procedure to ensure maximum coverage of the
silica surface. A proprietary treatment step is used to further eliminate
any trace residual metals in the silica that create active absorptive
sites. This is a highly deactivated column which yields excellent peak
shape for difficult base analytes, pharmaceuticals and small peptides.
NewGuard Columns
NewGuard cartridges are small guard cartridges (15 mm x 3.2 mm i.d.)
packed with 5 or 7 μm sorbents. NewGuard columns prolong column
life 2 to 5 times by eliminating particulates, contaminants and strongly
bound sample components. They act as disposable, replaceable heads
of your analytical columns. NewGuard columns are easily coupled to
MPLC cartridges or conventional columns.
Brownlee MPLC/Peco Holders
MPLC cartridge system ensures leak-free operation up to 7000 psi,
with only finger-tightening. The high-pressure seal in each end
assembly actually seals tighter as pressure increases. No wrenches are
required and there is no need to disconnect any tubing to your LC
system when changing a cartridge. MPLC cartridges can be directly
coupled to another using a union.
Purchase 2 or more Brownlee
Cartridge Columns and Save!!!
Consult your authorized PERKINELMER Sales Representative for Volume Discounts and Promotions.
Delivering enhanced VALUE and outstanding SAVINGS on the products you use most!
Order online at www.perkinelmer.com/supplies
ORDER TODAY
17
Brownlee MPLC Cartridge Columns for
Brownlee cartridge columns
offer an extensive range of
phases and column lengths
Ion Exchange
Column
AX-300, Aquapore®
Description
30 mm x 4.6 mm i.d.*
2 per package
Part No.
30 mm x 2.1 mm i.d.*
2 per package
Part No.
100 mm x 4.6 mm i.d.**
1 per package
Part No.
7 μm, 300 Å, weak anion
07110073
07110074
07110075
Polypore CA
10 μm, polymeric, calcium form
07110091
07110093
Polypore H
10 μm, polymeric, hydrogen form
07110085
07110087
Description
30 mm x 4.6 mm i.d.*
2 per package
Part No.
Aminopropyl, 5 μm, 80 Å
07110037
07110039
Cyanopropyl, 5 μm, 80 Å
07110043
07110045
®
Polar Phase
Column
Amino, Spheri-5
®
Cyano, Spheri-5
Silica, Spheri-5
5 μm, 80 Å
07110031
Silica, Spheri-10
10 μm, 80 Å
07110145
30 mm x 2.1 mm i.d.*
2 per package
Part No.
100 mm x 4.6 mm i.d.**
1 per package
Part No.
07110032
07110033
Description
30 mm x 4.6 mm i.d.*
2 per package
Part No.
30 mm x 2.1 mm i.d.*
2 per package
Part No.
100 mm x 4.6 mm i.d.**
1 per package
Part No.
BU-300, Aquapore Butyl C-4
7 μm, 300 Å
07110061
07110062
Cyano, Spheri-5
Cyanopropyl, 5 μm, 80 Å
07110043
OD-300, Aquapore ODS
C-18, 7 μm, 300 Å
07110235
07110234
07110232
ODS, Spheri-5
C-18, polyfunctional, 5 μm, 80 Å
07110019
07110020
07110021
Phenyl, Spheri-5
Phenyl, 5 μm, 80 Å
07110025
RP-8, Spheri-5
C-8, monofunctional, 5 μm, 80 Å
07110001
RP-18, Spheri-5
C-18, monofunctional, 5 μm, 80 Å
07110013
07110014
07110015
RP-300, Aquapore Octyl C-8
7 μm, 300 Å
07110055
07110056
07110057
Pecosphere C18
C-18, monofunctional, non-reduced, 3μm, 80A
02580164
Pecosphere 3CR ***
C-8, Base Deactivated, 3 μm
02580191
Pecosphere 3CR ***
C-18, Base Deactivated, 3 μm
02580195
Reversed Phase
Column
07110045
07110027
07110002
07110003
0258-0220
Pecosphere C18 100 x 3.2 mm monofunctional, non-reduced, 3 um, 80A column 0258-0221
* Requires Holder (07150013)
18
** Requires Holder (07150014)
*** Pack of 5
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Choice and Variety
Scavenger Columns
Column
Description
33 mm x 4.6 mm i.d.*
5 per package
Part No.
Silica Scavenger
10 μm
02580203
C18 Scavenger
Monofunctional, 10 μm, 80A
02580202
Ion Exchange
Column
100 mm x 2.1 mm i.d.**
1 per package
Part No.
Description
220 mm x 4.6 mm i.d.***
1 per package
Part No.
AX-300, Aquapore
7 μm, 300 Å, weak anion
07110077
Polypore® CA
10 μm, polymeric, calcium form
07110095
Polypore H
10 μm, polymeric, hydrogen form
07110089
220 mm x 2.1 mm i.d.***
1 per package
Part No.
Polar Phase
100 mm x 2.1 mm i.d.**
1 per package
Part No.
220 mm x 4.6 mm i.d.***
1 per package
Part No.
Column
Description
Amino, Spheri-5
Aminopropyl, 5 μm, 80 Å
07110041
Cyano, Spheri-5
Cyanopropyl, 5 μm, 80 Å
07110047
Silica, Spheri-5
5 μm, 80 Å
07110035
220 mm x 2.1 mm i.d.***
1 per package
Part No.
Reversed Phase
Column
Description
100 mm x 2.1 mm i.d.**
1 per package
Part No.
BU-300, Aquapore Butyl C-4
7 μm, 300 Å
07110064
Cyano, Spheri-5
Cyanopropyl, 5 μm, 80 Å
OD-300, Aquapore ODS
C-18, 7 μm, 300 Å
07110233
07110231
07110236
ODS, Spheri-5
C-18, polyfunctional, 5 μm, 80 Å
07110022
07110023
07110024
Phenyl, Spheri-5
Phenyl, 5 μm, 80 Å
RP-8, Spheri-5
C-8, monofunctional, 5 μm, 80 Å
C-18, Base Deactivated, 3 μm
RP-18, Spheri-5
C-18, monofunctional, 5 μm, 80 Å
07110047
07110004
07110005
07110006
07110016
07110017
07110018
07110059
07110060
Pecosphere 3CR
C-8, Base Deactivated, 3 μm
RP-300, Aquapore Octyl C-8
7 μm, 300 Å
07110058
Pecosphere C18
C-18, monofunctional, nonreduced, 3 μm, 80 Å
0258-0220
** Requires Holder (07150014)
220 mm x 2.1 mm i.d.***
1 per package
Part No.
07110029
Pecosphere 3CR
* Requires Holder (07150028)
220 mm x 4.6 mm i.d.***
1 per package
Part No.
*** Requires Holder (07150015)
Order online at www.perkinelmer.com/supplies
ORDER TODAY
19
Brownlee NewGuard Cartridge Columns
Guard Cartridge Columns and
Accessories
NewGuard Columns
NewGuard cartridges are small guard cartridges (15 mm x 3.2 mm i.d.)
packed with 5 or 7 μm sorbents. NewGuard cartridges prolong column
life by eliminating particulates, contaminant's, and strongly bound
sample components. They act as replaceable, disposable heads of
your analytical columns. There is negligible loss of efficiency and
little effect on retention or resolution. NewGuards are available in a
convenient 3-pack and can be coupled directly to any MPLC cartridge
with a union (07150018).
NewGuard cartridges directly coupled to a 220 mm MPLC
cartridge and connected externally to a 250 mm conventional column.
Features and Benefits
■
Prolong column life by 2 to 5 times
■
Protect your column from particulates and strongly bound
sample components
■
Optimized dimensions to prevent loss of resolution
■
Easy coupling to MPLC cartridges or conventional columns
■
Finger-tight seal to 7000 psi using NewGuard holders
■
Can be used for sample preconcentration
(connected to sample injection loop)
View of the NewGuard holder
and a NewGuard 3/pack.
15 mm cartridge*, 3.2 mm i.d., 3 per pkg.
Standards Solutions
Description
Part No.
Test Mix
Amino, Aquapore® Amino, 7 μm spherical
Anion, Aquapore Anion, 7 μm spherical
Cyano, Aquapore Cyano, 7 μm spherical
Diol, Aquapore Diol, 7 μm spherical
Phenyl, Aquapore Phenyl, 7 μm spherical
RP-2, Aquapore Dimethyl, 7 μm spherical
RP-4, Aquapore Butyl, 7 μm spherical
RP-8, Aquapore Octyl, 7 μm spherical
RP-18, Aquapore ODS, 7 μm spherical
Silica, Aquapore Silica, 7 μm spherical
Validated®, C18, 5 μm spherical
07110098
07110102
07110100
07110105
07110096
07110086
07110088
07110090
07110092
07110106
00402237
Description
Part No.
LC Gradient Test Mix
Universal test mix for reversed-phase (5 mL/pkg.)
N9334010
00890893
Standards
Description
Part No.
HPLC SV Calibration Mix #5/610 PAH
HPLC 610 Calibration Mix A
HPLC 610 Calibration Mix B
00891542
00891543
00891544
* Requires holder (07150001)
Note: Actual bed length of NewGuard is about 13 mm
Replacement Seals for MPLC and Prep-10 Holders
20
Item
Description
Part No.
Prep-10 Inlet Seal
Prep-10 Outlet Seal
Seals for MPLC Holders
Seal Replacement Kit for MPLC Holders
One each (Prep-10 Seal Replacement Kit tools required)
One each (Prep-10 Seal Replacement Kit tools required)
Two 7000 psi seals (Seal Replacement Kit tools required)
Tools and two 7000 psi seals
07150012
07150026
07150024
07150023
See page 2 for ordering information and a complete listing of PerkinElmer offices.
and Holders for choice and variety
MPLC/Peco™ Holders
The patented MPLC cartridge system ensures leak-free operation up to 7000 psi, with only finger-tightening. The high-pressure seal in each end assembly actually seals
tighter as pressure increases. No wrenches are required, and there is no need to disconnect any tubing to your LC system when changing a cartridge. Each MPLC cartridge
can be directly coupled to another using a union.
Name
Description
Part No.
Universal Holder Kit
07150025
33 mm Pecosphere Holder
Includes 100 and 220 mm holder bodies,
2 end assemblies, 1 union, 1 NewGuard end assembly.
Holds a single NewGuard cartridge or a single 20 mm
CHOICE™ cartridge.
Holds a single MPLC and CHOICE 30 mm cartridge.
(Do Not use with Pecosphere column)
Holds 33 mm Fast LC Peco cartridge only.
50 mm Holder
83 mm Peco Holder
Holds a single 50 mm CHOICE cartridge only.
Holds 83 mm Fast LC Peco cartridge only.
N2580030
07150029
100 mm Holder
Holds a single MPLC 100 mm cartridge.
07150014
150 mm Holder
Holds a single MPLC 150 mm cartridge.
07150030
220 mm Holder
Holds a single MPLC 220 mm cartridge.
07150015
250 mm Holder
100 mm NewGuard
System Holder
220 mm NewGuard
System Holder
130 mm MPLC
System Holder
Union
Holds a single MPLC 250 mm cartridge.
Holder for a NewGuard and a 100 mm coupled cartridge.
07150031
07150016
Holder for a NewGuard
and a 220 mm coupled cartridge.
Holder for a 30 and 100 mm coupled cartridge.
07150017
For direct coupling of 2 cartridge holders.
(Two holder bodies and 2 end assemblies also required.)
Upgrades a 30 mm holder to a NewGuard holder.
07150018
07150002
Holder component.
07150019
30 mm Holder Body
Holder component.
07150020
100 mm Holder Body
Holder component.
07150021
220 mm Holder Body
Holder component.
07150022
NewGuard® Holder
30 mm Holder
NewGuard
End Assembly
End Assembly
07150001
07150013
07150028
07150032
Prep-10 Cartridge Holders
Name
Description
Part No.
100 mm Prep-10 Holder
Holds a single 100 mm Prep-10 cartridge.
07150005
250 mm Prep-10 Holder
Holds a single 250 mm Prep-10 cartridge.
07150006
Order online at www.perkinelmer.com/supplies
ORDER TODAY
21
sample loops
Stainless Steel Sample Loops for
Flexar FX UHPLC Autosampler
(up to 18,000 psi operation)
SS loops required for use with FX-10 or FX-15 systems operating
above 6,200 psi. Compatible with Series 275 autosampler.
Interferene
High
Pressure
Check
Sample
Standards
Loops
Description
Part No.
2 μL Sample Loop, SS
5 μL Sample Loop, SS
10 μL Sample Loop, SS
20 μL Sample Loop, SS
50 μL Sample Loop, SS
100 μL Sample Loop, SS
200 μL Sample Loop, SS
500 μL Sample Loop, SS
1 mL Sample Loop, SS
2 mL Sample Loop, SS
5 mL Sample Loop, SS
N2936071
N2936056
N2936057
N2936058
N2936059
N2936060
N2936061
N2936062
N2936063
N2936064
N2936065
Size
10 μL
50 μL
100 μL
200 μL
5 mL
Model
7125/7010
Part No.
Model
7725
Part No.
09904938
09904940
09904942
09904818
N9306024
N9306026
N9306027
N9306028
Model
8125
Part No.
41000013
09904818
N9306032
PEEK Sample Loops for Series 200/225
and Flexar LC Autosamplers
(up to 6,200 psi operation)
Note: these loops are compatible with all standard Flexar autosamplers
as well as Series 225 autosamplers. Note: PEEK loops cannot be used
above 6,200 psi operation therefore are NOT compatible eith standard
Flexar autosamplers. Stainless steel loops required for use wirh FX-10
or FX-15 UHPLCsystems operating above 6,200 psi.
Description
Size
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
2 μL
5 μL
10 μL
20 μL
50 μL
100 μL
250 μL
500 μL
1 mL
2 mL
5 mL
Part No.
N2936072
N2936073
N2936074
N2936075
N2936076
N2936077
N2936078
N2936079
N2936080
N2936081
N2936082
PEEK Sample Loops
Sample loops are made from PEEK tubing and fittings. PEEK
(poly-ether-ether-ketone) is a mechanically-strong, chemically-inert
polymer, ideal for HPLC applications where metal surfaces may
interact with the mobile phase or sample component. Each sample
loop is supplied with two PEEK hex-head nuts and ferrules. These
fittings grip the tubing in two locations for a more reliable connection.
Description
Size
PEEK Sample Loop
PEEK Sample Loop
PEEK Sample Loop
Internal Loop (PEEK and Ceramic)
20 μL
50 μL
200 μL
2 μL
Clean-Cut Tubing Cutter
Clean-Cut™ tubing tool is designed to cut Teflon®, Tefzel® and polymers
in general but, in particular, PEEK tubing. The compact design enables
every chromatographer to carry it in his pocket. A unique safety locking
mechanism secures the blade when not in use.
Stainless Steel Sample Loops
22
Sample Loops
and Tubing
Part No.
N9306035
N9306036
N9306038
N9306022
Tubing Accessories
Description
Part No.
Clean-Cut Tubing Cutter
Clean-Cut Tubing Replacement Blade
Cable/Tubing clip (U-Shaped)
ED020015
ED020016
NX598006
PEEK Tubing
PEEK tubing has the strength required to withstand
continuous use at HPLC pressure without
swelling or bursting. The dense polymer
structure of PEEK tubing eliminates the
permeability to organic solvents that causes
Tubing and Connectors
other polymer tubing, such as Tefzel ®, to sweat.
Use PEEK with virtually any organic or inorganic liquid. PEEK tubing is
not affected by halide salts, high-strength buffers or other aggressive
mobile phases that degrade stainless steel.
PEEK Tubing
Description
Length
Part No.
⁄16 in o.d. x 0.007 in i.d.
1
⁄16 in o.d. x 0.010 in i.d.
1
⁄16 in o.d. x 0.005 in i.d. (black)
1
⁄16 in o.d. x 0.004 in i.d. (red)
Connector tubing, Flexar/FX mixer
to injector, SS
Connector tubing, Flexar iso/binary/
quaternary pump to autosampler, SS
5 ft
5 ft
50 cm
50 cm
N9302678
N9302650
N2916200
N2916059
N2916211
1
N2916210
Stainless Steel Tubing
■
Pre-cut and mirror-polished in 316 stainless steel
Description
Length
Part No.
⁄16 in o.d. x 0.015 in i.d.
1
⁄16 in o.d. x 0.007 in i.d.
6 ft
3 ft
00873036
02540838
1
See page 2 for ordering information and a complete listing of PerkinElmer offices.
fingertight fittings
One-piece, easy-to-use
Fingertight® fittings
PEEK Fingertight ® Fittings
High-performance Fingertight® fittings for the most demanding applications.
This PEEK Fingertight® fitting is the toughest with regard to chemical
resistance and pressure. This high-performance Fingertight® fitting is
recommended for the most demanding applications and will resist
pressures up to 6,000 psi (400 bar). Made from a single piece of
PEEK, the size permits tightening without tools.
Description
Part No.
PEEK One-Piece Fingertight Fitting
®
ED020005
Fittings Kits
Fittings: Nuts, Ferrules and Connectors
Stainless steel nuts are available in both Parker-Hannifin and
Rheodyne™ formats. The nuts are used to connect 1⁄16 inch o.d.
stainless steel tubing and feature a 10-32 thread size. PerkinElmer
also offers select SSI fittings for 1⁄16 inch o.d. tubing in 1⁄4 -28 thread size.
Biocompatible Column Fittings for LC. Recommended for users of a
PerkinElmer Biocompatible LC system. Contains nuts, ferrules
and unions.
Part No.
N9301001
Stainless Steel Fittings
Description
Part No.
Kel-F Reverse Ferrule, 1⁄8 inch*
Kel-F Ferrule , 1⁄16 inch*
Parker-Hannifin Ferrule, 1⁄16 inch
Parker-Hannifin Nut, 1⁄16 inch
Parker-Hannifin Nut & Ferrule Kit, 1⁄16 inch
Includes: 6 nuts and 6 ferrules
Parker-Hannifin Zero-Dead-Volume Union
with nuts and ferrules
Parker-Hannifin Medium-Stem SS Nut
Rheodyne™ Ferrule, 1⁄16 inch
Rheodyne™ Nut, 1⁄16 inch long body
Rheodyne™ Nut, 1⁄16 inch short body
Rheodyne™ Nut and Ferrule Kit, 1⁄16 inch
Includes: 6 ferrules, 3 short nuts and 3 long nuts
Tefzel Nut (for Reverse Ferrule), 1⁄8 inch*
Tefzel Fut, 1⁄16 inch*
Valco Ferrule
09903771
09920382
00873032
09903980
00890945
Fittings Kit for LC
All-in-one fittings kit. The kit contains Rheodyne™ and SSI nuts
and ferrules as well as Fingertight ® II nuts and ferrules for toolless
installation. Zero-dead-volume unions are also included. In addition
you receive varying lengths of stainless steel tubing in 0.007 and
0.010 inch i.d.s, as well as 0.30 inch i.d Tefzel® tubing.
Part No.
09903289
N9301002
N2916202
09904947
09904974
09904956
02540274
N2601189
09920381
09903891
Operation Kit
Recommended for purchasers of their first LC. Includes tubing,
union, fittings, syringe, basic LC book and test mix.
Part No.
00890873
*The Tefzel and Kel-F fittings above are only for low pressure use (under 400 psi).
Order online at www.perkinelmer.com/supplies
ORDER TODAY
23
Enhance the Performance of your HPLC
Vacuum kits for all your
degassing requirements
Check Valves
HPLC check valves allow solvent to flow in only the desired direction.
