www.perkinelmer.com/supplies Chromatography Consumables and Supplies Genuine PerkinElmer Products — Genuine Value VOLUME 4 2010 – 2011 PerkinElmer—The Clear Choice in Chromatography NEW! Flexar FX-15 UHPLC System SWAFER Nitrogen Generators! Micro-Channel Wafer Technology The newest membrane technology for safe production of pure nitrogen gas. See page 30 for details. FlowMark™ Electronic Flowmeter! Compact handheld meter with data output via USB port. See page 37 for details. SAVE See page 29 for details. Thermal Desorber Tubes SVI™ Soil Vapor Intrusion™ Tubes See page 53 for details. Volume discounts available on Crimp Top Headspace Vials with write on patch and fill indicator lines See page 48 for details. Order online at www.perkinelmer.com/supplies ordering information New Investments – Local Support – Proven Quality! For over 50 years, PerkinElmer has helped our global laboratory partners meet their most demanding application measurement challenges. Our experience in Chromatography, Spectroscopy and Material Characterization gives us a unique advantage in providing holistic and comprehensive solutions for laboratories in universities and key market segments like Environmental, Energy, and Food & Product Safety. When you order our precision-designed, genuine PerkinElmer consumables and accessories, you can enjoy the peace of mind, ease of ordering, and best-in-class service. You’ll get the results you need – accurately and on time. PerkinElmer selects only the highest quality products for our consumables portfolio and invests heavily to test and validate the quality of our products. Telephone Facsimile Africa & East/Central Europe French Africa ............................33 1 64 86 28 28 Egypt & English Africa ..................202 22905306 Bulgaria ......................................359 2 952 0301 Croatia ........................................385 1 2001 767 Poland ......................................48 22 310 88 00 Romania ....................................40 21 316 2877 Latvia ..........................................371 6755 1894 Lithuania ......................................370 5 2638748 Hungary ........................................36 1 251 1116 Czech Republic ........................420 241 430 534 Slovakia ....................................421 48 4155008 Telephone Facsimile Cyprus ......................................357 22 33 82 34 Russian Federation ....................7 495 935 8888 Turkey - Ankara ........................90 312 472 6363 Turkey - Istanbul ......................90 212 212 5566 Israel ..........................................972-3-9777000 Malta ..........................................356 21 344 345 Portugal ..................................351 21 782 60 30 Greece - Hellas..........................30 2310 322525 Greece - Athens ......................30 210 779 5980 Iceland ..........................................354 568 8533 357 22 33 82 32 7 495 564 8787 90 312 472 6313 90 212 212 2829 972-3-9777001 356 21 343 952 351 21 782 60 39 30 2310 321912 30 21 771 6932 354 568 0304 Export Territories 33 1 69 07 69 54 202 22905307 359 2 952 3784 385 1 2001 724 48 22 310 88 01 40 21 316 2876 371 6755 1976 370 5 2638749 36 1 251 1461 420 241 430 535 421 48 2301628 Middle East Americas Argentina ..................................54 11 4554 4004 Brazil ........................................55 11 3868 6200 Canada ....................................905-851-4585 or 800-561-4646 Chile ............................................56 2 784 7500 Mexico......................................52 55 5337 0700 Puerto Rico....................................787 783 3067 United States............................203-925-4600 or 800 762-4000 Central America........................52 55 5337 0700 54 11 4554 2807 55 11 3868 6210 905-851-1814 56 2 269 8070 52 55 559 36223 787 793 7198 203-944-4904 52 55 559 36223 Asia Australia ................................61-3-9212-8500 or 1-800 033 391 China - Shanghai ......................86-21-38769510 China - Beijing ..........................86-10-58208166 China - Chengdu ................86-28-8678 2887 or 86-28-8678 2662 or 86-28-86783530 China - Wuhan ....................86-27-8732-2732 or 86-27-8732-2756 or 86-27-8732- 2826 China - Shenyang....................86-24-2256-6158 China - Guangzhou ................86-20-8363 3179 Hong Kong..................................852-2620-1881 India - Mumbai ..........................022- 6760 1700 Indonesia ............................62-21-55960245-48 Japan - Yokahama ....................81-45-339-5861 Japan - Osaka ..........................81-6-6386-6004 Japan - Kyushu ........................81-92-473-7001 Japan - Tokyo............................81-3-3866-2647 Korea ............................................82 2 868 5350 Malaysia ...................................... 603-79491118 New Zealand ..........................64-21-751-007 or 0800 776 767 Philippines................................(+63-2) 637 0180 Singapore ......................................65-67799555 Taiwan - Taipei ..........................886-2-27647199 Taiwan - Kaohsiung ....................886-7-5521030 Thailand..........................................662-3197901 Vietnam - Hanoi ..........................(84) 4 7472259 Vietnam - Ho Chi Minh City ........(84) 8 8394155 2 61-3-9212-8595 86-21-50791316 86-10-58208155 86-28-8678 2522 86-27-8732-2685 86-24-2256-6153 86-20-8363 3579 852-2620-1238 022 - 6760 1791 62-21-55960167 81-45-339-5871 81-6-6386-7009 81-92-473-8353 81-3-3866-2652 82 2 868 4343 603-79491119 64-9-966-2955 or 0800 776 000 (+63-2) 910 1168 65-68726595 886-2-27647209 886-7-05543402 662-3197900 (84) 4 7472260 Bahrain ......................................971 4 883 0233 Kingdom of Saudi Arabia - Central ....................................................966 1 4793000 Kingdom of Saudi Arabia - East ....................................................966 3 8475299 Kingdom of Saudi Arabia - West ....................................................966 2 6720888 Kuwait ........................................965 246 10 480 Oman ......................................968 248 14752 or 99269420 Pakistan ..................................92 21 5345581 or 5340747 or 52417934 or 53460578 Qatar ..............................................974 4654563 Republic of South Africa ............27 11 794 4430 United Arab Emirates ................971 4 883 0233 Yemen............................................967 234 5073 971 4 883 0133 966 1 4771374 966 3 8475296 966 2 6725664 965 246 10 488/9 968 248 13924 92 21 5345582 974 4652256 27 11 794 2160 971 4 883 0133 967 234 0504 Western Europe Austria ..........................................0800 111 933 Belgium ............................................0800 40858 Denmark ..........................................80 88 42 36 Estonia..........................................372 7 383 330 Finland ....................................358 (0)2 267 8111 France............................................0805 111 333 Germany....................................0800 1 81 00 32 Italy..............................................800 906 642 or 39 039 2383-1 Luxembourg......................................0800 26588 Netherlands ..................................0800 0234490 Norway ..............................................800 18 854 Republic of Ireland ........................1800 932 886 Spain ..........................................918 061 200 or 800 099 164 Sweden..........................................0200 887 520 Switzerland ....................................0800 000 015 United Kingdom ..........................0800-89 60 46 0800 111 934 0800 40859 80 88 42 37 372 7 383 360 358 (0)2 267 8599 0805 111 334 0800 0 00 66 79 39 039 2383 490 0800 26589 0800 0234491 800 18 855 1800 932 884 918 040 414 or 800 099 165 0200 887 521 0800 000 016 0800-89 17 14 See page 2 for ordering information and a complete listing of PerkinElmer offices. Table of Contents Liquid Chromatography Order Online Place your order online at: www.perkinelmer.com/supplies NEW Flexar Series UHPLC System . . . . . . . . . . . . . . . . 4–7 Online ordering is currently available in Australia, Austria, Belgium, Canada, Denmark, Finland, France, Germany, Ireland, Italy, Luxemburg, the Netherlands, Norway, Puerto Rico, Spain, Sweden, Switzerland, the United Kingdom and the United States. NEW Flexar Autosampler and Accessories . . . . . . . . 8–11 Order by Phone, Fax or E-mail Cartridge Columns . . . . . . . . . . . . . . . . . . . . . . . . . . 16–21 Please contact your local PerkinElmer Customer Care Representative. See local office listings to the left. Or visit www.perkinelmer.com/lasoffices. Sample Loops Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Order by Mail HPLC Pump Accessories. . . . . . . . . . . . . . . . . . . . . . 24–26 Visit us online at www.perkinelmer.com/lasoffices to obtain the correct address for mailing your company Purchase Order. Flow Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Conventional Columns . . . . . . . . . . . . . . . . . . . . . . . 12–15 Fingertight® Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Detector Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Return Goods Policy Before returning any item to PerkinElmer, please obtain a Return Authorization Number from a customer service representative. Call your local PerkinElmer office and please have the following information ready: 22 Gas Chromatography Clarus 600 GC and GC/MS . . . . . . . . . . . . . . . . . . . . 30–31 Our Order Number or your Purchase Order Number ■ The PerkinElmer part numbers of the items that you wish to return GC Organic Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ■ Reason for return Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33–35 28 Leak Detector and IR Temperature Gun. . . . . . . . . . . . . 36 Flowmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 32 Ferrules, Syringes and Liners. . . . . . . . . . . . . . . . . . 38–39 Technical Support Vials, Caps and Septa . . . . . . . . . . . . . . . . . . . . . . . . 40–41 For technical assistance, please contact your local PerkinElmer Customer Care Representative. See local office listings to the left. Elite Series Capillary Columns . . . . . . . . . . . . . . . . . 42–44 Check with your local PerkinElmer Customer Care center for current pricing. PerkinElmer and the PerkinElmer logo are registered trademarks of PerkinElmer, Inc. All other product and company names mentioned herein may be the trademarks or registered trademarks of their respective owners. PerkinElmer is not responsible for typographical or photographic errors that may appear in this catalog. We reserve the right to make adjustments or corrections due to changing market conditions, product discontinuations, or typographical or photographic errors in advertisements or product descriptions. Terms and conditions and item availability are subject to change without notice. 16 Nitrogen Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 ■ Our customer service representative will provide you with a Return Authorization Number and the return address. We cannot accept any returns without a Return Authorization Number. Policy may vary. Please contact your local PerkinElmer representative for details. 6 table of contents Ordering Information Applications Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 38 Headspace/Traps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Headspace Vials and Caps . . . . . . . . . . . . . . . . . . . . 47–51 Packed Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 49 Thermal Desorption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Air Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56–57 For details on our terms and conditions, including warranties, please visit: www.perkinelmer.com/terms Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 54 One Source Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Order online at www.perkinelmer.com/supplies ORDER TODAY 3 Flexar UHPC Power and Flexibility in UHPLC FX-15 ULTRA HIGH PERFORMANCE LC 18,000 PSI FX-10 ULTRA HIGH PERFORMANCE LC 10,000 PSI PERFORMANCE LC CONVENTIONAL LC 6,000 PSI LC CONVENTIONAL LC MANUAL INJECTION PRODUCTIVITY New Flexar™ UHPLC System from PerkinElmer With Flexar UHPLC, you'll be able to transfer your existing methods to achieve faster, more predictable results while reducing your solvent consumption by up to 90%. The FX-15's patented, dual reciprocating, 18,000 psi pump offers the widest operating range with exceptional compositional accuracy and retention time repeatability. The value and performance of the FX-10 microbinary pump offers minimal disruption in your method development phase and analytical approach so you can easily port your existing methods. And with the powerfully easy new Chromera® software, instrument control is taken to a whole new level. Performance, flexibility and predictability — Flexar. Flexar UHPLC Systems Description Part No. Flexar FX-10 UHPLC Platform Flexar FX-10 UHPLC Pump Flexar FX-10 UHP Pump Master "Flexar Bottle Manager, 3-channel Vacuum Degassing" tubing kit NFLR0210 N2910640 N2910641 N2600581 Flexar UHPLC Systems 4 Benefits of Flexar UHPLC: Description Part No. ■ Improved separation efficiency ■ Up to 90% reduction in solvent consumption — saving you money Flexar FX-15 UHPLC Platform Flexar FX-15 UHPLC Pump "Flexar Bottle Manager, 3-channel Vacuum Degassing" tubing kit NFLR0215 N2910531 N2600581 ■ Up to 10x productivity gains — helping you do more in less time See page 2 for ordering information and a complete listing of PerkinElmer offices. The Powerfully Easy CDS One click and you’ll see: CDS doesn’t get any easier than Chromera. Combining intuitive ease of use with powerful functionality and configurability, Chromera delivers the most streamlined way to get from the analysis you need to the information your enterprise demands. It’s powerfully easy. Information-rich Desktop offers instrument control at-a-glance Chromatography Data System Chromera® Chromatography Data System Features and Benefits: Powerful Easy ■ Instrument Control: NEW patented “Device Descriptors” control instruments. No channels limitation, trackable instrument status ■ Shallow footprint GUI: Most functions only one or two clicks away, using familiar Microsoft™ Outlook user interface ■ Designed for UHPLC: interactive graphical methods optimization environment with immediate feedback; ability to overlay pressure profile run after run. Extend runtime of chromatogram in real time ■ ■ Graphics: Multichannel graphics for multiple signal channel monitoring (including system status channels to get ‘the pulse of the system’ real-time) Simple and obvious method editor: a single-point access to all instrument parameters, regardless of how complex the instrument configuration; Convenient tools for point-and-click method optimization ■ Intuitive Sequence Wizard: Create complex sample tables easily; Convenient auto-fill and other editing functions; Decision Points for real-time and post-processing data evaluation ■ Feedback: Instrument-at-a-glance status panel provides real-time feedback of complete LC system ■ ■ Batch Sequencing: all the functions for setting up and reviewing a sequence and results are within a single environment Peak Integration Wizard: Makes integration process easy and straight forward ■ Report Wizard: allows creating numerous styles of reports and printouts using the same tool Order online at www.perkinelmer.com/supplies ORDER TODAY 5 Flexar FX UHPLC Flexar UHPLC Systems... you don’t have to pay more to achieve so much FX-10 UHPLC System FX-15 UHPLC System FX-10: High Value UHPLC 6 ■ Micro Binary 10,000 psi pump package ■ High efficiency FX UHPLC autosampler ■ Column oven for retention time reproducibility and viscosity reduction ■ High speed FX UV/VIS detector (100 pt/sec) with high efficiency 2.4μL flow cell ■ Straightforward method transfer to UHPLC FX-15: Ultimate in UHPLC ■ Dual reciprocating 18,000 psi pump with exceptional compositional accuracy, retention time reproducibility and automatic piston wash ■ High efficiency FX UHPLC autosampler ■ Column oven for retention time reproducibility and viscosity reduction ■ High speed FX UV/VIS detector (100 pt/sec) with high efficiency 2.4μL flow cell See page 2 for ordering information and a complete listing of PerkinElmer offices. PerkinElmer syringe kits for high pressure applications are manufactured for precise liquid delivery. All of these glass syringes come with precision stainless steel plungers. They are used for sampling and flushing and are available in a large variety of sizes. The 250 μL syringe comes standard with both the Series 225 and Series 275 Autosamplers. Interferene Syringe KitsCheck Standards Description Part No. 100 μL w/ 200 μL Buffer Tubing 250 μL w/ 500 μL Buffer Tubing 500 μL w/ 1,000 μL Buffer Tubing 1000 μL w/ 2,000 μL Buffer Tubing 2500 μL w/ 2,000 μL Buffer Tubing N2936051 N2936052 N2936053 N2936054 N2936055 Interferene Check Standards Syringes Description Part No. Sample Needle w/ fittings Air Guide Needle (62 mm) Bio Compatible Sample Needle w/tubing Connector Needle (80 mm) N2936009 N2936000 N2936010 N2936342 Interferene FX-15 UHPLC Check PumpStandards Accessories Description Part No. Replacement 0.5 μm filter frits for FX-15 (4-pack) High pressure FX-15 piston seal kit Piston wash bottle kit N2911224 N2911221 N2601616 FX-10 Interferene & FX-15 Check UHPLC Standards System Accessories Description Part No. 0.005” ID PEEK tubing (blk), 50 cm 0.004” ID PEEK tubing (red), 50 cm Connector tubing, Flexar iso/binary/quaternary pump to autosampler, SS Connector tubing, dual mixer connection (≤250 μL), SS Connector tubing, dual mixer connection (³350 μL), SS Connector tubing, FX-10 pump A (upper) to T-mixer, SS Connector tubing, FX-10 pump B (lower) to T-mixer, SS Connector tubing, FX-10 purge valve to filter/scavenger, SS Connector tubing, FX-10 injector to column, SS Connector tubing, FX-10 pump A (upper) to dual mixers, SS Connector tubing, FX-10 pump B (lower) to dual mixers, SS Connector tubing, FX-15 pump to in-line mixer, SS Connector tubing, FX-15 pump to dual mixers, SS Connector tubing, FX-15 injector to column, std, SS Connector tubing, FX-15 injector to column, 33 cm, SS 3cmm scavenger cartridge holder Spheri5 scavenger columns (5-pack) N2916200 N2916059 N2916210 N2916216 N2916217 N2916213 N2916214 N2916212 N2916215 N2916218 N2916219 N2916222 N2916224 N2916223 N2916201 02580178 02580202 Microsyringes (For Manual Injection) Syringes are used for accurate and precise liquid delivery. Each syringe is hand-fitted to assure maximum accuracy. Our syringes are composed of glass barrels and precision stainless steel needles. The needle features a blunt tip, required for use with a Rheodyne injector. Flexar UHPLC System Accessories High Pressure Static Mixers Static Mixers are important in facilitating complete mobile phase blending, resulting in improved retention performance. These mixers should be used as part of Series 275, FX10, or FX15 LC systems, where high pressure blending is required. Mixers incorporate a highly efficient cross-flow shearing mechanism which produces vortex sheer mixing over a wide range of volumes. They are now offered in 18,000 psi pressure max flavor. Flexar Accessories Syringes and Kits A good first choice selection is a volume of about half the flow rate volume. For example, when pumping at a 0.5 mL/min flow rate, a 350 μL mixer provides good mixing with very good baseline stability. Interferene High Pressure Check Analytical Standards Static Mixers Description Part No. 50 μL In-Line High Pressure Mixer Assembly, SS 150 μL In-Line High Pressure Mixer Assembly, SS 250 μL In-Line High Pressure Mixer Assembly, SS 350 μL In-Line High Pressure Mixer Assembly, SS 500 μL In-Line High Pressure Mixer Assembly, SS 150 μL High Pressure Binary High Pressure Mixing-T, SS 10 μL Binary Mixing-T, SS Binary high pressure T-Mixer, SS, 50 uL Binary high pressure T-Mixer, SS, 350 uL Binary high pressure T-Mixer, SS, 500 uL T-connector, SS N2911200 N2911201 N2911202 N2911205 N2911203 N2911206 N2911170 N2911212 N2911210 N2911211 N2911127 Solvent and Sample Filtration Syringe filters are important for high pressure applications of effectively filter samples to prevent premature column performance loss and possible flow restriction of the narrow tubing that is typically required for high pressure LC applications. Interferene Syringe Filters Check Standards Description PVDR 13 mm Filter (pkg. 100) Nylon 17 mm Filter (pkg. 100) Nylon 17 mm Filter (pkg. 100) Nylon 30 mm Filter (pkg. 100) Nylon 30 mm Filter (pkg. 100) PTFE 17 mm Filter (pkg. 100) PTFE 30 mm Filter (pkg. 100) PTFE 30 mm Filter (pkg. 100) Pore Size Part No. 0.45 μm 0.45 μm 0.20 μm 0.45 μm 0.20 μm 0.20 μm 0.45 μm 0.20 μm 02542783 02542880 02542881 02542882 02542883 02542884 02542885 02542886 Interferene Check Microsyringes (ForStandards Manual Injection) Description Part No. 10 μL Syringe 25 μL Syringe 50 μL Syringe 100 μL Syringe Rheodyne 22-gauge Blunt Needle with Luer Hub 09904937 09904823 09904941 09904822 09904943 Interferene Syringes Disposable Check Standards Description Part No. Disposable Syringes, Luer-Lock Tips, 1 mL Disposable Syringes, Luer-Lock Tips, 3 mL 02542890 02542891 Order online at www.perkinelmer.com/supplies ORDER TODAY 7 Flexar Autosamplers and Inject with Greater precision Best-in-class cycle time. Wide injection volume range. Excellent injection reproducibility. Precisely what you need to increase your sample throughput and efficiency. Flexar or Series 225/275 Autosampler Trays Description Part No. 25-Position 6 mL Vial Sample Tray N2936045 80-Position 2 mL Vial plus (5) 6 mL Vial Tray (for derivatization) N2936046 80-Position 2 mL Vial Tray with Dilution Tray N2930676 96-well Microtiter N9302562 96-well ‘Deep-well’ Microtiter N9302560 96-well 7 mm Pre-slit Silicone Plate mat/Seal N9302555 96-well ‘Shallow’ Microtiter Plate Adaptor (supports dual microtiter plates) N2936048 96-well ‘Deep’ Microtiter Plate Adaptor (supports dual microtiter plates) N2936049 100-Position 2 mL Vial Sample Tray N2936042 (200) 0.2 mL Microvial plus (5) 2 mL Vial Tray N2936043 ■ Injects sample volumes as little as 1 μL at pressures up to 18,000 psi with the FX UHPLC Autosampler ■ Loads sample in only 8 seconds (in partial fill mode) ■ Three injection modes: full loop, partial fill and μL-pickup with no sample waste ■ Peltier cooling/heating mode option for operation at 4 °C to 40 °C. Will reach 4 °C ± 2 °C, achievable even at ambient temperatures up to 25 °C. All Flexar autosamplers can be upgraded in the field for Peltier cooling and heating. All Flexar autosamplers include: ■ 100sample tray ■ 100 2mL vials ■ 100 2mL screw top cap with cross slit vial septum ■ Tubing to connect to waste reservoir ■ All cables required for connection to a TotalChrom or Chromera Operating Environment ■ I/O cable (Pump Start / ReadyIn) ■ Service Manager SW CD ■ Userʼs Manual ■ Nuts and ferrules ■ All fuses for 120–240 V Flexar Autosamplers and Upgrade Kits Flexar LC Autosampler Description Part No. High throughput autosampler with exceptionally low carryover. Operates up to 6100 psi (420 bar). Provides flexible injection modes: full-loop, partial-fill and μL-Pickup (no sample waste). Peltier cooling and heating options available as field upgrades. Comes standard with 100 μL loop and 250 μL sample flush syringe. N2930660 Flexar Peltier LC Autosampler Description High throughput autosampler with exceptionally low carryover. Operates up to 6100 psi (420 bar). Provides flexible injection modes: full-loop, partial-fill and μL-Pickup (no sample waste). Built-in Peltier cooling comes standard. Peltier heating option available as field upgrade. Comes standard with 100 μL loop and 250 μL sample flush syringe. Part No. N2930661 Flexar FX UHPLC Autosampler Description High throughput UHPLC autosampler with exceptionally low carryover. Operates up to 18,000 psi (1,241 bar). Provides flexible injection modes: full-loop, partial-fill and μL-Pickup (no sample waste). Built-in Peltier cooling comes standard. Peltier heating option available as field upgrade. Comes standard with 10 μL loop and 250 μL sample flush syringe. Part No. N2930664 Field Upgrade Peltier Kits Description Flexar and Series 225 Upgrade Kit (from standard to Peltier Cooling option) Flexar and Series 225 Upgrade Kit (from standard to Peltier Cooling and Heating option) Flexar and Series 225 Upgrade Kit (from Peltier Cooling to Peltier Cooling and Heating option) 8 See page 2 for ordering information and a complete listing of PerkinElmer offices. Part No. N2930672 N2930673 N2930669 Accessories Vials, Caps and Septa Kits from PerkinElmer PerkinElmer Supplies – Tested and Approved We have expanded our product selection to include additional vial types, new version caps and mating septa in a kit format for easier customer ordering. This reference guide contains both current and new product information. Tested to mmet your application requirements andguaranteed for fit and compatibility. LC Vials, Caps and Septa PerkinElmer offers a variety of vials, caps and septa to fulfill your application needs. Our screw thread vial caps use the revolutionary Inter-Seal®. Using a process that bonds silicone/PTFE and other elastomeric compounds directly into thermoplastic closures eliminates liner fallout, while still providing the excellent resealability and multiple injection capability. No adhesives are used in many markets including: environmental, diagnostic packaging, pharmaceutical packaging, cosmetic and food packaging. 