Eaton | Powerware 9155 | Eaton 9155 UPS - A-TRAC

Powerware series
Eaton 9155 UPS
8-15 kVA
Product Introduction
Product Snapshot
Technology:
Split-phase double-conversion online UPS
Power Rating: 8 kVA, 10 kVA, 12 kVA and 15 kVA at 0.9 power factor
Input Voltage: 200–240 Vac with Neutral or with optional input isolation transformer
Output Voltage:
100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement
Frequency:
50/60 Hz auto-sensing
Dimensions: 32.2” H x 12” W x 32.5” D
Configuration: Small-footprint tower, black
Battery Backup: 9155 8-15 kVA
Features of the Eaton 9155 UPS
• A true online, double-conversion topology protects connected
equipment from all nine of the most common power problems
• Delivers maximum power density in a compact tower design:
12” wide and 33” deep, including batteries
• Provides more real power in less space (5,500 watts per square
foot) with a 0.9 output power factor – protecting more equipment for every utility dollar and leaving more room for expansion of the data center
• Patented Powerware Hot Sync® paralleling of multiple modules
delivers extra capacity or redundancy
• Customizable output distribution provides user-specified power
outlets along with terminals for connecting hard-wired equipment
• Microprocessor-controlled ABM® technology significantly
increases battery life
• Provides a 0.99 input power factor and generator friendly <5%
total harmonic distortion using an active IGBT rectifier to
control the input power factor
• Ensures data and system integrity with complete power management software for remote monitoring, management and
shutdown
• An Eaton factory limited warranty, technical support and
optional service plans provide investment protection and peace
of mind
2
eaton corporation
9155 UPS
Up to 29 minutes typical, extendable up
to four hours (See battery backup charts)
Reliability and efficiency have never looked so
attractive.
The 9155 single-phase Uninterruptible Power System (UPS) delivers a combination of advanced technology, user-friendly design
and low price that's absolutely unmatched by competing products. This innovative design offers high efficiency (90 percent or
better across all load ranges), low input current distortion (less
than 5 percent total harmonic distortion, with an active IGBT rectifier that delivers 0.99 power factor correction) and high power factor output (0.9 PF).
With advances being made in miniaturization and processing
power and more equipment being served by dual-cord power
supplies, the challenge of protecting that power, and doing so in a
limited space, grows ever greater.
Fortunately, advances in technology have also meant that more
power protection per square foot can now be provided. Like the
Eaton 9355, the 9155 delivers premium levels of efficiency, reliability and flexibility, all in a sleek tower half the size of most
other units on the market today.
These double-conversion, online UPSs resolve all nine common
utility power problems and supply clean, continuous power to
all connected equipment. Even when presented with the most
severe power problems, power output remains stable. And if the
utility power goes out altogether, there is no delay transferring to
backup power.
These capabilities make the 9155 ideal for protecting essential
data center, communications and electrical engineering infrastructures in corporate, telecom, healthcare, banking, public sector and
industrial networks.
Premium power protection is now easier than ever.
With raised-floor real estate at a premium, you’ll appreciate that
the 9155 requires only three to six square feet of floor space,
including internal batteries. Such a small footprint gives you more
location options and more space available for future expansion.
Equipment installation is inexpensive and easy – essentially plugand-play. You can order 9155 models with your choice of more
than 19 types of output receptacles. To rearrange or add data
center equipment, you simply unplug from the old receptacle
and plug into a new one – no need for an electrician to run new
conduit and wiring.
Scalable architecture meets current and future load
requirements.
Eaton 9155 UPSs are available in four
models: 8, 10, 12 and 15 kVA, so you
can choose the configuration that most
closely meets your own capacity requirements and price point. And you can scale
from there. Using our signature Hot
Sync paralleling technology, up to three
9155 modules can be paralleled for extra
capacity or redundancy. A 15 kVA UPS,
for example, can grow to support loads
of up to 45 kVA. There's no dependence
on communications wiring among these
modules, enhancing reliability and simplifying installation. This paralleling capability Is far more easily achieved than is the
case with competitors' products.
Inside view of 9155 Parallel
Cabinet Maintenance Bypass
Powerware Hot Sync Redundant/Capacity
9155 UPS Parallel Cabinet
Load
Battery innovations optimize battery performance and service life.
Standard internal batteries provide power until auxiliary power takes over or systems are gracefully shut
down. Battery runtime can be extended to hours by adding matching Extended Battery Modules (EBM).
Eaton 9155 8-15 kVA UPS Backup Times (In Minutes)
Eaton 9155 8-15 kVA UPS Backup Times (In Minutes)
UPS
(1)
+ Internal EBM VA
Watt 32 Battery 64
15000 13500
4.6
23.0
14500 13050
4.9
24.1
14000 12600
5.2
25.2
13500 12150
5.5
26.4
13000 11700
5.8
27.6
12500 11250
6.1
28.8
12000 10800
6.5
30.2
11500 10350
6.9
31.6
11000 9900
7.3
33.3
10500 9450
7.8
35.1
10000 9000
8.4
37.2
9500
8550
9.1
39.6
9000
8100
9.9
42.3
8500
7650
10.8
45.5
8000
7200
11.9
49.1
UPS
(1)
(2)
(3)
(4)
UPS
+ Internal EBM EBM EBM EBM + Internal
VA
Watt 32 Battery 64
64
64
64 64 Battery
7500
6750
13.1
53.2 99.7 151
205
32.3
7000
6300
14.6
58.0 109
164
224
35.2
6500
5850
16.3
63.5 119
180
245
38.6
6000
5400
18.4
70.0 131
198
270
42.5
5500
4950
20.1
77.6 145
220
300
47.2
5000
4500
22.4
86.6 162
245
334
52.6
4500
4050
25.2
97.4 182
276
376
59.2
4000
3600
28.6
110
207
313
426
67.1
3500
3150
32.8
127
238
359
-
77.0
3000
2700
38.3
148
277
418
-
89.7
2500
2250
45.6
176
329
-
-
107
(2)
EBM 64
43.0
45.2
47.3
49.4
51.6
54.0
56.5
59.3
62.4
65.9
69.8
74.2
79.4
85.2
91.9
(3)
EBM 64
65.1
68.3
71.5
74.7
78.1
81.6
85.5
89.7
94.4
99.6
106
112
120
129
139
(4)
UPS
(1) EBM + Internal EBM 64 64 Battery 96
88.6
13.3
43.0
93.0
14.1
45.2
97.4
14.9
47.3
102
15.8
49.4
106
16.7
51.6
111
17.6
54.0
116
18.6
56.5
122
19.2
59.3
129
20.2
62.4
136
21.4
65.9
144
22.6
69.8
153
24.1
74.2
163
25.7
79.4
175
27.6
85.2
189
29.8
91.9
(2)
(3)
EBM EBM
96
96
76.7 113
80.5 119
84.2 125
88.1 130
92.0 136
96.2 142
101
149
106
156
111
164
117
174
124
184
132
196
141
209
152
225
164
242
(1) (2)
(3)
EBM EBM EBM
96
96
96
99.7 178
263
109
194
286
119
212
314
131
234
346
145
259
383
162
289
428
182
325
207
369
238
423
277
-
329
-
-
Note: Backup times are approximate and may vary with equipment, configuration, battery
age, temperature, etc.
www.eaton.com/9155
1.800.356.5784
3
Front view
Rear view
After 15 years of in-service experience, Eaton
has real-world proof that ABM technology
can significantly increase battery service life.
Advanced design delivers unequaled power performance.
Lower costs, lower temperatures. High efficiency (greater than 90
percent across all load ranges) reduces utility costs, extends battery
runtimes and produces cooler operating conditions.
Generator-friendly design. Total input harmonic distortion (THD)
remains below five percent without compromising overall efficiency.
The result is maximum transfer of power between source and protected load and exceptional compatibility with auxiliary generators.
10-20% more real power. On the output side, a high (0.9) power
Eaton 9155
The 9155 uses sophisticated technologies that maximize the health
and service life of batteries:
factor enables the 9155 to provide more real power to modern IT
equipment that may have a wide range of leading and lagging power
factors. And, with a 0.99 input power factor, these UPSs avoid the
disturbances energy converters tend to cause.
• ABM technology uses a unique three-stage charging technique
that significantly extends battery service life and optimizes recharge time (compared to traditional trickle charging).
• Temperature-compensated charging monitors battery
temperature and adjusts the charge rate accordingly, which
properly charges the battery and greatly extends battery life.
• An integrated battery management system tests and monitors battery health and remaining lifetime, providing notification to guide preventive maintenance.
Unlike heavy, old-style batteries, Eaton's batteries are easily
field-replaceable. One person, working alone, can replace a battery
without disrupting data center operations or power to protected
equipment.
Protect your investment
Rest easy knowing your UPS is always on the job.
While it protects your critical systems, the 9155 UPS itself is protected in several ways:
Self-diagnosis. The 9155 constantly monitors its own operation –
such as voltage, temperature or function of internal elements – and
sends alarms or takes action if it detects a potential problem. You’ll
know your UPS is always performing up to specifications to protect
your equipment.
Self-correction. If it senses an issue – planned or unplanned – the
9155 instantly transfers the power path to a bypass source with zero
interruption to power. When the alarm condition passes, the UPS
automatically reverts from bypass to normal power.
4
eaton corporation
9155 UPS
Remote monitoring. You can choose to have Eaton specialists
securely monitor your 9155 UPSs around the clock with eNotify
service or opt to monitor your own UPSs over your LAN or the
Internet. Either way, you’ll always be informed of conditions in your
power protection infrastructure.
Redundancy. Using Powerware Hot Sync technology, you can configure your 9155 for up to N+3 redundancy. Any module can serve
as backup for any other with no interruption or downtime. For
instance, you could perform full maintenance on any UPS without
having to remove any loads from conditioned power.
Most other paralleling systems on the market use a top-down configuration – and so if the master fails, the subsidiary units fail. With
Eaton’s patented approach, each UPS module is independent yet
synchronized with the others. There is no single point of failure.
Get central control and visibility of your UPS systems.
The 9155 Is shipped with a CD that includes
LanSafe™ power management software and
a 30-day trial version of PowerVision® UPS
performance analsis and monitoring software. Using an intuitive, graphical interface
and Simple Network Management Protocol
(SNMP), administrators can:
Gain peace of mind with industry-leading warranty
and service plans.
We're so confident in the performance and reliability of the 9155 and
its battery system that we back them up with extensive warranty
and service plans. Gain the peace of mind that comes with factory
warranty coverage (parts and labor, UPS and batteries) and rapid
response from certified support engineers:
Eaton
Software Suite
• Securely monitor UPS and battery performance over
your existing Ethernet network and the Internet
• Establish prioritized shutdown of network devices and
client/server applications
• Test all networked UPS systems from one node
• Analyze trends and network conditions
• 2-year limited factory warranty
• 10-year pro-rated warranty
• $250,000 load-protection guarantee
Beyond the warranty period, service plans are available to match any
need – from basic UPS and/or battery support to all-inclusive packages with unique features, such as advanced remote monitoring with
trending, customized capacity planning reports and power protection
audits. Add your choice of guaranteed response times, and you can
tailor just the right support package for your needs.
• Stay informed of potential power problems by pager and e-mail
Enjoy maximum flexibility with connectivity options.
The standard unit is equipped with an RS-232 serial port to communicate with power management software. You can customize your
9155 by adding one or two interface cards
for other applications:
Monitor the UPS from anywhere.
Connect your 9155 to your Ethernet
network and the Internet for secure
monitoring and management using
a standard Web browser or SNMP.
Interwork with your existing building
management system.
A Modbus® Card enables real-time monitoring of UPS systems through a building
management system or industrial automation system.
Gather information from relay contact
devices.
The package provides a dry-contact
interface between the 9155 and any relayconnected device, including the IBM®
e-server® iSeries and a variety of industrial
applications.
Independently manage diverse servers.
A Multi-Server card enables up to six serially connected devices of mixed operating
systems to be independently managed
and controlled by a single UPS.
Monitor environmental conditions. An
optional Environmental Monitoring Probe
remotely monitors temperature, humidity
and two user-supplied contacts/sensors,
such as smoke and intrusion detection.and
two user-supplied contacts/sensors, such
as smoke and intrusion detection.
ConnectUPSTM
Web/SNMP Card
From Eaton—a global leader in power quality
solutions.
Backed by 40 years of R&D excellence, the 9155 delivers confidence – confidence that your organization’s critical electronics are
protected by the most reliable, efficient and full-featured systems
available and that Eaton will be there with you for the long term with
premium warranty coverage and expert technical support.
Eaton is a global leader in power quality and management
solutions – the #1 manufacturer of UPSs above 5000 VA (Frost &
Sullivan; World UPS Markets, 2004). Eaton’s Power Quality Solutions
Operation is headquartered in Raleigh, North Carolina, U.S.
For more information on the Eaton 9155 UPS: www.eaton.com/powerquality
1.800.356.5794
Modbus Card
Relay Interface Card
Multi-Server Card
Environmental
Monitoring Probe
www.eaton.com/9155
1.800.356.5784
5
Eaton 9155 at-a-glance
Model selection table - eaton 9155 UPS (8–15 kVA)
Order Number1
Description
K408110000
PW9155 Model 8 - 32 Battery (2-high)
K408120000
PW9155 Model 8 - 64 Battery (3-high)
K408130000
PW9155 Model 8 - 32 Battery with Transformer (3-high)
K410110000
PW9155 Model 10 - 32 Battery (2- high)
K410120000
PW9155 Model 10 - 64 Battery (3- high)
K410130000
PW9155 Model 10 - 32 Battery with Transformer (3-high)
K412110000
PW9155 Model 12 - 32 Battery (2-high)
K412120000
PW9155 Model 12 - 64 Battery (3-high)
K412130000
PW9155 Model 12 - 32 Battery with Transformer (3-high)
K415110000
PW9155 Model 15 - 32 Battery (2- high)
K415120000
PW9155 Model 15 - 64 Battery (3- high)
K415130000
PW9155 Model 15 - 32 Battery with Transformer. (3- high)
Power Rating2
(kVA/kW)
8/7.2
8/7.2
8/7.2
10/9
10/9
10/9
12/10.8
12/10.8
12/10.8
15/13.5
15/13.5
15/13.5
Input & Output
Connection4
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Hardwired
Output Receptacles
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
See PDM chart
Dimensions Unit
H x W x D (in) Weight3 (lb)
32.2 x 12.0 x 32.0
352
47.8 x 12.0 x 32.0
590
47.8 x 12.0 x 32.0
558
32.2 x 12.0 x 32.0
352
47.8 x 12.0 x 32.0
590
47.8 x 12.0 x 32.0
558
32.2 x 12.0 x 32.0
352
47.8 x 12.0 x 32.0
590
47.8 x 12.0 x 32.0
558
32.2 x 12.0 x 32.0
352
47.8 x 12.0 x 32.0
590
47.8 x 12.0 x 32.0
558
1. 50/60 Hz auto-sensing. All models can be used for frequency/phase conversion with de-rated 80% load. Please refer to manual for details.
2. Input voltage 200–240V with neutral or with optional input isolation transformer. Output voltages are user-selectable 100/200, 110/220, 120/240 Vac 180° phase displacement, or 120/208, 127/220 Vac 120° phase displacement.
3. Weight is installed weight; add 47 lbs (2-high models) or 50 lbs (3-high models) to determine shipping weight.
4. An input neutral is required for all configurations unless the input isolation transformer is used.
eaton 9155 UPS warranty and service CHART
Service Plan Features
Limited Factory On-Site
Warranty Gold Plan
On-Site
Gold Plan
Plus
Service plan terms available
90 days on-site labor (5x8);
two years parts coverage
On-site startup of UPS and
batteries, 7/24
On-site corrective
maintenance, 7x24
Full coverage of UPS and internal
battery module
7x24 technical telephone
support
Service
priority
Full coverage of extended
battery modules
One 7x24 annual preventive
maintenance inspection
2 Yr
2, 3, 5 Yr
2, 3, 5 Yr
Service included
Optional service
6
eaton corporation
9155 UPS
Eaton 9155 Accessories
Accessories Order Number
Description
Dimensions H x W x D (in)
Unit Weight (lb)
Powerware Hot Sync 124100017-001 103004336
9155 Parallel Cabinet
Powerware HotSync CAN Bridge Card 24.0 x 20.3 x 2.2
-
57.3
-
Notes: Up to three 9155 UPS and up to four 9355 UPS (available Fall 2005) UPSs can be paralleled with the Parallel Cabinet.
Extended Battery Module (EBM) or Cabinets (EBC)
103004192-5501
103004193-5501
9155 and 9355 EBM 64 (2-high)
9155 and 9355 EBM 96 (3-high)
32.2 x 12.0 x 30.2
47.8 x 12.0 x 30.2
480
710
Notes: up to four EBM 64 cabinets or three EBM 96 cabinets can be added to each 8-15 kVA UPS for extended runtime. Seismic Mounting Kit
103004194-5501 Seismic Kit, Rated Zone 4, UL Tested, Performance rating
based on NEBS GR-63-CORE Standard Vibration Test Fits both 2- & 3-high models
136
Maintenance Bypass Module (MBM)
103004184-5501 BPE14MBB1A Rear UPS-mounted Maintenance Bypass Module Wall-mounted Maintenance Bypass Module for 9155
16.5 x 12 x 7 21 x 14 x 6.75 15
31
Eaton 9155 Parallel System Start Up
OSTUP9155P15KCX
OSTUP9155P10KCX
103004626
103004627
9155 8-10 kVA 2 or 3 Unit Parallel
9155 12-15 kVA 2 or 3 Unit Parallel
9155 Parallel System 2 unit upgrade kit (includes Can Bridge Cards, Procedures, and Parallel User's Guide)
9155 Parallel System 3 unit upgrade kit (includes Can Bridge Cards, Procedures, and Parallel User's Guide)
Connectivity Options
103002974-5501
05146288-5501
103002510-5501
05146508-5501
05146447-5501
1018460
103003055
103003637-5501
ConnectUPS-X Web/SNMP/xHub Card
ConnectUPS-MX SNMP/Modem Card (9155 only)
Modbus Card
USB Card
Multi-Server Card (9155 only)
Relay Interface Card (AS/400 Compatible)
Industrial Relay Card
Environmental Probe (requires ConnectUPS Web/SNMP card)
Spare Parts
106711155
9155 Spare Parts Kit "A"
Upgrades
103004195
103004196
9155 8 kVA to 9155 10 kVA
9155 12 kVA to 9155 15 kVA
Power Distribution Module (PDM) with Mechanical Bypass Switch
Optional Receptacle Panels
Breaker
Voltage
Phase
(1) L15-30R
30A
208V
3
(1) L21-20R
20A
208/120V
3
(1) L21-30R
30A
208/120V
3
(2) 5-15R
15A
120V
1
(2) 5-20R
20A
120V
1
(2) 6-15R
15A
208V
2
(2) 6-20R
20A
208V
2
(2) L5-15R
15A
120V
1
(1) L5-20R1
20A
120V
1
(1) L5-30R1
30A
120V
1
(2) L6-15R
15A
208V
2
(1) L6-20R1
20A
208V
2
(1) L6-30R1
30A
208V
2
(1) L14-20R1
20A
120/208V
2
(1) L14-30R1
30A
120/208V
2
(2) IEC 320 C13 (120V)
20A
120V
1
(2) IEC 320 C19 (120V)
20A
120V
1
Blank panel
Note: Maximum of eight panels per PDM (Eaton 9155).
1. The combined quantities of single-locking receptacle panels must not exceed five per PDM.
www.eaton.com/9155
1.800.356.5784
7
TECHNICAL SPECIFICATIONS for 10 AND 15 kVA
Power
Ratings (kVA/Watts)
8, 10, 12 and 15 kVA at 0.9 power factor
Topology
True double-conversion online UPS
Electrical Input
Nominal Input Voltage
200V-240V with neutral or with optional input transformer
Input Voltage Range
-15%, +10% from nominal at 100% load without depleting battery
Operating Frequency
50/60 Hz (45 to 65 Hz)
Input Power Factor
P.F >0.99 typical, >0.96 frequency converter
Input Current Distortion
5% THD
Electrical Output
Nominal Output Voltage
100/200, 110/220, 120/240 Vac 180° phase
displacement; 120/208, 127/220 Vac 120° phase displacement
Output Voltage Regulation
±1% Static; ±5% dynamic at 100% resistive load change, <1 ms response time
Efficiency
90% typical
Battery
Battery Type
9Ah, sealed, lead-acid, maintenance-free
Battery Runtime
See Battery Runtime Chart
Battery Replacement
Field-replaceable
Charger Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current)
Start-On-Battery
Allows start of UPS without utility input
General
Diagnostics
Full system self-test at startup
UPS Bypass
Automatic on overload or UPS failure
Parallel for Redundancy Yes, using Powerware Hot Sync technology
and Capacity
Dimensions and Weights
See Model Selection Table
Overload 150% for 5 sec / 125% for 1 min (online), (Normal Operation) 110% for 10 min
Communications
LCD Display
Graphical LCD with blue backlight
LEDs
(4) LEDs for notice and alarm
Audible Alarms
Yes
Communication Ports
(1) RS-232, (1) relay contact, (1) REPO,
(2) environmental input
Communication Slot
(2) X-Slot communication bays
Power Management Bundled Software Suite CD Software
Environmental
Operating Temperature
10ºC to +40ºC, +45ºC with 7.5% derating; Batteries recommended max. +25ºC
Storage Temperature
-15ºC to +25ºC
Relative Humidity
0–95%, non-condensing
Audible Noise
Audible Noise: < 53 dBA at 1 meter (noise less room) typical Altitude
< 1000m at +40°C, < 3000m at +25°C
Certifications
Safety Certifications
NOM-0190SCFI-1993, UL 1778, CSA C22.2, No. 107.3;
EN 5502 Class A (CISPR22 Class A) and IEC 60950;
IEC 62040-1-1
EMC Compliance
IEC 62040-2, FCC Part 15, ICES-003, VCCI
Quality
ISO 9001: 2000 and ISO 14001:1996
Markings
UL, cUL, CSA, CE and NOM-NYCE
Four button graphical LCD
with backlight
X-Slot Communication Bay #1
Fans
Signal Input 1
Signal Input 2
REPO (normally open)
REPO (normally closed)
X-Slot Communication Bay #2
DB-9 Communication Port
Relay Contact
Internal batteries on slide out
trays (field-replaceable)
Front view of 3-high module with
cover off
1. Due to continuous product improvements, program specifications are subject to change without notice.
UNITED STATES
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
www.eaton.com/powerquality
Canada
Ontario: 416.798.0112
Toll free: 1.800.461.9166
LATIN AMERICA
Brazil: 55.11.3616.8500
Caribbean: 1.949.452.9610
México & Central America:
52.55.9000.5252
South Cone: 54.11.4343.6323
Europe/Middle East/Africa
Denmark: 45.3686.7910
Finland: 358.94.52.661
France: 33.1.6012.7400
Germany: 49.0.7841.604.0
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Portugal: 55.11.3616.8500
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
Asia Pacific
Australia: 61.2.9693.9366
New Zealand: 64.0.3.343.3314
China: 86.21.6361.5599
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.4223.2300
Singapore/SEA: 65.6825.1668
Eaton, PowerChain Management, ABM,
ConnectUPS, LanSafe, PowerVision, Powerware
Hot Sync, and X-Slot are trade names, trademarks
and/or service marks of Eaton Corporation or its
subsidiaries and affiliates.
©2009 Eaton Corporation
All Rights Reserved
Printed in USA
9155FXA
June 2009
Download PDF