Check valves are easy to install with the torque wrench kit. For all
PerkinElmer pumps an intermediate check valve is required. The input
check valve, which is identical, should be ordered. The check valves of
the biocompatible pumps differ from those of the stainless steel pumps
in that all portions that contact fluid are composed of titanium.
Degassing Kits
Using a solvent degassing system will extend the performance of your
pump. PerkinElmer offers both vacuum degassing systems that can
handle all your degassing requirements.
Series 200 On-Line Vacuum Degasser Kit
This is a low-volume, high efficiency, on-line module for the removal of
dissolved gasses from HPLC solvents. The vacuum degasser is
available in 3 and 5 channel models to support isocratic, binary and
quaternary pumps as well as degassing of autosampler flush solvent.
Description
Part No.
3-channel Vacuum Degassing Package
Includes: a Vacuum Degasser, one 1 L Bottle with Cap,
one 2 L Bottle with Cap, one Organizer Tray and Accessory
5-channel Vacuum Degassing Package
Includes: a Vacuum Degasser, two 1 L Bottle with Caps,
two 2 L Bottles with Caps, Solvent Tray and Organizer
Binary Bottle Cap Kit
Includes: two Caps, Tubing, Fittings and Labels required
for two Solvent Bottles
Quatenary Bottle Cap Kit
Includes: four Caps, Tubing, Fittings and Labels required
for four Solvent Bottles
Inlet/Intermediate
Check valve
Outlet
Check valve
Type
Part No.
Part No.
Standard Stainless Steel
Micropump
Biocompatible Titanium
02540177
02540177
N2600226
02540197
02540197
N2600192
N2600571
N2600570
N2600522
N2600523
Liquid Chromatography Laboratory Bottle Kits
24
Check Valves
Description
Part No.
1x5 Liter Bottle with Cap and Teflon Insert,
2 Meters PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit
1x2 Liter Bottle with Cap and Teflon Insert
1 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit
1x1 Liter Bottle with Cap and Teflon Insert
1 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit
1x0.5 Liter Bottle with Cap and Teflon Insert
1 Meter PTFE 1⁄16" Tubing and 1x40 μm SS Solvent Frit
1 Cap with Teflon Insert
1 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit
1 Cap with Teflon Insert
1 Meter PTFE 1⁄16" Tubing and 1x40 μm SS Solvent Frit
1x0.5 Liter Bottle with Cap and Dual Teflon Insert
2 pcs of 2 Meter PTFE 1⁄8" Tubing (Piston Wash Function)
1 Cap with Dual Teflon Insert
2 pcs of 2 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent
Frit (Piston Wash Function)
N2601610
N2601611
N2601612
N2601613
N2601614
Maintenance Kits and Tools
Description
Part No.
Biocompatible Piston Seal Replacement Kit
Includes: Four Seals, Backup Rings, and O-rings
Check Valve Torque Wrench
Diaphragm for Pulse Compensator
FX-15 UHPLC Pump Accessories Replacement 0.5 μm
filter frits for FX-15 (4-pack)
High pressure FX-15 piston seal kit
Standard Piston Seal Replacement kit for series 200 and Flexar Pump
Includes: Four Seals, Backup Rings, and O-rings
Insertion Tool
Micropump Piston Seal Replacement Kit for series
275 and FX10 pump
Piston wash bottle kit for FX-15
Pulse Compensator Repair Kit
Includes: Diaphragm, Elastomer Plug, and Seal
Seal Removal Tool
Series 200 Bio LC Pump Maintenance Kit
Includes: Fuses, Seals, O-rings, and Seal Tools
Series 200 Pump Maintenance Kit
Includes: Fuses, Seals, O-rings, and Seal Tools
N2910385
02540871
N2601316
N2911224
N2911221
N2910383
N2601503
N2910384
N2601616
N2600313
N2601295
N2910346
N2910345
N2601615
N2601616
N2601617
Replacement Vacuum Degasser Bottles
Description
Part No.
1 L Glass Bottle
2 L Glass Bottle
N2600497
N2600498
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Pump
Static Mixers
Static mixers are used to facilitate complete mobile phase blending,
resulting in improved retention performance. The mixer will most
typically be used where high-pressure blending of two pump outputs
is required. Mixers incorporate a highly efficient crossflow shearing
mechanism which produces vortex sheer mixing over a wide flow range.
UHPLC Static Mixers (up to 18000 psi)
Description
Solvent Sparger and Solvent Filters
Solvent filters remove unwanted particulate matter from the LC
instrument. Spargers connect directly to the solvent delivery line and
are easily removed for cleaning. The scavenger column is ideal for
eliminating particulate material from solvents.
Solvent Spargers, Filters, and Scavengers
Solvent Reservoir Sparger
Description
Size
Stainless Steel
Titanium
Stainless Steel
Titanium
10 μm
10 μm
40 μm
40 μm
Size
In-Line High Pressure Mixer Assembly, SS
In-Line High Pressure Mixer Assembly, SS
In-Line High Pressure Mixer Assembly, SS
In-Line High Pressure Mixer Assembly, SS
In-Line High Pressure Mixer Assembly, SS
Binary T-Mixer, SS
Binary high pressure T-Mixer, SS
HP Binary high pressure T-Mixing, SS
Binary high pressure T-Mixer, SS
Binary high pressure T-Mixer, SS
T-connector, SS
50 μL
150 μL
250 μL
350 μL
500 μL
10 μL
50 uL
150 μL
350 uL
500 uL
Part No.
N2911200
N2911201
N2911202
N2911205
N2911203
N2911170
N2911212
N2911206
N2911210
N2911211
N2911127
Part No.
09903610
N2600070
09903615
N2600089
Solvent Filters/Scavengers
Description
Part No.
In-Line Solvent Filter System
In-Line Solvent Filter Replacement Kit
In-Line Solvent Filter System, Titanium
Replacement 2 μm Titanium Filter Element
Replacement Seal for In-Line Solvent Filter
3cm Scavenger Cartridge Holder
Spheri-5 C18 10μm Scavenger Column (5 pack)
09903606
02540311
N2600259
N2601477
N2601262
02580178
02580202
LC System Accessories
Description
Part No.
Solvent waste cup
90° Elbow adapter, 1⁄4" ID HDPP
Tubing clip (U-shaped, polypropylene)
N2916019
09220102
NX598006
Analytical Static Mixers (up to 6200 psi)
■
Improve gradient accuracy and increase sensitivity
■
Reduce baseline noise
■
In-line binary format
Description
Binary T Mixer
Binary T Mixer
In-Line Mixer Assembly
In-Line Mixer Assembly
Binary T Mixer Cartridge
Binary T Mixer Cartridge
Binary T Mixer Cartridge
Binary T Mixer Cartridge
Binary T Mixer Cartridge
Size
Part No.
10 μL
25 μL
150 μL
500 μL
10 μL
25 μL
50 μL
150 μL
250 μL
N2911170
N2911171
N2911173
N2911172
N2911174
N2911175
N2911176
N2911177
N2911178
Series 200 Dynamic Mixer
Series 200 Dynamic Mixer Accessory (100-240 V) – Used to facilitate
complete mobile phase blending, resulting in improved retention
performance. The mixer will most typically be used as part of a Series
200 Micro pump package – where high-pressure blending of 2 pump
outputs is required. Three different volume mixing heads (75, 200 and
400 μL) are available.
Kit includes: Mixer Accessory, Stainless Steel “Tee” Fitting (N2911127),
U.S. style AC Line Cord and 0.1 A Type T Fuse.
Part No.
N2910520
Mixing Heads
Mixing Head
Size
Part No.
75 μL
200 μL
400 μL
N2910521
N2910522
N2910523
Order online at www.perkinelmer.com/supplies
ORDER TODAY
25
supplies and accessories
Injection valves and rotor seals
for analytical HPLC
Rheodyne ™ 9725 PEEK
Bio Injection Valve
Flom Analytical Injection Valve
The Flom Analytical Injection Valve is a very reliable manual HPLC
injection valve. It comes with a built in “Inject” contact closure
connection output. A PEEK rotor seal is provided for excellent
solvent/sample resistance and the fluid path is designed for minimal
dispersion. This valve is available in either stainless steel or PEEK,
depending on the application or need.
Description
Part No.
Flom Injection Valve Stainless Steel
Flom Injection Valve PEEK
N9306073
N9306072
Injector Valve Rotor Seals
For both Series 200 Autosampler and manual injectors.
For both the Rheodyne and Flom valves, rotor seals should be periodically
replaced every 6 months to a year and are available in PEEK. For the
Rheodyne valve, they are also available in Vespel. PEEK is more inert
towards amines and other basic biomolecules/pharmaceuticals,
exhibiting less sample carryover. However, Vespel is somewhat
more resilient than PEEK, providing somewhat better wear life.
Description
Part No.
Flom Rotor Seal PEEK
Rheodyne 7725 Vespel Rotor Seal
Rheodyne 8125 Vespel Rotor Seal
Rheodyne 7725/9725 PEEK Rotor Seal
N9306068
09904802
10070900
N9306044
For a full listing of Rheodyne ™
injection valves, please visit:
www.perkinelmer.com/lcsupplies
26
Model 9725 is inert and well-suited to the chromatography of biological
molecules, including applications with aggressive mobile phases. This
valve is useful in all applications in which metal contact with the mobile
phase and or sample should be avoided. This valve uses PEEK vent lines
and a Teflon® rotor seal and can be operated in a pH range from 0 – 14.
Description
Part No.
9725 Injection Valve for Series 200 Autosampler
N9306020
Rheodyne ™ 8125 Low-Dispersion
Stainless Steel Injection Valve
Ideal for use in an LC/MS system, the model 8125 is designed for
1 and 2 mm microbore columns and can also be used with
conventional analytical (3 to 5 mm) columns. Small flow passages
produce low dispersion, maintaining the high mass sensitivity inherent
in micro columns.
Description
Part No.
8125 Low-Dispersion Stainless Steel Injection Valve
N9306021
Rheodyne ™ 7725 Analytical Injection Valve
Inject from 1 μL to 5 mL with high accuracy and precision,
with the Rheodyne™ 7725 and 7725i valves.
Rheodyne™ 7725 and 7725i valves are versatile injectors and can use
both partial-filling and complete-filling methods for loading the sample
loop. Wide port angles of the 7725/7725i valve provide improved
access to fittings. Sample loop with a 2 μL internal capacity is also
available. In a clean system, the 7725/7725i typically can make more
than 30,000 injections before requiring replacement of the rotor seal.
Description
Part No.
7725 Injection Valve for Series 200 Autosampler
7725i Injection Valve with Internal Switch
N9306019
N9306017
See page 2 for ordering information and a complete listing of PerkinElmer offices.
flow cells
Interchangeable flowcells
and pump accessory kits
Bio Conversion Kits
There are two kits available; one that contains all of the parts necessary
to convert the Series 200 pump and Series 200 autosampler for Bio
applications. The other contains all of the parts necessary to convert
only the Series 200 Pump for Bio applications.
Description
Part No.
S200 Pump and S200 Autosampler Conversion Kit
S200 Pump Conversion Kit
N2910035
N2910036
Pump Seal Kits
N2910384
These flowcells provide the highest detection limits possible for
your sample. The 6 mm pathlength flowcell has been optimized for
lower-dispersion LC analysis and is the perfect choice when using
narrowbore, 2.1 mm or microbore, 1 mm columns (see Figure 1).
The 3 mm pathlength is the choice for semiprep LC to avoid
detector saturation at high-solute concentrations.
N2910345
UVVis, PDA and LC-135/235 FLOWCELLS
Description
Part No.
High Pressure Piston Seal Replacement Kit
Includes: Seals (4), Backup Rings and O-Rings
Micropump Piston Seal Replacement Kit
Includes: Seals and O-Rings
Series 200 Pump Maintenance Kit
Includes: Fuses, Seals, O-Rings and Seal Tools
N2910383
Description
Detector Backpressure Regulator
The detector backpressure regulator is a device that is attached
to the outlet of the detector to prevent outgassing in the flowcell,
eliminating variations to the detector baseline.
Detector Backpressure Regulator
Description
40psi inline back pressure regulator
2 – 5K psi variable back pressure regulator
Backpressure Regulator
Adjustable from 15 – 59 psi
Flexar UVVis, Series 200/785A UV/VIS,
Flexar PDA and Series 200 EP
Material
Part No.
Stainless Steel
N2925090
N2925091
09907126
Part No.
Flowcells for Flexar FX-UV/Vis UHPLC Detectors
Flowcell
6 mm x 2.4 μL
Flowcell Kit (includes flowcell
6 mm x 2.4 μL
& detector head plate w/ gasket)
Flowcells for Flexar FX-UV/Vis UHPLC Detectors
Flowcell Assembly
(w/ heat exchanger and zdv unions)
10 mm x 15 μL
Flowcell
10 mm x 15 μL
Flowcell Assembly (w/ zdv unions)
6 mm x 2.4 μL
Prep Flowcell Assembly (w/ zdv unions) 3 mm x 1.7 μL
Prep Flowcell
3 mm x 1.7 μL
Flowcells for 785A UV/Vis Detectors
Flowcell
8 mm x 12 μL
Flowcell Assembly
8 mm x 12 μL
(w/ heat exchanger and zdv unions)
Flowcells for Flexar FX-PDA UHPLC and Series 275 PDA Detectors
Flowcell (dual-lensed)
6 mm x 2.4 μL
Flowcell Assembly (w/ mount)
6 mm x 2.4 μL
Flowcells for Flexar and Series 200EP PDA Detectors
Flowcell
10 mm x 15 μL
Flowcell Asembly
10 mm x 15 μL
Flowcells for Series 200 PDA Detectors
Flowcell
10 mm x 12 μL
Flowcell
4.5 mm x 5 μL
Flowcells for LC-135/235 PDA Detectors
Flowcell Assembly (w/ heat exchanger)
10 mm x 8 μL
Flowcell
10 mm x 8 μL
Order online at www.perkinelmer.com/supplies
N2920127
N2920070
N2920125
N2920124
29000544
29000545
29000573
29000542
N2920117
N2920128
N2920166
N2920126
N2920160
N2922107
N2922030
N2350211
N2350162
ORDER TODAY
27
detector lamps
For outstanding performance, use only
PerkinElmer deuterium, tungsten
or xenon HPLC lamps
UV/VIS Deuterium
Detector Lamp
Series 200/200 EP
Photo Diode Array Detector Lamp
Our extensive quality control and inspection process demands
the very best quality sources. Choosing a PerkinElmer deuterium,
tungsten or xenon source provides outstanding ultraviolet and
true visible performance.
■
Exceptional performance anywhere in the
detector’s 190 – 700 nm wavelength range
■
Lamp changes are quick and easy due to
a unique self-aligning lamp mount
Photo Diode Array Detector Lamps
The Flexar Series/Series 200/200 EP Photo Diode Array Detector provides true
UV/VIS detection and high resolution spectral data. The excellent signal-to-noise
characteristics make it ideally suited for low-volume or low concentration samples.
Flexar/Series 200 EP
UV/VIS Detector Lamps
Components
Part No.
Deuterium Lamp
Tungsten Lamp
N2925030
N2922011
Series 200
Flexar Series/Series 200/785A UV/VIS Detector Lamps
Components
Part No.
Deuterium Lamp
Tungsten Lamp
N2920149
N2920146
LC-295 UV/VIS Detector Lamps
Components
Part No.
Deuterium Lamp
02712266
Components
Part No.
Deuterium Lamp (Phase 2)
Tungsten Lamp
N2922046
N2922011
LC-135C/235
Components
Part No.
Detector Lamp
N2351285
Fluorescence Detector Lamps
Refractive Index Detector Lamps
The Flexar Series/Series 200/200s Refractive Index, with its deflection-type
design, allows sensitive detection of these compounds with low noise and
drift characteristics.
Series 200/200a
Components
Part No.
Tungsten Lamps
02712273
The major benefit afforded by fluorescence detection is the inherent high
sensitivity of the technique coupled with outstanding specificity. The Series 200a
Fluorescence Detector provides signal to noise ratio of >700:1 from trace
analysis using a 150 W xenon source.
Flexar/Series 200/200a
Components
Part No.
Xenon Lamp
N2922082
LC-240
For our complete listing of
HPLC detector lamps, please visit:
www.perkinelmer.com/lcsupplies
28
Components
Part No.
Xenon Lamp
Festoon Lamp
L2251157
04969486
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Nitrogen Generators
PerkinElmer offers customers a new line of nitrogen generators
to meet the growing need for cost effective and pure nitrogen.
Membrane Nitrogen Generators are designed to supply single
or multiple LC/MS instruments with dry nitrogen at purities of
98% to 99.5%.
The generator can also be used for solvent evaporation as well
as supplying dry nitrogen to analytical instruments.
Features and Benefits
■
LC/MS grade purity enhances instrument performance
■
Phthalate-free
■
Recommended, certified, tested, and used by all major
LC/MS instrument manufacturers
■
Return on investment in 6 months to 2 years
■
Minimal maintenance required
LC/MS
■
Solvent Evaporation
■
Analytical instruments
requiring nitrogen
■
Thermal Analyzers
Part No.
N9306210
Product Specification
Purity:
Atmospheric Dewpoint
Particles >0.01 μm:
Suspended liquids:
Min./Max. operating pressure:
Ambient operating temperature range:
Inlet air temperature range:
Maximum recommended inlet air temperature
Electrical requirements:
Dimensions (net):
Weigh (shipping):
95.0 – 99.5%
-58 °F (-50 °C)
None
None
60/145 psig (4.0/10 barg)
60 °F – 95 °F (15 °C – 35 °C)
60 °F – 95 °F (15 °C – 35 °C)
110 °F (43 °C)
None
45 cm W x 41 cm D x 130 cm H
36 kg, 80 lbs
Description
N2-35 Mid Flow Nitrogen Generator
without Air Compressor
Applications
■
Description
N2-22 Mid Flow Nitrogen Generator
without Air Compressor
Flow Rates*
Inlet
psi
100
125
100
125
100
125
Output Purity
Ipm
%
13
99.5
16
99.5
20
99.0
25
99.0
30
98.0
38
98.0
nitrogen generators
Liquid Chromatography/
Mass Spectrometry
Part No.
N9306211
Product Specifications
Low Flow NITROFLOW Lab
Features and Benefits
■
Complete “Plug and Play” system recommended by all
major LC/MS manufacturers
■
8,000 hours compressor warranty or two years
■
Special design ensures quiet operation
■
Dual oil-less air compressors
Components
120 V
230 V
Part No.
N9306213
N9306214
Product Specification
Purity:
Phthalate-free
Hydrocarbon-free
Flow Rates
Delivery pressure
Ambient temperature
Power consumption
Noise level
Electrical requirements
Lab capacity at nominal conditions:
Ambient temperature:
Ambient pressure:
Dimensions (net):
Weigh (shipping)
94.0 – 99.5%
10 – 50 lpm
8 bar
10 °C – 35 °C
1400 Watts
<58 dB (A)
120 V / 60 Hz, 20 Amp Nema 5
20 °C/ 68 °F
1013 mbar(a).
90 cm W x 31 cm D x 70 cm H
127.4 kg, 280 lbs
Purity:
Atmospheric Dewpoint
Particles >0.01 μm:
Suspended liquids:
Min./Max. operating pressure:
Ambient operating temperature range:
Inlet air temperature range:
Maximum recommended inlet air temperature
Electrical requirements:
Dimensions (net):
Weigh (shipping):
95.0 – 99.5%
-58 °F (-50 °C)
None
None
60/145 psig (4.0/10 barg)
60 °F – 95 °F (15 °C – 35 °C)
60 °F – 95 °F (15 °C – 35 °C)
110 °F (43 °C)
None
45 cm W x 41 cm D x 130 cm H
41 kg, 90 lbs
Description
N2-45 High Flow Nitrogen Generator
without Air Oiless Compressor
Flow Rates*
Inlet
psi
100
125
100
125
100
125
Output Purity
Ipm
%
20
99.5
25
99.5
30
99.0
37
99.0
46
98.0
57
98.0
Part No.