2.0 mL Vials, Caps and Septa Vials* Description 2 mL 11 mm Clear Glass Crimp Vials 2 mL 11 mm Amber Glass Crimp Vials 2 mL 11 mm Clear Snap Top Vial 2 mL 11 mm Clear Snap Wide Opening Vials with Write-On Patch and Fill Lines 2 mL 11 mm Amber Snap Wide Opening Vials with Write-On Patch and Fill Lines 2 mL 10 mm Clear Glass Screw Top Vials with Write-On Label and Fill Lines 2 mL 10 mm Amber Glass Screw Top Vials with Write-On Label and Fill Lines 2 mL 10 mm Screw Top Vial Caps, Black Polypropylene with PTFE/Slit White Silicone 2 mL 9 mm Clear Screw Top Vial 2 mL 9 mm Amber Glass Screw Top Vial Pkg 100 100 100 100 Part No. N9301385 N9302680 N9303418 N9306207 100 N9306208 100 N9306053 100 N9306057 100 N9306052 Caps/Septa: 100 100 N9306201 N9306220 Description Pkg Part No. 8 mm Silver Aluminum Crimp Cap PTFE/Rubber PTFE/Pre-Slit White Silicone Polyethylene Press-On Cross-Slit Cap for 8 mm Vials 1000 1000 03300806 N9302141 Pkg 1000 Part No. 04978532 Description Pkg Part No. 1000 N9307023 Glass Microvials, Tapered, 0.2 mL, 8 mm o.d. Top* 500 N9302136 100 N9306052 100 N9306205 Description Pkg Part No. 25 N9307027 100 N9302684 12 x 32 Glass Vial Support Sleeve for 2 mL 8 mm Micro Vials (N9302136) 100 N9302685 100 N9302686 Description Pkg Part No. 500 N9306080 N9306015 Polyethylene Includes 300 μL Tapered Vial, Blue Polypropylene Cap with Bonded Silicone/PTFE Septa Caps/Septa* Description 11 mm Snap Cap Polyethylene Cross-cut Slit (no Septum) 11 mm Snap Cap Polyethylene Single Slit (no Septum) 10 mm PTFE/Silicone Single Slit Screw Cap Black 10 mm PTFE/Silicone No Slit Screw Cap Black 11 mm Crimp Green Aluminum Cap w/Teflon® Rubber Septa 11 mm Crimp Red Aluminum Cap w/Teflon® Rubber Septa 11 mm Crimp Blue Aluminum Cap w/Teflon® Rubber Septa 11 mm Crimp Silver Aluminum Cap w/Teflon® Rubber Septa 100 * Also see Convenience Kits for additional vials and caps sold separately. 0.2 mL Micro Vials, Caps and Septa Crimp Top Vials: Autosampler Vial Sleeve: Micro Vial Kit: * To be used with Glass Vial Support Sleeve (N9307227). Order online at www.perkinelmer.com/supplies ORDER TODAY 9 Flexar Autosampler Vials, Caps and Septa Kits from PerkinElmer Autosampler Vial Glass Inserts Vial Glass Inserts: Kits for your LC Autosampler Description Autosampler Vial Starter Kits Complete and convenient starter kits for your volatile and standard applications. Each kit contains everything you need to run your LC instruments under two convenient part numbers. Each kit contains syringes, vials, caps and a vial rack. Description Pkg. LC Screw top Starter Kit: 30 mL Pump Priming Syringes Racks for 50 12 mm Vials Polypropylene Screw Caps PTFE/Silicone (Pkg/100) 2 mL 10 mm Screw Top Vials w/Label and Fill Lines (Pkg/100) 2 mL 10 mm Screw Top Amber Vials w/Label and Fill Lines (Pkg/100) 25 μL Blunt Syringes 1 ⁄16 Union Tubes Nut and Ferrules (Pkg/6) LC Crimp top Starter Kit: Crimper Tool (Manual) Racks for 50 12 mm Vials 2 mL 11 mm Crimp Top Vials (Pkg/100) 2 mL 11 mm Crimp Top Amber Vials (Pkg/100) 25 μL Blunt Syringes 11 mm De-capper Tool (Manual) 11 mm Silver Crimp Top Caps w/Septa (Pkg/100) Part No. 3 2 4 N2930366 09904849 N9301303 N9306052 2 N9306053 2 N9306057 2 2 1 09904823 09903289 02540274 N2930365 00090699 N9301303 N9301385 N9302680 09904823 N9301390 N9306015 1 2 3 1 1 1 4 Syringe Filters N9300703 N9300704 N9306057 N9306053 N9303418 N9306231 N9306220 N9306201 N9300705 N9300706 N9302680 N9301385 N9302945 6 mL Vials and Caps Description Pkg. Part No. 6 mL Glass Large-Volume Vials with 20 mm o.d. Top Polyethylene Press-On Slit Caps/Septa or 20 mm o.d. Top Vials 125 N9302134 25 N2936083 100 100 100 100 100 100 100 100 0.45 μm 0.45 μm 0.20 μm 0.45 μm 0.20 μm 0.20 μm 0.45 μm 0.45 μm 02542783 02542880 02542881 02542882 02542883 02542884 02542885 02542886 Description Pkg. Part No. Polyethlene Micro Vial Kit – Pkg/500 Includes: 300 L Tapered Screw Top Vials (Pkg/500) Blue Polypropylene 9 mm Caps w/Bonded Silicone/PTFE Septa (Pkg/500) 1.5 mL Polypropylene Screw Top Amber Vial With Fill Lines, Teflon®/ Silicone Septa and Cap With Single Slit 1.5 mL Polypropylene Screw Top Clear Vial With Fill Lines,Teflon®/ Silicone Septa and Cap With Single Slit 500 N9306080 100 N9301735 100 N9301736 Additional pore sizes are available on the PerkinElmer website. 10 Part No. Micro Vial Kit and Polypropylene Vial/Cap Kits Syringe filters are important for high-pressure applications to effectively filter samples to prevent prem ature columnperformance loss and possible flow restriction of the narrow tubing. Description Pkg. Pore Size Part No. PVDR 13 mm Filter Nylon 17 mm Filter Nylon 17 mm Filter Nylon 30 mm Filter Nylon 30 mm Filter PTFE 17 mm Filter PTFE 30 mm Filter PTFE 30 mm Filter Pkg. 6 mm x 29 mm Clear Glass Insert, 100 Rimless Pulled Point with Bottom Spring, 250 μL Usable Volume 6 mm x 31 mm Clear Glass Flat Bottom Insert, 100 400 μL Usable Volume Use with: 10 mm 2 mL Amber Screw Top Vial w/White “P” Icon w/Patch 10 mm 2 mL Clear Screw Top Vial w/White “P” Icon w/Patch 11 mm Clear Large Opening Snap Ring Vial w/Black “P” Icon 11 mm Clear Large Opening Crimp Vial w/Black “P” Icon 9 mm 2 mL Amber Screw Top Vial w/Black “P” Icon 9 mm 2 mL Clear Screw Top Vial w/Black “P” Icon 5 mm x 29 mm Clear Glass Insert, 100 Rimless Pulled Point with Bottom Spring, 150 μL Usable Volume 5 mm x 31 mm Clear Glass Flat Bottom Insert, 100 200 μL Usable Volume Use with: 11 mm Standard Amber Crimp Vial w/Black “P” Icon 11 mm Standard Clear Crimp Vial w/Black “P” Icon 8 mm 2 mL Clear Screw Top Vial w/Black “P” Icon See page 2 for ordering information and a complete listing of PerkinElmer offices. Easy-to-order Convenience Kits (Vials and Caps/Septa also Sold Separately) Description Pkg. Part No. ™ 100 N9300707 ™ 100 N9300708 9 mm Pre-Slit PTFE/Silicone Screw Cap Convenience Kit – Pkg/100: 9 mm Pre-Slit PTFE/Silicone Screw Cap Assembly (Pkg/100) 9 mm 2 mL Clear Screw Vial Kit (Pkg/100) 1 1 N9300701 N9306203 N9306201 9 mm Red Rubber Screw Cap Convenience Kit – Pkg/100: 9 mm Red Rubber/Screw Cap Assembly (Pkg/100) 9 mm Clear 2 mL Vial Kit (Pkg/100) 1 1 N9300699 N9306200 N9306201 9 mm PTFE/Silicone Screw Cap Convenience Kit – Pkg/100: 9 mm PTFE/Silicone Screw Cap Assembly (Pkg/100) 9 mm Clear 2 mL Vial Kit (Pkg/100) 1 1 N9300700 N9306202 N9306201 11 mm Pre-Slit PTFE/Silicone Snap Convenience Kit – Pkg/100: 11 mm Pre-Slit PTFE/Silicone Snap Cap Assembly (Pkg/100) 11 mm 2 mL Clear Snap Vial Kit (Pkg/100) 1 1 N9300697 N9303416 N9303418 11 mm PTFE/Silicone/PTFE Snap Convenience Kit – Pkg/100: 11 mm PTFE/Silicone/PTFE Snap Cap Assembly (Pkg/100) 11 mm 2 mL Clear Snap Vial Kit (Pkg/100) 1 1 N9300698 N9303417 N9303418 10 mm Clear Pre-Slit PTFE/Silicone Screw Cap Convenience Kit – Pkg/100: 10 mm Pre-Slit PTFE/Silicone Screw Cap Assembly (Pkg/100) 10 mm 2 mL Clear Screw Vials with Write-On Patch and Fill Lines (Pkg/100) 1 1 N9300695 N9306052 N9306053 10 mm Amber Pre-Slit PTFE/Silicone Screw Cap Convenience Kit – Pkg/100: 10 mm Pre-Slit PTFE/Silicone Screw Cap Assembly (Pkg/100) 10 mm Amber Screw Top Vials with Write-On Patch and Fill Lines (Pkg/100) 1 1 N9300696 N9306052 N9306057 11 mm PTFE/Silicone Snap Convenience Kit – Pkg/100: 11 mm PTFE/Silicone Snap Cap Assembly (Pkg/100) 11 mm 2 mL Clear Snap Vial Kit (Pkg/100) 1 1 N9300702 N9303419 N9303418 11 mm Red Rubber Crimp Convenience Kit – Pkg/100: 11 mm Red Rubber/Silver Crimp Assembly (Pkg /100) 11 mm 2 mL Clear Vial Kit (Pkg/100) 1 1 N9300502 N9306230 N9306231 11 mm Red Rubber Crimp Convenience Kit – Pkg/500: 11 mm Red Rubber/Silver Crimp Assembly (Pkg/100) 11 mm 2 mL Clear Vial Kit (Pkg/100) 5 5 N9300503 N9306230 N9306231 11 mm PTFE/Silicone Crimp Convenience Kit – Pkg/100: 11 mm PTFE/Silicone Crimp Assembly (Pkg/100) 11 mm 2 mL Clear Vial Kit (Pkg/100) 1 1 N9300500 N9306228 N9306231 11 mm PTFE/Silicone/PTFE Crimp Convenience Kit – Pkg/100: 11 mm PTFE/Silicone/PTFE Crimp Assembly (Pkg/100) 11 mm 2 mL Clear Vial Kit (Pkg/100) 1 1 N9300501 N9306229 N9306231 Certified LC Clean Non-Slit Cap/ViaL Convenience Kit – Pkg/100: 9 mm 2 mL Screw Top Vial with 9 mm Blue Screw Top Cap Clear Non-Slit PTFE/Silicone (LC Clean™) Certified LC Clean Pre-Slit Cap/ViaL Convenience Kit – Pkg/100: 9 mm 2 mL Screw Top Vial with 9 mm Gray Screw Top Cap Clear Pre-Slit PTFE/Silicone (LC Clean™) Liquid Chromatography Laboratory Bottle Kits Description Part No. 1x5 Liter Bottle with Cap and Teflon Insert, 2 Meters PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit 1x2 Liter Bottle with Cap and Teflon Insert, 1 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit 1x1 Liter Bottle with Cap and Teflon Insert, 1 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit 1x0.5 Liter Bottle with Cap and Teflon Insert, 1 Meter PTFE 1⁄16” Tubing and 1x40 μm SS Solvent Frit 1 Cap with Teflon Insert, 1 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit 1 Cap with Teflon Insert, 1 Meter PTFE 1⁄16” Tubing and 1x40 μm SS Solvent Frit 1x0.5 Liter Bottle with Cap and Dual Teflon Insert, 2 pcs of 2 Meter PTFE 1⁄8” Tubing (Piston Wash Function) 1 Cap with Dual Teflon Insert, 2 pcs of 2 Meter PTFE 1⁄8” Tubing and 1x10 μm SS Solvent Frit (Piston Wash Function) N2601610 N2601611 N2601612 N2601613 N2601614 N2601615 N2601616 N2601617 Order online at www.perkinelmer.com/supplies ORDER TODAY 11 Brownlee Conventional Columns from Which Column Do I Need? Brownlee Brownlee Brownlee Brownlee Analytical Aquapore® Bio CHOICE™ Brownlee pH-ex C18 Brownlee Spheri-5® Brownlee Validated™ Having the right stationary phase for your separation is the first step in selecting the appropriate column. This should be based on sample solubility and on chemical differences among the sample compounds. Depending on the mode of separation you will use, PerkinElmer has the right column for you. In reversed-phase separations, the mobile phase is more polar than the stationary phase. Sample hydrophobicity also is a major determinant of the separation mode. In reversed-phase separations, the mobile phase is more polar than the stationary phase, which is traditionally a straight alkyl chain, most often C18. The majority of HPLC analyses are performed in reversed-phase mode, due to the fact that the analytes of interest can be dissolved in water, or mixtures of water and a polar organic solvent such as methanol or acetonitrile. In normal phase separations, the mobile phase is less polar than the stationary phase. Cyano phases are commonly used in either reversed-phase or normal-phase mode. A stationary phase incorporating both polar and nonpolar functionality can be used in either reversed-phase or normal-phase mode. Brownlee Analytical PerkinElmer’s all-purpose HPLC column line for conventional as well as high-speed LC separations. The Brownlee Analytical family is available in 3 or 5 μ, and lengths ranging from 30 – 250 mm, in 2.1 mm and 4.6 mm i.d. Brownlee Aquapore ® Brownlee Validated ™ These columns are made on high-purity Type B silica with inherent low silanophilic activity. They exhibit excellent peak shape for a wide range of compounds, while also having a wide number of phases. Columns are available in 3 or 5 μ, and lengths ranging from 30 – 250 mm, in 2.1 mm or 4.6 mm i.d. Brownlee Columns for HRes ™ Fast-LC Recent developments in LC column technology have now made the use of sub 3 μm particle packing materials practical. These smaller particle size materials allow higher mobile phase linear velocities to be used, without the decrease in separation efficiency experienced with conventional larger particle size packings. This translates into higher throughput and higher productivity. To conserve mobile phase, these sub 3 μm column materials are typically packed into 2.1 mm i.d. columns so that flow rates (mobile phase volume) are kept low. However, smaller sized packings result in elevated operating pressures. Technological advances in pump and injector designs have also kept pace, and these columns can be used at pressures as high as 10,000 psi with the PerkinElmer Series 275 or up to 15,000 psi using FX15 LC systems. The rugged construction of this new line of small particle columns for high pressure application yield excellent longevity and reproducibility. These packings exhibit an exceptionally tight particle size distribution for excellent resolving power and are packed at elevated pressures to assure column stability even at high pressure applications. Each column is tested to ensure the highest level of quality and efficiency in high pressure LC testing. Features and Benefits ■ Sub 3 μm particle technology and 2.1 mm i.d. for higher separation efficiency ■ Packed to withstand higher operating pressures ■ Wide choice of stationary phases This is a wide-pore silica-based support suitable for the separation of large biopolymers. Brownlee Bio Wide-pore silica that is excellent for peptide and protein separation. Columns are available in 5 μ, and lengths ranging from 30 – 250 mm, in 2.1 mm and 4.6 mm i.d. Brownlee CHOICE ™ This line of columns is made of 60 Å silica which results in large surface area, high carbon loads and high retention compounds. Columns are available in 3 or 5 μ, and lengths ranging from 30 – 250 mm, in 2.1 mm and 4.6 mm i.d. Brownlee pH-ex C18 Brownlee pH-ex C18, HPLC columns utilize a patented polycarbosilane barrier layer that protects the silica particles from extremely basic conditions. This layer uses multiple attachment points to the silica particle which yields a modified surface with enhanced stability. A second layer is then attached, providing the functional group (C18). Using this approach to shield the silica surface, a highly durable stationary phase is created. These columns are designed to be used in a pH range of 1 – 12 and have shown no loss of efficiency after 50 hours in a pH of 12 at 60 °C. Brownlee Spheri-5 ® This is small-pore silica-based sorbent for separating small molecules. Both monofunctional (comb-pre) and polyfunctional (polymerized loop-type) C8 and C18 sorbents available. 12 Description Brownlee HRes Biphenyl Brownlee HRes Biphenyl Brownlee HRes Biphenyl Brownlee HRes PFP Propyl Brownlee HRes PFP Propyl Brownlee HRes PFP Propyl Brownlee HRes Aqueous C18 Brownlee HRes Aqueous C18 Brownlee HRes Aqueous C18 Brownlee HRes IBD Brownlee HRes IBD Brownlee HRes IBD Brownlee HRes Analytical C18 Brownlee HRes Analytical C18 Brownlee HRes Analytical C18 Brownlee HRes Analytical DB Silica Brownlee HRes Analytical DB Silica Brownlee HRes Analytical DB Silica Brownlee HRes Analytical DB Cyano Brownlee HRes Analytical DB Cyano Brownlee HRes Analytical DB Cyano Brownlee HRes Analytical DB PAH Brownlee HRes Analytical DB PAH Length i.d. Particle Size Part No. 30 mm 50 mm 100 mm 30 mm 50 mm 100 mm 30 mm 50 mm 100 mm 30 mm 50 mm 100 mm 30 mm 50 mm 100 mm 30 mm 50 mm 100 mm 30 mm 50 mm 100 mm 50 mm 100 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 2.1 mm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 μm 1.9 um 1.9 um 1.9 um 1.9 um 1.9 um 1.9 um 1.9 um 1.9 um N9303911 N9303912 N9303913 N9303914 N9303915 N9303916 N9303917 N9303918 N9303919 N9303920 N9303921 N9303922 N9303852 N9303853 N9303854 N9303970 N9303971 N9303972 N9303973 N9303974 N9303975 N9303995 N9303996 Consult your area sales representative for quanity discounts See page 2 for ordering information and a complete listing of PerkinElmer offices. PerkinElmer Brownlee Columns Choose only genuine PerkinElmer BrownleeTM columns for the best separation results. Six different column types to meet all your analytical needs. Features and Benefits ■ Each column individually tested and certificate provided ■ End fittings compatible with a variety of HPLC systems ■ Do not require MPLC holders Conventional columns do not require MPLC holders. Conventional Columns Column Functionality Analytical Analytical Analytical Analytical Analytical Analytical Analytical Aquapore® Aquapore Aquapore Bio Bio CHOICE™ Amino C18 & C8 Cyano Biphenyl Phenyl Silica PAH AX-300 Octyl C8 ODS C18 C18 C8 Basix Pore Diameter Å % Carbon End Cap 110 110 110 110 110 110 110 300 300 300 300 300 60 2 13 4 – 6 – – – – – 6 – 12 No Yes Yes Yes Yes – Yes – – – Yes – Yes CHOICE CHOICE CHOICE CHOICE C18 Biphenyl Organic acids PFP propyl 60 60 60 60 27 23 – 17 Yes Yes No Yes Spheri-5® C8, C18, C18 ODS and Silica 80 – Validated™ Validated Validated Validated Validated Amino C1 C4 Aqueous C18 C18 100 100 100 100 100 2 5 9 15 20 No – Yes No Yes Validated Validated Validated Validated Validated Validated C8 Carbamate Cyano IBD PFP Phenyl 100 100 100 100 100 100 12 – 8 12 7 10 Yes – Yes No Yes Yes Validated Quat 100 – – – Applications Excellent for carbohydrate analysis Superior for non-basic analytes General purpose for normal or reversed-phase U.S. EPA Method 8330 General purpose for neutral analytes Ideal for polar analytes Maximum resolution of polynuclear aromatic hydrocarbons Used for ion exchange chromatography Used for reversed-phase chromatography Silica based support used for the separation of large biopolymers High molecular weight compounds and proteins High molecular weight compounds and proteins Ideal for LC/MS. Excellent for amine-containing compounds and basic pharmaceuticals Excellent for explosives or steroids Highly retentive and selective phase for aromatic compounds Used for challenging organic acids Ideal for MS, ELSD, or NPD detection of nucleosides, nucleotides, purines, pyrimidines or halogenated compounds Excellent for separating small molecules both non-functional and polyfunctional Ideal for carbohydrates Least retentive reversed-phase hydrocarbon packing High bonding coverage and base deactivation Excellent for highly water-soluble or poorly organic-soluble compounds Used for the detection of anilines, barbiturates, carbonyls, fat-soluble vitamins, fatty acids, glycerides, phthalates Less hydrophobic retention than C18 Fast analysis of carbamates Basic pharmaceuticals and steroids Unique separation for acids, bases, zwitterions and other polar compounds Ideal for taxors and precursors or halogenated compounds Separation of fatty acids, polynuclear aromatic hydrocarbons, purines and pyrimidines High purity, base deactivated reversed-phase packing Order online at www.perkinelmer.com/supplies ORDER TODAY 13 Conventional Columns for all HPLC Extensive column selection meets all your analytical needs Brownlee Analytical/Specialty Columns pH Range: 2.5 to 7.5 Length i.d. Particle Temp. Size Limit Pore Size Carb. Load End Cap Length Part No. Brownlee Analytical Amino Ideal for mono and disaccharide analyses. Most popular amino-based stationary phase. Routine analysis of simple sugars, using isocratic elution and a refractive index detector or an evaporative light scattering detector. 100 mm 150 mm 4.6 mm 4.6 mm 5 μm 5 μm 80 °C 80 °C 110 Å 110 Å 2% 2% No No N9303503 N9303504 Brownlee Analytical C8 Shorter retention times for hydrophobic compounds. Reliable performance with symmetrical peak shapes for neutral to acidic compounds. 100 mm 150 mm 4.6 mm 4.6 mm 5 μm 5 μm 80 °C 80 °C 110 Å 110 Å 7% 7% Yes Yes Brownlee Bio i.d. Particle Temp. Size Limit 150 mm 150 mm 2.1 mm 4.6 mm 5 μm 5 μm 110 Å 110 Å 110 Å 13% 13% 13% Yes Yes Yes N9303507 N9303512 N9303513 150 mm 150 mm 5 μm 80 °C 110 Å 4% Yes N9303522 Specifically designed for challenging analyses of polynuclear aromatic hydrocarbons. 3.2 mm 2.1 mm 5 μm 5 μm 80 °C 80 °C 110 Å 110 Å Yes Yes N9303430 N9303530 Unique selectivity especially for aromatic compounds. 4.6 mm 5 μm 80 °C N9303658 N9303659 2.1 mm 4.6 mm 5 μm 5 μm 300 Å 300 Å 5% 6% Yes Yes i.d. pH Range: 2.5 to 7.5 Particle Temp. Pore Size Limit Size Carb. Load End Cap Part No. 4.6 mm 5 μm 80 °C 60 Å 12% Yes N9303618 27% 27% 27% 12% Yes Yes Yes Yes N9303620 N9303621 N9303627 N9303628 Brownlee CHOICE C18 Excellent choice for LC/MS. Highly retentive phase for hydrophobic and slightly polar analytes. 2.1 mm 4.6 mm 2.1 mm 4.6 mm 3 μm 3 μm 5 μm 5 μm 80 °C 80 °C 80 °C 80 °C 60 Å 60 Å 60 Å 60 Å Brownlee CHOICE Organic Acids 110 Å 6% Yes N9303524 150 mm 250 mm 4.6 mm 2.1 mm 5 μm 5 μm 80 °C 80 °C 60 Å 60 Å N9303631 N9303632 Brownlee Analytical Silica Brownlee CHOICE Propyl Good general purpose packing for normal phase separations. Highly retentive for basic analytes. Excellent separation of nucleosides, nucleotides, purines, pyrimidines, halogenated compounds, beta blockers and tricyclic antidepressants. 150 mm 4.6 mm 5 μm 80 °C 110 Å Yes N9303525 150 mm 4.6 mm 5 μm 80 °C 60 Å 17% Yes For a full listing of Brownlee conventional columns, please visit: www.perkinelmer.com/lcsupplies 14 N9303648 N9303649 Enhanced retention and selectivity for polar organic acids. Retention is stable and reproducible even with 100% aqueous mobile phase specified in the AOAC method. Brownlee Analytical Phenyl 150 mm Yes Yes Excellent choice for analytes containing amine group functionality. 100 mm 100 mm 150 mm 150 mm Brownlee Analytical PAH 150 mm 250 mm 6% 6% Brownlee CHOICE Basix 150 mm Suitable for analyses of a wide range of compounds from acidic through slightly basic. Highly-base-deactivated spherical silica. 4.6 mm 300 Å 300 Å N9303515 N9303517 Brownlee Analytical Cyano 150 mm Part No. Excellent for separating peptides or proteins. Wide-pore HPLC column. Length 80 °C 80 °C 80 °C End Cap Brownlee Bio C18 Brownlee Choice 3 μm 5 μm 5 μm Carb. Load Wide-bore HPLC column. High proportion of pore/surface area available for large molecule separations. Suitable for a wide range of acidic to neutral hydrophobic compounds. Excellent all purpose column. 4.6 mm 4.6 mm 4.6 mm Pore Size Brownlee Bio C8 Brownlee Analytical C18 100 mm 100 mm 150 mm pH Range: 2.5 to 7.5 See page 2 for ordering information and a complete listing of PerkinElmer offices. N9303644 Instruments Brownlee Spheri-5® Brownlee Validated Length i.d. pH Range: 2.5 to 7.5 Particle Temp. Pore Size Limit Size Carb. Load End Cap Length Part No. Brownlee Validated Amino Good for normal phase analytes of mono-and disaccharides or similar compounds. 150 mm 4.6 mm 5 μm 80 °C 100 Å 2% N9303534 i.d. Particle Temp. Pore Size Limit Size 250 mm 4.6 mm 5 μm 150 mm Brownlee Spheri-10 C18 100 Å 15% N9303546 Least retentive reversed phase hydrocarbon packing. 4.6 mm 5 μm 80 °C 07120012 100 Å 4.6 mm 5 μm 07120016 Small pore silica-based sorbent for separating small molecules both non-functional and polyfunctional. Brownlee Validated C1 150 mm 5% N9303718 250 mm 4.6 mm 10 μm 07120001 Brownlee Validated C4 Brownlee pH-ex C18 High bonding coverage and base deactivation. Less retention that C18 or C8 phases. 150 mm 4.6 mm 5 μm 80 °C 100 Å 9% Yes N9303720 Retentive, high purity-base deactivated reversed phase packing. 2.1 mm 4.6 mm 5 μm 5 μm 80 °C 80 °C 80 Å 80 Å 12% 12% Yes Yes N9303566 N9303567 Brownlee Validated C18 pH Range: 1.0 to 12.0 Especially useful for applications requiring high/low pH ranges (1–12). A silica based C18 column with exceptional stability. Brownlee Validated C8 150 mm 150 mm Part No. Small pore silica-based sorbent for separating small molecules both non-functional and polyfunctional. 250 mm 80 °C End Cap Brownlee Spheri-5 C8 Highly base deactivated. Compatible with highly aqueous mobile phases. 5 μm Carb. Load Brownlee Spheri-5 C18 Brownlee Validated Aqueous C18 4.6 mm pH Range: 2.5 to 7.5 Length i.d. Particle Temp. Pore Size Limit Size 30 mm 50 mm 100 mm 150 mm 4.6 mm 4.6 mm 4.6 mm 4.6 mm 3 μm 3 μm 3 μm 3 μm 80 °C 80 °C 80 °C 80 °C Carb. Load End Cap 140 Å 140 Å 140 Å 140 Å Part No. N9303855 N9303856 N9303857 N9303858 Excellent general purpose phase column. Retentive high purity packing. 150 mm 150 mm 2.1 mm 4.6 mm 5 μm 5 μm 80 °C 80 °C 100 Å 100 Å 20% 20% Yes Yes N9303556 N9303558 Brownlee Validated Carbamate A unique stationary phase specifically designed for carbamate analysis. This column is compatible with fluorescence or LC/MS detection, and is designed for fast analysis times, reducing solvent usage. 100 mm 4.6 mm 3 μm 80 °C 100 Å N9303569 Brownlee Validated Cyano High purity Cyano phase with few silanol sites. Less sensitive to small amounts of water present in the mobile phase. 150 mm 4.6 mm 5 μm 80 °C 100 Å 10% Yes N9303575 3 μm 5 μm 80 °C 80 °C 100 Å 100 Å i.d. Particle Temp. Pore Size Limit Size Carb. Load End Cap Part No. Method Validation Column Kit Includes set of three identical Brownlee Validated C18 columns from different lots. Ideal to check robustness in the method validation process. Packing materials of varying lot #’s. 4.6 mm 5 μm N9303950 C18 Lot Specific Column Kit Includes 3 Brownlee Validated C18 columns. Ideal tool for the R & D and Contract Lab applications working on specific projects and studies. Identical lot# specific packing material guaranteed. Absolute minimal variability and one convenient kit for long-term use. Unique selectivity and a high level of base-deactivation. Reduces or eliminates the need for mobile phase additives. 4.6 mm 4.6 mm Length 150 mm Brownlee Validated IBD 150 mm 150 mm Conventional Column Kits 12% 12% N9303593 N9303582 150 mm 4.6 mm 5 μm N9303951 Brownlee Validated PFP Unique selectivity for compounds containing organohalogens or other basic functional groups. 150 mm 4.6 mm 5 μm 80 °C 100 Å 7% Yes N9303599 Brownlee Validated Phenyl High purity, highly retentive base-deactivated phase, especially designed for aromatic analytes. 150 mm 4.6 mm 5 μm 80 °C 100 Å 10% Yes N9303606 Purchase 2 or more on Brownlee Cartridge Columns and Save!!!! Consult your authorized PERKINELMER Sales Representative for Volume Discounts and Promotions Order online at www.perkinelmer.com/supplies ORDER TODAY 15 Brownlee Cartridge Columns for Quality Brownlee Sorbents PerkinElmer Brownlee™ cartridge columns are offered in a wide range of sorbent material. Choose the right sorbent for the analysis and mode of separation being used. Aquapore® – is a wide-pore, silica-based support suitable for the separation of large biopolymers. Spheri-5® – is a small-pore, silica-based solvent for separating small molecules. Both monofunctional (comb-type) and polyfunctional (polymerized loop-type) C8 and C18 sorbents are available. Polypore® – is a polymer-based (microporous, 10 μm) sorbent for the analysis of organic acids and sugars. Validated™ – is a small-pore, silica-based C18 sorbent for small molecules, specifically for consistent pharmaceutical assays. Pecosphere™ – is a small-pore, silica-based sorbent for HPLC of small molecules. Reduced Activity – is a small-pore, base deactivated silica-based, reversed-phase sorbent (C18 or C8) developed for HPLC of basic analytes and pharmaceuticals. CHOICE™ – is a small-pore, base deactivated silica-based, reversed-phase sorbent (C18) developed for LC/MS separations. Peco HCODS – is especially suited for reversed-phase separation of proteins and peptides. Brownlee Cartridge Columns 16 Column Functionality Pore Diameter Å % Carbon End Cap Aquapore Aquapore Aquapore Aquapore Choice Choice Choice Pecosphere Pecosphere CR Pecosphere CR Peco HCODS Polypore Polypore Reduced Activity AX-300 (anion exchange) OD-300 (C18) RP-300 (C8) BU-300 (C4) C18 C8 PFPP (Pentafluorophenylpropyl) C18, monofunctional C18 C8 C18, polyfunctional CA (calcium form), Mixed Mode H (hydrogen form), Mixed Mode C18 300 300 300 300 100 100 100 80 80 80 300 Microporous Microporous 80 10 5 3 12 7 5 11 11 11 9 12 Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Reduced Activity Spheri-5 Spheri-5 Spheri-5 Spheri-5 C8 RP-18 (monofunctional C18) ODS (polyfunctional C18) RP-8 (monofunctional C8) Phenyl (C5) 80 80 80 80 80 5 11 14 6 6 Yes Yes Yes Yes Yes Spheri-5 Spheri-5 Spheri-5 Validated Amino Cyano Silica C18 80 80 80 100 3 4 18 No No Yes VeloSep VeloSep RP-18 (C18) RP-8 (C8) 100 100 14 7 Yes Yes Applications Silica-based support for larger anionic compounds Silica-based support for larger compounds by reversed-phase Same as above, but for slightly more polar compounds Same as above, but for even somewhat more polar compounds For high speed/efficiency separation of basic compounds/pharmaceuticals For high speed/efficiency separation of basic compounds/pharmaceuticals For high speed/efficiency separation of basic drugs, especially for LC/MS Reversed-phase column for fast separation of smaller compounds Same as above, but for more basic compounds Same as above, but, also, for slightly more polar compounds Especially suited for reversed-phase separation of proteins and peptides Especially suited for separation of organic acids, as well as sugars Especially suited for separation of sugars, as well as organic acids Reversed-phase sorbent geared for fast separation of basic compounds/pharmaceuticals Same as above, but for slightly more polar compounds Reversed-phase separation of smaller compounds Same as above, but with somewhat different selectivity Reversed-phase separation of more basic smaller compounds Especially suited for hydrophobic interaction separation of biomolecules, where the activity of the compound must be preserved Normal-phase separation of smaller, relatively more polar compounds Same as above, but with somewhat different selectivity Same as above, but with different selectivity Reversed-phase separations in which very little variation in both lot-to-lot and column-to-column variability can be tolerated Reversed-phase column for high through-put and minimal solvent usage Same as above, but for slightly more polar compounds See page 2 for ordering information and a complete listing of PerkinElmer offices. and Flexibility Brownlee ™ Analytical Cartridge Columns for conventional and narrowbore HPLC Analytical cartridges from the Brownlee line are available in three lengths (30, 100 and 220 mm) and two internal diameters (4.6 and 2.1 mm). The MPLC cartridge system allows direct coupling of a cartridge to a guard without any dead-volume. Changing cartridges is easy with the finger-tight cartridge design, which does not require any wrench tightening of the holder or disconnecting of tubing from the LC system. Peco MPLC holders (83 and 33 mm). Brownlee VeloSep ® Features and Benefits ■ Quality – manufactured under ISO-9001 certified quality control procedures ■ Quick and easy cartridge change with the finger-tight design ■ Flexible – same reusable holder for 2.1 and 4.6 mm cartridges ■ Economical – less expensive than conventional columns Brownlee CHOICE ™ The CHOICE™ columns provide the speed and efficiency appropriate for LC/MS. Each column’s separation requirements vary depending on the system, sample and mass spectrometer. Brownlee PECO PerkinElmer pioneered the development of Fast HPLC and introduced the popular 3 x 3 column. This column is capable of rapid analysis, as short as one to two minutes. The 83 mm long 3 x 8 column with > 10,000 plates can separate many complex mixtures in less than 10 minutes. Peco cartridges are available with MPLC® holders. Three cartridge lengths (33, 83 and 150 mm) are available in 4.6 mm i.d. Brownlee Preparative Preparative columns are 10 mm i.d. cartridges, packed with Aquapore® 20 μm, 300 Å sorbents. Save time with high-pressure preparative runs up to 3000 psi and achieve high performance with the 20 μm, 300 Å sorbents. Typical sample capacity of the 250 mm cartridge is 50 mg to 1 g of material; the typical flow rate is 4 – 10 mL/min. For a full listing of Brownlee cartridge columns, please visit: www.perkinelmer.com/lcsupplies VeloSep columns are 3.2 mm i.d. cartridges packed with 3 μm reversed-phase support for high throughput analysis and reduced solvent consumption. VeloSep is packed with 3 μm C8 or C18 sorbents and available in 40 or 100 mm lengths. Brownlee Validated Brownlee Validated sorbent is derived from a neutral “Type B” silica with inherent low silanophobic activity. Each sorbent is tested to meet stringent specifications for the separation of basic, neutral and acidic test probes. A high-temperature bonding technique is coupled with an exhaustive end-capping procedure to ensure maximum coverage of the silica surface. A proprietary treatment step is used to further eliminate any trace residual metals in the silica that create active absorptive sites. This is a highly deactivated column which yields excellent peak shape for difficult base analytes, pharmaceuticals and small peptides. NewGuard Columns NewGuard cartridges are small guard cartridges (15 mm x 3.2 mm i.d.) packed with 5 or 7 μm sorbents. NewGuard columns prolong column life 2 to 5 times by eliminating particulates, contaminants and strongly bound sample components. They act as disposable, replaceable heads of your analytical columns. NewGuard columns are easily coupled to MPLC cartridges or conventional columns. Brownlee MPLC/Peco Holders MPLC cartridge system ensures leak-free operation up to 7000 psi, with only finger-tightening. The high-pressure seal in each end assembly actually seals tighter as pressure increases. No wrenches are required and there is no need to disconnect any tubing to your LC system when changing a cartridge. MPLC cartridges can be directly coupled to another using a union. Purchase 2 or more Brownlee Cartridge Columns and Save!!! Consult your authorized PERKINELMER Sales Representative for Volume Discounts and Promotions. Delivering enhanced VALUE and outstanding SAVINGS on the products you use most! Order online at www.perkinelmer.com/supplies ORDER TODAY 17 Brownlee MPLC Cartridge Columns for Brownlee cartridge columns offer an extensive range of phases and column lengths Ion Exchange Column AX-300, Aquapore® Description 30 mm x 4.6 mm i.d.* 2 per package Part No. 30 mm x 2.1 mm i.d.* 2 per package Part No. 100 mm x 4.6 mm i.d.** 1 per package Part No. 7 μm, 300 Å, weak anion 07110073 07110074 07110075 Polypore CA 10 μm, polymeric, calcium form 07110091 07110093 Polypore H 10 μm, polymeric, hydrogen form 07110085 07110087 Description 30 mm x 4.6 mm i.d.* 2 per package Part No. Aminopropyl, 5 μm, 80 Å 07110037 07110039 Cyanopropyl, 5 μm, 80 Å 07110043 07110045 ® Polar Phase Column Amino, Spheri-5 ® Cyano, Spheri-5 Silica, Spheri-5 5 μm, 80 Å 07110031 Silica, Spheri-10 10 μm, 80 Å 07110145 30 mm x 2.1 mm i.d.* 2 per package Part No. 100 mm x 4.6 mm i.d.** 1 per package Part No. 07110032 07110033 Description 30 mm x 4.6 mm i.d.* 2 per package Part No. 30 mm x 2.1 mm i.d.* 2 per package Part No. 100 mm x 4.6 mm i.d.** 1 per package Part No. BU-300, Aquapore Butyl C-4 7 μm, 300 Å 07110061 07110062 Cyano, Spheri-5 Cyanopropyl, 5 μm, 80 Å 07110043 OD-300, Aquapore ODS C-18, 7 μm, 300 Å 07110235 07110234 07110232 ODS, Spheri-5 C-18, polyfunctional, 5 μm, 80 Å 07110019 07110020 07110021 Phenyl, Spheri-5 Phenyl, 5 μm, 80 Å 07110025 RP-8, Spheri-5 C-8, monofunctional, 5 μm, 80 Å 07110001 RP-18, Spheri-5 C-18, monofunctional, 5 μm, 80 Å 07110013 07110014 07110015 RP-300, Aquapore Octyl C-8 7 μm, 300 Å 07110055 07110056 07110057 Pecosphere C18 C-18, monofunctional, non-reduced, 3μm, 80A 02580164 Pecosphere 3CR *** C-8, Base Deactivated, 3 μm 02580191 Pecosphere 3CR *** C-18, Base Deactivated, 3 μm 02580195 Reversed Phase Column 07110045 07110027 07110002 07110003 0258-0220 Pecosphere C18 100 x 3.2 mm monofunctional, non-reduced, 3 um, 80A column 0258-0221 * Requires Holder (07150013) 18 ** Requires Holder (07150014) *** Pack of 5 See page 2 for ordering information and a complete listing of PerkinElmer offices. Choice and Variety Scavenger Columns Column Description 33 mm x 4.6 mm i.d.* 5 per package Part No. Silica Scavenger 10 μm 02580203 C18 Scavenger Monofunctional, 10 μm, 80A 02580202 Ion Exchange Column 100 mm x 2.1 mm i.d.** 1 per package Part No. Description 220 mm x 4.6 mm i.d.*** 1 per package Part No. AX-300, Aquapore 7 μm, 300 Å, weak anion 07110077 Polypore® CA 10 μm, polymeric, calcium form 07110095 Polypore H 10 μm, polymeric, hydrogen form 07110089 220 mm x 2.1 mm i.d.*** 1 per package Part No. Polar Phase 100 mm x 2.1 mm i.d.** 1 per package Part No. 220 mm x 4.6 mm i.d.*** 1 per package Part No. Column Description Amino, Spheri-5 Aminopropyl, 5 μm, 80 Å 07110041 Cyano, Spheri-5 Cyanopropyl, 5 μm, 80 Å 07110047 Silica, Spheri-5 5 μm, 80 Å 07110035 220 mm x 2.1 mm i.d.*** 1 per package Part No. Reversed Phase Column Description 100 mm x 2.1 mm i.d.** 1 per package Part No. BU-300, Aquapore Butyl C-4 7 μm, 300 Å 07110064 Cyano, Spheri-5 Cyanopropyl, 5 μm, 80 Å OD-300, Aquapore ODS C-18, 7 μm, 300 Å 07110233 07110231 07110236 ODS, Spheri-5 C-18, polyfunctional, 5 μm, 80 Å 07110022 07110023 07110024 Phenyl, Spheri-5 Phenyl, 5 μm, 80 Å RP-8, Spheri-5 C-8, monofunctional, 5 μm, 80 Å C-18, Base Deactivated, 3 μm RP-18, Spheri-5 C-18, monofunctional, 5 μm, 80 Å 07110047 07110004 07110005 07110006 07110016 07110017 07110018 07110059 07110060 Pecosphere 3CR C-8, Base Deactivated, 3 μm RP-300, Aquapore Octyl C-8 7 μm, 300 Å 07110058 Pecosphere C18 C-18, monofunctional, nonreduced, 3 μm, 80 Å 0258-0220 ** Requires Holder (07150014) 220 mm x 2.1 mm i.d.*** 1 per package Part No. 07110029 Pecosphere 3CR * Requires Holder (07150028) 220 mm x 4.6 mm i.d.*** 1 per package Part No. *** Requires Holder (07150015) Order online at www.perkinelmer.com/supplies ORDER TODAY 19 Brownlee NewGuard Cartridge Columns Guard Cartridge Columns and Accessories NewGuard Columns NewGuard cartridges are small guard cartridges (15 mm x 3.2 mm i.d.) packed with 5 or 7 μm sorbents. NewGuard cartridges prolong column life by eliminating particulates, contaminant's, and strongly bound sample components. They act as replaceable, disposable heads of your analytical columns. There is negligible loss of efficiency and little effect on retention or resolution. NewGuards are available in a convenient 3-pack and can be coupled directly to any MPLC cartridge with a union (07150018). NewGuard cartridges directly coupled to a 220 mm MPLC cartridge and connected externally to a 250 mm conventional column. Features and Benefits ■ Prolong column life by 2 to 5 times ■ Protect your column from particulates and strongly bound sample components ■ Optimized dimensions to prevent loss of resolution ■ Easy coupling to MPLC cartridges or conventional columns ■ Finger-tight seal to 7000 psi using NewGuard holders ■ Can be used for sample preconcentration (connected to sample injection loop) View of the NewGuard holder and a NewGuard 3/pack. 15 mm cartridge*, 3.2 mm i.d., 3 per pkg. Standards Solutions Description Part No. Test Mix Amino, Aquapore® Amino, 7 μm spherical Anion, Aquapore Anion, 7 μm spherical Cyano, Aquapore Cyano, 7 μm spherical Diol, Aquapore Diol, 7 μm spherical Phenyl, Aquapore Phenyl, 7 μm spherical RP-2, Aquapore Dimethyl, 7 μm spherical RP-4, Aquapore Butyl, 7 μm spherical RP-8, Aquapore Octyl, 7 μm spherical RP-18, Aquapore ODS, 7 μm spherical Silica, Aquapore Silica, 7 μm spherical Validated®, C18, 5 μm spherical 07110098 07110102 07110100 07110105 07110096 07110086 07110088 07110090 07110092 07110106 00402237 Description Part No. LC Gradient Test Mix Universal test mix for reversed-phase (5 mL/pkg.) N9334010 00890893 Standards Description Part No. HPLC SV Calibration Mix #5/610 PAH HPLC 610 Calibration Mix A HPLC 610 Calibration Mix B 00891542 00891543 00891544 * Requires holder (07150001) Note: Actual bed length of NewGuard is about 13 mm Replacement Seals for MPLC and Prep-10 Holders 20 Item Description Part No. Prep-10 Inlet Seal Prep-10 Outlet Seal Seals for MPLC Holders Seal Replacement Kit for MPLC Holders One each (Prep-10 Seal Replacement Kit tools required) One each (Prep-10 Seal Replacement Kit tools required) Two 7000 psi seals (Seal Replacement Kit tools required) Tools and two 7000 psi seals 07150012 07150026 07150024 07150023 See page 2 for ordering information and a complete listing of PerkinElmer offices. and Holders for choice and variety MPLC/Peco™ Holders The patented MPLC cartridge system ensures leak-free operation up to 7000 psi, with only finger-tightening. The high-pressure seal in each end assembly actually seals tighter as pressure increases. No wrenches are required, and there is no need to disconnect any tubing to your LC system when changing a cartridge. Each MPLC cartridge can be directly coupled to another using a union. Name Description Part No. Universal Holder Kit 07150025 33 mm Pecosphere Holder Includes 100 and 220 mm holder bodies, 2 end assemblies, 1 union, 1 NewGuard end assembly. Holds a single NewGuard cartridge or a single 20 mm CHOICE™ cartridge. Holds a single MPLC and CHOICE 30 mm cartridge. (Do Not use with Pecosphere column) Holds 33 mm Fast LC Peco cartridge only. 50 mm Holder 83 mm Peco Holder Holds a single 50 mm CHOICE cartridge only. Holds 83 mm Fast LC Peco cartridge only. N2580030 07150029 100 mm Holder Holds a single MPLC 100 mm cartridge. 07150014 150 mm Holder Holds a single MPLC 150 mm cartridge. 07150030 220 mm Holder Holds a single MPLC 220 mm cartridge. 07150015 250 mm Holder 100 mm NewGuard System Holder 220 mm NewGuard System Holder 130 mm MPLC System Holder Union Holds a single MPLC 250 mm cartridge. Holder for a NewGuard and a 100 mm coupled cartridge. 07150031 07150016 Holder for a NewGuard and a 220 mm coupled cartridge. Holder for a 30 and 100 mm coupled cartridge. 07150017 For direct coupling of 2 cartridge holders. (Two holder bodies and 2 end assemblies also required.) Upgrades a 30 mm holder to a NewGuard holder. 07150018 07150002 Holder component. 07150019 30 mm Holder Body Holder component. 07150020 100 mm Holder Body Holder component. 07150021 220 mm Holder Body Holder component. 07150022 NewGuard® Holder 30 mm Holder NewGuard End Assembly End Assembly 07150001 07150013 07150028 07150032 Prep-10 Cartridge Holders Name Description Part No. 100 mm Prep-10 Holder Holds a single 100 mm Prep-10 cartridge. 07150005 250 mm Prep-10 Holder Holds a single 250 mm Prep-10 cartridge. 07150006 Order online at www.perkinelmer.com/supplies ORDER TODAY 21 sample loops Stainless Steel Sample Loops for Flexar FX UHPLC Autosampler (up to 18,000 psi operation) SS loops required for use with FX-10 or FX-15 systems operating above 6,200 psi. Compatible with Series 275 autosampler. Interferene High Pressure Check Sample Standards Loops Description Part No. 2 μL Sample Loop, SS 5 μL Sample Loop, SS 10 μL Sample Loop, SS 20 μL Sample Loop, SS 50 μL Sample Loop, SS 100 μL Sample Loop, SS 200 μL Sample Loop, SS 500 μL Sample Loop, SS 1 mL Sample Loop, SS 2 mL Sample Loop, SS 5 mL Sample Loop, SS N2936071 N2936056 N2936057 N2936058 N2936059 N2936060 N2936061 N2936062 N2936063 N2936064 N2936065 Size 10 μL 50 μL 100 μL 200 μL 5 mL Model 7125/7010 Part No. Model 7725 Part No. 09904938 09904940 09904942 09904818 N9306024 N9306026 N9306027 N9306028 Model 8125 Part No. 41000013 09904818 N9306032 PEEK Sample Loops for Series 200/225 and Flexar LC Autosamplers (up to 6,200 psi operation) Note: these loops are compatible with all standard Flexar autosamplers as well as Series 225 autosamplers. Note: PEEK loops cannot be used above 6,200 psi operation therefore are NOT compatible eith standard Flexar autosamplers. Stainless steel loops required for use wirh FX-10 or FX-15 UHPLCsystems operating above 6,200 psi. Description Size PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop 2 μL 5 μL 10 μL 20 μL 50 μL 100 μL 250 μL 500 μL 1 mL 2 mL 5 mL Part No. N2936072 N2936073 N2936074 N2936075 N2936076 N2936077 N2936078 N2936079 N2936080 N2936081 N2936082 PEEK Sample Loops Sample loops are made from PEEK tubing and fittings. PEEK (poly-ether-ether-ketone) is a mechanically-strong, chemically-inert polymer, ideal for HPLC applications where metal surfaces may interact with the mobile phase or sample component. Each sample loop is supplied with two PEEK hex-head nuts and ferrules. These fittings grip the tubing in two locations for a more reliable connection. Description Size PEEK Sample Loop PEEK Sample Loop PEEK Sample Loop Internal Loop (PEEK and Ceramic) 20 μL 50 μL 200 μL 2 μL Clean-Cut Tubing Cutter Clean-Cut™ tubing tool is designed to cut Teflon®, Tefzel® and polymers in general but, in particular, PEEK tubing. The compact design enables every chromatographer to carry it in his pocket. A unique safety locking mechanism secures the blade when not in use. Stainless Steel Sample Loops 22 Sample Loops and Tubing Part No. N9306035 N9306036 N9306038 N9306022 Tubing Accessories Description Part No. Clean-Cut Tubing Cutter Clean-Cut Tubing Replacement Blade Cable/Tubing clip (U-Shaped) ED020015 ED020016 NX598006 PEEK Tubing PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of PEEK tubing eliminates the permeability to organic solvents that causes Tubing and Connectors other polymer tubing, such as Tefzel ®, to sweat. Use PEEK with virtually any organic or inorganic liquid. PEEK tubing is not affected by halide salts, high-strength buffers or other aggressive mobile phases that degrade stainless steel. PEEK Tubing Description Length Part No. ⁄16 in o.d. x 0.007 in i.d. 1 ⁄16 in o.d. x 0.010 in i.d. 1 ⁄16 in o.d. x 0.005 in i.d. (black) 1 ⁄16 in o.d. x 0.004 in i.d. (red) Connector tubing, Flexar/FX mixer to injector, SS Connector tubing, Flexar iso/binary/ quaternary pump to autosampler, SS 5 ft 5 ft 50 cm 50 cm N9302678 N9302650 N2916200 N2916059 N2916211 1 N2916210 Stainless Steel Tubing ■ Pre-cut and mirror-polished in 316 stainless steel Description Length Part No. ⁄16 in o.d. x 0.015 in i.d. 1 ⁄16 in o.d. x 0.007 in i.d. 6 ft 3 ft 00873036 02540838 1 See page 2 for ordering information and a complete listing of PerkinElmer offices. fingertight fittings One-piece, easy-to-use Fingertight® fittings PEEK Fingertight ® Fittings High-performance Fingertight® fittings for the most demanding applications. This PEEK Fingertight® fitting is the toughest with regard to chemical resistance and pressure. This high-performance Fingertight® fitting is recommended for the most demanding applications and will resist pressures up to 6,000 psi (400 bar). Made from a single piece of PEEK, the size permits tightening without tools. Description Part No. PEEK One-Piece Fingertight Fitting ® ED020005 Fittings Kits Fittings: Nuts, Ferrules and Connectors Stainless steel nuts are available in both Parker-Hannifin and Rheodyne™ formats. The nuts are used to connect 1⁄16 inch o.d. stainless steel tubing and feature a 10-32 thread size. PerkinElmer also offers select SSI fittings for 1⁄16 inch o.d. tubing in 1⁄4 -28 thread size. Biocompatible Column Fittings for LC. Recommended for users of a PerkinElmer Biocompatible LC system. Contains nuts, ferrules and unions. Part No. N9301001 Stainless Steel Fittings Description Part No. Kel-F Reverse Ferrule, 1⁄8 inch* Kel-F Ferrule , 1⁄16 inch* Parker-Hannifin Ferrule, 1⁄16 inch Parker-Hannifin Nut, 1⁄16 inch Parker-Hannifin Nut & Ferrule Kit, 1⁄16 inch Includes: 6 nuts and 6 ferrules Parker-Hannifin Zero-Dead-Volume Union with nuts and ferrules Parker-Hannifin Medium-Stem SS Nut Rheodyne™ Ferrule, 1⁄16 inch Rheodyne™ Nut, 1⁄16 inch long body Rheodyne™ Nut, 1⁄16 inch short body Rheodyne™ Nut and Ferrule Kit, 1⁄16 inch Includes: 6 ferrules, 3 short nuts and 3 long nuts Tefzel Nut (for Reverse Ferrule), 1⁄8 inch* Tefzel Fut, 1⁄16 inch* Valco Ferrule 09903771 09920382 00873032 09903980 00890945 Fittings Kit for LC All-in-one fittings kit. The kit contains Rheodyne™ and SSI nuts and ferrules as well as Fingertight ® II nuts and ferrules for toolless installation. Zero-dead-volume unions are also included. In addition you receive varying lengths of stainless steel tubing in 0.007 and 0.010 inch i.d.s, as well as 0.30 inch i.d Tefzel® tubing. Part No. 09903289 N9301002 N2916202 09904947 09904974 09904956 02540274 N2601189 09920381 09903891 Operation Kit Recommended for purchasers of their first LC. Includes tubing, union, fittings, syringe, basic LC book and test mix. Part No. 00890873 *The Tefzel and Kel-F fittings above are only for low pressure use (under 400 psi). Order online at www.perkinelmer.com/supplies ORDER TODAY 23 Enhance the Performance of your HPLC Vacuum kits for all your degassing requirements Check Valves HPLC check valves allow solvent to flow in only the desired direction. Check valves are easy to install with the torque wrench kit. For all PerkinElmer pumps an intermediate check valve is required. The input check valve, which is identical, should be ordered. The check valves of the biocompatible pumps differ from those of the stainless steel pumps in that all portions that contact fluid are composed of titanium. Degassing Kits Using a solvent degassing system will extend the performance of your pump. PerkinElmer offers both vacuum degassing systems that can handle all your degassing requirements. Series 200 On-Line Vacuum Degasser Kit This is a low-volume, high efficiency, on-line module for the removal of dissolved gasses from HPLC solvents. The vacuum degasser is available in 3 and 5 channel models to support isocratic, binary and quaternary pumps as well as degassing of autosampler flush solvent. Description Part No. 3-channel Vacuum Degassing Package Includes: a Vacuum Degasser, one 1 L Bottle with Cap, one 2 L Bottle with Cap, one Organizer Tray and Accessory 5-channel Vacuum Degassing Package Includes: a Vacuum Degasser, two 1 L Bottle with Caps, two 2 L Bottles with Caps, Solvent Tray and Organizer Binary Bottle Cap Kit Includes: two Caps, Tubing, Fittings and Labels required for two Solvent Bottles Quatenary Bottle Cap Kit Includes: four Caps, Tubing, Fittings and Labels required for four Solvent Bottles Inlet/Intermediate Check valve Outlet Check valve Type Part No. Part No. Standard Stainless Steel Micropump Biocompatible Titanium 02540177 02540177 N2600226 02540197 02540197 N2600192 N2600571 N2600570 N2600522 N2600523 Liquid Chromatography Laboratory Bottle Kits 24 Check Valves Description Part No. 1x5 Liter Bottle with Cap and Teflon Insert, 2 Meters PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit 1x2 Liter Bottle with Cap and Teflon Insert 1 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit 1x1 Liter Bottle with Cap and Teflon Insert 1 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit 1x0.5 Liter Bottle with Cap and Teflon Insert 1 Meter PTFE 1⁄16" Tubing and 1x40 μm SS Solvent Frit 1 Cap with Teflon Insert 1 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit 1 Cap with Teflon Insert 1 Meter PTFE 1⁄16" Tubing and 1x40 μm SS Solvent Frit 1x0.5 Liter Bottle with Cap and Dual Teflon Insert 2 pcs of 2 Meter PTFE 1⁄8" Tubing (Piston Wash Function) 1 Cap with Dual Teflon Insert 2 pcs of 2 Meter PTFE 1⁄8" Tubing and 1x10 μm SS Solvent Frit (Piston Wash Function) N2601610 N2601611 N2601612 N2601613 N2601614 Maintenance Kits and Tools Description Part No. Biocompatible Piston Seal Replacement Kit Includes: Four Seals, Backup Rings, and O-rings Check Valve Torque Wrench Diaphragm for Pulse Compensator FX-15 UHPLC Pump Accessories Replacement 0.5 μm filter frits for FX-15 (4-pack) High pressure FX-15 piston seal kit Standard Piston Seal Replacement kit for series 200 and Flexar Pump Includes: Four Seals, Backup Rings, and O-rings Insertion Tool Micropump Piston Seal Replacement Kit for series 275 and FX10 pump Piston wash bottle kit for FX-15 Pulse Compensator Repair Kit Includes: Diaphragm, Elastomer Plug, and Seal Seal Removal Tool Series 200 Bio LC Pump Maintenance Kit Includes: Fuses, Seals, O-rings, and Seal Tools Series 200 Pump Maintenance Kit Includes: Fuses, Seals, O-rings, and Seal Tools N2910385 02540871 N2601316 N2911224 N2911221 N2910383 N2601503 N2910384 N2601616 N2600313 N2601295 N2910346 N2910345 N2601615 N2601616 N2601617 Replacement Vacuum Degasser Bottles Description Part No. 1 L Glass Bottle 2 L Glass Bottle N2600497 N2600498 See page 2 for ordering information and a complete listing of PerkinElmer offices. Pump Static Mixers Static mixers are used to facilitate complete mobile phase blending, resulting in improved retention performance. The mixer will most typically be used where high-pressure blending of two pump outputs is required. Mixers incorporate a highly efficient crossflow shearing mechanism which produces vortex sheer mixing over a wide flow range. UHPLC Static Mixers (up to 18000 psi) Description Solvent Sparger and Solvent Filters Solvent filters remove unwanted particulate matter from the LC instrument. Spargers connect directly to the solvent delivery line and are easily removed for cleaning. The scavenger column is ideal for eliminating particulate material from solvents. Solvent Spargers, Filters, and Scavengers Solvent Reservoir Sparger Description Size Stainless Steel Titanium Stainless Steel Titanium 10 μm 10 μm 40 μm 40 μm Size In-Line High Pressure Mixer Assembly, SS In-Line High Pressure Mixer Assembly, SS In-Line High Pressure Mixer Assembly, SS In-Line High Pressure Mixer Assembly, SS In-Line High Pressure Mixer Assembly, SS Binary T-Mixer, SS Binary high pressure T-Mixer, SS HP Binary high pressure T-Mixing, SS Binary high pressure T-Mixer, SS Binary high pressure T-Mixer, SS T-connector, SS 50 μL 150 μL 250 μL 350 μL 500 μL 10 μL 50 uL 150 μL 350 uL 500 uL Part No. N2911200 N2911201 N2911202 N2911205 N2911203 N2911170 N2911212 N2911206 N2911210 N2911211 N2911127 Part No. 09903610 N2600070 09903615 N2600089 Solvent Filters/Scavengers Description Part No. In-Line Solvent Filter System In-Line Solvent Filter Replacement Kit In-Line Solvent Filter System, Titanium Replacement 2 μm Titanium Filter Element Replacement Seal for In-Line Solvent Filter 3cm Scavenger Cartridge Holder Spheri-5 C18 10μm Scavenger Column (5 pack) 09903606 02540311 N2600259 N2601477 N2601262 02580178 02580202 LC System Accessories Description Part No. Solvent waste cup 90° Elbow adapter, 1⁄4" ID HDPP Tubing clip (U-shaped, polypropylene) N2916019 09220102 NX598006 Analytical Static Mixers (up to 6200 psi) ■ Improve gradient accuracy and increase sensitivity ■ Reduce baseline noise ■ In-line binary format Description Binary T Mixer Binary T Mixer In-Line Mixer Assembly In-Line Mixer Assembly Binary T Mixer Cartridge Binary T Mixer Cartridge Binary T Mixer Cartridge Binary T Mixer Cartridge Binary T Mixer Cartridge Size Part No. 10 μL 25 μL 150 μL 500 μL 10 μL 25 μL 50 μL 150 μL 250 μL N2911170 N2911171 N2911173 N2911172 N2911174 N2911175 N2911176 N2911177 N2911178 Series 200 Dynamic Mixer Series 200 Dynamic Mixer Accessory (100-240 V) – Used to facilitate complete mobile phase blending, resulting in improved retention performance. The mixer will most typically be used as part of a Series 200 Micro pump package – where high-pressure blending of 2 pump outputs is required. Three different volume mixing heads (75, 200 and 400 μL) are available. Kit includes: Mixer Accessory, Stainless Steel “Tee” Fitting (N2911127), U.S. style AC Line Cord and 0.1 A Type T Fuse. Part No. N2910520 Mixing Heads Mixing Head Size Part No. 75 μL 200 μL 400 μL N2910521 N2910522 N2910523 Order online at www.perkinelmer.com/supplies ORDER TODAY 25 supplies and accessories Injection valves and rotor seals for analytical HPLC Rheodyne ™ 9725 PEEK Bio Injection Valve Flom Analytical Injection Valve The Flom Analytical Injection Valve is a very reliable manual HPLC injection valve. It comes with a built in “Inject” contact closure connection output. A PEEK rotor seal is provided for excellent solvent/sample resistance and the fluid path is designed for minimal dispersion. This valve is available in either stainless steel or PEEK, depending on the application or need. Description Part No. Flom Injection Valve Stainless Steel Flom Injection Valve PEEK N9306073 N9306072 Injector Valve Rotor Seals For both Series 200 Autosampler and manual injectors. For both the Rheodyne and Flom valves, rotor seals should be periodically replaced every 6 months to a year and are available in PEEK. For the Rheodyne valve, they are also available in Vespel. PEEK is more inert towards amines and other basic biomolecules/pharmaceuticals, exhibiting less sample carryover. However, Vespel is somewhat more resilient than PEEK, providing somewhat better wear life. Description Part No. Flom Rotor Seal PEEK Rheodyne 7725 Vespel Rotor Seal Rheodyne 8125 Vespel Rotor Seal Rheodyne 7725/9725 PEEK Rotor Seal N9306068 09904802 10070900 N9306044 For a full listing of Rheodyne ™ injection valves, please visit: www.perkinelmer.com/lcsupplies 26 Model 9725 is inert and well-suited to the chromatography of biological molecules, including applications with aggressive mobile phases. This valve is useful in all applications in which metal contact with the mobile phase and or sample should be avoided. This valve uses PEEK vent lines and a Teflon® rotor seal and can be operated in a pH range from 0 – 14. Description Part No. 9725 Injection Valve for Series 200 Autosampler N9306020 Rheodyne ™ 8125 Low-Dispersion Stainless Steel Injection Valve Ideal for use in an LC/MS system, the model 8125 is designed for 1 and 2 mm microbore columns and can also be used with conventional analytical (3 to 5 mm) columns. Small flow passages produce low dispersion, maintaining the high mass sensitivity inherent in micro columns. Description Part No. 8125 Low-Dispersion Stainless Steel Injection Valve N9306021 Rheodyne ™ 7725 Analytical Injection Valve Inject from 1 μL to 5 mL with high accuracy and precision, with the Rheodyne™ 7725 and 7725i valves. Rheodyne™ 7725 and 7725i valves are versatile injectors and can use both partial-filling and complete-filling methods for loading the sample loop. Wide port angles of the 7725/7725i valve provide improved access to fittings. Sample loop with a 2 μL internal capacity is also available. In a clean system, the 7725/7725i typically can make more than 30,000 injections before requiring replacement of the rotor seal. Description Part No. 7725 Injection Valve for Series 200 Autosampler 7725i Injection Valve with Internal Switch N9306019 N9306017 See page 2 for ordering information and a complete listing of PerkinElmer offices. flow cells Interchangeable flowcells and pump accessory kits Bio Conversion Kits There are two kits available; one that contains all of the parts necessary to convert the Series 200 pump and Series 200 autosampler for Bio applications. The other contains all of the parts necessary to convert only the Series 200 Pump for Bio applications. Description Part No. S200 Pump and S200 Autosampler Conversion Kit S200 Pump Conversion Kit N2910035 N2910036 Pump Seal Kits N2910384 These flowcells provide the highest detection limits possible for your sample. The 6 mm pathlength flowcell has been optimized for lower-dispersion LC analysis and is the perfect choice when using narrowbore, 2.1 mm or microbore, 1 mm columns (see Figure 1). The 3 mm pathlength is the choice for semiprep LC to avoid detector saturation at high-solute concentrations. N2910345 UVVis, PDA and LC-135/235 FLOWCELLS Description Part No. High Pressure Piston Seal Replacement Kit Includes: Seals (4), Backup Rings and O-Rings Micropump Piston Seal Replacement Kit Includes: Seals and O-Rings Series 200 Pump Maintenance Kit Includes: Fuses, Seals, O-Rings and Seal Tools N2910383 Description Detector Backpressure Regulator The detector backpressure regulator is a device that is attached to the outlet of the detector to prevent outgassing in the flowcell, eliminating variations to the detector baseline. Detector Backpressure Regulator Description 40psi inline back pressure regulator 2 – 5K psi variable back pressure regulator Backpressure Regulator Adjustable from 15 – 59 psi Flexar UVVis, Series 200/785A UV/VIS, Flexar PDA and Series 200 EP Material Part No. Stainless Steel N2925090 N2925091 09907126 Part No. Flowcells for Flexar FX-UV/Vis UHPLC Detectors Flowcell 6 mm x 2.4 μL Flowcell Kit (includes flowcell 6 mm x 2.4 μL & detector head plate w/ gasket) Flowcells for Flexar FX-UV/Vis UHPLC Detectors Flowcell Assembly (w/ heat exchanger and zdv unions) 10 mm x 15 μL Flowcell 10 mm x 15 μL Flowcell Assembly (w/ zdv unions) 6 mm x 2.4 μL Prep Flowcell Assembly (w/ zdv unions) 3 mm x 1.7 μL Prep Flowcell 3 mm x 1.7 μL Flowcells for 785A UV/Vis Detectors Flowcell 8 mm x 12 μL Flowcell Assembly 8 mm x 12 μL (w/ heat exchanger and zdv unions) Flowcells for Flexar FX-PDA UHPLC and Series 275 PDA Detectors Flowcell (dual-lensed) 6 mm x 2.4 μL Flowcell Assembly (w/ mount) 6 mm x 2.4 μL Flowcells for Flexar and Series 200EP PDA Detectors Flowcell 10 mm x 15 μL Flowcell Asembly 10 mm x 15 μL Flowcells for Series 200 PDA Detectors Flowcell 10 mm x 12 μL Flowcell 4.5 mm x 5 μL Flowcells for LC-135/235 PDA Detectors Flowcell Assembly (w/ heat exchanger) 10 mm x 8 μL Flowcell 10 mm x 8 μL Order online at www.perkinelmer.com/supplies N2920127 N2920070 N2920125 N2920124 29000544 29000545 29000573 29000542 N2920117 N2920128 N2920166 N2920126 N2920160 N2922107 N2922030 N2350211 N2350162 ORDER TODAY 27 detector lamps For outstanding performance, use only PerkinElmer deuterium, tungsten or xenon HPLC lamps UV/VIS Deuterium Detector Lamp Series 200/200 EP Photo Diode Array Detector Lamp Our extensive quality control and inspection process demands the very best quality sources. Choosing a PerkinElmer deuterium, tungsten or xenon source provides outstanding ultraviolet and true visible performance. ■ Exceptional performance anywhere in the detector’s 190 – 700 nm wavelength range ■ Lamp changes are quick and easy due to a unique self-aligning lamp mount Photo Diode Array Detector Lamps The Flexar Series/Series 200/200 EP Photo Diode Array Detector provides true UV/VIS detection and high resolution spectral data. The excellent signal-to-noise characteristics make it ideally suited for low-volume or low concentration samples. Flexar/Series 200 EP UV/VIS Detector Lamps Components Part No. Deuterium Lamp Tungsten Lamp N2925030 N2922011 Series 200 Flexar Series/Series 200/785A UV/VIS Detector Lamps Components Part No. Deuterium Lamp Tungsten Lamp N2920149 N2920146 LC-295 UV/VIS Detector Lamps Components Part No. Deuterium Lamp 02712266 Components Part No. Deuterium Lamp (Phase 2) Tungsten Lamp N2922046 N2922011 LC-135C/235 Components Part No. Detector Lamp N2351285 Fluorescence Detector Lamps Refractive Index Detector Lamps The Flexar Series/Series 200/200s Refractive Index, with its deflection-type design, allows sensitive detection of these compounds with low noise and drift characteristics. Series 200/200a Components Part No. Tungsten Lamps 02712273 The major benefit afforded by fluorescence detection is the inherent high sensitivity of the technique coupled with outstanding specificity. The Series 200a Fluorescence Detector provides signal to noise ratio of >700:1 from trace analysis using a 150 W xenon source. Flexar/Series 200/200a Components Part No. Xenon Lamp N2922082 LC-240 For our complete listing of HPLC detector lamps, please visit: www.perkinelmer.com/lcsupplies 28 Components Part No. Xenon Lamp Festoon Lamp L2251157 04969486 See page 2 for ordering information and a complete listing of PerkinElmer offices. Nitrogen Generators PerkinElmer offers customers a new line of nitrogen generators to meet the growing need for cost effective and pure nitrogen. Membrane Nitrogen Generators are designed to supply single or multiple LC/MS instruments with dry nitrogen at purities of 98% to 99.5%. The generator can also be used for solvent evaporation as well as supplying dry nitrogen to analytical instruments. Features and Benefits ■ LC/MS grade purity enhances instrument performance ■ Phthalate-free ■ Recommended, certified, tested, and used by all major LC/MS instrument manufacturers ■ Return on investment in 6 months to 2 years ■ Minimal maintenance required LC/MS ■ Solvent Evaporation ■ Analytical instruments requiring nitrogen ■ Thermal Analyzers Part No. N9306210 Product Specification Purity: Atmospheric Dewpoint Particles >0.01 μm: Suspended liquids: Min./Max. operating pressure: Ambient operating temperature range: Inlet air temperature range: Maximum recommended inlet air temperature Electrical requirements: Dimensions (net): Weigh (shipping): 95.0 – 99.5% -58 °F (-50 °C) None None 60/145 psig (4.0/10 barg) 60 °F – 95 °F (15 °C – 35 °C) 60 °F – 95 °F (15 °C – 35 °C) 110 °F (43 °C) None 45 cm W x 41 cm D x 130 cm H 36 kg, 80 lbs Description N2-35 Mid Flow Nitrogen Generator without Air Compressor Applications ■ Description N2-22 Mid Flow Nitrogen Generator without Air Compressor Flow Rates* Inlet psi 100 125 100 125 100 125 Output Purity Ipm % 13 99.5 16 99.5 20 99.0 25 99.0 30 98.0 38 98.0 nitrogen generators Liquid Chromatography/ Mass Spectrometry Part No. N9306211 Product Specifications Low Flow NITROFLOW Lab Features and Benefits ■ Complete “Plug and Play” system recommended by all major LC/MS manufacturers ■ 8,000 hours compressor warranty or two years ■ Special design ensures quiet operation ■ Dual oil-less air compressors Components 120 V 230 V Part No. N9306213 N9306214 Product Specification Purity: Phthalate-free Hydrocarbon-free Flow Rates Delivery pressure Ambient temperature Power consumption Noise level Electrical requirements Lab capacity at nominal conditions: Ambient temperature: Ambient pressure: Dimensions (net): Weigh (shipping) 94.0 – 99.5% 10 – 50 lpm 8 bar 10 °C – 35 °C 1400 Watts <58 dB (A) 120 V / 60 Hz, 20 Amp Nema 5 20 °C/ 68 °F 1013 mbar(a). 90 cm W x 31 cm D x 70 cm H 127.4 kg, 280 lbs Purity: Atmospheric Dewpoint Particles >0.01 μm: Suspended liquids: Min./Max. operating pressure: Ambient operating temperature range: Inlet air temperature range: Maximum recommended inlet air temperature Electrical requirements: Dimensions (net): Weigh (shipping): 95.0 – 99.5% -58 °F (-50 °C) None None 60/145 psig (4.0/10 barg) 60 °F – 95 °F (15 °C – 35 °C) 60 °F – 95 °F (15 °C – 35 °C) 110 °F (43 °C) None 45 cm W x 41 cm D x 130 cm H 41 kg, 90 lbs Description N2-45 High Flow Nitrogen Generator without Air Oiless Compressor Flow Rates* Inlet psi 100 125 100 125 100 125 Output Purity Ipm % 20 99.5 25 99.5 30 99.0 37 99.0 46 98.0 57 98.0 Part No. N9306212 Product Specifications Purity: Hydrocarbon free Phthalate free Atmospheric Dewpoint Particles >0.01 μm: Suspended liquids: Min./Max. operating pressure: Recommended ambient operating temp range Inlet air temperature range: Maximum recommended inlet air temperature Inlet/Outlet ports Electrical requirements: Dimensions (net): Weigh (shipping): 95.0 – 99.5% -58 °F (-50 °C) None None 60/145 psig (4.0/10 barg) 72 °F (22 °C) 60 °F – 95 °F (15 °C – 35 °C) 110 °F (43 °C) 1/2” NPT None (filtration system only) 61 cm W x 50 cm D x140 cm H 114 kg, 250 lbs *See www.perkinelmer.com for complete listing of flow rates. Order online at www.perkinelmer.com/supplies Flow Rates* Inlet psi 100 125 100 125 100 125 Output Purity Ipm % 39 99.5 55 99.5 53 99.0 74 99.0 73 98.0 106 98.0 ORDER TODAY 29 c l a r u s 6 0 0 g a s c h r o m a t o g r a p h / S WA F E R MICRO-CHANNEL WAFER TECHNOLOGY Redefining Your GC Pathway PerkinElmer’s Swafer ™ PerkinElmer’s Swafer™ micro-channel wafer technology is an innovative and user-friendly approach for flowswitching and splitting applications – it delivers unparalleled hardware and application flexibility, expanding the capabilities of capillary gas chromatography (GC). Every fast-paced, high-volume laboratory shares a common goal: to speed up analytical cycle times. Now, PerkinElmer delivers with its latest innovation in GC, the high-performance Clarus ® 600 Gas Chromatograph. Clarus 600 Gas Chromatograph – the innovation is simply its speed Powered by the fastest available heat-up and cool-down conventional oven PerkinElmer has always led the way with innovations in gas chromatography and the Clarus 600 Gas Chromatograph (GC) is no exception. It features a unique, high-performance oven with the fastest combined heat-up and cool-down rate in a conventional GC oven design. Autosampler pre-rinse performs time-consuming syringe rinse with sample before the GC becomes ready, saving time in between runs. The resulting shorter injection-to-injection time will significantly increase your throughput and productivity by speeding up your analytical cycle time. And higher productivity means a fast return on your investment (ROI). QUICK GLANCE 30 SWAFER The fastest injection-to-injection time in conventional gas chromatography ■ Oven cool-down from 450 °C to 50 °C in less than 2 minutes ■ Integrated autosampler adds flexibility and automation ■ Temperature programmable inlets deliver performance and flexibility for more demanding applications ■ Programmable pneumatic control (PPC) adds automation efficiencies ■ Exclusive optional PreVent pressure-balanced system enhances performance and productivity ■ Innovative, intuitive touch-screen interface makes operation easy–no training required ■ Scalable TotalChrom CDS make data management and reporting easier than ever ■ PerkinElmer’s complete offering allows easy integration of best-in-class mass spectrometer, headspace, headspace trap or thermal desorption This exciting new technology can benefit most analytical laboratories. From simple techniques such as connecting two detectors to one column, and removing unwanted material from a column, to sophisticated multidimensional separations on complex samples, Swafer’s capabilities cover a wide range. Key Benefits: ■ Allows you to tackle difficult or otherwise impossible separations, delivering richer sample information which was previously unattainable ■ User-friendly design and user-defined oven position allow easy setup and configuration changes, without requiring service intervention ■ Complete independence of the column from injectors or detectors lets you combine injection techniques (headspace, thermal desorption, liquid, etc.), based on sample requirements ■ 15 user-interchangeable configurations deliver over 18 possible modes of operation for unparalleled application flexibility ■ Can be used on any Clarus 500 or 600 GC with programmable pneumatic control (PPC) See what the Swafer can do for you – www.perkinelmer.com/swafer Swafer Kits for New Clarus GC Systems Description Part No. D-Swafer Complete Kit – for new Clarus GC units only (for Clarus 600/500 GCs with PPC) Includes all required installation hardware, user guides, and the D-Swafer. S-Swafer Complete Kit – for new Clarus GC units only (for Clarus 600/500 GCs with PPC) Includes all required installation hardware, user guides, and the S-Swafer. N6520273 N6520272 Swafer Kits and Accessories for Existing Clarus GC Systems Description Part No. Micro-Channel Kit for Existing Clarus 600/500 GC (for Clarus 600/500 GCs with PPC) Includes all hardware required to install a Swafer. The Swafer and installation are not included and must be purchased separately. Micro-Channel Kit for Existing Clarus 600/500 GC with PreVent Currently Installed If PreVent is already included in the GC configuration, this hardware kit provides the additional parts required to install a Swafer. The Swafer and installation are not included and must be purchased separately. D-Swafer Dean’s Switch (Swafer only) S-Swafer Splitter (Swafer only) N6520270 See page 2 for ordering information and a complete listing of PerkinElmer offices. N6520271 N9306251 N9306262 Marathon Filament for PerkinElmer with GC/MS Systems Whatever you need it for the Clarus 600 GC/MS family delivers The compact Clarus 600 GC/MS, with its advanced electronics, features the widest mass range and best-in-class detection limits of any quadrupole MS. Our high-speed scanning delivers far better peak integrity and accuracy. Its gas chromatograph has the fastest heat-up and cool-down oven in a conventional GC. Multiple pumping options offer an instrument for every lab’s needs. Plus, the system is driven by our sample-centric TurboMass™ software for ease-of-use from data collection to evaluation and reporting. QUICK GLANCE ■ El and CI: best-in-class signal/noise specifications offer new possibilities for analysis ■ Plug-and-play ion source: loosen two screws and easily change when needed ■ Three pumping systems: provide the right performance to fit your needs and budget ■ Smaller footprint: for economical space use ■ Fastest scan rates (12,500 amu/sec): for the most accurate determination of peaks ■ Widest mass range (1 – 1,200 u): encompasses a variety of applications, such as brominated flame retardants ■ SIFI™ simultaneous collection of selected ion and full ion scanning data for the most productive analytical work ■ UltraTune™ automated tuning for BFB/DFTTP or custom tuning on any compound for faster setup A model for every lab’s needs: Clarus 600 C GC/MS: ■ Electron ionization and chemical ionization with 255 L/sec turbomolecular pump Clarus 600 T GC/MS: ■ The new Marathon™ Filament is a revolutionary, patent-pending technology developed exclusively by PerkinElmer, delivering long life even under the most difficult chromatography conditions. After lengthy performance testing and filament research, the new Marathon Filament has been engineered to provide exceptional long life and withstand difficult chromatography conditions. It has high resistance to demanding injections such as headspace or purge and trap and has stood up to challenging applications such as flame-retardant analysis. The Marathon Filament is a direct replacement of the previous rhenium filament – no system changes required. At PerkinElmer, we understand your challenges and are committed to providing the best solutions to make your life easier – the new Marathon Filament is part of our ongoing efforts to deliver the latest technology for our PerkinElmer GC/MS platform. Features and Benefits: ■ Long life even under the most difficult chromatography conditions ■ Unique white surface engineered for maximum durability and optimum performance ■ Now included with all new Clarus® GC/MS systems (560 and 600 series) ■ Backward compatible with all units using rhenium filaments ■ Works with both electron and chemical ionization sources Description Part No. Marathon Filament for PerkinElmer GC/MS Systems N6470012 clarus 600/560 gas chromatograph/Marathon Filament Get results better and faster with the NEW Clarus 600/560 Family of GC/MS Electron ionization with 255 L/sec turbomolecular pump Clarus 600/560 S GC/MS: ■ Electron ionization with 75 L/sec turbomolecular pump Clarus 600/560 D GC/MS: ■ To view the webcast and to order your replacement filament, visit: www.perkinelmer.com/MarathonFilament Electron ionization with air-cooled oil diffusion pump Order online at www.perkinelmer.com/supplies ORDER TODAY 31 Organic Standards from PerkinElmer GC and GC/MS Organic Calibration Standards For customer ease, all Organic Standards are prepared with a precision of +/- 0.5% and accompanied with a comprehensive Certificate of Analysis (lot specified by part number). Data packs are also available upon request. These include a chromatogram of the standard and quantitative report listing the values for each analyte. Method 8260B for Water and Solid Waste Matrices PerkinElmer offers a wide selection of GC and GC/MS standards. Each solution is supplied with a comprehensive Certificate of Analysis that documents quality and assurance to the highest level obtainable by a Calibration Standard. Organic Certified Reference Materials from PerkinElmer are a new addition to an already extensive organic product line, designed to enhance your one-stop shopping experience. Each new standard is provided in convenient 1.2 mL ampules to minimize waste and comes with a pre-labeled amber glass storage vial with cap for easy use. To ensure customer satisfaction, our Organic Mixes are prepared at concentration levels that take into consideration a number of factors including: vapor pressure, evaporation, breakdown rates and dilution schemes. PerkinElmer goes the extra step by analyzing each organic standard on the Clarus 600 GC and GC/MS state-of-the-art instrumentation, to ensure that the standard conforms to the customer’s exact needs. 600 Series Wastewater Methods Clean Water Act “Wastewaters” Interferene Volatile Organics CheckCombination Standards Blend Contains all analytes in Mixes A, C and D. Method SW-846 is an analytical method which utilizes a Clarus 600 GC to perform the separation of the volatile organic components found in a variety of solid waste matrices. To detect the GC eluant a Clarus 600 GC/MS is used. Description Part No. 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331047 Description Contains: N9331060, N9331061, N9331062, 9331063. Description Part No. 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331064 Mix A for Method 624 N9331060 Purgeable Gases Mix B for Method 624 Part No. Alternate Four-Component Surrogate Standard for Method 8260B 1.2 mL @ 2,000 μg/mL in P & T Methanol The U.S. EPA Method 624 is an analytical method which utilizes a TurboMatrix Headspace Purge and Trap instrument for sample prep and a Clarus 600 GC equipped with a packed column to perform the separation of the volatile organic compounds found in a 5 mL sample of municipal or industrial wastewater. To detect the eluant a Clarus 60 GC/MS is used. 1.2 mL @ 2,000 μg/mL in P & T Methanol Method 524.2 is an analytical method that uses a purge and trap device for sample preparation and a GC/MS equipped with a capillary column to perform the separation of volatile organic compounds. Interferene Method 8260B Check Standards Standards Method 624 Standards Kit for Volatile Organic Compounds 1.2 mL @ 2,000 μg/mL in P & T Methanol Method 8260B is an analytical method that uses a GC/MS equipped with a capillary column to perform the separation of the volatile organic compounds found in water and a variety of solid waste matrices. N9331042 Internal Standard for Method 8260B 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331041 Interferene Ketones for Check MethodStandards 8260B Description Part No. 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331043 N9331061 Mix C for Method 624 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331062 Mix D for Method 624 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331063 For a full product listing of NEW PerkinElmer GC Standards please visit: www.perkinelmer.com/gcsupplies 32 Mix B Purgeable Interferene CheckGases Standards for Methods 8260B/524.2 Description Part No. 1.2 mL @ 2,000 μg/mL in P & T Methanol N9331048 See page 2 for ordering information and a complete listing of PerkinElmer offices. Merlin MicroSeal™ and SilTite™ ferrules Merlin MicroSeal ™ Septum The Merlin MicroSeal™ septa is a unique replacement septa employing a two-step sealing system and an advanced elastomer material. SilTite™ metal ferrules provide a continuous leak-free connection and are perfect for connecting your column to a GC/MS. The SilTite™ metal ferrule and nut are manufactured from the same material and therefore expand and contract at the same rate, eliminating the need to retighten, even after temperature cycling. The base of the SilTite™ ferrule forms a perfect seal with the MS interface, ensuring a leak-free connection. SilTite™ metal ferrules have a temperature limit well above the temperature capacity of the injector, MS interface or GC oven. Description Hole Size SilTite™ Ferrules Starter Kit (pkg. 10) SilTite™ Ferrules Starter Kit (pkg. 10) SilTite™ Ferrules Starter Kit (pkg. 10) SilTite™ Ferrules (pkg. 10) SilTite™ Ferrules (pkg. 10) SilTite™ Ferrules (pkg. 10) SilTite™ Nuts (pkg. 5) 0.4 mm 0.5 mm 0.8 mm 0.4 mm 0.5 mm 0.8 mm Part No. N9306090 N9306091 N9306092 N9306093 N9306094 N9306095 N9306096 Capillary Column Ferrules Graphite Ferrule of choice for high-temperature applications up to 450 °C. Graphite seals easily and does not stick to glass columns. Because the syringe needle does not pierce the septa, there is no debris and ghost peaks are greatly reduced. The MicroSeal™ septa also reduces the incidence of bent syringe needles and liner contamination. Usable in either manual or autosampler applications, this septa can improve your productivity and run reliability. Designed to be used with 23 gauge straight needle syringes. Pressure ranges from 4 to 100 psi and injection port temperatures up to 325 °C. Features and Benefits ■ Thousands of injections before septa change ■ 2-step sealing system ■ No debris — no ghost peaks ■ Temperatures up to 325 °C ■ Pressure ranges 4 to 100 psi Description Pkg. Merlin MicroSeal™ Septum Kit Includes: Injector Port Adapter, 2 Septa and 1 Nut Merlin MicroSeal™ Septum Part No. N9303344 1 N9303345 Injector Septa ■ 15% graphite/85% polyimide ferrule recommended for use with GC/MS systems. Temperature limit 350 °C. Thermogreen® LB-2 septum, extremely low bleed over a wide range of inlet temperatures — 100 to 350 °C. Easier needle penetration and high puncture tolerance make this septum ideal for autosamplers. This septum is already conditioned and ready to use ■ BTO™ (Bleed Temperature Optimized) injector septa, 11 mm diameter. Maximum recommended operating temperature 300 °C Vespel® ■ PTFE/Silicone injector septa, 11 mm diameter Graphite/Vespel® Not reusable. Not recommended for fused silica capillary columns. Use these ferrules on 1⁄16 inch metal tubing and glass-lined receivers. Temperature limit 350 °C. Capillary Column Ferrules Nut Size Column i.d. / Ferrule i.d. Graphite Part No. ⁄16 in 1 ⁄16 in 1 ⁄16 in 1 ⁄16 in 1 ⁄8 in 1 ⁄8 in 1 ⁄8 in 0.18 – 0.25 mm / 0.4 mm 0.18 – 0.32 mm / 0.5 mm 0.18 – 0.32 mm / 0.5 mm* 0.18 – 0.53 mm / 0.8 mm 0.18 – 0.53 mm / 1.0 mm 0.18 – 0.32 mm / 0.5 mm* 0.18 – 0.32 mm / 0.5 mm 09903700 N9306001 09920141 09903394 09903395 09903981 1 *2-hole Graphite/Vespel® Part No. 09920104 09920105 N9306000 09920107 Description Pkg. Part No. 50 N6621028 Thermogreen Injector Septa Low Bleed Injector Septa 25 N9303343 PTFE/Silicone Injector Septa 50 00090652 Green Injection Port Septa 10 N9306218 Green Injection Port Septa 50 N9306219 Orange Injection Port Septa 50 N9302972 Green Septa Rated to 400 °C The Advanced Green Septum was created to combine significantly longer injection life, low bleed and low injection port adhesion. The result is a general use green septum made of uniquely formulated silicone rubber you can use for all your daily analyses. Packaged in a pre-cleaned glass screw top jar for high purity. Orange Septa Rated to 400 °C Uniquely Formulated Silicone Rubber Septa BTO® is Bleed and Temperature Optimized for today’s most demanding GC and GC/MS applications. Septa BTO® is formulated to extend low-bleed and outstanding mechanical properties of premium GC septa. It retains remarkable softness at high temperatures and has been optimized to reduce injection port adhesion. Packaged in a precleaned glass screw top jar for high purity. ® Order online at www.perkinelmer.com/supplies ORDER TODAY 33 Inline Gas Purifiers for Clarus GC and Fast and easy to use Click-On Inline Super Clean™ Gas Purifiers save you time and money PerkinElmer Click-On Inline Super Clean ™ Purifiers reduce your maintenance system downtime Using the Click-On Connectors lets you change the trap without introducing contaminant’s into your system. Click-On connectors can replace a trap, without introducing impurities into the system. This in turn eliminates the need to flush the system. The unique Click-On Connector fitting has a spring-loaded needle valve, which seals when a trap is removed and only opens when a new trap is connected and locked into position. When the Click-On connectors are installed into the gas line, there is no need to loosen or tighten any fittings, simply click on the new trap in seconds. The ability to add a Click-On Inline Super Clean™ Indicator after the stainless steel trap gives the user a clear visual indication of when to change the filter. This indicator may also be used as a standalone trap. Click-On Inline Purifier Compatibility Chart Type of Gas Reduce system downtime with Click-On fast connectors ■ High purity ensures 99.9999% pure gas ■ No open gas line when changing the trap ■ Helium Specific Glass Indicating Triple Trap is ideal for GC/MS ■ No tools necessary to replace trap Oxygen Filter √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ Acetylene Air Carbon Dioxide Helium Hydrogen Methane Nitrogen Nitrous Oxide Oxygen Propane P5 Features and Benefits ■ Moisture Filter Hydrocarbons Combination Filter Filter √ √ √ √ √ √ √ √ √ √ √ √ Triple Filter √ √ √ √ √ √ √ √ (5% Methane in Argon) P10 (10% Methane in Argon) Product Specifications Purifier Type Gas Quality* Max. Pressure Max. Flow Use For H20 Moisture 99.9999% 11 bar, 160 psi 25 L/min Inert carrier gas He, Air, H2 21 g Capacity O2 NA Hydrocarbons > 3 years NA > 3 years Oxygen 99.9999% 11 bar, 160 psi 25 L/min Inert carrier gas NA 3,000 mL Hydrocarbons 99.9999% 11 bar, 160 psi 25 L/min Inert carrier gas Air, H2 NA NA 36 g (as n-butane) > 3 years Combination Moisture/ Hydrocarbons 99.9999% 11 bar, 160 psi 25 L/min Inert carrier gas He, Air, H2 10 g NA 18 g (as n-butane) > 2 years Indicating Triple Moisture/ Oxygen/Hydrocarbons 99.9999% 11 bar, 160 psi 25 L/min Inert carrier gas He 3g 400 mL 5 g (as n-butane) > 1 year Triple Moisture/ Oxygen/Hydrocarbons 99.9999% 11 bar, 160 psi 25 L/min Inert carrier gas 6g 1,000 mL 12 g (as n-butane) > 2 years *Results @ 2 L/min 34 Est. Lifetime NA See page 2 for ordering information and a complete listing of PerkinElmer offices. GC/MS 3-Cartridge Gas Purification System Stainless Steel Trap Kits Description Connector (Qty) Part No. Combination: Oxygen/Moisture Trap Combination: Oxygen/Moisture Trap Combination: Moisture/Hydrocarbons Trap Combination: Moisture/Hydrocarbons Trap Triple: Oxygen/Moisture/Hydrocarbons Trap Triple: Oxygen/Moisture/Hydrocarbons Trap Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons 1 ⁄8" Brass (2) 1 ⁄8" SS (2) 1 ⁄8" Brass (2) 1 ⁄8" SS (2) 1 ⁄8" Brass (2) 1 ⁄8" SS (2) 1 ⁄8" Brass (2) N9306108 N9306109 N9306117 N9306118 N9306110 N9306111 N9306112 ⁄8" SS (2) N9306113 1 Stainless Steel Traps Description Part No. Moisture Trap Oxygen Trap Hydrocarbons Trap Combination: Oxygen/Moisture Trap Combination: Moisture/Hydrocarbons Trap Triple: Oxygen/Moisture/Hydrocarbons Trap Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons N9306100 N9306101 N9306102 N9306103 N9306105 N9306104 N9306106 Helium Specific Glass Indicating Triple Trap for your PerkinElmer Clarus GC/MS PerkinElmer recommends the use of the Helium Specific Glass Indicating Triple Trap for your GC/MS system. This trap contains oxygen, moisture and hydrocarbons adsorbents in one trap and is packed and purged under helium. The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute for cobalt dioxide (blue) in the moisture indicator. Available as a kit with the necessary 1⁄8" brass connectors, and as a replacement trap, this system is easy to install. Description Connector (Qty) Indicating Glass Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons Indicating Glass Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons Indicating Glass Triple Gas Specific (He): Oxygen/Moisture/Hydrocarbons Part No. N9306107 ⁄8" Brass (2)* N9306114 ⁄8" SS (2) N9306116 1 1 AFS Manifold and Mounting Hardware Advanced Filter System The Advanced Filter System has high capacity and efficiency levels for oxygen, water and hydrocarbons. The recommended maximum flow rate is 2.0 L/min and 200 psi maximum operating pressure. Features and Benefits Advanced Filter System ■ Two indicators, for oxygen and moisture ■ Easy cartridge replacement with on/off knob ■ Double seal construction for safety ■ Check valves protect gas lines during cartridge replacement System Capacity Efficiency Oxygen Water Hydrocarbns 850 cc 12 g 8g < 1 ppb < 10 ppb < 1 ppb A polycarbonate shield surrounds the glass indicator section of the filter is sealed, unlike other gas filters, the gas flow is secure even if the glass should break. This redundant sealing system and robust construction provides a new level of security in gas filtration. Maximum flow rate is 2.0 L/min with 200 psi max operating pressure. Description Part No. Advanced Filter System (manifold and mounting hardware included) Replacement Cartridge Manifold and Mounting Hardware N9303963 N9303964 N9306139 3-Cartridge Gas Purification System This system provides for high capacity contaminant removal for GC supply gasses, and allows for individual cartridge replacement. Cartridge replacement is recommended after processing 19 cylinders of 8 m3 high purity gas (99.997%). Features and Benefits Special Saving Offers from PerkinElmer! Please contact your local PERKINELMER sales office for additional details ■ All stainless steel cartridges are easy to replace ■ High capacity ■ Wall bracket gets the system up and out of the way System Capacity Efficiency Oxygen Water Hydrocarbons (C5 and higher) 1,000 cc 25 g 19 g < 1 ppb < 30 ppb < 1 ppb Description Part No. Purification System, 3 Head All Steel System Cartridge Set, Gas Purification All System Cart (Replacement) Cartridge, Gas Purification Moisture Cartridge, Gas Purification Hydrocarbon Cartridge, High Capacity O2 Replacement Hardware, Gas Purification Manifold/Mtg Hardware, Gas Purification Manifold/Mtg for bench or wall N9306135 N9306136 N9306137 N9306138 N9306004 N9306140 N9306014 Order online at www.perkinelmer.com/supplies ORDER TODAY 35 gc supplies Essential GC lab supplies from PerkinElmer MiniTemp MT4 Non-contact Temperature Measurement with Laser Sighting Features and Benefits Portable Gas Leak Detector The new PerkinElmer compact handheld electronic gas leak detector is the ideal solution for detecting gas leaks in your Gas Chromatography systems. Leaks in your system waste gas and can cause detector noise, baseline instability, and shorter column life. This portable unit detects minute leaks of any gas with thermal conductivity different from air. The reference gas inlet draws in ambient air for comparison to air drawn into the sample probe. A leak is detected by both LED bar graph display and audible alarm. ■ Displays thermal measurement readings in °C or °F ■ Easy point and shot infrared technology in a pocket size configuration ■ Great for instrument thermal test confirmation, including GC injector port and detector measurements, thermostatted LC vials, and enzymatic hydrolysis baths Non-contact Surface Temperature Measurement with Laser Sighting Specifications Model MiniTemp MT4 Temperature Range -18 to 400 °C (0 to 750 °F) Distance to Spot Size (D:S) 8:1 Response time 500 m/sec Detectable Gases Gas Type Minimum Detectable Leak Rate (atm cc / sec) Helium Hydrogen** Nitrogen Argon Carbon Dioxide 1.0 x 10-5 1.0 x 10-5 1.4 x 10-3 1.0 x 10-4 1.0 x 10-4 Indicating LED Light Color Red Red Yellow Yellow Yellow Battery: Rechargeable Ni-MH internal battery pack (6 hours normal operation) Universal Power Adapter Set: US, UK, European, Australian plugs included Operating Temperature Range: 32 – 120 °F (0 – 48 °C) Humidity Range: 0 – 97% Warranty: 1 Year Certifications: CE, Japan Compliance: WEEE, ROHS Features and Benefits ■ Sleek ergonomic, hand-held design with rugged side grips ■ Automatic shut-off capabilities ■ Optimized sample flow path ■ LED readout and audible alarm Pre-set at 0.95 Accuracy ±2%, or ±2°C (±3 °F) whichever is greater Typical Distance to Target (Spot) Up to 1.5 m (4 ft) Laser Sighting Yes The popular MiniTemp MT4 also includes single dot laser sighting to assist with aiming. 9 volt battery included. Recalibration is not available. Description Part No. MiniTemp MT4 N9306074 Basic Tool Kit Description Part No. Tools come in a tool box for easy storage and use N9301327 Kit Includes: Open-end Wrench Set (6 pc), Screwdriver Set (6 pc.), Adjustable Wrench (6 in), Chain Nose Pliers (narrow), Wire Cutters, and Wire Strippers Deluxe Tool Kit Description Part No. Portable Electronic Leak Detector Soft Carrying Case Probe (fine tip) N9306089 N9306142 N9306063 **Caution: The PerkinElmer leak detector is not designed for determining leaks in a combustible environment. This unit may be used for determining trace amounts of hydrogen in a GC environment only. 36 Emissivity Description Part No. Shipped in a plastic tool box for convenient storage N9301328 Kit Includes: Open-end Wrench Set (6 pc.), Screwdriver Set (6 pc.), Adjustable Wrench (6 in), Chain Nose Pliers (narrow), Wire Cutters, Wire Strippers, Slip-joint Pliers (6 in), Long Nose No. 5 Stainless Steel Tweezers (43⁄8 inches), Needle File Set (6 pc.), Allen Key Set (11 pc. imperial sizes), and Allen Key Set (9 pc. metric sizes) See page 2 for ordering information and a complete listing of PerkinElmer offices. flow meters Flow Meters Digital Bubble Flow Meter The PerkinElmer Model 520 is a volumetric flow meter. It can measure the flow rate of any gas or combination of gases, such as air, without adjustment. The flow meter has a digital display and a single push-button input. It is made of stainless steel and anodized aluminum. It comes with a certificate of calibration, and is accurate to +/- 3%. The Model 520 can measure flow rates of 0.5 to 500 mL/min. Features and Benefits ■ 0.5 to 500 mL/min flow rate ■ Digital Display ■ Volumetric flow measurement ■ 9 V battery operation (included) ■ Digital Display ■ Accurate to +/- 3% of measured flow rate Description Part No. Digital Bubble Flow Meter Replacement Glass for Digital Bubble Flow Meter N9302974 N9033429 PerkinElmer Electronic Flowmeter 1000 The PerkinElmer Flowmeter 1000 allows for rapid real-time flow measurements. Flow rates measured in mL/min. (volumetric flow). The PerkinElmer Flowmeter 1000 can quickly calculate split ratios. Ratios are displayed in real time. Flowmeter not compatible with corrosive or flammable gases. Portable operation. (9V battery included). Features and Benefits PerkinElmer FlowMark ™ Electronic Flowmeter PerkinElmer’s FlowMark™ flowmeter is specifically designed for use with gas chromatography (GC) instruments. The probe is applied directly to the gas flow stream and the measured flow rate is presented on the LCD screen. Units of flow are measured in mL/min. This unit provides continuous real-time measurements of gas streams ranging from 0.50 mL/min to 500 mL/min. Because the technology uses volumetric flow measurement, the unit is compatible with all laboratory gases. The flowmeter is designed to measure clean, dry, non-corrosive gases. Features and Benefits ■ Measures volumetric flow for all gases across a range of 0.5 – 500 mL/min. Operating Temperature 0 to 45 °C ■ NIST traceable calibrationy Traceable to NST Primary Standard ■ Explosion-proof rating for flammable and explosive gases ■ Split Ratio Mode ■ Accuracy of ± 2% of flow or ± 0.05 mL/min., whichever is greater ■ Accuracy +/- 3% ■ Over range indicator ■ LCD Alphanumeric Display ■ Auto shut-off feature ■ Ergonomic design and side grips for comfort ■ Measures most gas types ■ Convenient storage case included ■ CE, Ex (Compliance:WEEE, RoHS) certified ■ Uses 2-AA batteries ■ Data output via USB port ■ Re-calibration service available ■ Operating Temp. Range: 32 – 120 °F (0 – 48 °C) ■ 1 year warranty ■ Flow range 0.1 – 1000mL/min. ■ ■ Description Part No. PerkinElmer Electronic Flowmeter 1000 N9307029 Soap Bubble Flow Meters The glass soap bubble flow meters are calibrated in 1 and 10 mL two-stage or 1, 10 and 100 mL three-stage for easy flow reading. Bubble meters come complete with liquid soap, rubber squeeze bulb, miscellaneous-sized plastic tube pieces to adapt to various fittings, and instructions (stand required, but not included – N9303314). Description Part No. Two-stage Three-stage Stand 00230522 N9300081 N9303314 Description Part No. FlowMark Electronic Flowmeter Soft Carrying Case N9307086 N9306142 ™ Order online at www.perkinelmer.com/supplies ORDER TODAY 37 syringes GC injector and autosampler syringes New Blue Barrel color design for enhanced sample volume verification (packs of 5 and 10 syringes) Point Style 2 This is a general purpose point style designed for septum penetration in all chromatographic techniques. The needle has a 22° bevel to minimize coring and needle plugging. Autosampler Syringes Syringes from PerkinElmer are individually inspected for accuracy and performance. Recommended autosampler syringes are available in 0.5, 5 and 50 μL capacities. For routine analyses, the metal plunger in barrel with PTFE-tipped seal is the standard syringe as shipped with each Clarus® GC instrument. Alternative syringes to use are the metal plunger in barrel or the 0.53 mm on-column injection. Description Part No. 50 μL Syringe, Metal Plunger 0.63 mm o.d. needle 5 μL Syringe, Metal Plunger PTFE-tipped Seal 0.63 mm o.d. needle 5 μL Syringe, Metal Plunger PTFE-tipped Seal 0.63 mm o.d. needle BLUE Barrel (pack of 5 syringes) 5 μL Syringe, Metal Plunger PTFE-tipped Seal 0.63 mm o.d. needle BLUE Barrel (pack of 10 syringes) 5 μL Syringe, Metal Plunger 0.63 mm o.d needle 5 μL On-column Syringe Metal Plunger 0.47 mm o.d needle 0.5 μL Low Injection Volume Syringe, Metal Plunger 0.63 mm o.d. needle 0.5 μL Low Injection Volume Syringe Metal Plunger 0.63 mm o.d. needle BLUE Barrel (pack of 5 syringes) 0.5 μL Low Injection Volume Syringe Metal Plunger 0.63 mm o.d. needle BLUE Barrel (pack of 10 syringes) 0.5 μL Low Injection Volume Syringe, Metal Plunger 0.47 mm o.d. needle N6101760 N6101390 † 38 25 22 26† 25 1 1 1 1 Recommended for PerkinElmer wide-bore capillary adapter ■ A 7 cm needle is critical to be sure your sample is deposited in the optimal zone Syringe Capacity N6101252 10 μL 25 μL 50 μL 100 μL N6103242 N6103243 N6101253 Point Style Gauge Length Pack Size Point Style 1 1 1 1 #2 #2 #2 #2 Part No. N9302210 N9302211 N9302212 N9302213 Replacement Needles for RN Syringes Syringe Capacity 10 μL 25/50/100 μL 250 μL Syringes come standard with needle length of 7 cm — optimum for PerkinElmer injectors 0.5 μL 1.0 μL 1.0 μL 2.0 μL All PerkinElmer injectors have been tested and optimized for use with a 7 cm needle Removable Needle Syringes (RN) ■ Pack Size ■ N6101251 N6101380 Recommended for liquid sample injections of less than 5 μL for gas chromatography Length GC Injector Syringes N6103241 Ultramicro Volume Syringes Gauge Needle has a 90° bevel. Point style is recommended when the syringe is used for accurate pipetting of liquids. Excellent for mixing standards of very small volume. N6103240 ■ Syringe Capacity Point Style 3 Gauge Length Pack Size Point Style 26S 22S 22S 2 in 2 in 2 in 3 3 3 #2 #2 #2 Length Pack Size Point Style 1 6 1 1 1 1 #2 #2 #2 #3 #2 #3 Part No. N9302222 N9302224 N9302226 Fixed Needle Syringes Part No. N9302231 00230177 00230111 N9302235 Syringe Capacity 10 μL** 10 μL* 25 μL 25 μL 50 μL 50 μL Gauge *Savings based on one-piece price. Savings of 20% reflected in price shown. **Standard fitted with 7 cm needle. See page 2 for ordering information and a complete listing of PerkinElmer offices. Part No. 00230523 N9302230 N9302202 09904823 N9302203 09904941 Programmed Temperature Split/Splitless (PSS) Injector Liners Dimensions (mm) i.d. x o.d. x length Description Pkg. Part No. Quartz Split Liner PerkinElmer Standard (ships in instrument) 2 x 4 x 86.2 1 N6121004 Quartz Split Liner with Silanized Glass Wool 2 x 4 x 86.2 1 N6121008 Quartz Split Liner with Silanized Glass Wool 2 x 4 x 86.2 5 N6121009 Quartz Splitless Liner Excellent for low-volume analysis (ships with instrument) 1 x 4 x 86.2 1 N6121006 2.4 x 4 x 86.2 1 N6101539 2 x 4 x 86.2 5 N9302949 On-Column Glass Liner Borosilicate Glass Split Liner This liner is loosely packed with wool for the specific use of analyzing fuel in oil glass inlet liners Glass Inlet Liners for PerkinElmer Injector Systems Capillary Split/Splitless Injector Liners Dimensions (mm) i.d. x o.d. x length Description Pkg. Part No. Quartz Liner for Split Operation Good for large volume injections 4 x 6.2 x 92.1 1 N6121001 Quartz Liner for Split Operations with Silanized Glass Wool Good for large volume injection 4 x 6.2 x 92.1 1 N6121010 Quartz Liner for Split Operations with Silanized Glass Wool Good for large volume injection 4 x 6.2 x 92.1 5 N6121011 Quartz Liner for Splitless Operation Standard Injector Liner (ships with instrument) 2 x 6.2 x 92.1 1 N6121002 Glass Liner for Split Operation Universal liner for general purpose analysis 4 x 6.2 x 92.1 1 N6101052 Glass Liner for Splitless Operation Universal liner for general purpose analysis 2 x 6.2 x 92.1 1 N6101372 Precision Split Glass Liner Deactivated Surface with wool Wool can be adsorptive if fibers are broken 4 x 6.2 x 92.1 5 N6121020 Zero Dilution Glass Outer Liner Ideal for trace headspace work 2.7 x 6.3 x 69 1 N1011445 1 x 2 x 73 1 N1011446 Zero Dilution Inner Liner Use with Outer Liner (N1011445) Packed Column Injector Liners Dimensions (mm) i.d. x o.d. x length Description Wide-Bore Column On/Off Quartz Liner Wide-Bore Column Glass Liner 6 x 4 x 92.1 Pkg. Part No. 1 N6121003 6 x 4 x 92.1 1 N6101375 Drilled Uniliner (hole on bottom) NEW! Good for PPC equipped GCs. Recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. 4 x 6.2 x 92.1 5 N6502013 Gooseneck Drilled Uniliner (hole on top) NEW! Use for trace, active samples. Gives high recovery and linearity. 4 x 6.2 x 92.1 5 N6502014 Order online at www.perkinelmer.com/supplies ORDER TODAY 39 Autosamplers Vials, Caps and Septa Vials, Caps and Septa Kits from PerkinElmer PerkinElmer Supplies – Tested and Approved We have expanded our product selection to cover additional test applications and to make it easier for our customers to order prepackaged kits for their daily production requirements. Tested to meet your application requirements and guaranteed for fit and compatibility. AutosamplerCheck Interferene CrimpStandards and Screw Top Vials, Caps and Septa (continued) Description Autosampler Crimp and Screw Top Vials, Caps and Septa Our screw thread vials are custom designed for PerkinElmer Clarus GCs. Manufactured from Type 33 borosilicate glass, the vials have high-temperature tolerance and are chemically inert. Color variety crimp caps offer easy identification within the laboratory on 2 mL crimp top vials. Microsampling with a maximum capacity of 200 L can be accomplished with the use of a low-volume insert and support foot. ® Description Pkg. Part No. CRIMP TOP VIALS: (also see Convenience Kits for Additional Vials and Caps Sold Separately) 2 mL 11 mm Crimp Top Clear Glass Vials 2 mL 11 mm Crimp Top Amber Glass Vials ® ® ® ® ® 40 200-μL Low-Volume Clear Glass Insert Vial Support for Insert 09923032 09923031 N9306247 N9302780 N6101276 1000 500 N9302681 N9302682 100 N9300703 1 each N9300704 Use with: 10 mm 2 mL Amber Screw Top Vial w/ White “P’ Icon w/ Patch 10 mm 2 mL Clear Screw Top Vial w/ White “P” Icon w/ Patch 11 mm Clear Large Opening Snap Ring Vial w/ Black “P” Icon 11 mm Clear Large Opening Crimp Vial w/ Black “P” Icon 9 mm 2 mL Amber Screw Top Vial w/ Black “P” Icon 9 mm 2 mL Clear Screw Top Vial w/ Black “P” Icon N9306057 N9306053 N9303418 N9306231 N9306220 N9306201 LOW VOLUME VIAL GLASS INSERTS: 100 100 100 100 1000 N9302686 N9302684 N9302685 N9306015 N9302784 100 100 100 100 100 N9302945 N9303441 N9306201 N9306220 N9303442 100 100 N9303418 N9306207 100 N9306208 VIAL HOLDER RACKS: 100 100 100 N9303416 N9303417 N9303419 36-Vial Capacity 20 mm Vial Holder Rack 50-Vial Capacity 11 mm Vial Holder Rack SNAP TOP VIALS/CAPS/SEPTA: 2 mL 11 mm Clear Snap Wide Opening Vials 2 mL 11 mm Clear Snap Wide Opening Vials with Write-On Patch and Fill Lines 2 mL 11 mm Amber Snap Wide Opening Vials with Write-On Patch and Fill Lines 11 mm Pre-slit PTFE/Silicone Snap Caps 11 mm Pre-slit PTFE/Silicone/PTFE Snap Caps 11 mm PTFE/Silicone Snap Caps Part No. INSERTS: N9301385 N9302680 SCREW TOP VIALS/CAPS/SEPTA: 2 mL 8 mm Screw Top Clear Glass Vials 8 mm Screw Caps 2 mL 9 mm Screw Top Clear Vials 2 mL 9 mm Screw Top Amber Vials PTFE-Coated Butyl Rubber Septa for 8 mm Screw Top Vials Cap for Waste and Wash Vials (15 mm) 1 each Clear Waste and Wash Vial 4 mL (15 mm) 1 each Clear Waste and Wash Vial 4 mL (15 mm) 100 Septa for Waste Wash Vials (for use with 50 Viscous or Toxic Samples) Diffusers for Waste and Wash Vials 1 Diffusers are sold exclusively by PerkinElmer. The conical shape allows theneedle to penetrate into solvent or waste. Reduces spillage and large losses through evaporation. 100 100 CRIMP TOP SEPTA: 11 mm Blue Crimp Caps with Teflon Rubber Septa 11 mm Green Crimp Caps with Teflon Rubber Septa 11 mm Red Crimp Caps with Teflon Rubber Septa 11 mm Silver Crimp Caps with Teflon Rubber Septa 11 mm Silver Crimp Caps with Black Viton Septa Pkg. WASTE AND WASH VIALS/CAPS: 6 mm x 29 mm Clear Glass Insert, Rimless Pulled Point with Bottom Spring, 250 μL Usable Volume 6 mm x 31 mm Clear Glass Flat Bottom Insert, 400 μL Usable Volume 5 mm x 29 mm Clear Glass Insert Rimless Pulled Point with Bottom Spring, 250 μL Usable Volume 5 mm x 31 mm Clear Glass Flat Bottom Insert, 200 μL Usable Volume 100 N9300705 100 N9300706 Use with: 11 mm Standard Amber Crimp Vial w/ Black “P” Icon 11 mm Standard Clear Crimp Vial w/ Black “P” Icon 8 mm 2 mL Clear Screw Top Vial w/ Black “P” Icon N9302680 N9301385 N9302945 1 1 See New Convenience Kits for Additional Vials, Caps and Septa See page 2 for ordering information and a complete listing of PerkinElmer offices. N9301304 N9301303 Kits Crimping Tools and Kits Crimping Tools Whatever your need may be, PerkinElmer offers a wide range of crimping tools for your convenience. Our universal voltage, precision control, power crimpers with adjustable settings are designed to deliver hundreds of crimps on a single battery charge. Description Pkg. Part No. 1 1 1 1 1 1 N9306127 00090699 N9301390 N9301270 N6221006 N6621008 1 N9302594 1 N9302595 1 N9302592 1 N9302593 1 1 N9302585 N9302596 Pkg. Part No. HAND HELD AND BENCH-TOP CRIMPERS: 8 mm Hand Crimper 11 mm Hand Crimper 11 mm Hand Decapper 20 mm Hand Decapper Bench-top Vial Crimper 11 mm Crimper Jaws Autosampler Vials/Caps/Septa Kits PerkinElmer understands your challenges and offers a variety of kits so that you can easily order and restock your laboratory supplies. Description Pkg. Part No. Autosampler Starter Kit Crimper Tool (Pkg/1) Syringe 9000 5.0 μL 0.63 mm o.d. (Pkg/1) Vial Rack for 50 Vials 12 mm (Pkg/1) 2 mL 11 mm Crimp Top Vial, Clear (Pkg/100) Decapper 11 mm Tool (Pkg/1) 2 mL Crimp Top Vial, Amber (Pkg/100) 11 mm Crimp Cap, Green w/ Septa 11 mm Crimp Cap, Red w/ Septa (Pkg/100) 11 mm Crimp Cap, Blue w/ Septa (Pkg/100) Septa for Waste/Wash Vials (Pkg/50) 11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100) 1 1 1 1 1 1 1 1 1 1 2 1 N6120105 00090699 N6101390 N9301303 N9301385 N9301390 N9302680 N9302684 N9302685 N9302686 N9302780 N9306015 GC Educational Consumables Kit With Electronic Crimper Crimper Tool 11 mm Electronic Hand Crimper w/ Battery (Pkg/1) Syringe 5.0 μL 0.63 mm o.d. (Pkg/1) Rack for 50 Vials 12 mm (Pkg/1) 11 mm Crimp Top Vial, 2 mL (Pkg/100) 11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100) Elite™ Column – 5-30 M x 0.25 μm x 0.25 mm (Pkg/1) 1 1 2 1 2 2 1 N6500570 N9302592 N6101390 N9301303 N9301385 N9306015 N9316076 GC Educational Consumables Kit With Manual Crimper Hand Crimper Tool (Pkg/1) Syringe 5.0 μL 0.63 mm o.d. (Pkg/1) Rack for 50 Vials, 12 mm (Pkg/1) 11 mm Crimp Top Vial, 2 mL (Pkg/100) 11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100) Elite Column – 5-30 M x 0.25 m x 0.25 mm (Pkg/1) 1 2 2 2 2 2 1 N6500571 00090699 N6101390 N9301303 N9301385 N9306015 N9316076 Screw Top Autosampler Vial Convenience Kit – Pkg/100 1 2 mL 8 mm Clear Screw Top Vials (Pkg/100) 8 mm Black Caps w/ Preassembled PTFE/Rubber Septa (Pkg/100) Packed in a Environmentally Clean, Re-sealable Clamshell Pack N9301945 Crimp Top Autosampler Vial Convenience Kit – Pkg/100 2 mL 11 mm Clear Crimp Top Vials (Pkg/100) 11 mm Silver Caps w/ Preassembled PTFE/Rubber Septa (Pkg/100)Packed in a Environmentally Clean, Re-sealable Clamshell Pack N9300654 N9301385 N9306015 1 1 1 ELECTRONIC CRIMPERS: 20 mm Electronic Universal Crimper with Global Mains Plug Pack 20 mm Electronic Universal Decapper with Global Mains Plug Pack 11 mm Electronic Universal Crimper with Global Mains Plug Pack 11 mm Electronic Universal Decapper with Global Mains Plug Pack Electronic Crimper Battery Rechargeable Battery Easy-to-Order Convenience Kits Description 11 mm Red Rubber Crimp Convenience Kit – Pkg/100 11 mm Red Rubber/Silver Crimp Assembly (Pkg/100) 11 mm Clear 2 mL Vial Kit (Pkg/100) 1 1 1 N9300502 N9306230 N9306231 11 mm Red Rubber Crimp Convenience Kit – Pkg/500 11 mm Red Rubber/Silver Crimp Assembly (Pkg/100) 11 mm Clear 2 mL Vial Kit (Pkg/100) 1 5 5 N9300503 N9306230 N9306231 11 mm PTFE/SIL Crimp Convience Kit – Pkg/100 11 mm PTFE/Sil Crimp Assembly (Pkg/100) 11 mm Clear 2 mL Vial Kit (Pkg/100) 1 1 1 N9300500 N9306228 N9306231 11 mm PTFE/SIL/PTFE Crimp Convenience Kit – Pkg/100 11 mm PTFE/Sil/PTFE Crimp Assembly (Pkg/100) 11 mm Clear 2 mL Vial Kit (Pkg/100 ) 1 1 1 N9300501 N9306229 N9306231 9 mm Red Rubber Screw Cap Convenience Kit – Pkg/100 9 mm Red Rubber/Screw Cap Assembly (Pkg/100) 11 mm Crimp Cap Silver w/ Red Rubber/PTFE Septa (Pkg/100) 1 1 1 N9300699 N9306200 N9306201 9 mm PTFE/Sil Screw Cap Convenience Kit – Pkg/100 9 mm PTFE/Sil Screw Cap Assembly (Pkg/100) 9 mm Clear 2 mL Vial Kit (Pkg/100) 1 1 1 N9300700 N9306202 N9306201 Order online at www.perkinelmer.com/supplies ORDER TODAY 41 elite columns Elite Series capillary columns use only the finest quality high-strength fused silica Top 10 reasons to buy PerkinElmer Elite Series Capillary Columns 1. Finest quality of high-strength fused silica 2. Each column individually inspected and tested Phase Cross Reference Chart Phase/Description Equivalent Capillary Phase Elite-1, Elite-1ht 100% Dimethyl DB-1, DB-1ht, HP-1, HP-101, Ultra-1, SPB-1, CP-Sil 5CB, CI-Sil5CBMS. RSL-150, RSL-160, Rtx-1, BP-1, CB-1, OV-1, 007-1MS, SP-2100, SE-30 3. Reproducible results 4. Crosslinked and bonded stationary phase Elite-200 Trifluoropropylmethyl DB-210, AT-210, VF-200MS, 007-210, Rtx-200 5. Robust column cage Elite-5, Elite 5ms, Elite -5ht DB-5, DB-5ms, DB-5ht, Ultra-2, SPB-5, CP-Sil8CB, 5% Diphenyl – 95% Dimethyl RSL-200. Rtx-5, BP-5, CB-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5. Rtx-5ms, PTE-5, HP-5ms 6. Superior resolution 7. Wide selection of stationary phases available 8. Reduced baseline bleed 9. Lower baseline noise 10. Column lengths from 5 to 105 M Why choose fused silica? Many factors influence the quality of a column. Fused silica is considered to be the purest form of glass, with fewer metal oxides (Lewis acid sites) and hydrogen bonding (surface silanol) groups. The stationary phase is cross linked (polymerized) and also bonded to the surface of the column to provide a high degree of stability, resulting in lower bleeding of the stationary phase at elevated temperatures. The superior inertness of the column means that acidic and basic compounds can be analyzed on the same column. Selecting the right Stationary Phase The inherent efficiency (large number of theoretical plates) of capillary columns allows you to choose from relatively few types of phases, compared to the many varieties of packed columns previously required. Perhaps more importantly, because capillary columns are more efficient, you will see superior resolution resulting in narrower, taller peaks that allow easier integration from your data system. Identification of small peaks are facilitated by a reduced baseline bleed and lower baseline noise. Non-polar Elite-1 columns from PerkinElmer will preferentially retain non-polar compounds, whereas the PerkinElmer Elite-200 column phase provides high selectivity for analytes containing lone pair electrons, such as nitro and carbonyl groups. Elite-WAX polyethylene glycol columns are highly selective toward polar compounds such as alcohols. What length do I need? Typically capillary columns are available in lengths from 15 to 105 meters. The longer the column the more resolving power, but this also increases the analysis time. Doubling a column length only increases resolution by approximately 40% but, under isothermal conditions, will double the analysis time. If using a temperature programmed analysis retention times are more dependent on the temperature than on the column length. PerkinElmer provides columns in the most popular lengths of 5, 10, 12, 15, 25, 30, 50, 60, 75, 100 and 105 meters depending upon the column i.d. 42 Elite-5Amine 5% Diphenyl – 95% Dimethyl Polysiloxane PTA-5 Elite-35, Elite-35ms 35% Phenyl – 65% Methyl DB-35, DB-35ms, Rtx-35, SPB-35, AT-35, Sup-Herb Elite-17, Elite-17ms, Elite-17ht DB-17, DB-17ht, HP-17, RSL-300, Rtx-50, 50% Phenyl – 50% Methyl 007-17(MPS-50), SP-2250, HP-50+ Elite-1301 6% Cyanopropylphenyl DB-1301, Rtx-1301, CP-624 Elite-1701 14% Cyanopropylphenyl – 86% Dimethyl DB-1701, SPB-7, CP-Sil 19CB, Rtx-1701,BP-10, CB-1701, OV-1701, 007-1701 Elite-225 50% Cyanopropylphenyl – 50% Phenyl methyl DB-225, HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, 007-225 Elite-WAX Polyethylene Glycol DB-FFAP, HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, Elite-CW 007-CW, Carbowax, HP-Innowax Elite-FFAP Polyethylene Glycol – Acid Modified DB-WAX, HP-FFAP, Nukol, SUPEROX FA, STABILWAX-DA, 007-FFAP, OV-351, DB-FFAP Elite-608 Specialty phase for semivolatile pesticides (EPA 608) SPB-608, NON_PAKD Pesticide, DB-608, 007-608, HP-608 Elite-624, Elite-Volatiles Specialty phase for volatiles DB-624, DB_VRX, VOCOL, NONPAKD AT-624, Rtx-Volatiles, Rtx-502.2, 007-624, HP-624, CP-624, Rtx-624 Elite-CLPesticides Specialty Phase for Chlorinated Pesticides Rtx-CLPesticides Elite-VMS Specialty Phase for Volatile Organics on GC/MS Rtx-VMS Elite-PONA DB-Petro100, Petrocol DH, HP-PONA, Dimethyl polysiloxane SPB-1, 007-1, RTx-1PONA processed for the detailed analysis of petroleum naphtha See page 2 for ordering information and a complete listing of PerkinElmer offices. Elite-1 Dimethylpolysiloxane 100% Dimethyl Polysiloxane phase: The 100% Dimethyl Polysiloxane is a highly versatile phase that is extremely rugged, exhibiting long column lifetime, low bleed, and high maximum operating temperatures. Primary Applications Elite columns are ideal for the analysis of non-polar petrochemical samples, such as detailed hydrocarbon analysis, hydrocarbon gases, petroleum oxygenates, petroleum aromatics, fuels, waxes, oils, sulfur compounds, mercaptans, and carbon disulfide. It also is an excellent phase for solvents, chemicals, flavors, fragrances, essential oils, air toxins, chlorofluorocarbons, arson analysis, pesticides, hydrocarbons and high-temperature applications. Features and Benefits ■ Thermal stability to 350 °C ■ Low Bleed ■ Low baseline noise Description Dimensions ELITE-1 30 M x 0.25 mm x 0.25 μm ELITE-1 30 M x 0.32 mm x 0.25 μm ELITE-1 60 M x 0.25 mm x 0.25 μm ELITE-1 30 M x 0.32 mm x 1.00 μm ELITE-1 60 M x 0.32 mm x 1.00 μm For our complete selection of columns please visit our web site at www.perkinelmer.com/gcsupplies Part No. N9316010 N9316023 N9316013 N9316024 N9316029 Elite-CLPesticides Elite-CLPesticides is specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide analyses for U.S. EPA methods 8081, 608 and CLP. Column bleed measured by ECD is extremely low at temperatures greater than 300 °C, which is critical for baking out the column to remove high-boiling compounds commonly found in pesticide/PCB extracts. elite columns Elite-1, Elite-200, Elite-5 Amine, and Elite-CLPesticides Primary Applications Chlorinated pesticides and herbicides. U.S. EPA Methods 504, 608, 619, 8081, 8151 and CLP. Features and Benefits ■ Thermally stable to 340 °C ■ Low column bleed — ideal for ECD or GC/MS analysis ■ Exceeds performance criteria for U.S. EPA Methods 8081, 608, CLP ■ Baseline separation in less than 15 minutes Description Dimensions Part No. Elite-CLPesticides Elite-CLPesticides Elite-CLPesticides Elite-CLPesticides Elite-CLPesticides Elite-CLPesticides 15 M x 0.25 mm x 0.25 μm 15 M x 0.53 mm x 0.50 μm 15 M x 0.25 mm x 0.20 μm 30 M x 0.32 mm x 0.50 μm 30 M x 0.32 mm x 0.25 μm 30 M x 0.53 mm x 0.42 μm N9316661 N9316665 N9316667 N9316664 N9316670 N9316672 Elite-200 Trifluoropropylmethyl Polysiloxane Capillary Column Elite-5Amine 5% Diphenyl and 95% Dimethyl Polysiloxane The tubing surface of the Elite-5Amine is chemically altered to reduce tailing of basic compounds. Thorough testing on each column ensures that every column exceeds the requirements for analyzing ppm levels of amines, without priming. The temperature program/bleed profile is measured to ensure low bleed at maximum operating temperature. This column is ideal for analyzing a wide variety of basic compounds such as alkylamines, diamines, triamines, ethanoloamines nitrogen-containing heterocycles. Elite-200 is considered to be one of the best capillary columns in the market today, solving many difficult separation problems not possible on any other bonded stationary phase. Due to the electrophilic nature of the fluorine-containing polymer, Elite-200 trifluoropropyl stationary phase has a unique selectivity creating interactions with compounds that contain groups displaying lone-pair electrons, or with electron-rich molecules. Primary Applications Ideal for solvents, Freon®, fluorocarbons, alcohols, ketones, silanes and glycols, environmental analytes and CFCs. Primary Applications Specifically designed for amines and other basic compounds. Features and Benefits Features and Benefits ■ Low bleed ■ Superior inertness ■ Thermally stable to 315 °C ■ Equivalent to USP G6 phase ■ Reduced tailing ■ Thermally stable to 340 °C ■ Low bleed at maximum operating temperature ■ Eliminates column priming Description Dimensions Part No. Elite-5Amine Elite-5Amine Elite-5Amine Elite-5Amine Elite-5Amine 15 M x 0.32 mm x 1.00 μm 15 M x 0.53 mm x 3.00 μm 30 M x 0.25 mm x 0.50 μm 30 M x 0.25 mm x 1.00 μm 30 M x 0.32 mm x 1.50 μm N9316676 N9316681 N9316673 N9316675 N9316679 Description Dimensions Part No. Elite-200 Elite-200 Elite-200 Elite-200 Elite-200 Elite-200 15 M x 0.25 mm x 0.10 μm 15 M x 0.32 mm x 1.50 μm 30 M x 0.25 mm x 0.25 μm 30 M x 0.53 mm x 1.00 μm 60 M x 0.53 mm x 0.25 μm 60 M x 0.53 mm x 1.00 μm N9316616 N9316632 N9316619 N9316642 N9316637 N9316643 Order online at www.perkinelmer.com/supplies ORDER TODAY 43 elite columns Elite-Guard and EliteSiltek® guard columns Velocity Series Capillary Columns Maintain the integrity of your capillary column with a fused silica guard column Velocity-1, Velocity-5, and Velocity-Wax Using the Elite-Guard or Elite-Siltek® guard column lengthens the life of the capillary column and improves the analyte focusing. The 5 M length of deactivated uncoated fused silica is connected to the inlet end of the capillary column and traps nonvolatile residues, preventing them from collecting at the head of the analytical column. This length of fused silica does not contain stationary phase adding only a minimal amount of time to the analysis. PerkinElmer offers both the intermediate-polarity deactivated guard column and the Siltek® deactivated guard column as it is important to match the polarity of the solvent and the polarity of the surface deactivation. Elite-Guard intermediate-polarity deactivated column has an operating temperature up to 325 °C. Siltek® deactivation creates a highly inert surface for very active compounds such as chlorinated pesticides with a maximum temperature range up to 380 °C. Features and Benefits ■ ■ ■ Increase column life and performance Elite-Guard temperature range to 325 °C Elite-Siltek® guard temperature range to 380 °C Description Dimensions Part No. Elite-Guard Elite-Guard Elite-Guard Elite-Guard Elite-Guard Elite-Guard Elite-Siltek® Guard Elite-Siltek® Guard Elite-Siltek® Guard 5 M x 0.10 mm 5 M x 0.18 mm 5 M x 0.25 mm 5 M x 0.32 mm 5 M x 0.45 mm 5 M x 0.53 mm 5 M x 0.25 mm 5 M x 0.32 mm 5 M x 0.53 mm N9316601 N9316602 N9301356 N9301357 N9316605 N9301358 N9316607 N9316608 N9316609 Perkin-Elmer Velocity columns are excellent for standard daily test applications. They combine quality and affordability with reproducible results. Features and Benefits ■ ■ ■ Excellent results for theoretical plates, selectivity, & tailing factor tests Robust column cage Low baseline noise Velocity-1 — 100% Dimethyl Polysiloxane General purpose columns with a highly versatile phase that is extremely rugged, exhibiting long column lifetime, and high operating temperatures. Ideal for the analysis of non-polar petrochemical samples, such as detailed hydrocarbon analysis, hydrocarbon gases, petroleum oxygenates, petroleum aromatics, fuels, waxes, oils, sulfur compounds, mercaptans, and carbon disulfide. It also is an excellent phase for solvents, chemicals, flavors, fragrances, essential oils, air toxins, chlorofluorocarbons, arson analysis, pesticides, and hydrocarbons. Thermal stability to 350 °C. Description Dimensions Part No. Velocity-1 Velocity-1 Velocity-1 Velocity-1 Velocity-1 Velocity-1 Velocity-1 Velocity-1 Velocity-1 Velocity-1 15 M x 0.25 mm x 0.25 μm 15 M x 0.25 mm x 1.00 μm 30 M x 0.25 mm x 0.25 μm 30 M x 0.25 mm x 1.00 μm 30 M x 0.32 mm x 0.25 μm 30 M x 0.32 mm x 1.00 μm 30 M x 0.32 mm x 3.00 μm 60 M x 0.25 mm x 0.25 μm 60 M x 0.25 mm x 1.00 μm 60 M x 0.32 mm x 1.00 μm N9306319 N9306310 N9306312 N9306323 N9306318 N9306321 N9306329 N9306320 N9306328 N9306324 Velocity-5 — 5% Diphenyl and 95% Dimenthyl Polysiloxane This column is ideal for general purpose analyze of drugs, pesticides, hydrocarbons, essential oils and semi-volatiles and solvent impurities. Low polarity phase with thermal stability to 350 °C. Wide-Bore Adapter Kit Contains all the parts necessary to adapt packed column injectors quickly and easily for use with wide-bore capillary columns. Includes 0-20 mL/min flow controller element, wide-bore adapter with 1⁄16 inch fitting, wide-bore glass liner and column support hanger. Description Part No. Wide-Bore Adapter Kit N6120001 Universal Connectors 44 ■ Allows for fast, leak-free connections of fused-silica columns ■ The new fused-silica tapered design allows connection of any size column and is easy to use. (Suitable for 0.1 to 0.53 mm columns) Description Part No. Universal Connector (pkg. 5) Universal Y Splitter (pkg. 1) Polyimide Sealing Resin (5 g) Undeactivated Presstight Column Connectors (pkg. 5) N9302149 N9303448 N9301343 N9303962 Description Dimensions Part No. Velocity-5 Velocity-5 Velocity-5 Velocity-5 Velocity-5 Velocity-5 15 M x 0.32 mm x 0.25 μm 30 M x 0.25 mm x 0.25 μm 30 M x 0.32 mm x 0.25 μm 30 M x 0.32 mm x 1.00 μm 30 M x 0.53 mm x 0.50 μm 30 M x 0.53 mm x 1.50 μm N9306325 N9306311 N9306313 N9306316 N9306326 N9306327 Velocity-Wax — Polyethylene Glycol This column is ideal for intermediate to high polarity compounds. Thermal stability to 250 °C. Description Dimensions Part No. Velocity-Wax Velocity-Wax Velocity-Wax Velocity-Wax 30 M x 0.32 mm x 0.25 μm 30 M x 0.25 mm x 0.25 μm 30 M x 0.32 mm x 0.50 μm 30 M x 0.53 mm x 1.00 μm N9306314 N9306315 N9306317 N9306322 Wafer Scribes The PerkinElmer ceramic wafer scribe is inexpensive and ideal for cutting polyimide fused silica capillary columns and guard columns. The scribe is easy to hold and simple to use. All four sides can be used as a cutting tool. (pkg. 10) Description Part No. Wafer Scribes (pkg. 10) N9301376 See page 2 for ordering information and a complete listing of PerkinElmer offices. NEW from PerkinElmer! Complete Consumable Application Kits All your consumable needs in one convenient kit, designed specifically to be used within the application requirements for OVI, Environmental, Blood Alcohol and Biodiesel Materials Testing application notes*. Environmental Application Kit for U.S. EPA Method 8260B Part No. Promo Code: GC020804 (see details below) Contents: Biodiesel Application Kit ASTM 6584 Part No. N9300670 Contents: Autosampler Syringe 5.0 μL (0.47 mm) Elite-5ht Column 15 M x 0.32 mm x .10 μm Elite Guard Column (ht) 5 M x 0.53 mm Mini Union Connector Kit – Includes Mini Union and Nuts, 0.32 mm Ferrules and 0.53 mm Ferrules 11 mm Electronic Crimper Crimp Vials 2 mL Aluminum Crimp Caps 11 mm Rubber/PTFE GC Septa Injector Liner, Hour Glass Pkg. Qty. 1 1 1 5 2 1 1 1 N6101380 N9316274 N9316609 N9306128 Part No. 1 100 100 50 1 1 5 5 1 2 N9302592 N9301385 N9306015 N6621028 N6101703 Part No. N9300672 Contents: Pkg. Autosampler Syringe 5.0 μL (0.47 mm) Elite-5ht Column 15 M x 0.32 mm x 0.10 μm Elite Guard Column (ht) 5 M x 0.53 mm Mini Union Connector Kit – Includes Mini Union and Nuts, 0.32 mm Ferrules and 0.53 mm Ferrules Elite-MXT2887 SIMDIS Column 20 mm Electronic Crimper Crimp Vials 2 mL Aluminum Crimp Caps 11 mm Rubber/PTFE GC Septa Injector Liner, Hour Glass Graphite Ferrules Qty. Part No. 1 1 1 5 2 1 1 1 N6101380 N9316274 N9316609 N9306128 1 1 100 100 50 1 10 1 1 5 5 1 2 1 N9316689 N9302594 N9301385 N9306015 N6621028 N6101703 09903394 Blood Alcohol Application Kit Part No. Promo Code: GC020802 (see details right) Contents: Pkg. Qty. Part No. 1 1 1 1 1 1 B0104236 B4000022 N9302571 N9302594 09936885 N9301357 1 1 N9316388 N9302149 OVI (Organic Volatile Impurities) Application Kit for Pharmaceuticals Part No. Promo Code: GC020801 (see details below) N9300655 Pkg. Elite-130 / 130 m x 0.53 mm x 3.0 μm Zero Dilution Glass Outer Liner Zero Dilution Glass Inner Liner Polyimide Uncoated Deactivated Tubing / 5 m x 0.18 mm 20 mm Headspace Crimp Vials Assembled Headspace Caps and Septa 20 mm Electronic Crimper Application Notes NEW! 1,000 1,000 Qty. Part No. 1 1 1 1 N9316687 N1011445 N1011446 N9301354 1 1 1 1 B0104236 B4000022 N9302594 09936887 Materials Testing or Food and Beverage GC/Headspace Consumables Kit Part No. Promo Code: GC020803 (see details below) Contents: N9300657 Pkg. 20 mm Headspace Crimp Vials Assembled Headspace Caps and Septa 20 mm Electronic Crimper Application Notes NEW! 1,000 1,000 Qty. 1 1 1 1 Part No. B0104236 N1010070 N9302594 09936888 N9300656 Pkg. 20 mm Headspace Crimp Vials 19 mm PTFE/Butyl Caps, Springs & Septa 20 mm Electronic Crimper Application Notes NEW! Elite-BAC-1 / 30 m x 0.32 mm x 1.8 μm Elite-BAC-2 / 30 m x 0.32 mm x 1.2 μm 1 ⁄16" to 0.5 mm 2-hole Graphite Ferrule N9300658 20 mm Headspace Crimp Vials 1,000 19 mm PTFE-Coated/Silicone Caps, Springs & Septa 1,000 20 mm Electronic Crimper, 110 V 20 mm Electronic Crimper Application Notes NEW! Polyimide Deactivated Uncoated Tubing / 5 m x 0.32 mm Elite-Volatiles / 30 m x 0.25 mm x 1.4 μm Universal Connector 5 Contents: Biodiesel Application Kit ASTM 6584 & D2887 SIMDIS2 application kits Convenient Consumable Kits for a Variety of Applications 1,000 1,000 5 Qty. 1 1 1 1 1 1 1 Part No. B0104236 N1010070 N9302594 09936886 N9316579 N9316577 N9306001 Save on your next Application Kits Consult your Authorized PERKINELMER Sales Office for special promotions. * For full downloadable pdf format application notes, please visit: http://las.perkinelmer.com/applications Order online at www.perkinelmer.com/supplies ORDER TODAY 45 headspace and headspace trap accessories For TurboMatrix Headspace and Headspace Trap Sample Trays For use on the Mid-Range or High-Capacity headspace sampler. Description Part No. TurboMatrix 40 Mid-Range Sample Tray TurboMatrix 110 High-Capacity Sample Tray M0413592 M0413593 Transfer Lines Description Siltek Deactivated Fused-Silica Siltek Deactivated Fused-Silica Tubing i.d. Length 0.25 mm 0.32 mm 5m 5m N9316607 N9316608 Miscellaneous Accessories TurboMatrix 40 Headspace Trap Description Part No. Gas Chromatography – Theory and Practice, Static Headspace Book by L. Ettre and B. Kolb N1011210 Cold Trap Options Headspace Trap instruments only. Sample Head Assembly Replacement Parts Description Part No. Platinum/Iridium Needle, Wide-Bore Platinum/Iridium Needle, Small-Bore Platinum/Iridium Needle, Jet Silcosteel Needle, for Headspace Trap Only Stainless Steel Needle, Wide-Bore Stainless Steel Needle, Small-Bore Stainless Steel Needle, Jet (ships with instrument) B0144169 B0500959 B0510364 N6700130 B0131385 B0500987 B4000011 2 Needle Seal Assembly (without O-Rings) B0500833 3 O-Ring for Needle Seal Assembly (pkg. 10) B0198110 4 Vespel Ferrule 1⁄16 in. (pkg. 10) 09920127 5 Male Nut 1⁄16 in. N9302832 6 GLT Adapter Tube GLT Adapter Tube, Silcosteel B0503956 N6700113 7 Graphite/Vespel Ferrule 1⁄16 in. x 0.4 mm For use with 0.25 mm i.d. Transfer Line, pkg. 10 Graphite/Vespel Ferrule 1⁄16 in. x 0.5 mm For use with 0.32 mm i.d. Transfer Line, pkg. 10 09920104 8 Nut 1⁄16 in. Swagelok N9300059 9 Fused-Silica Capillary Transfer Line: 0.25 mm i.d. x 5 m length 0.32 mm i.d. x 5 m length N9301356 N9301357 1 Description Part No. TurboMatrix HS Trap Cold Trap Tube (Carbopack C) TurboMatrix HS Trap Air Monitoring Trap* N6200150 M0413628 *Trap comes standard with the instrument. Headspace Sample Head Assembly Schematic 09903700 1 9 8 7 6 Solid Glass Blocking Trap 46 Part No. 5 4 2 Description Part No. Block for use in standard headspace mode. N6701170 3 2 3 See page 2 for ordering information and a complete listing of PerkinElmer offices. headspace vials/caps Headspace Vials, Caps, and Septa Kits from PerkinElmer One-step solution – from field sample to lab results PerkinElmer offers a variety of GC headspace vials, caps and septa to fulfill your application needs. Our patented vial and cap design incorporates pressure-relief features which guarantee safe operation with the high pressure typically developed during thermostatting. Ordinary vials and caps without these safety features may burst. All of our headspace vials are 20 mL, providing a maximum liquid sample volume of 15 mL. They have a greater wall thickness and round base which enables them to withstand pressure up to 60 psig. Low-volume sampling can be achieved by using a 6 mL crimp vial and vial adapter. All PerkinElmer headspace vials are manufactured to specific tolerances that are guaranteed to fit within PerkinElmer instruments. Headspace Vials with Write-on Patch and Fill Lines Features and Benefits ■ Patented vial and cap design guarantees safe operation ■ Manufactured to specific tolerances guaranteed to fit PerkinElmer instruments ■ Lot-tested, certified and approved septa deliver reproducible results Headspace Screw Top Vials and Preassembled Caps NEW from PerkinElmer, headspace screw top vials and preassembled caps allow for samples to be taken in the field and directly analyzed on the PerkinElmer® TurboMatrix™ Headspace Sampler* without having to transfer the sample into another vial, streamlining the sampling process and increasing your productivity. Screw thread vials are designed for a guaranteed fit. PerkinElmer septa are lot tested for impurities. The cap is conveniently preassembled for ease-of-use and packed in clean Mylar® bags to reduce the risk of contamination. Description Pkg Part No. 20 mL Headspace Screw Top Vials 20 mL Headspace Screw Top Vials 18 mm PTFE/Butyl Assembled Caps/Septa 3.2 mm thickness 18 mm PTFE/Silicone Assembled Caps/ Septa 3.2 mm thickness 18 mm Red PTFE/White Silicone metal Screw Cap/ Septa 1.3 mm thickness 8 mm hole 18 mm White PTFE/Transparent Blue Silicone metal Screw Cap/Septa 1.3 mm thickness 8 mm hole 18 mm Blue PTFE/White Silicone metal Screw Cap/ Septa 1.5 mm thickness 8 mm hole 18 mm Gray PTFE/Red Butyl metal Screw Cap/ Septa 1.6 mm thickness 8 mm hole 100 1000 100 100 N9306075 N9306078 N9306076 N9306077 100 N6356474 100 N6356475 100 N6356476 100 N6356477 Vial Rack Holder: Description Pkg Part No. 36-Vial Polypropylene 20 mm Holder 1 N9301304 Description Pkg Part No. 20 mL Headspace Crimp Top Vials with Write-On White Patch and Fill Lines 20 mL Headspace Crimp Top Vials with Write-On White Patch and Fill Lines 20 mL Headspace Screw Top Vials with Write-On White Patch and Fill Lines 20 mL Headspace Screw Top Vials with Write-On White Patch and Fill Lines 10 mL Clear Crimp Top Headspace Vials 10 mL Clear Screw Top Headspace Vials 20 mL Clear Crimp Top CTC Headspace Vials 1000 N9303348 100 N9303349 1000 N9306241 100 N9306240 100 100 100 N6356478 N6356479 N6356471 Headspace Crimp-top Vials and Preassembled Caps Description Pkg Part No. 6 mL Headspace Clear Glass Vial* ** Low-Volume Vial Adapter 20 mL Headspace Clear Glass Vial 20 mL Headspace Crimp Top Vials 20 mL Headspace Crimp Top Vials with Write-On White Patch and Fill Lines 20 mL Headspace Crimp Top Vials with Write-On White Patch and Fill Lines Red Butyl Rubber Septa/Cap/Spring Red Butyl Rubber Septa/Cap/Spring Red Butyl Rubber Preassembled Red PTFE-Coated Butyl Rubber/Cap/Spring 125 10 1000 100 1000 N9302134 N6120110 B0104236 N9306079 N9303348 100 N9303349 100 1000 1000 100 B0159356 B0159357 N1010070 B0104239 *Not compatible with TurboMatrix HS 110 headspace sampler **Use with Low-Volume Vial Adapter (N6120110) Order online at www.perkinelmer.com/supplies ORDER TODAY 47 headspace and crimp-top caps and septa Headspace Crimp-top Caps and Septa Crimp Top Cap and Septa – GC Headspace (CTC Autosampler) Description Pkg Part No. 20 mm magnetic cap/septa 8 mm hole w/3.2 mm thickness Silicone/PTFE Transparent White liner 20 mm magnetic cap/septa 8 mm hole w/3.0 mm thickness Silicone/PTFE Transparent Blue liner 20 mm magnetic cap/septa 8 mm hole w/3.0 mm thickness PTFE/Butyl gray 20 mm magnetic cap/septa 8 mm hole w/3.0 mm thickness Gray Butyl liner 20 mm magnetic cap/septa 8 mm hole w/3.0 mm thickness Pharma fix Butyl/PTFE 20 mm magnetic cap/septa 8 mm hole w/3.2 m thickness Aluminum/Silicone liner 20 mm magnetic cap/septa 8 mm hole w/1.3 mm thickness Silicone/PTFE Trans Blue (SPME liner) 20 mm magnetic bi-metal cap/septa w/3.0 mm 8 mm thickness PTFE/Blue liner 20 mm bi-metal cap/septa w/3.0 mm Silicone 8 mm thick PTFE Transparent Blue liner 100 N6356558 100 N6356559 100 N6356560 100 N6356561 100 N6356562 100 N6356563 100 N6356564 100 N6356565 100 N6356566 Headspace Crimp-top Septa and Pre-assembled Caps Description Pkg Part No. Red PTFE-Coated Butyl Rubber/Cap/Spring Red PTFE-Coated Butyl Rubber Preassembled Aluminum-Coated Silicone/Cap/Spring Aluminum-Coated Silicone/Cap/Spring Aluminum-Coated Silicone Preassembled PTFE-Coated Silicone/Cap/Spring PTFE-Coated Silicone/Cap/Spring PTFE-Coated Silicone Preassembled 20 mm Gray Butyl/PTFE pre-assembled cap/septa/spring 20 mm Gray Butyl/PTFE pre-assembled cap/septa/spring clear 20 mL headspace with write-on patch and fill lines Gray PTFE/Butyl Kit, unassembled cap/septa/spring Gray PTFE/Butyl Kit, unassembled cap/septa/spring 20 mm Gray Butyl pre-assembled cap/septa/spring 20 mm Butyl pre-assembled cap/septa/spring clear 20 mL headspace with write-on patch and fill lines Gray Butyl Kit unassembled cap/septa/spring Gray Butyl Kit unassembled cap/septa/spring 1000 1000 100 1000 1000 100 1000 1000 1000 100 B0104240 B4000025 B0104243 B0104244 B4000028 B0104241 B0104242 B4000022 N9306264 N9306265 100 1000 1000 100 N9306266 N9306267 N9306268 N9306269 100 1000 N9306270 N9306271 Septa Recommended Temperatures Material Red Butyl Rubber Gray Butyl Rubber Gray PTFE-Coated Butyl Rubber Red PTFE-Coated Butyl Rubber Aluminum-Coated Silicone PTFE-Coated Silicone 48 Upper Temp Limit at Vial 100 ºC 130 ºC 130 ºC 100 ºC 210 ºC 220 ºC See page 2 for ordering information and a complete listing of PerkinElmer offices. Inertness Fair Fair Good Good Good Good Headspace Vial, Septa, and Cap Kits PerkinElmer understands your challenges and offers a variety of kits so that you can easily order and restock your laboratory supplies. headspace starter kits One-step solution – from field sample to lab results – NEW PerkinElmer Headspace Starter Kits Headspace Mini Starter Kit The same great consumables as the Headspace Starter Kit (N6710195) without the “Static Headspace Gas Chromatography Theory and Practice” book, and with fewer vials – 200 total (100 each crimp and screw top vials). Part No. Headspace Mini Starter Kit: N6710197 Contents: Pkg. Qty. 20 mL Headspace Crimp Vials 20 mm PTFE/Butyl Septa/Cap/Springs 20 mm PTFE/Silicone Septa/Cap/Springs 20 mm Aluminum Silicone Septa/Cap/Springs O-Rings Needle Seal Assemblies Pressure Gauge with Needle for Vials 20 mm Hand Crimper 20 mL Headspace Screw Top Vials* 18 mm PTFE/Butyl Assembled Cap and Septa* 18 mm PTFE/Silicone Assembled Cap and Septa* 100 100 100 100 10 1 1 1 100 100 100 1 1 1 1 1 2 1 1 1 1 1 Part No. N9306079 B0104239 B0104241 B0104243 B0198110 B0500833 B0501377 N9302785 N9306075 N9306076 N9306077 *Not compatible with TurboMatrix HS 110 headspace sampler Headspace Starter Kit Offers a variety of headspace consumables so you can evaluate different types of septa and vials for your sampling requirements. Part No. TurboMatrix™ Headspace Starter Kit: N6710195 Contents: Pkg. Qty. Part No. 20 mL Headspace Crimp Vials 20 mm PTFE/Butyl Septa/Cap/Springs 20 mm PTFE/Silicone Septa/Cap/Springs 20 mm Aluminum Silicone Septa/Cap/Springs O-Rings Needle Seal Assemblies Pressure Gauge with Needle for Vials “Static Headspace Gas Chromatography Theory and Practice” Book by B. Kolb and L.S. Ettre 20 mm Hand Crimper 20 mL Headspace Screw Top Vials* 18 mm PTFE/Butyl Assembled Cap and Septa* 18 mm PTFE/Silicone Assembled Cap and Septa* 100 100 100 100 10 10 1 1 1 100 100 100 5 1 1 1 1 2 1 1 1 5 1 1 N9306079 B0104239 B0104241 B0104243 B0198110 B0500833 B0501377 N1011210 N9302785 N9306075 N9306076 N9306077 *Not compatible with TurboMatrix HS 110 headspace sampler Order online at www.perkinelmer.com/supplies ORDER TODAY 49 headspace convenience kits Headspace Convenience and Stopper Kits Headspace Cap and Stopper Kits Description Pkg. Butyl Rubber Stoppers with Caps Butyl Rubber Stopper Knurled Caps PTFE/Silicone Injector Septa Injection-Septa 1000 100 100 12 12 Qty. 10 10 1 Part No. B0110728 B0038137 B0099814 00091357 00092388 Choosing the Right Septa for your Analysis Although a wide variety of septa is available, chemical compatibility and temperature are the most critical to the analysis. Temperature applies not only to the vial, but also to the temperature of the instrument’s needle used for pressurization and sample transfer, which is heated to prevent condensation. A needle temperature higher than the vial temperature setting can decompose the septum material. PTFE coated silicone and aluminum-coated silicone offer the highest temperature operating limits. (See Septa Recommended Temperature Chart page 48.) Headspace Convenience Kits Description Pkg. Qty. 20 mL Butyl HS Convenience Kit 20 mm Red Butyl Assembly 20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap 100 100 100 1 1 N9303990 N1010070 N9303349 20 mL PTFE/Butyl HS Convenience Kit 20 mm Red PTFE/Butyl Assembly 20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap 100 100 100 1 1 N9303991 B4000025 N9303349 20 mL PTFE/Silicone Convenience Kit 20 mm PTFE/Silicone Assembly 20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap 100 100 100 1 1 N9303992 B4000022 N9303349 20 mL Al/Silicone Convenience Kit 20 mm Aluminum/Silicone Assembly 20 mL Crimp Clear Vial Kit with Write-On Patch 20 mm Cap 100 100 100 1 1 N9303993 B4000028 N9303349 SAVE - Volume discounts available on Vials, Caps, Septa and Convenience kits. Contact Your Area PerkinElmer Sales Office for details and promotions. 50 See page 2 for ordering information and a complete listing of PerkinElmer offices. Part No. crimping tools Crimping Tools Electronic Handheld and Benchtop Crimpers Crimping Tools Whatever your need may be, PerkinElmer offers a wide range of crimping tools for your convenience. Our universal voltage,precision control, power crimpers with adjustable settings are designed to deliver hundreds of crimps on a single battery charge. Electronic Crimpers: Description Pkg. 20 mm Electronic Universal Crimper with Global Mains Plug Pack 20 mm Electronic Universal Decapper with Global Mains Plug Pack 11 mm Electronic Universal Crimper with Global Mains Plug Pack 11 mm Electronic Universal Decapper with Global Mains Plug Pack Electronic Crimper Battery Rechargeable Battery 1 1 1 1 1 1 Part No. N9302594 N9302595 N9302592 N9302593 N9302585 N9302596 Electronic Crimpers Features and Benefits ■ Universal voltage ■ Precision control crimping ■ Ergonomically-designed grip ■ Numerous reproducible crimps from a single charge ■ Includes standard Black & Decker® VersaPak® Gold battery and charger ■ Fully rechargeable Hand Held and Bench-top Crimpers: Description 8 mm Hand Crimper 11 mm Hand Crimper 11 mm Hand Decapper 20 mm Hand Crimper 20 mm Hand Decapper Bench-top Vial Crimper 11 mm Crimper Jaws 20 mm Crimper Jaws Pkg. Part No. 1 1 1 1 1 1 1 1 N9306127 00090699 N9301390 N9302785 N9301270 N6621006 N6621008 N6621009 For more details, call your local representative or visit: www.perkinelmer.com/gcsupplies Order online at www.perkinelmer.com/supplies ORDER TODAY 51 thermal desorption Packed traps specifically designed for PerkinElmer Thermal Desorbers Air Monitoring Trap Low flow trap packed with carbonaceous sorbents suitable for ozone precursor and air toxics monitoring. Cold Traps Cold Traps Fittings and Accessories TurboMatrix Thermal Desorption Trap Supplies Trap supplies from PerkinElmer, the market leader in thermal desorption, will provide exceptional analytical performance. Used for U.S. EPA Method TO17, the PerkinElmer standard trap, packed with Tenax™, on the TurboMatrix™ Thermal Desorber, will improve productivity and trapping capacity. The TurboMatrix air monitoring trap is packed with carbonaceous sorbents suitable for ozone precursor and air toxics monitoring. Description Cold Traps for TurboMatrix Air Monitoring Trap Empty Trap Tenax™ TA 60/80 Packed Trap Carbopack® C Packed Trap Cold Traps for ATD 400 Air Monitoring Trap Trap Nuts (2 required) Trap Tube Low Flow, Empty (Narrow-bore at one end. Allows minimum gas flow during trap desorption) Tenax™ TA 60/80 Packed Trap Empty Trap 52 Qty. Part No. 1 1 1 1 M0413628 M0413627 M0413535 N6200150 1 1 1 L4275108 L4275009 L4275107 1 1 L4275089 L4271106 Description Qty. Graphite Ferrule 2 SilTite™ Ferrule (GC/MS) 0.4 mm 10 SilTite™ Ferrule (GC/MS) 0.5 mm 10 10 SilTite™ Ferrule (GC/MS) 0.8 mm SilTite™ Nuts 5 PTFE Ferrule 10 5 Graphite/Vespel® Ferrule for ATD 400 Valco® Graphite/Vespel® Ferrule for ATD 400 5 Trap Filter Disk Trap Packing Disk 20 Trap Packing Retaining Spring 5 Quartz Wool (untreated) 5g Cold Trap Packing Tool Cold Trap Removal Tool Regulator 0 – 60 psig Backflush Nozzle for ATD 400 Internal Standard Injection Accessory for ATD 400 Liquid Nitrogen Accessory for ATD 400 Gauze Loading Rig Replacement Plastic Plunger for Gauze Loading Rig See page 2 for ordering information and a complete listing of PerkinElmer offices. Part No. L4271187 N9306093 N9306094 N9306095 N9306096 L4275110 L1003027 L1003028 L1003030 L4271290 N6301054 N6102354 L4271203 L4271205 N6101474 L4275072 L4270010 L4270009 L4070023 L4071151 thermal desorption Packing material tube identification and polarity now on every tube! SVI™ Soil Vapor Intrusion™ Tubes Unconditioned Thermal Desorber Tubes Soil vapor intrusion occurs when toxic compounds that are present in the air space in soil of a contaminated location have ways of entering a building, potentially creating a health risk. Our new multi-bed construction extends the hydrocarbon range past naphthalene while retaining the lighter components, enabling larger sample volumes, hence, enhancing detection limits. Unique design that meets the challenges and criteria of the EPA regulations for air monitoring. Fully conditioned Thermal Desorber tubes shown Unconditioned Thermal Desorber Tubes ■ Enhanced recoveries, even of highly contaminated sites For your convenience, new low-cost thermal desorber tubes are offered in both stainless steel and glass. Each tube maintains its unique serial number which is etched for easy identification. Tubes are offered with a variety of sorbent packing materials for many GC applications including indoor and outdoor air monitoring, analysis of flavors and fragrances and the analysis of outgassing from packaging, polymers, pharmaceuticals and semi-conductor material. These tubes are unconditioned and ship with plastic end caps for short-term storage. ■ From chloromethane through diesel range hydrocarbons ■ After the analysis, tubes are clean and ready for re-sampling reducing costs Packed Unconditioned Sample Tubes, Plastic End Caps (pkg. 10) Sorbent Air Toxics Carbopack® B60/80 Carbosieve® SIII 60/80 Tenax™ GR 60/80 Tenax™ TA 60/80 Chromasorb™ 60/80 Carbopack® B 60/80 Carbopack® C 60/80 Carbosieve® SIII 60/80 Carbotrap® C/B NIOSH Stainless Steel Part No. Glass Part No. N9307050 N9307051 N9307052 N9307053 N9307054 N9307055 N9307056 N9307058 N9307059 N9307060 N9307061 N9307062 N9307063 N9307064 N9307057 N9307065 N9307066 Empty Sample Tubes without Caps Description Stainless Steel TD tubes Conditioned Stainless Steel TD tubes Un-Conditioned Conditioned Thermal Desorber Tubes Stainless steel and glass sample tubes are available with a wide variety of packing materials from single to multi-bed. PerkinElmer Thermal Desorber tubes will now be printed with the packing material clearly identified on each tube. In addition an arrow will also be printed, which points to the end of the tube where sample is drawn from, and also indicates the end that desorb vapors will exit. Each tube is etched with a unique serial number for ease of traceability and adsorbent identification. Stainless steel tubes may also be fitted with clips that accept adhesive labels for identification. Packed tubes are shipped with long-term brass storage caps and all PerkinElmer thermal desorber tubes are thermally conditioned and tested for background and backpressure. Packed Conditioned Sample Tubes, Brass Long-Term Storage Caps (pkg. 10) “NOT for Analytical test applications”, USE N6200119 PTFE caps and O-ring. (pkg. 20) Sorbent Description Part No. Stainless Steel (pkg. 10) Glass (pkg. 10) Stainless Steel (pkg. 100) L4270128 L4071594 L4270129 Empty Sample Tubes with Caps Description Part No. Stainless Steel (pkg. 10) Glass Lined Stainless Steel (pkg. 10) Glass (pkg. 10) M0413595 M0413597 M0413598 Part No. N9306277 N9306278 Air Toxics Carbopack® B60/80 Carbosieve® SIII 60/80 Tenax™ GR 60/80 Tenax™ TA 60/80 Chromasorb™ 60/80 Carbopack® B 60/80 Carbopack® C 60/80 Carbosieve® SIII 60/80 Carbotrap® C/B NIOSH 2549 Order online at www.perkinelmer.com/supplies Stainless Steel Part No. Glass Part No. N9307001 N9307002 N9307003 N9307004 N9307005 N9307006 N9307000 N9307008 N9307009 N9307010 N9307011 N9307012 N9307013 N9307007 N9307026 N9307038 N9307037 ORDER TODAY 53 thermal desorption Thermal Desorber kits and accessories from PerkinElmer Thermal Desorber Industrial Hygiene Application Kit All your consumable needs in one convenient kit, designed specifically for Industrial Hygiene using Thermal Desorption*. Workplace Air Monitoring Industrial Hygiene Application Kit** Thermal Desorber Starter Kit PerkinElmer’s convenient starter kit includes all products you need to run the TurboMatrix Thermal Desorber. Features and Benefits ■ All items available under one part number in a convenient kit ■ Guaranteed PerkinElmer parts ■ Improved chromatography with exceptional analytical performance using PerkinElmer parts Part No. M0413541 Contents: Glass Fiber Separator Disks Glass Sample Tubes Glass Wool Graphite Ferrules O-Ring O-Ring, Viton Packing Gauze PTFE Filter Discs PTFE Filter Discs – Large Retaining Spring Sample Tube-5 mL Stainless Steel Retaining Spring Stainless Steel Sample Tubes – Capped Tenax TA 60/80, Mesh-15 g Trap Tube Nuts Trap Tubes Pkg. Qty. 6 10 1 2 1 1 100 10 10 50 1 2 10 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Part No. N6710188 Contents: Pkg. Cold Trap O-Ring, 0.145 i.d./0.070 w.d. Cold Trap Tube (Tenax TA) Empty Glass Sample Tubes – No caps Graphite Ferrule Pen Clips for Stainless Steel Sample Tubes PTFE Ferrule PTFE Filter Disk – Either side of the cold trap Tenax TA Stainless Steel Sample Tubes Qty. 1 1 10 2 10 10 10 10 1 1 1 1 1 1 1 1 09200091 L4275089 L4071594 L4271187 L4071029 L4275110 L1003030 N9307005 * For full downloadable pdf format application notes, please visit: http://las.perkinelmer.com/applications ** Applicable to TurboMatrix 100/150/300/350 and 650 only. Part No. L4271290 M0413598 54120790 L4271187 L1003006 L1003008 L4071034 L1003030 L1003029 L4071123 04970673 L6301054 M0413595 04978064 L4275009 M0410094 Consult your authorized PERKINELMER Sales Representative for tier volume Thermal Desorber Caps and Accessories Description Brass Long-Term Storage Caps Recommended for long-term storage, two required per tube. Also requires Teflon® Ferrule (L1003015). Combined Teflon® Ferrule For use with 1⁄4 in Brass Long-Term Storage Caps (09908851), two required per tube. Diffusion Caps – Standard For passive air sampling, to ensure correct diffusion path length. Diffusion Caps with Membrane As above, with silicone membrane inserted. Pen Clips For Stainless Steel Thermal Desorber Tubes. PFA Teflon® Ferrules For TurboMatrix Storage End Caps. TurboMatrix Analytical Caps PTFE caps with o-ring, required for use on the TurboMatrix instrument during analysis. Pkg. 09908851 5 L1003015 10 L4070207 10 L4070208 10 L4071029 20 M0413625 20 N6200119 Delivering enhanced VALUE and outstanding SAVINGS on the products you use most! Part No. 1 discounts and promotions. 54 Part No. For a full listing of thermal desorber kits and supplies please visit us at: www.perkinelmer.com/gcsupplies See page 2 for ordering information and a complete listing of PerkinElmer offices. thermal desorption Cost-effective, round-the-clock air monitoring The Model STS 25 sequential tube sampler is used for the continuous monitoring of atmospheric concentrations of volatile organic compounds. The unit is housed in a compact weatherproof box and allows the monitoring of indoor and outdoor atmospheres. This convenient portable unit designed for pumped air sampling of up to 24 tubes, offers cost-effective, round-the-clock monitoring for the workplace and ambient air. It can be operated by a 12 V battery or can connect to 120 V/24 V mains electricity, making it extremely versatile for use in the laboratory or in the field. The sampler includes cables with jack plug connectors (for use with the monitoring pump) and a set of diffusion limiting caps. Maintenance kit and accessories are also available. Features and Benefits ■ Portability – small, lightweight and compact ■ Variable sampling times – operator adjusted from minutes to hours ■ Sample integrity – diffusion limiting caps block the sample from contaminants ■ Sampling versatility – heaters are included to prevent condensation Description Part No. Model STS 25 Sequential Tube Sampler Model STS 25 Maintenance Kit Includes; Rotor Tube Seals (pkg. 50), Filter Disks (pkg. 25), Diffusion Limiting Caps (pkg. 5) and Rotor Seal (pkg. 10) 12 V Rechargeable Battery Air Monitoring Pump (120 V) Cable (for connecting STS 25 to a generic 12 V battery) Diffusion Limiting Caps (pkg. 5) Electrical Adapter Allows for direct connection to wall outlet 120 V/240 V. Also acts as a battery charger for 12 V battery. Rotor Filter Disk Viton O-Ring (pkg. 50) L4280001 N6609060 L4280002 L4271275 L4285007 L4285001 L4280003 L4281023 L4275033 Consumable Application Kits All your consumable needs in one convenient kit, designed specifically to be used within the application requirements for Air Monitoring and Ozone Precursor application notes*. Air Monitoring Application Kit Part No. N6710187 Contents: Pkg. Qty. Air Toxics Stainless Steel Thermal Desorber Tubes Air Monitoring Trap Methyl Silicone Column 100 m x 0.32 mm x 5 μm 10 1 1 1 1 1 Part No. N9307001 M0413628 N6300155 Ozone Precursor Application Kit Part No. N6710186 Contents: Alumina PLOT Column 50 m x 0.32 mm i.d. Air Monitoring Trap Methyl Silicone Column 50 m x 0.32 mm x 1.0 μm Pkg. Qty. 1 1 1 1 1 1 Part No. N6301107 M0413628 N6301108 Ozone Precursor Accessories Personal Monitoring Pump This compact and lightweight sampler combines convenience and useful functions for accurate sampling. The personal monitoring pump offers two modes of sampling which are easily activated by turning the selector dial located at the back of the sampler. Two low-flow modes of sampling allow constant flows from 5 – 200 cc/min, as well as constant pressure for multiple sorbent-tube sampling from 1 – 350 cc/min (combined flow rates). Description Part No. Personal Monitoring Pump 5 – 200 mL/min 110 V N6102351 Description: Part No. Alumina PLOTTM Column. 50 m x 0.32 mm i.d. Nafion Dryer Particulate Filter Kit Includes disposable filter and fittings. For use in the ozone precursor analyzer. Restrictor Tubing N6301107 04974414 N6300063 N9301355 * For full downloadable pdf format application notes, please visit: http://las.perkinelmer.com/applications Order online at www.perkinelmer.com/supplies ORDER TODAY 55 Hydrogen and Air Gas Generators New and Improved next generation Generators for your application needs No Maintenance Hydrogen Generators A Safe Source of Hydrogen Both the PGX-H2 and the No Maintenance Hydrogen Generators have an auto shutoff procedure that places the units in standby in the event of an internal error and selectable alarms allow the user to be informed whenever operating conditions vary from the set point. PGX-H 2 Hydrogen Generators Pure gas hydrogen generator employ the newest membrane technology available for the safe production of pure hydrogen gas. This patented design is ideal for operation with gas analyzers, as fuel gas for flame tools, or as a source for pure hydrogen in plasma chambers and other isolated environments. Electrolytic membrane technology is preferred over alternative hydrogen generating techniques because it is clean, requires less maintenance and there is no need to store chemicals to maintain operation. The generators offer silent operation and require only deionized or distilled water with no caustic solutions that can affect the purity of the hydrogen. Technical Specifications for PGX-H2 56 Electrolysis cell PEM Membrane type H2 purity 99.9999% Delivery pressure 100 psig – 7 barg (max) H2 flow rate Adjustable, according to model (100 – 160 – 250 – 300 – 500 – 600 mL/min) Safety Auto shut-off User interface Set points, system status Display 4 row x 34 character LCD, set points, status, alarms Indicator lights Power ON, System OK, System error Outputs RS232C, bi-directional Options Remote control Cascading via RS-485 of up to 32 units in parallel for models 250 and 500 only (patented feature) Description Part No. PGX-H2 100 mL/min of hydrogen PGX-H2 160 mL/min of hydrogen PGX-H2 250 mL/min of hydrogen PGX-H2 500 mL/min of hydrogen PGX-H2 Desiccant Cartridge, Fitting and Refill Kit PGX-H2 Desiccant Refill (sufficient for 3 cartridge refills) PGX-H2 Deionizer Bag N9306058 N9306059 N9306060 N9306061 N9306064 N9306065 N9307097 The No Maintenance (NM-H2) Hydrogen Pure Gas Generators employ the newest membrane technology available for electrolytic production of pure hydrogen gas, including exclusive no maintenance auto-drying technology. Technical Specifications for No Maintenance Electrolysis cell PEM Membrane type H2 purity 99.9999% Auto Drying System No maintenance of drying cartridges (exclusive system) Delivery pressure 155 psig – 10 barg (max.) H2 flow rate Adjustable, according to model (100 – 160 – 250 – 300 – 500 – 600 – 1000 mL/min) Safety Auto shut-off User interface Set points, system status Display 4 row x 34 character LCD, set points, status, alarms Indicator lights Power ON, System OK, System error Options Remote control Cascading via RS-485 of up to 32 units in parallel for models 250 and 500 only (patented feature) Description Part No. 100 mL/min of hydrogen 160 mL/min of hydrogen 250 mL/min of hydrogen 500 mL/min of hydrogen 1000 mL/min of hydrogen N9307070 N9307071 N9307072 N9307073 N9307074 Accessories Description Part No. Cable for Cascading I/O Board Remote control RS-232 (Includes converter, cables, software) Auto refill Deionizer LE bag Triangle deionizer LE bag N9307093* N9307094 N9307095* * Requires I/O Board See page 2 for ordering information and a complete listing of PerkinElmer offices. N9307096* N9307097 N9307098 Zero and Ultra Air Generators The Zero / Ultra Zero Air Generators produce laboratory grade purified air for FID (flame ionization detectors) and other detectors. Designed with safety and convenience in mind, this system will generate purified and hydrocarbon free air from an existing in-house oil-free compressed air supply, eliminating the need for inconvenient high-pressure gas cylinders. Eliminating gas cylinders reduces annual operating costs associated with materials, labor, and down-time. The Zero / Ultra Zero Air Generator series removes HC pollutants to less than 0.1 ppm, and all forms of particles. Operation of the generator requires low levels of electrical power consumption. This complete turnkey system is engineered with the highest quality components, is easy to install, and requires minimal annual maintenance. The Ultra Zero Air Generators will remove CO and HC pollutants to less than 0.1 ppm, and NOx contaminants to 1 ppm. Carbon dioxide is also removed to about 1 ppm levels. WALL MOUNTABLE Ultra Zero Air Generators Features and Benefits Specifications for Zero Air Part No. N9307075 N9307076 N9307077 N9307078 N9307079 ■ Flow rate: < 0.1 ppm HC; < 0.1 ppm CO; < 1 ppm NOx; < 5 ppm CO2 Outlet Zero Air 1500 mL/min 3000 mL/min 6000 mL/min 15000 mL/min 30000 mL/min ■ Produce laboratory-grade purified air for the most accurate and convenient calibration of testing equipment Maximum Continuous Output Flow Rate 1.5 L/min 3.0 L/min 6.0 L/min 15.0 L/min 30.0 L/min ■ Electrical Requirements 230/115 VAC 230/115 VAC 230/115 VAC 230/115 VAC 250 W max 250 W max 250 W max 480 W max 230/115 VAC 480 W max Designed with safety and convenience in mind, this system will generate purified air from an existing in-house oil-free compressed air supply, eliminating the need for inconvenient high-pressure gas cylinders ■ Temperature / Pressure Control Board N/A Included Eliminate gas cylinders reducing annual operating costs associated with materials, labor and downtime, and reduces risk of injury to workers ■ Will remove CO and HC pollutants to less than 0.1 ppm and NOx contaminants to 1 ppm. Carbon dioxide is also removed to about 1 ppm levels. Operation of the generator requires low levels of air consumption and electrical power ■ Fully supported by PerkinElmer Service Organization Included Included Included Description Part No. 1.5 L/min of air (without compressor) 3.0 L/min of air (without compressor) 6.0 L/min of air (without compressor) 15.0 L/min of air (without compressor) 30.0 L/min of air (without compressor) N9307075 N9307076 N9307077 N9307078 N9307079 Specifications for Zero and Ultra Zero Air Outlet Hydrocarbon Concentration Outlet Carbon Monoxide Concentration Outlet Particles < 0.5 Microns Removed Outlet Air Temperature Max Inlet Hydrocarbon Concentration Maximum Outlet Pressure Max Inlet Carbon Monoxide Concentration Max Inlet Temperature Inlet Pressure Range (regulated to 7 bar) Inlet Port Outlet Port < 0.1 ppm < 0.1 ppm 99.99% Ambient +15 °C 100 ppm 6.5 bar 50 ppm 40 °C 4.5 – 10 bar 1/4" NPT 1/8" NPT Specifications for Ultra Zero Air Part No. N9307081 N9307082 N9307083 N9307080 Outlet Ultra Zero Air 1500 mL/min 3000 mL/min 6000 mL/min 15000 mL/min Outlet Carbon Dioxide Concentration < 5 ppm < 10 ppm < 10 ppm < 10 ppm Outlet Nitrogen Oxides Concentration < 0.1 ppm < 1 ppm < 1 ppm < 1 ppm Outlet Dewpoint < -70 °C < -50 °C < -50 °C < -50 °C Electrical Requirements 230/115 VAC 270 W max 230/115 VAC 270 W max 230/115 VAC 270 W max 230/115 VAC 500 W max Description Part No. 1.5 L/min of air (without compressor) 3.0 L/min of air (without compressor) 6.0 L/min of air (without compressor) 15.0 L/min of air (without compressor) N9307081 N9307082 N9307083 N9307080 All models come WITHOUT a compressor. Oil Free Compressor Required. Order online at www.perkinelmer.com/supplies ORDER TODAY 57 GC Quiet Compressor/High Purity Brass Regulator PerkinElmer Ultra Quiet Compact Oil Free Compressor for GC Zero and Ultra Zero Air Generators PerkinElmer’s GC Quiet Compressor This industrial ultra quiet compact oil free 6 gallon compressor that can be utilized in the immediate laboratory area for the supply of clean air. High Purity Brass Regulators Key Benefits: PerkinElmer regulators are constructed of high-purity brass barstock and have stainless steel diaphragms and metal-tometal seals. They are suitable for use with high-purity (>99.995% pure) noncorrosive gases. Regulators terminate in a 1⁄4 in. NPT Swagelock fitting. ■ Barstock body construction ■ Stainless steel diaphrams ■ Metal-to-metal seals ■ Use with high-purity carrier gas Horse Power: 0.60 Power Requirements: 115V/220V/50 – 60Hz High-purity Brass Regulators (Dual Stage) Output: 2.5 CFM Key Benefits: ■ ■ Ultra quiet for use in the laboratory area Compact size and light weight ■ Commercial / Industrial grade ■ 1 Year warranty on workmanship ■ 5.0 micron pre-filter and regulator ■ Internally powder coated air tank to prevent rust ■ Max Pressure: 100 PSI CGA Fitting Delivery Pressure Use Delivery Pressure Range (psig) Cylinder Pressure Gauge Guage (psig) (psig) Part No. Max Pressure: 7 bar CGA-350 H2 and Ar/CH4 4 – 100 0 – 200 0 – 4000 09907128 Operating Pressure PSI: 80 – 100 CGA-580 He, Ar, N2 4 – 100 0 – 200 0 – 3000 09907127 Output: 67 L/Min Operating Pressure Bar: 6 – 7 Noise Level: 62 db/A High-purity Brass Regulators (Single Stage) Tank Size: 6.0 Gal. Tank Size Liter: 24 L Dimensions: 16 x 16 x 20 in. Weight: 54 lbs. Pressure switch for automatic operation Packed Dimensions: 19 x 18 x 23 Packed Weight: 58 lbs. Description Part No. 115V 220V 60Hz 220V 50H N9306291 N9306292 N9306293 Delivery Pressure Use CGA-350 CGA-350 CGA-590* CO,H2 and Ar/CH4 Mixes 4 – 100 CO, H2 10 – 200 Air 10 – 200 GC Startup Kit GC Startup Kit ⁄8" Tubing and Fitting for (3) Gases 1 Description ⁄8" Tubing x 50 foot coil Copper Special Cleaning 1 ⁄8" Compression Brass Tee Two Piece Ferrule Brass Tee 1⁄8" Com x 1⁄8" Comp x 1⁄4" fnpt Brass Adjustable Safety Relief Valve Brass 50 – 150 PSI 1 ⁄4" fnpt x 1⁄8" Comp Fitting Brass 1 ⁄8" Port Connector Brass 1 ⁄8" Ferrule Brass 1 ⁄8" Compression Brass Nut 1 ⁄8" Compression Brass Fitting Cap Tubing Cutter 1⁄8" Tubing Teflon Tape Cylinder Pressure Gauge Guage (psig) (psig) Part No. 0 – 150 0 – 400 0 – 400 00230091 00230253 00230090 0 – 4000 0 – 4000 0 – 4000 Part No. N9306304 Qty 1 3 3 3 3 3 3 3 3 1 1 GC Startup Kit GC Startup Kit 1⁄8" Tubing and Fitting With One Single Stage Regulator Part No. N9306305 Description Qty. ⁄8" Tubing x 50 foot coil Copper Special Cleaning 1 ⁄8" Compression Brass Tee Two Piece Ferrule Brass Tee 1⁄8" Com x 1⁄8" Comp x 1⁄4" fnpt Brass Adjustable Safety Relief Valve Brass 50 – 150 PSI 1 ⁄4" fnpt x 1⁄8" Comp Fitting Brass 1 ⁄8" Port Connector Brass 1 ⁄8" Ferrule Brass 1 ⁄8" Compression Brass Nut 1 ⁄8" Compression Brass Fitting Cap Tubing Cutter 1⁄8" Tubing Teflon Tape Single Stage Analytical 0 – 100 psig delivery, CGA 350 (H2,Carbon Monoxide, Ethylene) 1 1 Delivery Pressure Range (psig) CGA Fitting *Supplied with 590-580 Adapter. GC Startup Kit 58 High Purity Brass Regulators 1 GC Startup Kit 1⁄8" Tubing and Fitting With One Dual Stage Regulator Part No. N9306306 Description Qty. ⁄8" Tubing x 50 foot coil Copper Special Cleaning 1 ⁄8" Compression Brass Tee Two Piece Ferrule Brass Tee 1⁄8" Com x 1⁄8" Comp x 1⁄4" fnpt Brass Adjustable Safety Relief Valve Brass 50 – 150 PSI 1 ⁄4" fnpt x 1⁄8" Comp Fitting Brass 1 ⁄8" Port Connector Brass 1 ⁄8" Ferrule Brass 1 ⁄8" Compression Brass Nut 1 ⁄8" Compression Brass Fitting Cap Tubing Cutter 1⁄8" Tubing Teflon Tape Dual Stage Analytical 0 – 100 psig delivery, CGA 580 (N2, Argon, He) 1 3 3 3 3 3 3 3 3 1 1 1 See page 2 for ordering information and a complete listing of PerkinElmer offices. 1 3 3 3 3 3 3 3 3 1 1 1 service plans Dependable Service coverage to enhance your productivity and performance Maximize instrument performance and uptime From unplanned repair expenses to lost productivity, few events can be as disruptive as the failure of a key instrument. With a service and support plan from PerkinElmer, your lab will be protected from unplanned downtime and unexpected expense. Planning for future service needs as part of your new instrument budget proposal or purchase order will enable your laboratory to: ■ Fix the cost of ownership of mission critical or revenue generating instrumentation ■ Ensure seamless continuation of support when the initial 12-month warranty expires ■ Eliminate administration costs incurred by continually renewing contracts ■ Avoid having to re-justify maintenance expense at a future date ■ Make use of funds now that may not be available in the future Call your local sales representative to learn more about the PerkinElmer service and support products that the most successful global corporations, research facilities and analytic laboratories use to enhance their performance. Three service plan options are available to meet your needs PerkinElmer’s range of multi-year service plans eliminates the risk of unbudgeted service expense and ensures instrumentation is maintained to the highest possible standard throughout its lifetime. Comprehensive This plan is ideal for laboratories whose financial success depends on the consistent availability and high performance of their scientific instruments. Basic This plan is ideal for medium to large laboratories that require predictable instrument performance. Repair The Repair service plan is ideal for small to medium laboratories seeking to maximize limited maintenance budgets and maintain instrument performance. Three Options of Service Plan Packages PerkinElmer Service Benefits Comprehensive Maximum Uptime Basic Managed Expense Repair Dependable Protection Core Benefits Priority On-Site Response Preventative Maintenance Training PerkinElmer Certified Parts Expert Service Engineers Travel to your Location Within 48 hours 2 Annual Visits 15% off 100% included 100% included 100% included 1 Annual Visit 5% off 100% included 100% included 100% included 100% included 100% included 100% included Additional Features Online Support Resources Responsive Technical Support Service History Tracking Six Sigma & ISO Best Practices 100% included 100% included 100% included 100% included 100% included 100% included 100% included 100% included 100% included 100% included 100% included 100% included Order online at www.perkinelmer.com/supplies ORDER TODAY 59 PerkinElmer products — proven quality, reliability and results. NEW PRODUCTS PerkinElmer—The Clear Choice in Chromatography Hydrogen Generators! The newest membrane technology for safe production of pure hydrogen gas. See page 56 for details. 3-Cartridge Gas Purification System See pages 35 for details. Marathon Filament for PerkinElmer GC/MS Systems See page 31 for details. Portable Gas Leak Detector! Compact handheld detector with audible alarm. IR Temperature Gun! Low-cost, non-contact temperature measurement with laser sighting. See pages 36 for details. See page 36 for details. Colored Syringes with New Blue Barrel design. Enhanced visual sample volume verification. SAVE 5 and 10 piece syringe packs See pages 38 for details. Order online at www.perkinelmer.com/supplies 008977_01 PerkinElmer, Inc. 710 Bridgeport Avenue Shelton, CT 06484
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement