Siemens Solar Electric Modules Installation Guide
Siemens Solar Electric Modules are designed to produce DC electricity when exposed to sunlight or other light sources. They come with a permanently attached junction box that will accept a variety of wiring applications or with a special cable assembly for ease of installation. The modules are recommended to be installed by qualified professionals only.
Advertisement
Advertisement
SIEMENS
GENERAL INSTALLATION GUIDE
for Siemens Solar Electric Modules
1. INTRODUCTION
This Guide contains application and safety information with which you should be familiar before using your
Siemens Solar photovoltaic modules.
Your authorized Siemens Solar distributor or dealer can provide additional sizing and system design information if necessary.
Disclaimer of Liability
Since the use of this Guide and the conditions or methods of installation, operation, use and maintenance of the module are beyond Siemens Solar control, Siemens Solar does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way connected with such installation, operation, use or maintenance. No responsibility is assumed by Siemens
Solar for any infringement of patents or other rights of third parties which may result from use of the module.
No license is granted by implication or otherwise under any patent or patent rights. The information in this Guide is based on Siemens Solar knowledge and experience and is believed to be reliable; but such information including product specifications (without limitations) and suggestions do not constitute a warranty, expressed or implied. Siemens Solar reserves the right to make changes to the product, specifications, or Guide without prior notice.
General Information
The installation of solar modules requires a great degree of skill and should (if DC voltage exceeds IOOV: must) only be performed by a qualified licensed professional, including, without limitation, licensed contractors and licensed electricians. The installer assumes the risk of all injury that might occur during installation, including, without limitation, the risk of electric shock. Siemens Solar modules do not require the use of special cable
Part No. (019831) REV. E assemblies. All modules come with a permanently attached junction box that will accept a variety of wiring applications or with a special cable assembly for ease of installation.
WARNING
411
instructions should be read snd understood before mttempting to install, wire,
Dperate and maintain the photovoltaic module.
Contact
with electrically active paris of the module such as terminals can result in burns, sparks, and lethal shock whether the module is connected or disconnected.
Photovoltaic modules produce electricity when sunlight or other sources illuminate the front face. The voltage from a single module is not considered a shock hazard. When modules are connected in series, voltages
are additive. When modules are connected in parallel, current is additive. Consequently, a multimodule system can produce high voltages and current which constitute an increased hazard
and could cause serious injury 01 death.
.
CA UT/O/W
Avoid electrical hazards when installing, wiring, operating and maintaining the module.
A phofovolfaic module generates
DC electricity when exposed to
sunlight or other light sources.
When installing or working with module or wiring, cover module f a c e c o m p l e t e l y w i t h o p a q u e
m a t e r i a l to halt production of electricity.
.
l
.
.
.
.
.
.
.
.
.
If i s r e c o m m e n d e d t h a t t h e module remains packed in the box until time of installation.
Do not touch terminals while
module is exposed to light or during installation.
Provide suitable guards to prevent contact with 30VDC or greater.
As an added precaution, use properly insulated tools only.
Do not drop module or allow
objects to fall on module.
Do not stand or step on module.
It must be assured that other system c o m p o n e n t s d o n o t g e n e r a t e a n y h a z a r d o f a n y mechanical or electrical nature to the module.
Since sparks may be produced, do n o t install module where flammable gases or vapors are present.
Never leave a module unsupported or unsecured. If a module should fall, the glass can break.
A module with broken glass cannot be repaired and must not be used.
Work only under dry conditions, with dry module and tools.
Module installation and operation
should be performed by qualified personnel on/y. Children should not be allowed near the solar electric installation.
If not otherwise specified, if is
recommended that requirements of the latest local, national or regional followed, electric c o d e s b e
U s e m o d u l e f o r i t s i n t e n d e d function only. Follow all module manufacturer’s instructions. Do not dis-assemble the module, or remove any part or label installed by the manufacturer. Do not treat the back sheet with paint or adhesives.
Do not artificially concentrate sunlight on
the
module.
Retain this instruction booklet for future reference.
The word “module” as used in
this Guide refers to one or m o r e
photovoltaic modules.
1
2. GENERAL SAFETY
.
.
.
.
.
.
Inspection Requirements
Before installing module, contact appropriate a u t h o r i t i e s t o determine permit, installation and inspection requirements that should be followed. This should be done not only for installations in conjunction with buildings, but also for marine and motor vehicle applications for which additional requirements may apply.
Electrically ground module(s) for all systems of any voltage (US only).
If not otherwise specified, it is recommended that the latest
National and International
Electrical Code requirements be followed.
For roof mounted modules, special construction m a y b e required to help provide proper installation. Both roof construction and module installation design have an effect on the fire resistance of the building.
Improper installation may contribute to hazards in the event of fire. Additional devices such as ground fault, fuses and disconnects may be required.
Do
not use modules of different configurations in the same system.
Follow all safety precautions of other used components.
Underwriters Laboratory
Listing Information (US
Only):
To satisfy the conditions of the UL
Listing when installing the modules, be sure to:
1.
Use only stranded or solid copper single-conductor type UF cable, rated sunlight resistant, for modules and module wiring that is exposed to weather.
2.
3.
Observe the requirements described by note under Electrical
Characteristics.
Grounding of module frame is required.
When ground wires greater than No. 10 AWG are required, the installer will need to provide suitable terminal connectors to interface with the
No.10 binding screw provided with each module.
3. INSTALLATION
Modules should be firmly fixed in place in a manner suitable to withstand all expected loads, including wind and snow loads.
Part No. (019831) REV. E
Modules should be mounted with the orientation and tilt angle required for optimum performance
(seasonally, yearly). The location should be selected to prevent even partial shading from 9:00 a.m. to
3:00 p.m. (solar time) on the shortest day of the year.
Generally, the tilt angle can be calculated by using the site latitude plus 20 degrees, with modules facing south in the northern latitudes and north in the southern latitudes.
The mounting structure must withstand all snow and wind forces.
Mounting holes are provided for easy installation mechanical loading.
and proper
Do not drill additional mounting holes in the module frame as it will void the warranty.
The use of proper mounting hardware is recommended to minimize the possibility of corrosion of the module frame, mounting structure and hardware. Installing a laminate
(module without frame) use
Siemens module clamps.
. _
lntormation reaardina sDecial mounting irofilei -’ modules and laminates.
-for
Caution
C l e a r a n c e b e t w e e n t h e module frame and the mounting surface is
required to allow cooling
air to circulate around the back of the module. This also all0 ws any to dissipate. The module should never be sealed to the mounting surface with sealant that prevents air from circulating under the module.
4.
WIRING
General
All wiring should be done in accordance with applicable codes.
Wiring should be protected to help ensure personal safety and to prevent its damage.
Wiring connectors should be mechanically and electrically sound.
For connection to a battery, we recommend the use of a charge regulator (except SM46 and SM20).
All modules connected in series should be of the same model number/type. However, modules of different model numbers/types may be connected in parallel (see figure
8). Modules with the ProChargerTM
-CR junction box
-
Do not connect more than four modules in parallel.
Caution
Most of the module types contain factory installed bypass diodes. If these modules are incorrectly connected to a battery, the bypass diodes and junction box may be damaged.
.
.
Observe correct polarity:
Positive wire from module to regulator or battery positive terminal
Negative wire from module to regulator or battery negative terminal
Array Wiring
The term “array” is used to describe the assembly of several modules on a support structure with associated wiring. Use copper wire that is sunlight resistant and is insulated to withstand the maximum possible system open circuit voltage. Check your local codes for requirements.
Figure 8 Series and parallel wiring
Series wiring will increase voltage
Parallel wiring will increase current
Earth Ground Wiring
Each framed module has a hole in the side frame rail for connection of a ground wire. A No. IO binding screw and washer is provided with each m o d u l e ( n o t i n c l u d e d w i t h t h e
SM110/SM100 module) to connect a ground wire to the module metal frame.
US only: This assembly must be performed for a safe and proper installation. Other accessories provided are for optional use.
To install ground wire, first install screw with cup washer partially into hole. If the wire is insulated, strip insulation back approximately 5/8” (16mm) from the end of the wire and wrap wire around screw between its head and the cup washer. Tighten screw. The cup washer may be omitted if the wire is provided with a terminal lug.
The ground wire should also be attached to the support structure.
2
Module Terminations
The are four types of terminal enclosures used for electrical connections on Siemens modules. In addition, wire is also used to provide for electrical connections.
Refer to figures 1 through 7 to determine which type of connection is provided with your module.
4.1 Wiring Modules with a
Single ProChargerTM-CR
Junction Box
General
Wire terminals are accessible by removing the j-box lid.
Remove
the lid by loosening its two captive screws with a small flat or Phillips screwdriver.
Wire size must range from 1.5 mm2 to
10 mm2 (8 AWG to 14 AWG). The use of wire lugs is not required or recommended, but is possible. Once wiring is complete, install the j-box lid and tighten both screws to 0.5 - 0.7 Nm
(4 - 6 in-lb).
J-box configuration and description of terminals
Modules equipped with one j-box, contain terminals for both positive and negative polarity, user-selectable
6V/l2V voltage wiring and by-pass diodes. Refer to Figure 1 for terminal description.
Figure
1 - Modules with Single
ProChargerTM -CR J-Box
Description of Terminals
Internal wiring terminals with:
- connection to solar cells
- bypass diodes
- jumper(s)
See figure 9 for voltage selection
User-interface terminals with:
- (2) positive terminals (+I
-
(2) negative terminals (-1
- (2) isolated or spare term
Internal wiring of module and voltage selection
Terminals for internal wiring of module and voltage selection are adjacent to the slotted opening at the j-box bottom and protected with a small cover.
These terminals are factory-wired with interconnection to the solar cell ribbons and by-pass diodes for 12 V D C operation.
User does not need to access these terminals, except for the replacement of a broken diode or to change the operating voltage of the module. Figure 9 describes the wiring for selecting the desired operating voltage. The cover is a diode shield and must be placed back on its
Part No. (019831) REV. E mounting posts after completion of a repair. The schematics engraved in this cover remind the
user
of the correct wiring for 6V options.
User-interface terminals
(external) wiring stripped wire into knockout hole and pierce through foam seal. An awl or other sharp tool can be used to pierce through the foam seal.
Feed appropriate length of wire to reach terminal screw.
Insert stripped wire between terminal plate and square
Figure 9 Selection of operating voltage screw washer.
Tighten screw
to
2.3 Nm 120 in-lb).
3ypass diodes note direction)
12V jumper 6V jumpers provided in installation kit
/ (jumpers must not touch each other)
L i q u i d - t i g h t
I/2” fitting
(NPT 4”)
Remove knockout plug with s c r e w - d r i v e r
The j-box provides six IO-32 terminal screws for external wiring of the module. Two terminals are dedicated to each polarity (with the polarity symbols engraved into the j-box floor).
Two spare terminals (i.e. floating, not
Bypass diodes not required placed close to perimeter rim and driver impact with hammer. Use of a UL recognized liquid-tight l/2” fitting is required to seal and strain relief the wire/cable installed. Follow the fitting manufacturer’s recommendations for installation and use. Install fitting on connected to the module circuit) can be used for other applications such as blocking diodes.
box but leave it loose. Feed the wire through fitting and route it to terminal screw.
Connect wire as described above.
Complete tightening of the liquid-tight fitting.
Wire entry and connections
There are three methods of wire entry to the j-box. Refer to Figure 2.
Figure 2 - Wire Feedthrough Options
ProChargerm -CR J-Box
Conduit
For applications where wire conduits are used, follow the applicable codes for outdoor installation of wires in conduits.
Verify that all fittings are properly installed to secure wires against damage and prevent moisture intrusion.
Following conduit installation and wire length adjustment, connect wire as described above.
1 f2” Liquid tight fitting
Direct wire penetration with elastomer seal
Only one wire should be fed through each small diameter knockout. Remove knockout plug with screwdriver using moderate impact.
Slide the rubber foam seal in the cavity in front of the knockouts and push it down and flat all the way with a screwdriver. Strip wire insulation to 16mm (5/8”). Insert the
Strain Relief
No additional wire strain relief is required. However, it is recommended that strain relief be used to secure the wire or cable to the j-box. Two posts are provided to accept cable ties for this purpose.
4.2 Wiring Modules with
Two ProChargerTM-CR
Junction Boxes
M o d u l e s e q u i p p e d w i t h t w o separate weather-protection jboxes contain terminals for electrical connections. One j-box houses the positive output connections and the other j-box houses the negative output connections.
Both j-boxes also include by-pass diodes. Refer to figure 3 for terminal description.
3
Figure 3 - Modules with two
ProChargerTM -CR J-Boxes
Positive J-Box
Negative J-Box
Wire entry and connections
There are three methods of wire entry to the j-box. Refer to Figure 2.
4.3 Wiring Modules with a
Single ProChargerTM -S
Junction Box
General
Refer to section 4.1 “General”.
J-box configuration and description of terminals
Modules equipped with one j-box, contain terminals for both positive and negative polarity. Refer to Figure 4 for terminal description.
Figure
4 -
Modules with Single
ProChargerTM -S J-Box
Wire entry and connections
Refer to section 4.1 “Direct Wire
Penetration with Elastomer Seal”.
4.4 Wiring Modules with
Two ProChargerm -S
Junction Boxes
M o d u l e s e q u i p p e d w i t h t w o separate weather-protection jboxes contain terminals for
;:;r-sat yh;nections. One j-box positive output connections and the other j-box h o u s e s t h e n e g a t i v e o u t p u t connections.
Both j-boxes also include by-pass diodes. Refer to figure 5 for terminal description.
Figure 5 - Modules with two ProChargerTM -S J-
Boxes
Wire entry and connections
R e f e r t o section “Direct Wire
Penetration with Elastomer Seal”.
4.5 Wiring Modules with
Two Sp Junction Boxes
There are two weather protected terminal covers, one for positive termination and one for negative termination. Access to the terminal cover is obtained by unscrewing the 4 screws of the lid. Each terminal has provision for attaching one wire, which can range from 1.5 mm2 to 4 mm2 (12 to 16 AWG) in size. To install wire, first strip insulation back 16mm (5/8”). Do not lubricate wire. Insert stripped wire through strain relief and under marked terminal screw slider. Check the correct polarity of wire and terminal. Tighten screw securely using a screwdriver of the proper size and check if it’s fixed.
Use proper wrench to tighten the strain relief. When completed verify that the strain relief is secured correctly by pulling the cable.
Upon completion of wiring, set the terminal lid in place and tighten all 4 screws. The special design of the cover eliminates the need for a gasket. Do not attempt to seal lid to box.
4.6 Wiring Modules with
One Sp Junction Box
There is one weather protected terminal cover for positive and negative termination.
Access to the terminal cover is obtained by unscrewing the 4 screws of the lid. The terminal has provision for attaching one wire for each polarity, which can range from 1.5
mm2 to 4 mm2 (12 to 16 AWG) in size.
Connect wires as described above.
4.7 Wiring Modules with
Wire or Cable Termination
Crimped connectors are recommended.
Wires s h o u l d b e soldered if connections are made by splicing wires together. Connections should be protected against corrosion and shortcircuiting.
Warning
The
voltage from
a single module is not considered a shock hazard.
Do not install two or more modules
in series to make higher voltages.
These small solar modules are designed for 12-volt systems only.
Suggested wire sizes and lengths are as follows (longer distances require larger size wire):
Model Distance Wire Size
SM6/ST5 up to 25 feet AWG 18
SMlO/STlO up to 25 feet AWG 16
SM20/ST20 up to 25 feet AWG 14
4.8
Self-Regulation
This information applies to modules with 30 solar cells in series (SM20 and
SM46).
Part No. (019831) REV. E 4
In operation, the charging current provided to the battery by this module decreases as the battery voltage increases; thus, a battery at a low state of charge will accept more charging current than one which is at or near a full state of charge, If the system is used during the day, the charging current will continuously adjust to replace the energy used.
To obtain the benefit of self-regulation:
1.
Use proper minimum battery size of
IOOAH for each module.
2.
Install the module and battery so that the air temperatures around them are similar; within 20°F (-7°C).
3.
Use the system regularly.
The current from a self-regulating module to a fully charged battery may overcharge the battery if the system is not used frequently. The amount of overcharge may result in undesirable consumption of electrolyte, but should not damage the batfefy.
The factory-installed diodes provide proper circuit protection without the need for additional diodes in most systems. If, however, it is necessary to parallel modules within series strings, proceed as follows:
Connect modules in parallel with internal bypass diodes intact and place one large external diode around the parallel group.
Each external bypass diode should be properly rated and provided with a heat sink, if necessary. The external diode is required because the small internal diodes may not share current flow equally with this wiring arrangement.
6. MAINTENANCE
Minimal maintenance is required to maintain optimal module performance. If the module becomes dirty, a reduction in energy output may result.
We recommend the use of water and a soft cloth or sponge to clean the glass module surface.
A mild non-abrasive detergent may be used on persistent contaminants.
We recommend a semi-annual inspection of all electrical and mechanical connections for cleanliness, tightness and absence of damage. Protect yourself against possible electric shock during maintenance. Have a professional correct any problems found.
Modules with Wire or Cable Termination
Figure 6 Diode placement and polarity
If it is not possible to meet these requirements, it will be necessary to use a charge regulator.
5. DIODES
Blocking Diodes
These devices prevent current flow from the battery to the solar module when the module is not generating electricity.
The use of blocking diodes, such as a
Schottkys barrier type, is recommended in most applications where diodes are required. We also recommend the use of a charge controller.
The controller normally has circuitry to prevent reverse current, while protecting the battery against overcharging.
When using a charge controller, a blocking diode may not be required. Contact your authorized
Siemens Solar distributor or dealer for proper diode type.
Refer to the wiring diagram (figures 6 & 7) for diode placement and polarity.
Bypass Diodes
Shading of individual cells and modules in series strings can cause a reverse voltage across the cell or module.
Because current is forced through the shaded area by other series cells, undesirable heating can occur. The use of a diode to bypass the shaded area can minimize both heating and reduction of array current. All
Siemens modules with the exception of the SM6, SMIO, SM20, ST5, STIO, ST20 and SRSO-Z incorporate factory installed bypass diodes.
Figure 7 ‘Controller/regulator placement
Black
I
1 Bad
-J
Fuse
.
Black
nma to
protact Load
FUBS to protect bad
+
Battery
>
Load
I!?
Part
N
O
.
(019831)
REV. E
5
____
7. LIMITED WARRANTY
SIEMENS SOLAR ELECTRIC
(PHOTOVOLTAIC
1
MODULES
Limited Warranty - One Year Repair,
Replacement or Refund Remedy
Siemens Solar warrants the modules to be free from defects in materials and workmanship under normal application, installation, use and service conditions. If the product fails to conform to this warranty, then for a period ending twelve (12) months from date of sale to the original consumer purchaser, Siemens Solar will, at its option, either repair or replace the product, or refund the purchase price.
The repair or replacement or refund remedy shall be the sole and exclusive remedy provided under the warranty and shall not extend beyond the twelve
(121 month period set forth herein.
Limited Warranty
-
Limited Remedy
For modules ST5, STIO, STZO, ST40:
If, within five (5) years from the date of sale to the original consumer purchaser, any module(s) exhibits a power output less than 90% of the minimum power specified at time of delivery, then, provided that such loss in power is determined by Siemens
S o l a r ( a t i t s s o l e a n d a b s o l u t e discretion) to be due to defects in materials or workmanship, Siemens
Solar will replace such loss in power by either providing to the buyer additional modules to make up the total wattage loss, or by repairing or replacing the module, at the option of Siemens Solar.
Limited Warranty
-
Limited Remedy
For modules SM6, SMlO, SM20, SP18,
SP36, SM46, SMSO-H, SM50, SR50,
SR50-Z, SM55, SMIOO, SMIIO, SM130,
SP65, SP70 and SP75, SR90, SRIOO:
If, within ten (IO) years from the date of sale to the original consumer purchaser, any module(s) exhibits a power output fess than 90% of the minimum power specified at time of delivery, then, provided that such loss in power is determined by Siemens
S o l a r ( a t i t s s o l e a n d a b s o l u t e discretion) to be due to defects in materials or workmanship, Siemens
Solar will replace such loss in power by either providing to the buyer additional modules to make up the total wattage loss, or by repairing or replacing the module, at the option of Siemens Solar.
For modules SM46, SMSO-H, SM50,
SR50, SM55, SR90, SRlOO, SMIOO,
SMI 10, SM130, SP65, SP70 and SP75:
If, within twenty-five (25) years from the date of sale to the original consumer purchaser, any module(s) exhibits a power output less than 80% of the minimum power specified at time of delivery, then, provided that such loss in power is determined by Siemens
S o l a r ( a t i t s s o l e a n d a b s o l u t e discretion) to be due to defects in materials or workmanship, Siemens
Solar will replace such loss in power by either providing to the buyer additional modules to make up the total wattage loss, or by repairing or replacing the module, at the option of Siemens Solar.
T h e r e m e d y set forth in these paragraphs shall be the sole and exclusive remedy provided under the extended term warranty. The limited warranties set forth herein do not apply t o a n y m o d u l e w h i c h i n S i e m e n s
Solar’s sole and absolute judgment has been subjected to misuse, neglect or accident, or which has been damaged through abuse, alteration, improper i n s t a l l a t i o n o r a p p l i c a t i o n , o r negligence in use, storage, transportation or handling, or has been repaired, or in any way tampered with by anyone other than Siemens Solar.
The limited warranties do not cover any transportation costs for return of module, or for reshipment of any repaired or replaced module, or cost associated with installation, removal or reinstallation of modules.
“THE LIMITED WARRANTIES SET
FORTH HEREIN ARE EXPRESSLY IN
LIEU OF AND EXCLUDE ALL OTHER
EXPRESS OR IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO
WARRANTIES OF MERCHANTABILITY
AND OF FITNESS FOR PARTICULAR
PURPOSE, USE, OR APPLICATION,
AND ALL OTHER OBLIGATIONS OR
LIABILITIES ON THE PART OF SIEMENS
SOLAR, U N L E S S S U C H O T H E R
WARRANTIES, OBLIGATIONS OR
LIABILITIES ARE EXPRESSLY AGREED
T O I N W R I T I N G S I G N E D A N D
APPROVED BY SIEMENS SOLAR.
SIEMENS SOLAR SHALL HAVE NO
RESPONSIBILITY OR LIABILITY
WHATSOEVER FOR DAMAGE OR
INJURY TO PERSONS OR PROPERTY,
OR FOR OTHER LOSS OR INJURY
R E S U L T I N G F R O M A N Y C A U S E
WHATSOEVER ARISING OUT OF OR
R E L A T E D T O THE PRODUCT,
INCLUDING, WITHOUT LIMITATION,
ANY DEFECTS IN THE MODULE, OR
FROM USE OR INSTALLATION. UNDER
NO CIRCUMSTANCES SHALL
SIEMENS SOLAR BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL OR
SPECIAL DAMAGES, HOWSOEVER
CAUSED.
S IE M E N S SO L AR’S AGGR E GA TE
LIABILITY, IF ANY, IN DAMAGES OR
OTHERWISE, SHALL NOT EXCEED THE
PAYMENT, IF ANY, RECEIVED BY
SELLER FOR THE UNIT OF PRODUCT
OR SERVICE FURNISHED OR TO BE
FURNISHED, AS THE CASE MAY BE,
WHICH IS THE SUBJECT OF CLAIM OR
DISPUTE.
S O M E S T A T E S D O N O T A L L O W
LIMITATIONS O N IMPLIED
WARRANTIES OR THE EXCLUSION OR
LIMITATION OF DAMAGES, SO THE
ABOVE LIMITATIONS OR EXCLUSIONS
MAY NOT APPLY TO YOU.”
Obtaining Warranty Performance
F i l l o u t a n d r e t u r n t h e W a r r a n t y
Registration Card, if supplied with the module, within thirty (30) days after purchase. Failing to return the card will n o t a f f e c t y o u r r i g h t s u n d e r t h e warranty so long as you can establish the date on which you purchased the module.
If you feel you have a claim covered by warranty, you must immediately notify the dealer who sold you the module or any authorized Siemens Solar distributor of the claim. Check local telephone listings for location.
The dealer or distributor will give advice on handling the claim. If further assistance is required, write Siemens Solar for instructions.
The return of any modules will not be accepted by the factory unless prior written authorization has been given by
Siemens Solar.
Severability
If a part, provision or clause of the terms and conditions of sale, or the application thereof to any person or circumstance, is held invalid, void or unenforceable, such holding shall not affect and shall leave all other parts, provisions, clauses or applications of the terms and conditions remaining, and to this end the terms and conditions shall be treated as severable.
Disputes
No action, regardless of form, arising out of or in any way connected with the products or services furnished by
Siemens Solar, may be brought by the customer or purchaser more than one
(I) year after the cause of action has accrued.
THIS WARRANTY GIVES YOU SPECIFIC
LEGAL RIGHTS; AND YOU MAY ALSO
HAVE OTHER RIGHTS THAT VARY
FROM STATE TO STATE.
Force Majeure
Neither party shall be in any way
Part No.
(019831) REV. E
6
responsible or liable to the other party, or to any third party, arising out of nonperformance or delay in performance of the terms and condition of sale due to acts of God, war, riots, strikes, unavailability of suitable and sufficient labor, material, die, or capacity or technical or yield failures and any unforeseen event beyond its control, including, without limitations, any technological or physical event or condition which is not reasonably known or understood at the time of sale.
Part No. (019831) REV. E 7
Siemens Solar GmbH
A joint venture of Siemens AG and Bayernwerk AG
Postfach 46 07 05
D-80915 Miinchen
Germany
Tel:
Fax:
49-89-636-59-158
49-89-636-59- 173
Siemens Solar Industries
PO. Box 6032
Camarillo, CA 93011, U.S.A.
Tel: 805-482-6800
Fax: 805-388-6395
Web site: www.siemenssolar.com
E-mail: [email protected]
Siemens Showa Solar Pte. Ltd.
166 Kallang Way
Singapore 349249
Tel: 65-842-3886
Fax: 65-842-3887
Part No. (019831) REV. E
Download
Advertisement
Key features
Designed for various applications
Self-regulating
Weatherproof
Easy installation
High efficiency
Durable
Frequently asked questions
There are four types of terminal enclosures used for electrical connections on Siemens modules: ProChargerTM-CR junction box, ProChargerTM-S junction box, Sp junction box, and wire or cable termination.
The recommended wire size for connecting Siemens modules to a battery depends on the distance between the module and the battery. For distances up to 25 feet, AWG 18 wire is recommended. For longer distances, larger wire sizes are required.
To clean a Siemens solar module, use water and a soft cloth or sponge. A mild non-abrasive detergent can be used on persistent contaminants.
The warranty on a Siemens solar module varies depending on the model. For example, the SM20 module has a 10-year warranty on power output. Refer to the warranty section of the installation guide for details on the warranty for your specific module.