N9306212
Product Specifications
Purity:
Hydrocarbon free
Phthalate free
Atmospheric Dewpoint
Particles >0.01 μm:
Suspended liquids:
Min./Max. operating pressure:
Recommended ambient operating temp range
Inlet air temperature range:
Maximum recommended inlet air temperature
Inlet/Outlet ports
Electrical requirements:
Dimensions (net):
Weigh (shipping):
95.0 – 99.5%
-58 °F (-50 °C)
None
None
60/145 psig (4.0/10 barg)
72 °F (22 °C)
60 °F – 95 °F (15 °C – 35 °C)
110 °F (43 °C)
1/2” NPT
None (filtration system only)
61 cm W x 50 cm D x140 cm H
114 kg, 250 lbs
*See www.perkinelmer.com for complete listing of flow rates.
Order online at www.perkinelmer.com/supplies
Flow Rates*
Inlet
psi
100
125
100
125
100
125
Output Purity
Ipm
%
39
99.5
55
99.5
53
99.0
74
99.0
73
98.0
106
98.0
ORDER TODAY
29
c l a r u s 6 0 0 g a s c h r o m a t o g r a p h / S WA F E R
MICRO-CHANNEL
WAFER TECHNOLOGY
Redefining Your GC Pathway
PerkinElmer’s Swafer ™
PerkinElmer’s Swafer™ micro-channel wafer technology is an innovative
and user-friendly approach for flowswitching and splitting applications –
it delivers unparalleled hardware and application flexibility, expanding the
capabilities of capillary gas chromatography (GC).
Every fast-paced, high-volume laboratory
shares a common goal: to speed up
analytical cycle times. Now, PerkinElmer
delivers with its latest innovation in GC,
the high-performance Clarus ® 600
Gas Chromatograph.
Clarus 600 Gas Chromatograph –
the innovation is simply its speed
Powered by the fastest available heat-up
and cool-down conventional oven
PerkinElmer has always led the way with innovations in gas chromatography
and the Clarus 600 Gas Chromatograph (GC) is no exception. It features a
unique, high-performance oven with the fastest combined heat-up and
cool-down rate in a conventional GC oven design.
Autosampler pre-rinse performs time-consuming syringe rinse with sample
before the GC becomes ready, saving time in between runs. The resulting
shorter injection-to-injection time will significantly increase your throughput
and productivity by speeding up your analytical cycle time. And higher
productivity means a fast return on your investment (ROI).
QUICK GLANCE
30
SWAFER
The fastest
injection-to-injection
time
in conventional gas
chromatography
■
Oven cool-down from 450 °C to 50 °C in less than 2 minutes
■
Integrated autosampler adds flexibility and automation
■
Temperature programmable inlets deliver performance and
flexibility for more demanding applications
■
Programmable pneumatic control (PPC) adds automation efficiencies
■
Exclusive optional PreVent pressure-balanced system enhances
performance and productivity
■
Innovative, intuitive touch-screen interface makes operation
easy–no training required
■
Scalable TotalChrom CDS make data management and reporting
easier than ever
■
PerkinElmer’s complete offering allows easy integration of
best-in-class mass spectrometer, headspace, headspace
trap or thermal desorption
This exciting new technology can benefit most analytical laboratories.
From simple techniques such as connecting two detectors to one
column, and removing unwanted material from a column, to sophisticated
multidimensional separations on complex samples, Swafer’s capabilities
cover a wide range.
Key Benefits:
■
Allows you to tackle difficult or otherwise impossible separations,
delivering richer sample information which was previously unattainable
■
User-friendly design and user-defined oven position allow easy setup
and configuration changes, without requiring service intervention
■
Complete independence of the column from injectors or detectors lets
you combine injection techniques (headspace, thermal
desorption, liquid, etc.), based on sample requirements
■
15 user-interchangeable configurations deliver over 18 possible modes
of operation for unparalleled application flexibility
■
Can be used on any Clarus 500 or 600 GC with programmable
pneumatic control (PPC)
See what the Swafer can do for you – www.perkinelmer.com/swafer
Swafer Kits for New Clarus GC Systems
Description
Part No.
D-Swafer Complete Kit – for new Clarus
GC units only (for Clarus 600/500 GCs with PPC)
Includes all required installation hardware,
user guides, and the D-Swafer.
S-Swafer Complete Kit – for new Clarus
GC units only (for Clarus 600/500 GCs with PPC)
Includes all required installation hardware,
user guides, and the S-Swafer.
N6520273
N6520272
Swafer Kits and Accessories for
Existing Clarus GC Systems
Description
Part No.
Micro-Channel Kit for Existing Clarus 600/500 GC
(for Clarus 600/500 GCs with PPC)
Includes all hardware required to install a Swafer. The Swafer
and installation are not included and must be purchased separately.
Micro-Channel Kit for Existing Clarus 600/500 GC with
PreVent Currently Installed
If PreVent is already included in the GC configuration, this
hardware kit provides the additional parts required to install
a Swafer. The Swafer and installation are not included and
must be purchased separately.
D-Swafer Dean’s Switch (Swafer only)
S-Swafer Splitter (Swafer only)
N6520270
See page 2 for ordering information and a complete listing of PerkinElmer offices.
N6520271
N9306251
N9306262
Marathon
Filament for
PerkinElmer with
GC/MS Systems
Whatever you need it for the
Clarus 600 GC/MS family delivers
The compact Clarus 600 GC/MS, with its advanced electronics,
features the widest mass range and best-in-class detection limits
of any quadrupole MS. Our high-speed scanning delivers far better peak
integrity and accuracy. Its gas chromatograph has the fastest heat-up
and cool-down oven in a conventional GC. Multiple pumping options
offer an instrument for every lab’s needs. Plus, the system is driven by
our sample-centric TurboMass™ software for ease-of-use from data
collection to evaluation and reporting.
QUICK GLANCE
■
El and CI: best-in-class signal/noise specifications offer new
possibilities for analysis
■
Plug-and-play ion source: loosen two screws and easily change
when needed
■
Three pumping systems: provide the right performance to fit your
needs and budget
■
Smaller footprint: for economical space use
■
Fastest scan rates (12,500 amu/sec): for the most accurate
determination of peaks
■
Widest mass range (1 – 1,200 u): encompasses a variety of
applications, such as brominated flame retardants
■
SIFI™ simultaneous collection of selected ion and full ion
scanning data for the most productive analytical work
■
UltraTune™ automated tuning for BFB/DFTTP or custom
tuning on any compound for faster setup
A model for every lab’s needs:
Clarus 600 C GC/MS:
■
Electron ionization and chemical ionization with 255 L/sec turbomolecular pump
Clarus 600 T GC/MS:
■
The new Marathon™ Filament is a revolutionary,
patent-pending technology developed exclusively by
PerkinElmer, delivering long life even under the most
difficult chromatography conditions.
After lengthy performance testing and filament research, the new
Marathon Filament has been engineered to provide exceptional
long life and withstand difficult chromatography conditions.
It has high resistance to demanding injections such as headspace
or purge and trap and has stood up to challenging applications
such as flame-retardant analysis.
The Marathon Filament is a direct replacement of the previous
rhenium filament – no system changes required.
At PerkinElmer, we understand your challenges and are committed
to providing the best solutions to make your life easier – the new
Marathon Filament is part of our ongoing efforts to deliver the
latest technology for our PerkinElmer GC/MS platform.
Features and Benefits:
■
Long life even under the most difficult chromatography conditions
■
Unique white surface engineered for maximum durability and
optimum performance
■
Now included with all new Clarus® GC/MS systems
(560 and 600 series)
■
Backward compatible with all units using rhenium filaments
■
Works with both electron and chemical ionization sources
Description
Part No.
Marathon Filament for PerkinElmer GC/MS Systems
N6470012
clarus 600/560 gas chromatograph/Marathon Filament
Get results better
and faster with
the NEW Clarus
600/560 Family
of GC/MS
Electron ionization with 255 L/sec turbomolecular pump
Clarus 600/560 S GC/MS:
■
Electron ionization with 75 L/sec turbomolecular pump
Clarus 600/560 D GC/MS:
■
To view the webcast and to order
your replacement filament, visit:
www.perkinelmer.com/MarathonFilament
Electron ionization with air-cooled oil diffusion pump
Order online at www.perkinelmer.com/supplies
ORDER TODAY
31
Organic Standards from PerkinElmer GC and GC/MS
Organic Calibration Standards
For customer ease, all Organic Standards are prepared with a precision
of +/- 0.5% and accompanied with a comprehensive Certificate of
Analysis (lot specified by part number). Data packs are also available
upon request. These include a chromatogram of the standard and
quantitative report listing the values for each analyte.
Method 8260B for Water
and Solid Waste Matrices
PerkinElmer offers a wide selection of GC and GC/MS standards.
Each solution is supplied with a comprehensive Certificate of
Analysis that documents quality and assurance to the highest level
obtainable by a Calibration Standard.
Organic Certified Reference Materials from PerkinElmer are a new
addition to an already extensive organic product line, designed to
enhance your one-stop shopping experience. Each new standard is
provided in convenient 1.2 mL ampules to minimize waste and comes
with a pre-labeled amber glass storage vial with cap for easy use.
To ensure customer satisfaction, our Organic Mixes are prepared
at concentration levels that take into consideration a number of
factors including: vapor pressure, evaporation, breakdown rates and
dilution schemes. PerkinElmer goes the extra step by analyzing each
organic standard on the Clarus 600 GC and GC/MS state-of-the-art
instrumentation, to ensure that the standard conforms to the
customer’s exact needs.
600 Series Wastewater Methods
Clean Water Act “Wastewaters”
Interferene
Volatile
Organics
CheckCombination
Standards Blend
Contains all analytes in Mixes A, C and D.
Method SW-846 is an analytical method which utilizes a Clarus 600 GC to
perform the separation of the volatile organic components found in a variety
of solid waste matrices. To detect the GC eluant a Clarus 600 GC/MS is used.
Description
Part No.
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331047
Description
Contains: N9331060, N9331061, N9331062, 9331063.
Description
Part No.
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331064
Mix A for Method 624
N9331060
Purgeable Gases Mix B for Method 624
Part No.
Alternate Four-Component Surrogate Standard for Method 8260B
1.2 mL @ 2,000 μg/mL in P & T Methanol
The U.S. EPA Method 624 is an analytical method which utilizes a TurboMatrix
Headspace Purge and Trap instrument for sample prep and a Clarus 600 GC
equipped with a packed column to perform the separation of the volatile organic
compounds found in a 5 mL sample of municipal or industrial wastewater. To
detect the eluant a Clarus 60 GC/MS is used.
1.2 mL @ 2,000 μg/mL in P & T Methanol
Method 524.2 is an analytical method that uses a purge and trap device
for sample preparation and a GC/MS equipped with a capillary column
to perform the separation of volatile organic compounds.
Interferene
Method
8260B
Check
Standards
Standards
Method 624 Standards Kit for Volatile Organic Compounds
1.2 mL @ 2,000 μg/mL in P & T Methanol
Method 8260B is an analytical method that uses a GC/MS equipped
with a capillary column to perform the separation of the volatile organic
compounds found in water and a variety of solid waste matrices.
N9331042
Internal Standard for Method 8260B
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331041
Interferene
Ketones
for Check
MethodStandards
8260B
Description
Part No.
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331043
N9331061
Mix C for Method 624
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331062
Mix D for Method 624
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331063
For a full product listing of NEW
PerkinElmer GC Standards please visit:
www.perkinelmer.com/gcsupplies
32
Mix B Purgeable
Interferene
CheckGases
Standards
for Methods 8260B/524.2
Description
Part No.
1.2 mL @ 2,000 μg/mL in P & T Methanol
N9331048
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Merlin MicroSeal™
and SilTite™ ferrules
Merlin MicroSeal ™ Septum
The Merlin MicroSeal™ septa is a unique replacement
septa employing a two-step sealing system and an advanced
elastomer material.
SilTite™ metal ferrules provide a continuous leak-free connection
and are perfect for connecting your column to a GC/MS.
The SilTite™ metal ferrule and nut are manufactured from the same
material and therefore expand and contract at the same rate, eliminating
the need to retighten, even after temperature cycling. The base of the
SilTite™ ferrule forms a perfect seal with the MS interface, ensuring a
leak-free connection. SilTite™ metal ferrules have a temperature limit well
above the temperature capacity of the injector, MS interface or GC oven.
Description
Hole Size
SilTite™ Ferrules Starter Kit (pkg. 10)
SilTite™ Ferrules Starter Kit (pkg. 10)
SilTite™ Ferrules Starter Kit (pkg. 10)
SilTite™ Ferrules (pkg. 10)
SilTite™ Ferrules (pkg. 10)
SilTite™ Ferrules (pkg. 10)
SilTite™ Nuts (pkg. 5)
0.4 mm
0.5 mm
0.8 mm
0.4 mm
0.5 mm
0.8 mm
Part No.
N9306090
N9306091
N9306092
N9306093
N9306094
N9306095
N9306096
Capillary Column Ferrules
Graphite
Ferrule of choice for high-temperature applications up to 450 °C.
Graphite seals easily and does not stick to glass columns.
Because the syringe needle does not pierce the septa, there is no
debris and ghost peaks are greatly reduced. The MicroSeal™ septa also
reduces the incidence of bent syringe needles and liner contamination.
Usable in either manual or autosampler applications, this septa can
improve your productivity and run reliability. Designed to be used with
23 gauge straight needle syringes. Pressure ranges from 4 to 100 psi
and injection port temperatures up to 325 °C.
Features and Benefits
■
Thousands of injections before septa change
■
2-step sealing system
■
No debris — no ghost peaks
■
Temperatures up to 325 °C
■
Pressure ranges 4 to 100 psi
Description
Pkg.
Merlin MicroSeal™ Septum Kit
Includes: Injector Port Adapter,
2 Septa and 1 Nut
Merlin MicroSeal™ Septum
Part No.
N9303344
1
N9303345
Injector Septa
■
15% graphite/85% polyimide ferrule recommended for use with GC/MS
systems. Temperature limit 350 °C.
Thermogreen® LB-2 septum, extremely low bleed over a wide range of inlet
temperatures — 100 to 350 °C. Easier needle penetration and high puncture
tolerance make this septum ideal for autosamplers. This septum is already
conditioned and ready to use
■
BTO™ (Bleed Temperature Optimized) injector septa, 11 mm diameter.
Maximum recommended operating temperature 300 °C
Vespel®
■
PTFE/Silicone injector septa, 11 mm diameter
Graphite/Vespel®
Not reusable. Not recommended for fused silica capillary columns.
Use these ferrules on 1⁄16 inch metal tubing and glass-lined receivers.
Temperature limit 350 °C.
Capillary Column Ferrules
Nut
Size
Column i.d. / Ferrule i.d.
Graphite
Part No.
⁄16 in
1
⁄16 in
1
⁄16 in
1
⁄16 in
1
⁄8 in
1
⁄8 in
1
⁄8 in
0.18 – 0.25 mm / 0.4 mm
0.18 – 0.32 mm / 0.5 mm
0.18 – 0.32 mm / 0.5 mm*
0.18 – 0.53 mm / 0.8 mm
0.18 – 0.53 mm / 1.0 mm
0.18 – 0.32 mm / 0.5 mm*
0.18 – 0.32 mm / 0.5 mm
09903700
N9306001
09920141
09903394
09903395
09903981
1
*2-hole
Graphite/Vespel®
Part No.
09920104
09920105
N9306000
09920107
Description
Pkg.
Part No.
50
N6621028
Thermogreen Injector Septa
Low Bleed Injector Septa
25
N9303343
PTFE/Silicone Injector Septa
50
00090652
Green Injection Port Septa
10
N9306218
Green Injection Port Septa
50
N9306219
Orange Injection Port Septa
50
N9302972
Green Septa Rated to 400 °C The Advanced Green Septum was created to
combine significantly longer injection life, low bleed and low injection port
adhesion. The result is a general use green septum made of uniquely formulated
silicone rubber you can use for all your daily analyses. Packaged in a pre-cleaned
glass screw top jar for high purity.
Orange Septa Rated to 400 °C Uniquely Formulated Silicone Rubber Septa BTO®
is Bleed and Temperature Optimized for today’s most demanding GC and GC/MS
applications. Septa BTO® is formulated to extend low-bleed and outstanding
mechanical properties of premium GC septa. It retains remarkable softness at high
temperatures and has been optimized to reduce injection port adhesion. Packaged
in a precleaned glass screw top jar for high purity.
®
Order online at www.perkinelmer.com/supplies
ORDER TODAY
33
Inline Gas Purifiers for Clarus GC and
Fast and easy to use Click-On
Inline Super Clean™ Gas Purifiers
save you time and money
PerkinElmer Click-On Inline Super
Clean ™ Purifiers reduce your
maintenance system downtime
Using the Click-On Connectors lets you change the trap without
introducing contaminant’s into your system. Click-On connectors
can replace a trap, without introducing impurities into the system.
This in turn eliminates the need to flush the system.
The unique Click-On Connector fitting has a spring-loaded needle
valve, which seals when a trap is removed and only opens when a
new trap is connected and locked into position. When the Click-On
connectors are installed into the gas line, there is no need to loosen
or tighten any fittings, simply click on the new trap in seconds.
The ability to add a Click-On Inline Super Clean™ Indicator after the
stainless steel trap gives the user a clear visual indication of when to
change the filter. This indicator may also be used as a standalone trap.
Click-On Inline Purifier Compatibility Chart
Type of Gas
Reduce system downtime with Click-On fast connectors
■
High purity ensures 99.9999% pure gas
■
No open gas line when changing the trap
■
Helium Specific Glass Indicating Triple Trap is ideal for GC/MS
■
No tools necessary to replace trap
Oxygen
Filter
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Acetylene
Air
Carbon Dioxide
Helium
Hydrogen
Methane
Nitrogen
Nitrous Oxide
Oxygen
Propane
P5
Features and Benefits
■
Moisture
Filter
Hydrocarbons Combination
Filter
Filter
√
√
√
√
√
√
√
√
√
√
√
√
Triple
Filter
√
√
√
√
√
√
√
√
(5% Methane in Argon)
P10
(10% Methane in Argon)
Product Specifications
Purifier Type
Gas Quality*
Max. Pressure
Max. Flow
Use For
H20
Moisture
99.9999%
11 bar, 160 psi
25 L/min
Inert carrier gas
He, Air, H2
21 g
Capacity O2
NA
Hydrocarbons
> 3 years
NA
> 3 years
Oxygen
99.9999%
11 bar, 160 psi
25 L/min
Inert carrier gas
NA
3,000 mL
Hydrocarbons
99.9999%
11 bar, 160 psi
25 L/min
Inert carrier gas
Air, H2
NA
NA
36 g (as n-butane)
> 3 years
Combination Moisture/
Hydrocarbons
99.9999%
11 bar, 160 psi
25 L/min
Inert carrier gas
He, Air, H2
10 g
NA
18 g (as n-butane)
> 2 years
Indicating Triple Moisture/
Oxygen/Hydrocarbons
99.9999%
11 bar, 160 psi
25 L/min
Inert carrier gas
He
3g
400 mL
5 g (as n-butane)
> 1 year
Triple Moisture/
Oxygen/Hydrocarbons
99.9999%
11 bar, 160 psi
25 L/min
Inert carrier gas
6g
1,000 mL
12 g (as n-butane)
> 2 years
*Results @ 2 L/min
34
Est. Lifetime
NA
See page 2 for ordering information and a complete listing of PerkinElmer offices.
GC/MS
3-Cartridge Gas
Purification System
Stainless Steel Trap Kits
Description
Connector (Qty)
Part No.
Combination: Oxygen/Moisture Trap
Combination: Oxygen/Moisture Trap
Combination: Moisture/Hydrocarbons Trap
Combination: Moisture/Hydrocarbons Trap
Triple: Oxygen/Moisture/Hydrocarbons Trap
Triple: Oxygen/Moisture/Hydrocarbons Trap
Triple Gas Specific (He):
Oxygen/Moisture/Hydrocarbons
Triple Gas Specific (He):
Oxygen/Moisture/Hydrocarbons
1
⁄8" Brass (2)
1
⁄8" SS (2)
1
⁄8" Brass (2)
1
⁄8" SS (2)
1
⁄8" Brass (2)
1
⁄8" SS (2)
1
⁄8" Brass (2)
N9306108
N9306109
N9306117
N9306118
N9306110
N9306111
N9306112
⁄8" SS (2)
N9306113
1
Stainless Steel Traps
Description
Part No.
Moisture Trap
Oxygen Trap
Hydrocarbons Trap
Combination: Oxygen/Moisture Trap
Combination: Moisture/Hydrocarbons Trap
Triple: Oxygen/Moisture/Hydrocarbons Trap
Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons
N9306100
N9306101
N9306102
N9306103
N9306105
N9306104
N9306106
Helium Specific Glass Indicating Triple
Trap for your PerkinElmer Clarus GC/MS
PerkinElmer recommends the use of the Helium Specific Glass
Indicating Triple Trap for your GC/MS system. This trap contains
oxygen, moisture and hydrocarbons adsorbents in one trap and is
packed and purged under helium.
The glass indicating trap clearly shows when the filter needs to be
replaced with the use of color changes. The packing material is a
silica-based environmentally friendly substitute for cobalt dioxide (blue)
in the moisture indicator.
Available as a kit with the necessary 1⁄8" brass connectors, and as a
replacement trap, this system is easy to install.
Description
Connector (Qty)
Indicating Glass Triple Gas Specific (He):
Oxygen/Moisture/Hydrocarbons
Indicating Glass Triple Gas Specific (He):
Oxygen/Moisture/Hydrocarbons
Indicating Glass Triple Gas Specific (He):
Oxygen/Moisture/Hydrocarbons
Part No.
N9306107
⁄8" Brass (2)*
N9306114
⁄8" SS (2)
N9306116
1
1
AFS Manifold
and Mounting Hardware
Advanced Filter System
The Advanced Filter System has high capacity and
efficiency levels for oxygen, water and hydrocarbons.
The recommended maximum flow rate is 2.0 L/min
and 200 psi maximum operating pressure.
Features and Benefits
Advanced
Filter System
■
Two indicators, for oxygen and moisture
■
Easy cartridge replacement with on/off knob
■
Double seal construction for safety
■
Check valves protect gas lines during cartridge replacement
System
Capacity
Efficiency
Oxygen
Water
Hydrocarbns
850 cc
12 g
8g
< 1 ppb
< 10 ppb
< 1 ppb
A polycarbonate shield surrounds the glass indicator section of the filter
is sealed, unlike other gas filters, the gas flow is secure even if the glass
should break. This redundant sealing system and robust construction
provides a new level of security in gas filtration. Maximum flow rate is
2.0 L/min with 200 psi max operating pressure.
Description
Part No.
Advanced Filter System (manifold and mounting hardware included)
Replacement Cartridge
Manifold and Mounting Hardware
N9303963
N9303964
N9306139
3-Cartridge Gas Purification System
This system provides for high capacity contaminant removal for GC
supply gasses, and allows for individual cartridge replacement.
Cartridge replacement is recommended after processing 19 cylinders
of 8 m3 high purity gas (99.997%).
Features and Benefits
Special Saving Offers
from PerkinElmer!
Please contact your local PERKINELMER
sales office for additional details
■
All stainless steel cartridges are easy to replace
■
High capacity
■
Wall bracket gets the system up and out of the way
System
Capacity
Efficiency
Oxygen
Water
Hydrocarbons (C5 and higher)
1,000 cc
25 g
19 g
< 1 ppb
< 30 ppb
< 1 ppb
Description
Part No.
Purification System, 3 Head All Steel System
Cartridge Set, Gas Purification All System Cart (Replacement)
Cartridge, Gas Purification Moisture
Cartridge, Gas Purification Hydrocarbon
Cartridge, High Capacity O2 Replacement
Hardware, Gas Purification Manifold/Mtg
Hardware, Gas Purification Manifold/Mtg for bench or wall
N9306135
N9306136
N9306137
N9306138
N9306004
N9306140
N9306014
Order online at www.perkinelmer.com/supplies
ORDER TODAY
35
gc supplies
Essential GC lab
supplies from PerkinElmer
MiniTemp MT4 Non-contact
Temperature Measurement
with Laser Sighting
Features and Benefits
Portable Gas Leak Detector
The new PerkinElmer compact handheld electronic gas leak detector is
the ideal solution for detecting gas leaks in your Gas Chromatography
systems. Leaks in your system waste gas and can cause detector
noise, baseline instability, and shorter column life. This portable unit
detects minute leaks of any gas with thermal conductivity different from
air. The reference gas inlet draws in ambient air for comparison to air
drawn into the sample probe. A leak is detected by both LED bar graph
display and audible alarm.
■
Displays thermal measurement readings
in °C or °F
■
Easy point and shot infrared technology
in a pocket size configuration
■
Great for instrument thermal test
confirmation, including GC injector
port and detector measurements,
thermostatted LC vials, and
enzymatic hydrolysis baths
Non-contact Surface Temperature
Measurement with Laser Sighting
Specifications
Model
MiniTemp MT4
Temperature Range
-18 to 400 °C
(0 to 750 °F)
Distance to Spot Size (D:S)
8:1
Response time
500 m/sec
Detectable Gases
Gas
Type
Minimum Detectable
Leak Rate (atm cc / sec)
Helium
Hydrogen**
Nitrogen
Argon
Carbon Dioxide
1.0 x 10-5
1.0 x 10-5
1.4 x 10-3
1.0 x 10-4
1.0 x 10-4
Indicating LED
Light Color
Red
Red
Yellow
Yellow
Yellow
Battery: Rechargeable Ni-MH internal battery pack (6 hours normal
operation)
Universal Power Adapter Set: US, UK, European, Australian plugs
included
Operating Temperature Range: 32 – 120 °F (0 – 48 °C)
Humidity Range: 0 – 97%
Warranty: 1 Year
Certifications: CE, Japan
Compliance: WEEE, ROHS
Features and Benefits
■
Sleek ergonomic, hand-held design with rugged side grips
■
Automatic shut-off capabilities
■
Optimized sample flow path
■
LED readout and audible alarm
Pre-set at 0.95
Accuracy
±2%, or ±2°C (±3 °F)
whichever is greater
Typical Distance to Target (Spot)
Up to 1.5 m (4 ft)
Laser Sighting
Yes
The popular MiniTemp MT4 also includes single dot laser sighting to assist with aiming.
9 volt battery included. Recalibration is not available.
Description
Part No.
MiniTemp MT4
N9306074
Basic Tool Kit
Description
Part No.
Tools come in a tool box for easy storage and use
N9301327
Kit Includes:
Open-end Wrench Set (6 pc), Screwdriver Set (6 pc.), Adjustable Wrench (6 in), Chain
Nose Pliers (narrow), Wire Cutters, and Wire Strippers
Deluxe Tool Kit
Description
Part No.
Portable Electronic Leak Detector
Soft Carrying Case
Probe (fine tip)
N9306089
N9306142
N9306063
**Caution: The PerkinElmer leak detector is not designed for determining leaks in a combustible
environment. This unit may be used for determining trace amounts of hydrogen in a GC
environment only.
36
Emissivity
Description
Part No.
Shipped in a plastic tool box for convenient storage
N9301328
Kit Includes:
Open-end Wrench Set (6 pc.), Screwdriver Set (6 pc.), Adjustable Wrench (6 in), Chain
Nose Pliers (narrow), Wire Cutters, Wire Strippers, Slip-joint Pliers (6 in), Long Nose
No. 5 Stainless Steel Tweezers (43⁄8 inches), Needle File Set (6 pc.), Allen Key Set (11 pc.
imperial sizes), and Allen Key Set (9 pc. metric sizes)
See page 2 for ordering information and a complete listing of PerkinElmer offices.
flow meters
Flow Meters
Digital Bubble Flow Meter
The PerkinElmer Model 520 is a volumetric flow meter. It can
measure the flow rate of any gas or combination of gases, such as
air, without adjustment. The flow meter has a digital display and a
single push-button input. It is made of stainless steel
and anodized aluminum. It comes with a
certificate of calibration, and is accurate
to +/- 3%. The Model 520 can measure
flow rates of 0.5 to 500 mL/min.
Features and Benefits
■
0.5 to 500 mL/min flow rate
■
Digital Display
■
Volumetric flow measurement
■
9 V battery operation (included)
■
Digital Display
■
Accurate to +/- 3% of measured flow rate
Description
Part No.
Digital Bubble Flow Meter
Replacement Glass for Digital Bubble Flow Meter
N9302974
N9033429
PerkinElmer Electronic
Flowmeter 1000
The PerkinElmer Flowmeter 1000 allows for rapid real-time flow measurements. Flow rates measured in mL/min. (volumetric flow). The PerkinElmer
Flowmeter 1000 can quickly calculate split ratios. Ratios are displayed in
real time. Flowmeter not compatible with corrosive or flammable gases.
Portable operation. (9V battery included).
Features and Benefits
PerkinElmer FlowMark ™
Electronic Flowmeter
PerkinElmer’s FlowMark™ flowmeter is specifically designed for use
with gas chromatography (GC) instruments. The probe is applied
directly to the gas flow stream and the measured flow rate is
presented on the LCD screen. Units of flow are measured in mL/min.
This unit provides continuous real-time measurements of gas
streams ranging from 0.50 mL/min to 500 mL/min. Because the
technology uses volumetric flow measurement, the unit is
compatible with all laboratory gases. The flowmeter is designed to
measure clean, dry, non-corrosive gases.
Features and Benefits
■
Measures volumetric flow for all gases across
a range of 0.5 – 500 mL/min.
Operating Temperature 0 to 45 °C
■
NIST traceable calibrationy
Traceable to NST Primary Standard
■
Explosion-proof rating for flammable and explosive gases
■
Split Ratio Mode
■
Accuracy of ± 2% of flow or ± 0.05 mL/min., whichever is greater
■
Accuracy +/- 3%
■
Over range indicator
■
LCD Alphanumeric Display
■
Auto shut-off feature
■
Ergonomic design and side grips for comfort
■
Measures most gas types
■
Convenient storage case included
■
CE, Ex (Compliance:WEEE, RoHS) certified
■
Uses 2-AA batteries
■
Data output via USB port
■
Re-calibration service available
■
Operating Temp. Range: 32 – 120 °F (0 – 48 °C)
■
1 year warranty
■
Flow range 0.1 – 1000mL/min.
■
■
Description
Part No.
PerkinElmer Electronic Flowmeter 1000
N9307029
Soap Bubble Flow Meters
The glass soap bubble flow meters are calibrated in 1 and 10 mL two-stage
or 1, 10 and 100 mL three-stage for easy flow reading. Bubble meters come
complete with liquid soap, rubber squeeze bulb, miscellaneous-sized plastic
tube pieces to adapt to various fittings, and instructions (stand required, but
not included – N9303314).
Description
Part No.
Two-stage
Three-stage
Stand
00230522
N9300081
N9303314
Description
Part No.
FlowMark Electronic Flowmeter
Soft Carrying Case
N9307086
N9306142
™
Order online at www.perkinelmer.com/supplies
ORDER TODAY
37
syringes
GC injector and
autosampler syringes
New Blue Barrel color design for enhanced
sample volume verification (packs of 5 and 10 syringes)
Point Style 2
This is a general purpose point style
designed for septum penetration in all
chromatographic techniques. The needle
has a 22° bevel to minimize coring and
needle plugging.
Autosampler Syringes
Syringes from PerkinElmer are individually inspected for accuracy
and performance.
Recommended autosampler syringes are available in 0.5, 5 and 50 μL
capacities. For routine analyses, the metal plunger in barrel with
PTFE-tipped seal is the standard syringe as shipped with each Clarus®
GC instrument. Alternative syringes to use are the metal plunger in
barrel or the 0.53 mm on-column injection.
Description
Part No.
50 μL Syringe, Metal Plunger 0.63 mm o.d. needle
5 μL Syringe, Metal Plunger PTFE-tipped Seal
0.63 mm o.d. needle
5 μL Syringe, Metal Plunger PTFE-tipped Seal
0.63 mm o.d. needle BLUE Barrel (pack of 5 syringes)
5 μL Syringe, Metal Plunger PTFE-tipped Seal
0.63 mm o.d. needle BLUE Barrel (pack of 10 syringes)
5 μL Syringe, Metal Plunger 0.63 mm o.d needle
5 μL On-column Syringe Metal Plunger
0.47 mm o.d needle
0.5 μL Low Injection Volume Syringe,
Metal Plunger 0.63 mm o.d. needle
0.5 μL Low Injection Volume Syringe
Metal Plunger 0.63 mm o.d. needle BLUE Barrel (pack of 5 syringes)
0.5 μL Low Injection Volume Syringe
Metal Plunger 0.63 mm o.d. needle BLUE Barrel (pack of 10 syringes)
0.5 μL Low Injection Volume Syringe,
Metal Plunger 0.47 mm o.d. needle
N6101760
N6101390
†
38
25
22
26†
25
1
1
1
1
Recommended for PerkinElmer wide-bore capillary adapter
■
A 7 cm needle is critical to be sure your sample is deposited in the optimal zone
Syringe
Capacity
N6101252
10 μL
25 μL
50 μL
100 μL
N6103242
N6103243
N6101253
Point
Style
Gauge
Length
Pack
Size
Point
Style
1
1
1
1
#2
#2
#2
#2
Part No.
N9302210
N9302211
N9302212
N9302213
Replacement Needles for RN Syringes
Syringe
Capacity
10 μL
25/50/100 μL
250 μL
Syringes come standard with needle length of 7 cm — optimum for
PerkinElmer injectors
0.5 μL
1.0 μL
1.0 μL
2.0 μL
All PerkinElmer injectors have been tested and optimized for use with a
7 cm needle
Removable Needle Syringes (RN)
■
Pack
Size
■
N6101251
N6101380
Recommended for liquid sample injections of less than 5 μL for
gas chromatography
Length
GC Injector Syringes
N6103241
Ultramicro Volume Syringes
Gauge
Needle has a 90° bevel. Point style is
recommended when the syringe is used
for accurate pipetting of liquids. Excellent
for mixing standards of very small volume.
N6103240
■
Syringe
Capacity
Point Style 3
Gauge
Length
Pack
Size
Point
Style
26S
22S
22S
2 in
2 in
2 in
3
3
3
#2
#2
#2
Length
Pack
Size
Point
Style
1
6
1
1
1
1
#2
#2
#2
#3
#2
#3
Part No.
N9302222
N9302224
N9302226
Fixed Needle Syringes
Part No.
N9302231
00230177
00230111
N9302235
Syringe
Capacity
10 μL**
10 μL*
25 μL
25 μL
50 μL
50 μL
Gauge
*Savings based on one-piece price. Savings of 20% reflected in price shown.
**Standard fitted with 7 cm needle.
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Part No.
00230523
N9302230
N9302202
09904823
N9302203
09904941
Programmed Temperature Split/Splitless (PSS) Injector Liners
Dimensions (mm)
i.d. x o.d. x length
Description
Pkg.
Part No.
Quartz Split Liner
PerkinElmer Standard (ships in instrument)
2 x 4 x 86.2
1
N6121004
Quartz Split Liner with Silanized Glass Wool
2 x 4 x 86.2
1
N6121008
Quartz Split Liner with Silanized Glass Wool
2 x 4 x 86.2
5
N6121009
Quartz Splitless Liner
Excellent for low-volume analysis (ships with instrument)
1 x 4 x 86.2
1
N6121006
2.4 x 4 x 86.2
1
N6101539
2 x 4 x 86.2
5
N9302949
On-Column Glass Liner
Borosilicate Glass Split Liner
This liner is loosely packed with wool for the specific use of analyzing fuel in oil
glass inlet liners
Glass Inlet Liners
for PerkinElmer Injector Systems
Capillary Split/Splitless Injector Liners
Dimensions (mm)
i.d. x o.d. x length
Description
Pkg.
Part No.
Quartz Liner for Split Operation
Good for large volume injections
4 x 6.2 x 92.1
1
N6121001
Quartz Liner for Split Operations with Silanized Glass Wool
Good for large volume injection
4 x 6.2 x 92.1
1
N6121010
Quartz Liner for Split Operations with Silanized Glass Wool
Good for large volume injection
4 x 6.2 x 92.1
5
N6121011
Quartz Liner for Splitless Operation
Standard Injector Liner (ships with instrument)
2 x 6.2 x 92.1
1
N6121002
Glass Liner for Split Operation
Universal liner for general purpose analysis
4 x 6.2 x 92.1
1
N6101052
Glass Liner for Splitless Operation
Universal liner for general purpose analysis
2 x 6.2 x 92.1
1
N6101372
Precision Split Glass Liner Deactivated Surface with wool
Wool can be adsorptive if fibers are broken
4 x 6.2 x 92.1
5
N6121020
Zero Dilution Glass Outer Liner
Ideal for trace headspace work
2.7 x 6.3 x 69
1
N1011445
1 x 2 x 73
1
N1011446
Zero Dilution Inner Liner
Use with Outer Liner (N1011445)
Packed Column Injector Liners
Dimensions (mm)
i.d. x o.d. x length
Description
Wide-Bore Column On/Off Quartz Liner
Wide-Bore Column Glass Liner
6 x 4 x 92.1
Pkg.
Part No.
1
N6121003
6 x 4 x 92.1
1
N6101375
Drilled Uniliner (hole on bottom) NEW!
Good for PPC equipped GCs. Recommended for analysis in which
compounds of interest could be affected by a tailing solvent peak.
4 x 6.2 x 92.1
5
N6502013
Gooseneck Drilled Uniliner (hole on top) NEW!
Use for trace, active samples. Gives high recovery and linearity.
4 x 6.2 x 92.1
5
N6502014
Order online at www.perkinelmer.com/supplies
ORDER TODAY
39
Autosamplers Vials, Caps and Septa
Vials, Caps and Septa Kits
from PerkinElmer
PerkinElmer Supplies –
Tested and Approved
We have expanded our product selection to cover additional test
applications and to make it easier for our customers to order
prepackaged kits for their daily production requirements. Tested to meet
your application requirements and guaranteed for fit and compatibility.
AutosamplerCheck
Interferene
CrimpStandards
and Screw
Top Vials, Caps and Septa (continued)
Description
Autosampler Crimp and Screw
Top Vials, Caps and Septa
Our screw thread vials are custom designed for PerkinElmer Clarus GCs.
Manufactured from Type 33 borosilicate glass, the vials have high-temperature
tolerance and are chemically inert. Color variety crimp caps offer easy identification
within the laboratory on 2 mL crimp top vials. Microsampling with a maximum
capacity of 200 L can be accomplished with the use of a low-volume insert and
support foot.
®
Description
Pkg.
Part No.
CRIMP TOP VIALS:
(also see Convenience Kits for Additional Vials and Caps Sold Separately)
2 mL 11 mm Crimp Top Clear Glass Vials
2 mL 11 mm Crimp Top Amber Glass Vials
®
®
®
®
®
40
200-μL Low-Volume Clear Glass Insert
Vial Support for Insert
09923032
09923031
N9306247
N9302780
N6101276
1000
500
N9302681
N9302682
100
N9300703
1 each
N9300704
Use with:
10 mm 2 mL Amber Screw Top Vial w/ White “P’ Icon w/ Patch
10 mm 2 mL Clear Screw Top Vial w/ White “P” Icon w/ Patch
11 mm Clear Large Opening Snap Ring Vial w/ Black “P” Icon
11 mm Clear Large Opening Crimp Vial w/ Black “P” Icon
9 mm 2 mL Amber Screw Top Vial w/ Black “P” Icon
9 mm 2 mL Clear Screw Top Vial w/ Black “P” Icon
N9306057
N9306053
N9303418
N9306231
N9306220
N9306201
LOW VOLUME VIAL GLASS INSERTS:
100
100
100
100
1000
N9302686
N9302684
N9302685
N9306015
N9302784
100
100
100
100
100
N9302945
N9303441
N9306201
N9306220
N9303442
100
100
N9303418
N9306207
100
N9306208
VIAL HOLDER RACKS:
100
100
100
N9303416
N9303417
N9303419
36-Vial Capacity 20 mm Vial Holder Rack
50-Vial Capacity 11 mm Vial Holder Rack
SNAP TOP VIALS/CAPS/SEPTA:
2 mL 11 mm Clear Snap Wide Opening Vials
2 mL 11 mm Clear Snap Wide Opening Vials
with Write-On Patch and Fill Lines
2 mL 11 mm Amber Snap Wide Opening Vials
with Write-On Patch and Fill Lines
11 mm Pre-slit PTFE/Silicone Snap Caps
11 mm Pre-slit PTFE/Silicone/PTFE Snap Caps
11 mm PTFE/Silicone Snap Caps
Part No.
INSERTS:
N9301385
N9302680
SCREW TOP VIALS/CAPS/SEPTA:
2 mL 8 mm Screw Top Clear Glass Vials
8 mm Screw Caps
2 mL 9 mm Screw Top Clear Vials
2 mL 9 mm Screw Top Amber Vials
PTFE-Coated Butyl Rubber Septa for 8 mm Screw Top Vials
Cap for Waste and Wash Vials (15 mm)
1 each
Clear Waste and Wash Vial 4 mL (15 mm)
1 each
Clear Waste and Wash Vial 4 mL (15 mm)
100
Septa for Waste Wash Vials (for use with
50
Viscous or Toxic Samples)
Diffusers for Waste and Wash Vials
1
Diffusers are sold exclusively by PerkinElmer. The conical
shape allows theneedle to penetrate into solvent or waste.
Reduces spillage and large losses through evaporation.
100
100
CRIMP TOP SEPTA:
11 mm Blue Crimp Caps with Teflon Rubber Septa
11 mm Green Crimp Caps with Teflon Rubber Septa
11 mm Red Crimp Caps with Teflon Rubber Septa
11 mm Silver Crimp Caps with Teflon Rubber Septa
11 mm Silver Crimp Caps with Black Viton Septa
Pkg.
WASTE AND WASH VIALS/CAPS:
6 mm x 29 mm Clear Glass Insert, Rimless Pulled
Point with Bottom Spring, 250 μL Usable Volume
6 mm x 31 mm Clear Glass Flat Bottom Insert,
400 μL Usable Volume
5 mm x 29 mm Clear Glass Insert Rimless Pulled Point
with Bottom Spring, 250 μL Usable Volume
5 mm x 31 mm Clear Glass Flat Bottom Insert,
200 μL Usable Volume
100
N9300705
100
N9300706
Use with:
11 mm Standard Amber Crimp Vial w/ Black “P” Icon
11 mm Standard Clear Crimp Vial w/ Black “P” Icon
8 mm 2 mL Clear Screw Top Vial w/ Black “P” Icon
N9302680
N9301385
N9302945
1
1
See New Convenience Kits for Additional Vials, Caps and Septa
See page 2 for ordering information and a complete listing of PerkinElmer offices.
N9301304
N9301303
Kits
Crimping
Tools
and Kits
Crimping Tools
Whatever your need may be, PerkinElmer offers a wide range of crimping tools for
your convenience. Our universal voltage, precision control, power crimpers with
adjustable settings are designed to deliver hundreds of crimps on a single
battery charge.
Description
Pkg.
Part No.
1
1
1
1
1
1
N9306127
00090699
N9301390
N9301270
N6221006
N6621008
1
N9302594
1
N9302595
1
N9302592
1
N9302593
1
1
N9302585
N9302596
Pkg.
Part No.
HAND HELD AND BENCH-TOP CRIMPERS:
8 mm Hand Crimper
11 mm Hand Crimper
11 mm Hand Decapper
20 mm Hand Decapper
Bench-top Vial Crimper
11 mm Crimper Jaws
Autosampler Vials/Caps/Septa Kits
PerkinElmer understands your challenges and offers a variety of kits so that you can
easily order and restock your laboratory supplies.
Description
Pkg.
Part No.
Autosampler Starter Kit
Crimper Tool (Pkg/1)
Syringe 9000 5.0 μL 0.63 mm o.d. (Pkg/1)
Vial Rack for 50 Vials 12 mm (Pkg/1)
2 mL 11 mm Crimp Top Vial, Clear (Pkg/100)
Decapper 11 mm Tool (Pkg/1)
2 mL Crimp Top Vial, Amber (Pkg/100)
11 mm Crimp Cap, Green w/ Septa
11 mm Crimp Cap, Red w/ Septa (Pkg/100)
11 mm Crimp Cap, Blue w/ Septa (Pkg/100)
Septa for Waste/Wash Vials (Pkg/50)
11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100)
1
1
1
1
1
1
1
1
1
1
2
1
N6120105
00090699
N6101390
N9301303
N9301385
N9301390
N9302680
N9302684
N9302685
N9302686
N9302780
N9306015
GC Educational Consumables Kit With Electronic Crimper
Crimper Tool 11 mm Electronic Hand Crimper w/ Battery (Pkg/1)
Syringe 5.0 μL 0.63 mm o.d. (Pkg/1)
Rack for 50 Vials 12 mm (Pkg/1)
11 mm Crimp Top Vial, 2 mL (Pkg/100)
11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100)
Elite™ Column – 5-30 M x 0.25 μm x 0.25 mm (Pkg/1)
1
1
2
1
2
2
1
N6500570
N9302592
N6101390
N9301303
N9301385
N9306015
N9316076
GC Educational Consumables Kit With Manual Crimper
Hand Crimper Tool (Pkg/1)
Syringe 5.0 μL 0.63 mm o.d. (Pkg/1)
Rack for 50 Vials, 12 mm (Pkg/1)
11 mm Crimp Top Vial, 2 mL (Pkg/100)
11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100)
Elite Column – 5-30 M x 0.25 m x 0.25 mm (Pkg/1)
1
2
2
2
2
2
1
N6500571
00090699
N6101390
N9301303
N9301385
N9306015
N9316076
Screw Top Autosampler Vial Convenience Kit – Pkg/100
1
2 mL 8 mm Clear Screw Top Vials (Pkg/100)
8 mm Black Caps w/ Preassembled PTFE/Rubber Septa (Pkg/100)
Packed in a Environmentally Clean, Re-sealable Clamshell Pack
N9301945
Crimp Top Autosampler Vial Convenience Kit – Pkg/100
2 mL 11 mm Clear Crimp Top Vials (Pkg/100)
11 mm Silver Caps w/ Preassembled PTFE/Rubber
Septa (Pkg/100)Packed in a Environmentally Clean,
Re-sealable Clamshell Pack
N9300654
N9301385
N9306015
1
1
1
ELECTRONIC CRIMPERS:
20 mm Electronic Universal Crimper
with Global Mains Plug Pack
20 mm Electronic Universal Decapper
with Global Mains Plug Pack
11 mm Electronic Universal Crimper
with Global Mains Plug Pack
11 mm Electronic Universal Decapper
with Global Mains Plug Pack
Electronic Crimper Battery
Rechargeable Battery
Easy-to-Order Convenience Kits
Description
11 mm Red Rubber Crimp Convenience Kit – Pkg/100
11 mm Red Rubber/Silver Crimp Assembly (Pkg/100)
11 mm Clear 2 mL Vial Kit (Pkg/100)
1
1
1
N9300502
N9306230
N9306231
11 mm Red Rubber Crimp Convenience Kit – Pkg/500
11 mm Red Rubber/Silver Crimp Assembly (Pkg/100)
11 mm Clear 2 mL Vial Kit (Pkg/100)
1
5
5
N9300503
N9306230
N9306231
11 mm PTFE/SIL Crimp Convience Kit – Pkg/100
11 mm PTFE/Sil Crimp Assembly (Pkg/100)
11 mm Clear 2 mL Vial Kit (Pkg/100)
1
1
1
N9300500
N9306228
N9306231
11 mm PTFE/SIL/PTFE Crimp Convenience Kit – Pkg/100
11 mm PTFE/Sil/PTFE Crimp Assembly (Pkg/100)
11 mm Clear 2 mL Vial Kit (Pkg/100 )
1
1
1
N9300501
N9306229
N9306231
9 mm Red Rubber Screw Cap Convenience Kit – Pkg/100
9 mm Red Rubber/Screw Cap Assembly (Pkg/100)
11 mm Crimp Cap Silver w/ Red
Rubber/PTFE Septa (Pkg/100)
1
1
1
N9300699
N9306200
N9306201
9 mm PTFE/Sil Screw Cap Convenience Kit – Pkg/100
9 mm PTFE/Sil Screw Cap Assembly (Pkg/100)
9 mm Clear 2 mL Vial Kit (Pkg/100)
1
1
1
N9300700
N9306202
N9306201
Order online at www.perkinelmer.com/supplies
ORDER TODAY
41
elite columns
Elite Series capillary columns
use only the finest quality
high-strength fused silica
Top 10 reasons to buy PerkinElmer
Elite Series Capillary Columns
1. Finest quality of high-strength fused silica
2. Each column individually inspected and tested
Phase Cross Reference Chart
Phase/Description
Equivalent Capillary Phase
Elite-1, Elite-1ht
100% Dimethyl
DB-1, DB-1ht, HP-1, HP-101, Ultra-1, SPB-1,
CP-Sil 5CB, CI-Sil5CBMS. RSL-150, RSL-160, Rtx-1,
BP-1, CB-1, OV-1, 007-1MS, SP-2100, SE-30
3. Reproducible results
4. Crosslinked and bonded stationary phase
Elite-200 Trifluoropropylmethyl DB-210, AT-210, VF-200MS, 007-210, Rtx-200
5. Robust column cage
Elite-5, Elite 5ms, Elite -5ht DB-5, DB-5ms, DB-5ht, Ultra-2, SPB-5, CP-Sil8CB,
5% Diphenyl – 95% Dimethyl RSL-200. Rtx-5, BP-5, CB-5, OV-5, 007-2(MPS-5),
SE-52, SE-54, XTI-5. Rtx-5ms, PTE-5, HP-5ms
6. Superior resolution
7. Wide selection of stationary phases available
8. Reduced baseline bleed
9. Lower baseline noise
10. Column lengths from 5 to 105 M
Why choose fused silica?
Many factors influence the quality of a column. Fused silica is considered
to be the purest form of glass, with fewer metal oxides (Lewis acid sites)
and hydrogen bonding (surface silanol) groups. The stationary phase is
cross linked (polymerized) and also bonded to the surface of the column
to provide a high degree of stability, resulting in lower bleeding of the
stationary phase at elevated temperatures. The superior inertness of
the column means that acidic and basic compounds can be analyzed
on the same column.
Selecting the right Stationary Phase
The inherent efficiency (large number of theoretical plates) of capillary
columns allows you to choose from relatively few types of phases,
compared to the many varieties of packed columns previously required.
Perhaps more importantly, because capillary columns are more efficient,
you will see superior resolution resulting in narrower, taller peaks that
allow easier integration from your data system. Identification of small
peaks are facilitated by a reduced baseline bleed and lower baseline
noise. Non-polar Elite-1 columns from PerkinElmer will preferentially
retain non-polar compounds, whereas the PerkinElmer Elite-200 column
phase provides high selectivity for analytes containing lone pair electrons,
such as nitro and carbonyl groups. Elite-WAX polyethylene glycol
columns are highly selective toward polar compounds such as alcohols.
What length do I need?
Typically capillary columns are available in lengths from 15 to 105 meters.
The longer the column the more resolving power, but this also increases
the analysis time. Doubling a column length only increases resolution
by approximately 40% but, under isothermal conditions, will double
the analysis time. If using a temperature programmed analysis retention
times are more dependent on the temperature than on the column
length. PerkinElmer provides columns in the most popular lengths
of 5, 10, 12, 15, 25, 30, 50, 60, 75, 100 and 105 meters depending
upon the column i.d.
42
Elite-5Amine
5% Diphenyl –
95% Dimethyl Polysiloxane
PTA-5
Elite-35, Elite-35ms
35% Phenyl – 65% Methyl
DB-35, DB-35ms, Rtx-35, SPB-35, AT-35, Sup-Herb
Elite-17, Elite-17ms, Elite-17ht DB-17, DB-17ht, HP-17, RSL-300, Rtx-50,
50% Phenyl – 50% Methyl
007-17(MPS-50), SP-2250, HP-50+
Elite-1301
6% Cyanopropylphenyl
DB-1301, Rtx-1301, CP-624
Elite-1701
14% Cyanopropylphenyl –
86% Dimethyl
DB-1701, SPB-7, CP-Sil 19CB, Rtx-1701,BP-10,
CB-1701, OV-1701, 007-1701
Elite-225
50% Cyanopropylphenyl –
50% Phenyl methyl
DB-225, HP-225, SP-2330, CP-Sil 43CB, RSL-500,
Rtx-225, BP-225, CB-225, OV-225, 007-225
Elite-WAX
Polyethylene Glycol
DB-FFAP, HP-20M, SUPELCOWAX 10, CP-WAX 52CB,
SUPEROX II, CB-WAX, STABILWAX, BP-20,
Elite-CW 007-CW, Carbowax, HP-Innowax
Elite-FFAP
Polyethylene Glycol –
Acid Modified
DB-WAX, HP-FFAP, Nukol, SUPEROX FA,
STABILWAX-DA, 007-FFAP, OV-351, DB-FFAP
Elite-608
Specialty phase for semivolatile pesticides (EPA 608)
SPB-608, NON_PAKD Pesticide, DB-608,
007-608, HP-608
Elite-624, Elite-Volatiles
Specialty phase for volatiles
DB-624, DB_VRX, VOCOL, NONPAKD AT-624, Rtx-Volatiles,
Rtx-502.2, 007-624, HP-624, CP-624, Rtx-624
Elite-CLPesticides
Specialty Phase for
Chlorinated Pesticides
Rtx-CLPesticides
Elite-VMS
Specialty Phase for Volatile
Organics on GC/MS
Rtx-VMS
Elite-PONA
DB-Petro100, Petrocol DH, HP-PONA,
Dimethyl polysiloxane
SPB-1, 007-1, RTx-1PONA
processed for the detailed
analysis of petroleum naphtha
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Elite-1 Dimethylpolysiloxane
100% Dimethyl Polysiloxane phase:
The 100% Dimethyl Polysiloxane is a highly versatile phase that is
extremely rugged, exhibiting long column lifetime, low bleed, and high
maximum operating temperatures.
Primary Applications
Elite columns are ideal for the analysis of non-polar petrochemical
samples, such as detailed hydrocarbon analysis, hydrocarbon gases,
petroleum oxygenates, petroleum aromatics, fuels, waxes, oils, sulfur
compounds, mercaptans, and carbon disulfide. It also is an excellent
phase for solvents, chemicals, flavors, fragrances, essential oils, air
toxins, chlorofluorocarbons, arson analysis, pesticides, hydrocarbons
and high-temperature applications.
Features and Benefits
■
Thermal stability to 350 °C
■
Low Bleed
■
Low baseline noise
Description
Dimensions
ELITE-1
30 M x 0.25 mm x 0.25 μm
ELITE-1
30 M x 0.32 mm x 0.25 μm
ELITE-1
60 M x 0.25 mm x 0.25 μm
ELITE-1
30 M x 0.32 mm x 1.00 μm
ELITE-1
60 M x 0.32 mm x 1.00 μm
For our complete selection of columns please visit our web site at
www.perkinelmer.com/gcsupplies
Part No.
N9316010
N9316023
N9316013
N9316024
N9316029
Elite-CLPesticides
Elite-CLPesticides is specially designed to overcome the coelutions
and analyte breakdown typically encountered in chlorinated pesticide
analyses for U.S. EPA methods 8081, 608 and CLP. Column bleed
measured by ECD is extremely low at temperatures greater than
300 °C, which is critical for baking out the column to remove
high-boiling compounds commonly found in pesticide/PCB extracts.
elite columns
Elite-1, Elite-200, Elite-5
Amine, and Elite-CLPesticides
Primary Applications
Chlorinated pesticides and herbicides. U.S. EPA Methods 504, 608,
619, 8081, 8151 and CLP.
Features and Benefits
■
Thermally stable to 340 °C
■
Low column bleed — ideal for ECD or GC/MS analysis
■
Exceeds performance criteria for U.S. EPA Methods 8081, 608, CLP
■
Baseline separation in less than 15 minutes
Description
Dimensions
Part No.
Elite-CLPesticides
Elite-CLPesticides
Elite-CLPesticides
Elite-CLPesticides
Elite-CLPesticides
Elite-CLPesticides
15 M x 0.25 mm x 0.25 μm
15 M x 0.53 mm x 0.50 μm
15 M x 0.25 mm x 0.20 μm
30 M x 0.32 mm x 0.50 μm
30 M x 0.32 mm x 0.25 μm
30 M x 0.53 mm x 0.42 μm
N9316661
N9316665
N9316667
N9316664
N9316670
N9316672
Elite-200 Trifluoropropylmethyl
Polysiloxane Capillary Column
Elite-5Amine 5% Diphenyl
and 95% Dimethyl Polysiloxane
The tubing surface of the Elite-5Amine is chemically altered to reduce
tailing of basic compounds. Thorough testing on each column ensures
that every column exceeds the requirements for analyzing ppm levels of
amines, without priming. The temperature program/bleed profile is
measured to ensure low bleed at maximum operating temperature.
This column is ideal for analyzing a wide variety of basic compounds
such as alkylamines, diamines, triamines, ethanoloamines
nitrogen-containing heterocycles.
Elite-200 is considered to be one of the best capillary columns in the
market today, solving many difficult separation problems not possible
on any other bonded stationary phase. Due to the electrophilic nature
of the fluorine-containing polymer, Elite-200 trifluoropropyl stationary
phase has a unique selectivity creating interactions with compounds
that contain groups displaying lone-pair electrons, or with
electron-rich molecules.
Primary Applications
Ideal for solvents, Freon®, fluorocarbons, alcohols, ketones, silanes
and glycols, environmental analytes and CFCs.
Primary Applications
Specifically designed for amines and other basic compounds.
Features and Benefits
Features and Benefits
■
Low bleed
■
Superior inertness
■
Thermally stable to 315 °C
■
Equivalent to USP G6 phase
■
Reduced tailing
■
Thermally stable to 340 °C
■
Low bleed at maximum operating temperature
■
Eliminates column priming
Description
Dimensions
Part No.
Elite-5Amine
Elite-5Amine
Elite-5Amine
Elite-5Amine
Elite-5Amine
15 M x 0.32 mm x 1.00 μm
15 M x 0.53 mm x 3.00 μm
30 M x 0.25 mm x 0.50 μm
30 M x 0.25 mm x 1.00 μm
30 M x 0.32 mm x 1.50 μm
N9316676
N9316681
N9316673
N9316675
N9316679
Description
Dimensions
Part No.
Elite-200
Elite-200
Elite-200
Elite-200
Elite-200
Elite-200
15 M x 0.25 mm x 0.10 μm
15 M x 0.32 mm x 1.50 μm
30 M x 0.25 mm x 0.25 μm
30 M x 0.53 mm x 1.00 μm
60 M x 0.53 mm x 0.25 μm
60 M x 0.53 mm x 1.00 μm
N9316616
N9316632
N9316619
N9316642
N9316637
N9316643
Order online at www.perkinelmer.com/supplies
ORDER TODAY
43
elite columns
Elite-Guard and EliteSiltek® guard columns
Velocity Series
Capillary Columns
Maintain the integrity of your
capillary column with a fused
silica guard column
Velocity-1, Velocity-5, and
Velocity-Wax
Using the Elite-Guard or Elite-Siltek® guard column lengthens the life
of the capillary column and improves the analyte focusing. The 5 M
length of deactivated uncoated fused silica is connected to the inlet
end of the capillary column and traps nonvolatile residues, preventing
them from collecting at the head of the analytical column. This length
of fused silica does not contain stationary phase adding only a minimal
amount of time to the analysis.
PerkinElmer offers both the intermediate-polarity deactivated guard
column and the Siltek® deactivated guard column as it is important to
match the polarity of the solvent and the polarity of the surface
deactivation. Elite-Guard intermediate-polarity deactivated column
has an operating temperature up to 325 °C. Siltek® deactivation creates
a highly inert surface for very active compounds such as chlorinated
pesticides with a maximum temperature range up to 380 °C.
Features and Benefits
■
■
■
Increase column life and performance
Elite-Guard temperature range to 325 °C
Elite-Siltek® guard temperature range to 380 °C
Description
Dimensions
Part No.
Elite-Guard
Elite-Guard
Elite-Guard
Elite-Guard
Elite-Guard
Elite-Guard
Elite-Siltek® Guard
Elite-Siltek® Guard
Elite-Siltek® Guard
5 M x 0.10 mm
5 M x 0.18 mm
5 M x 0.25 mm
5 M x 0.32 mm
5 M x 0.45 mm
5 M x 0.53 mm
5 M x 0.25 mm
5 M x 0.32 mm
5 M x 0.53 mm
N9316601
N9316602
N9301356
N9301357
N9316605
N9301358
N9316607
N9316608
N9316609
Perkin-Elmer Velocity columns are excellent for standard daily
test applications. They combine quality and affordability with
reproducible results.
Features and Benefits
■
■
■
Excellent results for theoretical plates, selectivity, & tailing factor tests
Robust column cage
Low baseline noise
Velocity-1 — 100% Dimethyl Polysiloxane
General purpose columns with a highly versatile phase that is
extremely rugged, exhibiting long column lifetime, and high operating
temperatures. Ideal for the analysis of non-polar petrochemical
samples, such as detailed hydrocarbon analysis, hydrocarbon gases,
petroleum oxygenates, petroleum aromatics, fuels, waxes, oils, sulfur
compounds, mercaptans, and carbon disulfide. It also is an excellent
phase for solvents, chemicals, flavors, fragrances, essential oils, air
toxins, chlorofluorocarbons, arson analysis, pesticides, and
hydrocarbons. Thermal stability to 350 °C.
Description
Dimensions
Part No.
Velocity-1
Velocity-1
Velocity-1
Velocity-1
Velocity-1
Velocity-1
Velocity-1
Velocity-1
Velocity-1
Velocity-1
15 M x 0.25 mm x 0.25 μm
15 M x 0.25 mm x 1.00 μm
30 M x 0.25 mm x 0.25 μm
30 M x 0.25 mm x 1.00 μm
30 M x 0.32 mm x 0.25 μm
30 M x 0.32 mm x 1.00 μm
30 M x 0.32 mm x 3.00 μm
60 M x 0.25 mm x 0.25 μm
60 M x 0.25 mm x 1.00 μm
60 M x 0.32 mm x 1.00 μm
N9306319
N9306310
N9306312
N9306323
N9306318
N9306321
N9306329
N9306320
N9306328
N9306324
Velocity-5 — 5% Diphenyl and
95% Dimenthyl Polysiloxane
This column is ideal for general purpose analyze of drugs, pesticides,
hydrocarbons, essential oils and semi-volatiles and solvent impurities.
Low polarity phase with thermal stability to 350 °C.
Wide-Bore Adapter Kit
Contains all the parts necessary to adapt packed column injectors
quickly and easily for use with wide-bore capillary columns. Includes
0-20 mL/min flow controller element, wide-bore adapter with 1⁄16 inch
fitting, wide-bore glass liner and column support hanger.
Description
Part No.
Wide-Bore Adapter Kit
N6120001
Universal Connectors
44
■
Allows for fast, leak-free connections of fused-silica columns
■
The new fused-silica tapered design allows connection of any size column
and is easy to use. (Suitable for 0.1 to 0.53 mm columns)
Description
Part No.
Universal Connector (pkg. 5)
Universal Y Splitter (pkg. 1)
Polyimide Sealing Resin (5 g)
Undeactivated Presstight Column Connectors (pkg. 5)
N9302149
N9303448
N9301343
N9303962
Description
Dimensions
Part No.
Velocity-5
Velocity-5
Velocity-5
Velocity-5
Velocity-5
Velocity-5
15 M x 0.32 mm x 0.25 μm
30 M x 0.25 mm x 0.25 μm
30 M x 0.32 mm x 0.25 μm
30 M x 0.32 mm x 1.00 μm
30 M x 0.53 mm x 0.50 μm
30 M x 0.53 mm x 1.50 μm
N9306325
N9306311
N9306313
N9306316
N9306326
N9306327
Velocity-Wax — Polyethylene Glycol
This column is ideal for intermediate to high polarity compounds.
Thermal stability to 250 °C.
Description
Dimensions
Part No.
Velocity-Wax
Velocity-Wax
Velocity-Wax
Velocity-Wax
30 M x 0.32 mm x 0.25 μm
30 M x 0.25 mm x 0.25 μm
30 M x 0.32 mm x 0.50 μm
30 M x 0.53 mm x 1.00 μm
N9306314
N9306315
N9306317
N9306322
Wafer Scribes
The PerkinElmer ceramic wafer scribe is inexpensive and
ideal for cutting polyimide fused silica capillary columns
and guard columns. The scribe is easy to hold and simple
to use. All four sides can be used as a cutting tool. (pkg. 10)
Description
Part No.
Wafer Scribes (pkg. 10)
N9301376
See page 2 for ordering information and a complete listing of PerkinElmer offices.
NEW from PerkinElmer!
Complete Consumable Application Kits
All your consumable needs in one convenient kit, designed specifically
to be used within the application requirements for OVI, Environmental,
Blood Alcohol and Biodiesel Materials Testing application notes*.
Environmental Application Kit
for U.S. EPA Method 8260B
Part No.
Promo Code: GC020804 (see details below)
Contents:
Biodiesel Application Kit ASTM 6584
Part No.
N9300670
Contents:
Autosampler Syringe 5.0 μL (0.47 mm)
Elite-5ht Column 15 M x 0.32 mm x .10 μm
Elite Guard Column (ht) 5 M x 0.53 mm
Mini Union Connector Kit – Includes Mini Union and
Nuts, 0.32 mm Ferrules and 0.53 mm Ferrules
11 mm Electronic Crimper
Crimp Vials 2 mL
Aluminum Crimp Caps 11 mm Rubber/PTFE
GC Septa
Injector Liner, Hour Glass
Pkg.
Qty.
1
1
1
5
2
1
1
1
N6101380
N9316274
N9316609
N9306128
Part No.
1
100
100
50
1
1
5
5
1
2
N9302592
N9301385
N9306015
N6621028
N6101703
Part No.
N9300672
Contents:
Pkg.
Autosampler Syringe 5.0 μL (0.47 mm)
Elite-5ht Column 15 M x 0.32 mm x 0.10 μm
Elite Guard Column (ht) 5 M x 0.53 mm
Mini Union Connector Kit – Includes Mini Union and
Nuts, 0.32 mm Ferrules and 0.53 mm Ferrules
Elite-MXT2887 SIMDIS Column
20 mm Electronic Crimper
Crimp Vials 2 mL
Aluminum Crimp Caps 11 mm Rubber/PTFE
GC Septa
Injector Liner, Hour Glass
Graphite Ferrules
Qty.
Part No.
1
1
1
5
2
1
1
1
N6101380
N9316274
N9316609
N9306128
1
1
100
100
50
1
10
1
1
5
5
1
2
1
N9316689
N9302594
N9301385
N9306015
N6621028
N6101703
09903394
Blood Alcohol Application Kit
Part No.
Promo Code: GC020802 (see details right)
Contents:
Pkg.
Qty.
Part No.
1
1
1
1
1
1
B0104236
B4000022
N9302571
N9302594
09936885
N9301357
1
1
N9316388
N9302149
OVI (Organic Volatile Impurities)
Application Kit for Pharmaceuticals
Part No.
Promo Code: GC020801 (see details below)
N9300655
Pkg.
Elite-130 / 130 m x 0.53 mm x 3.0 μm
Zero Dilution Glass Outer Liner
Zero Dilution Glass Inner Liner
Polyimide Uncoated
Deactivated Tubing / 5 m x 0.18 mm
20 mm Headspace Crimp Vials
Assembled Headspace Caps and Septa
20 mm Electronic Crimper
Application Notes NEW!
1,000
1,000
Qty.
Part No.
1
1
1
1
N9316687
N1011445
N1011446
N9301354
1
1
1
1
B0104236
B4000022
N9302594
09936887
Materials Testing or Food and Beverage
GC/Headspace Consumables Kit
Part No.
Promo Code: GC020803 (see details below)
Contents:
N9300657
Pkg.
20 mm Headspace Crimp Vials
Assembled Headspace Caps and Septa
20 mm Electronic Crimper
Application Notes NEW!
1,000
1,000
Qty.
1
1
1
1
Part No.
B0104236
N1010070
N9302594
09936888
N9300656
Pkg.
20 mm Headspace Crimp Vials
19 mm PTFE/Butyl Caps, Springs & Septa
20 mm Electronic Crimper
Application Notes NEW!
Elite-BAC-1 / 30 m x 0.32 mm x 1.8 μm
Elite-BAC-2 / 30 m x 0.32 mm x 1.2 μm
1
⁄16" to 0.5 mm 2-hole Graphite Ferrule
N9300658
20 mm Headspace Crimp Vials
1,000
19 mm PTFE-Coated/Silicone Caps, Springs & Septa 1,000
20 mm Electronic Crimper, 110 V
20 mm Electronic Crimper
Application Notes NEW!
Polyimide Deactivated
Uncoated Tubing / 5 m x 0.32 mm
Elite-Volatiles / 30 m x 0.25 mm x 1.4 μm
Universal Connector
5
Contents:
Biodiesel Application Kit
ASTM 6584 & D2887 SIMDIS2
application kits
Convenient Consumable Kits
for a Variety of Applications
1,000
1,000
5
Qty.
1
1
1
1
1
1
1
Part No.
B0104236
N1010070
N9302594
09936886
N9316579
N9316577
N9306001
Save on your next
Application Kits
Consult your Authorized PERKINELMER
Sales Office for special promotions.
* For full downloadable pdf format application notes,
please visit: http://las.perkinelmer.com/applications
Order online at www.perkinelmer.com/supplies
ORDER TODAY
45
headspace and headspace trap accessories
For TurboMatrix Headspace
and Headspace Trap
Sample Trays
For use on the Mid-Range or High-Capacity headspace sampler.
Description
Part No.
TurboMatrix 40 Mid-Range Sample Tray
TurboMatrix 110 High-Capacity Sample Tray
M0413592
M0413593
Transfer Lines
Description
Siltek Deactivated Fused-Silica
Siltek Deactivated Fused-Silica
Tubing i.d.
Length
0.25 mm
0.32 mm
5m
5m
N9316607
N9316608
Miscellaneous Accessories
TurboMatrix 40
Headspace Trap
Description
Part No.
Gas Chromatography – Theory and Practice,
Static Headspace Book by L. Ettre and B. Kolb
N1011210
Cold Trap Options
Headspace Trap instruments only.
Sample Head Assembly Replacement Parts
Description
Part No.
Platinum/Iridium Needle, Wide-Bore
Platinum/Iridium Needle, Small-Bore
Platinum/Iridium Needle, Jet
Silcosteel Needle, for Headspace Trap Only
Stainless Steel Needle, Wide-Bore
Stainless Steel Needle, Small-Bore
Stainless Steel Needle, Jet (ships with instrument)
B0144169
B0500959
B0510364
N6700130
B0131385
B0500987
B4000011
2
Needle Seal Assembly (without O-Rings)
B0500833
3
O-Ring for Needle Seal Assembly (pkg. 10)
B0198110
4
Vespel Ferrule 1⁄16 in. (pkg. 10)
09920127
5
Male Nut 1⁄16 in.
N9302832
6
GLT Adapter Tube
GLT Adapter Tube, Silcosteel
B0503956
N6700113
7
Graphite/Vespel Ferrule 1⁄16 in. x 0.4 mm
For use with 0.25 mm i.d. Transfer Line, pkg. 10
Graphite/Vespel Ferrule 1⁄16 in. x 0.5 mm
For use with 0.32 mm i.d. Transfer Line, pkg. 10
09920104
8
Nut 1⁄16 in. Swagelok
N9300059
9
Fused-Silica Capillary Transfer Line:
0.25 mm i.d. x 5 m length
0.32 mm i.d. x 5 m length
N9301356
N9301357
1
Description
Part No.
TurboMatrix HS Trap Cold Trap Tube (Carbopack C)
TurboMatrix HS Trap Air Monitoring Trap*
N6200150
M0413628
*Trap comes standard with the instrument.
Headspace Sample Head
Assembly Schematic
09903700
1
9
8
7
6
Solid Glass Blocking Trap
46
Part No.
5
4
2
Description
Part No.
Block for use in standard headspace mode.
N6701170
3
2
3
See page 2 for ordering information and a complete listing of PerkinElmer offices.
headspace vials/caps
Headspace Vials,
Caps, and Septa Kits
from PerkinElmer
One-step solution – from
field sample to lab results
PerkinElmer offers a variety of GC headspace vials, caps and septa
to fulfill your application needs. Our patented vial and cap design
incorporates pressure-relief features which guarantee safe operation
with the high pressure typically developed during thermostatting.
Ordinary vials and caps without these safety features may burst.
All of our headspace vials are 20 mL, providing a maximum liquid
sample volume of 15 mL. They have a greater wall thickness and
round base which enables them to withstand pressure up to 60
psig. Low-volume sampling can be achieved by using a 6 mL
crimp vial and vial adapter. All PerkinElmer headspace vials are
manufactured to specific tolerances that are guaranteed to fit
within PerkinElmer instruments.
Headspace Vials with
Write-on Patch and Fill Lines
Features and Benefits
■
Patented vial and cap design guarantees safe operation
■
Manufactured to specific tolerances
guaranteed to fit PerkinElmer instruments
■
Lot-tested, certified and approved septa
deliver reproducible results
Headspace Screw Top
Vials and Preassembled Caps
NEW from PerkinElmer, headspace screw top vials and preassembled
caps allow for samples to be taken in the field and directly analyzed
on the PerkinElmer® TurboMatrix™ Headspace Sampler* without
having to transfer the sample into another vial, streamlining the
sampling process and increasing your productivity. Screw thread vials
are designed for a guaranteed fit. PerkinElmer septa are lot tested
for impurities. The cap is conveniently preassembled for ease-of-use
and packed in clean Mylar® bags to reduce the risk of contamination.
Description
Pkg
Part No.
20 mL Headspace Screw Top Vials
20 mL Headspace Screw Top Vials
18 mm PTFE/Butyl Assembled Caps/Septa 3.2 mm thickness
18 mm PTFE/Silicone Assembled Caps/
Septa 3.2 mm thickness
18 mm Red PTFE/White Silicone metal Screw Cap/
Septa 1.3 mm thickness 8 mm hole
18 mm White PTFE/Transparent Blue Silicone
metal Screw Cap/Septa 1.3 mm thickness 8 mm hole
18 mm Blue PTFE/White Silicone metal Screw Cap/
Septa 1.5 mm thickness 8 mm hole
18 mm Gray PTFE/Red Butyl metal Screw Cap/
Septa 1.6 mm thickness 8 mm hole
100
1000
100
100
N9306075
N9306078
N9306076
N9306077
100
N6356474
100
N6356475
100
N6356476
100
N6356477
Vial Rack Holder:
Description
Pkg
Part No.
36-Vial Polypropylene 20 mm Holder
1
N9301304
Description
Pkg
Part No.
20 mL Headspace Crimp Top Vials with
Write-On White Patch and Fill Lines
20 mL Headspace Crimp Top Vials with
Write-On White Patch and Fill Lines
20 mL Headspace Screw Top Vials with
Write-On White Patch and Fill Lines
20 mL Headspace Screw Top Vials with
Write-On White Patch and Fill Lines
10 mL Clear Crimp Top Headspace Vials
10 mL Clear Screw Top Headspace Vials
20 mL Clear Crimp Top CTC Headspace Vials
1000
N9303348
100
N9303349
1000
N9306241
100
N9306240
100
100
100
N6356478
N6356479
N6356471
Headspace Crimp-top
Vials and Preassembled Caps
Description
Pkg
Part No.
6 mL Headspace Clear Glass Vial* **
Low-Volume Vial Adapter
20 mL Headspace Clear Glass Vial
20 mL Headspace Crimp Top Vials
20 mL Headspace Crimp Top Vials with
Write-On White Patch and Fill Lines
20 mL Headspace Crimp Top Vials with
Write-On White Patch and Fill Lines
Red Butyl Rubber Septa/Cap/Spring
Red Butyl Rubber Septa/Cap/Spring
Red Butyl Rubber Preassembled
Red PTFE-Coated Butyl Rubber/Cap/Spring
125
10
1000
100
1000
N9302134
N6120110
B0104236
N9306079
N9303348
100
N9303349
100
1000
1000
100
B0159356
B0159357
N1010070
B0104239
*Not compatible with TurboMatrix HS 110 headspace sampler
**Use with Low-Volume Vial Adapter (N6120110)
Order online at www.perkinelmer.com/supplies
ORDER TODAY
47
headspace and crimp-top caps and septa
Headspace Crimp-top
Caps and Septa
Crimp Top Cap and Septa – GC Headspace
(CTC Autosampler)
Description
Pkg
Part No.
20 mm magnetic cap/septa 8 mm hole w/3.2 mm
thickness Silicone/PTFE Transparent White liner
20 mm magnetic cap/septa 8 mm hole w/3.0 mm
thickness Silicone/PTFE Transparent Blue liner
20 mm magnetic cap/septa 8 mm hole w/3.0 mm
thickness PTFE/Butyl gray
20 mm magnetic cap/septa 8 mm hole w/3.0 mm
thickness Gray Butyl liner
20 mm magnetic cap/septa 8 mm hole w/3.0 mm
thickness Pharma fix Butyl/PTFE
20 mm magnetic cap/septa 8 mm hole w/3.2 m
thickness Aluminum/Silicone liner
20 mm magnetic cap/septa 8 mm hole w/1.3 mm
thickness Silicone/PTFE Trans Blue (SPME liner)
20 mm magnetic bi-metal cap/septa w/3.0 mm 8 mm
thickness PTFE/Blue liner
20 mm bi-metal cap/septa w/3.0 mm
Silicone 8 mm thick PTFE Transparent Blue liner
100
N6356558
100
N6356559
100
N6356560
100
N6356561
100
N6356562
100
N6356563
100
N6356564
100
N6356565
100
N6356566
Headspace Crimp-top Septa and Pre-assembled Caps
Description
Pkg
Part No.
Red PTFE-Coated Butyl Rubber/Cap/Spring
Red PTFE-Coated Butyl Rubber Preassembled
Aluminum-Coated Silicone/Cap/Spring
Aluminum-Coated Silicone/Cap/Spring
Aluminum-Coated Silicone Preassembled
PTFE-Coated Silicone/Cap/Spring
PTFE-Coated Silicone/Cap/Spring
PTFE-Coated Silicone Preassembled
20 mm Gray Butyl/PTFE pre-assembled cap/septa/spring
20 mm Gray Butyl/PTFE pre-assembled cap/septa/spring
clear 20 mL headspace with write-on patch and fill lines
Gray PTFE/Butyl Kit, unassembled cap/septa/spring
Gray PTFE/Butyl Kit, unassembled cap/septa/spring
20 mm Gray Butyl pre-assembled cap/septa/spring
20 mm Butyl pre-assembled cap/septa/spring
clear 20 mL headspace with write-on patch and fill lines
Gray Butyl Kit unassembled cap/septa/spring
Gray Butyl Kit unassembled cap/septa/spring
1000
1000
100
1000
1000
100
1000
1000
1000
100
B0104240
B4000025
B0104243
B0104244
B4000028
B0104241
B0104242
B4000022
N9306264
N9306265
100
1000
1000
100
N9306266
N9306267
N9306268
N9306269
100
1000
N9306270
N9306271
Septa Recommended Temperatures
Material
Red Butyl Rubber
Gray Butyl Rubber
Gray PTFE-Coated Butyl Rubber
Red PTFE-Coated Butyl Rubber
Aluminum-Coated Silicone
PTFE-Coated Silicone
48
Upper Temp Limit at Vial
100 ºC
130 ºC
130 ºC
100 ºC
210 ºC
220 ºC
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Inertness
Fair
Fair
Good
Good
Good
Good
Headspace Vial, Septa,
and Cap Kits
PerkinElmer understands your challenges and offers a variety of kits
so that you can easily order and restock your laboratory supplies.
headspace starter kits
One-step solution – from field sample
to lab results – NEW PerkinElmer
Headspace Starter Kits
Headspace Mini Starter Kit
The same great consumables as the Headspace Starter Kit (N6710195) without the
“Static Headspace Gas Chromatography Theory and Practice” book, and with fewer
vials – 200 total (100 each crimp and screw top vials).
Part No.
Headspace Mini Starter Kit:
N6710197
Contents:
Pkg.
Qty.
20 mL Headspace Crimp Vials
20 mm PTFE/Butyl Septa/Cap/Springs
20 mm PTFE/Silicone Septa/Cap/Springs
20 mm Aluminum Silicone Septa/Cap/Springs
O-Rings
Needle Seal Assemblies
Pressure Gauge with Needle for Vials
20 mm Hand Crimper
20 mL Headspace Screw Top Vials*
18 mm PTFE/Butyl Assembled Cap and Septa*
18 mm PTFE/Silicone Assembled Cap and Septa*
100
100
100
100
10
1
1
1
100
100
100
1
1
1
1
1
2
1
1
1
1
1
Part No.
N9306079
B0104239
B0104241
B0104243
B0198110
B0500833
B0501377
N9302785
N9306075
N9306076
N9306077
*Not compatible with TurboMatrix HS 110 headspace sampler
Headspace Starter Kit
Offers a variety of headspace consumables so you can evaluate different types of septa and vials for your sampling requirements.
Part No.
TurboMatrix™
Headspace Starter Kit:
N6710195
Contents:
Pkg.
Qty.
Part No.
20 mL Headspace Crimp Vials
20 mm PTFE/Butyl Septa/Cap/Springs
20 mm PTFE/Silicone Septa/Cap/Springs
20 mm Aluminum Silicone Septa/Cap/Springs
O-Rings
Needle Seal Assemblies
Pressure Gauge with Needle for Vials
“Static Headspace Gas Chromatography Theory and Practice” Book by B. Kolb and L.S. Ettre
20 mm Hand Crimper
20 mL Headspace Screw Top Vials*
18 mm PTFE/Butyl Assembled Cap and Septa*
18 mm PTFE/Silicone Assembled Cap and Septa*
100
100
100
100
10
10
1
1
1
100
100
100
5
1
1
1
1
2
1
1
1
5
1
1
N9306079
B0104239
B0104241
B0104243
B0198110
B0500833
B0501377
N1011210
N9302785
N9306075
N9306076
N9306077
*Not compatible with TurboMatrix HS 110 headspace sampler
Order online at www.perkinelmer.com/supplies
ORDER TODAY
49
headspace convenience kits
Headspace Convenience
and Stopper Kits
Headspace Cap and Stopper Kits
Description
Pkg.
Butyl Rubber Stoppers with Caps
Butyl Rubber Stopper
Knurled Caps
PTFE/Silicone Injector Septa
Injection-Septa
1000
100
100
12
12
Qty.
10
10
1
Part No.
B0110728
B0038137
B0099814
00091357
00092388
Choosing the Right Septa for
your Analysis
Although a wide variety of septa is available, chemical compatibility and temperature
are the most critical to the analysis. Temperature applies not only to the vial, but also to
the temperature of the instrument’s needle used for pressurization and sample transfer,
which is heated to prevent condensation. A needle temperature higher than the vial
temperature setting can decompose the septum material. PTFE coated silicone and
aluminum-coated silicone offer the highest temperature operating limits.
(See Septa Recommended Temperature Chart page 48.)
Headspace Convenience Kits
Description
Pkg.
Qty.
20 mL Butyl HS Convenience Kit
20 mm Red Butyl Assembly
20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap
100
100
100
1
1
N9303990
N1010070
N9303349
20 mL PTFE/Butyl HS Convenience Kit
20 mm Red PTFE/Butyl Assembly
20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap
100
100
100
1
1
N9303991
B4000025
N9303349
20 mL PTFE/Silicone Convenience Kit
20 mm PTFE/Silicone Assembly
20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap
100
100
100
1
1
N9303992
B4000022
N9303349
20 mL Al/Silicone Convenience Kit
20 mm Aluminum/Silicone Assembly
20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap
100
100
100
1
1
N9303993
B4000028
N9303349
SAVE - Volume discounts
available on Vials, Caps, Septa
and Convenience kits.
Contact Your Area PerkinElmer Sales Office for details and promotions.
50
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Part No.
crimping tools
Crimping Tools
Electronic Handheld
and Benchtop Crimpers
Crimping Tools
Whatever your need may be, PerkinElmer offers a wide range of
crimping tools for your convenience. Our universal voltage,precision
control, power crimpers with adjustable settings are designed to
deliver hundreds of crimps on a single battery charge.
Electronic Crimpers:
Description
Pkg.
20 mm Electronic Universal Crimper with Global Mains Plug Pack
20 mm Electronic Universal Decapper with Global Mains Plug Pack
11 mm Electronic Universal Crimper with Global Mains Plug Pack
11 mm Electronic Universal Decapper with Global Mains Plug Pack
Electronic Crimper Battery
Rechargeable Battery
1
1
1
1
1
1
Part No.
N9302594
N9302595
N9302592
N9302593
N9302585
N9302596
Electronic Crimpers
Features and Benefits
■
Universal voltage
■
Precision control crimping
■
Ergonomically-designed grip
■
Numerous reproducible crimps from
a single charge
■
Includes standard Black & Decker®
VersaPak® Gold battery and charger
■
Fully rechargeable
Hand Held and Bench-top Crimpers:
Description
8 mm Hand Crimper
11 mm Hand Crimper
11 mm Hand Decapper
20 mm Hand Crimper
20 mm Hand Decapper
Bench-top Vial Crimper
11 mm Crimper Jaws
20 mm Crimper Jaws
Pkg.
Part No.
1
1
1
1
1
1
1
1
N9306127
00090699
N9301390
N9302785
N9301270
N6621006
N6621008
N6621009
For more details, call your local
representative or visit:
www.perkinelmer.com/gcsupplies
Order online at www.perkinelmer.com/supplies
ORDER TODAY
51
thermal desorption
Packed traps specifically
designed for PerkinElmer
Thermal Desorbers
Air Monitoring Trap
Low flow trap packed with carbonaceous sorbents suitable for
ozone precursor and air toxics monitoring.
Cold Traps
Cold Traps Fittings and Accessories
TurboMatrix Thermal Desorption Trap Supplies
Trap supplies from PerkinElmer, the market leader in thermal desorption, will
provide exceptional analytical performance. Used for U.S. EPA Method TO17, the
PerkinElmer standard trap, packed with Tenax™, on the TurboMatrix™ Thermal
Desorber, will improve productivity and trapping capacity. The TurboMatrix air
monitoring trap is packed with carbonaceous sorbents suitable for ozone
precursor and air toxics monitoring.
Description
Cold Traps for TurboMatrix
Air Monitoring Trap
Empty Trap
Tenax™ TA 60/80 Packed Trap
Carbopack® C Packed Trap
Cold Traps for ATD 400
Air Monitoring Trap
Trap Nuts (2 required)
Trap Tube Low Flow, Empty
(Narrow-bore at one end. Allows minimum
gas flow during trap desorption)
Tenax™ TA 60/80 Packed Trap
Empty Trap
52
Qty.
Part No.
1
1
1
1
M0413628
M0413627
M0413535
N6200150
1
1
1
L4275108
L4275009
L4275107
1
1
L4275089
L4271106
Description
Qty.
Graphite Ferrule
2
SilTite™ Ferrule (GC/MS) 0.4 mm
10
SilTite™ Ferrule (GC/MS) 0.5 mm
10
10
SilTite™ Ferrule (GC/MS) 0.8 mm
SilTite™ Nuts
5
PTFE Ferrule
10
5
Graphite/Vespel® Ferrule for ATD 400
Valco® Graphite/Vespel® Ferrule for ATD 400
5
Trap Filter Disk
Trap Packing Disk
20
Trap Packing Retaining Spring
5
Quartz Wool (untreated)
5g
Cold Trap Packing Tool
Cold Trap Removal Tool
Regulator 0 – 60 psig
Backflush Nozzle for ATD 400
Internal Standard Injection Accessory for ATD 400
Liquid Nitrogen Accessory for ATD 400
Gauze Loading Rig
Replacement Plastic Plunger for Gauze Loading Rig
See page 2 for ordering information and a complete listing of PerkinElmer offices.
Part No.
L4271187
N9306093
N9306094
N9306095
N9306096
L4275110
L1003027
L1003028
L1003030
L4271290
N6301054
N6102354
L4271203
L4271205
N6101474
L4275072
L4270010
L4270009
L4070023
L4071151
thermal desorption
Packing material tube identification
and polarity now on
every tube!
SVI™ Soil Vapor Intrusion™ Tubes
Unconditioned Thermal
Desorber Tubes
Soil vapor intrusion occurs when toxic compounds that are present in
the air space in soil of a contaminated location have ways of entering
a building, potentially creating a health risk.
Our new multi-bed construction extends the hydrocarbon range
past naphthalene while retaining the lighter components, enabling
larger sample volumes, hence, enhancing detection limits. Unique
design that meets the challenges and criteria of the EPA regulations
for air monitoring.
Fully conditioned
Thermal Desorber tubes shown
Unconditioned Thermal Desorber Tubes
■
Enhanced recoveries, even of highly contaminated sites
For your convenience, new low-cost thermal desorber tubes are offered
in both stainless steel and glass. Each tube maintains its unique serial
number which is etched for easy identification. Tubes are offered
with a variety of sorbent packing materials for many GC applications
including indoor and outdoor air monitoring, analysis of flavors and
fragrances and the analysis of outgassing from packaging, polymers,
pharmaceuticals and semi-conductor material. These tubes are
unconditioned and ship with plastic end caps for short-term storage.
■
From chloromethane through diesel range hydrocarbons
■
After the analysis, tubes are clean and ready for re-sampling
reducing costs
Packed Unconditioned Sample Tubes,
Plastic End Caps (pkg. 10)
Sorbent
Air Toxics
Carbopack® B60/80
Carbosieve® SIII 60/80
Tenax™ GR 60/80
Tenax™ TA 60/80
Chromasorb™ 60/80
Carbopack® B 60/80
Carbopack® C 60/80
Carbosieve® SIII 60/80
Carbotrap® C/B
NIOSH
Stainless Steel
Part No.
Glass
Part No.
N9307050
N9307051
N9307052
N9307053
N9307054
N9307055
N9307056
N9307058
N9307059
N9307060
N9307061
N9307062
N9307063
N9307064
N9307057
N9307065
N9307066
Empty Sample Tubes without Caps
Description
Stainless Steel TD tubes Conditioned
Stainless Steel TD tubes Un-Conditioned
Conditioned Thermal Desorber Tubes
Stainless steel and glass sample tubes are available with a wide
variety of packing materials from single to multi-bed. PerkinElmer
Thermal Desorber tubes will now be printed with the packing material
clearly identified on each tube. In addition an arrow will also be printed,
which points to the end of the tube where sample is drawn from, and
also indicates the end that desorb vapors will exit.
Each tube is etched with a unique serial number for ease of traceability
and adsorbent identification. Stainless steel tubes may also be fitted
with clips that accept adhesive labels for identification. Packed tubes
are shipped with long-term brass storage caps and all PerkinElmer
thermal desorber tubes are thermally conditioned and tested for
background and backpressure.
Packed Conditioned Sample Tubes,
Brass Long-Term Storage Caps (pkg. 10)
“NOT for Analytical test applications”, USE N6200119 PTFE caps and
O-ring. (pkg. 20)
Sorbent
Description
Part No.
Stainless Steel (pkg. 10)
Glass (pkg. 10)
Stainless Steel (pkg. 100)
L4270128
L4071594
L4270129
Empty Sample Tubes with Caps
Description
Part No.
Stainless Steel (pkg. 10)
Glass Lined Stainless Steel (pkg. 10)
Glass (pkg. 10)
M0413595
M0413597
M0413598
Part No.
N9306277
N9306278
Air Toxics
Carbopack® B60/80
Carbosieve® SIII 60/80
Tenax™ GR 60/80
Tenax™ TA 60/80
Chromasorb™ 60/80
Carbopack® B 60/80
Carbopack® C 60/80
Carbosieve® SIII 60/80
Carbotrap® C/B
NIOSH 2549
Order online at www.perkinelmer.com/supplies
Stainless Steel
Part No.
Glass
Part No.
N9307001
N9307002
N9307003
N9307004
N9307005
N9307006
N9307000
N9307008
N9307009
N9307010
N9307011
N9307012
N9307013
N9307007
N9307026
N9307038
N9307037
ORDER TODAY
53
thermal desorption
Thermal Desorber
kits and accessories
from PerkinElmer
Thermal Desorber Industrial
Hygiene Application Kit
All your consumable needs in one convenient kit, designed specifically
for Industrial Hygiene using Thermal Desorption*.
Workplace Air Monitoring Industrial
Hygiene Application Kit**
Thermal Desorber Starter Kit
PerkinElmer’s convenient starter kit includes all products you need to
run the TurboMatrix Thermal Desorber.
Features and Benefits
■
All items available under one part number in a convenient kit
■
Guaranteed PerkinElmer parts
■
Improved chromatography with exceptional analytical
performance using PerkinElmer parts
Part No.
M0413541
Contents:
Glass Fiber Separator Disks
Glass Sample Tubes
Glass Wool
Graphite Ferrules
O-Ring
O-Ring, Viton
Packing Gauze
PTFE Filter Discs
PTFE Filter Discs – Large
Retaining Spring
Sample Tube-5 mL
Stainless Steel Retaining Spring
Stainless Steel Sample Tubes – Capped
Tenax TA 60/80, Mesh-15 g
Trap Tube Nuts
Trap Tubes
Pkg.
Qty.
6
10
1
2
1
1
100
10
10
50
1
2
10
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Part No.
N6710188
Contents:
Pkg.
Cold Trap O-Ring, 0.145 i.d./0.070 w.d.
Cold Trap Tube (Tenax TA)
Empty Glass Sample Tubes – No caps
Graphite Ferrule
Pen Clips for Stainless Steel Sample Tubes
PTFE Ferrule
PTFE Filter Disk – Either side of the cold trap
Tenax TA Stainless Steel Sample Tubes
Qty.
1
1
10
2
10
10
10
10
1
1
1
1
1
1
1
1
09200091
L4275089
L4071594
L4271187
L4071029
L4275110
L1003030
N9307005
* For full downloadable pdf format application notes,
please visit: http://las.perkinelmer.com/applications
** Applicable to TurboMatrix 100/150/300/350 and 650 only.
Part No.
L4271290
M0413598
54120790
L4271187
L1003006
L1003008
L4071034
L1003030
L1003029
L4071123
04970673
L6301054
M0413595
04978064
L4275009
M0410094
Consult your authorized PERKINELMER
Sales Representative for tier volume
Thermal Desorber Caps and Accessories
Description
Brass Long-Term Storage Caps
Recommended for long-term storage,
two required per tube. Also requires Teflon®
Ferrule (L1003015).
Combined Teflon® Ferrule
For use with 1⁄4 in Brass Long-Term Storage
Caps (09908851), two required per tube.
Diffusion Caps – Standard
For passive air sampling, to ensure
correct diffusion path length.
Diffusion Caps with Membrane
As above, with silicone membrane inserted.
Pen Clips
For Stainless Steel Thermal Desorber Tubes.
PFA Teflon® Ferrules
For TurboMatrix Storage End Caps.
TurboMatrix Analytical Caps
PTFE caps with o-ring, required for use on
the TurboMatrix instrument during analysis.
Pkg.
09908851
5
L1003015
10
L4070207
10
L4070208
10
L4071029
20
M0413625
20
N6200119
Delivering enhanced VALUE and outstanding
SAVINGS on the products you use most!
Part No.
1
discounts and promotions.
54
Part No.
For a full listing of thermal desorber
kits and supplies please visit us at:
www.perkinelmer.com/gcsupplies
See page 2 for ordering information and a complete listing of PerkinElmer offices.
thermal desorption
Cost-effective,
round-the-clock air monitoring
The Model STS 25 sequential tube sampler is used for the
continuous monitoring of atmospheric concentrations of
volatile organic compounds.
The unit is housed in a compact weatherproof box and allows the
monitoring of indoor and outdoor atmospheres. This convenient
portable unit designed for pumped air sampling of up to 24 tubes,
offers cost-effective, round-the-clock monitoring for the workplace
and ambient air. It can be operated by a 12 V battery or can connect
to 120 V/24 V mains electricity, making it extremely versatile for use in
the laboratory or in the field. The sampler includes cables with jack plug
connectors (for use with the monitoring pump) and a set of diffusion
limiting caps. Maintenance kit and accessories are also available.
Features and Benefits
■
Portability – small, lightweight and compact
■
Variable sampling times – operator adjusted from minutes to hours
■
Sample integrity – diffusion limiting caps block the sample
from contaminants
■
Sampling versatility – heaters are included to prevent condensation
Description
Part No.
Model STS 25 Sequential Tube Sampler
Model STS 25 Maintenance Kit
Includes; Rotor Tube Seals (pkg. 50), Filter Disks (pkg. 25),
Diffusion Limiting Caps (pkg. 5) and Rotor Seal (pkg. 10)
12 V Rechargeable Battery
Air Monitoring Pump (120 V)
Cable (for connecting STS 25 to a generic 12 V battery)
Diffusion Limiting Caps (pkg. 5)
Electrical Adapter
Allows for direct connection to wall outlet 120 V/240 V.
Also acts as a battery charger for 12 V battery.
Rotor Filter Disk
Viton O-Ring (pkg. 50)
L4280001
N6609060
L4280002
L4271275
L4285007
L4285001
L4280003
L4281023
L4275033
Consumable Application Kits
All your consumable needs in one convenient kit, designed specifically to be used
within the application requirements for Air Monitoring and Ozone Precursor
application notes*.
Air Monitoring Application Kit
Part No.
N6710187
Contents:
Pkg.
Qty.
Air Toxics Stainless Steel Thermal Desorber Tubes
Air Monitoring Trap
Methyl Silicone Column 100 m x 0.32 mm x 5 μm
10
1
1
1
1
1
Part No.
N9307001
M0413628
N6300155
Ozone Precursor Application Kit
Part No.
N6710186
Contents:
Alumina PLOT Column 50 m x 0.32 mm i.d.
Air Monitoring Trap
Methyl Silicone Column 50 m x 0.32 mm x 1.0 μm
Pkg.
Qty.
1
1
1
1
1
1
Part No.
N6301107
M0413628
N6301108
Ozone Precursor Accessories
Personal Monitoring Pump
This compact and lightweight sampler combines convenience
and useful functions for accurate sampling.
The personal monitoring pump offers two modes of sampling which are
easily activated by turning the selector dial located at the back of the
sampler. Two low-flow modes of sampling allow constant flows from
5 – 200 cc/min, as well as constant pressure for multiple sorbent-tube
sampling from 1 – 350 cc/min (combined flow rates).
Description
Part No.
Personal Monitoring Pump 5 – 200 mL/min 110 V
N6102351
Description:
Part No.
Alumina PLOTTM Column.
50 m x 0.32 mm i.d.
Nafion Dryer
Particulate Filter Kit
Includes disposable filter and fittings.
For use in the ozone precursor analyzer.
Restrictor Tubing
N6301107
04974414
N6300063
N9301355
* For full downloadable pdf format application notes,
please visit: http://las.perkinelmer.com/applications
Order online at www.perkinelmer.com/supplies
ORDER TODAY
55
Hydrogen and Air Gas Generators
New and Improved
next generation
Generators for your
application needs
No Maintenance Hydrogen Generators
A Safe Source of Hydrogen
Both the PGX-H2 and the No Maintenance Hydrogen Generators have an auto shutoff
procedure that places the units in standby in the event of an internal error and
selectable alarms allow the user to be informed whenever operating conditions vary
from the set point.
PGX-H 2 Hydrogen Generators
Pure gas hydrogen generator employ the newest membrane
technology available for the safe production of pure hydrogen gas.
This patented design is ideal for operation with gas analyzers, as fuel
gas for flame tools, or as a source for pure hydrogen in plasma
chambers and other isolated environments. Electrolytic membrane
technology is preferred over alternative hydrogen generating
techniques because it is clean, requires less maintenance and there is
no need to store chemicals to maintain operation. The generators offer
silent operation and require only deionized or distilled water with no
caustic solutions that can affect the purity of the hydrogen.
Technical Specifications for PGX-H2
56
Electrolysis cell
PEM Membrane type
H2 purity
99.9999%
Delivery pressure
100 psig – 7 barg (max)
H2 flow rate
Adjustable, according to model
(100 – 160 – 250 – 300 – 500 – 600 mL/min)
Safety
Auto shut-off
User interface
Set points, system status
Display
4 row x 34 character LCD, set points, status,
alarms
Indicator lights
Power ON, System OK, System error
Outputs
RS232C, bi-directional
Options
Remote control
Cascading via RS-485 of up to 32 units in parallel
for models 250 and 500 only (patented feature)
Description
Part No.
PGX-H2 100 mL/min of hydrogen
PGX-H2 160 mL/min of hydrogen
PGX-H2 250 mL/min of hydrogen
PGX-H2 500 mL/min of hydrogen
PGX-H2 Desiccant Cartridge, Fitting and Refill Kit
PGX-H2 Desiccant Refill (sufficient for 3 cartridge refills)
PGX-H2 Deionizer Bag
N9306058
N9306059
N9306060
N9306061
N9306064
N9306065
N9307097
The No Maintenance (NM-H2) Hydrogen Pure Gas Generators employ the newest
membrane technology available for electrolytic production of pure hydrogen gas,
including exclusive no maintenance auto-drying technology.
Technical Specifications for No Maintenance
Electrolysis cell
PEM Membrane type
H2 purity
99.9999%
Auto Drying System
No maintenance of drying cartridges
(exclusive system)
Delivery pressure
155 psig – 10 barg (max.)
H2 flow rate
Adjustable, according to model
(100 – 160 – 250 – 300 – 500 – 600 – 1000 mL/min)
Safety
Auto shut-off
User interface
Set points, system status
Display
4 row x 34 character LCD, set points, status, alarms
Indicator lights
Power ON, System OK, System error
Options
Remote control
Cascading via RS-485 of up to 32 units in parallel for
models 250 and 500 only (patented feature)
Description
Part No.
100 mL/min of hydrogen
160 mL/min of hydrogen
250 mL/min of hydrogen
500 mL/min of hydrogen
1000 mL/min of hydrogen
N9307070
N9307071
N9307072
N9307073
N9307074
Accessories
Description
Part No.
Cable for Cascading
I/O Board
Remote control RS-232
(Includes converter, cables, software)
Auto refill
Deionizer LE bag
Triangle deionizer LE bag
N9307093*
N9307094
N9307095*
* Requires I/O Board
See page 2 for ordering information and a complete listing of PerkinElmer offices.
N9307096*
N9307097
N9307098
Zero and Ultra Air Generators
The Zero / Ultra Zero Air Generators produce laboratory grade purified
air for FID (flame ionization detectors) and other detectors. Designed
with safety and convenience in mind, this system will generate purified
and hydrocarbon free air from an existing in-house oil-free compressed
air supply, eliminating the need for inconvenient high-pressure gas
cylinders. Eliminating gas cylinders reduces annual operating costs
associated with materials, labor, and down-time.
The Zero / Ultra Zero Air Generator series removes HC pollutants to
less than 0.1 ppm, and all forms of particles. Operation of the
generator requires low levels of electrical power consumption. This
complete turnkey system is engineered with the highest quality
components, is easy to install, and requires minimal annual
maintenance. The Ultra Zero Air Generators will remove CO and HC
pollutants to less than 0.1 ppm, and NOx contaminants to 1 ppm.
Carbon dioxide is also removed to about 1 ppm levels.
WALL
MOUNTABLE
Ultra Zero Air Generators
Features and Benefits
Specifications for Zero Air
Part No.
N9307075
N9307076
N9307077
N9307078
N9307079
■
Flow rate: < 0.1 ppm HC; < 0.1 ppm CO; < 1 ppm NOx; < 5 ppm CO2
Outlet
Zero Air
1500
mL/min
3000
mL/min
6000
mL/min
15000
mL/min
30000
mL/min
■
Produce laboratory-grade purified air for the most accurate and
convenient calibration of testing equipment
Maximum
Continuous
Output
Flow Rate
1.5 L/min
3.0 L/min
6.0 L/min
15.0 L/min
30.0 L/min
■
Electrical
Requirements
230/115 VAC 230/115 VAC 230/115 VAC 230/115 VAC
250 W max
250 W max
250 W max
480 W max
230/115 VAC
480 W max
Designed with safety and convenience in mind, this system will
generate purified air from an existing in-house oil-free compressed
air supply, eliminating the need for inconvenient high-pressure
gas cylinders
■
Temperature /
Pressure
Control Board
N/A
Included
Eliminate gas cylinders reducing annual operating costs associated
with materials, labor and downtime, and reduces risk of injury
to workers
■
Will remove CO and HC pollutants to less than 0.1 ppm and NOx
contaminants to 1 ppm. Carbon dioxide is also removed to about
1 ppm levels. Operation of the generator requires low levels of air
consumption and electrical power
■
Fully supported by PerkinElmer Service Organization
Included
Included
Included
Description
Part No.
1.5 L/min of air (without compressor)
3.0 L/min of air (without compressor)
6.0 L/min of air (without compressor)
15.0 L/min of air (without compressor)
30.0 L/min of air (without compressor)
N9307075
N9307076
N9307077
N9307078
N9307079
Specifications for Zero and Ultra Zero Air
Outlet Hydrocarbon Concentration
Outlet Carbon Monoxide Concentration
Outlet Particles < 0.5 Microns Removed
Outlet Air Temperature
Max Inlet Hydrocarbon Concentration
Maximum Outlet Pressure
Max Inlet Carbon Monoxide Concentration
Max Inlet Temperature
Inlet Pressure Range (regulated to 7 bar)
Inlet Port
Outlet Port
< 0.1 ppm
< 0.1 ppm
99.99%
Ambient +15 °C
100 ppm
6.5 bar
50 ppm
40 °C
4.5 – 10 bar
1/4" NPT
1/8" NPT
Specifications for Ultra Zero Air
Part No.
N9307081
N9307082
N9307083
N9307080
Outlet Ultra Zero Air
1500 mL/min
3000 mL/min
6000 mL/min
15000 mL/min
Outlet Carbon Dioxide
Concentration
< 5 ppm
< 10 ppm
< 10 ppm
< 10 ppm
Outlet Nitrogen Oxides
Concentration
< 0.1 ppm
< 1 ppm
< 1 ppm
< 1 ppm
Outlet Dewpoint
< -70 °C
< -50 °C
< -50 °C
< -50 °C
Electrical
Requirements
230/115 VAC
270 W max
230/115 VAC
270 W max
230/115 VAC
270 W max
230/115 VAC
500 W max
Description
Part No.
1.5 L/min of air (without compressor)
3.0 L/min of air (without compressor)
6.0 L/min of air (without compressor)
15.0 L/min of air (without compressor)
N9307081
N9307082
N9307083
N9307080
All models come WITHOUT a compressor.
Oil Free Compressor Required.
Order online at www.perkinelmer.com/supplies
ORDER TODAY
57
GC Quiet Compressor/High Purity Brass Regulator
PerkinElmer Ultra
Quiet Compact Oil
Free Compressor for
GC Zero and
Ultra Zero Air
Generators
PerkinElmer’s GC
Quiet Compressor
This industrial ultra quiet compact oil
free 6 gallon compressor that can be
utilized in the immediate laboratory
area for the supply of clean air.
High Purity
Brass Regulators
Key Benefits:
PerkinElmer regulators are constructed
of high-purity brass barstock and have
stainless steel diaphragms and metal-tometal seals. They are suitable for use
with high-purity (>99.995% pure) noncorrosive gases. Regulators terminate in
a 1⁄4 in. NPT Swagelock fitting.
■
Barstock body
construction
■
Stainless steel
diaphrams
■
Metal-to-metal seals
■
Use with high-purity
carrier gas
Horse Power: 0.60
Power Requirements:
115V/220V/50 – 60Hz
High-purity Brass Regulators (Dual Stage)
Output: 2.5 CFM
Key Benefits:
■
■
Ultra quiet for use in the
laboratory area
Compact size and light weight
■
Commercial / Industrial grade
■
1 Year warranty on workmanship
■
5.0 micron pre-filter and regulator
■
Internally powder coated air
tank to prevent rust
■
Max Pressure: 100 PSI
CGA
Fitting
Delivery
Pressure Use
Delivery
Pressure
Range (psig)
Cylinder
Pressure
Gauge
Guage (psig) (psig)
Part No.
Max Pressure: 7 bar
CGA-350
H2 and Ar/CH4
4 – 100
0 – 200
0 – 4000
09907128
Operating Pressure PSI: 80 – 100
CGA-580
He, Ar, N2
4 – 100
0 – 200
0 – 3000
09907127
Output: 67 L/Min
Operating Pressure Bar: 6 – 7
Noise Level: 62 db/A
High-purity Brass Regulators (Single Stage)
Tank Size: 6.0 Gal.
Tank Size Liter: 24 L
Dimensions: 16 x 16 x 20 in.
Weight: 54 lbs.
Pressure switch for automatic
operation
Packed Dimensions: 19 x 18 x 23
Packed Weight: 58 lbs.
Description
Part No.
115V
220V 60Hz
220V 50H
N9306291
N9306292
N9306293
Delivery
Pressure Use
CGA-350
CGA-350
CGA-590*
CO,H2 and Ar/CH4 Mixes 4 – 100
CO, H2
10 – 200
Air
10 – 200
GC Startup Kit
GC Startup Kit ⁄8" Tubing
and Fitting for (3) Gases
1
Description
⁄8" Tubing x 50 foot coil
Copper Special Cleaning
1
⁄8" Compression Brass
Tee Two Piece Ferrule Brass
Tee 1⁄8" Com x 1⁄8"
Comp x 1⁄4" fnpt Brass
Adjustable Safety Relief
Valve Brass 50 – 150 PSI
1
⁄4" fnpt x 1⁄8" Comp Fitting Brass
1
⁄8" Port Connector Brass
1
⁄8" Ferrule Brass
1
⁄8" Compression Brass Nut
1
⁄8" Compression Brass Fitting Cap
Tubing Cutter 1⁄8" Tubing
Teflon Tape
Cylinder
Pressure
Gauge
Guage (psig) (psig)
Part No.
0 – 150
0 – 400
0 – 400
00230091
00230253
00230090
0 – 4000
0 – 4000
0 – 4000
Part No.
N9306304
Qty
1
3
3
3
3
3
3
3
3
1
1
GC Startup Kit
GC Startup Kit 1⁄8" Tubing
and Fitting With One
Single Stage Regulator
Part No.
N9306305
Description
Qty.
⁄8" Tubing x 50 foot coil
Copper Special Cleaning
1
⁄8" Compression Brass
Tee Two Piece Ferrule Brass
Tee 1⁄8" Com x 1⁄8" Comp x 1⁄4" fnpt Brass
Adjustable Safety Relief
Valve Brass 50 – 150 PSI
1
⁄4" fnpt x 1⁄8" Comp Fitting Brass
1
⁄8" Port Connector Brass
1
⁄8" Ferrule Brass
1
⁄8" Compression Brass Nut
1
⁄8" Compression Brass Fitting Cap
Tubing Cutter 1⁄8" Tubing
Teflon Tape
Single Stage Analytical 0 – 100 psig
delivery, CGA 350 (H2,Carbon
Monoxide, Ethylene)
1
1
Delivery
Pressure
Range (psig)
CGA
Fitting
*Supplied with 590-580 Adapter.
GC Startup Kit
58
High Purity
Brass
Regulators
1
GC Startup Kit 1⁄8" Tubing
and Fitting With One
Dual Stage Regulator
Part No.
N9306306
Description
Qty.
⁄8" Tubing x 50 foot coil
Copper Special Cleaning
1
⁄8" Compression Brass
Tee Two Piece Ferrule Brass
Tee 1⁄8" Com x 1⁄8" Comp x 1⁄4" fnpt Brass
Adjustable Safety Relief
Valve Brass 50 – 150 PSI
1
⁄4" fnpt x 1⁄8" Comp Fitting Brass
1
⁄8" Port Connector Brass
1
⁄8" Ferrule Brass
1
⁄8" Compression Brass Nut
1
⁄8" Compression Brass Fitting Cap
Tubing Cutter 1⁄8" Tubing
Teflon Tape
Dual Stage Analytical 0 – 100 psig
delivery, CGA 580 (N2, Argon, He)
1
3
3
3
3
3
3
3
3
1
1
1
See page 2 for ordering information and a complete listing of PerkinElmer offices.
1
3
3
3
3
3
3
3
3
1
1
1
service plans
Dependable Service coverage to
enhance your productivity
and performance
Maximize instrument
performance and uptime
From unplanned repair expenses to lost productivity, few events
can be as disruptive as the failure of a key instrument. With a
service and support plan from PerkinElmer, your lab will be
protected from unplanned downtime and unexpected expense.
Planning for future service needs as part of your new instrument
budget proposal or purchase order will enable your laboratory to:
■
Fix the cost of ownership of mission critical or revenue
generating instrumentation
■
Ensure seamless continuation of support when the initial
12-month warranty expires
■
Eliminate administration costs incurred by continually renewing
contracts
■
Avoid having to re-justify maintenance expense at a future date
■
Make use of funds now that may not be available in the future
Call your local sales representative to learn more about the
PerkinElmer service and support products that the most
successful global corporations, research facilities and
analytic laboratories use to enhance their performance.
Three service plan options are
available to meet your needs
PerkinElmer’s range of multi-year service plans eliminates the
risk of unbudgeted service expense and ensures instrumentation is
maintained to the highest possible standard throughout its lifetime.
Comprehensive
This plan is ideal for laboratories whose financial success depends
on the consistent availability and high performance of their
scientific instruments.
Basic
This plan is ideal for medium to large laboratories that require
predictable instrument performance.
Repair
The Repair service plan is ideal for small to medium laboratories
seeking to maximize limited maintenance budgets and maintain
instrument performance.
Three Options of Service Plan Packages
PerkinElmer
Service Benefits
Comprehensive
Maximum Uptime
Basic
Managed Expense
Repair
Dependable Protection
Core Benefits
Priority On-Site Response
Preventative Maintenance
Training
PerkinElmer Certified Parts
Expert Service Engineers
Travel to your Location
Within 48 hours
2 Annual Visits
15% off
100% included
100% included
100% included
1 Annual Visit
5% off
100% included
100% included
100% included
100% included
100% included
100% included
Additional Features
Online Support Resources
Responsive Technical Support
Service History Tracking
Six Sigma & ISO Best Practices
100% included
100% included
100% included
100% included
100% included
100% included
100% included
100% included
100% included
100% included
100% included
100% included
Order online at www.perkinelmer.com/supplies
ORDER TODAY
59
PerkinElmer products —
proven quality, reliability
and results.
NEW PRODUCTS
PerkinElmer—The Clear Choice in Chromatography
Hydrogen Generators!
The newest membrane technology
for safe production of
pure hydrogen gas.
See page 56 for details.
3-Cartridge Gas
Purification System
See pages 35 for details.
Marathon
Filament for
PerkinElmer
GC/MS Systems
See page 31 for details.
Portable Gas
Leak Detector!
Compact handheld
detector with
audible alarm.
IR Temperature Gun!
Low-cost, non-contact
temperature measurement with
laser sighting.
See pages 36 for details.
See page 36 for details.
Colored Syringes with
New Blue Barrel design.
Enhanced visual sample volume verification.
SAVE 5 and 10 piece syringe packs
See pages 38 for details.
Order online at www.perkinelmer.com/supplies
008977_01
PerkinElmer, Inc.
710 Bridgeport Avenue
Shelton, CT 06484
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement