Bull NovaScale 5005 User's Guide

Add to my manuals
368 Pages

advertisement

Bull NovaScale 5005 User's Guide | Manualzz

NovaScale 5xx5

User's Guide

REFERENCE

86 A1 41EM 06

BLANK

NOVASCALE

NovaScale 5xx5

User's Guide

Hardware

September 2007

BULL CEDOC

357 AVENUE PATTON

B.P.20845

49008 ANGERS CEDEX 01

FRANCE

REFERENCE

86 A1 41EM 06

The following copyright notice protects this book under Copyright laws which prohibit such actions as, but not limited to, copying, distributing, modifying, and making derivative works.

Copyright Bull SAS 1992, 2007

Printed in France

Suggestions and criticisms concerning the form, content, and presentation of this book are invited. A form is provided at the end of this book for this purpose.

To order additional copies of this book or other Bull Technical Publications, you are invited to use the Ordering Form also provided at the end of this book.

Trademarks and Acknowledgements

We acknowledge the right of proprietors of trademarks mentioned in this book.

Intel and Itanium are registered trademarks of Intel Corporation.

Windows and Microsoft software are registered trademarks of Microsoft Corporation.

UNIX is a registered trademark in the United States of America and other countries licensed exclusively through the Open Group.

Linux is a registered trademark of Linus Torvalds.

The information in this document is subject to change without notice. Bull will not be liable for errors contained herein, or for incidental or consequential damages in connection with the use of this material.

Preface

Table of Contents

Intended Readers

Highlighting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Regulatory Specifications and Disclaimers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Declaration of the Manufacturer or Importer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Compliance Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

European Community (EC) Council Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Federal Communications Commission (FCC) Statement . . . . . . . . . . . . . . . . . . . . . .

FCC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Canadian Compliance Statement (Industry Canada) . . . . . . . . . . . . . . . . . . . . . . . .

Laser Compliance Notice

Definition of Safety Notices

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Laser Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Data Integrity and Verification

Waste Management

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAM Writing Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Illegal Characters

String Lengths

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Registry Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AZERTY/QWERTY Keyboard Lookup Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Administrator's Memorandum

Operator's Memorandum

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 1. Introducing the Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Bull Novascale Server Overview

Dynamic Partitioning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Extended Configurations

Cluster Configurations

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Server Features

Server Hardware

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Central SubSystem Module (CSS Module) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Front Unit

Core Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rear Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Platform Administration Processor (PAP) Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

KVM Switch

Console

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disk Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Additional Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Server Firmware and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Conformance to Standards

Getting to Know the Server

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NovaScale 5085 Partitioned Server

NovaScale 5165 Partitioned Server

NovaScale 5245 Partitioned Server

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-5

1-5

1-5

1-5

1-5

1-6

1-7

1-7

1-8

1-9

1-3

1-4

1-4

1-4

1-4

1-5

1-5

1-1

1-2

1-2

1-2

1-2

xviii

xix xix xix xix

xx xx

xxi

xvii xvii xvii

xviii xviii xviii

xxi xxi

xxii xxii

xxiii xxiii

xxiv

xxv

xxvii

Preface iii

NovaScale 5325 Partitioned Server

Server Components

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Central Subsystem (CSS) Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Integrated Platform Administration Processor (PAP) Unit . . . . . . . . . . . . . . . . . . . . . .

Integrated Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Keyboard / Video / Mouse (KVM) Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8-Port KVM Switch

16-Port KVM Switch

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

KVM Extender . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FDA 1x00 FC Disk Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FDA 2x00 FC Disk Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FDA 1x00 FC Extension Disk Rack

Ethernet Hub

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

USB Modem

NPort Server

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Accessing Server Components

Opening the Front Door

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Closing the Front Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Opening / Closing the Integrated Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Bull NovaScale Server Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

System Resource and Documentation CD-Roms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAM Software Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAP Unit Mirroring and Failover Policy

EFI Utilities

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 2. Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connecting to the PAM Web Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connecting to the PAM Web Site from the Local / Integrated Console . . . . . . . . .

Connecting to the PAM Web Site from a Remote Computer . . . . . . . . . . . . . . . . . .

Enabling Remote Access to the PAM Web Site with Internet Explorer,

Mozilla, or Firefox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Simultaneous Connection to the PAM Web Site

PAM User Interface

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking Server Status via PAM

PAM Status Pane

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAM Control Pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CSS Availability Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PAM Tree Pane

Setting up Users

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Toggling the Local / Integrated Console Display

Powering Up / Down Server Domains

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Powering Up the NovaScale 5xx5 SMP Server Domain . . . . . . . . . . . . . . . . . . . . .

Powering Down the NovaScale 5xx5 SMP Server Domain

Powering Up NovaScale 5xx5 Partitioned Server Domains

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . .

Powering Down NovaScale 5xx5 Partitioned Server Domains . . . . . . . . . . . . . . . .

Preparing Server Domains for Remote Access via the Enterprise LAN . . . . . . . . . . . .

Microsoft Windows Domain

Linux Redhat Domain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Linux SuSE Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preparing Server Domains for Remote Access via the Web

Microsoft Windows Domain

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Linux Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connecting to a Server Domain via the Enterprise LAN . . . . . . . . . . . . . . . . . . . . . . . .

Microsoft Windows Domain

Linux Domain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1

2-2

2-2

2-3

2-18

2-18

2-18

2-19

2-19

2-19

2-11

2-12

2-15

2-16

2-16

2-16

2-17

2-6

2-7

2-7

2-8

2-9

2-10

2-10

2-3

2-4

2-5

2-6

2-6

1-16

1-17

1-17

1-18

1-19

1-19

1-19

1-10

1-12

1-13

1-14

1-15

1-16

1-16

1-16

1-20

1-20

1-20

1-21

1-22

1-22

1-22

1-22

1-23

iv User's Guide

Connecting to the Server via the Web

Microsoft Windows Domain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Linux Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installing Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 3. Managing Domains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Introducing PAM Domain Management Tools

Managing Domain Configuration Schemes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Synchronizing NovaScale 5xx5 SMP Server Domains

Viewing a Domain Configuration Scheme

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Loading a Domain Configuration Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adding Domains to the Current Domain Configuration . . . . . . . . . . . . . . . . . . . . . .

Replacing the Current Domain Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Saving the Current Domain Configuration Snapshot . . . . . . . . . . . . . . . . . . . . . . . .

Powering On a Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Powering On a Single Domain

Powering On Multiple Domains

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Powering Off a Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Powering Off a Single Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Powering Off Multiple Domains

Forcing a Domain Power Off

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Forcibly Powering Off a Single Domain

Forcibly Powering Off Multiple Domains

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Performing a Domain Memory Dump

Manually Resetting a Domain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deleting a Domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing a Domain Fault List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain Functional Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain Power Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain Powering Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain BIOS Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain Request Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain Configuration, Resources and Status

Viewing Domain Configuration

. . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Domain Hardware Resources

Viewing Domain Details and Status

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

What To Do if an Incident Occurs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dealing with Incidents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 4. Monitoring the Server

Introducing PAM Monitoring Tools

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing System / Component Status

PAM Status Pane

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CSS Availability Status

System Functional Status

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Event Message Status

PAM Tree Pane

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Displaying Presence Status

Displaying Functional Status

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using PAM Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using the Hardware Search Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing PAM Web Site User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing PAM Version Information

Viewing Server Hardware Status

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-20

2-20

2-20

2-21

3-24

3-25

3-26

3-28

3-29

3-31

3-32

3-14

3-15

3-18

3-18

3-19

3-21

3-22

3-22

3-33

3-34

3-35

3-35

3-38

3-38

3-42

3-43

3-1

3-2

3-5

3-6

3-6

3-8

3-10

3-10

3-11

3-14

4-4

4-5

4-5

4-7

4-10

4-10

4-12

4-13

4-14

4-1

4-2

4-3

4-3

4-4

4-4

Preface v

Viewing Detailed Hardware Information

General Tab

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FRU Info Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Firmware Tab (Core MFL & PMB only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thermal Zones (CSS module only)

Power Tab

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CSS Module Power Tab

Temperature Tab

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fan Status (Fanboxes only)

Jumper Status (IOC only)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PCI Slots (IOC only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Excluding / Including Hardware Elements

Excluding a Hardware Element

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Including a Hardware Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Excluding / Including Clocks, SPS, XSP Cables and Sidebands . . . . . . . . . . . . . . . . .

Excluding / Including Clocks

Excluding / Including SPS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Excluding / Including XSP Cables

Excluding / Including Sidebands

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Managing PAM Messages, Histories, Archives and Fault Lists

Understanding PAM Message Severity Levels

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing PAM Messages and Fault Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing and Acknowledging PAM Web Event Messages

Sorting and Locating Messages

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing E-mailed Event Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Hardware / Domain Fault Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing, Archiving and Deleting History Files

Viewing History Files Online

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing History Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Manually Archiving History Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing Archive Files Online

Viewing Archive Properties

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Manually Deleting a History Archive File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Downloading History / Archive Files for Offline Viewing

Downloading History Viewer

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Downloading History / Archive Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viewing History / Archive Files Offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

What to Do if an Incident Occurs

Investigating Incidents

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dealing with Incidents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking Hardware Availability

Checking Hardware Connections

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Excluding a Hardware Element and Checking Exclusion Status . . . . . . . . . . . . . . .

Checking Hardware Fault Status

Checking Hardware Power Status

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking Hardware Temperature Status

Checking Histories and Events

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking SNMP Settings

Checking Autocall Settings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking PAM Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking MAESTRO Version

Checking Writing Rules

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Powering OFF/ON a Domain

Rebooting the PAP Application

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-47

4-47

4-47

4-47

4-48

4-48

4-48

4-48

4-48

4-48

4-48

4-42

4-42

4-46

4-46

4-46

4-47

4-47

4-38

4-39

4-40

4-40

4-40

4-40

4-41

4-34

4-35

4-35

4-35

4-36

4-36

4-37

4-38

4-27

4-28

4-29

4-30

4-31

4-32

4-33

4-21

4-21

4-22

4-23

4-23

4-24

4-27

4-15

4-15

4-16

4-17

4-17

4-18

4-19

4-20

vi User's Guide

Modifying LUN Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking, Testing and Resetting the PMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PMB LEDs and Code Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating an Action Request Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating a Default Action Request Package

Creating a Filtered Action Request Package

Creating a Custom Package

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chapter 5. Tips and Features for Administrators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting up Server Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Configuring System and Data Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating New FC Logical System or Data Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using the EFI Boot Manager

EFI Boot Manager Options

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using the EFI Shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Entering the EFI Shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EFI Shell Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Variable Substitution

Wildcard Expansion

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Output Redirection

Quoting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Executing Batch Scripts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Error Handling in Batch Scripts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Comments in Script Files

EFI Shell Commands

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EFI Network Setup and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Manual EFI Network Configuration

File Transfer Protocol (FTP)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting up PAP Unit Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Predefined PAP User Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Modifying Customer Information

Configuring Autocalls

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting Thermal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deploying a PAM Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Activating a PAM Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Backing Up and Restoring PAM Configuration Files . . . . . . . . . . . . . . . . . . . . . . . . . . .

Backing Up PAM Configuration Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Restoring PAM Configuration Data

Partitioning your Server

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assessing Configuration Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Managing Domain Configuration Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating a Domain Configuration Scheme

Editing a Domain Configuration Scheme

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Copying a Domain Configuration Scheme

Deleting a Domain Configuration Scheme

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Renaming a Domain Configuration Scheme

Updating Default Schemes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating, Editing, Copying, Deleting a Domain Identity . . . . . . . . . . . . . . . . . . . . . . . .

Creating a Domain Identity

Editing a Domain Identity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Copying a Domain Identity

Deleting a Domain Identity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Managing Logical Units (Servers Not Connected to a SAN)

Updating the Local LUN Lists

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Clearing, Loading, Saving NVRAM Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5-33

5-48

5-49

5-49

5-49

5-49

5-50

5-24

5-26

5-26

5-27

5-29

5-31

5-33

5-50

5-54

5-54

5-54

5-55

5-56

5-56

5-14

5-15

5-17

5-17

5-19

5-20

5-22

5-23

5-10

5-11

5-11

5-11

5-11

5-11

5-14

5-7

5-7

5-9

5-9

5-9

5-10

5-10

5-1

5-4

5-5

5-5

4-49

4-49

4-50

4-51

4-51

4-53

4-54

Preface vii

Managing Logical Units (Servers Connected to a SAN)

Updating SAN LUN Lists

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Declaring Local LUNs

Deleting Local LUNs

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Editing LUNs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Renaming LUNs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Clearing, Loading, Saving NVRAM Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking and Updating Fibre Channel HBA World Wide Names . . . . . . . . . . . . . . .

Limiting Access to Hardware Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Locking / Unlocking Hardware Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating a Mono-Domain Scheme Using All Server Resources . . . . . . . . . . . . . . . . . .

Creating a Mono-Domain Scheme Using a Selection of Server Resources

Creating a Multi-Domain Scheme Using All Server Resources

. . . . . . . .

. . . . . . . . . . . . . . . . . . .

Creating a Multi-Domain Scheme Using a Selection of Server Resources

Configuring and Managing Extended Systems

. . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scheme, Domain Identity, and Resources Checklists

Customizing the PAM Event Messaging System

. . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting up Event Subscriptions

Event Subscription Flowcharts

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating, Editing, Deleting an E-mail Server

Creating an E-mail Server

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Editing E-mail Server Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deleting an E-mail Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating, Editing, Deleting an E-mail Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating an E-mail Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Editing E-mail Account Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deleting an E-mail Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Enabling / Disabling Event Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating, Editing, Deleting an Event Subscription

Creating an Event Subscription

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Editing Event Subscription Attributes

Deleting an Event Subscription

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Understanding Event Message Filtering Criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Standard Event Message Filtering Criteria

Advanced Event Message Filtering Criteria

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preselecting, Creating, Editing, Deleting an Event Filter

Preselecting an Event Filter

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating an Event Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Editing Event Filter Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deleting an Event Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating, Editing, Deleting a User History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Creating a User History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Editing History Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deleting a User History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix A. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NovaScale 5085 Server Specifications

NovaScale 5165 Server Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NovaScale 5245 Server Specifications

NovaScale 5325 Server Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5-126

5-133

5-134

5-135

5-136

5-136

5-137

5-137

5-138

5-138

5-139

5-139

5-140

5-141

5-141

5-66

5-67

5-69

5-83

5-96

5-111

5-125

5-57

5-59

5-60

5-61

5-62

5-63

5-63

5-64

5-142

5-142

5-143

5-145

5-148

5-153

5-153

5-154

5-155

5-155

5-156

5-157

5-158

5-159

A-1

A-2

A-4

A-6

A-8

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

G-1

viii User's Guide

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

X-1

Preface ix

x User's Guide

List of Figures

Figure 1.

AZERTY keyboard

Figure 2.

QWERTY keyboard

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 3.

Bull NovaScale Server cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 4.

NovaScale 5085 Partitioned Server components - example

Figure 5.

NovaScale 5165 Partitioned Server components - example

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . .

Figure 6.

NovaScale 5245 Partitioned Server components - example . . . . . . . . . . . . . . . . . . . . . . . .

Figure 7.

NovaScale 5325 Partitioned Servers components - example

Figure 8.

NovaScale 5325 Partitioned Servers components - example

Figure 9.

CSS module features (full CSS module example)

. . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 10. PAP unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 11. Integrated console features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 12. 8-port KVM switch features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 13. 16-port KVM switch features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 14. KVM extender (local & remote) 300m maxi.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 15. FDA 1x00 FC disk rack features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 16. FDA 2x00 FC disk rack features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 17. FDA 1x00 FC extension disk rack features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 18. Ethernet hub features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 19. USB modem features

Figure 20. NPort Server features

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 21. Opening the front door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 22. Integrated console example

Figure 23. PAM software deployment

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 24. PAM Web site session details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 25. Multiple session example

Figure 26. PAM user interface

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 27. Status pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 28. CSS Module availability status bar (bi-module server)

Figure 29. PAM Tree toolbar

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 30. Domain Manager Control pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 31. Domain state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 32. Domain schemes list dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 33. Domain Manager Control pane - example with 4 domains

Figure 34. Multiple power dialog - example with 4 domains

. . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 35. Domain state - example with 4 domains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 36. Schemes list dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 37. Scheme properties dialog - Example with 4 domains

Figure 38. Schemes list dialog

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 39. Domain Manager control pane - Example with 4 domains . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 40. Domain Infotip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 41. Save Snapshot dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 42. Multiple power dialog - quadri-domain example

Figure 43. Multiple power dialog - quadri-domain example

Figure 44. Multiple power dialog - quadri-domain example

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 45. Delete domain dialog - mono-module server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 46. Delete Domain dialog - Example with 4 domains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-11

2-13

2-13

2-14

2-14

3-7

2-4

2-5

2-6

2-7

2-8

2-10

3-7

3-8

3-9

3-9

3-11

3-16

3-19

3-23

3-26

3-26

1-19

1-19

1-20

1-21

1-22

2-4

1-16

1-16

1-17

1-17

1-18

1-19

1-10

1-11

1-13

1-14

1-15

1-16

xxii xxii

1-2

1-7

1-8

1-9

Preface xi

Figure 47. Domain deleted information box

Figure 48. Domain fault list dialog - example

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 49. Power logs dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 50. Powering view dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 51. BIOS Info dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 52. Request Logs dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 53. View Domain dialog - example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 54. View Domain dialog 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 55. View Domain dialog 2/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 56. Domain Hardware Resources dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 57. Domain Hardware Details dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 58. PAM Status pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 59. CSS Module availability status bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 60. PAM Tree hardware presence status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 61. PAM Tree functional status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 62. PAM Tree - automatically expanded functional status display . . . . . . . . . . . . . . . . . . . . . . .

Figure 63. Hardware Search engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 64. Hardware Search result list (example)

Figure 65. PAM Web Site user information

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 66. PAP unit information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 67. PAM Hardware Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 68. General Hardware Status page (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 69. FRU data (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 70. Firmware data (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 71. CSS module thermal zone details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 72. Converter power status details (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 73. CSS module power status details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 74. Temperature probe status details (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 75. Fanbox details (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 76. IO Box jumpers tab

Figure 77. PCI slot status

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 78. PCI slot details dialog (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 79. Inclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 80. Example Hardware Status page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 81. Ring exlcusion control pane - clock tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 82. Ring exclusion control pane - SPS tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 83. Ring exclusion control pane - XSP cable tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 84. Ring exclusion control pane - sideband tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 85. Display Events page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 86. Specimen message help file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 87. History Manager Control pane - Histories tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 88. History properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 89. History Manager Control pane - Archived histories tab . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 90. Archive properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 91. PMB LED location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 92. Action Request Package control pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 93. Action Request Package details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 94. Custom Package control pane

Figure 95. Custom Package Add files pane

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-33

4-34

4-36

4-37

4-38

4-39

4-50

4-51

4-53

4-54

4-55

4-23

4-24

4-27

4-28

4-29

4-30

4-19

4-20

4-21

4-21

4-22

4-22

4-14

4-15

4-16

4-17

4-17

4-18

4-7

4-9

4-10

4-11

4-12

4-13

3-37

3-38

3-39

4-3

4-4

4-5

3-27

3-28

3-31

3-32

3-33

3-34

3-35

3-36

xii User's Guide

Figure 96. Customer Information configuration page

Figure 97. Autocalls Channel Settings control pane

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 98. PAM configuration control pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 99. PAM Installation InstallShield Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 100. PAM Activation InstallShield Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 101. Schemes and Identites panes

Figure 102. Schemes control pane

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 103. Scheme Management dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 104. Scheme Creation and Central Subsystem Configuration dialogs

Figure 105. Optimizing partitioning

. . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 106. Scheme Management dialog - Central Subsystem configured . . . . . . . . . . . . . . . . . . . . . .

Figure 107. Domain Identities list

Figure 108. EFI LUN selection list

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 109. Select Data LUN dialog - Data luns available list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 110. View LUN parameters dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 111. Select Data LUN dialog - Data luns selected list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 112. Link LUNs to HBA dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 113. Select an HBA dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 114. Scheme Management dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 115. Edit Scheme dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 116. Identities List page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 117. Create New Identity dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 118. Advanced Identity Settings dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 119. Logical Units page - servers not connected to a SAN

Figure 120. Logical Units page - servers connected to a SAN

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 121. SAN Update progress bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 122. Declare Local LUN dialog

Figure 123. Delete LUN dialog

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 124. Edit LUN dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 125. Rename LUN dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 126. HBA Worldwide Name page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 127. Modify PCI HBA Worldwide Name dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 128. Lock domain hardware resources dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 129. Lock domain hardware resources dialog - PCI slot selected . . . . . . . . . . . . . . . . . . . . . . . .

Figure 130. Scheme creation dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 131. Central Subsystem configuration dialog - example 1

Figure 132. Scheme Management dialog - example 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 133. Identity list dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 134. Create new identity dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 135. Create new identity advanced setting dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 136. Select EFI LUN dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 137. Select Data LUN dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 138. Link LUN to HBA dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 139. Select HBA dialog - example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 140. Scheme creation dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 141. Central Subsystem configuration dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 142. Scheme Management dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 143. Identity list dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 144. Create new identity advanced setting dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . .

5-78

5-79

5-79

5-80

5-81

5-81

5-87

5-89

5-91

5-92

5-92

5-67

5-68

5-73

5-75

5-77

5-78

5-60

5-61

5-62

5-63

5-64

5-65

5-50

5-51

5-52

5-55

5-58

5-59

5-43

5-44

5-44

5-45

5-47

5-48

5-37

5-38

5-40

5-40

5-41

5-42

5-19

5-20

5-22

5-23

5-24

5-30

5-34

5-35

Preface xiii

Figure 145. Create new identity advanced setting dialog - example 2

Figure 146. Select EFI LUN dialog - example 2

. . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 147. Select Data LUN dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 148. Link LUN to HBA dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 149. Select HBA dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 150. Scheme creation dialog - example 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 151. Central Subsystem configuration dialog - example 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 152. Scheme Management dialog - example 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 153. Identities list dialog - example 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 154. Create new identity dialog - example 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 155. Create new identity advanced setting dialog - example 3 . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 156. Select SAN EFI LUN dialog - example 3

Figure 157. Select Local EFI LUN dialog - example 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 158. Select Data LUN dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 159. Link LUN to HBA dialog - example 3

Figure 160. Select HBA dialog - example 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 161. Scheme creation dialog - example 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 162. Central Subsystem configuration dialog - example 4

Figure 163. Scheme Management dialog - example 4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 164. Identities list dialog - example 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 165. Create new identity dialog - example4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 166. Create new identity advanced setting dialog - example 4 . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 167. Select EFI LUN dialog - example 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 168. Select Data LUN dialog - example 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 169. Link LUN to HBA dialog - example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 170. Select HBA dialog - example 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 171. Lock domain hardware resources - example 4

Figure 172. PAM event messaging system features

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 173. E-mail servers configuration page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 174. E-mail accounts configuration page

Figure 175. Event Channels configuration page

Figure 176. New Event Subscription dialog box

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 177. Event message standard filtering criteria chart

Figure 178. Event message advanced filtering criteria chart

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 179. Filters configuration page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 180. New Filter configuration page - standard event message filtering criteria table

Figure 181. New Filter configuration page - advanced event message filtering criteria table

. . . . . . .

. . . . . .

Figure 182. Create a New User History dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5-110

5-110

5-115

5-117

5-119

5-120

5-120

5-121

5-121

5-122

5-123

5-123

5-93

5-93

5-94

5-95

5-95

5-101

5-103

5-106

5-106

5-107

5-107

5-108

5-108

5-109

5-124

5-133

5-136

5-138

5-140

5-141

5-143

5-144

5-153

5-154

5-155

5-157

xiv User's Guide

List of Tables

Table 1.

PAM illegal characters

Table 2.

String length rules

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 3.

PAM Tree nodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 4.

KVM port configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 5.

PAM Domain Manager tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 6.

MyOperations Scheme organization - NovaScale 5xx5 Partitioned Servers . . . . . . . . . .

Table 7.

Power-on states

Table 8.

Power-on states

Table 9.

Power-off states

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 10.

Power-off states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 11.

Force power-off states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 12.

Power-off states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 13.

Dump states

Table 14.

Reset states

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 15.

Domain functional status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 16.

Domain hardware details icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 17.

Domain power sequence error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 18.

CSS hardware functional status icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 19.

Hardware presence status indicators

Table 20.

Hardware functional status indicators

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 21.

Fault status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 22.

Power tab status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 23.

Temperature tab status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 24.

Hardware exclusion guidelines - 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 25.

Hardware exclusion guidelines

Table 26.

Message severity levels

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 27.

CSS functional status / domain state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 28.

NovaScale SMP server domain cell resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 29.

NovaScale partitioned server domain cell resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 30.

Boot Option Maintenance Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 31.

Wildcard character expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 32.

Output redirection syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 33.

List of EFI Shell Commands

Table 34.

User access to PAM features

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 35.

Domain configuration assessment criteria - 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 36.

Domain configuration assessment criteria - 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 37.

Hardware locking options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 38.

Scheme configuration criteria - example 1 - mono-module server . . . . . . . . . . . . . . . . . . .

Table 39.

Scheme configuration criteria - example 1 - 2 modules server

Table 40.

Scheme configuration criteria - example 1 - 3 modules server

Table 41.

Scheme configuration criteria - example 1 - 4 modules server

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

Table 42.

Scheme configuration criteria - example 2 - mono-module server

Table 43.

Scheme configuration criteria - example 2 - bi-module server

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

Table 44.

Scheme configuration criteria - example 2 - 3 modules server . . . . . . . . . . . . . . . . . . . . . .

Table 45.

Scheme configuration criteria - example 2 - 4 modules server . . . . . . . . . . . . . . . . . . . . . .

Table 46.

Scheme configuration criteria - example 3 - mono-module server . . . . . . . . . . . . . . . . . . .

5-10

5-10

5-13

5-18

5-31

5-32

4-26

4-32

4-43

4-44

4-45

5-8

5-66

5-69

5-70

5-71

5-72

5-83

5-84

5-85

5-86

5-97

4-6

4-8

4-16

4-18

4-20

4-25

3-24

3-25

3-30

3-40

3-42

4-4

3-15

3-17

3-18

3-20

3-22

3-23

xx

xxi

2-7

2-9

3-4

3-13

Preface xv

Table 47.

Scheme configuration criteria - example 3 - bi-module server . . . . . . . . . . . . . . . . . . . . . . .

Table 48.

Scheme configuration criteria - example 3 - 3 modules server . . . . . . . . . . . . . . . . . . . . . .

Table 49.

Scheme configuration criteria - example 3 - 4 modules server

Table 50.

Scheme configuration criteria - example 4 - bi-module server

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

Table 51.

Scheme configuration criteria - example 4 - 3 modules server . . . . . . . . . . . . . . . . . . . . . .

Table 52.

Scheme configuration criteria - example 4 - 4 modules server

Table 53.

Scheme configuration checklist

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 54.

Domain Identity configuration checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 55.

Resources checklist - part 1

Table 56.

Resources checklist - part 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 57.

Resources checklist - part 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 58.

Resources checklist - part 4

Table 59.

Event channels

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 60.

Event channel selection guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 61.

Standard event message filtering criteria

Table 62.

Advanced event message filtering criteria

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 63.

System history contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 64.

History automatic achiving policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 65.

NovaScale 5085 Server specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 66.

NovaScale 5165 Server specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 67.

NovaScale 5245 Server specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Table 68.

NovaScale 5325 Server specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5-98

5-99

5-100

5-112

5-113

5-114

5-126

5-127

5-128

5-129

5-130

5-131

5-134

5-140

5-147

5-152

5-156

5-158

A-3

A-5

A-7

A-9

xvi User's Guide

Intended Readers

This guide is intended for use by the Administrators and Operators of NovaScale 5xx5

Servers.

It will also prove useful to the Administrators and Operators of Bull NovaScale 7000 Series and Bull NovaScale 9000 Series servers.

Chapter 1. Introducing the Server describes server hardware components and user environment.

Chapter 2. Getting Started explains how to connect to and use the server.

Chapter 3. Managing Domains describes how to perform straightforward server domain management tasks.

Chapter 4. Monitoring the Server explains how to supervise server operation.

Chapter 5. Tips and Features for Administrators explains how, as Customer Administrator, you can configure the server to suit your environment.

Appendix A. Specifications

Highlighting

The following highlighting conventions are used in this guide:

Bold

Italics

< >

Identifies predefined commands, subroutines, keywords, files, structures, buttons, labels, and icons.

Identifies referenced publications, chapters, sections, figures, and tables.

Identifies parameters to be supplied by the user.

Abbreviations, acronyms and concepts are documented in the Glossary.

Related Publications

Site Preparation Guide, 86 A1 87EF explains how to prepare a Data Processing Center for Bull NovaScale Servers, in compliance with the standards in force. This guide is intended for use by all personnel and trade representatives involved in the site preparation process.

Installation Guide, 86 A1 40EM explains how to set up and start NovaScale 5xx5 Servers for the first time. This guide is intended for use by qualified support personnel.

Cabling Guide, 86 A192ER describes server cabling.

Bull 1300H/L & 1100H/L Cabinets, 86 A1 91EM explains how to install and fit out rack cabinets for Bull NovaScale Servers and peripheral devices.

Note:

According to server configuration and version, certain features and functions described in this guide may not be accessible. Please contact your Bull Sales Representative for sales information.

Preface xvii

Regulatory Specifications and Disclaimers

Declaration of the Manufacturer or Importer

We hereby certify that this product is in compliance with European Union EMC Directive

2004/108/CE, using standards EN55022 (Class A) and EN55024 and Low Voltage

Directive 2006/95/CE, using standard EN60950. The product has been marked with the

CE Mark to illustrate its compliance.

Safety Compliance Statement

• UL 60950 (USA)

• IEC 60950 (International)

• CSA 60950 (Canada)

European Community (EC) Council Directives

This product is in conformity with the protection requirements of the following EC Council

Directives:

Electromagnetic Compatibility

• 2004/108/CE

Low Voltage

• 2006/95/CE

EC Conformity

• 93/68/EEC

Telecommunications Terminal Equipment

• 1999/5/EC

Neither the provider nor the manufacturer can accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product.

Compliance with these directives requires:

• an EC declaration of conformity from the manufacturer

• an EC label on the product

• technical documentation xviii User's Guide

Federal Communications Commission (FCC) Statement

Note:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Neither the provider nor the manufacturer are responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment.

Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product.

FCC Declaration of Conformity

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Canadian Compliance Statement (Industry Canada)

This Class A digital apparatus meets all requirements of the Canadian Interference Causing

Equipment Regulations.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

This product is in conformity with the protection requirements of the following standards:

Electromagnetic Compatibility

• ICES-003

• NMB-003

Laser Compliance Notice

This product that uses laser technology complies with Class 1 laser requirements.

A CLASS 1 LASER PRODUCT label is located on the laser device.

Class 1 Laser Product

Luokan 1 Laserlaite

Klasse 1 Laser Apparat

Laser Klasse 1

Preface xix

Definition of Safety Notices

DANGER

A Danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury.

CAUTION:

A Caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury.

Warning:

A Warning notice indicates an action that could cause damage to a program, device, system, or data.

Electrical Safety

The following safety instructions shall be observed when connecting or disconnecting devices to the system.

DANGER

The Customer is responsible for ensuring that the AC electricity supply is compliant with national and local recommendations, regulations, standards and codes of practice.

An incorrectly wired and grounded electrical outlet may place hazardous voltage on metal parts of the system or the devices that attach to the system and result in an electrical shock.

It is mandatory to remove power cables from electrical outlets before relocating the system.

CAUTION:

This unit has more than one power supply cable. Follow procedures for removal of power from the system when directed.

xx User's Guide

Laser Safety Information

The optical drive in this system unit is classified as a Class 1 level Laser product. The optical drive has a label that identifies its classification.

The optical drive in this system unit is certified in the U.S. to conform to the requirements of the Department of Health and Human Services 21 Code of Federal Regulations (DHHS 21

CFR) Subchapter J for Class 1 laser products. Elsewhere, the drive is certified to conform to the requirements of the International Electrotechnical Commission (IEC) 60825-1: 2001 and

CENELEC EN 60825-1: 1994 for Class 1 laser products.

CAUTION:

Invisible laser radiation when open. Do not stare into beam or view directly with optical instruments.

Class 1 Laser products are not considered to be hazardous. The optical drive contains internally a Class 3B gallium-arsenide laser that is nominally 30 milliwatts at 830 nanometers. The design incorporates a combination of enclosures, electronics, and redundant interlocks such that there is no exposure to laser radiation above a Class 1 level during normal operation, user maintenance, or servicing conditions.

Data Integrity and Verification

Warning:

Bull NovaScale Servers are designed to reduce the risk of undetected data corruption or loss.

However, if unplanned outages or system failures occur, users are strongly advised to check the accuracy of the operations performed and the data saved or transmitted by the system at the time of outage or failure.

Waste Management

This product has been built to comply with the Restriction of Certain Hazardous Substances

(RoHS) Directive 2002/95/EC.

This product has been built to comply with the Waste Electrical and Electronic (WEEE)

Directive 2002/96/EC.

Preface xxi

PAM Writing Rules

Illegal Characters

The following table lists the illegal characters that must not be used in PAM identifiers.

I

,

~

;

?

:

!

=

<

>

*

%

&

+

'

`

\

"

à, é, è, ù, ^, ¨

/

Illegal Characters

Accentuated letters

Slash

Backslash

Double quote

Simple quote

Inverted comma

Ampersand

Plus

Asterisk

Percent

Equal sign

Less-than sign

Greater-than sign

Colon

Exclamation mark

Question mark

Semi-colon

Comma

Tilde

Pipe operator

Space. Use - (dash) or _ (underscore)

Table 1.

PAM illegal characters xxii User's Guide

String Lengths

The following table lists authorized string lengths.

String Type

CellBlock / System Name

Scheme Name

History Name

Archive Name

LUN Name

Switch Name

Event Name

Description

Domain Identity Name

Table 2.

String length rules

Length

16

32

64

75 (History Name: + 11

(_JJMMAA_nnn)

32

32

32

256 (Scheme: unlimited)

16

Registry Keys

PAM obtains file paths via 2 registry keys:

• ReleaseRoot:

Contains PAP application file paths (DLL, WEB pages, models,...).

Two versions of PAM software can be installed and used indifferently on the same machine: each new version is installed in a new directory.

• SiteRoot:

Contains site data file paths.

Site data remains valid when the PAM software version changes.

Registry keys are generally stored under: HKEY_LOCAL_MACHINE\SOFTWARE\BULL\PAM

Preface xxiii

AZERTY/QWERTY Keyboard Lookup Table

Figure 1.

AZERTY keyboard

Figure 2.

QWERTY keyboard xxiv User's Guide

Administrator's Memorandum

Domains

Manage Domain Schemes, on page 3-5

Synchronize NovaScale 5xx5 SMP Server Domains, on page 3-6

Power ON a Domain, on page 3-14

Power OFF a Domain, on page 3-18

Perform a Manual Domain Reset, on page 3-25

Perform a Domain Force Power OFF, on page 3-21

Perform a Domain Memory Dump, on page 3-24

View Domain Functional Status, on page 3-29

View Domain Power Logs, on page 3-31

View Domain Powering Sequences, on page 3-32

View Domain BIOS Info, on page 3-33

View Domain Request Logs, on page 3-34

View Domain Configuration, Resources and Status, on page 3-35

Solve Incidents, on page 3-42

* Reserved for partitioned servers and extended systems.

Monitoring

Refresh the PAM Display, on page 4-2

View CSS Availability Status and System Functional Status, on page 4-4

View Event Message Status, on page 4-4

Display Hardware Presence / Functional Status, on page 4-5

View PAM Web Site User Information, on page 4-12

View PAM Version Information, on page 4-13

View Server Hardware Status, on page 4-14

Use the Hardware Search Engine, on page 4-10

Display Detailed Hardware Information, on page 4-15

Exclude / Include Hardware Elements, on page 4-23

Exclude / Include Clocks, SPS, XSP Links and Sidebands, on page 4-27

Manage PAM Event Messages, History Files, Archives, Fault Lists, on page 4-31

Understand Message Severity Levels, on page 4-32

View, Acknowledge WEB Event Messages, on page 4-34

Sort and Locate Messages, on page 4-35

Solve Incidents, on page 4-42

Create an Action Request Package, on page 4-51

Create a Custom Package, on page 4-54

Preface xxv

xxvi User's Guide

Configuration

Set up Server Users, on page 5-4

Configure System and Data Disks, on page 5-5

Use the EFI Boot Manager, on page 5-7

Use the EFI Shell, on page 5-9

Set Up and Configure the EFI Network, on page 5-14

Set up PAP Unit Users, on page 5-17

Modify Customer Information, on page 5-17

Configure PAM Autocall Parameters, on page 5-20

Customize PAM Settings, on page 5-22

Deploy a New PAM Release, on page 5-23

Activate a PAM Version, on page 5-24

Back Up and Restore PAM Configuration Files, on page 5-26

• Configure Domains, on page 5-28*

• Assess Configuration Requirements, on page 5-31*

• Create, Edit, Copy, Delete, Rename a Domain Scheme, on page 5-33*

• Update DefaultSchemes, on page 5-49*

• Create, Edit, Copy, Delete a Domain Identity, on page 5-50*

Manage LUNs (Servers Not Connected to a SAN), on page 5-57

Manage LUNs (Servers Connected to a SAN), on page 5-55

Check and Update Fibre Channel HBA World Wide Names, on page 5-64

Limit Access to Hardware Resources, on page 5-66

• Configure Extended Systems, on page 5-125*

• Prepare Scheme, Domain Identity and Resources Checklists, on page 5-126*

Customize the PAM Event Messaging System, on page 5-133

Set up Event Subscriptions, on page 5-134

Event Subscription Flowcharts, on page 5-134

Create, Edit, Delete an E-mail Server, on page 5-136

Create, Edit, Delete an E-mail Account, on page 5-138

Create, Edit, Delete a User History, on page 5-157

Enable / Disable Event Channels, on page 5-140

Create, Edit, Delete an Event Subscription, on page 5-141

Understand Event Message Filtering Criteria, on page 5-143

Preselect an Event Filter, on page 5-153

Create, Edit, Delet an Event Filter, on page 5-154

Excluding / Including Clocks, SPS, XSP Links and Sidebands, on page 4-27

* Reserved for partitioned servers and extended systems.

Operator's Memorandum

Domains

Synchronize NovaScale 5xx5 SMP Server Domains, on page 3-6

Power ON a Domain, on page 3-14

Power OFF a Domain, on page 3-18

Perform a Domain Force Power OFF, on page 3-21

Perform a Manual Domain Reset, on page 3-25

Perform a Domain Memory Dump, on page 3-24

View Domain Functional Status, on page 3-29

View Power Logs, on page 3-31

View Domain Powering Sequences, on page 3-32

View BIOS Info, on page 3-33

View Domain Request Logs, on page 3-34

View Domain Configuration, Resources and Status, on page 3-35

Solve Incidents, on page 3-42

Histories

Manage PAM Event Messages, History Files, Archives, Fault Lists, on page 4-31

Understand Event Message and History Severity Levels, on page 4-32

Sort and Locate messages, on page 4-35

Status

Check System Functional Status, on page 4-4

Check CSS Availability, on page 4-4

View, Acknowledge WEB Event Messages, on page 4-34

Sort, Locate WEB event messages, on page 4-35

Preface xxvii

Chapter 1. Introducing the Server

This chapter describes the main hardware components and user environment for NovaScale

5xx5 Servers. It includes the following topics:

Bull NovaScale Server Overview, on page 1-2

Accessing Server Components, on page 1-20

Bull NovaScale Server Resources, on page 1-22

PAM Software Package, on page 1-22

EFI Utilities, on page 1-23

Note:

Customer Administrators and Customer Operators are respectively advised to consult the

Administrator's Memorandum, on page xxv or the Operator's Memorandum, on page xxvii

for a detailed summary of the everyday tasks they will perform.

Introducing the Server 1-1

Bull Novascale Server Overview

Bull NovaScale Servers for business and scientific applications are based upon the FAME architecture (Flexible Architecture for Multiple Environments), leveraging the latest generation of Intel Itanium 2 processors.

Servers are designed to operate as one to eight hardware-independent SMP systems or domains, each running an Operating System instance and a specific set of applications.

According to version, servers are delivered rack-mounted and ready-to-use in high or low cabinets.

Figure 3.

Bull NovaScale Server cabinets

Dynamic Partitioning

Bull NovaScale Servers can be dynamically partitioned into physically independent ccNUMA

(Cache Coherent Non Uniform Memory Access) SMP systems or domains, each running an

Operating System instance and a specific set of applications.

Extended Configurations

Several Bull NovaScale Servers may be administered through a single instance of PAM software.

Cluster Configurations

Several Bull NovaScale Servers may be grouped to act like a single system, enabling high availability, load balancing and parallel processing.

1-2 User's Guide

Server Features

The main features of Bull NovaScale Servers are:

Intel Itanium Processor Family architecture:

- Modularity, predictable performance and growth

High availability:

- Component redundancy

- Capacity to isolate or replace a faulty component without service disruption

- Global and unified system visibility

- Round-the-clock operation

Scalability:

- Dynamic partitioning

- Power on demand: capacity to dynamically adapt resources and processor frequency to load requirement

Simultaneous support of multiple environments:

- Microsoft Windows Server

- Linux

High performance computing capabilites:

- Technical and scientific applications:

. High Performance Computing (HPC)

- Business Intelligence:

. Datawarehousing

. Datamining

- Large enterprise applications:

. ERP

. CRM

. SCM ...

- Large database applications for Internet transactions.

- Large business sector applications:

. Online billing

. Online reservations

. Online banking ...

Built-in Platform Administration and Maintenance (PAM) software suite:

- Proactive administration

- Optimization of resources

- Automatic generation of corrective actions and calls to support centers

- Dynamic configuration

Bull NovaScale Master System Management (NSM) software suite:

- Windows, Linux, and Platform management

- Monitoring, Information, Control, and Event Handling

- Client / Server / Agent architecture

- WEB standard OpenSource solutions

Introducing the Server 1-3

Server Hardware

Note:

Abbreviations and acronyms are documented in the Glossary.

Main server hardware components are:

Central SubSystem Module (CSS Module)

Main server hardware components are housed in the CSS Module. For easy access and servicing, the CSS Module is composed of three interconnected units:

Front Unit

1 or 2

QBBs

1 or 2

Internal Peripheral Drawers

1 MQB

Core Unit

1 MIO

2 MSXs

1 MFL

8 Fanboxes

Rear Unit

1 or 2

IOCs

1 or 2

IOLs

1

PMB

2 or 4

DPS Units

Notes:

• The CSS Module can be logically divided into two Cells, each with one QBB and one

IOC, to allow dynamic partitioning.

• According to version, servers are equipped with one, two, three, or four interconnected

CSS modules.

Front Unit

Quad Brick Block (QBB)

The QBB is equipped with 2 to 4 Itanium

2 processors and 16 DDR DIMMs. The QBB communicates with the rest of the system the high-speed bidirectional link Scalability Port

Switches (SPS) located on the MSX.

Internal Peripheral Drawer (IPD)

The Internal Peripheral Drawer is equipped with a DVD/CD ROM drive and a USB port. The

Internal Peripheral Drawer is connected to the MQB in the Core Unit via a Device Interface

Board (DIB).

Optionally:

• the Internal Peripheral Drawer can house 2 SCSI Disks for OS partitions or storage,

• two Internal Peripheral Drawers, in the same CSS module, can be connected together to house 4 SCSI Disks for OS partitions or storage (Chained DIBs).

Core Unit

Midplane QBB Board (MQB)

The QBBs and the Internal Peripheral Drawers are connected to the MQB.

Midplane IO Board (MIO)

The IOCs and the PMB are connected to the MIO.

Midplane SPS & XPS Board (MSX)

Each MSX houses 1 high-speed directional link Scalability Port Switch (SPS) and is connected to both the MIO and the MQB. Each QBB and IOC communicates with the rest of the system through the SPS.

1-4 User's Guide

Midplane Fan & Logistics Board (MFL)

16 Fans and various logistics components are implemented on the MFL. The MFL is connected to both the MIO and the MQB.

Fanboxes

8 Fanboxes, each housing 2 fans, provide redundant cooling.

Rear Unit

IO board Compact (IOC)

The IOC provides 4 x PCI -X and 2 x PCI-Express buses and a PCI Hot Plug Board (HPB).

The IOC communicates with the rest of the system through the high-speed bidirectional link

Scalability Port Switches (SPS) located on the MSX.

IO board Legacy (IOL)

The IOL is an IOC daughter board providing legacy IO connections: 2 USB ports, 1 LAN port, 2 serial ports, and 1 video port.

Platform Maintenance Board (PMB)

The PMB concentrates logistics access and links the platform to the Platform Administration

Processor (PAP Unit) running Platform Administration and Maintenance (PAM) software.

Distributed Power Supply (DPS) Unit

Each DPS Unit supplies 48V AC/DC power to the server. The server is equipped with 2 or 4

DPS units for full redundancy.

Platform Administration Processor (PAP) Unit

The PAP Unit hosts all server administration software, in particular Platform Administration and Maintenance (PAM) software.

KVM Switch

The KVM Switch allows the use of a single keyboard, monitor and mouse for the local server domains and the local PAM console.

Console

The Console contains the keyboard, monitor and touch pad / mouse used for local access to the server domains and to the PAP Unit.

Disk Subsystem

If the disk slots in the Internal Peripheral Drawer are not used for OS disk partitions, a SCSI

RAID or FC disk subsystem is required.

Additional Peripherals

Additional peripherals such as disk subsystems, storage area networks, communication networks, archiving peripherals etc. can be connected to the server via PCI adapters located in the IOCs. Such peripherals may either be rack-mounted in the server cabinet (if free space is available) or in external cabinets.

Server Firmware and Software

Operating Systems (OS)

The server is certified for the following Operating Systems:

• Windows Server 2003, Enterprise Edition

• Windows Server 2003, Datacenter Edition

• Linux Red Hat Enterprise Linux Advanced Server

• Novell SUSE SLES 9

Introducing the Server 1-5

BIOS

The BIOS controls the server startup process, dynamic resource allocation (Domain reconfiguration, hot-plugging), and error handling. The BIOS also includes:

• The Extended Firmware Interface (EFI), which provides the OS with system services.

• The EFI Shell, an autonomous environment used to run Off-line Test & Diagnostic suites.

Platform Administration and Maintenance (PAM) suite

The PAM Web-based software suite is used to operate, monitor, and configure the server.

PAM can be accessed locally or remotely through Microsoft Internet Explorer or Mozilla browsers, under the protection of appropriate access rights. PAM provides the administration functions needed to manage and maintain the server:

• Domain configuration and resource allocation

• Alert or maintenance requests to the Customer Service Center

• Error logging …

Test & Diagnostics suites

The server is delivered with the following T & D suites:

• Online Test & Diagnostic suite

• Offline Test & Diagnostic suite

• Power-On Self-Test suite

NovaScale Master (NSM) Management suite

The NSM software suite allows you to monitor and manage NovaScale Windows and Linux systems.

Conformance to Standards

Intel

Bull NovaScale Servers conform to all Intel platform standards:

• ACPI (Advanced Configuration and Power Interface)

• IPMI (Intelligent Platform Management Interface)

• EFI (Extended Firmware Interface)

• SMBIOS (System Management BIOS)

• DIG64 (Developer Interface Guide for Intel

Itanium

Architecture)

Windows

Bull NovaScale Servers conform to the standards set out in the Windows Hardware Design

Guide.

1-6 User's Guide

Getting to Know the Server

NovaScale 5085 Partitioned Server

Note:

Server components and configuration may differ according to the version chosen.

The server is delivered rack-mounted and pre-cabled in a low or high cabinet, typically containing the following components:

XXXXXXXX Front XXXXXXXXXXXXXXXXXXXX Rear

1 CSS module with core unit, power supply and AC power cable, including:

2 IOL board - legacy ports

3 4xPCI-X & 2x PCI-Express slots

PMB board

2 or 4 DPS units

2xQBB subsets (1 to 4 CPUs each)

*Multicore CPU = Socket

8

9

4 DVD-ROM drive

5 2xInternal SCSI RAID disks

6 USB port

7

10* Slideaway console with monitor and keyboard

11 8-ports KVM switch

12 PAP unit with CD-ROM writer, FDD and 2 disks

13*

*

1 or 2 PDU(s) with AC power cable

1 U

1 U

1 U

14 1 optional FC disk

16 Free space for additional components

*

**

3 U

4 U

Slideaway console. For an external console, use a KVM extender kit (150m max.).

Redundant servers are connected to 2 PDUs and have 4 DPS units.

Figure 4.

NovaScale 5085 Partitioned Server components - example

Introducing the Server 1-7

NovaScale 5165 Partitioned Server

Note:

Server components and configuration may differ according to the version chosen.

The server is delivered rack-mounted and pre-cabled in a high cabinet, typically containing the following components:

XXXXXXXX Front XXXXXXXXXXXXXXXXXXXX Rear

CSS module with core unit, power supply and AC power cable, including:

2 IOL board - legacy ports

3 4xPCI-X & 2x PCI-Express slots

4 DVD-ROM drive

5 2xInternal SCSI RAID disks

PMB board

2 or 4 DPS units

2xQBB subsets (1 to 4 CPUs each)

*Multicore CPU = Socket

10* Slideaway console with monitor and keyboard

8

9

6 USB port

7

1 U

11 8-ports KVM switch

12 PAP unit with CD-ROM writer, FDD and 2 disks

13** 1 or 2 PDU(s) with AC power cable

14 2 FC disks (optional)

1 U

1 U

3 U x

2

16 Free space for additional components (SCSI or FC disks) 14 U

* Slideaway console. For an external console, use a KVM extender kit (150m max.).

** Redundant servers are connected to 2 PDUs and have 4 DPS units.

Figure 5.

NovaScale 5165 Partitioned Server components - example

1-8 User's Guide

NovaScale 5245 Partitioned Server

Note:

Server components and configuration may differ according to the version chosen.

The server is delivered rack-mounted and pre-cabled in a high cabinet, typically containing the following components:

XXXXXXXX Front XXXXXXXXXXXXXXXXXXXX Rear

1,

15,

CSS module with core unit, power supply and AC power cable, including:

2 IOL board - legacy ports

3 4xPCI-X & 2x PCI-Express slots

4 DVD-ROM drive

5 2xInternal SCSI RAID disks

6 USB port

PMB board

2 or 4 DPS units

2xQBB subsets (1 to 4 CPUs each)

*Multicore CPU = Socket

7

8

9

10* External console with monitor and keyboard

11 8-ports KVM switch

12 PAP unit with CD-ROM writer, FDD and 2 disks

13** 1 or 2 PDU(s) with AC power cable

14 2 FC disks

16 Free space for additional components (SCSI or FC disks)

18 KVM extender

* External console, use a KVM extender kit (150m max.).

** Redundant servers are connected to 2 PDUs and have 4 DPS units.

Figure 6.

NovaScale 5245 Partitioned Server components - example

8 U x

3

1 U

1 U

3 U x2

14 U

1 U

Introducing the Server 1-9

NovaScale 5325 Partitioned Server

Note:

Server components and configuration may differ according to the version chosen.

The server is delivered rack-mounted and pre-cabled in two high cabinets, typically containing the following components:

Main Cabinet

XXXXXXXX Front XXXXXXXXXXXXXXXXXXXX Rear

1,

15,

16,

17

CSS module with core unit, power supply and AC power cable, including:

2 IOL board - legacy ports

3 4xPCI-X & 2x PCI-Express slots

4 DVD-ROM drive

PMB board

2 or 4 DPS units

2xQBB subsets (1 to 4 CPUs each)

*Multicore CPU = Socket

8

9

5 2xInternal SCSI RAID disks

6 USB port

7

11 2 x 8-ports KVM switch

13* 2 or 4 PDU(s) with AC power cable

18 KVM extender (local)

* Redundant servers are connected to 2 PDUs and have 4 DPS units.

Figure 7.

NovaScale 5325 Partitioned Servers components - example

8 U x

4

1 U x

2

1 U

1-10 User's Guide

I/O Cabinet

10 PAP unit with CD-ROM writer, FDD and 2 disks

13 2 PDU(s) with AC power cable

14 2 FC disks

18 KVM extender (remote)

Figure 8.

NovaScale 5325 Partitioned Servers components - example

1 U

3x2 U

1 U

Introducing the Server 1-11

Server Components

Note:

Server components and configuration may differ according to the version chosen.

The server includes the following components:

CSS module, on page 1-13

Integrated console, on page 1-15

Integrated Platform Administration Processor (PAP) unit, on page 1-14

Keyboard / Video / Mouse (KVM) switch, on page 1-16

Fibre Channel (FC) disks, on page 1-17

Ethernet hub, on page 1-19

USB modem, on page 1-19

NPort server, on page 1-19

1-12 User's Guide

Central Subsystem (CSS) Module

The CSS module houses main hardware components:

Front Rear

Front 1 or 2 QBB (Quad Brick Board) subset(s):

Each QBB subset houses:

• 1 mother board

• 2 memory boards

• 1 to 4 processors

• 16 DIMMs

1 or 2 Internal Peripheral Drawer(s):

Each drawer houses:

• 2 internal SCSI RAID system disks

1 DVD-ROM driv e

• 1 USB port

Chaine d DIBs:

Two Internal Peripheral Drawers can be inter-connected to house:

• 4 SCSI RAID disks, 1 DVD-ROM drive, 1 USB port

Rear 1 or 2 IO Box(es) (Input / Output Board Compact):

Each IO Box can house:

1 HPB (PCI Hot Plug Board)

6 hot-plug 133 MHz PCI-X and PCI Xpress slots (2 long, 4 short)

1 IOL (Input / Output board Legacy):

- 2 A-type USB ports

- 1 RJ45 10/100/1000 Mbps Ethernet port

- 2 DB9-M RS232 serial ports

- 1 HD15-F VGA port

1 PMB (Platform Management Board):

This active board links the server to the Platform Administration Processor (PAP) Unit

(via an Ethernet link).

Core 1 Core unit

This set of 5 active boards is used to interconnect the QBBs, IOCs, DIBs and the

PMB.

Figure 9.

CSS module features (full CSS module example)

Introducing the Server 1-13

Integrated Platform Administration Processor (PAP) Unit

Warning:

The PAP unit has been specially configured for Bull NovaScale Server administration and maintenance. NEVER use the PAP unit for other purposes and NEVER change PAP unit configuration unless instructed to do so by an authorized Customer Service Engineer.

The PAP unit is linked to the server via the Platform Management Board (PMB). It hosts

Platform Administration Software (PAM). According to version, the PAP unit is located in the center of a high cabinet or at the top of a low cabinet.

PAP Unit 1U

• 1 P4C / 3 GHz PC

- 1 GB RAM

- 2 x 80 GB SATA disks (RAID1)

- 1 CD/DVD-ROM drive

- 1 1 FDD

- 2 serial ports

- 1 parallel port

- 3 PCI slots

- 2 Gigabit Ethernet ports (1 free)

- 3 USB 2.0 ports (1 front + 2 rear)

- 1 SVGA video port

- 2 PS/2 ports

• Microsoft Windows operating system

• Internet Explorer software

• PAM software

• 1 power cable

Figure 10. PAP unit

1-14 User's Guide

Integrated Console

According to version, the console is located in the center of a high cabinet or at the top of a low cabinet.

The inegrated console contains the keyboard, monitor and touch pad used for local access to the server and to the Platform Administration Processor (PAP) Unit.

or

• 1 monitor

• 1 QWERTY keyboard and touch pad

• 1 power cable

Figure 11. Integrated console features

Introducing the Server 1-15

Keyboard / Video / Mouse (KVM) Switch

The KVM Switch allows the use of the integrated console for the local server and the local

Platform Administration and Maintenance console.

8-Port KVM Switch

Or

Or

• 8 ports

• 1 power cable

Figure 12. 8-port KVM switch features

16-Port KVM Switch

KVM Extender

• 16 ports

• 1 power cable

Figure 13. 16-port KVM switch features

Figure 14. KVM extender (local & remote) 300m maxi.

1-16 User's Guide

FDA 1x00 FC Disk Rack

Optionally, the FDA 1x00 FC Disk Rack is delivered with pre-installed system disks (two

RAID#1 and one spare disk per domain). Empty slots can be used for data disks. According to version, the Disk Rack is located in the main or I/O cabinet.

• 15 slots

• 2 FC RAID controller cards, 1 FC port per controller

• 3 disks per domain (2 RAID#1 + 1 spare)

• 2 power cables (redundant power supply)

Figure 15. FDA 1x00 FC disk rack features

FDA 2x00 FC Disk Rack

Optionally, the FDA 2x00 FC Disk Rack is delivered with pre-installed system disks (two

RAID#1 and one spare disk per domain). Empty slots can be used for data disks. According to version, the Disk Rack is located in the main or I/O cabinet.

• 1 controller unit & 1 disk unit

• 15 slots

• 2 FC RAID controller cards, 2 FC ports per controller

• 3 disks per domain (2 RAID#1 + 1 spare)

• 2 power cables (redundant power supply)

Figure 16. FDA 2x00 FC disk rack features

Introducing the Server 1-17

FDA 1x00 FC Extension Disk Rack

The FDA 1x00 FC Extension Disk Rack offers15 empty slots for data disks. According to version, the Disk Rack is located in the main or I/O cabinet.

• 15 slots

• 2 power cables (redundant power supply)

Figure 17. FDA 1x00 FC extension disk rack features

1-18 User's Guide

Ethernet Hub

The optional Maintenance LAN Ethernet Hub is used to connect PMB, PAP Unit and external

FDA FC Disk Rack Ethernet ports.

Ethernet Hub

-

-

-

8 ports

1 power cable

1 power bar

Figure 18. Ethernet hub features

USB Modem

The optional USB modem is used to transmit Autocalls to the Remote Maintenance Center, if your maintenance contract includes the Autocall feature.

USB Modem

-

1 USB cable

1 RJ11 cable

Figure 19. USB modem features

NPort Server

The Nport Server is used connect the administration port of the SR-0812 SCSI RAID disk rack to the PAP Unit.

NPort Server

-

2 DB9 to Jack cable

1 RJ45 - RJ45 Ethernet cable

Figure 20. NPort Server features

Introducing the Server 1-19

Accessing Server Components

During normal operation, cabinet components can be accessed from the front. Customer

Service Engineers may also remove the rear and side covers for certain maintenance operations.

Important:

Optimum cooling and airflow is ensured when the cabinet door is closed.

Opening the Front Door

Tools Required:

• Cabinet key

Figure 21. Opening the front door

1. Unlock the front door with the key.

2. Pull out the locking mechanism and turn to open.

3. Open the door as required.

Closing the Front Door

1. Close the door.

2. Turn the locking mechanism to close and push back into place.

3. Lock the front door with the key.

1-20 User's Guide

Opening / Closing the Integrated Console

The server is equipped with an integrated console for local administration and maintenance operations.

Figure 22. Integrated console example

To open the integrated console:

1. Slide the console forward until it clicks into place.

2. Use the front bar to lift the screen panel into position.

To close the integrated console:

1. Press the 2 buttons marked PUSH on either side of the keyboard panel to release the console.

2. Lower the front bar to close the screen panel.

3. Slide the console back into the cabinet.

Introducing the Server 1-21

Bull NovaScale Server Resources

Note:

According to server configuration and version, certain features and functions described in this guide may not be accessible. Please contact your Bull Sales Representative for sales information.

System Resource and Documentation CD-Roms

The Bull NovaScale Server System Resource and Documentation CD-Roms contain all the firmware and documentation referred to in this guide.

PAM Software Package

The Bull NovaScale Server is equipped with an integrated Platform Administration and

Maintenance software package, otherwise known as the PAM software package.

One part of PAM software is an embedded application (MAESTRO) running on the Platform

Management Board(s) (PMB) and the other is an external application (PAM Kernel / Web

User Interface) running on the Platform Administration Processor (PAP) unit under Microsoft

Windows.

CSS Module

Access to

Hardware Elements

PMB

(MAESTRO)

Internal Ethernet Link

PAP Unit

(PAM Kernel / Web User Interface)

Figure 23. PAM software deployment

The PAM Web-based administration and maintenance tools give you immediate insight into system status and configuration. You will use PAM software to operate, monitor, and configure your Bull NovaScale Server.

As soon as your system is connected to the power supply, the PAP unit running Microsoft

Windows and PAM software also powers up. For further information about connecting to

PAM, see Connecting to the PAM Web Site, on page 2-2.

PAP Unit Mirroring and Failover Policy

Most configuration, administration, and maintenance activities are carried out from the PAP unit. To ensure a high level of data integrity and availability, the PAP unit is equipped with two extractable mirrored disks. Mirroring writes and updates data across both disks, creating a single logical volume with completely redundant information on each disk. If one disk fails, it can be replaced without losing data.

Note:

For enhanced data integrity and availability, the PAP unit can be equipped with a third disk.

Contact your Customer Representative for details.

1-22 User's Guide

EFI Utilities

The Bull NovaScale Server EFI utilities provide a complete set of configuration, operation, and maintenance tools:

• EFI driver,

• EFI Shell,

• EFI system utility,

• EFI system diagnostic,

• Operating System loader.

For further details, see Chapter 5. Tips and Features for Administrators.

Introducing the Server 1-23

1-24 User's Guide

Chapter 2. Getting Started

This chapter explains how to connect to and start server domains. It includes the following topics:

Connecting to the PAM Web Site, on page 2-2

PAM User Interface, on page 2-5

Setting up Users, on page 2-8

Toggling the Local / Integrated Console Display, on page 2-9

Powering Up / Down the NovaScale 5xx5 SMP Server Domain, on page 2-10

Powering Up / Down NovaScale 5xx5 Partitioned Servers Domains, on page 2-12

Preparing Server Domains for Remote Access via the Enterprise LAN, on page 2-16

Preparing Server Domains for Remote Access via the Web, on page 2-18

Connecting to a Server Domain via the Enterprise LAN, on page 2-19

Connecting to a Server Domain via the Web, on page 2-20

Installing Applications, on page 2-21

Note:

Customer Administrators and Customer Operators are respectively advised to consult the

Administrator's Memorandum, on page xxv or the Operator's Memorandum, on page xxvii

for a detailed summary of the everyday tasks they will perform.

Getting Started 2-1

Connecting to the PAM Web Site

The server is equipped with an integrated Platform Administration and Maintenance software package, otherwise known as PAM software. One part of PAM software is an embedded application (MAESTRO) running on the Platform Management Board (PMB) and the other is an external application running on the Platform Administration Processor (PAP) unit under

Microsoft Windows.

The PAM Web-based administration and maintenance tools give you immediate insight into system status and configuration. You will use PAM software to operate, monitor, and configure your server.

Note:

Local and remote access rights to the PAP unit and to the PAM Web site must be configured by the Customer Administrator. For further details, refer to the Microsoft Windows

documentation and to Setting up PAP Unit Users, on page 5-17.

Customer Administrator rights are required for all PAM configuration tasks.

Connecting to the PAM Web Site from the Local / Integrated Console

CAUTION:

Access to the local / integrated console should be restricted to Customer / Support

Administrators and Operators ONLY to avoid inadvertent damage to software and/or hardware components.

1. Check that the KVM switch is set to the PAP Unit port. See Toggling the Local / Integrated

Console Display, on page 2-9.

2. From the PAP unit Microsoft Windows desktop, double-click the PAM icon

(http://localhost/PAM).

3. When prompted, enter the appropriate Administrator or Operator User Name and

Password. The PAM home page appears.

2-2 User's Guide

Connecting to the PAM Web Site from a Remote Computer

The PAM Software utility can be accessed from any PC running Microsoft Windows with the

Internet Explorer (6 or later) browser installed and/or from any workstation running Linux with the Mozilla (1.7 or later) or Firefox (1.0) browsers installed.

Important:

Before connecting to PAM from a remote computer, you are advised to disconnect from your local Windows session on the PAP unit by clicking Start → Log Off.

If Pop-up Blocker is turned on in your Web Browser, you MUST add the PAM Web site to the list of allowed sites.

Do NOT use the Mozilla or Firefox browsers on the PAP unit.

Enabling Remote Access to the PAM Web Site with Internet Explorer, Mozilla, or Firefox

1. From the remote computer, configure the browser to connect directly to the PAM Web site by entering the PAM Web site URL defined during the PAP installation procedure in the

Home Page Address field: http://<PAPname>/pam

(where <PAPname> is the name allocated to the PAP unit during setup).

2. Launch the browser to connect directly to the PAM web site.

3. When prompted, enter the appropriate Administrator or Operator User Name and

Password. The PAM home page appears.

Getting Started 2-3

Simultaneous Connection to the PAM Web Site

Several users can access the PAM Web site simultaneously.

Important:

If configuration changes are made, they may not be visible to other users unless they refresh the PAM Tree.

As Customer Administrator, you can view the list of PAM users currently logged onto the PAM

Web site by clicking Hardware Monitor -> PAM Web Site.

The Web site version and a list of connected users and session details are displayed in the

Control pane.

The icon indicates the current session.

Figure 24. PAM Web site session details

You can also open several browser sessions from the same computer to obtain different views of system operation. For example, as Customer Administrator, you may want to open a first session for permanent and easy access to powering on/off functions, a second session for access to system histories and archives, and a third session for access to configuration menus, as shown in the following figure.

Figure 25. Multiple session example

2-4 User's Guide

PAM User Interface

The PAM user interface is divided into three areas in the browser window: a Status pane, a

PAM Tree pane, and a Control pane.

A

B

C

Status pane, on page 2-6

PAM Tree pane, on page 2-7

Control pane, on page 2-6

Figure 26. PAM user interface

Getting Started 2-5

Checking Server Status via PAM

The PAM user interface allows you to check system status at a glance. If the Functional Status icon in the Status pane and the CSS Availability Status bar are green, the server is ready to be powered up.

PAM Status Pane

The Status pane, which is automatically refreshed every few seconds, provides quick access to the following synthetic information:

• Functional Status: if the system is operating correctly, the status icon is green,

• Event Messages: shows the number and maximum severity of pending event messages,

• CSS Availability Status: if the CSS Module PMB is detected as present, is configured correctly, and is ready to operate, the status bar is green.

A

B

C

System Functional Status icon

E

CSS Availability Status icon

Presence/Functional Status toggle button

F

Event Message Severity icon

Event Message Viewer

G

New Event Message icon

D

Pending Event Message icon

Figure 27. Status pane

PAM Control Pane

When an item is selected in the PAM Tree pane, details and related commands are displayed in the Control pane, which is automatically refreshed at one minute intervals.

2-6 User's Guide

CSS Availability Status Bar

The CSS availability status bar reflects the operational status of the data link(s) between the

Platform Management Board (PMB) embedded in each CSS Module and the PAP Unit. Each

CSS module is represented by a zone in the status bar.

• When a CSS Module PMB is detected as PRESENT, the corresponding zone in the status bar is GREEN.

• When a CSS Module PMB is detected as ABSENT, the corresponding zone in the status bar is RED.

• When you hover the mouse over the status bar, an Infotip displays the presence status of

CSS Module PMB - PAP Unit data links.

The following figure represents the status bar for a bi-module server. One CSS Module PMB is detected as PRESENT and the other is detected as ABSENT.

A: Bar red (CSS Module_0 not available)

Figure 28. CSS Module availability status bar (bi-module server)

PAM Tree Pane

Note:

The PAM tree builiding process may take one to two minutes. The PAM tree pane is refreshed on request.

The PAM Tree pane provides access to server administration and maintenance features:

Tree Nodes

Domain Manager

Hardware Monitor

History Manager

Configuration Tasks

Table 3.

PAM Tree nodes

Function

to power on / off and manage domains. See Chapter 3.

Managing Domains.

to display the status of hardware components and assemblies. See Chapter 4. Monitoring the Server.

to view logs and manage archives.See Chapter 4. Monitoring the Server.

to customize server features.See Chapter 5. Tips and Features for Administrators.

Getting Started 2-7

PAM Tree Toolbar

The PAM Tree toolbar, located at the top of the PAM Tree, is used to refresh, expand, or collapse the tree display.

Toolbar Buttons

Figure 29. PAM Tree toolbar

Explanation

Refresh /rebuild the PAM Tree to view changes.

Expand the complete tree.

Collapse the complete tree.

Expand selected node.

Collapse selected node.

View the related

Help

topic.

Setting up Users

As Customer Administrator, you must set up user accounts and passwords to control access to

the PAP unit. See Setting up PAP Unit Users, on page 5-17.

2-8 User's Guide

Toggling the Local / Integrated Console Display

During the powering up / down sequences, you will be requested to toggle the local / integrated console from the PAP unit display to the server domain display, or vice versa, as explained below.

CAUTION:

Access to the local / integrated console should be restricted to Customer / Support

Administrators and Operators ONLY to avoid inadvertent damage to software and/or hardware components.

The KVM Switch allows the integrated console to be used as the local server domain and local PAP unit console. KVM ports are configured as shown in Table 4.

NovaScale 5xx5 SMP Server

8-port KVM Switch

Port 1

Port 2

Console Display

PAP Unit

Server Domain

Domain

N/A

N/A

NovaScale 5xx5 Partitioned Server

16-port KVM Switch

Port 1

Port 2

Port 3

Port 4

Port 5

Port 6

Port 7

Port 8

Port 9

Console Display

PAP Unit

CSS0-Mod0-IO0

CSS0-Mod0-IO1

CSS0-Mod1-IO0

CSS0-Mod1-IO1

CSS0-Mod2-IO0

CSS0-Mod2-IO1

CSS0-Mod3-IO0

CSS0-Mod1-IO1

Domain

N/A

MyOperations-xx-1

MyOperations-xx-2

MyOperations-xx-3

MyOperations-xx-4

MyOperations-xx-5

MyOperations-xx-6

MyOperations-xx-7

MyOperations-xx-8

Table 4.

KVM port configuration

You can easily toggle from the server domain display to the PAP unit display, or vice versa:

1. To display the KVM Switch Command Menu from the keyboard a. If you have a KVM switch "Avocent SwitchView 1000" installed, press the "Scroll

Lock" key twice then the Space key.

b. If you have another KVM switch installed, press the Control key twice.

2. Select the required port with the ↑↓ keys and press Enter.

3. The selected display appears on the Console monitor.

Getting Started 2-9

Powering Up / Down Server Domains

To power up / down the server, see:

Powering Up / Down the NovaScale 5xx5 Partitioned Server Domains, on page 2-12

Powering Up the NovaScale 5xx5 SMP Server Domain

NovaScale 5xx5 SMP Servers are designed to operate as single SMP systems and are delivered with one pre-configured domain.

When server status has been checked - functional status icon and CSS availability status bar green in the Status pane - the server domain can be powered up.

Note:

If an error dialog box appears during this sequence, see Chapter 3. Managing Domains.

To power up server domains:

4. From the PAM Tree, click Domain Manager to open the Control pane. A dialog box invites you to load the server domain.

5. Click OK to confirm. The domain appears in the Control pane. If the domain is ready to be powered up, INACTIVE is displayed in the Domain State box and the Power On button is accessible.

6. Select the domain and click Power On to power up the server domain and associated hardware components.

1

2

3

Functional status icon

CSS availability status indicator (GREEN)

Operating system type

Figure 30. Domain Manager Control pane

2-10 User's Guide

7. Follow the power-on steps displayed in the Domain State box, until RUNNING is displayed.

Figure 31. Domain state

8. Toggle the local / integrated console from the PAP unit display to the server display. See

Toggling the Local / Integrated Console Display, on page 2-9.

9. Wait for the Operating System to load completely. The domain is now fully functional.

10.Check the Operating System environment pre-installed on the domain.

11.As Customer Administrator, you can now prepare each domain for remote access via the

Enterprise LAN and/or via the Web. See Preparing Server Domains for Remote Access

via the Enterprise LAN, on page 2-16 and Preparing Server Domains for Remote Access

via the Web, on page 2-18.

Powering Down the NovaScale 5xx5 SMP Server Domain

Note:

If an error dialog box appears during this sequence, see Chapter 3. Managing Domains.

1. Shut down the Operating System to power down the domain to the stand-by mode.

2. Toggle the local / integrated console to the PAP unit display. INACTIVE is displayed in the

Domain State box and the Power ON button is accessible.

Note:

For further details about the Power ON / OFF sequences, see Powering ON a Domain, on

page 3-14 and Powering OFF a Domain, on page 3-18.

• If the same PAP unit administers more than one server, all servers can be powered on simultaneously as follows: a. Click Multiple Power. The Multiple Power Domains On/Off dialog opens.

b. Click Power On All → Execute to power on the servers and associated hardware components.

• For further details about the Power ON / OFF sequences, see Powering ON a Domain and

Powering OFF a Domain in the User's Guide.

Getting Started 2-11

Powering Up NovaScale 5xx5 Partitioned Server Domains

According to version, NovaScale 5xx5 Partitioned Servers are designed to operate as up to eight hardware-independent SMP systems, or domains.

For easy configuration and optimum use of the physical and logical resources required for simultaneous operation, domains are defined by the Customer Administrator via the PAM

Domain Scheme wizard. For further details about domain configuration, see Configuring

Domains, on page 5-28.

The server is delivered with a default scheme, or configuration file, called

MyOperationsScheme-xx, containing up to eight domains:

• MyOperations-xx-1

• MyOperations-xx-2

• MyOperations-xx-3

• MyOperations-xx-4

• MyOperations-xx-5

• MyOperations-xx6

• MyOperations-xx7

• MyOperations-xx-8

This default scheme allows you to simultaneously boot all domains.

According to your requirements, identical or different Operating System instances may be pre-installed on each domain boot disk (EFI LUN).

Notes:

• xx in the default scheme and domain names represents the Central Subsystem HW identifier (from 00 to 15). For further details, refer to

For further details, refer to PMB Leds and Code Wheels, on page 4-50.

• Operating System type is indicated by the Microsoft Windows or Linux logo in the

Domain Identities box.

• If an error dialog box appears during these sequences, see Chapter 3. Managing

Domains.

• A Scheme comprising 4 domains is used to illustrate the following example.

2-12 User's Guide

To power up server domains:

3. From the PAM Tree, click Domain Manager to open the Control pane. You are invited to load a domain configuration scheme.

4. Click Schemes. The Schemes List dialog opens displaying the pre-configured scheme.

5. Select MyOperationsScheme and click Apply.

Figure 32. Domain schemes list dialog

6. When requested, click Yes to confirm. The default domains are loaded in the Control pane.

If the domains are ready to be powered up, INACTIVE is displayed in the Domain State boxes and the Power On button is accessible for each domain.

1

2

3

Functional status icon

CSS availability status indicator (GREEN)

Operating system type

Figure 33. Domain Manager Control pane - example with 4 domains

7. Click Multiple Power. The Multiple Power Domains On/Off dialog opens.

Getting Started 2-13

8. Click Power On All → Execute to simultaneously power on the domains and associated hardware components.

Figure 34. Multiple power dialog - example with 4 domains

Note:

Domains can also be powered on sequentially from the Control pane:

• Select a domain in the Control pane and click Power On to power up the domain and associated hardware components. Repeat this step for each domain in the Control pane.

9. Follow the power-on steps displayed in the Domain State boxes, until RUNNING is displayed in all Domain State boxes.

Figure 35. Domain state - example with 4 domains

10.Toggle the local / integrated console from the PAP unit display to the first domain display.

See Toggling the Local / Integrated Console Display, on page 2-9.

11.Wait for the Operating System to load completely. The domain is now fully functional.

12.Toggle the local / integrated console from this domain display to the next domain display.

13.Wait for the Operating System to load completely. The domain is now fully functional.

14.Repeat Steps 12 and 13 for each domain.

15.Check the Operating System environment pre-installed on each domain.

2-14 User's Guide

16.As Customer Administrator, you can now prepare each domain for remote access via the

Enterprise LAN and/or via the Web. See Preparing Server Domains for Remote Access

via the Enterprise LAN, on page 2-16 and Preparing Server Domains for Remote Access

via the Web, on page 2-18.

Powering Down NovaScale 5xx5 Partitioned Server Domains

1. Shut down each Operating System to power down the corresponding domain to the stand-by mode.

2. Toggle the local / integrated console to the PAP unit display. INACTIVE is displayed in the

Domain State boxes and the Power ON button is accessible for each domain.

Note:

For further details about the Power ON / OFF sequences, see Powering ON a Domain, on

page 3-14 and Powering OFF a Domain, on page 3-18.

Getting Started 2-15

Preparing Server Domains for Remote Access via the Enterprise LAN

CAUTION:

Access to the local / integrated console should be restricted to Customer / Support

Administrators and Operators ONLY to avoid inadvertent damage to software and/or hardware components.

Note:

Required networking data is indicated in the Read Me First document delivered with the server and is also recorded under the corresponding PAM Domain Identity.

Customer Administrator rights are required for all PAM configuration tasks.

Microsoft Windows Domain

1. Toggle the integrated console to the corresponding Windows domain port. See Toggling

the Local / Integrated Console Display, on page 2-9.

2. From the Windows desktop, right click My Computer and select Properties → Remote.

3. Check the Allow remote connection box.

4. Share the <system root>\system32\clients\tsclient directory via the Explorer.

5. Toggle the integrated console to the PAP unit port.

6. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Identities to open the Identities page.

7. Select the corresponding Windows domain from the list and click Edit to open the Edit an

Identity dialog.

8. Check that the Network Name, IP Address, and URL fields are completed. If not, complete these fields with the networking data entered during the Windows setup completion procedure and click OK.

Linux Redhat Domain

1. Toggle the integrated console to the corresponding Linux domain port. See Toggling the

Local / Integrated Console Display, on page 2-9.

2. From the Linux desktop, enable remote connection via telnet, rlogin, ftp, ...:

3. From the PAP unit Internet Explorer or Mozilla browser, enter the Webmin URL: http://<networkname>:10000, where <networkname> is the network name given to the server domain during the Linux setup completion procedure.

The Login to Webmin dialog box opens.

4. Click the Networking icon. The Networking main page opens.

5. Click Extended Internet Services to display the list of available services.

6. From the service list, check that Yes is displayed in the status column. If No is displayed in the status column, proceed as follows to enable the service: a. Select the required service from the list.

b. Complete the fields accordingly.

c. Click Yes after Service enabled?

d. Click Save.

7. Repeat step 3 for each required service.

8. Click Apply changes to apply all changes.

2-16 User's Guide

9. Click Return to index.

10.Click Log Out to exit Webmin.

11.Toggle the integrated console to the PAP unit port.

12.From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Identities to open the Identities page.

13.Select the corresponding Linux domain from the list and click Edit to open the Edit an

Identity dialog.

14.Check that the Network Name, IP Address, and URL fields are completed. If not, complete these fields with the networking data entered during the Linux setup completion procedure and click OK.

Linux SuSE Domain

1. Toggle the integrated console to the corresponding Linux domain port. See Toggling the

Local / Integrated Console Display, on page 2-9.

2. From the Linux desktop, enable remote connection via telnet, rlogin, ftp, ...:

3. Launch the yast2 command to open the Yast Control Center screen.

4. Click the Network/Basic icon in the left pane.

5. Click Start/stop services (inetd).

6. From the Network Services page, select On with customer configuration and click Next to open the Enable/disable network services page.

7. From the service list, check that Active is displayed in the status column. Proceed as follows to enable the service: a. Select the required service from the list.

b. Click Activate.

8. Repeat step 5 for each required service.

9. Click Finish to apply all changes.

10.Click Close to exit yast2.

11.Toggle the integrated console to the PAP unit port.

12.From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Identities to open the Identities page.

13.Select the corresponding Windows domain from the list and click Edit to open the Edit an

Identity dialog.

14.Check that the Network Name, IP Address, and URL fields are completed. If not, complete these fields with the networking data entered during the Linux setup completion procedure and click OK.

Getting Started 2-17

Preparing Server Domains for Remote Access via the Web

CAUTION:

Remote access via the Web is a potential security hazard. Customers are strongly advised to protect their systems with up-to-date protection devices such as virus-prevention programs and firewalls, and to maintain a detailed record of authorized users.

Microsoft Windows Domain

1. Toggle the integrated console to the corresponding Windows domain port. See Toggling

the Local / Integrated Console Display, on page 2-9.

2. Left click Start → Control Panel → Add or Remove Programs.

3. Select Add / Remove Windows Components.

4. Click Web Application Services → Details → Internet Information Services → Details →

World Wide Web Services → Details → Remote Desktop Web Connection. Validate where required by clicking OK or Next.

5. Insert the the Microsoft Windows CD-ROM in the CD-ROM / DVD drive.

6. The Microsoft Windows setup wizard is launched automatically and guides you through the setup completion procedure.

7. Toggle the integrated console to the PAP unit port.

8. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Identities to open the Identities page.

9. Select the corresponding Windows domain from the list and click Edit to open the Edit an

Identity dialog.

10.Check that the Network Name, IP Address, and URL fields are completed. If not, complete these fields with the networking data entered during the Windows setup completion procedure and click OK.

Linux Domain

Virtual Network Computing (VNC) remote control software allows users to interact with the server from a remote computer via Internet.

The server domain is ready for remote connection.

1. Toggle the integrated console to the PAP unit port.

2. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Identities to open the Identities page.

3. Select the corresponding Linux domain from the list and click Edit to open the Edit an

Identity dialog.

4. Check that the Network Name, IP Address, and URL fields are completed. If not, complete these fields with the networking data entered during the Linux setup completion procedure and click OK.

2-18 User's Guide

Connecting to a Server Domain via the Enterprise LAN

Microsoft Windows Domain

1. Check that Client for Microsoft Networks is installed on the remote computer and that the remote computer is connected to the same LAN as the server domain.

2. Check that Client for Remote Desktop is installed on the remote computer. If the Remote

Desktop Connection menu does not exist: a. Click Start → Run.

b. Type \\<networkname>\tsclient\win32\setup.exe in the box, where <networkname> is the network name given to the server domain during the Windows setup completion procedure.

3. Connect to the server domain by running: a. Microsoft Windows XP (and later):

All Programs → Accessories → Communication → Remote Desktop Connection.

b. All other versions of Microsoft Windows:

Programs → Remote Desktop Connection → OK.

4. Type Administrator (default administrator user name) in the User name field.

5. Type the administrator password defined during the Windows setup completion procedure in the Password field.

6. The remote computer connects to the server domain.

Linux Domain

1. Enter the following command: ssh <networkname> -l user_name, where <networkname> is the network name given to the server domain during the Linux setup completion procedure.

2. The remote computer connects to the server domain.

Getting Started 2-19

Connecting to the Server via the Web

Microsoft Windows Domain

1. Check that Internet Explorer (6 or later) and Terminal Server Client are installed on the remote computer.

2. Launch the Internet Explorer or Netscape browser and connect to the server desktop, url: http://<networkname>/tsweb/, where <networkname> is the network name given to the server domain during the Windows setup completion procedure. See the Read Me First document delivered with the server.

Linux Domain

Virtual Network Computing (VNC) remote control software allows users to interact with the server from a remote computer via Internet.

1. Check that VNC Server is installed.

2. Execute the vncpasswd command to initialize the password.

3. Execute the vncserver command to start the process.

4. Record the <networkname> display number for the remote computer, where

<networkname> is the network name given to the server domain during the Linux setup completion procedure.

2-20 User's Guide

Installing Applications

Important:

Reserved for partitioned servers and extended systems. Please contact your Bull Sales

Representative for sales information.

When you install an application protected by a system serial number, you are requested to supply this serial number.

For optimum flexibility, PAM software allows you to replace the physical serial number by a logical licensing number so that you can run the application on any physical partition and, in the case of extended systems, on any of the Central Subsystems within the extended configuration.

For details on how to define and manage the logical licensing number, please refer to

Creating, Editing, Copying, Deleting a Domain Identity, on page 5-50.

Getting Started 2-21

2-22 User's Guide

Chapter 3. Managing Domains

This chapter explains how, as Customer Administrator and/or Customer Operator, you can manage server domains. It includes the following topics:

Introducing PAM Domain Management Tools, on page 3-2

Managing Domain Configuration Schemes, on page 3-5

Synchronizing NovaScale 5xx5 SMP Server Domains, on page 3-6

Powering On a Domain, on page 3-14

Powering Off a Domain, on page 3-18

Forcing a Domain Power Off, on page 3-21

Performing a Domain Memory Dump, on page 3-24

Manually Resetting a Domain, on page 3-25

Deleting a Domain, on page 3-26

Viewing the Domain Fault List, on page 3-28

Viewing Domain Functional Status, on page 3-29

Viewing Domain Power Logs, on page 3-31

Viewing Domain Powering Sequences, on page 3-32

Viewing Domain BIOS Info, on page 3-33

Viewing Domain Request Logs, on page 3-34

Viewing Domain Configuration, Resources and Status, on page 3-35

What to Do if an Incident Occurs, on page 3-42

Note:

Customer Administrators and Customer Operators are respectively advised to consult the

Administrator's Memorandum, on page xxv or the Operator's Memorandum, on page xxvii

for a detailed summary of the everyday tasks they will perform.

For further information about user accounts and passwords, see Setting up PAP Unit Users,

on page 5-17.

Managing Domains 3-1

Introducing PAM Domain Management Tools

Important:

Certain domain configuration and management tools are reserved for use with partitioned servers and extended systems. Please contact your Bull Sales Representative for sales information.

A Bull NovaScale Server domain englobes all the hardware and software resources managed by an Operating System instance.

NovaScale 5xx5 SMP Servers are designed to operate as single SMP systems and are delivered with one pre-configured domain.

NovaScale 5xx5 Partitioned Servers are designed to operate as one, two, three or four hardware-independent SMP systems or domains, each running an Operating System instance and a specific set of applications.

The PAM Domain Manager is at the heart of server operation and the Control pane is frequently used during operation. The Domain Manager Control pane gives access to all domain commands and domain details.

What You Can Do

Via the Domain Manager Control pane, you can:

• Manage domain configuration schemes

• Power on a domain

• Power off a domain

• Perform a domain reset

• Perform a domain force power off

• Request a domain memory dump

• View functional status

• View power logs

• View powering sequences

• View BIOS info

• View request logs

• View domain configuration, resources and status

Note:

Access to certain hardware resources, such as system disks can be limited by using the

Exclusion / Inclusion function. See Limiting Access to Hardware Resources, on page 5-66

and Excluding / Including Hardware Elements, on page 4-23. This function must be used

with care.

3-2 User's Guide

From the PAM Tree, click Domain Manager to open the Control pane.

Multiple Power

Powering View

Expand All

Schemes

Save Snapshot

Domain Identities

Domain State

Functional Status

Toolbar (1)

Allows you to simultaneously power on /off several domains. See

Powering ON a Domain, on page 3-14 and Powering OFF a

Domain, on page 3-18.

Dynamically displays domain power sequences and gives access

to Power Logs, see details on page 3-31 and BIOS Info, see de-

tails on page 3-33.

Expands the list of domains included in the current domain configuration.

Loads a selected scheme and displays Scheme Properties, see

details on page 3-8.

Saves current domain configuration as a new scheme for future

use, see details on page 3-11.

Status Panel (2)

The names given to clearly identify domains, see details on page

5-28.

Power sequence state. See Powering ON a Domain, on page

3-14 and Powering OFF a Domain, on page 3-18.

Status of the last action performed on a domain. See Viewing

Domain Functional Status, on page 3-29.

Managing Domains 3-3

Command Bar (3)

Powers on the selected domain, see details on page 3-14.

Power On

Power Off

Powers off the selected domain, see details on page 3-18.

Reset

Resets the selected domain, see details on page 3-25.

Force Power Off

Power Logs

Request Logs

Fault List

Forcibly powers off the selected domain, see details on page

3-21.

Displays power sequence logs, see details on page 3-31.

Displays Power On, Power Off, and Reset requests and request-

ors, see details on page 3-34.

Gives access to the domain fault list, see details on page 3-28.

Performs a domain memory dump, see details on page 3-24.

Dump

View

Delete

Opens the View Domain dialog, which displays domain configuration data and gives access to Domain Resources, see details on

page 3-35 and BIOS Info, see details on page 3-33.

Removes the selected domain from the current domain configura-

tion, see details on page 3-26.

Table 5.

PAM Domain Manager tools

3-4 User's Guide

Managing Domain Configuration Schemes

Important:

Reserved for partitioned servers and extended systems.

Certain features described below are only available if you are connected to a Storage Area

Network (SAN).

Please contact your Bull Sales Representative for sales information.

What You Can Do

Via the Schemes tool in the Domain Manager Control pane toolbar, you can:

• View a domain configuration scheme

• Load a domain configuration scheme

• Add domains to the current domain configuration

• Replace the current domain configuration

• Save the current domain configuration snapshot

A Domain Configuration Scheme is the template or configuration file used to define and manage a set of domains that can be active simultaneously. For easy configuration and optimum use of the physical and logical resources required for simultaneous operation, domains are defined via the PAM Domain Configuration Scheme wizard.

Note:

Server components and configuration may differ according to site requirements.

NovaScale 5xx5 SMP Server

NovaScale 5xx5 SMP Servers are designed to operate as single SMP systems and are delivered with one pre-configured domain.

NovaScale 5085 Partitioned Server

The NovaScale 5085 Partitioned Server is designed to operate as one or two hardware-independent domains. The server is delivered with a pre-configured domain configuration scheme called MyOperationsScheme containing two domains, MyOperations-1 and MyOperations-2, allowing you to manage and administer all server resources.

NovaScale 5165 Partitioned Server

The NovaScale 5165 Partitioned Server is designed to operate as one, two, three or four hardware-independent domains. The server is delivered with a pre-configured domain configuration scheme called MyOperationsScheme containing four domains,

MyOperations-1, MyOperations-2, MyOperations-3 and MyOperations-4, allowing you to manage and administer all server resources.

NovaScale 5245 Partitioned Server

The NovaScale 5245 Partitioned Server is designed to operate as from one to six hardware-independent domains. The server is delivered with a pre-configured domain configuration scheme called MyOperationsScheme containing six domains, MyOperations-1,

MyOperations-2, MyOperations-3, MyOperations-4, MyOperations-5 and MyOperations-6, allowing you to manage and administer all server resources.

Managing Domains 3-5

NovaScale 5325 Partitioned Server

The NovaScale 5325 Partitioned Server is designed to operate as from one to heigh hardware-independent domains. The server is delivered with a pre-configured domain configuration scheme called MyOperationsScheme containing four domains,

MyOperations-1, MyOperations-2, MyOperations-3, MyOperations-4, MyOperations-5

MyOperations-6, MyOperations-7 and MyOperations-8, allowing you to manage and administer all server resources.

Note:

As Customer Administrator, you may configure other schemes for domain management. For

further details about domain configuration options, see Configuring Domains, on page 5-28.

To power on server domains, you must first load the required Domain Configuration Scheme from the Domain Manager Control pane. Once the domain configuration scheme has been loaded, domains can be powered up simultaneously or sequentially.

Synchronizing NovaScale 5xx5 SMP Server Domains

The Synchronize Domains command is used to load the NovaScale 5xx5 SMP Server domain. Each NovaScale 5xx5 SMP Server is delivered with one pre-configured domain.

To load the server domain:

Click Synchronize Domains in the toolbar. The server domain(s) appear(s) in the Control pane for management.

The other Schemes tool options are reserved for partitioned (NovaScale 5xx5 Partitioned

Servers) or extended systems. See Configuring and Managing Extended Systems, on page

5-125.

Note:

Extended systems: this command will load all the NovaScale 5xx5 SMP Server domains adminstered by your PAP unit.

Viewing a Domain Configuration Scheme

Before loading a domain configuration scheme, you may want to know more about its scope.

To view a scheme:

1. Click Domain Manager to open the Control pane.

3-6 User's Guide

2. Click Schemes in the Toolbar to open the Schemes List dialog.

Figure 36. Schemes list dialog

3. Select the required Scheme from the list and click Preview to view scheme properties.

CellBlocks Shows the Central Subsystems included in the scheme and how they are partitioned into domains.

D Identifies physical partitions.

Domain Identities Shows the Identities allocated to each domain.

EFI LUNs

Data LUNs

Indicates the EFI LUNs used to boot each domain.

Indicates the Data LUNs used by each domain.

L

S

Indicates whether domain boot and data LUNs are linked to a fibre channel host. Reserved for systems connected to a SAN.

Indicates domain configuration status. A Green status icon indicates that the domain is configured correctly and is ready for use, a Red status icon indicates that the domain is not configured correctly and is not ready for use. If the status icon is Red, see Configuring Do-

mains, on page 5-28.

Figure 37. Scheme properties dialog - Example with 4 domains

Managing Domains 3-7

Loading a Domain Configuration Scheme

To power on server domains, you must first load the required Domain Configuration Scheme from the Domain Manager Control pane. Once the domain configuration scheme has been loaded, domains can be powered up simultaneously or independently.

To load a scheme:

1. Click Domain Manager to open the Control pane. If a scheme has not been previously loaded, you are invited to load one.

Note:

If the required scheme is already loaded, it is available for domain management.

If a scheme is already loaded, but is not the required scheme, see Adding Domains to the

Current Domain Configuration and Replacing the Current Domain Configuration below.

2. Click Schemes in the Toolbar to open the Schemes List dialog.

Figure 38. Schemes list dialog

3. Select the required Scheme from the list and click Preview to view scheme properties. See

Viewing a Domain Configuration Scheme, on page 3-6.

4. Click Apply. A dialog box informs you that the selected scheme will replace the current domain configuration.

5. Click Yes to confirm. All the domains included in the selected scheme are loaded in the

Control pane and are available for management.

3-8 User's Guide

If the domains are ready to be powered up, INACTIVE is displayed in the Domain State boxes. The Power On button becomes accessible once a domain has been selected.

Functional status icon &

CSS availability status indicator

GREEN

Operating System type

Select a domain to access the Power On button

Figure 39. Domain Manager control pane - Example with 4 domains

Note:

To display an Infotip listing the domain IP address, network name, cell composition and/or

EFI LUN, hover the mouse over the icon:

Figure 40. Domain Infotip

Managing Domains 3-9

Adding Domains to the Current Domain Configuration

A scheme can include domains from one or more Central Subsystems. More domains can be made available for domain management by adding one or more schemes to the current domain configuration.

Notes:

• New domains can only include resources that are INACTIVE in the current domain configuration.

• The current domain configuration can be partially replaced by first deleting INACTIVE domains and then adding a new domain scheme

• New domains must be configured via Configuration Tasks before they are available for domain management.

For further details, see

Configuring Domains, on page 5-28.

To add domains:

1. Click Domain Manager to open the Control pane.

2. Click Schemes in the Toolbar to open the Schemes List dialog.

3. Select the required Scheme from the list and click Preview to view scheme properties. See

Viewing Domain Configuration Schemes, on page 3-6.

4. Click Add. All the domains included in the scheme added are now available for management in the Control pane.

Replacing the Current Domain Configuration

Note:

All domains must be INACTIVE before the current domain configuration can be replaced.

To replace the current domain configuration:

1. Click Domain Manager to open the Control pane.

2. Check that all domains are INACTIVE. If a domain is not INACTIVE, it must be powered down before the current domain configuration can be replaced. See Powering OFF a

Domain, on page 3-18.

3. If required, save the current domain configuration. See Saving the Current Domain

Configuration Snapshot, on page 3-11.

4. Click Schemes in the Toolbar to open the Schemes List dialog.

5. Select the required scheme from the list and click Preview to view scheme properties. See

Viewing a Domain Configuration Scheme, on page 3-6.

6. Click Apply. A dialog box informs you that the selected scheme will replace the current domain configuration.

7. Click Yes to confirm. All the domains included in the selected scheme are loaded in the

Control pane and are available for management.

3-10 User's Guide

Saving the Current Domain Configuration Snapshot

Note:

Reserved for Customer Administrators.

You may want to save the current domain configuration, in particular if more than one scheme has been loaded and/or if you have modified domain configuration. When you save the current domain configuration, you create a new domain configuration scheme which is then available for domain management.

To save the current domain configuration snapshot:

1. Click Domain Manager to open the Control pane.

2. Click Save Snapshot. The Save Snapshot dialog opens.

Figure 41. Save Snapshot dialog

3. Enter a name and description for the new domain configuration scheme and click Save.

The Snapshot is now available as a scheme for domain management. For further details,

see Configuring Domains, on page 5-28.

Managing Domains 3-11

MyOperationsScheme Organization - NovaScale 5xx5 Partitioned Servers

Hardware Cell

Operating System

(customer-specific)

EFI LUN

**

IOC

QBBs

Domain KVM Ports

Domain Identity: MyOperations-1

Cell_0

Windows or Linux

*<MyServer>_0LU0 / <SAN>_LUN0

Module0_IOC0

Module0_QBB0

***CSS0_Mod0_IO0

Domain Identity: MyOperations-2

Cell_1 Hardware Cell

Operating System

(customer-specific)

EFI LUN

**

IOC

QBBs

Domain KVM Ports

Windows or Linux

*<MyServer>_0LU1 / <SAN>_LUN1

Module0_IOC1

Module0_QBB1

***CSS0_Mod0_IO1

Domain Identity: MyOperations-3

(NovaScale 5165 Partitioned Server)

Cell_2 Hardware Cell

Operating System

(customer-specific)

EFI LUN

**

IOC

QBBs

Domain KVM Ports

Windows or Linux

*<MyServer>_0LU2 / <SAN>_LUN2

Module1_IOC0

Module1_QBB0

***CSS0_Mod1_IO0

Domain Identity: MyOperations-4

(NovaScale 5165 Partitioned Server)

Cell_3 Hardware Cell

Operating System

(customer-specific)

EFI LUN

**

IOC

QBBs

Domain KVM Ports

Windows or Linux

*<MyServer>_0LU3 / <SAN>_LUN3

Module1_IOC1

Module1_QBB1

***CSS0_Mod1_IO1

* <MyServer> = default server name, e.g.: NS6085-0, NS6165-0

* <SAN> = default SAN name

** EFI LUN: xLUx = Local boot LUN device location (ModxLUIOx):

0LU0 = LUN device located in Module0_DIB0 or connected to Module0_IOC0

0LU1 = LUN device located in Module0_DIB1 or connected to Module0_IOC1

0LU2 = LUN device located in Module1_DIB0 or connected to Module1_IOC0

0LU3 = LUN device located in Module1_DIB1 or connected to Module1_IOC1

***CSSx = CSS number, Modx = Module number, IOx = IO box number

3-12 User's Guide

Operating System type is indicated by the Microsoft Windows or Linux logo in the

Domain Identities box.

Table 6.

MyOperations Scheme organization - NovaScale 5xx5 Partitioned Servers

Notes:

• In the screen shots, tables, and examples in this guide:

- MyOperationsScheme-xx is referred to as MyOperationsScheme

- MyOperations-xx-1 is referred to as MyOperations-1

- MyOperations-xx-2 is referred to as MyOperations-2

- MyOperations-xx-3 is referred to as MyOperations-3

- MyOperations-xx-4 is referred to as MyOperations-4

• xx in the default scheme and domain names represents the Central Subsystem HW identifier (from 00 to 16). For further details, refer to PMB LEDs and Code Wheels, on

page 4-50.

Managing Domains 3-13

Powering On a Domain

What You Can Do

During the domain power-on sequence, you can:

• View functional status

• View power logs

• View powering sequences

• View BIOS info

• View request logs

• View domain configuration, resources and status

Important:

Certain domain configuration and management tools are reserved for use with partitioned servers and extended systems. Please contact your Bull Sales Representative for sales information.

Once connected to the Customer's site power supply, the server initializes to the stand-by mode and the integrated PAP unit powers up. The server is not equipped with a physical power button and server domains are powered up from the PAM Domain Manager Control pane.

Check server functional status via the PAM Status Pane. If functional status is normal and the

CSS Availability bar is green, server domains can be powered up.

Notes:

• When more than one domain is loaded in the Control pane, domains can be powered up

sequentially or simultaneously. See Powering on a Single Domain, on page 3-14 and

Powering On Multiple Domains, on page 3-15.

• Server domains may be powered up even if the server presents a minor fault. See System

Functional Status, on page 4-4. However, you are advised to contact your Customer

Service Engineer so that the fault can be repaired.

Powering On a Single Domain

To power up a single domain:

NovaScale 5xx5 SMP Servers

1. Click Domain Manager to open the Control pane:

- If the domain is already loaded, it is available for domain management. Go to Step 2 below.

- If the domain is not already loaded, click Synchronize Domains in the toolbar to load the domain.

NovaScale 5xx5 Partitioned Servers

1. Click Domain Manager to open the Control pane:

- If the required domain configuration scheme is already loaded, the corresponding domain(s) are available for domain management. Go to Step 2.

- If a scheme has not been previously loaded, you are invited to select and load a

scheme. See Viewing a Domain Configuration Scheme, on page 3-6 and Loading a

Domain Configuration Scheme, on page 3-8.

3-14 User's Guide

- If a Scheme is already loaded, but is not the required Scheme, see Adding Domains to

the current Domain Configuration and Replacing the current Domain Configuration, on

page 3-10.

2. Select the required domain. If the domain is in the stand-by mode, INACTIVE is displayed in the Domain Status panel and the Power On button is accessible.

Important:

If INACTIVE is not displayed in the Domain Status panel and the Power On button is not accessible, check whether another user has already launched the power-up sequence on this domain. If the power-up sequence is not already in progress, see What To Do if an

Incident Occurs, on page 3-42.

3. Click Power On to power up the domain and associated hardware components. The

Power On Confirmation dialog opens.

4. Select the View Power-On Logs checkbox if you want power-on logs to be automatically displayed during the power-on sequence and click Yes to confirm.

Domain hardware is powered up from the stand-by mode to the main mode and the

Operating System is booted. As the power-on sequence progresses, power-on steps and domain state are displayed in the Domain Status panel, as shown in the following table.

Power On States

POWERING ON

POWERED ON - LOADING BIOS

BIOS READY - STARTING EFI

EFI STARTED - BOOTING OS

RUNNING

Table 7.

Power-on states

Once the Power On sequence has been successfully completed, RUNNING is displayed in the Domain Status panel and the Power Off, Reset and Force Power Off buttons become accessible.

For a detailed view of the Power On sequence, click Powering View in the Toolbar. See

Viewing Domain Powering Sequences, on page 3-32.

5. Repeat Steps 2 to 4 for each domain to be powered up.

Note:

If an error message is displayed in the Domain Status panel, the Power On sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

Powering On Multiple Domains

To power up more than one domain:

NovaScale 5xx5 SMP Servers

1. Click Domain Manager to open the Control pane:

- If the domains are already loaded, they are available for domain management. Go to

Step 2 below.

- If the domains are not already loaded, click Synchronize Domains in the toolbar to load all domains.

NovaScale 5xx5 Partitioned Servers

1. Click Domain Manager to open the Control pane:

Managing Domains 3-15

- If the required domain configuration scheme is already loaded, the corresponding domain(s) are available for domain management. Go to Step 2.

- If a scheme has not been previously loaded, you are invited to select and load a

scheme. See Viewing a Domain Configuration Scheme, on page 3-6 and Loading a

Domain Configuration Scheme, on page 3-8.

- If a Scheme is already loaded, but is not the required Scheme, see Adding Domains to

the current Domain Configuration and Replacing the current Domain Configuration, on

page 3-10.

2. Click Multiple Power. The Multiple Power Domains On/Off dialog opens.

Deselect All

Power On All

Power Off All

Cancels all selected operations.

Powers on all INACTIVE domains.

Powers off all RUNNING domains.

Force Power Off All Forcibly powers off all RUNNING or HUNG domains.

Deselect

Power On

Power Off

Force Power Off

Execute

Cancel

Cancels the selected operation for this domain.

Powers on this domain if INACTIVE.

Powers off this domain if RUNNING.

Forcibly powers of this domain if RUNNING or HUNG.

Applies all selected operations.

Cancels all selected operations.

Figure 42. Multiple power dialog - quadri-domain example

3. Click Power On All -> Execute or select the required domain Power On radio buttons and click Execute to simultaneously power on the selected INACTIVE domains and associated hardware components.

Domain hardware is powered up from the stand-by mode to the main mode and the

Operating System is booted. As the power-on sequence progresses, power-on steps and domain state are displayed in the Domain Status panel, as shown in the following table.

Power On States

POWERING ON

3-16 User's Guide

POWERED ON - LOADING BIOS

BIOS READY - STARTING EFI

EFI STARTED - BOOTING OS

RUNNING

Table 8.

Power-on states

Once the Power On sequence has been successfully completed, RUNNING is displayed in the Domain Status panel and the Power Off, Reset and Force Power Off buttons become accessible.

For a detailed view of the Power On sequence, click Powering View in the Toolbar.

See Viewing Domain Powering Sequences, on page 3-32.

Note:

If an error message is displayed in the Domain Status panel, the Power On sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

Managing Domains 3-17

Powering Off a Domain

What You Can Do

During the domain power-off sequence, you can:

• View functional status

• View power logs

• View powering sequences

• View BIOS info

• View request logs

View domain configuration, resources and status

Server domains can either be powered off from the Operating System (RECOMMENDED) or from the PAM Domain Manager, according to Operating System power settings.

The PAM Power Off command is a shutdown request to the Operating System. If the

Operating System is configured to accept a PAM power off request, it will save data, close open applications and shut down. Domain hardware will power down to the stand-by mode.

The Operating System may also be configured to request Operator confirmation before accepting a PAM power off request. Refer to the applicable documentation delivered with the

Operating System for further details.

Notes:

• When more than one domain is loaded in the Control pane, domains can be powered off

sequentially or simultaneously. See Powering Off a Single Domain, on page 3-18 and

Powering Off Multiple Domains, on page 3-19.

• Server domains may be powered up even if the server presents a minor fault. See System

Functional Status, on page 4-4. However, you are advised to contact your Customer

Service Engineer so that the fault can be repaired.

Powering Off a Single Domain

To power off a single domain from the PAM Domain Manager:

1. Click Domain Manager to open the Control pane.

2. Select the required domain. If the domain is in the powered-on mode, RUNNING is displayed in the Domain Status panel and the Power OFF button is accessible.

3. Click Power Off to power down the domain and associated hardware components. The

Power Off Confirmation dialog opens.

4. Select the View Power-Off Logs checkbox if you want power-off logs to be automatically displayed during the power-off sequence and click Yes to confirm.

The Operating System saves data, closes open applications and shuts down. Domain hardware is powered down from the main mode to the stand-by mode. As the power-off sequence progresses, power-off steps and domain state are displayed in the Domain

Status panel, as shown in the following table.

Power Off States

POWERING DOWN

INACTIVE

Table 9.

Power-off states

3-18 User's Guide

Once the Power Off sequence has been successfully completed, INACTIVE is displayed in the Domain Status panel and the Power On button becomes accessible.

For a detailed view of the Power Off sequence, click Powering View in the Toolbar. See

Viewing Domain Powering Sequences, on page 3-32.

5. Repeat Steps 2 to 4 for each domain to be powered down.

Note:

If an error message is displayed in the Domain Status panel, the Power Off sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

Powering Off Multiple Domains

To power off more than one domain from the PAM Domain Manager:

1. Click Domain Manager to open the Control pane.

2. Click Multiple Power. The Multiple Power Domains On/Off dialog opens.

Deselect All

Power On All

Power Off All

Cancels all selected operations.

Powers on all INACTIVE domains.

Powers off all RUNNING domains.

Force Power Off All Forcibly powers off all RUNNING or HUNG domains.

Deselect

Power On

Power Off

Force Power Off

Execute

Cancel

Cancels the selected operation for this domain.

Powers on this domain if INACTIVE.

Powers off this domain if RUNNING.

Forcibly powers of this domain if RUNNING or HUNG.

Applies all selected operations.

Cancels all selected operations.

Figure 43. Multiple power dialog - quadri-domain example

3. Click Power Off All → Execute or select the required domain Power Off radio buttons and click Execute to simultaneously power off the selected RUNNING domains and associated hardware components.

Managing Domains 3-19

The Operating System saves data, closes open applications and shuts down. Domain hardware is powered down from the main mode to the stand-by mode. As the power-off sequence progresses, power-off steps and domain state are displayed in the Domain

Status panel, as shown in the following table.

Power Off States

POWERING DOWN

INACTIVE

Table 10.

Power-off states

Once the Power Off sequence has been successfully completed, INACTIVE is displayed in the Domain Status panel and the Power On button becomes accessible.

For a detailed view of the Power Off sequence, click Powering View in the Toolbar. See

Viewing Domain Powering Sequences, on page 3-32.

Note:

If an error message is displayed in the Domain Status panel, the Power Off sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

3-20 User's Guide

Forcing a Domain Power Off

What You Can Do

During the domain force power-off sequence, you can:

• View functional status

• View power logs

• View powering sequences

• View BIOS info

• View request logs

• View domain configuration, resources and status

The Force Power Off command powers down domain hardware to the standby mode independently of the Operating System. This command should only be used if the Operating

System is not running or is not configured / not able to respond to a standard power off command.

Note:

A standard power off command is a shutdown request to the Operating System. Refer to the applicable documentation delivered with the Operating System for further details.

In the event of a critical fault, PAM software automatically forces a domain power off.

Notes:

• When more than one domain is loaded in the Control pane, domains can be forcibly powered off sequentially or simultaneously. See Forcibly Powering Off a Single Domain,

on page 3-22 and Forcibly Powering off Multiple Domains, on page 3-22.

• Server domains may be powered up even if the server presents a minor fault. See System

Functional Status, on page 4-4. However, you are advised to contact your Customer

Service Engineer so that the fault can be repaired.

Warning:

The Force Power Off command may result in domain data loss and file corruption. NEVER use the Force Power Off command if a RECOVERING BIOS error message is displayed. (The

BIOS recovery program automatically re-flashes the BIOS when certain problems occur during initialization).

Managing Domains 3-21

Forcibly Powering Off a Single Domain

To forcibly power off a single domain from the PAM Domain Manager:

1. Click Domain Manager to open the Control pane.

2. Select the required domain. If INACTIVE is NOT displayed in the Domain Status panel, the Force Power Off button is accessible.

3. Click Force Power Off to override the Operating System and forcibly power down the domain and associated hardware components without closing running applications and saving data. The Force Power Off Confirmation dialog opens.

4. Select the View Power-Off Logs checkbox if you want power-off logs to be automatically displayed during the power-off sequence and click Yes to confirm.

Domain hardware is powered down from the main mode to the stand-by mode. As the force power-off sequence progresses, power-off steps and domain state are displayed in the Domain Status panel, as shown in the following table.

Force Power Off States

POWERING DOWN

INACTIVE

Table 11.

Force power-off states

Once the Force Power Off sequence has been successfully completed, INACTIVE is displayed in the Domain Status panel and the Power On button becomes accessible.

For a detailed view of the Force Power Off sequence, click Powering View in the Toolbar.

See Viewing Domain Powering Sequences, on page 3-32.

5. Repeat Steps 2 to 4 for each domain to be forcibly powered down.

Note:

If an error message is displayed in the Domain Status panel, the Power Off sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

Forcibly Powering Off Multiple Domains

To forcibly power off more than one domain from the PAM Domain Manager:

1. Click Domain Manager to open the Control pane.

2. Click Multiple Power. The Multiple Power Domains On/Off dialog opens.

3-22 User's Guide

Deselect All

Power On All

Power Off All

Cancels all selected operations.

Powers on all INACTIVE domains.

Powers off all RUNNING domains.

Force Power Off All Forcibly powers off all RUNNING or HUNG domains.

Deselect

Power On

Power Off

Force Power Off

Execute

Cancel

Cancels the selected operation for this domain.

Powers on this domain if INACTIVE.

Powers off this domain if RUNNING.

Forcibly powers of this domain if RUNNING or HUNG.

Applies all selected operations.

Cancels all selected operations.

Figure 44. Multiple power dialog - quadri-domain example

3. Click Force Power Off All → Execute or select the required domain Force Power Off radio buttons and click Execute to to override the Operating System and forcibly power down the selected domains and associated hardware components without closing running applications and saving data.

Power Off States

POWERING DOWN

INACTIVE

Table 12.

Power-off states

Once the Power Off sequence has been successfully completed, INACTIVE is displayed in the Domain Status panel and the Power On button becomes accessible.

For a detailed view of the Power Off sequence, click Powering View in the Toolbar. See

Viewing Domain Powering Sequences, on page 3-32.

Note:

If an error message is displayed in the Domain Status panel, the Power Off sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

Managing Domains 3-23

Performing a Domain Memory Dump

The Dump command is used when the Operating System hangs and allows technicians to diagnose software problems by saving domain memory.

Warning:

The Dump command should only be used if the Operating System is not able to respond to a standard Power OFF command. The Dump command may result in domain data loss and file corruption.

The Dump command does not power down domain hardware (automatic warm reboot).

The Operating System must be configured to accept a dump command. Refer to the applicable documentation delivered with the Operating System for further details.

To perform a domain memory dump:

1. Click Domain Manager to open the Control pane.

2. Select the required domain. If RUNNING is displayed in the Domain Status panel, the

Dump button is accessible.

3. Click Dump to override the Operating System and dump domain core memory which will be copied to the server hard disk for analysis. The Dump Confirmation dialog opens.

4. Click Yes to confirm the Dump command.

The Dump sequence results in a warm reboot of the domain BIOS, EFI and Operating

System (without closing running applications and saving data).

As the dump sequence progresses, dump steps and domain state are displayed in the

Domain Status panel, as shown in the following table.

Dump States

POWERED ON - LOADING BIOS

BIOS READY - STARTING EFI

EFI STARTED - BOOTING OS

RUNNING

Table 13.

Dump states

Once the Dump sequence has been successfully completed, RUNNING is displayed in the

Domain Status panel and the Power Off, Reset and Force Power Off buttons become accessible.

5. Repeat Steps 2 to 4 for each domain on which you want to perform a memory dump.

Note:

If an error message is displayed in the Domain Status panel, the Dump sequence has failed.

See What To Do if an Incident Occurs, on page 3-42.

3-24 User's Guide

Manually Resetting a Domain

What You Can Do

During the domain reset sequence, you can:

• View functional status

• View power logs

• View powering sequences

• View BIOS info

• View request logs

• View domain configuration, resources and status

The Reset command is used to restart the current Operating System without powering off/on the domain.

Warning:

The Reset command should only be used if the Operating System is not running or is not able to respond to a standard Power Off command. The Reset command may result in domain data loss and file corruption. The Reset command does not power down domain hardware (warm reboot).

To manually reset a domain:

1. Click Domain Manager to open the Control pane.

2. Select the required domain. If INACTIVE is NOT displayed in the Domain Status panel, the Reset button is accessible.

3. Click Reset to override the Operating System and forcibly perform a warm reboot of the domain BIOS, EFI and Operating System without closing running applications and saving data. The Reset Confirmation dialog opens.

4. Click Yes to confirm the Reset command.

As the reset sequence progresses, reset steps and domain state are displayed in the

Domain Status panel, as shown in the following table.

Reset States

POWERED ON - LOADING BIOS

BIOS READY - STARTING EFI

EFI STARTED - BOOTING OS

RUNNING

Table 14.

Reset states

Once the Reset sequence has been successfully completed, RUNNING is displayed in the

Domain Status panel and the Power Off, Reset and Force Power Off buttons become accessible.

For a detailed view of the Reset sequence, click Powering View in the Toolbar. See

Viewing Domain Powering Sequences, on page 3-32.

5. Repeat Steps 2 to 4 for each domain to be reset.

Note:

If an error message is displayed in the Domain Status panel, the Power On sequence has

failed. See What To Do if an Incident Occurs, on page 3-42.

Managing Domains 3-25

Deleting a Domain

Notes:

• Reserved for Customer Administrators.

• The domain must be INACTIVE to be deleted.

Once loaded in the Domain Manager Control pane, a domain can be deleted from the current configuration. When the domain has been deleted, the corresponding resources can be re-allocated to another domain.

To delete a domain from the current configuration:

1. Click Domain Manager to open the Control pane.

2. Select the required domain.

3. Click Delete in the Command bar. The Confirm Remove Domain dialog opens.

Figure 45. Delete domain dialog - mono-module server

Figure 46. Delete Domain dialog - Example with 4 domains

4. Click Yes to confirm deletion of the selected domain from the current configuration.

3-26 User's Guide

An information box opens, informing you that the domain has been successfully deleted.

The domain is no longer visible in the Control pane.

Figure 47. Domain deleted information box

5. Click OK to continue.

Note:

Domain modifications are not automatically saved and are only applicable while the selected domain is loaded in the Domain Manager Control pane. If required, you can manually save the new configuration for future use. See Saving the Current Domain Configuration Snapshot,

on page 3-11.

Managing Domains 3-27

Viewing a Domain Fault List

The Domain Fault List page allows you to view messages about the faults encountered since the beginning of the last power-on sequence on the selected domain. The fault list is automatically cleared when a new domain power-on sequence is started.

Note:

For details about PAM messages, see Viewing and Managing PAM Messages, History Files

and Archives, on page 4-31.

To view the domain fault list:

1. Click Domain Manager to open the Control pane.

2. Select the required domain and click Fault List in the Command bar to open the Fault List dialog.

Button

Clear fault list

Help

Search

- String

- Contained in attribute

- Case sensitive

- Use previous results

+

Help on message

SV

ID

Target

String

Column Header

Local Time

Use

To manually clear the fault list.

To access context sensitive help.

To search for specific messages, according to:

- Alphanumeric identifier (ID), e.g. 2B2B2214 above.

- Message Source, Target, String, Data attributes.

- Upper case / lower case letters.

- Multiple search option used to search again from the results obtained from the previous search(es).

To view the message and access context sensitive help.

To view the related help message.

Use

To sort messages according to severity level.

To sort messages according to Message IDentifier.

To sort messages according to message local time and date.

To sort messages according to the component referred to in the message.

To sort messages according to message text string.

Figure 48. Domain fault list dialog - example

3-28 User's Guide

Viewing Domain Functional Status

The Domain Functional Status indicator in the Domain Manager Control pane shows the functional status of the last action performed on each domain, e.g. if the last Power ON/OFF sequence was successful, the indicator is green, and also reflects the status of domain hardware components.

As Customer Administrator, you can toggle the PAM Tree to display the synthetic functional status (round, colored indicator next to the Domain Manager node) of all the domains loaded in the Domain Manager Control pane. For example:

• If the last Power ON/OFF sequence was successful on all domains and the status of all domain hardware components is normal, the indicator is green

• If the last Power ON/OFF sequence failed on at least one domain and/or the status of at least one domain hardware component is fatal, the indicator is red.

Managing Domains 3-29

Indicator

Green

Yellow

Orange

Red

Status

NORMAL

WARNING

CRITICAL

FATAL

Explanation

Control Pane

The last command on this domain was successful.

or

The domain fault list has been cleared.

Note:

Domain functional status is reset to NORMAL when a new domain power-on sequence is started.

PAM Tree

The last command on all domains was successful.

or

All domain fault lists have been cleared.

Control Pane

An automatic Recovery command has been launched on this domain.

or

A WARNING status for a domain hardware component has been detected by the BIOS and a warning error has been added to the domain fault list.

or

The domain fault list was not empty when PAM was started.

PAM Tree

An automatic Recovery command has been launched on at least one domain.

or

A WARNING status for at least one domain hardware component has been detected by the BIOS and a warning error has been added to the domain fault list.

or

At least one domain fault list was not empty when PAM was started.

Note:

The BIOS recovery program automatically re-flashes the BIOS when certain problems occur during initialization

Control Pane

The last command on this domain was not successful and a critical error has been added to the domain fault list.

PAM Tree

The last command on at least one domain was not successful.

Control Pane

The last command on this domain has failed and a fatal error has been added to the domain fault list.

PAM Tree

The last command on at least one domain has failed.

Table 15.

Domain functional status indicators

3-30 User's Guide

Viewing Domain Power Logs

Power logs are recorded during domain power ON/OFF sequences. This information is

particularly useful for troubleshooting. See What To Do if an Incident Occurs, on page 3-42.

During a Power ON/OFF Sequence

1. Click Domain Manager to open the Control pane.

2. Select the required domain and launch the domain power ON/OFF sequence, as required.

3. Select the View Power Logs checkbox in the Power Confirmation dialog to automatically display power logs during the powering sequence.

Figure 49. Power logs dialog

Outside a Power ON/OFF Sequence

Click Powering View → Power Logs in the Domain Manager Toolbar.

Note:

Existing power logs are erased when a new power ON sequence is launched.

Managing Domains 3-31

Viewing Domain Powering Sequences

A detailed view of powering sequences can be displayed by clicking Powering View in the

Domain Manager Toolbar after a power request.

Status Panel Item

Domain

Central Subsystem

Domain State

Functional Status

Power Steps

Cell Composition

Explanation

Selected domain identity.

Name of the Central Subsystem containing the domain.

Current power sequence step.

Functional status of the last action performed on the domain.

See Viewing Domain Functional Status, on page 3-29.

Dynamic, graphic representation of power sequence steps.

Graphic representation of the core hardware elements in each cell (hardware partition): QBB(s), IOC(s) - Master / Slave.

See Configuring Domains, on page 5-28.

Figure 50. Powering view dialog

Note:

An Infotip can be obtained by hovering the mouse over the required element.

3-32 User's Guide

Viewing Domain BIOS Info

BIOS information is particularly useful for troubleshooting. See What To Do if an Incident

Occurs, on page 3-42.

To view BIOS information:

1. Click Domain Manager to open the Control pane.

2. Select the required domain.

3. Click Powering View -> BIOS Info in the Toolbar.

The BIOS Info dialog opens, displaying the following information:

- BIOS version used by the domain,

- BIOS boot post codes. See BIOS POST Codes.

4. Click Refresh to update BIOS information.

Figure 51. BIOS Info dialog

Managing Domains 3-33

Viewing Domain Request Logs

The Request Logs dialog gives direct access to a trace of major domain operations (requests) and indicates their initiators (requestors).

To view Request logs:

1. Click Domain Manager to open the Control pane.

2. Select the required domain.

3. Click Request Logs in the Command bar.

The Request Logs dialog displays the following information:

- Power On requests and requestors,

- Power Off requests and requestors,

- Reset requests and requestors.

Figure 52. Request Logs dialog

Note:

Existing request logs are erased when a new power ON sequence is launched.

3-34 User's Guide

Viewing Domain Configuration, Resources and Status

Note:

Certain features described below are only available if you are connected to a Storage Area

Network (SAN).

Please contact your Bull Sales Representative for sales information.

Information about the resources allocated to each domain is permanently accessible from the

Domain Manager Control pane:

• Graphic representation of domain configuration.

• Non-graphic summary of the hardware resources allocated to a domain.

• Graphic summary of the hardware resources allocated to a domain and their status.

Viewing Domain Configuration

1. Click Domain Manager to open the Control pane.

2. Select the required domain.

3. Click View in the Command bar to open the View Domain dialog.

Figure 53. View Domain dialog - example

Managing Domains 3-35

View Domain Dialog Items

Central Subsystem

Domain Identity

EFI LUN

Data LUNs

CPU

Domain Item

Memory

Composition

Module

Explanation

Name of the Central Subsystem containing the domain.

Logical name and profile given to the domain.

Boot LUN device location:

NovaScale 5xx5 SMP Server

0LU0 located in Module0_DIB0 or connected to Module0_IOC0

NovaScale 5085 Partitioned Server

0LU0 located in Module0_DIB0 or connected to Module0_IOC0

0LU1 located in Module0_DIB1 or connected to Module0_IOC1

NovaScale 5165 Partitioned Server

0LU0 located in Module0_DIB0 or connected to Module0_IOC0

0LU1 located in Module0_DIB1 or connected to Module0_IOC1

0LU2 located in Module1_DIB0 or connected to Module1_IOC0

0LU3 located in Module1_DIB1 or connected to Module1_IOC1

NovaScale 5245 Partitioned Server

0LU0 located in Module0_DIB0 or connected to Module0_IOC0

0LU1 located in Module0_DIB1 or connected to Module0_IOC1

0LU2 located in Module1_DIB0 or connected to Module1_IOC0

0LU3 located in Module1_DIB1 or connected to Module1_IOC1

0LU4 located in Module0_DIB0 / connected to Module2_IOC0

0LU5 located in Module0_DIB1 or connected to Module2_IOC1

NovaScale 5325 Partitioned Server

0LU0 located in Module0_DIB0 or connected to Module0_IOC0

0LU1 located in Module0_DIB1 or connected to Module0_IOC1

0LU2 located in Module1_DIB0 or connected to Module1_IOC0

0LU3 located in Module1_DIB1 or connected to Module1_IOC1

0LU4 located in Module0_DIB0 / connected to Module2_IOC0

0LU5 located in Module0_DIB1 or connected to Module2_IOC1

0LU6 located in Module1_DIB0 or connected to Module3_IOC0

0LU7 located in Module1_DIB1 or connected to Module3_IOC1

The Data LUNs allocated to this domain. Reserved for systems connected to a SAN.

Number of processors used by the domain.

Size of memory used by the domain.

Graphic representation of the main hardware elements used by the domain. See Note below.

Module housing the cell(s) used by the domain.

Module0 = Cell_0 and Cell_1

Module1 = Cell_2 and Cell_3

Module2 = Cell_4 and Cell_5

Module3 = Cell_6 and Cell_7

Figure 54. View Domain dialog 1/2

3-36 User's Guide

Cell

Domain Item Explanation

Cell(s) or hardware partition(s) used by the domain.

NovaScale 5085 SMP Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1

NovaScale 5165 SMP Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1

Cell_2 = Mod1_QBB0

Cell_3 = Mod1_QBB1

NovaScale 5245 SMP Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1

Cell_2 = Mod1_QBB0

Cell_3 = Mod1_QBB1

Cell_4 = Mod2_QBB0

Cell_5 = Mod2_QBB1

NovaScale 5325 SMP Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1

Cell_2 = Mod1_QBB0

Cell_3 = Mod1_QBB1

Cell_4 = Mod2_QBB0

Cell_5 = Mod2_QBB1

Cell_6 = Mod3_QBB0

Cell_7 = Mod3_QBB1

NovaScale 5085 Partitioned Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1, Mod0_IOC1, DIB1

NovaScale 5165 Partitioned Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1, Mod0_IOC1, DIB1

Cell_2 = Mod1_QBB0, Mod1_IOC0, DIB0

Cell_3 = Mod1_QBB1, Mod1_IOC1, DIB1

NovaScale 5245 Partitioned Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1, Mod0_IOC1, DIB1

Cell_2 = Mod1_QBB0, Mod1_IOC0, DIB0

Cell_3 = Mod1_QBB1, Mod1_IOC1, DIB1

Cell_4 = Mod2_QBB0, Mod2_IOC0, DIB0

Cell_5 = Mod2_QBB1, Mod2_IOC1, DIB1

NovaScale 5325 Partitioned Server

Cell_0 = Mod0_QBB0, Mod0_IOC0, DIB0

Cell_1 = Mod0_QBB1, Mod0_IOC1, DIB1

Cell_2 = Mod1_QBB0, Mod1_IOC0, DIB0

Cell_3 = Mod1_QBB1, Mod1_IOC1, DIB1

Cell_4 = Mod2_QBB0, Mod2_IOC0, DIB0

Cell_5 = Mod2_QBB1, Mod2_IOC1, DIB1

Cell_6 = Mod3_QBB0, Mod3_IOC0, DIB0

Cell_7 = Mod3_QBB1, Mod3_IOC1, DIB1

See Configuring Domains, on page 5-28.

Figure 55. View Domain dialog 2/2

Note:

When the domain is RUNNING, an Infotip identifying the Master QBB / IOC can be obtained by hovering the mouse over the QBB / IOC icons.

Master IOC = IOC to which the domain boot LUN device is connected (where applicable).

Master QBB = QBB required to start the domain.

Managing Domains 3-37

Viewing Domain Hardware Resources

1. Click Domain Manager to open the Control pane.

2. Select the required domain and click View Resources in the View Domain dialog to open the Domain Hardware Resources dialog.

Figure 56. Domain Hardware Resources dialog

For the selected domain, this dialog indicates:

- the number of QBBs, CPUs and IOCs allocated to the domain,

- the size of the Memory allocated to the domain,

- whether the processors used by this domain are in multithreading mode or monothreading mode :

YES for mutltithreading mode,

NO for monothreading mode.

Notes:Multithreading mode :

- If the domain is halted, YES / NO indicates whether the domain is configured for multithreading or monothreading.

- If the domain is running, YES / NO indicates whether the domain was launched in multithreading or monothreading mode.

Viewing Domain Details and Status

1. Click Domain Manager to open the Control pane.

2. Click View → View Resources → More Info... in the Command bar to open the Domain

Hardware Details dialog.

3-38 User's Guide

Figure 57. Domain Hardware Details dialog

Domain Hardware Details icons are explained in the following table.

Managing Domains 3-39

Item

Power Status

Icon Meaning

Main power is ON.

Green

Main power is OFF. Stand-by power is ON.

Red

Main power is OFF. Stand-by power is OFF

.

Pink

Blinking pink

Stand-by power is Faulty

.

Blinking red

Main power is Faulty.

Stand-by power may be ON, OFF or Faulty.

Main power status is Unknown.

Gray

Gray

Yellow/ red

To be logically included at the next domain power

ON.

To be logically excluded at the next domain power

ON.

To be functionally included in the domain (unlocked).

To be functionally excluded from the domain (locked).

Green

Used by the domain.

Not used by the domain.

Gray

Green

Physically present and accessible.

Red

Purple

Cannot be computed (detection circuit error).

Green

Yellow

Serious problem reported, no longer capable of

Orange shutdown request.

Red

Purple

Memory Board Memory available per QBB.

PCI slot occupied.

PCI slot empty.

Table 16.

Domain hardware details icons

3-40 User's Guide

Note:

When the domain is INACTIVE, the Domain Hardware Details dialog indicates the resources that PAM will try to initialize for the domain during the next Power ON sequence.

When the domain is RUNNING, the Domain Hardware Details dialog indicates the resources that PAM successfully initialized for the domain during the last Power ON or Reset sequence.

For more information about domain hardware, see:

Presence Status Indicators, on page 4-6

Functional Status Indicators, on page 4-8

Viewing Server Hardware Status, on page 4-14

Configuring Domains, on page 3-29

Excluding/Including Hardware Elements, on page 4-23

Limiting Access to Hardware Resources, on page 5-66

Managing Domains 3-41

What To Do if an Incident Occurs

When an incident occurs during a domain Power ON / Power OFF / Force Power OFF /

Reset sequence, a message is displayed in the Domain Status panel and a trace is recorded in the Domain POWER Logs. Table 17 indicates the messages that may be displayed during an incorrect power sequence.

SEQUENCE ERROR / INFORMATION MESSAGE

POWERING ON FAILED

TIMEOUT DURING POWER ON

POWERING ON SUSPENDED

DOMAIN HALTED

RECOVERING BIOS

BIOS LOADING TIMEOUT

BIOS READY - STARTING EFI TIMEOUT DURING START EFI

POWER DOWN FAILED

TIMEOUT DURING POWER DOWN

Table 17.

Domain power sequence error messages

PAM software also informs connected and non-connected users via:

• the PAM Web interface (Status Pane and/or User History files),

• e-mail (users with an appropriate Event Message subscription),

• an autocall to the Bull Service Center (according to your maintenance contract) for analysis and implementation of the necessary corrective or preventive maintenance measures, where applicable.

As Customer Administrator, you have access to the System History files and associated Help

Files. As Customer Operator, you have access to the User History and/or Web Event

Messages, and associated Help Files, pre-configured by your Customer Administrator.

You will find all the advice you need in the Help Files associated with the System / User

History and Web Event Messages you are authorized to view.

Whether you open a Web Event Message or a System / User History file, the resulting display and utilities are the same. See Viewing and Managing PAM Event Messages and

History Files, on page 4-31.

Note:

All incidents are systematically logged in the System History files, which you can view as

Customer Administrator at any time.

3-42 User's Guide

Dealing with Incidents

When you open the incident Help File, you may be requested to contact your Customer

Service Engineer or perform straightforward checks and actions:

Checking POST Codes

If you are requested to check POST Codes, see Viewing Domain BIOS Info, on page 3-33.

Checking Hardware Exclusion Status

If you are requested to check hardware exclusion status, see Excluding / Including Hardware

Elements, on page 4-23.

Checking Hardware Connections

If you are requested to check hardware connections, manually and visually ensure that all cables are correctly inserted in their corresponding hardware ports. See Cabling

Guide, 86 A1 34ER.

Rebooting Maestro / Resetting the PMB

If you are requested to reboot Maestro or to reset the PMB, see Checking, Testing, and

Resetting the PMB , on page 4-49.

Rebooting the PAP Application

If you are requested to reboot the PAP application:

1. From the Microsoft Windows home page, click Start -> Programs -> Administrative Tools

-> Component Services.

2. From Component Services, click Console Root -> Component Services -> Computers -> My

Computer -> COM+ Applications -> PAP.

3. Right click PAP to open the shortcut menu. Click Shutdown.

4. Activate the required PAM version to reboot the PAP application. See Deploying a PAM

Release, on page 5-23 and Activating a PAM Version, on page 5-24.

Powering OFF/ON the Domain

If you are requested to Power OFF/ON or Force Power OFF a domain, ensure that you have

saved data and closed open applications. See Powering ON a Domain, on page 3-14,

Powering OFF a Domain, on page 3-18, and Forcing a Domain Power OFF, on page 3-21.

Resetting a Domain

If you are requested to Reset a domain, see Manually Resetting a Domain, on page 3-25.

Performing a Domain Memory Dump

If you are requested to perform a domain memory Dump, see Performing a Domain Memory

Dump, on page 3-24.

Turning the Site Breaker Off

The server is not equipped with a physical power button and can only be completely powered down by turning the site breaker off.

Managing Domains 3-43

3-44 User's Guide

Chapter 4. Monitoring the Server

This chapter explains how, as Customer Administrator, you can supervise server operation and how as Customer Administrator and/or Operator you can view and manage PAM

Messages, Histories, Archives and Fault Lists. It includes the following topics:

Introducing PAM Monitoring Tools, on page 4-2

Using the Hardware Search Engine, on page 4-10

Viewing PAM Web Site User Information, on page 4-12

Viewing PAM Version Information, on page 4-13

Viewing Server Hardware Status, on page 4-14

Displaying Detailed Hardware Information, on page 4-15

Excluding / Including Hardware Elements, on page 4-23

Excluding / Including Clocks, SPS, XSP Links and Sidebands, on page 4-27

Managing PAM Messages, Histories, Archives and Fault Lists, on page 4-31

Viewing, Archiving and Deleting History Files, on page 4-36

What to Do if an Incident Occurs, on page 4-42

Creating an Action Request Package, on page 4-51

Creating a Custom Package, on page 4-54

Note:

Customer Administrators and Customer Operators are respectively advised to consult the

Administrator's Memorandum, on page xxv or the Operator's Memorandum, on page xxvii

for a detailed summary of the everyday tasks they will perform.

For further information about user accounts and passwords, see Setting up PAP Unit Users,

on page 5-17.

Monitoring the Server 4-1

Introducing PAM Monitoring Tools

Main Central SubSystem (CSS) hardware components are managed by the comprehensive

Platform Administration and Maintenance (PAM) software specifically designed for Bull

NovaScale Servers.

Note:

Peripheral devices such as disk racks, PCI adapters, KVM switch, local console, and the PAP unit are managed by the Operating System and/or by dedicated software.

For details on how to monitor these devices, please refer to the user documentation provided on the Bull NovaScale Server Resource CD-Rom.

PAM software permanently monitors and regulates CSS hardware during operation, ensuring automatic cooling for compliance with environmental requirements, power ON / OFF sequences, component presence and functional status checks, and event handling and forwarding.

In-depth monitoring is a Customer Administrator function and the PAM Hardware Monitor is only available to users with administrator access rights. However, all connected users are permanently and automatically informed of CSS functional status via the PAM Status pane and of domain status via the PAM Domain Manager Control pane.

The PAM Event Messaging system offers comprehensive event message subscription options allowing both connected and non-connected users to be informed of server status. See

Customizing the PAM Event Messaging System, on page 5-133 for details.

To refresh the PAM display:

• Click the Refresh Tree button in the PAM Tree toolbar to refresh the PAM Tree.

• Click a node in the PAM Tree to refresh the corresponding Control pane display.

• Click the Refresh Web Page button to return to the PAM Home Page.

Note:

DO NOT use the Refresh option obtained by right clicking the mouse in the browser window.

4-2 User's Guide

Viewing System / Component Status

What You Can Do

• Check system status

• Check CSS module availability status

Check event message status

• View hardware presence status

View hardware functional status

• View server hardware status

• View FRU information

• View firmware information

• View thermal status

• View power status

• View temperature status

• View fan status

• View jumper status

• View PCI slot status

PAM Status Pane

When you log onto the PAM Web site, you are able to check system status at a glance via the Status pane which provides quick access to CSS Module availability status, server functional status, and pending event message information.

A System Functional Status icon

B Presence/Functional Status toggle button

C Event Message Viewer

D Pending Event Message icon

Figure 58. PAM Status pane

E CSS Availability Status icon

F Event Message Severity icon

G New Event Message icon

Monitoring the Server 4-3

CSS Availability Status

The CSS availability status bar reflects the operational status of the data link(s) between the

Platform Management Board (PMB) embedded in each CSS Module and the PAP Unit. Each

CSS module is represented by a zone in the status bar.

• When a CSS Module PMB is detected as PRESENT, the corresponding zone in the status bar is GREEN.

• When a CSS Module PMB is detected as ABSENT, the corresponding zone in the status bar is RED.

• When you hover the mouse over the status bar, an Infotip displays the presence status of

CSS Module PMB - PAP Unit data links.

The following figure represents the status bar for a bi-module server. One CSS Module PMB is detected as PRESENT and the other is detected as ABSENT.

A: Bar red (CSS Module_0 not available)

Figure 59. CSS Module availability status bar

System Functional Status

If the system is operating correctly, the System Functional Status icon is green. Table 18.

explains possible system functional status indications.

Icon Status

NORMAL

Explanation

No problem detected. The system is operating correctly.

Green

WARNING Minor problem reported. The system is still operational.

Yellow

Orange

Serious problem reported. The system is no longer capable of operating correctly. PAM may generate an OS shutdown request.

Major problem reported. PAM may automatically shut down the OS. The system is partially or totally stopped.

Red

NOT ACCESSIBLE Status cannot be computed (detection circuit error).

Purple

Table 18.

CSS hardware functional status icons

Important:

If the system functional status icon and/or CSS availability status bar is/are not green, see

What to Do if an Incident Occurs, on page 4-42.

Event Message Status

The New Event Message icon informs you that new messages have arrived and that you can click the View Event Message icon to view them (the number of unprocessed event messages is also displayed). See Managing Event Messages, Hardware Faults and History/Archive

Files, on page 4-31

The Event Message Severity icon indicates the set maximum severity level of unprocessed

event messages. See Understanding Message Severity Levels, on page 4-32.

4-4 User's Guide

PAM Tree Pane

As Customer Administrator, you can view the presence and functional status of each hardware element from the PAM Tree pane. The PAM Tree pane is refreshed at your request.

Use the Refresh PAM Tree button to update the display when required.

Important:

To maintain a trace of transient faults, PAM Tree functional and/or presence status indicators will not change color until the domain has been powered OFF/ON, even if the error has been corrected.

Displaying Presence Status

When, as Customer Administrator, you log onto the PAM Web site, server hardware presence status is displayed in the PAM Tree by default (square, colored indicator next to the

Hardware Monitor node). If you expand the PAM Tree, the presence status of all hardware elements is displayed.

1

2

Expand PAM Tree button

Presence status indicators

Figure 60. PAM Tree hardware presence status display

Monitoring the Server 4-5

When hardware presence status is normal, all presence status indicators are green.

The following table explains possible hardware presence status indications.

Presence Status Indicators

Indicator Status Explanation

Green

Red

Red/white

This hardware element: disappeared.

A sub-component of this hardware element: disappeared.

Purple

Purple/white

MISSING AND

NOT ACCESSIBLE

A sub-component of this hardware element:

- was present in a previous configuration but has disappeared.

Purple/red

A sub-component of this hardware element:

- cannot be computed (detection circuit error).

Table 19.

Hardware presence status indicators

Important:

If a PAM Tree hardware presence status indicator is not green, this could be normal if a hardware element has been removed for maintenance. See What to Do if an Incident Occurs,

on page 4-42.

4-6 User's Guide

Displaying Functional Status

You can toggle the PAM Tree to view system / hardware functional status (round, colored indicator next to the Hardware Monitor node). If you expand the PAM Tree, the functional status of all hardware elements is displayed.

Functional Status is a composite indicator summarizing Failure Status, Fault Status,

Power Status, and Temperature Status indicators, where applicable.

1

2

3

Presence/Functional status toggle button

Expand PAM Tree button

Functional status indicators

Figure 61. PAM Tree functional status display

Monitoring the Server 4-7

When hardware functional status is normal, all functional status indicators are green.

Table 20. explains possible hardware functional status indications.

Functional Status Indicators

Indicator Status

Green

Explanation

No problem detected. This hardware element is operating correctly.

Yellow

Purple

Minor problem reported. This hardware element is still operational.

Serious problem reported. This hardware element is no longer capable of operating correctly. PAM may generate an OS shutdown request.

Major problem reported. PAM may automatically shut down the OS. System integrity is jeopardized.

The functional status of this hardware element cannot be computed (detection circuit error).

Table 20.

Hardware functional status indicators

Important:

To maintain a trace of transient faults, PAM Tree functional and/or presence status indicators will not change color until the domain has been powered OFF/ON, even if the error has been corrected. Overall server functional status is indicated by the system Functional Status icon in the Status pane. For further details, see What to Do if an Incident Occurs, on page

4-42.

Note:

If, when you toggle the PAM Tree to view hardware functional status, the functional status of a hardware element is not normal, the Hardware Monitor node will automatically expand to the level of the malfunctioning hardware element, as shown in Figure 62.

4-8 User's Guide

1

2

Functional status: Warning

PAM Tree automatically expanded to faulty CPU

Figure 62. PAM Tree - automatically expanded functional status display

Monitoring the Server 4-9

Using PAM Utilities

What You Can Do

• Search for excluded hardware elements

• Search for missing hardware elements

• View PAM Web site information

• View PAM version information

• Exclude / include hardware elements

Using the Hardware Search Engine

The Hardware Search engine allows you to search for and view hardware elements corresponding to selected criteria, for example Excluded or Missing hardware elements.

Notes:

• Excluded hardware elements are those that have been logically excluded from the server.

See Excluding / Including Hardware Elements, on page 4-23.

• Missing hardware elements are those that have been physically removed from the server

(e.g. for maintenance).

To search for specific hardware:

1. Click Hardware Monitor in the PAM tree to open the Hardware Search page.

Figure 63. Hardware Search engine

2. Select the required search criteria from the dropdown box and click OK.

4-10 User's Guide

3. Once the search is complete, results are displayed in the control pane.

Figure 64. Hardware Search result list (example)

Monitoring the Server 4-11

Viewing PAM Web Site User Information

As Customer Administrator, you can view the list of PAM users currently logged onto the PAM

Web site by clicking Hardware Monitor → PAM Web Site.

The Web site version and a list of connected users and session details are displayed in the

Control pane. The current session is indicated by the icon.

Note:

You can view user roles by selecting a user and clicking View Roles in the toolbar.

The roles associated with this user are displayed in the Roles for selected session dialog.

Figure 65. PAM Web Site user information

4-12 User's Guide

Viewing PAM Version Information

PAM version information may be useful to help your Customer Service Engineer solve software-related problems.

To view PAM version, site data and release data, click Hardware Monitor → PAP. The PAP

Unit Information Control pane opens, indicating PAM software version details along with

PAM Site Data and Release Data directory paths:

• the PAM Release Data directory is used for all the files delivered as part of PAM software to ensure configuration consistency.

• the PAM Site Data directory is used for all the the files produced by PAM software (history files, configuration files) concerning Customer site definition and activity.

To view complete PAM resource file information, click More Info. The PAM Versions dialog opens.

Figure 66. PAP unit information

If you want to deploy a new PAM release or activate another PAM version, see Deploying a

New PAM Release, on page 5-23 and Activating a PAM Version, on page 5-24.

Monitoring the Server 4-13

Viewing Server Hardware Status

When you click the CSS Name in the PAM tree (e.g. MYSERVER in the figure), the Hardware

Monitor displays a visual representation of the presence and functional status of CSS module components in the Control pane. Each primary hardware element functional status indicator is a clickable hotspot leading directly to the detailed Hardware Status page.

1

2

3

4

5

Presence status (default display)

Presence/Functional status Tree Toggle

CSS name

Functional status (after toggle)

Clickable hotspots

Figure 67. PAM Hardware Monitor

As you click a hardware element hotspot in the Control pane, you will notice that the PAM

Tree automatically expands to the selected component level.

Note:

If a component is not part of your configuration, it is grayed out in the display.

If a component is part of your configuration but has been detected as "missing", it is displayed in red.

The meanings of presence and functional status indicators are explained in Table 19.

Presence Status Indicators, on page 4-6 and Table 20.Functional Status Indicators, on page

4-8.

Important:

If a functional status indicator is not green, see What to Do if an Incident Occurs, on

page 4-42.

4-14 User's Guide

Viewing Detailed Hardware Information

For detailed information about module / component / sub-component status, you can either click the corresponding hotspot in the Hardware Monitor Control pane or click the required hardware element in the PAM Tree to open the Hardware Status page.

General Tab

The General tab gives access to the following information:

Presence Status

Functional Status

Failure Status

Fault Status

Display Fault List

Exclusion Request

Indicates if the hardware element is physically present and correctly

configured. See Presence Status Indicators, on page 4-6.

Indicates if the hardware element is functioning correctly.

See Displaying Functional Status, on page 4-7.

NOTE:

Functional Status is a composite indicator summarizing Failure

Status, Fault Status, Power Status, and Temperature Status indicators, where applicable.

Indicates if a failure has been detected on the hardware element.

NOTE:

This feature is reserved for future use.

See Failure Status Indicators, on page 4-16.

Indicates if a fault has been detected on the hardware element.

See Fault Status Indicators, on page 4-16.

When a hardware fault is detected, a fault message is generated and the Display Fault List button gives direct access to the list of faults recently encountered by this hardware element.

See Managing PAM Messages, Histories, Archives and Fault Lists,

on page 4-31 ..

The Exclusion Request checkbox is used to logically exclude/include hardware elements from the domain at the next power-on.

See Excluding / Including Hardware Elements, on page 4-23.

Note:

The CSS Module Hardware Status page also indicates CSS module clock frequency.

Figure 68.

General Hardware Status page (example)

Monitoring the Server 4-15

Failure Status Indicators:

Indicator

Green

Orange

Red

NORMAL

Status

DEGRADED

FAILED

UNKNOWN

Explanation

PAM software has detected no failures on this hardware element.

PAM software has detected that this hardware element is running at sub-standard capacity but is not jeopardizing system performance.

PAM software has detected a failure that may be jeopardizing system performance.

PAM software is not receiving diagnostic information from this hardware element.

Gray

Fault Status Indicators

Fault Status, accessible via the General tab,

Indicator Status Explanation

Green

NORMAL

PAM software has detected no faults on this hardware element.

Red

FAULTY

UNKNOWN

Gray

Table 21.

Fault status indicators

PAM software has detected 1 or more fault(s) on this hardware element.

PAM software is temporarily meaningless (e.g. hardware element missing).

FRU Info Tab

The FRU Info tab gives access to Field Replaceable Unit identification data for the hardware element, such as Manufacturer's name, product name, part number, ... .

Figure 69. FRU data (example)

Note:

When two Internal Peripheral Drawers are inter-connected to house 4 SCSI RAID disks, 1

DVD-ROM drive, 1 USB port, the FRU Info tab indicates Chained DIBs in the FRU to order field.

4-16 User's Guide

Firmware Tab (Core MFL & PMB only)

The Firmware tab gives access to firmware version data for the hardware element.

Note:

Firmware versions may differ.

Figure 70. Firmware data (example)

Thermal Zones (CSS module only)

Thermal Zones, accessible via the Thermal zones tab, shows the thermal zones monitored by

PAM software. A cooling error in a thermal zone will affect all the hardware elements in that

zone. See Displaying Functional Status, on page 4-7.

Figure 71. CSS module thermal zone details

Monitoring the Server 4-17

Power Tab

The Power tab gives access to power status data for the hardware element, indicating main and standby power state and/or power-specific faults for each converter. See Displaying

Functional Status, on page 4-7.

Once connected to the Customer's site power supply, server hardware elements initialize to the stand-by mode. Server hardware elements initialize to the main mode when the domain is powered up.

Measured values

Nominal values

Figure 72. Converter power status details (example)

Indicator Status

MAIN POWER ON

Green

Explanation

STANDBY POWER ON

Green

MAIN POWER OFF

White

STANDBY POWER OFF

White

Red

MAIN POWER

FAULT/FAILED

PAM software has detected 1 or more main / standby power fault(s) on this hardware element.

Red

STANDBY POWER

FAULT/FAILED

Gray

Gray

MAIN POWER

MISSING/UNKNOWN

STANDBY POWER

MISSING/UNKNOWN

PAM software cannot read main / standby power status on this hardware element.

Table 22.

Power tab status indicators

4-18 User's Guide

CSS Module Power Tab

The Power tab gives access to power status data for the CSS module DPS units.

48V Presence

PRESENT

ABSENT

Not Found

48V Value

Meaning

At least 1 DPS unit is ON.

All DPS units are OFF.

PAM software cannot read CSS module power status.

Current intensity in Amperes (varies according to configuration).

Figure 73. CSS module power status details

Monitoring the Server 4-19

Temperature Tab

The Temperature tab gives access to temperature status data for the hardware element, indicating overtemperature or temperature-specific faults.

Figure 74. Temperature probe status details (example)

Indicator Status Explanation

NORMAL Hardware element temperature is normal.

Green

Yellow

WARNING

PAM software has detected a rise in temperature on this hardware element, but it is still operational and is not jeopardizing system performance.

CRITICAL

PAM software has detected a critical rise in temperature on this hardware element. PAM will generate an OS shutdown request.

Orange

Red

FATAL

PAM software has detected a fatal rise in temperature on this hardware element. PAM will automatically shut down the OS.

Gray

UNKNOWN

PAM software cannot read temperature status on this hardware element.

Table 23.

Temperature tab status indicators

4-20 User's Guide

Fan Status (Fanboxes only)

Fan Status, accessible via the Fans tab, indicates fan status, speed and supply voltage. See

Displaying Functional Status, on page 4-7.

During normal operation, the display depicts fan rotation.

Each fanbox is equipped with 2 hot-swap, redundant, automatically controlled fans.

Note:

If all fans are halted in the display, check that your browser allows you to play animations in

Web pages.

Figure 75. Fanbox details (example)

Jumper Status (IOC only)

Reserved for Customer Service Engineers.

Jumper Status, accessible via the Jumpers tab, indicates the current position of BIOS

Recovery, ClearCMOS, and ClearPassword jumpers. Reserved for Customer Service

Engineers.

Figure 76. IO Box jumpers tab

Monitoring the Server 4-21

PCI Slots (IOC only)

PCI Slot Status, accessible via the PCI Slots tab, shows PCI board type and the functional and power status of PCI slots at the last domain power-on. PCI-Express boards are indicated by a

symbol.

Power status indicators

Figure 77. PCI slot status

Clicking a PCI board gives access to PCI Slot Details: such as Minor and Signal status,

Logical, Bus and Device numbers, Bus and Board frequencies, Vendor, Device and Revision identifiers, Susbsystem Vendor and Device identifiers and Class code.

Figure 78. PCI slot details dialog (example)

4-22 User's Guide

Excluding / Including Hardware Elements

As Customer Administrator, if a redundant hardware element is faulty, you can logically

Exclude it from the domain until it has been repaired or replaced. To be taken into account, exclusion requires domain power OFF/ON.

A complete list of logically excluded hardware elements can be obtained via the Hardware

Monitor search engine. See Using the Hardware Search Engine, on page 4-10.

Important:

Hardware elements must be excluded with care. The exclusion of non-redunda4nt hardware elements will prevent the server domain from booting. Exclusion guidelines are given in the

Hardware exclusion guidelines table, on page 4-25.

Excluding a Hardware Element

Important:

The exclusion of a hardware element is only taken into account at the next domain power

ON. A complete list of logically excluded hardware elements can be obtained via the

Hardware Monitor search engine.

See

Using the Hardware Search Engine, on page 4-10.

1. Check that the hardware element is "excludable" and that exclusion will not affect

domain availability. See Hardware Exclusion Guidelines, on page 4-25 .

2. Click the required hardware element in the PAM Tree to open the Hardware Status page.

Exclusion request checkbox: select to exclude

Figure 79. Inclusion

3. Select the Exclude checkbox and click Apply. The Exclude dialog box opens.

4. Click Yes to confirm exclusion of the selected hardware element. Exclusion will be taken into account at the next domain power ON.

Monitoring the Server 4-23

Notes:

• If you want to check domain hardware status, click Domain Manager → Resources →

More info... to open the Domain Hardware Details page.

• Hardware components to be logically excluded from the domain at the next domain power ON are marked with a red / yellow icon in the Lock Request column in the

Domain Hardware Details page.

See Viewing Domain Configuration, Resources and Status, on page 3-35.

Including a Hardware Element

Important:

The inclusion of a hardware element is only effective once the domain has been powered

OFF/ON.

1. Click the required hardware element in the PAM Tree to open the Hardware Status page.

Exclusion request checkbox: deselect to include

Figure 80. Example Hardware Status page

2. Deselect the Exclude checkbox and click Apply. The Include dialog box opens.

3. Click Yes to confirm inclusion of the selected hardware element. Inclusion will be taken into account at the next domain power ON.

Notes:

• If you want to check domain hardware status, click Domain Manager → Resources →

More info... to open the Domain Hardware Details page.

• Hardware components to be logically included in the domain at the next domain power

ON are marked with a gray icon in the Exclusion Request column in the Domain

Hardware Details page.

See Viewing Domain Configuration, Resources and Status, on page 3-35.

4-24 User's Guide

Hardware Exclusion Guidelines

Hardware Element Exclusion Guidelines

IMPORTANT:

If the following hardware elements are excluded, the corresponding server domain will not power up:

• Master IOC, Master IOC HubLink 1, Master IOC PCI Slots 1 & 2, Master IOL

Note:

When a domain comprises more than one cell (therefore more than one IOC), the Master

IOC is the one hosting the boot disk. The other IOCs in the domain are Slave IOCs.

IOC • Slave IOCs can be safely excluded from a domain, but connected peripherals will no longer be accessible.

• If the Master IOC is excluded from a domain, the domain will not power up.

IOC HubLink

PCI Slot

IOL

DIB

• All IOC HubLinks not connected to a boot disk can be safely excluded from a domain, but connected peripherals will no longer be accessible.

IOC HubLinks are organized as follows:

HubLink_1 controls PCI Slots 1 & 2 (Master IOC boot disk)

HubLink_2 controls PCI slots 3 & 4

HubLink_3 controls PCI slots 5 & 6

Note:

If Master IOC HubLink_1 is excluded, the domain will not power up.

• All PCI slots not connected to a boot disk can be safely excluded from a domain, but connected peripherals will no longer be accessible.

Note:

If Master IOC PCI Slots 1, 2 are excluded, system disks will no longer be accessible and the domain will not power up.

• Slave IOLs can be safely excluded from a domain, but connected peripherals will no longer be accessible.

Note:

If the Master IOL is excluded, the domain will not power up.

• A DIB can be safely excluded from a domain if it does not house the boot disk.

• In Chained DIB configuration, if you exclude one DIB, the other DIB will also be automatically excluded.

Note:

If a DIB housing a boot disk is excluded, the system disk will no longer be accessible and the domain will not power up.

Table 24.

Hardware exclusion guidelines - 1

Monitoring the Server 4-25

QBB

Hardware Element

Memory Rows

CPU

SPS

Clock

DPS Unit

Fanbox

Exclusion Guidelines

• At least one QBB must be "included" in a domain.

• At least one Memory Row must be "included" in a QBB.

• At least one CPU must be "included" in a QBB.

Note:

If all CPUs are excluded from a QBB, the QBB itself is excluded.

• At least one SPS must be "included" in a Core Unit.

Note:

If all SPS are excluded from a Core Unit, the domain will not power up.

• At least one Clock must be "included" in a Core Unit.

• Only one DPS unit can be safely excluded at a given time.

• Only one Fanbox can be excluded from a domain at a given time.

Note:

If more than one Fanbox is excluded, the domain may not power up.

Table 25.

Hardware exclusion guidelines

4-26 User's Guide

Excluding / Including Clocks, SPS, XSP Cables and Sidebands

PAM software automatically manages and optimizes server ring connections. There are four types of ring connections:

• Clocks

• SPS

• XSP cables

• Sidebands (dedicated to error and reset logs)

In the event of a failure, your Customer Service Engineer may request you to logically exclude a clock, SPS, XSP cable and/or sideband until the failure has been repaired.

Excluding / Including Clocks

For high flexibility, availability and optimum performance, each CSS module is equipped with two clocks (one on each Core unit MSX board). Only one clock is required per domain.

If a clock is faulty, you can logically exclude it to ensure correct server operation until replaced. Once the fault has been repaired, you can logically include the excluded clock.

To logically exclude / include a clock:

1. From the PAM Tree pane, click Configuration Tasks → Ring Exclusion to open the Control pane.

2. Select the Clock tab to display current server clock configuration.

Figure 81. Ring exlcusion control pane - clock tab

Monitoring the Server 4-27

3. Select the required clock(s) by clicking the corresponding icon or table entry.

4. Click Save in the Tool bar to logically exclude / include the clock at the next power-on.

Note:

The legend at the bottom of the Control pane explains different clock states.

In the above figure, no exclusions have been requested / applied.

Excluding / Including SPS

For high flexibility, availability and optimum performance, each CSS module is equipped with two SPS for inter-module communication (one on each Core unit MSX board). Only one inter-module communicaiton link is required per domain. If an SPS is faulty, you can logically exclude it to ensure correct server operation until replaced. Once the fault has been repaired, you can logically include the excluded SPS.

To logically exclude / include an SPS:

1. From the PAM Tree pane, click Configuration Tasks → Ring Exclusion to open the Control pane.

2. Select the SPS tab to display SPS configuration.

Figure 82. Ring exclusion control pane - SPS tab

3. Select the required SPS by clicking the corresponding icon or table entry.

4. Click Save in the Tool bar to logically exclude / include the SPS at the next power-on.

Note:

The legend at the bottom of the Control pane explains different SPS states.

In the above figure, no exclusions have been requested / applied.

4-28 User's Guide

Excluding / Including XSP Cables

For high flexibility, availability and optimum performance, each CSS module is equipped with two XSP cables for inter-module communication. Each XSP cable routes SPS data and clock signals. If an XSP cable is faulty, you can logically exclude it to ensure correct server operation until replaced. Once the fault has been repaired, you can logically include the excluded XSP cable.

To logically exclude / include an XSP cable:

1. From the PAM Tree pane, click Configuration Tasks → Ring Exclusion to open the Control pane.

2. Select the XSP cables tab to display XSP configuration.

Figure 83. Ring exclusion control pane - XSP cable tab

3. Select the required XSP cable by clicking the corresponding icon or table entry.

4. Click Save in the Tool bar to logically exclude / include the selected XSP cable(s) at the next power-on or click the Include all XSP cables and Save button at the bottom of the page to logically include ALL previously excluded XSP cables at the next power-on.

Note:

The legend at the bottom of the Control pane explains different XSP cable states.

In the above figure, no exclusions have been requested / applied.

Monitoring the Server 4-29

Excluding / Including Sidebands

The sidebands route reset and error logs. If a sideband is faulty, you can logically exclude it to ensure correct server operation until replaced. Once the fault has been repaired, you can logically include the excluded sideband.

To logically exclude / include a sideband:

1. From the PAM Tree pane, click Configuration Tasks → Ring Exclusion to open the Control pane.

2. Select the Sideband tab to display sideband configuration.

Figure 84. Ring exclusion control pane - sideband tab

3. Select the required sideband by clicking the corresponding icon or table entry.

4. Click Save in the Tool bar to logically exclude / include the sideband at the next power-on.

Note:

The legend at the bottom of the Control pane explains different sideband states.

In the above figure, no exclusions have been requested / applied.

4-30 User's Guide

Managing PAM Messages, Histories, Archives and Fault Lists

What You Can Do

• View Web event messages

• Acknowledge Web event messages

• Sort and locate Web event messages

• View e-mailed event messages

• Display the hardware faults list

• View history files online

• View archive files online

• View history files offline

• View archive files offline

• Manually archive history files

• Manually delete archive files

A comprehensive set of Event Message subscriptions allows connected and non-connected users to be notified of system status and activity. Pre-defined Event Message Subscriptions forward event messages for viewing/archiving by targeted individuals and/or groups, with an appropriate subscription, via:

• the PAM Web interface (connected Customer Administrator / Operator),

• User History files (connected Customer Administrator / Operator),

• e-mail (non-connected recipients - Customer Administrator / Operator / other)

• SNMP traps (non-connected recipients - Customer Administrator / Operator / other),

• an autocall to the Bull Service Center (according to your maintenance contract).

Note:

Subscriptions can be customized to suit your working environment.

For further details, see Customizing the PAM Event Messaging System, on page 5-133.

Monitoring the Server 4-31

Understanding PAM Message Severity Levels

Messages are graded into four severity levels as shown in the following table.

Icon Severity Level

SUCCESS

Explanation

An action requested by a user has been performed correctly or a function has been completed successfully.

Information message, for guidance only.

INFORMATION System operation is normal, but status has changed.

Information message, for guidance and verification.

WARNING

ERROR

An error has been detected and overcome by the system or a processed value is outside standard limits (e.g.

temperature).

System operation is normal, but you are advised to monitor the hardware concerned to avoid a more serious error.

See What to Do if an Incident Occurs, on page 4-42.

An error has been detected and has not been overcome by the system.

System integrity is jeopardized. Immediate action is required.

See What to Do if an Incident Occurs, on page 4-42.

Table 26.

Message severity levels

During normal operation, messages will be marked with the SUCCESS or INFORMATION icon.

Note:

A single message may have different severity levels. For example, the message <Unit

absent> may be the result of a:

• Presence Status request, indicating component status (information level).

• Action request, indicating an error. The command cannot be executed because the component is absent (error level).

Important:

If a message is marked with the WARNING or ERROR symbol, see What to Do if an Incident

Occurs, on page 4-42.

4-32 User's Guide

Viewing PAM Messages and Fault Lists

Whether you consult a Web Event Message, a Faults List, a System / User History or Archive, the resulting display and utilities are the same.

Access to Help Message

Button Use

Acknowledge selected events To remove viewed messages from the pending event list.

Select all events

Unselect all events

To select all Ack checkboxes.

To deselect all Ack checkboxes.

Help

Search

- String

- Contained in attribute

- Case sensitive

Reset

Ack

+

To access context sensitive help.

To search for specific messages, according to:

- Alphanumeric identifier (ID), e.g. 2B2B2214 above.

- Message Source, Target, String, Data attributes.

- Upper case / lower case letters.

To delete the current search history.

To select the message for acknowledgement.

To view the message and access context sensitive help.

Help on message

Type

ID

Column Header*

To view the related help message.

Use

To sort messages according to severity level.

Local Time

Target

String

To sort messages according to Message IDentifier, e.g.

2B2B2214 above.

To sort messages according to message local time and date.

To sort messages according to the component referred to in the message.

To sort messages according to message text string.

* Double click the column header to sort messages

Figure 85. Display Events page

Monitoring the Server 4-33

Specimen Message Help File

The Help File explains the message and indicates related actions, where applicable, as shown in Figure 86.

Figure 86. Specimen message help file

Viewing and Acknowledging PAM Web Event Messages

To view Web event messages:

1. From the Status pane, click the icon to open the Display Events page. See Figure 85.

Display Events page, on page 4-33.

2. Click the + sign to expand the required message.

3. Click the Help on message <xxx> button at the bottom of the message page for direct access to the corresponding Help File. See Table 86 Specimen message help file, on page 4-34.

In addition to standard utilities, the Web Event Message display allows users to acknowledge messages.

Important:

A maximum of 100 messages are accessible from the Status Pane. Users are advised to regularly acknowledge processed messages to allow the arrival of new messages.

Acknowledged messages are stored in the PAMHistory file and can be viewed when required.

See Viewing, Archiving, and Deleting History Files, on page 4-36.

To acknowledge Web event messages:

1. Select the required checkbox(es) in the Ack column or click Select all events to automatically select all checkboxes in the Ack column.

2. Click Acknowledge selected events.

Acknowledged messages are removed from the pending event list and are no longer accessible via the Status pane. The Pending Event Message Indicator in the Status pane is updated automatically.

4-34 User's Guide

Sorting and Locating Messages

From the message display, when you hover the mouse in the Type column, an InfoTip gives a brief summary of the message allowing you to rapidly scan the list for the required message(s). Use the standard + and - signs to expand and collapse selected messages.

It may be difficult to locate a message if the list is long, the following short-cuts can be used to organize the display and to locate required messages.

Sorting Messages

Messages can be sorted by clicking a column header to sort the column, e.g. by Severity

(SV), ID, Time, Target, String. Once sorted, messages will be displayed according to the selected column header.

Locating messages

The Search engine can be used to filter the number of displayed logs according to Source,

Target, String, Data attributes. All four attributes are selected by default, but a single attribute can be selected from the dropdown menu.

To search the message list:

1. If known, enter an alphanumeric message string in the String field.

2. Select the required attribute field from the contained in attribute dropdown menu.

3. Case sensitive is selected by default, deselect if required.

4. Click Search to display search results.

5. If you want to carry out another search, click Reset to delete the search history.

Viewing E-mailed Event Messages

These messages contain the same information as those available to connected users, but do

not contain the corresponding help file. See Figure 85. Display Events page, on page 4-33.

Viewing Hardware / Domain Fault Lists

The Fault List page allows you to view messages corresponding to the faults recently encountered by a given hardware element.

To view a Hardware Fault List:

1. Toggle the PAM Tree to display hardware functional status.

2. Click the faulty element node to open the Hardware Status page.

3. Click Display Fault List to open the Fault List page.

4. Click the + sign to expand the required message.

5. Click the Help on message <xxx> button at the bottom of the message page for direct access to the corresponding Help File.

To view a Domain Fault List, see Viewing a Domain Fault List , on page 3-28.

Monitoring the Server 4-35

Viewing, Archiving and Deleting History Files

History and archive files are systematically stored in the PAMSiteData directory:

<WinDrive>:\Program Files\BULL\PAM\PAMSiteData\<DataCompatibilityRelease>

The PAM History Manager allows you to view, archive and delete history files online and provides you with the tools required to download and view history and archive files offline.

As Customer Administrator / Operator, you will frequently consult PAMHistory files for information about system operation.

Note:

System histories and/or archives are only accessible to members of the Customer

Administrator group, whereas User histories and/or archives are accessible to members of both the Customer Administrator and Customer Operator groups. For further details about

histories and archives, see Creating a User History, on page 5-157 and Editing History

Parameters, on page 5-158.

Viewing History Files Online

Note:

Empty history files cannot be viewed.

To view a history file online:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Histories tab.

Figure 87. History Manager Control pane - Histories tab

3. Highlight the required type of history and click View. All the messages contained in the selected history are displayed.

4. Select the message you want to view in detail. The resulting display is the same as for

event messages., on page 4-33

4-36 User's Guide

Viewing History Properties

To view history properties:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Histories tab.

3. Highlight the required type of history and click Properties. The History Properties dialog opens.

Name

Description

Directory

Type

Value

Duration

History name.

Optional description of history contents.

Pathname of the directory used to store histories. If this field is blank, the default Histories directory is used.

Automatic Archiving Policy

Number of days:

The system will automatically create an archive for this history after the number of days specified in the Value field.

Size in KBytes:

The system will automatically create an archive when this history reaches the size in KBytes specified in the Value field.

Number of Records:

The system will automatically create an archive when this history reaches the number of records specified in the Value field.

Number of days / KBytes / records - according to archiving type.

Archive Properties

Regular interval at which the archive is automatically deleted.

Figure 88. History properties

Note:

As Customer Administrator, you can modify History properties from the Histories Control

pane. See Editing History Parameters, on page 5-158.

Monitoring the Server 4-37

Manually Archiving History Files

In general, history files are automatically archived at regular periods. However, you can choose to manually archive a history file at any time, if required.

Note:

Empty history files cannot be archived.

To manually archive a history file:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Histories tab.

3. Select the required type of history checkbox or select the Archive All checkbox to archive all histories.

4. Click Archive checked histories. A dialog box opens, requesting you to confirm file archiving.

5. Click OK to confirm. The selected history(ies) are archived.

Viewing Archive Files Online

Note:

Empty archive files cannot be viewed.

To view an archive file online:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Archived histories tab.

Figure 89. History Manager Control pane - Archived histories tab

3. Use the scroll-down menu to select the type of history archive you want to display. The corresponding list of archived histories appears in the Archiving date zone.

4. Highlight the required archiving date and click View. All the messages contained in the selected archive are displayed.

5. Select the message you want to view in detail. The resulting display is the same as for

event messages., on page 4-33

4-38 User's Guide

Viewing Archive Properties

To view archive properties:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Archived histories tab.

3. Use the scroll-down menu to select the type of history archive you want to display. The corresponding list of archived histories appears in the Archiving date zone.

4. Highlight the required archiving date and click Properties. The Archive Properties dialog opens.

Name

Description

Directory

Date

Duration

Number of messages

File Size (Kb)

Creation Mode

History name, archiving date and time.

Optional description of history contents.

Pathname of the directory used to store histories. If this field is blank, the default Histories directory is used.

Archiving date and time.

Regular interval at which the archive is automatically deleted.

Number of messages in the archive.

Archive size in Kb.

Mode used to create the archive:

• Automatic archiving

• Manual archiving

• History error

Figure 90. Archive properties

Note:

As Customer Administrator, you can modify Archive properties from the Histories Control

pane. See Editing History Parameters, on page 5-158.

Monitoring the Server 4-39

Manually Deleting a History Archive File

In general, history archive files are automatically deleted at regular periods. However, you can choose to manually delete a history archive file at any time, if required.

To manually delete a history archive file:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Archived histories tab.

3. Use the scroll-down menu to select the type of history archive you want to delete. The corresponding list of archived histories appears in the Archiving date zone.

4. Select the required archive checkbox or select the Delete All checkbox to delete all archives.

5. Click OK to confirm. The selected archives are deleted.

Downloading History / Archive Files for Offline Viewing

The PAM History Manager allows you to compress and download history and/or archive files to a local or network directory for offline viewing. The downloaded files can then be viewed with the History Viewer tool which displays all the sort options available online, but does not contain the corresponding help file.

Note:

Empty history / archive files cannot be downloaded.

Downloading History Viewer

Before downloading history and/or archive files for offline viewing, you are advised to download the History Viewer tool:

1. From the PAM Tree pane, click Downloads -> History Viewer to download the

HistoryViewer.zip file.

2. Unzip all the files in the HistoryViewer.zip file to a directory of your choice.

3. Select the HistoryViewer.htm file and create a shortcut on your desktop. The History

Viewer tool is now ready for use.

Downloading History / Archive Files

To download history / archive files:

1. From the PAM Tree pane, click History Manager to open the Control pane.

2. Select the Histories or Archived histories tab, as required.

3. Select the required type of history or archive:

Histories

- Select the required history checkbox or select the Basket All checkbox to download all histories.

Archives

- Use the scroll-down menu to select the required archive. The corresponding list of archived histories appears in the Archiving date zone.

- Select the required archive checkbox or select the Basket All checkbox to download all archives.

4. Click Add selected files to basket.

Note:

Files already selected for downloading can be viewed by clicking Show basket details.

4-40 User's Guide

5. Click Download Compressed File to compress and download the histories/archives to the required local or network directory for offline viewing.

Viewing History / Archive Files Offline

1. Unzip all the files in the History.zip file to a directory of your choice.

2. Click the HistoryViewer.htm file to open the View History File page.

3. Complete the History File Name field and click Read, or click Browse to search for and load the required history or archive file.

4. Select the message you want to view in detail. The resulting display is the same as for

event messages., on page 4-33

Note:

For further details about histories and archives, see Creating a User History, on page 5-157

and Editing History Parameters, on page 5-158.

Monitoring the Server 4-41

What to Do if an Incident Occurs

Server activity is systematically logged in the System History files, which you can view as

Customer Administrator at any time.

When an incident occurs, PAM software informs users via:

• the Status pane,

• Event Message / History file,

• e-mail / SNMP traps (users with an appropriate Event Message subscription),

• an Autocall to the Bull Service Center (according to your maintenance contract).

In most cases, PAM software handles the incident and ensures operational continuity while the Bull Service Center analyzes the incident and implements the necessary corrective or preventive maintenance measures.

Whenever you are informed of an incident:

• functional or presence status indicators / icon NOT green,

• event message or history file marked with the WARNING or ERROR symbol, you are advised to connect to the PAM Web site (if you are not already connected) and to investigate the incident.

Investigating Incidents

1. Check the system functional status icon in the Status pane. If the icon is not green, the server is not operating correctly. See Table 27. System Functional Status / Expected

Domain State, on page 4-43.

2. Open the Domain Manager Control pane and identify the domain using the faulty hardware element by hovering the mouse over the Domain Memo icons to display the

Cell infotip.

See Table28 NovaScale SMP Server Domain Cell Resources, on page 4-44 and Table 29

NovaScale Partitioned Server Domain Cell Resources, on page 4-45.

- If the domain is operating normally, RUNNING is displayed in the Domain State field.

- If the domain has been automatically powered down, INACTIVE is displayed in the

Domain State field.

See Table 27. System Functional Status / Expected Domain State, on page 4-43 and

Chapter 3. Managing Domains, on page 3-1.

Warning:

If system functional status is critical (flashing red icon), immediately save data, close open applications and shut down the domain Operating System.

3. Toggle the PAM Tree to view hardware functional status (round, colored indicator next to the Hardware Monitor node). The PAM Tree will automatically expand down to the faulty hardware element.

4. Check domain state by clicking Domain Manager in the PAM tree.

4-42 User's Guide

System Functional Status / Expected Domain State

Icon System Functional Status

Green

NORMAL

Expected Domain State

RUNNING

WARNING RUNNING

Yellow

INACTIVE (auto Power OFF) / RUNNING

An automatic Power OFF request may be sent by PAM software to the domain Operating

System:

- If the domain Operating System is configured to accept PAM Power OFF requests, it automatically saves data, closes open applications and shuts down.

- If the Operating System is not configured to

Orange

Flashing

Red

Flashing advised to manually save data, close open applications and shut down the Operating

System.

Note:

When system functional status is FATAL, the icon does not always remain red. Therefore, an orange functional status icon may indicate a FATAL hardware status.

INACTIVE

An automatic Force Power OFF command may be performed by PAM software on the domain

Operating System.

Note:

The Operating System does not have time to save data and close applications before it is shut down.

NOT ACCESSIBLE

Purple

Table 27.

CSS functional status / domain state

INACTIVE

5. Click the faulty hardware element to open the corresponding Hardware Status page.

6. Check Power and Temperature tabs. If a power and/or temperature indicator is NOT green, a power- and/or temperature-specific fault has occurred. See Power Status

Indicators and Temperature Status Indicators, on page 4-18.

7. Click Display Faults List for direct access to server logs. If the Display Faults List button is not accessible, click History Manager → System → PAM History for the corresponding

log. See Viewing Detailed Hardware Status, on page 4-15.

8. Expand the log for direct access to the corresponding Help File (at the bottom of the page). The Help File explains the message and how to deal with the incident.

Important:

To maintain a trace of transient faults, PAM Tree functional and/or presence status indicators will not change color until the domain has been powered OFF/ON, even although the error has been corrected.

Monitoring the Server 4-43

The following tables list server domain cell resources.

NovaScale SMP Server Domain Cell Resources

Cell 0

Cell 1

Cell 0

Cell 1

Cell 2

Cell 3

Cell 0

Cell 1

Cell 2

Cell 3

Cell 4

Cell 5

Cell 0

Cell 1

Cell 2

Cell 3

Cell 4

Cell 5

Cell 6

Cell 7

NovaScale 5085 SMP Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_QBB1

NovaScale 5165 SMP Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_QBB1

Module1_QBB0

Module1_QBB1

NovaScale 5245 SMP Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_QBB1

Module1_QBB0

Module1_QBB1

Module2_QBB0

Module2_QBB1

NovaScale 5325 SMP Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_QBB1

Module1_QBB0

Module1_QBB1

Module2_QBB0

Module2_QBB1

Module3_QBB0

Module3_QBB1

Table 28.

NovaScale SMP server domain cell resources

4-44 User's Guide

NovaScale Partitioned Server Domain Cell Resources

Cell 0

Cell 1

Cell 2

Cell 3

Cell 4

Cell 5

Cell 6

Cell 7

Cell 0

Cell 1

Cell 0

Cell 1

Cell 2

Cell 3

Cell 0

Cell 1

Cell 2

Cell 3

Cell 4

Cell 5

NovaScale 5085 Partitioned Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_IOC1, Module0_QBB1, Module0_DIB1

NovaScale 5165 Partitioned Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_IOC1, Module0_QBB1, Module0_DIB1

Module1_IOC0, Module1_QBB0, Module0_DIB0

Module1_IOC1, Module1_QBB1, Module0_DIB1

NovaScale 5245 Partitioned Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_IOC1, Module0_QBB1, Module0_DIB1

Module1_IOC0, Module1_QBB0, Module0_DIB0

Module1_IOC1, Module1_QBB1, Module0_DIB1

Module2_IOC0, Module2_QBB0, Module0_DIB0

Module2_IOC1, Module2_QBB1, Module0_DIB1

NovaScale 5325 Partitioned Server

Module0_IOC0, Module0_QBB0, Module0_DIB0

Module0_IOC1, Module0_QBB1, Module0_DIB1

Module1_IOC0, Module1_QBB0, Module0_DIB0

Module1_IOC1, Module1_QBB1, Module0_DIB1

Module2_IOC0, Module2_QBB0, Module0_DIB0

Module2_IOC1, Module2_QBB1, Module0_DIB1

Module3_IOC0, Module3_QBB0, Module0_DIB0

Module3_IOC1, Module3_QBB1, Module0_DIB1

Table 29.

NovaScale partitioned server domain cell resources

Monitoring the Server 4-45

Dealing with Incidents

When you open the incident Help File, you may be requested to perform straightforward checks and actions or to contact your Customer Service Engineer.

This section explains how to respond to the following requests:

• Check Environmental Conditions

• Check Hardware Availability

• Check Hardware Connections

• Exclude a Hardware Element

• Check Hardware Exclusion Status

• Check Hardware Fault Status

• Check Power Status

• Check Temperature Status

• Check Histories and Events

• Check SNMP Settings

• Check Autocall Settings

• Check PAM Version

• Check MAESTRO Version

• Check Writing Rules

• Power ON/OFF the Domain

• Reboot the PAP Application

• Modify LUN Properties

• Check, Test, and Reset the PMB

• Create an Action Request Package

Checking Environmental Conditions

If you are requested to check environmental conditions, ensure that the computer room is compliant with the specifications set out in Appendix A.Specifications.

Checking Hardware Availability

If you are requested to check hardware availability:

1. Check that the CSS module availability status bar is green. If the status bar is not green, the CSS module has not been detected by PAM software. Check the physical PMB to PAP unit Ethernet link connection.

2. Toggle the PAM Tree to view hardware presence status (square, colored indicator next to the Hardware Monitor node).

3. Expand the Hardware Monitor node to view the presence status of all hardware elements.

If a hardware presence status indicator is NOT green, the hardware element is either missing or not accessible.

Important:

If a PAM Tree hardware presence status indicator is not green, this could be normal if the corresponding hardware element has been removed for maintenance.

4-46 User's Guide

Checking Hardware Connections

If you are requested to check hardware connections, manually and visually ensure that all cables are correctly inserted in their corresponding hardware ports. See Cabling

Guide, 86 A1 34ER.

Excluding a Hardware Element and Checking Exclusion Status

As Customer Administrator, you can logically Exclude a redundant hardware element from the domain until it has been repaired or replaced. Exclusion is taken into account at the next

domain power ON. See Excluding / Including Hardware Elements, on page 4-23.

If you are requested to check hardware exclusion status, use the Hardware Search engine to search for and view Excluded hardware elements. See Using the Hardware Search Engine,

on page 4-10.

You can also view domain hardware exclusion status from the Domain Hardware Details

page. See Viewing Domain Configuration, Resources and Status, on page 3-35.

Checking Hardware Fault Status

If you are requested to check hardware fault status:

1. Click the corresponding hardware element in the PAM Tree to open the Hardware Status page.

2. Check the General tab. If the fault status indicator is NOT green, a fault has occurred.

See Fault Status Indicators, on page 4-16.

Checking Hardware Power Status

If you are requested to check hardware power status:

1. Click the corresponding hardware element in the PAM Tree to open the Hardware Status page.

2. Check the Power tab. If a power indicator is NOT green, a power-specific fault has occurred.

See Power Status Indicators, on page 4-18.

Checking Hardware Temperature Status

If you are requested to check temperature status:

1. Click the corresponding hardware element in the PAM Tree to open the Hardware Status page.

2. Check the Temperature tab. If a temperature indicator is NOT green, a temperature-specific fault has occurred.

See Temperature Status Indicators, on page 4-20.

Checking Histories and Events

If you are requested to check histories / events, refer to Viewing and Managing PAM Event

Messages and History Files, on page 4-31.

Monitoring the Server 4-47

Checking SNMP Settings

If you are requested to check SNMP settings, IP address, or server name for an event subscription:

1. From the PAM Tree, click Configuration Tasks → Events → Channels and check that the

SNMP Channel is enabled.

2. Click Subscriptions to view configured subscriptions. Channel type is indicated in the

Channel column.

3. Select the required SNMP Channel subscription from the list and click Edit to view / modify SNMP settings.

Checking Autocall Settings

If you are requested to check Autocall settings:

1. From the PAM Tree, click Configuration Tasks -> Autocalls and check that the Enable

Autocalls checkbox is selected.

2. Check dispatch modes and corresponding settings.

Checking PAM Version

If you are requested to check PAM version:

From the PAM Tree, click PAP to display the PAP Unit Information page. PAM version is displayed at the top of the page.

Checking MAESTRO Version

If you are requested to check MAESTRO version:

From the PAM Tree, click Hardware Monitor → PMB to open the PMB Status page. Click the

FIRMWARE tab to view MAESTRO version.

Checking Writing Rules

If you are requested to check writing rules, see PAM Writing Rules.

Powering OFF/ON a Domain

If you are requested to Power OFF/ON or Force Power OFF a domain, ensure that you have saved data and closed open applications.

See Managing Domains, on page 3-1.

Rebooting the PAP Application

If you are requested to reboot the PAP application:

1. From the Microsoft Windows home page, click Start → Programs → Administrative Tools

→ Component Services.

2. From Component Services, click Console Root → Component Services → Computers → My

Computer → COM+ Applications → PAP.

3. Right click PAP to open the shortcut menu. Click Shutdown.

4. Activate the required PAM version to reboot the PAP application.

See Deploying a New PAM Release, on page 5-23 and

Activating a PAM Version, on page 5-24.

4-48 User's Guide

Modifying LUN Properties

If you are requested to modify LUN properties:

Refer to Configuring Disks, on page 5-5 and to the appropriate Disk Subsystem

documentation.

Checking, Testing and Resetting the PMB

The PMB is located in the module at the base of the cabinet and links the server to the PAP unit via an Ethernet link. You may be required to carry out the following checks / actions:

• Check that PMB LED #0 is blinking green (PMB booted correctly):

When the system is powered on, the 7 activity and status LEDs (LED #1-LED #7) are

switched off and LED #0 is blinking. See PMB Leds and Code Wheels, on page 4-50.

Check PMB code wheel settings. See PMB Leds and Code Wheels, on page 4-50.

• Check that the Ethernet cable linking the server to the PAP unit is correctly inserted and that the Ethernet link LED is green.

• Check the PAP - PMB link by pinging the PAP and the PMB:

PAP Address PMB 0 Address PMB 1 Address PMB 2 Address PMB 3 Address

10.10.240.240

10.10.0.1

10.10.0.2

10.10.0.3

10.10.0.4

• Reset the PMB by pressing the RESET button. PMB firmware will be rebooted. See PMB

Leds and Code Wheels, on page 4-50.

Monitoring the Server 4-49

PMB LEDs and Code Wheels

Up to 16 Central Subsystems can be linked, via Platform Management Boards (PMBs) to a single PAP unit, to provide a single point of administration and maintenance.

Each PMB is equipped with two code wheels used to identify each Central Subsystem and each CSS module in your configuration. These code wheels are set prior to shipping (factory default setting), according to configuration.

Code wheels

Cabinet

Module

Load push-button

Reset PMB

Reserved

Serial port (DB9)

(reserved)

Ethernet connector

PAP link

System activity and status LEDs

LED7

LED4

LED3

LED0

LED4 to LED7: orange

LED0 to LED3: green

PMB status LED

Orange LED

OFF = OK

ON = PMB hot-plugged

Green LED: Ethernet link status (ON = OK)

Yellow LED: Link activity (ON = transmit)

For guidance, PMB code wheel settings are indicated in the following table:

8th

9th

10th

11th

12th

13th

14th

15th

16th

1st

2nd

3rd

4th

5th

6th

7th

CSS

PMB Code Wheel

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

CSS HW Identifier

Figure 91. PMB LED location

PAM

07

08

09

10

11

12

13

14

15

00

01

02

03

04

05

06

CSS Module

PMB Code Wheel

CSS Module 0 CSS Module 1

0

0

1

1

0

0

0

0

0

1

1

1

1

1

0

0

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

1

4-50 User's Guide

Creating an Action Request Package

PAM software allows you to collect all the files required to troubleshoot a Bull NovaScale

Server via the Action Request Package tool. Once collected, files are compressed to ZIP format for easy transfer to the BULL Remote Maintenance Center.

Note:

Before PAM Release 8, use the BackUpRestore utility to copy and restore the files stored in the PAM SiteData directory.

Creating a Default Action Request Package

1. From the PAM Tree pane, click Downloads to open the Control pane.

Figure 92. Action Request Package control pane

2. Select the AR Package tab and enter the Action Request reference given by the Customer

Support Center.

3. Click Build Action Request package to collect, compress and download ALL the files contained in the various directories.

4. Transfer the ZIP to the BULL Remote Maintenance Center for analysis.

Monitoring the Server 4-51

4-52 User's Guide

Creating a Filtered Action Request Package

Important:

To ensure the consistency of Action Request Package contents, you are advised to only use filtering options if specifically required.

1. From the PAM Tree pane, click Downloads to open the Control pane.

2. Select the AR Package tab and enter the Action Request reference given by the Customer

Support Center.

3. Click Show Details to display filtering options.

Filterable File Types Action

Current Files

Dates

Windows Event Log: Application

Windows Event Log: Security

Windows Event Log: System

Current History Files

These files are selected by default.

If you do not want to include these files, deselect the corresponding checkboxes.

All current Windows Event

Log files.

All history files in the PAM

Site Directory.

Archived History Files

Logs

Error Reports

Archived Files

These files are selected by default.

If you do not want to include these files, deselect the corresponding checkboxes.

Default dates:

Today + 3 preceding days.

Enter new From / To dates to include archives outside the default dates.

Figure 93. Action Request Package details

4. Clear filterable checkboxes as required and/or change archive collection dates.

Monitoring the Server 4-53

5. Click Build Action Request package to collect, compress and download files.

6. Transfer the ZIP file to the BULL Remote Maintenance Center for analysis.

Creating a Custom Package

PAM software allows you to collect one or more selected files from the PAM Site Data

Directory via the Custom Package tool. Once collected, files are compressed to ZIP format.

This option allows you to precisely select the files you want to collect and download for analysis.

To create a Custom Package:

1. From the PAM Tree pane, click Downloads to open the Control pane.

Figure 94. Custom Package control pane

2. Select the Custom Package tab and enter the Custom Package reference.

3. Click Add to select the PAM Site Data files to be included in the package.

4-54 User's Guide

Figure 95. Custom Package Add files pane

4. Click Build Custom Package to collect, compress and download the selected files.

5. Save the resulting ZIP file as required.

Monitoring the Server 4-55

4-56 User's Guide

Chapter 5. Tips and Features for Administrators

This chapter explains how, as Customer Administrator, you can configure the server to suit your working environment. It includes the following sections:

• Section I -

Setting up Server Users and Configuring Disks, on page 5-3

• Section II -

Using EFI Utilities, on page 5-6

• Section III -

Customizing PAM Software, on page 5-16

• Section IV -

Configuring Domains, see page 5-28

• Section V -

Creating Event Subscriptions and User Histories, on page 5-132

Notes:

Customer Administrators and Customer Operators are respectively advised to consult the

Administrator's Memorandum, on page xxv or the Operator's Memorandum, on page xxvii

for a detailed summary of the everyday tasks they will perform.

Before proceeding to configure the server, please refer to PAM Writing Rules, on page xxii.

For further information about user accounts and passwords, see Setting up PAP Unit Users.

Important:

Certain domain configuration and management tools are reserved for use with partitioned servers, extended systems and/or a Storage Area Network(SAN).

Please contact your Bull Sales Representative for sales information.

Tips and Features for Administrators 5-1

5-2 User's Guide

Section I - Setting up Users and Configuring Data Disks

This section explains how to:

Set up Server Users, on page 5-4

Configure System and Data Disks, on page 5-5

Tips and Features for Administrators 5-3

Setting up Server Users

As Customer Administrator, you must set up user accounts and passwords to control access to the server.

The operating system pre-installed on the server provides standard security features for controlling access to applications and resources.

For further details, refer to the Microsoft Windows / Linux documentation, as applicable.

Note:

You are advised to maintain a detailed record of authorized users.

Microsoft Windows

Default user access control is not pre-configured on systems running under Microsoft

Windows.

You are advised to set up the Administrator account before proceeding to set up users and groups via the standard Microsoft Windows administration tools.

Linux

Two default users are pre-configured on systems running under Linux:

User Name

Administrator root

User linux

Password root root

You are advised to change the default Administrator name and password before proceeding to set up users and groups via the standard Linux administration tools.

5-4 User's Guide

Configuring System and Data Disks

Optionally, for optimum storage, security and performance, the server may be delivered with pre-configured disk racks.

New system and/or data disks can be created via the utility delivered with the storage sub-system.

Note:

For further details about configuring system and data disks, refer to the appropriate Disk

Subsystem documentation.

Creating New FC Logical System or Data Disks

Optionally, the server may be delivered with one or two disk rack(s) each containing two

RAID #1 system disks per domain and one pool spare disk, and offering ten free slots for data disks. Slots are numbered from 0 to14 (from left to right).

For optimum storage, performance, and reliability, you are advised to use RAID level 1 for system disk configuration and RAID level 5 for data disk configuration.

To create a new logical system or data disk:

1. From the Microsoft Windows desktop on the PAP unit, launch iSM Client.

2. Follow the instructions on the screen.

Tips and Features for Administrators 5-5

Section II - Using EFI Utilities

This section explains how to:

Use the EFI Boot Manager, on page 5-7

Use the EFI Shell, on page 5-9

Use the EFI to Set up and Configure a Network, on page 5-14

Use the EFI to Load FTP Server / Client, on page 5-15

5-6 User's Guide

Using the EFI Boot Manager

The EFI (Extensible Firmware Interface) Boot Manager allows you to control the server's booting environment. From the Boot Manager, you can choose to invoke the Extensible

Firmware Interface (EFI) Shell or to go to the Boot Option Maintenance Menu.

To enter the EFI Boot Manager:

1. From the PAM Tree, click Domain Manager → Power ON to power up the required domain.

2. From the keyboard, press the Control key twice to display the KVM Switch Command

Menu.

3. Select the required system channel port with the ↑↓ keys, according to configuration. See

KVM port configuration, in the User's Guide.

4. Press Enter to activate the required system channel and exit the Command Mode.

Note:

The system automatically boots on the first option in the list without user intervention after a timeout. To modify the timeout, use Set Auto Boot Timeout in the Boot Option

Maintenance Menu.

5. From the Boot Manager Menu, select the EFI Shell option with the ↑↓ keys and press

Enter.

EFI Boot Manager Options

EFI Shell

A simple, interactive environment that allows EFI device drivers to be loaded, EFI applications to be launched, and operating systems to be booted. The EFI shell also provides a set of basic commands used to manage files and the system environment variables. For more

information on the EFI Shell, refer to Using the EFI Shell on page 5-9.

Boot Options

Files that you include as boot options. You add and delete boot options by using the Boot

Maintenance Menu. Each boot option specifies an EFI executable with possible options. For information on the Boot Maintenance Menu options, refer to Table 30.

Boot Option Maintenance Menu

The EFI Boot Maintenance Manager allows the user to add boot options, delete boot options, launch an EFI application, and set the auto boot time out value.

If there are no boot options in the system (and no integrated shell), the Boot Maintenance

Menu is presented. If boot options are available, then the set of available boot options is displayed, and the user can select one or choose to go to the Boot Maintenance Menu.

If the time out period is not zero, then the system will auto boot the first boot selection after the time out has expired. If the time out period is zero, then the EFI Boot Manager will wait for the user to select an option. Table 30 describes each menu item in the Boot Maintenance

Menu.

Note:

You can use the → ← ↑↓ keys to scroll through the Boot Maintenance Menu.

Tips and Features for Administrators 5-7

Boot Option Description

Boot from a File This option searches all the EFI System Partitions in the system.

For each partition it looks for an EFI directory. If the EFI directory is found, it looks in each of the subdirectories below EFI.

In each of those subdirectories, it looks for the first file that is an executable EFI Application.

Each of the EFI Applications that meet this criteria are automatically added as a possible boot option. In addition, legacy boot options for A: and

C: are also added if those devices are present.

This option allows the user to launch an application without adding it as a boot option.

The EFI Boot Manager will search the root directories and the

\EFI\TOOLS directories of all of the EFI System Partitions present in the system for the specified EFI Application.

Add a Boot Option Allows the user to specify the name of the EFI Application to add as a boot option.

The EFI Boot Manager searches the same partitions and directories as described in Boot from a File, until it finds an EFI Application with the specified name.

This menu also allows the user to provide either ASCII or UNICODE arguments to the option that will be launched.

Delete Boot

Options

Allows you to delete a specific boot option or all boot options. Highlight the option you want to delete and enter <d>. Enter <y> to confirm.

Change Boot Order Allows you to control the relative order in which the EFI Boot Manager attempts boot options. To change the boot order, highlight the boot option and enter <u> to move the item up one order, <d> to move the item down one order. For help on the control key sequences you need for this option, refer to the help menu.

Manage Boot Next

Setting

Allows you to select a boot option to use one time (the next boot operation).

Set Auto Boot

Timeout

Allows you to define the value in seconds that pass before the system automatically boots without user intervention. Setting this value to zero disables the timeout feature.

Cold Reset

Exit

Performs a platform-specific cold reset of the system. A cold reset traditionally means a full platform reset.

Returns control to the EFI Boot Manager main menu. Selecting this option will display the active boot devices, including a possible integrated shell

(if the implementation is so constructed).

Table 30.

Boot Option Maintenance Menu

5-8 User's Guide

Using the EFI Shell

The EFI (Extensible Firmware Interface) Shell is a simple, interactive user interface that allows

EFI device drivers to be loaded, EFI applications to be launched, and operating systems to be booted. In addition, the Shell provides a set of basic commands used to manage files and the system environment variables.

The EFI Shell supports command line interface and batch scripting.

Entering the EFI Shell

To enter the EFI Shell:

1. From the PAM Tree, click Domain Manager → Power ON to power up the required domain.

2. From the keyboard, press the Control key twice to display the KVM Switch Command

Menu.

3. To display the KVM Switch Command Menu from the keyboard: a. If you have a KVM switch "Avocent SwitchView 1000" installed, press the "Scroll

Lock" key twice then the Space key.

b. If you have another KVM switch installed, press the Control key twice.

4. Select the required system channel port with the ↑↓ keys, according to configuration. See

KVM port configuration, in the User's Guide.

5. Press Enter to activate the required system channel and exit the Command Mode. After a few seconds, the Boot Manager menu is displayed.

6. From the Boot Manager Menu, select the EFI Shell option with the ↑↓ keys and press

Enter.

When the EFI Shell is invoked, it first looks for commands in the file startup.nsh on the execution path defined by the environment. There is no requirement for a startup file to exist.

Once the startup file commands are completed, the Shell looks for commands from console input device.

Note:

The system automatically boots on the first option in the list without user intervention after a timeout. To modify timeout, use Set Auto Boot Timeout in the Boot Option Maintenance Menu.

Note:

It is possible to reset the KVM switch "Avocent SwitchView 1000", while pressing the "Scroll

Lock" key twice then the End key.

EFI Shell Command Syntax

The EFI Shell implements a programming language that provides control over the execution of individual commands. When the Shell scans its input, it always treats certain characters specially: (

#

,

>

,

%

,

*

,

?

,

[

,

^

, space

, and

newline).

When a command contains a defined alias, the Shell replaces the alias with its definition

(see alias

command in this chapter). If the argument is prefixed with the

^

character, however, the argument is treated as a literal argument and alias processing is not performed.

Note:

In interactive execution, the Shell performs variable substitution, then expands wildcards before the command is executed.

In batch script execution, the Shell performs argument substitution, then variable substitution, then expands wildcards before the command is executed.

Tips and Features for Administrators 5-9

Variable Substitution

Environment variables can be set and viewed through the use of the set

command (see set command in this chapter). To access the value of an environment variable as an argument to a Shell command, delimit the name of the variable with the

%

character before and after the variable name; for example,

%myvariable%

.

The Shell maintains a special variable, named lasterror

. The variable contains the return code of the most recently executed Shell command.

Wildcard Expansion

The

*, ?

and

[

characters can be used as wildcard characters in filename arguments to

Shell commands.

If an argument contains one or more of these characters, the Shell processes the argument for

file meta-arguments and expands the argument list to include all filenames matching the pattern.

These characters are part of patterns which represent file and directory names.

Character Sequence Meaning

" * "

" ?

"

"

[chars]

"

Matches zero or more characters in a file name

Matches exactly one character of a file name

Defines a set of characters; the pattern matches any single character in the set. Characters in the set are not separated. Ranges of characters can be specified by specifying the first character in a range, then the – character, then the last character in the range. Example: [a-zA-Z]

Table 31.

Wildcard character expansion

Output Redirection

Output of EFI Shell commands can be redirected to files, according to the following syntax:

Command Output Redirection

> unicode_output_file_pathname

>a ascii_output_file_pathname

1> unicode_output_file_pathname

1>a ascii_output_file_pathname

2> unicode_output_file_pathname

2>a ascii_output_file_pathname

>> unicode_output_file_pathname

>>a ascii_output_file_pathname standard output to a unicode file standard output to an ascii file standard output to a unicode file standard output to an ascii file standard error to a unicode file standard error to an ascii file standard output appended to a unicode file standard output appended to an ascii file

1>> unicode_output_file_pathname standard output appended to a unicode file

1>>a ascii_output_file_pathname standard output appended to an ascii file

Table 32.

Output redirection syntax

The Shell will redirect standard output to a single file and standard error to a single file.

Redirecting both standard output and standard error to the same file is allowed. Redirecting

Standard output to more than one file on the same command is not supported. Similarly, redirecting to multiple files is not supported for standard error.

5-10 User's Guide

Quoting

Quotation marks in the EFI Shell are used for argument grouping. A quoted string is treated as a single argument to a command, and any whitespace characters included in the quoted string are just part of that single argument.

Quoting an environment variable does not have any effect on the de-referencing of that variable. Double quotation marks

“”

are used to denote strings. Single quotation marks are not treated specially by the Shell in any way. Empty strings are treated as valid command line arguments.

Executing Batch Scripts

The EFI Shell has the capability of executing commands from a file (batch script). EFI Shell batch script files are named using the .nsh extension. Batch script files can be either

UNICODE or ASCII format files. EFI Shell script files are invoked by entering the filename at the command prompt, with or without the filename extension.

Up to nine (9) positional arguments are supported for batch scripts. Positional argument substitution is performed before the execution of each line in the script file. Positional arguments are denoted by

%n

, where n is a digit between 0 and 9. By convention,

%0

is the name of the script file currently being executed. In batch scripts, argument substitution is performed first, then variable substitution. Thus, for a variable containing

%2

, the variable will be replaced with the literal string

%2

, not the second argument on the command line. If no real argument is found to substitute for a positional argument, then the positional argument is ignored. Script file execution can be nested; that is, script files may be executed from within other script files. Recursion is allowed.

Output redirection is fully supported. Output redirection on a command in a script file causes the output for that command to be redirected. Output redirection on the invocation of a batch script causes the output for all commands executed from that batch script to be redirected to the file, with the output of each command appended to the end of the file.

By default, both the input and output for all commands executed from a batch script are echoed to the console. Display of commands read from a batch file can be suppressed via the echo –off

command (see echo

). If output for a command is redirected to a file, then that output is not displayed on the console. Note that commands executed from a batch script are not saved by the Shell for DOSkey history (up-arrow command recall).

Error Handling in Batch Scripts

By default, if an error is encountered during the execution of a command in a batch script, the script will continue to execute.

The lasterror

Shell variable allows batch scripts to test the results of the most recently executed command using the if

command. This variable is not an environment variable, but is a special variable maintained by the Shell for the lifetime of that instance of the Shell.

Comments in Script Files

Comments can be embedded in batch scripts. The # character on a line is used to denote that all characters on the same line and to the right of the # are to be ignored by the Shell.

Comments are not echoed to the console.

EFI Shell Commands

Most Shell commands can be invoked from the EFI Shell prompt. However there are several commands that are only available for use from within batch script files.

Note:

The "Batch-only" column indicates if the command is only available from within script files.

The following sections provide more details on each of the individual commands.

Command help command_name displays the details of the command_name .

Tips and Features for Administrators 5-11

load loadbmp ls map memmap mkdir mm mode cd cls comp

No

No

No connect cp date dblk devices devtree dh

No

No disconnect No dmem No

No

No

No

No

No dmpstore drivers drvcfg drvdiag echo edit err exit for/endfor

No

No

No

No

No

No

No

No

Yes goto Yes guid help hexedit if/endif

No

No

No

Yes

Command Batch alias attrib bcfg only

No

No

No

Description

Displays, creates, or deletes aliases in the EFI Shell

Displays or changes the attributes of files or directories

Displays/modifies the driver/boot configuration break No Executes a break point

Displays or changes the current directory

Clears the standard output with an optional background color

Compares the contents of two files

Binds an EFI driver to a device and starts the driver

Copies one or more files/directories to another location

Displays the current date or sets the date in the system

Displays the contents of blocks from a block device

Displays the list of devices being managed by EFI drivers

Displays the tree of devices that follow the EFI Driver Model

Displays the handles in the EFI environment

Disconnects one or more drivers from a device

Displays the contents of memory

Displays all NVRAM variables

Displays the list of drivers that follow the EFI Driver Model

Invokes the Driver Configuration Protocol

Invokes the Driver Diagnostics Protocol

Displays messages or turns command echoing on or off

Edits an ASCII or UNICODE file in full screen.

Displays or changes the error level

Exits the EFI Shell

Executes commands for each item in a set of items

Makes batch file execution jump to another location

Displays all the GUIDs in the EFI environment

Displays commands list or verbose help of a command

Edits with hex mode in full screen

Executes commands in specified conditions

No

No

No

No

No

No

No

No

Loads EFI drivers

Displays a Bitmap file onto the screen

Displays a list of files and subdirectories in a directory

Displays or defines mappings

Displays the memory map

Creates one or more directories

Displays or modifies MEM/IO/PCI

Displays or changes the mode of the console output device

5-12 User's Guide

Command mount

Batch only

No

Description

Mounts a file system on a block device mv openInfo pause pci

No

No

No

No reconnect No reset No rm set stall time

No

No

No

No type unload ver vol

No

No

No

No

Moves one or more files/directories to destination

Displays the protocols on a handle and the agents

Prints a message and suspends for keyboard input

Displays PCI devices or PCI function configuration space

Reconnects one or more drivers from a device

Resets the system

Deletes one or more files or directories

Displays, creates, changes or deletes EFI environment variables

Stalls the processor for some microseconds

Displays the current time or sets the time of the system

Displays the contents of a file

Unloads a protocol image

Displays the version information

Displays volume information of the file system

Table 33.

List of EFI Shell Commands

Tips and Features for Administrators 5-13

EFI Network Setup and Configuration

The EFI (Extensible Firmware Interface) Utilities delivered with the system provide a complete set of TCP/IPv4 network stack and configuration tools. Ethernet adapters utilizing 6 bit UNDI option ROMs are supported.

Important:

To access this feature, please connect the Enterprise network to the embedded Ethernet board on the IOR of the domain master IO board. Intel PRO 1000T and 1000F adapters are not supported.

Note:

These utilities are installed in the EFI partition of the system disk in the EFI\Tools directory.

The list and respective manual pages for each utility can be found on the Bull NovaScale

Server Resource CD-Rom.

Network stack configuration commands must be executed after booting to EFI Shell. To simplify network setup, these commands should be grouped, via an EFI batch script, to form a single one-line command.

Manual EFI Network Configuration

1. Load the TCP/IP protocol via the EFI load command.

Note:

As the load command does not use the search path to locate protocols, specify the path and the .efi extension.

fso:\efi\tools\tcpipv4.efi

2. Configure the network interfaces with the ifconfig command:

The simple form of the command is: ifconfig <interface> inet <ip address> up where <ip address> is the address assigned to the system. If the system is connected to a network that uses subnetting, a subnet mask would also need to be specified as follows: ifconfig sni0 inet <ip address> netmask <netmask> up where <netmask> is the network mask assigned to the network.

Note:

The TCP/IP stack contains a "lo0" loopback interface which can be optionally be configured with the "sni0" Ethernet interface if a compatible UNDI Ethernet adapter is installed. Configuration is performed with the ifconfig command.

3. If multiple network or subnetwork networking is required, set a gateway address for the appropriate gateway(s) attached to the network, via the route command as follows: route add <destination> <gateway ip address> where <destination> specifies the target network or host and <gateway ip address> specifies the network gateway address responsible for routing data to the destination.

If default is used for <destination>, a default route will be set.

5-14 User's Guide

Example Network Configuration Batch File

An example network configuration batch file named NetConf.nsh is installed in the EFI directory of the EFI Service Partition.

This file loads the TCP/IP, configures the Ethernet interface to the IP address given as first argument to this file, configures the optional second argument as the gateway, and loads the

FTP Server (daemon).

echo –off if %1empty == empty then

echo usage netconf {local ip–addr} [router ip addr]

goto End endif load fs0:\efi\tools\tcpipv4.efi

ifconfig sni0 %1 netmask 255.255.255.0

if not %2empty == empty then

route add default %2 endif load fs0:\EFI\Tools\ftpd.efi

:End

Note:

The IP addresses and netmask indicated in this file and in the following example are only examples and must be modified to reflect site network configuration: fs0:\> Netconf 129.182.189.3 129.182.189.1

129.182.189.3

is the <ip address>

129.182.189.1 is the <gateway ip address>

File Transfer Protocol (FTP)

An FTP Client and an FTP Server are provided with the EFI Utilities.

1. Configure the network. See Manual Network Configuration.

2. Load the FTP Server via the EFI load command.

3. Load the FTP Client via the EFI ftp command. This Client supports most ftp directives

(open, get, put, ...). Use the help directive if you need help.

Note:

As the load command does not use the search path to locate protocols, specify the path if it is not in the current working directory and the .efi extension.

load fs0:\efi\tools\ftpd.efi

The FTP Server is now available for use and accepts anonymous connections (one at a time).

Important:

Once the EFI drivers for the TCP/IP, the FTP Server or FTP Client are loaded, you cannot load an Operating System.

To load an Operating System, reset the domain and return to Boot Manager.

Tips and Features for Administrators 5-15

Section III - Customizing PAM Software

This section explains how to:

Set up PAP Unit Users, on page 5-17

Modify Customer Information, on page 5-19

Configure Autocalls, on page 5-20

Set Thermal Units, on page 5-22

Deploy a New PAM Release, on page 5-23

Activate a PAM Version, on page 5-24

Back up and Restore PAM Configuration Files, on page 5-26

5-16 User's Guide

Setting up PAP Unit Users

As Customer Administrator, you must set up user accounts and passwords to control access to the PAP unit.

The Microsoft Windows operating system pre-installed on the PAP unit provides standard security features for controlling access to applications and resources. PAM software security is based on Windows  user management and you are advised to give Windows  administrator rights to at least one member of the PAP Customer Administrator user group.

For further details about user management, refer to the Microsoft Windows documentation on the Bull NovaScale Server System Resource CD.

Note:

You are advised to change the temporary Administrator password (administrator) used for setup purposes and to maintain a detailed record of authorized users.

Predefined PAP User Groups

For optimum security and flexibility, the Microsoft Windows software environment is delivered with two predefined Customer user groups:

Pap_Customer_Administrators Group (CA)

This group is designed for customer representatives responsible for the overall management, configuration, and operation of the system. Members of the Customer Administrator group are allowed to configure and administrate the server and have full access to the PAM

Domain Manager, Hardware Monitor, History Manager and Configuration Tasks menus, as shown in Table 34.

Pap_Customer_Operators (CO)

This group is designed for customer representatives responsible for the daily operation of the system. Members of the Customer Operator group are allowed to operate the server and have partial access to the Domain Manager and History Manager menus, as shown in Table

34.

Notes:

• Group membership also conditions which Event Messages a user will receive via the PAM

Web interface. See Setting up Event Subscriptions, on page 5-134.

• The predefined Customer user groups have been designed to suit the needs of most

Administrator and Operators. Contact your Customer Service Engineer if you require a customized user group.

Warning:

The two predefined Support user groups:

- Pap_Support_Administrators

- Pap_Support_Operators are reserved EXCLUSIVELY for authorized Customer Service Engineers in charge of monitoring, servicing, and upgrading the system.

Tips and Features for Administrators 5-17

PAM Tools

Domain Manager

Hardware Monitor

History Manager

Configuration Tasks

Status Pane

Associated Actions

Synchronize domains

View/load a domain configuration scheme

Add domains to the current domain configuration

Replace the current domain configuration

Delete domains from the current domain configuration

Save the current domain configuration snapshot

Power on/off and reset domains

Forcibly power off domains

Perform a domain memory dump

View domain settings

View domain configuration, resources and status

View domain BIOS info and version

View domain fault lists

View domain power and request logs

View domain powering sequences

View hardware functional/presence status

View detailed hardware status information

Use the hardware Search engine

Exclude/include hardware components

View current PAM Web site user information

View PAM version information

View system history files, messages and fault lists

Manually archive system history files

View/delete system history archives

View user history files

Manually archive user history files

View/delete user history archives

View/modify customer information

Create/modify/delete domain schemes and identities

Manage Logical Units

Check/update FC HBA World Wide Names

Limit access to hardware resources

Modify the system history automatic archiving policy

Create/delete user histories

Modify the user history automatic archiving policy

Customize the event messaging system

View/ modify PAM parameters

Display/modify autocall parameters

Exclude / include ring connections

View/acknowledge WEB event messages

Check system functional status/CSS availability

CA = Customer Administrator / CO = Customer Operator

Table 34.

User access to PAM features

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CA CO

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

5-18 User's Guide

Modifying Customer Information

Customer information is configured during the initial installation procedure, via the PAM configuration setup Wizard. This information is used by PAM software:

• for the PAM Tree display: the name entered in the Site name field will be used for the

PAM tree root node,

• to complete Customer Service Engineer Intervention Reports,

• to configure the Email server used to send messages via the e-mail channel. See Creating

an E-mail Server, on page 5-136.

As Customer Administrator, you may modify this information.

To modify Customer information:

1. From the PAM Tree, click Configuration Tasks → Customer Information.

The Customer Information configuration page opens.

2. Enter the new information and click Save to confirm changes.

Figure 96. Customer Information configuration page

Tips and Features for Administrators 5-19

Configuring Autocalls

The Autocall feature is part of the BULL Remote Maintenance contract. It is used to automatically route system events to the Remote Maintenance Center. Full details are given in the BULL Remote Maintenance Guide.

If your maintenance contract includes the Autocall feature, configure Autocall parameters as follows:

3. Click Configuration Tasks → Autocalls. The Autocalls configuration page opens.

Figure 97. Autocalls Channel Settings control pane

4. Select the Enable Autocalls checkbox.

5. Select the Send Heartbeat checkbox and enter a value "in days" for the autocall channel control in the Period box. Recommended value = 1.

6. Select the autocall dispatch mode :

- Local dispatch mode (default mode) sends autocalls to the local target directory indicated under Local Settings,

- FTP dispatch mode sends autocalls to the server indicated under FTP Settings.

7. If Local dispatch mode (default mode) is selected, complete the Local Settings field with the following information:

Field Explanation

Local target directory Default GTS directory used to store autocalls.

Value c:\gts\session

5-20 User's Guide

8. If FTP dispatch mode is selected, complete the FTP Settings fields with the following information:

Field

Server name

Explanation

Remote Maintenance Center server IP address

Server port Default server port

Target directory Default server directory

Login

Password

Declared authorized user name

Declared authorized user password

Passive mode FTP connection mode

Value

127.0.0.1

X

X

21

/autocall check box

9. If a modem connection is to be used: a. From the PAP Unit Microsoft Windows desktop, configure the dial-up connection

(Control Panel → Phone and Modem Options).

b. From the PAM Autocalls Control Pane, select the Use modem connection checkbox.

c. Use the Connection name drop-down menu to select the required modem connection.

d. Complete the User name and Password fields with the declared authorized user name and user password.

Tips and Features for Administrators 5-21

Setting Thermal Units

By default, PAM software displays thermal measurements in degrees Celsius. As Customer

Administrator, you may change the default setting to degrees Fahrenheit.

To change PAM thermal units:

1. Click Configuration Tasks → PAM. The PAM Configuration control pane opens.

2. Click the Celsius or Fahrenheit radio button, as required.

3. Click Save. A green icon appears in the top left corner of the control pane to confirm the change.

Figure 98. PAM configuration control pane

5-22 User's Guide

Deploying a PAM Release

As Customer Administrator, you can re-deploy a PAM release on a backup PAP Unit by running the PAM Installation package x.y.z. msi (x.y.z being the PAM version e.g. 2.1.9 ) file.

Important:

This procedure should only be used to re-deploy a current PAM Release on a backup PAP

Unit. PAM software can only be updated by authorized Customer Service Engineers.

To install a PAM Release:

1. From the local PAP unit console, power down all server domains and close the current

PAM session.

2. From the default PAM Installation directory, double click the .msi file to launch the PAM

Installation InstallShield Wizard.

3. Select Complete to install all program features and to accept the default path for the installation folder:

<WinDrive>:\Program Files\BULL\PAM\installation\<Release Version>

(e.g. d:\Program Files\BULL\PAM\installation\ 2.1.9 ).

or, select Custom to select program features and to define a path for the installation folder.

Figure 99. PAM Installation InstallShield Wizard

Note:

This path is the repository for activation files. NEVER delete this folder after activation as it is required to repair and re-activate the release.

4. Click Install to begin setup.

5. Select the Launch PAM Activation utility checkbox and click Finish. The PAM Activation utility is automatically launched.

The PAM Activation icon is installed on the PAP unit desktop and the Platform

Administration and Maintenance program group, giving access to the PAM Activation and

PAP Configuration executable files, is installed in the Program Files directory.

Tips and Features for Administrators 5-23

Activating a PAM Version

The PAM InstallShield Wizard automatically creates a shortcut to the PAM Activation utility on the PAP unit desktop that can be used at any time to activate an installed PAM Version.

Note:

A previous PAM Version can be re-activated at any time, in the event of a problem with the current release.

To activate / re-activate a PAM Version:

1. From the local PAP unit console, power down all server domains and close the current

PAM session.

2. From the PAM Activation utility on the Microsoft Windows desktop, select the required

PAM Version and click Activate to launch the PAM Activation InstallShield Wizard.

3. Select Complete to accept the default paths for the PAM Release and PAM Site Data folders:

The default PAM Release directory for all the files delivered as part of PAM software is:

<WinDrive>:\Program Files\BULL\PAM\<Release Version>

(e.g. d:\Program Files\BULL\PAM\).

The default PAM Site Data directory for all the files produced by PAM software (history files, configuration files) concerning Customer site definition and activity is:

<WinDrive>:\Program Files\BULL\PAM\PAMSiteData\<DataCompatibilityRelease>

(e.g. d:\Program Files\BULL\PAM\PAMSiteData\1).

5-24

Figure 100. PAM Activation InstallShield Wizard

Important:

PAM releases use the same data directory to ensure configuration consistency.

Before activating / re-activating a PAM Version, ensure that the <Data Compatibility Release> level of deployed releases is compatible.

If it is NOT compatible, PAM configuration options (e.g. Event subscription options, ... ) may be lost.

User's Guide

4. Click Install to begin activation.

5. Select the Launch PAP Configuration utility checkbox if you want to configure or reconfigure PAP unit settings. Otherwise, click OK to complete activation.

6. From the local PAP unit console, right click the Microsoft Internet Explorer icon on the desktop and click Properties → General → Delete Files to delete all the files in the

Temporary Internet Folder.

7. Launch a new PAM session.

Important:

Notify all authorized users, connecting to PAM from a remote console, that a new PAM

Version has been activated and request them to: a. Close their current PAM session.

b. Delete all the files in their Temporary Internet Folder.

c. Launch a new PAM session.

Tips and Features for Administrators 5-25

Backing Up and Restoring PAM Configuration Files

As Customer Administrator, you are advised to regularly save PAM configuration data to a removable media or to a network directory so that it can be rapidly restored in the event of

PAP unit failure.

PAM software can be deployed on any standard PC running the appropriate version of

Microsoft Windows and you can restore your configuration data to rebuild your working environment.

To ensure carefree, reliable and regular configuration data backup, the Bull NovaScale

Server Resource CD contains two scripts, PamBackupData.js and PamRestoreData.js, that can be scheduled to run via the Microsoft Windows Task Scheduler to save and restore PAM configuration data.

Notes:

• PAM configuration data is automatically saved to the default PAM Site Data directory on the PAP unit:

<WinDrive>:\Program Files\BULL\PAM\PAMSiteData\<DataCompatibilityRelease>

• The PamBackupData.js and PamRestoreData.js scripts are stored in the PAM Site Data directory on the PAP unit:

<WinDrive>:\Program Files\BULL\PAM\PAMSiteData\ReleaseData\Utilities

Backing Up PAM Configuration Files

To create a Microsoft Windows automatic backup task:

1. Select or create the local or network directory to be used for saving configuration data, e.g. <MyPamBackupDirectory>.

2. Create a local directory for the PamBackupData.js and PamRestoreData.js script files, e.g. <MyPamBackupTools>.

3. Copy the PamBackupData.js and PamRestoreData.js script files into the

<MyPamBackupTools> directory.

4. Create a Text File and enter the following command line:

Cscript PamBackupData.js <MyPamBackupDirectory>

5. Save the Text File as a batch file with a .BAT extension, e.g. <MyPamBackupCommand>.bat.

6. Click Control Panel → Scheduled Tasks → Add Scheduled Task to open the Task Scheduler wizard and follow the instructions. PAM configuration data will be automatically saved at the interval indicated in the wizard.

5-26 User's Guide

Restoring PAM Configuration Data

Warning:

The same PAM software release must be deployed on the PAP unit and on the backup PC to allow data restoration.

See Deploying a New PAM Release, on page 5-23 and

Activating a PAM Version, on page

5-24.

PAM releases use the same data directory to ensure configuration consistency.

Before activating / re-activating a PAM Version, ensure that the <DataCompatibilityRelease> level of deployed releases is compatible.

Warning:

The script file stops and restarts the PAM application before restoring PAM configuration data.

To restore PAM configuration data:

7. From the Microsoft Windows desktop, open a command window. Browse to the

<MyPamBackupTools> directory containing the script files and enter the following command line:

Cscript PamRestoreBackupData.js <MyPamBackupDirectory>

Saved PAM configuration data is restored.

Tips and Features for Administrators 5-27

Section IV - Configuring Domains

Important:

This section describes domain configuration and management tools that are reserved for use with partitioned servers and extended systems. Please contact your BullSales Representative for sales information.

This section explains how to:

Partition your Server, on page 5-29

Assess Configuration Requirements, on page 5-31

Manage Domain Configuration Scheme, on page 5-33

Update Test Schemes, on page 5-49

Create, Edit, Copy, Delete a Domain Identity, on page 5-50

Manage LUNs (Servers Not Connected to a SAN), on page 5-57

Manage LUNs (Servers Connected to a SAN), on page 5-55

Check and Update Fibre Channel HBA World Wide Names, on page 5-64

Limit Access to Hardware Resources, on page 5-66

Create a Mono-Domain Scheme using all Server Resources, on page 5-69

Create a Mono-Domain Scheme using a Part of Server Resources, on page 5-83

Create a Multi-Domain Scheme using all Server Resources, on page 5-96

Create a Multi-Domain Scheme using a Part of Server Resources, on page 5-111

Configure and Manage Extended Systems, on page 5-125

Prepare a Scheme, Domain Identity, and Hardware Resources Checklist, on page 5-126

5-28 User's Guide

Partitioning your Server

Important:

Reserved for partitioned servers and extended systems. Please contact your Bull Sales

Representative for sales information.

Bull NovaScale Servers are designed around a flexible, cell-based, midplane architecture allowing dynamic partitioning into physically independent domains. A domain is a coherent set of hardware and software resources managed by a single Operating System instance.

The NovaScale 5085 Partitioned Server is designed to operate as one or two hardware-independent SMP systems, or domains.

The NovaScale 5165 Partitioned Server is designed to operate as one, two, three or four hardware-independent SMP systems, or domains.

The NovaScale 5245 Partitioned Server is designed to operate as one or up to six hardware-independent SMP systems, or domains.

The NovaScale 5325 Partitioned Server is designed to operate as one or up to eight SMP systems, or domains.

Note:

Server components and configuration may differ according to site requirements.

At least one IOC and one QBB are required for each server domain.

Partitioning allows you to optimize your server to:

• meet variations in workload - peak / off-peak periods,

• allow different time and date settings,

• use the same environment for tests and production,

• carry out software tests prior to deployment / upgrades,

• reduce downtime for servicing or re-configuration.

PAM software provides you with all the tools and features required to partition and manage your server as independent SMP systems. For easy configuration and optimum use of the physical and logical resources required for simultaneous operation, domains are defined via the Domain Configuration Scheme wizard. From the PAM tree, expand the Configuration

Tasks and Domains nodes to display domain configuration options.

Tips and Features for Administrators 5-29

Figure 101. Schemes and Identites panes

A Domain Configuration Scheme is used to define and manage a set of domains that can be active simultaneously. The Schemes control pane allows you to create, edit, copy, delete, and rename domain configuration schemes and update default test schemes.

A Domain Identity is used to define and manage domain context information.

The Identities control pane allows you to create, edit, copy, and delete domain identities.

The server is delivered with a pre-configured domain configuration scheme called

MyOperationsScheme, allowing you to simultaneously manage and administer all server resources. However, as Customer Administrator, you may want to create other schemes and identities to suit your working environment.

Before proceeding to create a new Scheme and/or new Domain Identities, you are advised to assess your configuration requirements. See Assessing Configuration Requirements, on

page 5-31.

5-30 User's Guide

Assessing Configuration Requirements

Important:

Reserved for partitioned servers and extended systems.

Certain features described below are only available if you are connected to a Storage Area

Network (SAN).

Please contact your Bull Sales Representative for sales information.

At least one IOC and one QBB are required for each server domain.

You can use the following checklist to help you make an accurate plan of how you want to partition and manage your system. For easy planning, you can print a copy of the Scheme,

Domain Identity, and Resources checklist templates provided on page 5-126.

Name

Description

Central Subsystem(s)

Number of Domains

Domain Size

EFI Boot LUNs

Data LUNs *

Fibre Channel Hosts *

I/O Resource Location

Resource Access

Scheme Checklist

What name do I want to use for my Scheme?

Examples:

• MyFullConfigScheme

• MyPartConfigScheme

• MyNightScheme

• MyDayScheme

• MyTest_ProductionScheme

How can I describe my Scheme to reflect its scope?

Examples:

• Central Subsystems included

• Resources used

• Domain Identities used

Which Central Subsystem(s) do I want to use?

How many domains do I need?

How many cells do I want to assign to each domain?

Which EFI boot LUN do I want to use for each domain?

Do I need to create a new EFI boot LUN from the disk subsystem utility before defining my new scheme?

Which data LUNs do I want to assign to each domain?

Do I need to create a new data LUN from the disk subsystem utility before defining my new scheme?

Which fibre channel host do I want to use to access LUNs?

Which cells host the I/O resources I want to use?

Do I want to limit access to certain hardware resources?

* Reserved for systems connected to a Storage Area Network (SAN).

Table 35.

Domain configuration assessment criteria - 1

Tips and Features for Administrators 5-31

Name

Description

Domain Identity Checklist

What name do I want to use for my Domain Identity to reflect the tasks/jobs it will run?

Examples:

• MyDataMiningIdentity

• MyDataBaseIdentity

• MyProductionIdentity

• MyTestIdentity

How can I describe my Domain Identity to reflect its use?

Examples:

• OS and applications

• Time zone

• Boot path

• IP address

• Network name

• URL

• Production / test conditions

Operating System Which OS do I want to run on this domain? Does this OS support assigned hardware (CPUs, DIMMs)?

Domain Network Name Which network name will be used to identify this domain?

Domain IP Address

Domain URL

Multithreading Mode

Which IP address will be used to reach this domain?

Which URL can be used to reach my domain Web site (if any)?

Do the CPUs used by this domain support the multithreading mode?

Do I want to enable the multithreading mode for this domain?

High Memory IO Space Do I need more than 4GB PCI gap space for the PCI boards used by this domain?

Machine Check

Licensing number

Do I want this domain to halt or to automatically reset if a machine check error occurs?

Do I intend to install an application protected by a system serial number on this domain?

Do I want to substitute the physical system serial number with the logical licensing number for optimum flexibility?

Force Halt on Machine

Check Reset

Has my Customer Service Engineer requested me to check this box to troubleshoot my server?

Table 36.

Domain configuration assessment criteria - 2

5-32 User's Guide

Managing Domain Configuration Schemes

Important:

Reserved for partitioned servers and extended systems.

Certain features described below are only available if you are connected to a Storage Area

Network (SAN).

Please contact your Bull Sales Representative for sales information.

What You Can Do

From the Schemes Control pane, you can:

• Create a domain configuration scheme

• Edit a domain configuration scheme

• Copy a domain configuration scheme

• Delete a domain configuration scheme

• Rename a domain configuration scheme

Creating a Domain Configuration Scheme

Pre-requisites

• Required EFI LUNs and Data LUNs must be created from the utility delivered with the storage subsystem.

See Configuring System and Data Disks, on page 5-5.

• SAN LUN and/or Local LUN lists must be updated from the Logical Units page.

See Updating SAN LUNs, on page 5-59 and/or Updating Local LUNs, on page 5-60 and

on page 5-56.

• SAN Fibre Channel HBA World Wide Name (WWN) parameters must be up-to-date.

See Checking and Updating Fibre Channel HBA World Wide Names, on page 5-64.

• Domain Identities can either be created via the Domain Scheme wizard or, independently,

via the Identities configuration page. See Creating a Domain Identity, on page 5-50.

• At least one IOC and one QBB are required for each server domain.

Steps

• Assess requirements

• Create EFI and/or Data LUNs

• Update the LUN lists

• Update Fibre Channel World Wide Name (WWN) parameters*

• Select the Central Subsystem(s)

• Define the number of domains

For each domain in the scheme:

• Select / create a domain identity

• Select an EFI LUN

• Select Data LUNs*

• Link LUNs to the Fibre Channel Host*

• Lock access to hardware resources

* Reserved for systems connected to a Storage Area Network (SAN)

Tips and Features for Administrators 5-33

To create a domain configuration scheme:

1. Assess your configuration requirements. See Assessing Configuration Requirements, on

page 5-31.

2. If required:

- Create EFI and/or Data LUNs from the utility delivered with the storage subsystem. You are advised to use RAID level 1 for EFI LUNs and RAID level 5 for Data LUNs.

- Update the SAN LUN and/or Local LUN lists from the Logical Units page. See

Updating SAN LUNs, on page 5-59 and/or Updating Local LUNs, on page 5-60 and

on page 5-56.

- Update Fibre Channel HBA World Wide Name (WWN) parameters.

3. Click Configuration Tasks → Domains → Schemes in the PAM tree to open the Schemes control pane.

Figure 102. Schemes control pane

5-34 User's Guide

4. Click New in the toolbar to open the Scheme Management dialog.

Scheme Name

Description

Add

Central Subsystem

Name used to identify the scheme.

Brief description of scheme configuration.

Select the Central Subsystem used in the scheme.

Remove

Modify

Remove a Central Subsystem from the scheme.

Select the number of hardware partitions in the scheme.

Domains

Remove

Identity

EFI LUNs

Data LUNs *

Link *

Remove the selected domain from the scheme.

Select a domain identity.

Select an EFI Boot LUN.

Assign Data LUNs to the domain.

Define the fibre channel host to be used to access LUNs.

Lock Hardware Limit access to certain hardware resources.

* Reserved for systems connected to a Storage Area Network (SAN)

Figure 103. Scheme Management dialog

5. Complete the Scheme Name and Description fields, as required. See Assessing

Configuration Requirements, on page 5-31.

6. Click → Add to select the Central Subsystem to be used by the domain configuration scheme. The Central Subystem Configuration dialog opens.

Tips and Features for Administrators 5-35

NovaScale 5085 Server

NovaScale 5165 Server

Note:

If two CSS Module cells are linked by a Chained DIBs icon , you cannot partition this module.

5-36 User's Guide

NovaScale 5245 Server

NovaScale 5325 Server

Figure 104. Scheme Creation and Central Subsystem Configuration dialogs

Note:

If two CSS Module cells are linked by a Chained DIBs icon , you cannot partition this module.

7. In the Central Subsystem list, select the required Central Subsystem.

The graphic representation of the selected Central Subsystem appears in the bottom right part of the window.

Tips and Features for Administrators 5-37

8. Use the Number of Partitions dropdown list to select the required number of hardware partitions (2 in the examples). The partitions appear in the partition list.

9. Click the first partition in the list and select the cells to be included in this partition.

Repeat this step for each partition in the list.

Important:

For optimum performance, selected cells should be contiguous, as shown in the following figure.

Incorrect Correct

Figure 105. Optimizing partitioning

10.Click OK to return to the Scheme Management dialog.

Status icons are red because Domain Identities and EFI LUNs are required to complete domain configuration.

NovaScale 5085 Server

5-38 User's Guide

NovaScale 5165 Server

NovaScale 5245 Server

Tips and Features for Administrators 5-39

NovaScale 5325 Server

Figure 106. Scheme Management dialog - Central Subsystem configured

11.Click Domains -> Identities to open the Identities Management dialog.

Figure 107. Domain Identities list

12.If the required identity is in the list, go to Step 13.

If you want to create a new identity for this domain, click New to open the Create New

Identity dialog. See Creating a Domain Identity, on page 5-50.

13.Select the required identity from the list of available identities and click OK to return to the

Scheme Management dialog. The selected identity is now displayed in the Domain

Identities field.

5-40 User's Guide

14.Click Domains -> EFI LUNs to open the Select EFI LUN dialog.

1

2

1 SAN storage subystem 2 Local storage subsystem

Figure 108. EFI LUN selection list

15.If the required EFI LUN is in the list, go to Step 16.

If the required EFI LUN is not in the list, you must exit the Domain Scheme wizard to

configure the EFI LUN. See Pre-requisites, on page 5-33.

16.Select the required EFI Boot Lun from the list of available Luns and click OK to return to the Scheme Management dialog. The selected LUN is now displayed in the EFI LUNs field.

17.If the EFI LUN is a Local LUN, the Status icon turns green, go to Step 18.

If the EFI LUN is a SAN LUN, the Status icon remains red and the No Link icon appears.

Tips and Features for Administrators 5-41

18.If the EFI LUN is a Local LUN and you do not want to add one or more Data LUNs to the domain, go to Step 28.

If the EFI LUN is a SAN LUN and you do not want to add one or more Data LUNs to the domain, go to Step 22.

If the EFI LUN is a Local or SAN LUN and you want to add one or more SAN Data LUNs to the domain, click Domains -> Data LUNs to open the Select Data LUN dialog.

Figure 109. Select Data LUN dialog - Data luns available list

5-42 User's Guide

19.Select the LUN you want to add to the domain in the Data LUNs available list and click

Details to view LUN parameters, if required.

Name

Description

LUN Number

LUN State

Type

Size

Subsystem Name

Subsystem Model

Serial Number

EFI LUN

Present

Loaded

Allocated

Name given to the LUN when created.

Brief description of the LUN.

Number allocated to the LUN when created.

If the LUN is ready for use, READY is displayed.

LUN configuration mode.

LUN size.

Name of the subsystem containing the LUN.

Type of subystem containing the LUN.

Serial number of the subsystem containing the LUN.

If this box is checked, the LUN is an EFI boot LUN.

If this box is not checked, the LUN is a Data LUN.

If this box is checked, the LUN is detected.

If this box is checked, the LUN is not detected.

If this box is checked, the LUN is loaded in the Domain

Manager Control pane.

If this box is not checked, the LUN is not loaded in the Domain Manager Control pane.

If this box is checked, the LUN is already allocated to a scheme.

If this box is not checked, the LUN is not allocated to a scheme.

Figure 110. View LUN parameters dialog

Tips and Features for Administrators 5-43

20.Click Add. The selected Data LUN is moved to the Data LUNs selected list.

Figure 111. Select Data LUN dialog - Data luns selected list

21.Repeat Steps 19 and 20 for each Data LUN you want to add to the domain and click OK to return to the Scheme Management dialog. Data LUN set is now displayed in the Data

LUNs field.

The Status icon remains red and the No Link icon is displayed. You must now link the selected EFI and Data LUNs to the Fibre Channel Host you want to use to access these

LUNs.

22.Click Domains -> Link to open the Link LUNs to HBA dialog.

Figure 112. Link LUNs to HBA dialog

5-44 User's Guide

23.Select the Redundant checkbox if you want to define two links to the LUN.

Note:

If you select the Redundant mode, you will be informed that dedicated software is required to enable this mode and you will be requested to confirm your choice.

24.Click Set Primary Link to define the main access path to the SAN. The Select HBA dialog opens, allowing you to select the domain PCI slot you want to use to access the LUN.

Figure 113. Select an HBA dialog

25.Select the PCI slot containing the HBA to be used as the primary link to the SAN and click

OK. The primary link is now set.

26.Where applicable, click Set Secondary Link to define the backup access path to the SAN.

Select the PCI slot containing the HBA to be used as the secondary link to the SAN and click OK. The secondary link is now set.

27.Click OK → Apply to return to the Scheme Management dialog. The Status icon turns green and the Linked icon appears.

28.Repeat Steps 11 to 27 for the other domains. All Status icons turn green.

Tips and Features for Administrators 5-45

NovaScale 5085 Server

NovaScale 5165 Server

5-46 User's Guide

NovaScale 5245 Server

NovaScale 5325 Server

Figure 114. Scheme Management dialog

29.If you do not want to functionally limit access to certain hardware elements, go to

Step 30.

If you want to functionally limit domain access to certain hardware elements, click

Domains → Lock Hardware to open the Lock Domain Hardware Resources dialog. See

Limiting Access to Hardware Resources, on page 5-66.

30.Click Save. The domain configuration scheme is now available for domain management.

Tips and Features for Administrators 5-47

Editing a Domain Configuration Scheme

To edit a domain configuration scheme:

1. Assess your configuration requirements. See Assessing Configuration Requirements, on

page 5-31.

2. Click Configuration Tasks → Domains → Schemes in the PAM tree to open the Schemes pane. See Figure 102 above.

3. Select the required scheme from the list.

4. Click Edit in the toolbar to open the Edit Scheme dialog.

Add

Central Subsystem

Click here to add another Central Subsystem to your scheme.

See Creating a Domain Configuration Scheme, on page 5-33.

Click here to remove a Central Subsystem from your scheme.

Remove

Modify

Remove

Identity

EFI LUNs

Data LUNs *

Click here to change the number of hardware partitions in your scheme.

Domains

Click here to remove the selected domain from the scheme.

Click here to select a domain identity.

Click here to select an EFI Boot LUN.

Click here to assign Data LUNs to the domain.

Link * Click here to define the fibre channel host to be used to access LUNs.

Lock Hardware Click here to limit access to certain hardware resources.

* Reserved for systems connected to a Storage Area Network (SAN).

Figure 115. Edit Scheme dialog

5. Make the required changes and click Save. The modified domain configuration scheme is now available for domain management.

5-48 User's Guide

Copying a Domain Configuration Scheme

To copy a domain configuration scheme:

1. Click Configuration Tasks → Domains → Schemes in the PAM tree to open the Schemes pane. See Figure 102 above.

2. Select the required scheme from the list.

3. Click Copy in the toolbar. The Copy Scheme dialog opens.

4. Enter a name for the new scheme and click OK. The new domain configuration scheme is now available for domain management.

Deleting a Domain Configuration Scheme

To delete a domain configuration scheme:

1. Click Configuration Tasks → Domains → Schemes in the PAM tree to open the Schemes pane. See Figure 102 above.

2. Select the required scheme from the list.

3. Click Delete in the toolbar. You are requested to confirm scheme deletion.

4. Click OK to confirm. The domain configuration scheme is removed from the Schemes List and is no longer available for domain management.

Renaming a Domain Configuration Scheme

To rename a domain configuration scheme:

1. Click Configuration Tasks → Domains → Schemes in the PAM tree to open the Schemes pane. See Figure 102 above.

2. Select the required scheme from the list.

3. Click Rename in the toolbar.

4. Enter a new name for the scheme and click OK. The renamed domain configuration scheme is now available for domain management.

Updating Default Schemes

The Domain Wizard allows you to automatically generate and update a set of Default

Schemes. These default schemes take into account all the hardware in your configuration.

You may need to update your default schemes after a service intervention entailing the addition/removal of hardware elements.

To update default schemes:

1. Click Configuration Tasks → Domains → Schemes in the PAM tree to open the Schemes pane. See Figure 102 above.

2. Click Schemes Update in the toolbar. Default schemes are automatically updated.

Tips and Features for Administrators 5-49

Creating, Editing, Copying, Deleting a Domain Identity

Important:

Reserved for partitioned servers and extended systems. Please contact your Bull Sales

Representative for sales information.

Note:

Domain Identities can either be created via the Domain Configuration Scheme wizard or, independently, via the Identities configuration page. See Creating a Domain Configuration

Scheme, on page 5-33.

Creating a Domain Identity

To create a domain identity:

1. Assess your configuration requirements. See Assessing Configuration Requirements, on

page 5-31.

2. Click Configuration Tasks → Domains → Identities in the PAM tree to open the Identities

Management page.

Figure 116. Identities List page

5-50 User's Guide

3. Click New in the toolbar to open the Create New Identity dialog.

Identity Name

Description

Operating System and Version

Network Name

IP Address

URL

Name reflecting the tasks/jobs to be run by the domain.

Brief description reflecting domain use.

OS and OS version to be run on this domain.

Note:

Check that the selected OS supports assigned hardware

(CPUs, DIMMs)?

Network name used to identify this domain.

IP address used to reach this domain.

URL used to reach the domain Web site (if any).

Figure 117. Create New Identity dialog

4. Complete the Name, Description, Domain Settings and Management Parameters fields as required.

Tips and Features for Administrators 5-51

5. Click Advanced Settings to open the Advanced Identity Settings dialog.

CPU Parameters

High Memory IO Space Enable / disable extended PCI gap memory space.

Note:

Only use if this domain uses PCI boards requiring more than 4GB PCI gap space.

Compatibility problems may arise under Windows.

IO Memory Space Optimization Enable / disable IO space overlap.

Note:

Check this box to increase the number of PCI boards supported by the domain (from 14 to 29 maximum).

Licensing Number

Enable / disable multithreading.

Note:

Check that the CPUs used by this domain support the multithreading mode.

Machine Check

Automatic Restart

Licensing number used by protected applications, created by adding a two digit extension to the system serial number.

Enable / disable substitute mode.

Note:

Check this box to substitute the physical system serial number with the logical licensing number for optimum flexibility.

Enable / disable automatic domain reset when a machine check error occurs.

Note:

Check this box when requested by your Customer Service

Engineer.

Enable / disable automatic domain restart after a mains power failure.

Note:

Check this box to automatically restart the domain (if previously running or EFI started) after a mains power failure.

Figure 118. Advanced Identity Settings dialog

5-52 User's Guide

6. Complete the Advanced Identity Settings dialog fields as required: a. CPU Parameters:

. Select Multithreading Mode if you want this domain to use multithreading features

(if the CPUs used by the domain support the multithreading mode)

. Select Monothreading Mode if you do not want this domain to use multithreading features or if the CPUs used by the domain do not support the multithreading mode.

b. High Memory IO Space:

Note:

Please read the documentation delivered with your PCI boards for details about features and requirements.

Select Enable PCI gap above 4 GB if the PCI boards used by the domain require more than 4 GB PCI gap space.

c. IO Memory Space Optimization

Note:

Please read the documentation delivered with your PCI boards for details about features and requirements.

Select Enable IO Space Overlap if you need to increase the number of PCI boards supported by the domain (from 14 to 29 maximum).

Warning:

The following conditions must be met before using this mode:

. The total IO space required by a given PCI bus must be less than 2KB.

. Segments (sets of one or two PCI buses) are numbered in ascending order. The number of Type 1 segments (using only one PCI bus) and Type 2 segments (using both PCI buses) must be even. For example,

Allowed: Type 1 followed by Type 2

Not allowed: Type 1 followed by Type 2followed by Type 1.

d. Licensing Number:

Note:

Please read the documentation delivered with your application for details about licensing requirements.

. Select a system Serial Number from the scroll-down list and add a two digit extension to automatically create the Licensing Number to be used by protected applications running on this domain.

. Select Substitute Mode if you want to substitute the physical system serial number with the logical licensing number for optimum flexibility.

e. If requested by your Customer Service Engineer, select Force Halt on Machine Check

Reset to halt the domain when a machine check error occurs.

Note:

If this box is NOT checked, the domain will automatically reset when a machine check error occurs.

f. Automatic Restart:

. Check this box to automatically restart the domain (if previously running or EFI started) after a mains power failure.

Tips and Features for Administrators 5-53

Note:

An error message (2B2B221F) may be displayed although the domain has been successfully restarted. This error message, generated following the loss of the mains power supply, is not significant.

7. Click OK. The new identity appears in the Identities List page and can be applied to a hardware partition via the Domain Configuration Scheme wizard.

Editing a Domain Identity

To modify domain identity settings, management parameters and/or description:

1. Assess your configuration requirements. See Assessing Configuration Requirements, on

page 5-31.

2. Click Configuration Tasks → Domains → Identities in the PAM tree to open the Identities

Management page. See Figure 116 above.

3. Select the required identity from the list.

4. Click Edit in the toolbar. The Edit an Identity dialog opens, allowing you to modify domain identity settings, management parameters and/or description. See Figure 117 above.

5. Change settings as required.

6. Click OK to confirm the modification.

Copying a Domain Identity

To copy a domain identity:

1. Click Configuration Tasks → Domains → Identities in the PAM tree to open the Identities

Management page. See Figure 116 above.

2. Select the required identity from the list.

3. Click Copy in the toolbar. The Copy Identity dialog opens.

4. Enter the name for the new identity and click OK to confirm.

5. The new identity appears in the Identities List page and can be applied to a hardware partition via the Domain Configuration Scheme wizard.

Deleting a Domain Identity

Important:

If a Domain Identity is used in a Scheme, it cannot be deleted.

To delete a domain identity:

1. Click Configuration Tasks → Domains → Identities in the PAM tree to open the Identities

List page. See Figure 116 above.

2. Select the required identity from the list.

3. Click Delete in the toolbar and click OK to confirm. The selected identity is removed from the Identities List.

5-54 User's Guide

Managing Logical Units (Servers Not Connected to a SAN)

Your server is delivered with default EFI Boot LUNs. You can use the software delivered with your storage subsystem to define data LUNs.

What You Can Do

• Clear, Load, Save NVRAM Variables

• Update the Local LUN Lists

To open the Logical Units management page:

1. Click Configuration Tasks -> Domains -> LUNs in the PAM tree.

Name

EFI

In Use in Domain

In Use in Scheme

NVRAM

Description

Default LUN name

EFI

This LUN is a boot LUN.

DATA

This LUN is a data LUN.

Yes

This LUN is used by a domain currently loaded in the Domain Manager Control pane.

No

This LUN is not used by a domain currently loaded in the Domain

Manager Control pane.

Yes

This LUN has been allocated to a domain within a Domain Configuration Scheme.

No

This LUN has not been allocated to a domain within a Domain Configuration Scheme.

Yes

NVRAM variables have been saved for this LUN.

No

NVRAM variables have not been saved for this LUN.

Default description, indicating LUN location (Central Subsystem name and Cell).

Figure 119. Logical Units page - servers not connected to a SAN

Tips and Features for Administrators 5-55

Updating the Local LUN Lists

The lists of available local LUNs are automatically created when a Central Subsystem is declared and/or added. You can update the lists of available local LUNs at any time to reflect configuration changes.

To update the local LUN lists:

1. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

2. Click Update. When requested, click OK to confirm. The new LUN lists are displayed in the Logical Units page.

Clearing, Loading, Saving NVRAM Variables

NVRAM variables are available for each EFI boot LUN. According to requirements, these variables can be cleared, saved and/or loaded.

1. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

2. Select the required LUN from the list of available EFI Boot LUNs and click NVRAM. The

NVRAM Variables dialog opens.

a. Click Clear to clear displayed NVRAM variables. When requested, click OK to confirm.

b. Click Save to save NVRAM variables for the selected EFI Boot LUN (currently used by an active domain). When requested, enter the name of the file to which NVRAM variables are to be saved. The NVRAM variables file is stored in the PAM SiteData directory.

c. Click Load to load previously saved NVRAM variables from the PAM SiteData directory.

5-56 User's Guide

Managing Logical Units (Servers Connected to a SAN)

Important:

Certain features described below are only available if you are connected to a Storage Area

Network (SAN).

Please contact your Bull Sales Representative for sales information.

What You Can Do

• Update SAN LUN Lists

• Declare Local LUNs

• Delete Local LUNs

• Edit LUNs

• Rename LUNs

• Clear, Load, Save NVRAM Variables

Note:

EFI LUNs and Data LUNs must be created from the utility delivered with the storage

subsystem. See Configuring System and Data Disks, on page 5-5.

To open the Logical Units management page:

1. Click Configuration Tasks -> Domains -> LUNs in the PAM tree.

1

SAN storage subystem

2

Local storage subsystem

Notes:

• EFI Boot LUNs, on which Operating Systems are installed, are listed at the top of the pane.

Tips and Features for Administrators 5-57

• Data LUNs, on which data can be stored, are listed at the bottom of the pane.

Command Bar

SAN Update

Edit LUN

Update the lists of SAN LUNs.

Modify the LUN name, description, and change a Data LUN into an EFI LUN and vice-versa.

Rename LUN

NVRAM

Modify the LUN name.

Clear, load and save EFI Boot LUN NVRAM variables.

Declare Local LUN Declare a new local LUN.

Delete Local LUN Delete a non-allocated local LUN.

LUN List

Name

LUN Number

Type

Capacity

Loaded

Allocated

Description

LUN name.

Number allocated to the LUN.

RAID configuration type.

RAID1 is recommended for EFI LUNs and RAID5 for Data LUNs.

LUN storage capacity.

Yes

LUN used by a currently loaded domain.

No

LUN not used by a currently loaded domain.

Yes

LUN allocated to a domain within a Domain Configuration

Scheme.

No

LUN not allocated to a domain within a Domain Configuration

Scheme.

Description, indicating LUN location (Central Subsystem name and Cell and/or storage subsystem name).

Figure 120. Logical Units page - servers connected to a SAN

5-58 User's Guide

Updating SAN LUN Lists

Important:

Reserved for systems connected to a Storage Area Network (SAN).

Please contact your Bull Sales Representative for sales information.

When new LUNs are added to / removed from your Storage Area Network, they can be automatically added to / removed from the list of available LUNs by using the PAM SAN

Update command, which allows you to update the lists of available LUNs on the SAN at any time.

Notes:

• This command CANNOT be used to update the lists of local LUNs.

• This command is automatically performed when a PAM session is launched on the PAP unit and when a disk subsystem change takes place.

• When a new LUN is found, PAM considers it as a Data LUN by default. If you want to change this LUN into an EFI Boot LUN, use Edit LUN.

To update the lists of available SAN LUNs:

1. Create the required LUNs from the utility delivered with the storage subsystem(s).

2. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

3. Click SAN Update. A confirmation dialog opens.

4. Click Yes to update the lists of available LUNs. The SAN Update Progress Bar is displayed.

Figure 121. SAN Update progress bar

Once the process is complete, the LUN lists are updated to reflect configuration changes.

Tips and Features for Administrators 5-59

Declaring Local LUNs

When you create a new LUN via the software delivered with your local storage subsystem, you must also declare this new LUN by using the PAM Declare Local LUN command.

Note:

This command CANNOT be used to declare new SAN LUNs.

To update the list of available local LUNs:

1. Create the required LUNs from the utility delivered with the storage subsystem(s).

2. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

3. Click Decclare local LUN to open the Declare Local LUN dialog.

Figure 122. Declare Local LUN dialog

4. Use the Central Subsystem drop-down menu to select the Central Subsystem to which the

LUN is connected.

5. Use the Available Cell drop-down menu to select the cell to which the LUN is connected.

6. Enter the name given to the LUN in the LUN Name field with a brief description.

7. Select the EFI LUN or DATA LUN radio button, as required and click Create. The list of available local LUNs is updated.

5-60 User's Guide

Deleting Local LUNs

Notes:

• A LUN CANNOT be deleted if it is allocated to a Scheme.

To delete a LUN:

1. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

2. Select the required LUN from the lists of available local LUNs and click Delete LUN to open the Delete LUN dialog.

Figure 123. Delete LUN dialog

3. Click Yes to confirm. The LUN is removed from the list of available LUNs.

Tips and Features for Administrators 5-61

Editing LUNs

Important:

Reserved for systems connected to a Storage Area Network (SAN).

Please contact your Bull Sales Representative for sales information.

Notes:

• A LUN CANNOT be edited if it is allocated to a Scheme.

• The NVRAM button is NOT ACCESSIBLE if no NVRAM variables are available for the selected LUN.

If required, you can modify the EFI / Data LUN names, description, NVRAM variables, and/or change a Data LUN into an EFI LUN or vice-versa.

To edit a LUN:

1. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

2. Select the LUN you want to modify from the lists of available LUNs and click Edit LUN to open the Edit LUN dialog.

Figure 124. Edit LUN dialog

3. Modify LUN parameters as required: a. Enter a new name in the Name field if you want to change the LUN name.

b. Enter a new description in the Description field if you want to change the LUN description.

c. Select the EFI LUN checkbox if you want to change a Data LUN into an EFI LUN.

d. Deselect the EFI LUN checkbox if you want to change an EFI LUN into a Data LUN.

4. Click OK to apply changes.

5-62 User's Guide

Renaming LUNs

Important:

Reserved for systems connected to a Storage Area Network (SAN).

Please contact your Bull Sales Representative for sales information.

Note:

A LUN CANNOT be renamed if it is allocated to a Scheme.

To rename a LUN:

1. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

2. Select the LUN you want to rename from the lists of available LUNs and click Rename

LUN to open the Rename LUN dialog.

Figure 125. Rename LUN dialog

3. Enter the new name and click OK to apply the change.

Clearing, Loading, Saving NVRAM Variables

NVRAM variables are available for each EFI boot LUN. According to requirements, these variables can be cleared, saved and/or loaded.

Note:

NVRAM variables can only be saved when the corresponding domain is active.

To clear, save and/or load NVRAM variables:

1. Click Configuration Tasks → Domains → LUNs in the PAM tree to open the Logical Units page.

2. Select the required LUN from the list of available EFI boot LUNs and click NVRAM. The

NVRAM Variables dialog opens: a. Click Clear to clear displayed NVRAM variables. When requested, click OK to confirm.

b. Click Save to save NVRAM variables for the selected LUN (currently used by an active domain). When requested, enter the name of the file to which NVRAM variables are to be saved. The NVRAM variables file is stored in the PAM SiteData directory.

c. Click Load to load previously saved NVRAM variables from the PAM SiteData directory.

Tips and Features for Administrators 5-63

Checking and Updating Fibre Channel HBA World Wide Names

Important:

Reserved for servers and connected to a Storage Area Network (SAN).

Please contact your Bull Sales Representative for sales information.

To control LUN access, Bull NovaScale Servers use LUN masking at Host Bus Adapter (HBA) driver level. Each Fibre Channel HBA driver contains a masking utility using the World Wide

Name (WWN) to limit LUN access. As a result, users are only aware of the LUNs to which they have access.

Whenever you add, change or move a Fibre Channel HBA, you must update the corresponding World Wide Name (WWN) parameters via the PAM interface.

To update an HBA World Wide Name:

1. Click Configuration Tasks -> Domains -> HBAs in the PAM tree.

2. Expand the required Central Subsystem node down to the IOC housing the HBA concerned.

3. Select the IOC. The HBA Worldwide Name page opens.

Figure 126. HBA Worldwide Name page

5-64 User's Guide

4. Double-click the required PCI board to update the WWN. The Modify PCI HBA

Worldwide Name dialog opens.

Figure 127. Modify PCI HBA Worldwide Name dialog

5. Enter the WWN supplied with the HBA and click Save to apply changes.

Tips and Features for Administrators 5-65

Limiting Access to Hardware Resources

You can functionally limit access to certain hardware elements. Locked elements can no longer be accessed by the current domain, but are still physically available for access by other domains. Previously locked elements can be unlocked so that they can be accessed by the domain.

Notes:

• The domain must be INACTIVE before configuration changes can be made.

• Hardware locking / unlocking is only taken into account at the next domain power ON.

• Hardware components to be functionally included (unlocked) in the domain at the next domain power ON are marked with a yellow icon in the Lock Request column in the

Domain Hardware Details page.

• Hardware components to be functionally excluded (locked) from the domain at the next domain power ON are marked with a red / yellow icon in the Lock Request column in the Domain Hardware Details page.

See Viewing Domain Configuration, Resources and Status, on page 3-35.

The following domain hardware elements can be locked / unlocked:

QBB Each domain must comprise at least one QBB.

CPU

IOCs

Each QBB must comprise at least one CPU.

If all CPUs are locked from a QBB, the QBB itself is locked.

When a domain comprises more than one cell (therefore more than one

IOC), the Master IOC is the one hosting the boot disk. The other IOCs in the domain are Slave IOCs.

Slave IOCs can be safely locked from a domain, but connected peripherals will no longer be accessible.

Note:

If the Master IOC is locked, local system disks may no longer be accessible and the domain may not power up.

IOC HubLink

s

All IOC HubLinks can be safely locked from a domain, but connected peripherals will no longer be accessible.

IOC HubLinks are organized as follows:

HubLink_1 controls PCI Slots 1 & 2

HubLink_2 controls PCI slots 3 & 4

HubLink_3 controls PCI slots 5 & 6

Note:

If Master IOC HubLink_1 is locked, local system disks may no longer be accessible and the domain may not power up.

PCI Slots All PCI slots not connected to a boot disk can be safely locked from a domain, but connected peripherals will no longer be accessible.

Note:

If Master IOC PCI Slots 1, 2 are locked, system disks may no longer be accessible and the domain may not power up.

Table 37.

Hardware locking options

Note:

Slave IOLs can be safely locked from a domain, but connected peripherals will no longer be accessible.

If the Master IOL is locked, the domain will not power up.

5-66 User's Guide

Locking / Unlocking Hardware Elements

To lock / unlock a domain hardware element:

1. Open the Lock Domain Hardware Resources dialog: a. If you are configuring a domain scheme:

From the Scheme Management dialog, select the required domain and click Lock

Hardware.

b. If you want to edit a previously defined domain scheme:

. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Schemes → Edit.

. Select the required domain and click Lock Hardware

Figure 128. Lock domain hardware resources dialog

2. Expand the component tree to view the hardware element you want to lock / unlock.

3. Select the corresponding checkbox to lock the element or deselect to unlock a previously locked element.

Tips and Features for Administrators 5-67

Figure 129. Lock domain hardware resources dialog - PCI slot selected

4. Click OK → Apply to return to the Schemes Management pane.

5-68 User's Guide

Creating a Mono-Domain Scheme Using All Server Resources

Notes:

• A domain configuration scheme can include more than one Central Subsystems. If you have more than one Bull NovaScale Server, see Configuring and Managing Extended

Systems, on page 5-125.

• For more information about scheme configuration options, refer to:

- Assessing Configuration Requirements, on page 5-31

- Creating a Domain Configuration Scheme, on page 5-33

- Creating a Domain Identity, on page 5-50

The configuration criteria set out in the following tables is used to illustrate this example:

NovaScale 5085 Server

Scheme

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Data LUNs (SAN only)

MyBusinessScheme

Mono-domain, Cells 0 & 1, Boot 0Lun0, MyBusiness-1

MYSERVER-00

1

2 cells: Cell0 & Cell1

SAN: FDA1300 LUN1

SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

Secondary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC0 mandatory, 0IOC1 optional

All resources unlocked

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

Domain Identity

MyBusiness-1

Time zone: Central America

Windows

MyBusiness-1Net

123.123.12.1

http://www.MyBusiness-1Web.com

Monothreading mode

High memory IO space Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/11

Disabled

Disabled

Table 38.

Scheme configuration criteria - example 1 - mono-module server

Tips and Features for Administrators 5-69

NovaScale 5165 Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Scheme

MyBusinessScheme

Mono-domain, Cells 0, 1, 2 & 3, Boot 0Lun0, MyBusiness-1

MYSERVER-01

1

4 cells: Cell0, Cell1, Cell2 & Cell 3

SAN: FDA1300 LUN1

Data LUNs (SAN only)

Resource access

SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

Secondary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

IO resource location 0IOC0 mandatory, 0IOC1, 1IOC0, & 1IOC1 optional

All resources unlocked

Domain Identity

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

MyBusiness-1

Time zone: Central America

Windows

MyBusiness-1Net

123.123.12.1

http://www.MyBusiness-1Web.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/11

Disabled

Disabled

Table 39.

Scheme configuration criteria - example 1 - 2 modules server

5-70 User's Guide

NovaScale 5245 Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Scheme

MyBusinessScheme

Mono-domain, Cells 0 to 5, Boot 0Lun0, MyBusiness-1

MYSERVER-02

1

6 cells: Cell0 to Cell5

SAN: FDA1300 LUN1

Data LUNs (SAN only)

Resource access

SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

Secondary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

IO resource location 0IOC0 mandatory, 0IOC1, 1IOC0, 1IOC1, 2IOC0 &

2IOC1 optional

All resources unlocked

Domain Identity

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

MyBusiness-1

Time zone: Central America

Windows

MyBusiness-1Net

123.123.12.1

http://www.MyBusiness-1Web.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/11

Substitute mode

Halt on machine check reset

Disabled

Disabled

Table 40.

Scheme configuration criteria - example 1 - 3 modules server

Tips and Features for Administrators 5-71

NovaScale 5325 Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Scheme

MyBusinessScheme

Mono-domain, Cells 0 to 7, Boot 0Lun0, MyBusiness-1

MYSERVER-03

1

8 cells: Cell0 to Cell 7

SAN: FDA1300 LUN1

Data LUNs (SAN only)

Resource access

SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

Secondary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

IO resource location 0IOC0 mandatory, 0IOC1, 1IOC0, 1IOC1, 2IOC0,

2IOC1, 3IOC0 & 3IOC1 optional

All resources unlocked

Domain Identity

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

MyBusiness-1

Time zone: Central America

Windows

MyBusiness-1Net

123.123.12.1

http://www.MyBusiness-1Web.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/11

Substitute mode

Halt on machine check reset

Disabled

Disabled

Table 41.

Scheme configuration criteria - example 1 - 4 modules server

5-72 User's Guide

To create a mono-domain scheme using all server resources:

1. Check that the required hardware resources are available (at least one IOC and one

QBB are required for each server domain) and that the domain Operating System supports the required hardware resources (CPUs, DIMMs, ...).

2. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Schemes to open the Schemes Management pane.

3. Click New to open the Scheme Creation dialog.

4. Complete the Scheme and Description fields.

Figure 130. Scheme creation dialog - example 1

Tips and Features for Administrators 5-73

5. Click Central Subsystem -> Add to select the Central Subsystem to be used by the domain configuration scheme. The Central Subsystem Configuration dialog opens.

NovaScale 5085 Partitioned Server

NovaScale 5165 Partitioned Server

5-74 User's Guide

NovaScale 5245 Partitioned Server

NovaScale 5325 Partitioned Server

Figure 131. Central Subsystem configuration dialog - example 1

6. In the Central Subsystem list, select the required Central Subsystem.

The graphic representation of the selected Central Subsystem appears in the bottom right part of the window.

Tips and Features for Administrators 5-75

7. To create a mono-domain scheme, in the Number of Partitions dropdown list select

1 hardware partition.

8. To configure the partition in order to use all server resources, in the Central Subsystem graphic representation select all the cells.

9. Click OK to return to the Scheme Management dialog.

The Status icon is red because a Domain Identity and an EFI LUN are required to complete domain configuration.

NovaScale 5085 Partitioned Server

NovaScale 5165 Partitioned Server

5-76 User's Guide

NovaScale 5245 Partitioned Server

NovaScale 5325 Partitioned Server

Figure 132. Scheme Management dialog - example 1

10.In the partition list, double-click the empty cell of the P1 line and the Domain Identities column.

The Identity List dialog opens.

Tips and Features for Administrators 5-77

Figure 133. Identity list dialog - example 1

11.If the required identity is in the list, go to Step 16.

If you want to create a new identity for this domain, click New to open the Create New

Identity dialog. See Creating a Domain Identity, on page 5-50 for details.

Figure 134. Create new identity dialog - example 1

12.Complete the Name, Description, Domain Settings and Management Parameters fields as required.

13.Click Advanced Settings to open the Advanced Identity Settings dialog.

5-78 User's Guide

Figure 135. Create new identity advanced setting dialog - example 1

14.Complete the Advanced Identity Settings dialog fields as required and click OK to return to the Create new identity dialog.

15.Click OK. The new identity appears in the Identities List dialog.

16.Select the required identity from the list of available identities and click OK to return to the

Scheme Management dialog. The selected identity is now displayed in the Domain

Identities field.

17.Double-click the EFI LUNs field. The Select EFI LUN dialog opens, allowing you to choose the required EFI Boot LUN from the list of available LUNs.

Figure 136. Select EFI LUN dialog - example 1

18.Select the required EFI Boot LUN from the list of available LUNs and click OK to return to the Scheme Management dialog. The selected LUN is now displayed in the EFI LUNs field.

As the selected LUN is a SAN LUN, the Status icon remains red and the No Link icon appears.

19.Double-click the Data LUNs field. The Select Data LUN dialog opens, allowing you to choose the required Data LUNs from the list of available LUNs.

Tips and Features for Administrators 5-79

20.Select the required Data LUNs from the list of available LUNs and click Add to move the selected Data LUNs to the Data LUNs selected list.

Figure 137. Select Data LUN dialog - example 1

21.Click OK to return to the Scheme Management dialog. Data LUN set is now displayed in the Data LUNs field.

The Status icon remains red and the No Link icon is displayed. You must now link the selected EFI and Data LUNs to the Fibre Channel Host you want to use to access these

LUNs.

5-80 User's Guide

22.Click Domains -> Link to open the Link LUNs to HBA dialog.

Figure 138. Link LUN to HBA dialog - example 1

23.Select the first LUN in the list and select the Redundant mode.

You are informed that dedicated software is required to enable this mode and you are requested to confirm your choice.

Click OK to confirm.

24.Click Set Primary Link to define the main access path to the SAN. The Select HBA dialog opens, allowing you to select the domain PCI slot you want to use to access the LUN.

Figure 139. Select HBA dialog - example 1

25.Select the required PCI slot and click OK. The primary link is now set.

26.Click Set Secondary Link to define the backup access path to the SAN.

27.Select the required PCI slot and click OK. The secondary link is now set.

Tips and Features for Administrators 5-81

28.Repeat Steps 23 to 27 for each LUN in the list and click OK → Apply to return to the

Scheme Management dialog. The Status icon turns green and the Linked icon appears.

29.Click Save. The domain configuration scheme is now available for domain management.

5-82 User's Guide

Creating a Mono-Domain Scheme Using a Selection of Server

Resources

Notes:

• A domain configuration scheme can include more than one Central Subsystems. If you have more than one Bull NovaScale Server, see Configuring and Managing Extended

Systems, on page 5-125.

• For more information about scheme and identity configuration options, refer to:

- Assessing Configuration Requirements, on page 5-31

- Creating a Domain Configuration Scheme, on page 5-33

- Creating a Domain Identity, on page 5-50

The configuration criteria set out in the following tables is used to illustrate this example:

NovaScale 5085 Partitioned Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Data LUNs (SAN only)

MyOffpeakProdScheme

Mono-domain, Cell 1, MyOffpeakProd

MYSERVER-00

1

1 cell: Cell 1

SAN: FDA1300 LUN1

SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC1

Scheme

All resources unlocked

Domain Identity

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

MyOffpeakProd

Time zone: Paris

Linux

MyOffpeakProdNet

124.124.1.0

http://www.MyOffpeakProdWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/12

Enabled

Disabled

Table 42.

Scheme configuration criteria - example 2 - mono-module server

Tips and Features for Administrators 5-83

NovaScale 5165 Partitioned Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Scheme

MyOffpeakProdScheme

Mono-domain, Cell 1, Boot 0Lun1, MyOffpeakProd

MYSERVER-01

1

1 cell: Cell 1

SAN: FDA1300 LUN1

Data LUNs (SAN only) SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC1

All resources unlocked

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Domain Identity

MyOffpeakProd

Time zone: Paris

Linux

MyOffpeakProdNet

124.124.1.0

http://www.MyOffpeakProdWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/12

Enabled

Disabled

Table 43.

Scheme configuration criteria - example 2 - bi-module server

5-84 User's Guide

NovaScale 5245 Partitioned Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Scheme

MyOffpeakProdScheme

Mono-domain, Cell 1, Boot 0Lun1, MyOffpeakProd

MYSERVER-02

1

1 cell: Cell 1

SAN: FDA1300 LUN1

Data LUNs (SAN only) SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC1

All resources unlocked

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Domain Identity

MyOffpeakProd

Time zone: Paris

Linux

MyOffpeakProdNet

124.124.1.0

http://www.MyOffpeakProdWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/12

Enabled

Disabled

Table 44.

Scheme configuration criteria - example 2 - 3 modules server

Tips and Features for Administrators 5-85

NovaScale 5325 Partitioned Server

Name

Description

Central Subsystem(s)

Number of domains

Domain size

EFI boot LUNs

Scheme

MyOffpeakProdScheme

Mono-domain, Cell 1, Boot 0Lun1, MyOffpeakProd

MYSERVER-03

1

1 cell: Cell 1

SAN: FDA1300 LUN1

Data LUNs (SAN only) SAN: FDA 1300 LUN10, LUN6

Fibre channel hosts (SAN only) Primary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC1

All resources unlocked

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Domain Identity

MyOffpeakProd

Time zone: Paris

Linux

MyOffpeakProdNet

124.124.1.0

http://www.MyOffpeakProdWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/12

Enabled

Disabled

Table 45.

Scheme configuration criteria - example 2 - 4 modules server

5-86 User's Guide

To create a mono-domain scheme using a part of server resources:

1. Check that the required hardware resources are available (at least one IOC and one

QBB are required for each server domain) and that the domain Operating System supports the required hardware resources (CPUs, DIMMs, ...).

2. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Schemes to open the Schemes Management pane.

3. Click New to open the Scheme Creation dialog.

4. Complete the Scheme and Description fields.

Figure 140. Scheme creation dialog - example 2

Tips and Features for Administrators 5-87

5. Click Central Subsystem -> Add to select the Central Subsystem to be used by the domain configuration scheme. The Central Subsystem Configuration dialog opens.

NovaScale 5085 Partitioned Server

NovaScale 5165 Partitioned Server

5-88 User's Guide

NovaScale 5245 Partitioned Server

NovaScale 5325 Partitioned Server

Figure 141. Central Subsystem configuration dialog - example 2

6. In the Central Subsystem list, select the required Central Subsystem.

The graphic representation of the selected Central Subsystem appears in the bottom right part of the window.

Tips and Features for Administrators 5-89

7. To create a mono-domain scheme, in the Number of Partitions dropdown list select

1 hardware partition.

8. To configure the partition in order to use a particular cell, in the Central Subsystem graphic representation select the required cell.

9. Click OK to return to the Scheme Management dialog.

The Status icon is red because a Domain Identity and an EFI LUN are required to complete domain configuration.

NovaScale 5085 Partitioned Server

NovaScale 5165 Partitioned Server

5-90 User's Guide

NovaScale 5245 Partitioned Server

NovaScale 5325 Partitioned Server

Figure 142. Scheme Management dialog - example 2

10.In the partition list, double-click the empty cell of the P1 line and the Domain Identities column.

The Identity List dialog opens.

Tips and Features for Administrators 5-91

Figure 143. Identity list dialog - example 2

11.If the required identity is in the list, go to Step 16.

If you want to create a new identity for this domain, click New to open the Create New

Identity dialog. See Creating a Domain Identity, on page 5-50 for details.

Figure 144. Create new identity advanced setting dialog - example 2

12.Complete the Name, Description, Domain Settings and Management Parameters fields as required.

13.Click Advanced Settings to open the Advanced Identity Settings dialog.

5-92 User's Guide

Figure 145. Create new identity advanced setting dialog - example 2

14.Complete the Advanced Identity Settings dialog fields as required and click OK to return to the Create new identity dialog.

15.Click OK. The new identity appears in the Identities List dialog.

16.Select the required identity from the list of available identities and click OK to return to the

Scheme Management dialog. The selected identity is now displayed in the Domain

Identities field.

17.Double-click the EFI LUNs field. The Select EFI LUN dialog opens, allowing you to choose the required EFI Boot LUN from the list of available LUNs.

Figure 146. Select EFI LUN dialog - example 2

18.Select the required EFI Boot LUN from the list of available LUNs and click OK to return to the Scheme Management dialog. The selected LUN is now displayed in the EFI LUNs field.

As the selected LUN is a SAN LUN, the Status icon remains red and the No Link icon appears.

19.Double-click the Data LUNs field. The Select Data LUN dialog opens, allowing you to choose the required Data LUNs from the list of available LUNs.

Tips and Features for Administrators 5-93

20.Select the required Data LUNs from the list of available LUNs and click Add to move the selected Data LUNs to the Data LUNs selected list.

Figure 147. Select Data LUN dialog - example 2

21.Click OK to return to the Scheme Management dialog. Data LUN set is now displayed in the Data LUNs field.

The Status icon remains red and the No Link icon is displayed. You must now link the selected EFI and Data LUNs to the Fibre Channel Host you want to use to access these

LUNs.

5-94 User's Guide

22.Click Domains -> Link to open the Link LUNs to HBA dialog.

Figure 148. Link LUN to HBA dialog - example 2

23.Select the first LUN in the list and click Set Primary Link to define the main access path to the SAN. The Select HBA dialog opens, allowing you to select the domain PCI slot you want to use to access the LUN.

Figure 149. Select HBA dialog - example 2

24.Select the required PCI slot and click OK. The primary link is now set.

25.Repeat Steps 23 to 24 for each LUN in the list and click OK → Apply to return to the

Scheme Management dialog. The Status icon turns green and the Linked icon appears.

26.Click Save. The domain configuration scheme is now available for domain management.

Tips and Features for Administrators 5-95

Creating a Multi-Domain Scheme Using All Server Resources

Notes:

• A domain configuration scheme can include more than one Central Subsystems. If you have more than one Bull NovaScale Server, see Configuring and Managing Extended

Systems, on page 5-125.

• For more information about scheme and identity configuration options, refer to:

- Assessing Configuration Requirements, on page 5-31

- Creating a Domain Configuration Scheme, on page 5-33

- Creating a Domain Identity, on page 5-50

The configuration criteria set out in the following tables is used to illustrate this example:

5-96 User's Guide

NovaScale 5085 Partitioned Server

Name

Scheme

MyProd_PayrollScheme

Description

Central Subsystem(s)

Number of domains

Domain size

Multi-domain, Cells 0 & 1, MyProduction & MyPayroll

MYSERVER-00

2

1 cell per domain:

Cell 0 for MyProduction (Domain 1)

Cell 1 for MyPayroll (Domain 2)

EFI boot LUNs

Data LUNs (SAN only)

SAN: FDA 1300 LUN1 for MyProduction

Local: 0Lun1 for MyPayroll

SAN: FDA 1300 LUN10, LUN6 for MyProduction

SAN: FDA 1300 LUN4 for MyPayroll

Fibre channel hosts (SAN only) MyProduction:

Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

MyPayroll:

Primary Link:Cell_1: Module_0/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC0 for MyProduction

0IOC1 for MyPayroll

All resources unlocked

Domain Identity 1

MyProduction Name

Description

Operating System

Domain network name

Domain IP address

Time zone: Vladivostok

Windows

MyProductionNet

121.121.12.1

Domain URL

Domain CPU parameters

Substitute mode http://www.MyProductionWeb.com

Monothreading mode

High memory IO space Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/13

Enabled

Halt on machine check reset Disabled

Domain Identity 2

MyPayroll Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Time zone: Paris

Linux

MyPayrollNet

122.122.1.0

http://www.MyPayrollWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/14

Substitute mode Enabled

Halt on machine check reset Disabled

Table 46.

Scheme configuration criteria - example 3 - mono-module server

Tips and Features for Administrators 5-97

5-98

NovaScale 5165 Partitioned Server

Name

Scheme

MyProd_PayrollScheme

Description Multi-domain, Cells 0, 1, 2 & 3, MyProduction & MyPayroll

MYSERVER-01 Central Subsystem(s)

Number of domains

EFI boot LUNs

Data LUNs (SAN only)

2

SAN: FDA 1300 LUN1 for MyProduction

Local: 0Lun3 for MyPayroll

SAN: FDA 1300 LUN10, LUN6 for MyProduction

SAN: FDA 1300 LUN4 for MyPayroll

Fibre channel hosts (SAN only) MyProduction:

Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

MyPayroll:

Primary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

IO resource location 0IOC0 mandatory, 0IOC1 & 1IOC0 optional, for MyProduction

1IOC1 mandatory for MyPayrolll

Resource access All resources unlocked

Name

Domain Identity 1

MyProduction

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Time zone: Vladivostok

Windows

MyProductionNet

121.121.12.1

http://www.MyProductionWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

XAN-S11-99999/13

Enabled

Halt on machine check reset

Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Domain Identity 2

MyPayroll

Time zone: Paris

Linux

MyPayrollNet

122.122.1.0

http://www.MyPayrollWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

Disabled

XAN-S11-99999/14

Enabled

Disabled

Table 47.

Scheme configuration criteria - example 3 - bi-module server

User's Guide

NovaScale 5245 Partitioned Server

Name

Description

Central Subsystem(s)

Number of domains

Scheme

MyProd_PayrollScheme

Multi-domain, Cells 0 to 5, MyProduction & MyPayroll

MYSERVER-02

2

EFI boot LUNs

Data LUNs (SAN only)

SAN: FDA 1300 LUN1 for MyProduction

Local: 0Lun3 for MyPayroll

SAN: FDA 1300 LUN10, LUN6 for MyProduction

SAN: FDA 1300 LUN4 for MyPayroll

Fibre channel hosts (SAN only) MyProduction:

Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

MyPayroll:

Primary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC0 mandatory, 0IOC1 & 1IOC0 optional, for MyProduction

1IOC1 mandatory for MyPayrolll

All resources unlocked

Name

Domain Identity 1

MyProduction

Description

Operating System

Domain network name

Domain IP address

Time zone: Vladivostok

Windows

MyProductionNet

121.121.12.1

Domain URL

Domain CPU parameters

Substitute mode

Halt on machine check reset http://www.MyProductionWeb.com

Monothreading mode

High memory IO space Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/13

Enabled

Name

Description

Disabled

Domain Identity 2

MyPayroll

Time zone: Paris

Operating System

Domain network name

Linux

MyPayrollNet

Domain IP address

Domain URL

122.122.1.0

http://www.MyPayrollWeb.com

Domain CPU parameters

High memory IO space

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/14

Enabled

Disabled

Table 48.

Scheme configuration criteria - example 3 - 3 modules server

Tips and Features for Administrators 5-99

NovaScale 5325 Partitioned Server

Name

Description

Central Subsystem(s)

Number of domains

Scheme

MyProd_PayrollScheme

Multi-domain, Cells 0 to 7, MyProduction & MyPayroll

MYSERVER-03

2

EFI boot LUNs

Data LUNs (SAN only)

SAN: FDA 1300 LUN1 for MyProduction

Local: 0Lun3 for MyPayroll

SAN: FDA 1300 LUN10, LUN6 for MyProduction

SAN: FDA 1300 LUN4 for MyPayroll

Fibre channel hosts (SAN only) MyProduction:

Primary Link: Cell_0: Module_0/IOC_0/PCISLOT_1

MyPayroll:

Primary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

IO resource location

Resource access

0IOC0 mandatory, 0IOC1 & 1IOC0 optional, for MyProduction

1IOC1 mandatory for MyPayrolll

All resources unlocked

Name

Domain Identity 1

MyProduction

Description

Operating System

Domain network name

Domain IP address

Time zone: Vladivostok

Windows

MyProductionNet

121.121.12.1

Domain URL

Domain CPU parameters

Substitute mode

Halt on machine check reset http://www.MyProductionWeb.com

Monothreading mode

High memory IO space Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/13

Enabled

Name

Description

Disabled

Domain Identity 2

MyPayroll

Time zone: Paris

Operating System

Domain network name

Linux

MyPayrollNet

Domain IP address

Domain URL

122.122.1.0

http://www.MyPayrollWeb.com

Domain CPU parameters

High memory IO space

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/14

Enabled

Disabled

Table 49.

Scheme configuration criteria - example 3 - 4 modules server

5-100 User's Guide

To create a multi-domain scheme using all server resources:

1. Check that the required hardware resources are available (at least one IOC and one

QBB are required for each server domain) and that the domain Operating System supports the required hardware resources (CPUs, DIMMs, ...).

2. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Schemes to open the Schemes Management pane.

3. Click New to open the Scheme Creation dialog.

4. Complete the Scheme and Description fields.

Figure 150. Scheme creation dialog - example 3

Tips and Features for Administrators 5-101

5. Click Central Subsystem -> Add to select the Central Subsystem to be used by the domain configuration scheme. The Central Subsystem Configuration dialog opens.

NovaScale 5085 Partitioned Server

NovaScale 5165 Partitioned Server

5-102 User's Guide

NovaScale 5245 Partitioned Server

NovaScale 5325 Partitioned Server

Figure 151. Central Subsystem configuration dialog - example 3

6. In the Central Subsystem list, select the required Central Subsystem.

The graphic representation of the selected Central Subsystem appears in the bottom right part of the window.

Tips and Features for Administrators 5-103

7. To create a 2 domains scheme, in the Number of Partitions dropdown list select 2 hardware partitions.

8. Configure the 2 partitions by proceeding as follows: a. Select Partition 1 and select the cells required for domain 1 b. Select Partition 2 and select the cells required for domain 2

9. Click OK to return to the Scheme Management dialog.

The Status icons are red because Domain Identities and EFI LUNs are required to complete domain configuration.

NovaScale 5085 Partitioned Server

5-104 User's Guide

NovaScale 5165 Partitioned Server

NovaScale 5245 Partitioned Server

Tips and Features for Administrators 5-105

NovaScale 5325 Partitioned Server

Figure 152. Scheme Management dialog - example 3

10.In the partition list, double-click the empty cell of the P1 line and the Domain Identities column.

The Identity List dialog opens.

Figure 153. Identities list dialog - example 3

11.If the required identity is in the list, go to Step 16.

To create a new identity for this domain, click New to open the Create New Identity

dialog. See Creating a Domain Identity, on page 5-50 for details.

5-106 User's Guide

Figure 154. Create new identity dialog - example 3

12.Complete the Name, Description, Domain Settings and Management Parameters fields as required.

13.Click Advanced Settings to open the Advanced Identity Settings dialog.

Figure 155. Create new identity advanced setting dialog - example 3

14.Complete the Advanced Identity Settings dialog fields as required and click OK to return to the Create new identity dialog.

15.Click OK. The new identity appears in the Identities List dialog.

Tips and Features for Administrators 5-107

16.Select the required identity from the list of available identities and click OK to return to the

Scheme Management dialog. The selected identity is now displayed in the Domain

Identities field.

17.Repeat Steps 10 to 16 for the empty cell of the P2 line and the Domain Identities column.

18.Double-click the D1 EFI LUNs field. The Select EFI LUN dialog opens, allowing you to choose the required EFI Boot LUN from the list of available LUNs.

Figure 156. Select SAN EFI LUN dialog - example 3

19.Select the required EFI Boot LUN from the list of available SAN LUNs and click OK to return to the Scheme Management dialog. The selected LUN is now displayed in the EFI

LUNs field.

As the selected EFI LUN is a SAN LUN, the Status icon remains red and the No Link icon

appears.

20.Double-click the D2 EFI LUNs field. The Select EFI LUN dialog opens, allowing you to choose the required EFI Boot LUN from the list of available Local LUNs.

Figure 157. Select Local EFI LUN dialog - example 3

As the selected EFI LUN is a Local LUN, the Status icon turns green.

21.Double-click the D1 Data LUNs field. The Select Data LUN dialog opens, allowing you to choose the required Data LUNs from the list of available LUNs.

5-108 User's Guide

22.Select the required Data LUNs from the list of available LUNs and click Add to move the selected Data LUNs to the Data LUNs selected list.

Figure 158. Select Data LUN dialog - example 2

23.Click OK to return to the Scheme Management dialog. Data LUN set is now displayed in the Data LUNs field.

The Status icon remains red and the No Link icon is displayed. You must now link the selected EFI and Data LUNs to the Fibre Channel Host you want to use to access these

LUNs.

24.Repeat Steps 21 to 23 for D2 Data LUNs.

As the selected Data LUN is a SAN LUN, the Status icon turns red and the No Link icon

is displayed. You must now link the selected Data LUN to the Fibre Channel Host you want to use to access this LUN.

Tips and Features for Administrators 5-109

25.Double-click the D1 No Link icon to open the Link LUNs to HBA dialog.

Figure 159. Link LUN to HBA dialog - example 3

26.Select the first LUN in the list and click Set Primary Link to define the main access path to the SAN. The Select HBA dialog opens, allowing you to select the domain PCI slot you want to use to access the LUN.

Figure 160. Select HBA dialog - example 3

27.Select the required PCI slot and click OK. The primary link is now set.

28.Repeat Steps 23 to 27 for each LUN in the list and click OK → Apply to return to the

Scheme Management dialog. The D1 Status icon turns green and the Linked icon appears.

29.Repeat Steps 25 to 27 for D2. All Status icons are green.

30.Click Save. The domain configuration scheme is now available for domain management.

5-110 User's Guide

Creating a Multi-Domain Scheme Using a Selection of Server

Resources

Notes:

• A domain configuration scheme can include more than one Central Subsystems. If you have more than one Bull NovaScale Server, see Configuring and Managing Extended

Systems, on page 5-125.

• For more information about scheme and identity configuration options, refer to:

- Assessing Configuration Requirements, on page 5-31

- Creating a Domain Configuration Scheme, on page 5-33

- Creating a Domain Identity, on page 5-50

The configuration criteria set out in the following tables is used to illustrate this example:

Tips and Features for Administrators 5-111

5-112

NovaScale 5165 Partitioned Server

Name

Scheme

MyTest_DevptScheme

Description

Central Subsystem(s)

Number of domains

Domain size

Multi-domain, Cells 1, 2 & 3, MyTest & MyDevpt

MYSERVER-01

2

Cell 1 for MyTest (Domain 1)

Cells 2 & 3 for MyDevpt (Domain 2)

EFI boot LUNs SAN: FDA 1300 LUN1 for MyTest

Local: 0Lun3 for MyDevpt

Data LUNs (SAN only) SAN: FDA 1300 LUN10, LUN6 for MyTest

SAN: FDA 1300 LUN4 for MyDevpt

Fibre channel hosts (SAN only) MyTest:

Primary Link: Cell_1: Module_0/IOC_0/PCISLOT_1

MyDevpt

Primary Link: Cell_3: Module_1/IOC_1/PCISLOT_1

Secondary Link: Cell_2: Module_1/IOC_0/PCISLOT_1

IO resource location 1IOC0 for MyTest

3IOC1 for MyDevpt

Resource access Cell1, Hublink 1 / Cell2, Cell3, Hublinks 2 & 3

Domain Identity 1

MyTest Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Time zone: Paris

Linux

MyTestNet

126.126.1.2

http://www.MyTestNetWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/15

Enabled

Name

Description

Disabled

Domain Identity 2

MyDevpt

Time zone: Paris

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Windows

MyDevptNet

126.126.1.0

http://www.MyDevptWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

XAN-S11-99999/16

Enabled

Halt on machine check reset Disabled

Table 50.

Scheme configuration criteria - example 4 - bi-module server

User's Guide

NovaScale 5245 Partitioned Server

Name

Scheme

MyTest_DevptScheme

Description

Central Subsystem(s)

Multi-domain, Cells 0, 1, 2 & 4, MyTest & MyDevpt

MYSERVER-02

Number of domains

Domain size

2

Cells 0, 1 & 2 for MyTest (Domain 1)

Cell 4 for MyDevpt (Domain 2)

EFI boot LUNs

Data LUNs (SAN only)

SAN: FDA 1300 LUN1 for MyTest

Local: 0Lun3 for MyDevpt

SAN: FDA 1300 LUN10, LUN6 for MyTest

SAN: FDA 1300 LUN4 for MyDevpt

Fibre channel hosts (SAN only) MyTest:

Primary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

Secondary Link: Cell_2: Module_1/IOC_0/PCISLOT_1

MyDevpt:

Primary Link: Cell_4: Module_2/IOC_1/PCISLOT_1

IO resource location

Resource access

Name

Description

0IOC0 for MyTest

4IOC0 for MyDevpt

Cell0, Cell1, Cell2, Hublinks 0, 1 & 2 / Cell4, Hublink 4

Domain Identity 1

MyTest

Time zone: Paris

Operating System

Domain network name

Linux

MyTestNet

Domain IP address

Domain URL

126.126.1.2

http://www.MyTestWeb.com

Domain CPU parameters

High memory IO space

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/15

Enabled

Disabled

Domain Identity 2

MyDevpt Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

Time zone: Paris

Windows

MyDevptNet

126.126.1.0

http://www.MyDevptWeb.com

Monothreading mode

High memory IO space Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

XAN-S11-99999/16

Enabled

Halt on machine check reset Disabled

Table 51.

Scheme configuration criteria - example 4 - 3 modules server

Tips and Features for Administrators 5-113

5-114

NovaScale 5325 Partitioned Server

Name

Scheme

MyTest_DevptScheme

Description

Central Subsystem(s)

Number of domains

Domain size

Multi-domain, Cells 0 to 6, MyTest & MyDevpt

MYSERVER-03

2

Cells 0, 1, 2 & 3 for MyTest (Domain 1)

Cells 4, 5 & 6 for MyDevpt (Domain 2)

EFI boot LUNs SAN: FDA 1300 LUN1 for MyTest

Local: 0Lun3 for MyDevpt

Data LUNs (SAN only) SAN: FDA 1300 LUN10, LUN6 for MyTest

SAN: FDA 1300 LUN4 for MyDevpt

Fibre channel hosts (SAN only) MyTest:

Primary Link: Cell_1: Module_0/IOC_1/PCISLOT_1

Secondary Link: Cell_2: Module_1/IOC_0/PCISLOT_1

MyDevpt:

Primary Link: Cell_4: Module_2/IOC_1/PCISLOT_1

Secondary Link: Cell_5: Module_2/IOC_0/PCISLOT_1

IO resource location

Resource access

0IOC0 for MyTest

4IOC0 for MyDevpt

Cell0, Cell1, Cell2, Cell 3, Hublinks 0, 1, 2 & 3 /

Cell4, Cell5, Cell6, Hublinks 4, 5 & 6

Domain Identity 1

MyTest Name

Description

Operating System

Domain network name

Domain IP address

Domain URL

Domain CPU parameters

High memory IO space

Time zone: Paris

Linux

MyTestNet

126.126.1.2

http://www.MyTestWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number

Substitute mode

Halt on machine check reset

XAN-S11-99999/15

Enabled

Disabled

Name

Description

Operating System

Domain network name

Domain IP address

Domain Identity 2

MyDevpt

Time zone: Paris

Windows

MyDevptNet

126.126.1.0

Domain URL

Domain CPU parameters

High memory IO space http://www.MyDevptWeb.com

Monothreading mode

Disabled

IO memory space optimization Disabled

Licensing number XAN-S11-99999/16

Substitute mode

Halt on machine check reset

Enabled

Disabled

Table 52.

Scheme configuration criteria - example 4 - 4 modules server

User's Guide

To create a multi-domain scheme using a part of server resources:

1. Check that the required hardware resources are available (at least one IOC and one

QBB are required for each server domain) and that the domain Operating System supports the required hardware resources (CPUs, DIMMs, ...).

2. From the Customer Administrator PAM tree, click Configuration Tasks → Domains →

Schemes to open the Schemes Management pane.

3. Click New to open the Scheme Creation dialog.

4. Complete the Scheme and Description fields.

Figure 161. Scheme creation dialog - example 4

Tips and Features for Administrators 5-115

5. Click Central Subsystem -> Add to select the Central Subsystem to be used by the domain configuration scheme. The Central Subsystem Configuration dialog opens.

NovaScale 5165 Partitioned Server

NovaScale 5245 Partitioned Server

5-116 User's Guide

NovaScale 5325 Partitioned Server

Figure 162. Central Subsystem configuration dialog - example 4

6. In the Central Subsystem list, select the required Central Subsystem.

The graphic representation of the selected Central Subsystem appears in the bottom right part of the window.

7. To create a 2 domains scheme, in the Number of Partitions dropdown list select

2 hardware partitions.

8. Configure the 2 partitions by proceeding as follows: a. Select Partition 1 and select the cells required for domain 1 b. Select Partition 2 and select the cells required for domain 2

9. Click OK to return to the Scheme Management dialog.

The Status icons are red because Domain Identities and EFI LUNs are required to complete domain configuration.

Tips and Features for Administrators 5-117

NovaScale 5165 Partitioned Server

NovaScale 5245 Partitioned Server

5-118 User's Guide

NovaScale 5325 Partitioned Server

Figure 163. Scheme Management dialog - example 4

Tips and Features for Administrators 5-119

10.Double-click the empty D1 Identities field. The Identities List dialog opens.

The Identity List dialog opens.

Figure 164. Identities list dialog - example 4

11.If the required identity is in the list, go to Step 16.

If you want to create a new identity for this domain, click New to open the Create New

Identity dialog. See Creating a Domain Identity, on page 5-50 for details.

Figure 165. Create new identity dialog - example4

12.Complete the Name, Description, Domain Settings and Management Parameters fields as required.

13.Click Advanced Settings to open the Advanced Identity Settings dialog.

5-120 User's Guide

Figure 166. Create new identity advanced setting dialog - example 4

14.Complete the Advanced Identity Settings dialog fields as required and click OK to return to the Create new identity dialog.

15.Click OK. The new identity appears in the Identities List dialog.

16.Select the required identity from the list of available identities and click OK to return to the

Scheme Management dialog. The selected identity is now displayed in the Domain

Identities field.

17.Repeat Steps 10 to 16 for the empty cell of the P2 line and the Domain Identities column.

18.Double-click the D1 EFI LUNs field. The Select EFI LUN dialog opens, allowing you to choose the required EFI Boot LUN from the list of available LUNs.

Figure 167. Select EFI LUN dialog - example 4

19.Select the required EFI Boot LUN from the list of available LUNs and click OK to return to the Scheme Management dialog. The selected LUN is now displayed in the EFI LUNs field.

As the selected EFI LUN is a SAN LUN, the Status icon remains red and the No Link icon

appears.

Tips and Features for Administrators 5-121

20.Double-click the D2 EFI LUNs field. The Select EFI LUN dialog opens, allowing you to choose the required EFI Boot LUN from the list of available LUNs.

As the selected EFI LUN is a Local LUN, the Status icon turns green.

21.Double-click the D1 Data LUNs field. The Select Data LUN dialog opens, allowing you to choose the required Data LUNs from the list of available LUNs.

22.Select the required Data LUNs from the list of available LUNs and click Add to move the selected Data LUNs to the Data LUNs selected list.

Figure 168. Select Data LUN dialog - example 4

23.Click OK to return to the Scheme Management dialog. Data LUN set is now displayed in the Data LUNs field.

The Status icon remains red and the No Link icon is displayed. You must now link the selected EFI and Data LUNs to the Fibre Channel Host you want to use to access these

LUNs.

24.Repeat Steps 21 to 23 for D2 Data LUNs.

As the selected Data LUN is a SAN LUN, the Status icon turns red and the No Link icon

is displayed. You must now link the selected Data LUN to the Fibre Channel Host you want to use to access these LUN.

5-122 User's Guide

25.Double-click the D1 No Link icon to open the Link LUNs to HBA dialog.

Figure 169. Link LUN to HBA dialog - example 2

26.Select the first LUN in the list and click Set Primary Link to define the main access path to the SAN. The Select HBA dialog opens, allowing you to select the domain PCI slot you want to use to access the LUN.

Figure 170. Select HBA dialog - example 4

27.Select the required PCI slot and click OK. The primary link is now set.

28.Repeat Steps 26 to 27 for each LUN in the list and click OK → Apply to return to the

Scheme Management dialog. The D1 Status icon turns green and the Linked icon appears.

29.Repeat Steps 25 to 28 for D2. All Status icons are green.

Tips and Features for Administrators 5-123

30.Select D2 and click Lock Hardware to open the Lock Domain Hardware Resources dialog.

Figure 171. Lock domain hardware resources - example 4

31.Select the resources you want to lock and click OK to return to the Scheme Management

dialog. See Limiting Access to Hardware Resources, on page 5-66 for details.

32.Click Save. The domain configuration scheme is now available for domain management.

Note:

Cell 0 is free and available for use by another scheme, if required.

5-124 User's Guide

Configuring and Managing Extended Systems

A single PAP unit can administer, monitor, and manage several Central Subsystems.

The PAM Domain Configuration Scheme Wizard allows easy configuration of extended systems.

Please contact your BULL Customer Sales Representative for details.

Tips and Features for Administrators 5-125

Scheme, Domain Identity, and Resources Checklists

Name

Scheme Checklist

What name do I want to use for my Scheme?

Description

How can I describe my Scheme to reflect its scope?

Central Subsystem(s)

Number of Domains

Domain Size

EFI Boot LUNs

Which Central Subsystem(s) do I want to use?

How many domains do I need?

How many cells do I want to assign to each domain?

Which EFI boot LUN do I want to use for each domain?

Data LUNs *

Which data LUNs do I want to assign to each domain?

Fibre Channel Hosts *

Which fibre channel host(s) do I want to use to access

LUNs?

I/O Resource Location

Which cells host the I/O resources I want to use?

Resource Access

Do I want to limit access to certain hardware resources?

* Reserved for systems connected to a Storage Area Network (SAN).

Table 53.

Scheme configuration checklist

5-126 User's Guide

Name

Description

Domain Identity Checklist

What name do I want to use for my Domain Identity to reflect the tasks/jobs it will run?

How can I describe my Domain Identity to reflect its use?

Operating System

Which OS do I want to run on this domain? Will this OS support assigned hardware (CPUs, DIMMs)?

Domain Network Name

Which network name will be used to identify this domain?

Domain IP Address

Which IP address will be used to reach this domain?

Domain URL

Which URL can be used to reach my domain Web site (if any)?

Multithreading Mode

Do the CPUs used by this domain support the multithreading mode?

Do I want to enable the multithreading mode for this domain?

High Memory IO Space

Do I need more than 4GB PCI gap space for the PCI boards used by this domain?

Licensing Number

Do I intend to install an application protected by a system serial number on this domain?

Do I want to substitute the physical system serial number with the logical licensing number for optimum flexibility?

Force Halt on Machine

Check Reset

Has my Customer Service Engineer requested me to check this box to troubleshoot my server?

Table 54.

Domain Identity configuration checklist

Tips and Features for Administrators 5-127

Resources Checklist

Central Subsystem:

Cell 0 Cell 1

IO Box

EFI Boot Lun

OS instance

IOC0

0Lu0

IO Box

EFI Boot Lun

OS instance

IOC1

0Lu1

IOC0_Slot 1

I/O Resources I/O Resources

XXXXXXXXXXXXXXXXXX IOC1_Slot 1 XXXXXXXXXXXXXXXXXX

IOC0_Slot 2 IOC1_Slot 2

IOC0_Slot 3 IOC1_Slot 3

IOC0_Slot 4

IOC0_Slot 5

IOC0_Slot 6

IOC1_Slot 4

IOC1_Slot 5

IOC1_Slot 6

Table 55.

Resources checklist - part 1

5-128 User's Guide

Resources Checklist

Cell 2 Cell 3

IO Box

EFI Boot Lun

OS instance

IOC0

1Lu0

IO Box

EFI Boot Lun

OS instance

IOC1

1Lu1

IOC0_Slot 1

I/O Resources I/O Resources

XXXXXXXXXXXXXXXXXX IOC1_Slot 1 XXXXXXXXXXXXXXXXXX

IOC0_Slot 2 IOC1_Slot 2

IOC0_Slot 3

IOC0_Slot 4

IOC0_Slot 5

IOC0_Slot 6

IOC1_Slot 3

IOC1_Slot 4

IOC1_Slot 5

IOC1_Slot 6

Table 56.

Resources checklist - part 2

Tips and Features for Administrators 5-129

Resources Checklist

Cell 4 Cell 5

IO Box

EFI Boot Lun

OS instance

IOC0

1Lu0

IO Box

EFI Boot Lun

OS instance

IOC1

1Lu1

IOC0_Slot 1

I/O Resources I/O Resources

XXXXXXXXXXXXXXXXXX IOC1_Slot 1 XXXXXXXXXXXXXXXXXX

IOC0_Slot 2 IOC1_Slot 2

IOC0_Slot 3

IOC0_Slot 4

IOC0_Slot 5

IOC0_Slot 6

IOC1_Slot 3

IOC1_Slot 4

IOC1_Slot 5

IOC1_Slot 6

Table 57.

Resources checklist - part 3

5-130 User's Guide

Resources Checklist

Cell 6 Cell 7

IO Box

EFI Boot Lun

OS instance

IOC0

1Lu0

IO Box

EFI Boot Lun

OS instance

IOC1

1Lu1

IOC0_Slot 1

I/O Resources I/O Resources

XXXXXXXXXXXXXXXXXX IOC1_Slot 1 XXXXXXXXXXXXXXXXXX

IOC0_Slot 2 IOC1_Slot 2

IOC0_Slot 3

IOC0_Slot 4

IOC0_Slot 5

IOC0_Slot 6

IOC1_Slot 3

IOC1_Slot 4

IOC1_Slot 5

IOC1_Slot 6

Table 58.

Resources checklist - part 4

Tips and Features for Administrators 5-131

Section V - Creating Event Subscriptions and User Histories

This section explains how to:

Customize the PAM Event Messaging System, on page 5-133

Set up Event Subscriptions, on page 5-134

Create, Edit, Delete an E-mail Server, on page 5-136

Create, Edit, Delete an E-mail Account, on page 5-138

Create, Edit, Delete a User History, on page 5-156

Enable / Disable Event Channels, on page 5-140

Create, Edit, Delete an Event Subscription, on page 5-141

Understand Event Message Filtering Criteria, on page 5-143

Preselect, Create, Edit, Delete an Event Filter, on page 5-153

5-132 User's Guide

Customizing the PAM Event Messaging System

During operation, all Central Subsystem activity messages are automatically logged in predefined System Histories that can be viewed and archived by members of the Customer

Administrator group. In addition, PAM software reports and logs environmental, command, and hardware errors.

A comprehensive set of Event Message subscriptions allows connected and non-connected users to be notified of system status and activity.

The PAM event messaging system is based on a subscription mechanism allowing the

Customer Administrator to send precisely filtered event messages to targeted individuals and/or groups via four channels (WEB Interface, E-mail, User History, SNMP) as shown in

Figure 172.

Figure 172. PAM event messaging system features

Note:

PAM software is delivered with a set of predefined subscriptions that have been designed to suit the needs of most Administrators and Operators. If required, you can use PAM

Configuration tools to set up customized subscriptions.

From the PAM tree, expand the Configuration Tasks and Events nodes to display event configuration options.

Tips and Features for Administrators 5-133

Setting up Event Subscriptions

Before creating an event subscription, you should establish:

• the set of messages you want a user or a group of users to receive (Filter),

• how you want the user or group of users to receive messages (Channel).

Selecting a Filter

The comprehensive event message filtering system allows you to use a predefined filter or to create a specific filter, according to your needs.

See Preselecting an Event Filter, on page 5-153 and Creating an Event Filter, on page

5-154.

Selecting a Channel

Four channels can be used to forward event messages, according to targeted recipients:

Channel

E-mail

Advantage

Allows a specific user to receive system notifications/ alerts.

User history Records specific system operations/alerts into a dedicated log file.

Web

SNMP

Allows a specific group of users to be warned of system operations/ alerts when connected to the PAM Web interface.

Forwards specific messages as SNMP traps to the selected SNMP application.

Table 59.

Event channels

5-134 User's Guide

Event Subscription Flowcharts

Once you have established who the targeted recipients are and which channel you want to use, you can use the following flowcharts as a quick guide to event subscription procedures.

E-mail Event Subscription

Allows a specific user to receive system notifications/alerts via e-mail.

Preselect an Event filter, on page 5-153, or Create an Event Filter, on page 5-154.

Select or Create an E-mail Server, on page 5-136.

Select or Create an E-mail Account, on page 5-138.

Create the Event Subscription, on page 5-141.

User History Event Subscription

Records specific system operations/alerts into a dedicated log file.

Preselect an Event filter, on page 5-153, or Create an Event Filter, on page 5-154.

Select or Create a User History, on page 5-157.

Create the Event Subscription, on page 5-141.

Web Event Subscription

Allows a specific group of users to be warned of system operations/alerts

when connected to the PAM Web interface.

Preselect an Event filter, on page 5-153, or Create an Event Filter, on page 5-154.

Create the Event Subscription, on page 5-141.

SNMP Event Subscription

Forwards system operations/alerts as SNMP traps to the selected SNMP Manager.

Preselect an Event filter, on page 5-153, or Create an Event Filter, on page 5-154.

Create the Event Subscription, on page 5-141.

Tips and Features for Administrators 5-135

Creating, Editing, Deleting an E-mail Server

To send messages via the e-mail channel, you must first create an e-mail server. Several e-mail accounts can then be attached to the same e-mail server, see Creating an E-mail

Account, on page 5-138.

Creating an E-mail Server

Important:

Before creating an E-mail server, you must first complete the Site engineer email account field on the Customer Information page. This account will be displayed in the Sender email field,

as shown in the following screen shot. See Modifying Customer Information, on page 5-19.

To create an e-mail server:

1. Click Configuration Tasks → Events → E-mail servers in the PAM tree. The e-mail servers configuration page opens.

Figure 173. E-mail servers configuration page

2. Click New in the toolbar.

3. Enter the server name in the Name field, the address of the existing e-mail server you intend to use in the URL field, and a brief description, if required, in the Description field.

4. Select the required Security level and enter the corresponding username and password

(Basic and Secure levels only).

5. Click OK to confirm the creation of the new e-mail server.

5-136 User's Guide

Editing E-mail Server Attributes

To modify an e-mail server URL / description:

1. Click Configuration Tasks → Events → E-mail servers in the PAM tree. The e-mail server configuration page opens. See Figure 173 above.

2. Select the required server from the e-mail servers list.

3. Click Edit in the toolbar to modify the server URL / description.

4. Enter a new address in the URL field and/or a new description in the Description field, as applicable.

5. Click OK to confirm the modification.

Deleting an E-mail Server

Important:

Before deleting an e-mail server, all the accounts attached to that server must be attached to another server, or deleted.

At least one e-mail server must be defined to send messages via the e-mail channel.

If e-mail accounts are attached to this e-mail server:

see Editing E-mail Account Attributes, on page 5-137 to attach these accounts to another

server, or

see Deleting an E-mail Account, on page 5-139 to delete these accounts.

To delete an e-mail server:

1. Click Configuration Tasks → Events → E-mail Servers in the PAM tree. The e-mail server

configuration page opens. See Figure 173, on page 5-136.

2. Select the required server from the e-mail servers list.

3. Click Delete in the toolbar.

4. Click OK to confirm the deletion of the selected e-mail server.

Tips and Features for Administrators 5-137

Creating, Editing, Deleting an E-mail Account

To send messages via the e-mail channel, you must first create an e-mail server and then attach an e-mail address to this e-mail server. Several e-mail accounts can be attached to the same e-mail server.

Creating an E-mail Account

To create an e-mail account:

1. Click Configuration Tasks → Events → E-mail accounts in the PAM tree. The e-mail accounts configuration page opens.

Figure 174. E-mail accounts configuration page

2. Click New in the toolbar.

3. Enter the new account name in the Account field and corresponding e-mail address in the

URL Address field.

4. Select the server to be used to deliver messages to this address from the E-mail Server list.

If the required e-mail server is not in the list, see Creating an E-mail Server, on page

5-136.

5. Enter a brief description, if required, in the Description field.

6. Click OK to confirm the creation of the new e-mail account.

The new e-mail account can now be selected when you set up an event subscription to be sent via the e-mail channel.

Note:

The OK button is accessible once all mandatory fields have been completed.

5-138 User's Guide

Editing E-mail Account Attributes

To modify an e-mail account name, address, server and/or description:

1. Click Configuration Tasks → Events → E-mail accounts in the PAM tree. The e-mail accounts configuration page opens. See Figure 174 above.

2. Select the required account from the e-mail accounts list.

3. Click Edit in the toolbar to modify the account name, address, server and/or description.

4. Enter the new attributes in the corresponding fields, as applicable. If the required e-mail

server is not in the list, see Creating an E-mail Server, on page 5-136.

5. Click OK to confirm the modification.

Deleting an E-mail Account

Important:

Before deleting an e-mail account, all the event subscriptions attached to that account must be attached to another account, or deleted.

If event subscriptions are attached to this e-mail account, see:

Editing Event Subscription Attributes, on page 5-142 to attach these event subscriptions to

another account,

or Deleting an Event Subscription, on page 5-142 to delete these event subscriptions.

To delete an e-mail account:

1. Click Configuration Tasks → Events → E-mail accounts in the PAM tree. The e-mail accounts configuration page opens. See Figure 174 above.

2. Select the required account from the e-mail accounts list.

3. Click Delete in the toolbar.

4. Click OK to confirm the deletion of the selected e-mail account.

Tips and Features for Administrators 5-139

Enabling / Disabling Event Channels

An event channel must be selected and enabled for all event subscriptions. The following table provides the Customer Administrator with guidelines for selecting an event channel.

EMAIL

SNMP

Channel

LOG (User History)

WEB (PAM Interface)

Target

Specific recipient.

All user groups.

SNMP application.

Selected users.

Enabled

Allows a specific recipient to directly receive specific messages.

Disabled

Allows all users to access specific messages.

Forwards specific messages as SNMP traps to the selected

SNMP application for processing.

Allows a specific group of users to view specific messages.

Advanced feature:

Only to be used if the system generates too many messages and maintenance actions are to be carried out.

Table 60.

Event channel selection guidelines

Note:

When an event channel is disabled, all messages sent via that channel are lost.

All event channels are enabled by default.

To enable / disable an event channel:

1. Click Configuration Tasks → Events → Channels in the PAM tree. The channels configuration page opens.

Figure 175. Event Channels configuration page

2. Select the Yes or No radio button in the Enable column to enable or disable the required channel.

3. Click the Save icon to confirm the new configuration.

5-140 User's Guide

Creating, Editing, Deleting an Event Subscription

Once event subscription prerequisites have been set up, you can create the event subscriptions required to send messages to their destinations. See Event Subscription

Flowcharts, on page 5-135.

Creating an Event Subscription

To create an event subscription:

1. Click Configuration Tasks → Events → Subscriptions in the PAM tree. The event subscription configuration page opens.

2. Click New in the toolbar.

Figure 176. New Event Subscription dialog box

3. Select the Active and Enable checkboxes to activate and enable the new subscription.

4. Enter a short, readily identifiable name in the Name field and a brief description, if required, in the Description field.

5. Select the required channel radio button:

- E-MAIL: to send event messages to an e-mail address.

- LOG: to send event messages to a user history.

- SNMP: to send event messages to the SNMP Manager.

- WEB: to send event messages to the status pane in the PAM web interface.

Tips and Features for Administrators 5-141

6. Select a pre-configured E-mail Account, User History, or User Group from the drop-down menu or enter an SNMP Manager IP address or server name.

7. Select a pre-configured filter from the Filter drop-down menu.

8. Click OK to confirm the creation of the new event subscription.

9. The event subscription configuration page is automatically updated with the new subscription.

10.Click Test Subscription to check that the event subscription has been configured correctly.

Subscription parameters will be used to send a test message.

Note:

The OK button is accessible once all mandatory fields have been completed.

Editing Event Subscription Attributes

To modify an event subscription description, channel, address and/or filter, or to activate / deactivate and/or enable / disable an event subscription:

1. Click Configuration Tasks → Events → Subscriptions in the PAM tree. The event subscription configuration page opens.

2. Select the required event subscription in the event subscription table.

3. Click Edit to modify the attributes of this event subscription. The Edit Event Subscription dialog box opens.

4. Select the new channel, E-mail Account, User History, or User Group from the drop-down menu or enter a new SNMP Manager IP address or server name.

5. Modify the description.

6. If required, activate / deactivate and/or enable / disable the event subscription by selecting / deselecting the Active and Enable checkboxes.

Warning:

If you deactivate / disable an event subscription, no events will be sent to the recipient(s) until the event subscription is reactivated / re-enabled.

7. Click OK to confirm the modification.

8. Click Test Subscription to check that the event subscription has been re-configured correctly.

Note:

The OK button is accessible once all mandatory fields have been completed.

Deleting an Event Subscription

To delete an event subscription:

1. Click Configuration Tasks → Events → Subscriptions in the PAM tree. The event subscription configuration page opens.

2. Select the required event subscription in the event subscription table.

3. Click Delete in the toolbar. The Delete Subscription dialog box opens.

4. Click OK to confirm the deletion of the selected event subscription.

5-142 User's Guide

Understanding Event Message Filtering Criteria

The set of predefined filters supplied with PAM software covers everyday event messaging requirements. However, a comprehensive filtering system allows you to finely tune event messaging criteria, if required.

Before creating a new event filter, you should get to know filtering criteria options.

1. Click Configuration Tasks → Events → Filters in the PAM tree. The filter configuration page opens with the list of existing event message filters.

2. Click New to display the Standard Filter page.

Figure 177. Event message standard filtering criteria chart

Tips and Features for Administrators 5-143

3. Click Advanced to display the Advanced Filter page.

Figure 178. Event message advanced filtering criteria chart

4. Carefully analyze Tables 61 and 62 to understand the various options.

5-144 User's Guide

Standard Event Message Filtering Criteria

Select

Criteria Description

All the checkboxes in this column are selected by default. When an event message S checkbox is deselected, the event message is removed from the filter.

Actions

- Select the S checkbox if you want to include the event message in the new filter.

- Deselect the S checkbox if you do not want to include the event message in the new filter.

Message/Identifier Gives a message description and provides a clickable link to the associated help messages.

Actions

- Toggle the Message/Identifier column by clicking Message or

Identifier in the toolbar.

Acknowledge

- Double click the required message. The corresponding help message opens.

This column is only applicable to messages sent to the PAM Web interface and is interactive with the Duration column (see below). All the checkboxes in this column are selected by default. When the message Ack checkbox is selected, the event message will be displayed in the event list until it is manually acknowledged by a user.

Note:

The PAM Web interface stores up to 150 event messages maximum per user group (100 messages by default). Once this limit has been reached, messages may be deleted in order of arrival, even if they have not been acknowledged.

Actions

- Select the Ack checkbox if you want the event message to be displayed until it is manually acknowledged by a user.

- Deselect the Ack checkbox if you want the event message to be deleted automatically after a specified period of time. The

Duration dialog box opens (see below).

Tips and Features for Administrators 5-145

Criteria

Duration

Description

This column is only applicable to messages sent to the PAM Web interface and is interactive with the Ack column (see above). When the specified duration expires, the event message is deleted automatically.

Note:

The PAM Web interface stores up to 150 event messages maximum per user group (100 by default). Once this limit has been reached, messages may be deleted in order of arrival, even if the set duration has not expired.

Actions

- Double click the Duration cell to open the Message Display

Duration dialog box.

- Select the Display message until acknowledged checkbox if you want to manually acknowledge the message before it is removed from the display and click OK to apply.

- Enter a value in the Duration field and use the drop-down menu to select the duration unit: seconds, minutes, hours, or days.

- The Apply to this message only radio button is selected by default. If required, select another radio button to apply the duration setting to other messages included in the filter.

- Click OK to set the duration. The new duration value is displayed in the Duration cell and the Ack checkbox is deselected (see above).

5-146 User's Guide

Criteria

Severity Level

Description

This column is used to set message severity level(s): Information, Success, Warning, and Error. At least one severity level must be selected to define the filter.

Actions

- Double click the Severity cell to open the dialog box.

- All severity levels are selected by default. Deselect the required checkbox to remove a severity level from the filter.

- Select the Apply to all messages checkbox to apply this severity level to all the messages included in the filter.

- Click OK to set and apply the severity level. The new severity level is displayed in the corresponding Severity cell.

Table 61.

Standard event message filtering criteria

Tips and Features for Administrators 5-147

Advanced Event Message Filtering Criteria

Note:

Advanced filtering criteria are reserved for advanced users and are to be used with care.

Criteria

Thresholding

Description

Thresholding is defined on a Count / Period basis aimed at routing significant messages only. Identical messages are counted and when the number of messages indicated in the Threshold Count field is reached within the period of time indicated in the Threshold Period field, this message is selected for routing.

Actions

- Double click the Threshold cell to open the dialog box.

5-148 User's Guide

- Select the Threshold Inactive radio button to deactivate thresholding.

- Select the Apply to all messages checkbox to deactivate the thresholding setting on all the messages included in the filter.

- Select the Threshold Active radio button to activate thresholding.

- Enter the required number of messages in the Threshold Count field, the required period of time in the Threshold Period field, and use the drop-down menu to select the time unit: seconds, minutes, hours, or days.

- Select the corresponding radio button to apply thresholding settings to one or more messages included in the filter.

Note:

The Apply to this message only radio button is selected by default.

- Click OK to set thresholding. The new Threshold Count and

Threshold Period settings are displayed in the Threshold cell.

Note:

Inactive is displayed in the Threshold cell when thresholding is deactivated.

Criteria

Clipping

Description

Clipping is defined on a Count / Period basis aimed at routing a pre-defined number of messages only. Identical messages are counted and when the number of messages indicated in the Clipping

Count field is reached within the period of time indicated in the Clipping Period field, no other messages will be selected for routing.

Actions

- Double click the Clipping cell to open the dialog box.

- Select the Clipping Inactive radio button to deactivate clipping.

- Select the Apply to all messages checkbox to deactivate the thresholding setting on all the messages included in the filter.

- Select the Clipping Active radio button to activate clipping.

- Enter the required number of messages in the Clipping Count field, the required period of time in the Clipping Period field, and use the drop-down menu to select the time unit: seconds, minutes, hours, or days.

- Select the corresponding radio button to apply clipping settings to one or more messages included in the filter.

Note:

The Apply to this message only radio button is checked by default.

- Click OK to set clipping. The new Clipping Count and Clipping

Period settings are displayed in the Clipping cell.

Note:

Inactive is displayed in the Clipping cell when clipping is deactivated.

Tips and Features for Administrators 5-149

Source

Criteria Description

Each event message refers to a source (the component that generated the message) and a target (the component referred to in the message) (see below). This feature allows messages to be filtered according to one or more Source string(s) and is particularly useful for debugging and troubleshooting.

Actions

- Double click the Source cell to open the dialog box.

- Select a source filter from the Event Sources list.

- If the list is empty, enter a source string in the Source filter field and click Add. The new source filter is displayed in the Event

Sources list. (Example source strings can be viewed in history files).

- Click Remove or Remove All to remove one or more source strings from the Event Sources list.

- Repeat for each source string to be included in the filter.

- Click Apply list to all messages to apply the specified source list to all the messages included in the filter.

- Click OK to apply the source list. Specified is displayed in the

Source cell.

Note:

All is displayed in the Source cell if the source is not specified.

5-150 User's Guide

Target

Criteria Description

Each event message refers to a target (the component referred to in the message) and a source (the component that generated the message) (see above). This feature allows messages to be filtered according to one or more Target string(s) and is particularly useful for debugging and troubleshooting.

Actions

- Double click the Target cell to open the dialog box.

- Select a target filter from the Event Targets list.

- If the list is empty, enter a target string in the Target filter field and click Add. The new target filter is displayed in the Event

Targets list. (Example target strings can be viewed in history files).

- Click Remove or Remove All to remove one or more target strings from the Event Targets list.

- Repeat for each target string to be included in the filter.

- Click Apply list to all messages to apply the specified target list to all the messages included in the filter.

- Click OK to apply the target list. Specified is displayed in the

Target cell.

Note:

All is displayed in the Target cell if the target is not specified.

Tips and Features for Administrators 5-151

Criteria

Keyword

Description

This feature allows messages to be filtered according to a Keyword contained in the messages. Any relevant word(s) contained in source

/ target strings can be used.

Actions

- Double click the Keywords cell to open the dialog box.

- Select a keyword filter from the Event Keywords list.

- If the list is empty, enter a keyword in the Keyword filter field and click Add. The new keyword filter is displayed in the Event

Keywords list. (Example keywords can be viewed in history files).

- Click Remove or Remove All to remove one or more keyword from the Event Keywords list.

- Repeat for each keyword to be included in the filter.

- Click Apply list to all messages to apply the specified keyword list to all the messages included in the filter.

- Click OK to apply the keyword list. Specified is displayed in the

Keyword cell.

Note:

All is displayed in the Keywords cell if the keyword is not specified.

Table 62.

Advanced event message filtering criteria

5-152 User's Guide

Preselecting, Creating, Editing, Deleting an Event Filter

An event filter must be selected for all event subscriptions. The event messaging system is delivered with a set of predefined filters.

Preselecting an Event Filter

Before proceeding to set up an event subscription, you are advised to check which predefined filter is adapted to your needs:

1. Click Configuration Tasks → Events → Filters in the PAM tree. The filter configuration page opens.

Figure 179. Filters configuration page

2. Check that the required filter is present.

You may also define a specific filter by using the comprehensive event message filtering

utility. See Creating an Event Filter, on page 5-154.

Tips and Features for Administrators 5-153

Creating an Event Filter

Once you have established which filtering criteria you want to apply to your new filter, you can proceed to create a new event filter:

1. Click Configuration Tasks → Events → Filters in the PAM tree. The filter configuration page opens with the list of existing event message filters.

2. Click New to display the Create a New Event Filter page. The standard event message filtering criteria table is displayed.

Figure 180. New Filter configuration page - standard event message filtering criteria table

3. Enter a relevant name in the Filter Name field and a brief description, if required, in the

Description field.

Note:

For further details about event filtering criteria and options, see Standard Event

MessageFiltering Criteria, on page 5-145 and Advanced Event Message Filtering

Criteria, on page 5-148.

4. Deselect the S checkbox for the event messages not to be included in the filter.

5. If the filter is to be used to send messages to the PAM Web interface, select the Ack checkbox if you want the event message to be manually acknowledged by a user; or deselect the Ack checkbox to enter a display value in the Duration cell.

6. Double click the Severity cell to select the message severity level.

5-154 User's Guide

7. If required, click Advanced to access advanced filtering criteria. The advanced event message filtering criteria chart is displayed.

Figure 181. New Filter configuration page - advanced event message filtering criteria table

8. When you have finished configuring your event filter, click Create.

9. Repeat steps 3 to 8 for each new event filter you want to create.

10.Click Close to save changes. The new filter appears in the Filters list.

Editing Event Filter Attributes

1. Click Configuration Tasks → Events → Filters in the PAM tree. The filter configuration page opens with the list of existing event message filters. See Figure 180 above.

2. Select the required filter from the event message filter list.

3. Click Edit in the toolbar to modify filter attributes.

4. Click OK to save changes.

Deleting an Event Filter

Important:

Before deleting an event filter, all the event subscriptions using that filter must either be modified to use another filter, or deleted.

1. Click Configuration Tasks → Events → Filters in the PAM tree. The filter configuration page opens with the list of existing event message filters. See Figure 179 above.

2. Select the required filter from the event message filter list.

3. Click Delete in the toolbar.

4. Click OK to confirm the deletion of the selected event filter.

Tips and Features for Administrators 5-155

Creating, Editing, Deleting a User History

There are two types of histories: System histories and User histories.

System histories cannot be modified and are are only accessible to members of the Customer

Administrator group.

User histories can be created, edited and deleted and are accessible to members of both the

Customer Administrator and Customer Operator groups.

For guidance, System history contents are explained in the following table:

System History Contents

History Name

HistoryTrace

InterventionReportHistory

IPMITrace

MaestroHistory

MaestroTrace

PAMHistory

PAMTrace

RPCTrace

SANTrace

Table 63.

System history contents

Contents

History Manager trace file. Logs archiving actions and history/archive processing errors.

Reserved for Support personnel.

Reserved.

Reserved.

Reserved for Support personnel.

Central PAM software history file. Logs all error or information messages concerning PAM software and all operator visible events.

Logs domain power sequence trace data.

Reserved for Support personnel.

Logs SAN-IT trace data.

5-156 User's Guide

Creating a User History

Note:

The Site Data Directory will be used, by default, if you do not specify a different directory

when you create a user history. See Viewing PAM Version Information, on page 4-13

To create a user history:

1. Click Configuration Tasks -> User Histories in the PAM tree. The User Histories control pane opens.

2. Click New in the toolbar. The Create a New User History dialog opens.

Figure 182. Create a New User History dialog

3. Enter a name in the Name field (mandatory) and a brief description, if required, in the

Description field.

4. Enter a directory pathname in the Directory field. If this field is left blank, the default

Histories directory will be used.

Tips and Features for Administrators 5-157

5. Use the drop-down menu to select an automatic archiving policy Type:

Type

Number of Days

Size in KBytes

Automatic Archiving Policy

The system will automatically create an archive for this history after the number of days specified in the Value field.

The system will automatically create an archive when this history reaches the size in KBytes specified in the Value field.

Note:

Size in KBytes must be greater than 10.

Number of Records The system will automatically create an archive when this history reaches the number of records specified in the Value field.

Note:

Number of Records must be greater than 10.

Table 64.

History automatic achiving policies

6. Enter the required number of days / KBytes / records in the Value field, as applicable.

7. Enter a directory pathname in the Directory field. If this field is left blank, the default

Archives directory will be used.

8. If you want the archive to be automatically deleted at regular intervals, select the Delete archive files checkbox and enter the number of days you want to maintain the archive in the days field.

9. Click OK to confirm the creation of the new history. The new history appears in the list of available histories.

Note:

The OK button is accessible once all mandatory fields have been completed.

Editing History Parameters

To modify the archiving parameters of system / user histories:

1. Click Configuration Tasks -> Histories in the PAM tree. The Histories control pane opens.

2. Select the required History from the Histories list.

3. Click Edit in the toolbar to modify the archiving parameters for this History. The Edit

History Parameters page opens.

4. Enter the new parameters in the corresponding fields.

5. Click OK to confirm the modification.

5-158 User's Guide

Deleting a User History

Important:

Before deleting a user history, all the event subscriptions attached to that history must be attached to another history, or deleted. System histories cannot be deleted.

If event subscriptions are attached to this history:

see Editing Event Subscription Attributes, on page 5-142 to attach these event

subscriptions to another history, or

see Deleting an Event Subscription, on page 5-142 to delete these event subscriptions.

To delete a user history:

1. Check that no event subscriptions are attached to this history.

2. Click Configuration Tasks -> Histories in the PAM tree. The Histories control pane opens.

3. Select the required History from the Histories list.

4. Click Delete in the toolbar.

5. Click OK to confirm the deletion of the selected user history.

Tips and Features for Administrators 5-159

5-160 User's Guide

Appendix A. Specifications

NovaScale 5085 Server Specifications, on page A-2

NovaScale 5165 Server Specifications, on page A-4

NovaScale 5245 Server Specifications, on page A-6

NovaScale 5325 Server Specifications, on page A-8

Server Specifications A-1

NovaScale 5085 Server Specifications

NovaScale 5085 Servers are delivered rack-mounted in 40U or 19U cabinets.

The following web site may be consulted for general site preparation information: http://www.cs.bull.net/aise

.

1300H

Height:

Width:

Depth:

Weight (max):

1300L

Height:

Width:

Depth:

Weight (max.):

Cabinet Dimensions / Weight

Unpacked

195.5 cm (77.0 in)

60.0 cm (23.6 in)

129.5 cm (51.0 in)

340 kg (725 lb)

103.5 cm (40.7 in)

60.0 cm (23.6 in)

129.5 cm (51.0 in)

290 kg (618 lb)

1300H

Height:

Width:

Depth:

Weight (max):

1300L

Height:

Width:

Depth:

Weight (max.):

Service Clearance

Packed

200.0 cm (78.7 in)

80.0 cm (31.5 in)

140.0 cm (55.1 in)

370 kg (790 lb)

108.0 cm (42.5in)

80.0 cm (31.5 in)

140.0 cm (55.1 in)

320 kg (682 lb)

Front

Rear

Side (free side)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Pressure / Elevation

150 cm

100 cm

100 cm

Operating Limits

+15

°

C to +30

°

C (+59

°

F to +86

°

F)

Gradient 5

°

C/h (41

°

F/h)

35 to 60% (Gradient 5%/h)

+24

°

C (+75.2

°

F)

0.019 kg water/kg dry air

Sea level < 2500 m

Temperature

Hygrometry

Optimum Operational Reliability

+ 22

°

C (+ 3

°

C) (+ 72

°

F (+ 5

°

F)

50% (+ 5%)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Non-Operating Limits

+5

°

C to +50

°

C (+41

°

F to +122

°

F)

Gradient 25

°

C/h (77

°

F/h)

5 to 95% (Gradient 30%)

+28

°

C (+82.4

°

F)

0.024 kg water/kg dry air

Shipping Limits

Dry bulb temperature range -35

°

C to +65

°

C (-31

°

F to +149

°

F)

Gradient 25

°

C/h (77

°

F/h)

Relative humidity (non-condensing)

5 to 95% Gradient 30%/h

Acoustic Power at Room Temperature +20

°

C (+68

°

F)

Lw(A) 6.3 Bels

System Running

Lw(A) 6.1 Bels

System Idle

A-2 User's Guide

Power Cables

PDU-2-4-M-32A

AC (32A)

Cable type

Connector type

1 per PDU

3 x AWG10 ( 3 x 6 mm

2

/ #10US)

IEC60309-32A

It is mandatory for power lines and terminal boxes to be located within the immediate vicinity of the system and to be easily accessible. Each power line must be connected to a separate, independent electrical panel and bipolar circuit breaker. PDUs require an extra cable length of 1.5 meters for connection inside the cabinet.

Electrical Specifications

(power supplies are auto-sensing and auto-ranging)

Current draw

Power consumption

Thermal dissipation

11 A max. at 200 VAC input

2400 VA per full CSS module

2400 W / 8190 BTU per full CSS module

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

Europe

230 VAC (Phase / Neutral)

207 - 244 VAC

50 Hz 1%

United States of America

208 VAC (Phase / Neutral)

182 - 229 VAC

60 Hz 0.3%

Japan

200 VAC (Phase / Neutral)

188 - 212 VAC

60 Hz 0.2%

Brazil

220 VAC (Phase / Neutral)

212 - 231 VAC

60 Hz 2%

Breaker Protection (Mains Power)

PDU-2-4-M-32A

Maximum inrush current

32A Curve C

210A / per quarter period

Table 65.

NovaScale 5085 Server specifications

Server Specifications A-3

NovaScale 5165 Server Specifications

NovaScale 5165 Servers are delivered rack-mounted in 40U or 19U cabinets.

The following web site may be consulted for general site preparation information: http://www.cs.bull.net/aise

.

1300H

Height:

Width:

Depth:

Weight (max):

1300L

Height:

Width:

Depth:

Weight (max.):

Cabinet Dimensions / Weight

Unpacked

195.5 cm (77.0 in)

60.0 cm (23.6 in)

129.5 cm (51.0 in)

450 kg (959 lb)

103.5 cm (40.7 in)

60.0 cm (23.6 in)

129.5 cm (51.0 in)

400 kg (852 lb)

1300H

Height:

Width:

Depth:

Weight (max):

1300L

Height:

Width:

Depth:

Weight (max.):

Service Clearance

Packed

200.0 cm (78.7 in)

80.0 cm (31.5 in)

140.0 cm (55.1 in)

480 kg (1022 lb)

108.0 cm (42.5in)

80.0 cm (31.5 in)

140.0 cm (55.1 in)

430 kg (915 lb)

Front

Rear

Side (free side)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Pressure / Elevation

Temperature

Hygrometry

150 cm

100 cm

100 cm

Operating Limits

+15

°

C to +30

°

C (+59

°

F to +86

°

F)

Gradient 5

°

C/h (41

°

F/h)

35 to 60% (Gradient 5%/h)

+24

°

C (+75.2

°

F)

0.019 kg water/kg dry air

Sea level < 2500 m

Optimum Operational Reliability

+ 22

°

C (+ 3

°

C) (+ 72

°

F (+ 5

°

F)

50% (+ 5%)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Non-Operating Limits

+5

°

C to +50

°

C (+41

°

F to +122

°

F)

Gradient 25

°

C/h (77

°

F/h)

5 to 95% (Gradient 30%)

+28

°

C (+82.4

°

F)

0.024 kg water/kg dry air

Dry bulb temperature range

Relative humidity (non-condensing)

Shipping Limits

-35

°

C to +65

°

C (-31

°

F to +149

°

F)

Gradient 25

°

C/h (77

°

F/h)

5 to 95% Gradient 30%/h

A-4 User's Guide

Acoustic Power at Room Temperature +20

°

C (+68

°

F)

System Running System Idle

Lw(A) 6.3 Bels Lw(A) 6.1 Bels

Power Cables

AC (32A)

Cable type

Connector type

PDU-2-4-M-32A

1 per PDU

3 x AWG10 (3 x 6 mm 2 / #10US)

IEC60309-32A

It is mandatory for power lines and terminal boxes to be located within the immediate vicinity of the system and to be easily accessible. Each power line must be connected to a separate, independent electrical panel and bipolar circuit breaker.

PDUs require an extra cable length of 1.5 meters for connection inside the cabinet.

Electrical Specifications

(power supplies are auto-sensing and auto-ranging)

Current draw

Power consumption

Thermal dissipation

11 A max. at 200 VAC input

2400 VA per full CSS module

2400 W / 8190 BTU per full CSS module

Europe

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

230 VAC (Phase / Neutral)

207 - 244 VAC

50 Hz 1%

United States of America

208 VAC (Phase / Neutral)

182 - 229 VAC

60 Hz 0.3%

Japan

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

200 VAC (Phase / Neutral)

188 - 212 VAC

60 Hz 0.2%

Brazil

220 VAC (Phase / Neutral)

212 - 231 VAC

60 Hz 2%

Breaker Protection (Mains Power)

PDU-2-4-M-32A

Maximum inrush current

32A Curve C

210A / per quarter period

Table 66.

NovaScale 5165 Server specifications

Server Specifications A-5

NovaScale 5245 Server Specifications

NovaScale 5245 Servers are delivered rack-mounted in 40U cabinets.

The following web site may be consulted for general site preparation information: http://www.cs.bull.net/aise

.

1300H

Height:

Width:

Depth:

Weight (max):

Cabinet Dimensions / Weight

Unpacked

195.5 cm (77.0 in)

60.0 cm (23.6 in)

129.5 cm (51.0 in)

1300H

Height:

Width:

Depth:

560 kg (1193 lb) Weight (max):

Service Clearance

Packed

200.0 cm (78.7 in)

80.0 cm (31.5 in)

140.0 cm (55.1 in)

590 kg (1257 lb)

Front

Rear

Side (free side)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Pressure / Elevation

150 cm

100 cm

100 cm

Operating Limits

+15

°

C to +30

°

C (+59

°

F to +86

°

F)

Gradient 5

°

C/h (41

°

F/h)

35 to 60% (Gradient 5%/h)

+24

°

C (+75.2

°

F)

0.019 kg water/kg dry air

Sea level < 2500 m

Temperature

Hygrometry

Optimum Operational Reliability

+ 22

°

C (+ 3

°

C) (+ 72

°

F (+ 5

°

F)

50% (+ 5%)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Non-Operating Limits

+5

°

C to +50

°

C (+41

°

F to +122

°

F)

Gradient 25

°

C/h (77

°

F/h)

5 to 95% (Gradient 30%)

+28

°

C (+82.4

°

F)

0.024 kg water/kg dry air

Dry bulb temperature range

Shipping Limits

-35

°

C to +65

°

C (-31

°

F to +149

°

F)

Gradient 25

°

C/h (77

°

F/h)

Relative humidity (non-condensing) 5 to 95% Gradient 30%/h

Acoustic Power at Room Temperature +20

°

C (+68

°

F)

Lw(A) 6.3 Bels

System Running

Lw(A) 6.1 Bels

System Idle

A-6 User's Guide

Power Cables

PDU-2-4-M-32A

AC (32A)

Cable type

Connector type

1 per PDU

3 x AWG10 (3 x 6 mm 2 / #10US)

IEC60309-32A

It is mandatory for power lines and terminal boxes to be located within the immediate vicinity of the system and to be easily accessible. Each power line must be connected to a separate, independent electrical panel and bipolar circuit breaker.

PDUs require an extra cable length of 1.5 meters for connection inside the cabinet.

Electrical Specifications

(power supplies are auto-sensing and auto-ranging)

Current draw

Power consumption

Thermal dissipation

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

11 A max. at 200 VAC input

2400 VA per full CSS module

2400 W / 8190 BTU per full CSS module

Europe

230 VAC (Phase / Neutral)

207 - 244 VAC

50 Hz 1%

United States of America

208 VAC (Phase / Neutral)

182 - 229 VAC

60 Hz 0.3%

Japan

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

200 VAC (Phase / Neutral)

188 - 212 VAC

60 Hz 0.2%

Brazil

220 VAC (Phase / Neutral)

212 - 231 VAC

60 Hz 2%

Breaker Protection (Mains Power)

PDU-2-4-M-32A

Maximum inrush current

32A Curve C

210A / per quarter period

Table 67.

NovaScale 5245 Server specifications

Server Specifications A-7

NovaScale 5325 Server Specifications

NovaScale 5325 Servers are delivered rack-mounted in 40U cabinets.

The following web site may be consulted for general site preparation information: http://www.cs.bull.net/aise

.

1300H

Height:

Width:

Depth:

Weight (max):

Cabinet Dimensions / Weight

Unpacked

195.5 cm (77.0 in)

60.0 cm (23.6 in)

129.5 cm (51.0 in)

1300H

Height:

Width:

Depth:

670 kg (1427 lb) Weight (max):

Service Clearance

Packed

200.0 cm (78.7 in)

80.0 cm (31.5 in)

140.0 cm (55.1 in)

700 kg (1491 lb)

Front

Rear

Side (free side)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Pressure / Elevation

150 cm

100 cm

100 cm

Operating Limits

+15

°

C to +30

°

C (+59

°

F to +86

°

F)

Gradient 5

°

C/h (41

°

F/h)

35 to 60% (Gradient 5%/h)

+24

°

C (+75.2

°

F)

0.019 kg water/kg dry air

Sea level < 2500 m

Temperature

Hygrometry

Optimum Operational Reliability

+ 22

°

C (+ 3

°

C) (+ 72

°

F (+ 5

°

F)

50% (+ 5%)

Dry bulb temperature range

Relative humidity (non-condensing)

Max. wet bulb temperature

Moisture content

Non-Operating Limits

+5

°

C to +50

°

C (+41

°

F to +122

°

F)

Gradient 25

°

C/h (77

°

F/h)

5 to 95% (Gradient 30%)

+28

°

C (+82.4

°

F)

0.024 kg water/kg dry air

Dry bulb temperature range

Shipping Limits

-35

°

C to +65

°

C (-31

°

F to +149

°

F)

Gradient 25

°

C/h (77

°

F/h)

Relative humidity (non-condensing) 5 to 95% Gradient 30%/h

Acoustic Power at Room Temperature +20

°

C (+68

°

F)

Lw(A) 6.3 Bels

System Running

Lw(A) 6.1 Bels

System Idle

A-8 User's Guide

Power Cables

PDU-2-4-M-32A

AC (32A)

Cable type

Connector type

1 per PDU

3 x AWG10 (3 x 6 mm 2 / #10US)

IEC60309-32A

It is mandatory for power lines and terminal boxes to be located within the immediate vicinity of the system and to be easily accessible. Each power line must be connected to a separate, independent electrical panel and bipolar circuit breaker.

PDUs require an extra cable length of 1.5 meters for connection inside the cabinet.

Electrical Specifications

(power supplies are auto-sensing and auto-ranging)

Current draw

Power consumption

Thermal dissipation

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

11 A max. at 200 VAC input

2400 VA per full CSS module

2400 W / 8190 BTU per full CSS module

Europe

230 VAC (Phase / Neutral)

207 - 244 VAC

50 Hz 1%

United States of America

208 VAC (Phase / Neutral)

182 - 229 VAC

60 Hz 0.3%

Japan

Nominal voltage

Voltage range

Frequency

Nominal voltage

Voltage range

Frequency

200 VAC (Phase / Neutral)

188 - 212 VAC

60 Hz 0.2%

Brazil

220 VAC (Phase / Neutral)

212 - 231 VAC

60 Hz 2%

Breaker Protection (Mains Power)

PDU-2-4-M-32A

Maximum inrush current

32A Curve C

210A / per quarter period

Table 68.

NovaScale 5325 Server specifications

Server Specifications A-9

A-10 User's Guide

Glossary

A

AC: Alternating Current generated by the power supply. See DC.

ACPI: Advanced Configuration and Power Interface.

An industry specification for the efficient handling of power consumption in desktop and mobile computers. ACPI specifies how a computer's BIOS, operating system, and peripheral devices communicate with each other about power usage.

Address: A label, name or number that identifies a location in a computer memory.

AMI: American Megatrends Incorporated.

ANSI: American National Standards Institute.

API: Application Program Interface. The specific method prescribed by a computer operating system or by an application program by which a programmer writing an application program can make requests of the operating system or another application.

Archive: (Archive file). A file that is a copy of a history file. When a history file is archived, all messages are removed from the history file.

ASCII: American National Standard Code for

Information Interchange. A standard number assigned to each of the alphanumeric characters and keyboard control code keys to enable the transfer of information between different types of computers and peripherals.

B

Backup: A copy of data for safe-keeping. The data is copied form computer memory or disk to a floppy disk, magnetic tape or other media.

Backup battery: The battery in a computer that maintains real-time clock and configuration data when power is removed.

Baud rate: The speed at which data is transmitted during serial communication.

BERR: Bus Error signal pin used to signal a global machine check abort condition.

BINIT: Bus Initialization signal pin used to signal a global fatal machine check condition.

BIOS: Basic Input / Output System. A program stored in flash EPROM or ROM that controls the system startup process.

BIST: Built-In Self-Test. See POST.

Bit: Derived from BInary digiT. A bit is the smallest unit of information a computer handles.

BTU: British Thermal Unit.

Byte: A group of eight binary digits (bit) long that represents a letter, number, or typographic symbol.

C

Cache Memory: A very fast, limited portion of RAM set aside for temporary storage of data for direct access by the microprocessor.

CD-ROM: Compact DisK Read-Only Memory.

High-capacity read-only memory in the form of an optically readable compact disk.

Cell: The smallest set of hardware components allocated to a single OS. A cell is functionally defined by:

- the number of available processors

- memory capacity

- I/O channel capacity.

CellBlock: A group of interconnected cells within a single domain. See Central Subsystem.

Central Subsystem: A group of interconnected cells gathered within a single domain. See CellBlock.

Chained DIBs: Two DIBs can be inter-connected to house 4 SCSI RAID disks, 1 DVD-ROM drive, 1 USB port. See DIB and IPD.

Chip: Synonym for integrated circuit. See IC.

Clipping: A PAM Event filter criterion. Clipping is defined on a Count / Time basis aimed at routing a pre-defined number of messages only. Identical messages are counted and when the number of messages indicated in the Count field is reached within the period of time indicated in the Time field, no other messages will be selected for routing.

CMC: Corrected Memory Check condition is signaled when a hardware corrects a machine check error or when a MCA condition is corrected by firmware.

CMCI: Corrected Memory Check Interrupt.

Glossary G-1

CMCV: Corrected Memory Check Vector.

CMOS: Complementary Metal Oxide Semiconductor.

A type of low-power integrated circuits. System startup parameters are stored in CMOS memory.

They can be changed via the system setup utility.

COM: Component Object Model. Microsoft technology for component based application development under Windows.

COM +: Component Object Model +. Microsoft technology for component based application development under Windows. The external part of the PAM software package is a COM+ application.

COM1 or COM2: The name assigned to a serial port to set or change its address. See Serial Port.

Command: An instruction that directs the computer to perform a specific operation.

Configuration: The way in which a computer is set up to operate. Configurable options include CPU speed, serial port designation, memory allocation,

...

Configuration Tasks: A PAM feature used to configure and customize the server.

Control Pane: One of the three areas of the PAM web page. When an item is selected in the PAM

Tree pane, details and related commands are displayed in the Control pane. See PAM Tree pane and Status pane.

Core Unit: A main CSS module unit interconnecting the MIO, MQB, MSX and MFL boards. See MIO,

MQB, MSX, MFL.

COS: Cluster Operating System.

CPE: Corrected Platform Error.

CPEI: Corrected Platform Error Interrupt.

CPU: Central Processing Unit. See Microprocessor and Socket.

CSE: Customer Service Engineer.

CSS: Central Sub-System. See CellBlock.

CSS Module: A MidPlane with all its connected components (QBBs, IO boards, PMB) and utility devices. See Module.

D

D2D: DC to DC converter.

DC: Direct Current generated by the power supply.

See AC.

Default Setting: The factory setting your server uses unless instructed otherwise.

Density: The capacity of information (bytes) that can be packed into a storage device.

Device Driver: A software program used by a computer to recognize and operate hardware.

DIB: Device Interface Board. The DIB provides the necessary electronics for the Internal Peripheral

Drawer. See IPD and Chained DIBs.

DIG64: Developer Interface Guide for IA64.

DIM Code: Device Initialization Manager. Initializes different BUSes during the BIOS POST.

DIMM: Dual In-line Memory Module - the smallest system memory component.

Disk Drive: A device that stores data on a hard or floppy disk. A floppy disk drive requires a floppy disk to be inserted. A hard disk drive has a permanently encased hard disk.

DMA: Direct Memory Access. Allows data to be sent directly from a component (e.g. disk drive) to the memory on the motherboard). The microprocessor does not take part in data transfer enhanced system performance.

DMI: Desktop Management Interface. An industry framework for managing and keeping track of hardware and software components in a system of personal computers from a central location.

DNS: Domain Name Server. A server that retains the addresses and routing information for TCP/IP

LAN users.

Domain: is the coherent set of resources allocated to run a customer activity, i.e. the association -at boot time- of a Partition, an OS instance (including applications) and associated LUNs and an execution context including execution modes and persistent information (e.g. time, date of the OS instance). Domain definitions and initializations are performed via PAM. A Domain can be modified to run the same OS instance on a different Partition.

When a Domain is running, its resources are neither visible nor accessible to other running

Domains.

Domain Identity: a PAM Domain management logical resource. This resource contains context information related to the Customer activity running in a domain. The most visible attribute of this resource is the name that the Customer gives to the activity. For each domain created, the Domain management feature allows the operator to define a new activity or choose an activity from the list of existing activities. See Domain.

Domain Manager: A PAM feature used to power on / off and manage server domains. See Domain.

DPS: Distributed Power Supply.

G-2 User's Guide

DRAM: Dynamic Random Access Memory is the most common type of random access memory

(RAM).

E

ECC: Error Correcting Code.

EEPROM: Electrically Erasable Programmable

Read-Only Memory. A type of memory device that stores password and configuration data. See also

EPROM.

EFI: Extensible Firmware Interface.

EFIMTA: EFI Modular Test Architecture.

EFI Shell: The EFI (Extensible Firmware Interface)

Shell is a simple, interactive user interface that allows EFI device drivers to be loaded, EFI applications to be launched, and operating systems to be booted. In addition, the EFI Shell provides a set of basic commands used to manage files and the system environment variables. See Shell.

EMI: Electro-Magnetic Interference.

EPROM: Erasable Programmable Read-Only

Memory. A type of memory device that is used to store the system BIOS code. This code is not lost when the computer is powered off.

ERC: Error and Reset Controller. This controller allows PAM software to control error detection and reset propagation within each pre-defined CSS partition. The ERC is initialized by PAM software to ensure a partition-contained distribution of the reset, error, interrupt and event signals; and to contribute to error signaling and localization at platform level.

ERP: Error Recovery Procedure.

ESD: ElectroStatic Discharge. An undesirable discharge of static electricity that can damage equipment and degrade electrical circuitry.

Event: The generation of a message (event message) by a software component and that is directed to the Event Manager.

Event address: Defines the destination for a message sent over a specified event channel. An address is one of: the name of a history file (for the

HISTORY channel), an e-mail address (for the

EMAIL channel), the name of a user group (for the

WEB channel), the SNMP Manager IP address (for the SNMP channel).

Event channel: Defines how the Event Manager sends an event message. An event channel is one of: HISTORY (the message is logged in a history file), EMAIL (the message is sent to an e-mail address), WEB (the message is stored for analysis from the PAM web user interface), SNMP (the message is sent as an SNMP trap to the selected

SNMP application).

Event filter: A list of selected messages among all possible event messages. If an event message is not included in the filter, the Event Manager discards the message.

Event Manager: A PAM feature used to forward event messages over a configured event channel.

See Event.

Event message: A message sent by a software component to the Event Manager for routing to a destination that is configured by an administrator.

Event subscription: An object that defines the event channel, address, and filter for sending an event message. If no such object is defined, the event message is discarded.

Exclusion: Logical removal of a redundant faulty hardware element until it has been repaired or replaced. The hardware element remains physically present in the configuration, but is no longer detected by PAM software and can no longer be used by a domain.

External Disk Subsystem: Disk subsystem housed inside the NovaScale cabinet.

F

Fail-over: Failover is a backup operational mode in which the functions of a system component (such as a processor, server, network, or database, for example) are assumed by secondary system components when the primary component becomes unavailable through either failure or scheduled down time.

FAME: Flexible Architecture for Multiple

Environments.

FAST WIDE: A standard 16-bit SCSI interface providing synchronous data transfers of up to 10

MHz, with a transfer speed of 20M bytes per second.

FC: Fibre Channel.

Glossary G-3

FCAL: Fibre Channel Arbitrated Loop.

FCA: Fibre Channel Adapter.

FCBQ: Fan Control Board for QBB.

FCBS: Fan Control Board for SPS.

FDA: Fibre Disk Array.

FDD: Floppy Disk Drive.

Flash EPROM: Flash Erasable Programmable

Read-Only Memory. A type of memory device that is used to store the the system firmware code. This code can be replaced by an updated code from a floppy disk, but is not lost when the computer is powered off.

Firewall: A set of related programs, located at a network gateway server, that protects the resources of a private network from users from other networks.

Firmware: an ordered set of instructions and data stored to be functionally independent of main storage.

Format: The process used to organize a hard or floppy disk into sectors so that it can accept data.

Formatting destroys all previous data on the disk.

FPB: FAME Power Board (FAME: Flexible

Architecture for Multiple Environments).

FPGA: Field Programmable Gate Array. A gate array that can reprogrammed at run time.

FRB: Fault Resilient Boot. A server management feature. FRB attempts to boot a system using the alternate processor or DIMM.

FRU: Field Replaceable Unit. A component that is replaced or added by Customer Service Engineers as a single entity.

FSS: FAME Scalability Switch. Each CSS Module is equipped with 2 Scalability Port Switches providing high speed bi-directional links between server components. See SPS.

FTP: File Transfer Protocol. A standard Internet protocol: the simplest way of exchanging files between computers on the Internet. FTP is an application protocol that uses Internet TCP/IP protocols. FTP is commonly used to transfer Web page files from their creator to the computer that acts as their server for everyone on the Internet. It is also commonly used to download programs and other files from other servers.

FWH: FirmWare Hub.

Global MCA: Machine Check Abort is visible to all processors, in a multiprocessor system and will force all of them to enter machine check abort.

GUI: Graphical User Interface.

GTS: Global Telecontrol Server.

H

HA: High Availability. Refers to a system or component that is continuously operational for a desirably long length of time.

HAL: Hardware Abstraction Layer.

HA CMP: High Availability Clustered

MultiProcessing.

Hard Disk Drive: HDD. See Disk Drive.

Hardware: The physical parts of a system, including the keyboard, monitor, disk drives, cables and circuit cards.

Hardware Monitor: A PAM feature used to supervise server operation.

HBA: Host Bus Adapter.

HDD: Hard Disk Drive. See Disk Drive.

History File: A file in which the History Manager logs informative messages or error messages relating to system activity. Messages are sent from source components to target components.

History Manager: The component running on the

PAP Windows operating system that logs messages to history files.

HMMIO Space: High Memory IO Space.

HPB: Hot Plug Board. This board provides an interlock switch on each IO Box PCI slot for hotswapping PCI boards. See P-HPB.

HPC: High Performance Computing.

Hot plugging: The operation of adding a component without interrupting system activity.

Hot swapping: The operation of removing and replacing a faulty component without interrupting system activity.

HTTP: HyperText Transfer Protocol. In the World

Wide Web, a protocol that facilitates the transfer of hypertext-based files between local and remote systems.

HW Identifier: Number (0 - F) used to identify

Cellblock components. This number is identical to

PMB code-wheel position.

G

GB: GigaByte: 1,073,741,824 bytes. See Byte.

G-4 User's Guide

I

I2C: Intra Integrated Circuit. The I2C (Inter-IC) bus is a bi-directional two-wire serial bus that provides a communication link between integrated circuits

(ICs).

The I2C bus supports 7-bit and 10-bit address space devices and devices that operate under different voltages.

IA64: is a 64-bit Intel processor Architecture based on Explicitly Parallel Instruction Computing (EPIC).

The Itanium processor is the first in the Intel line of

IA-64 processors.

IB: Infini Band.

IC: Integrated Circuit. An electronic device that contains miniaturized circuitry. See Chip.

ICH2: I/O Controller Hub 2, component that contains the fundamental I/O interfaces required by the system. Flash memory, Keyboard, USB and IDE device interface.

ICH4: I/O Controller Hub 4.

ICMB: Intelligent Chassis Management Bus.

ID: A number which uniquely identifies a device on a bus.

IDE: Integrated Drive Electronics. A type of hard disk drive with the control circuitry located inside the disk drive rather than on a drive controller card.

Identity: See Domain Identity.

IIS: Internet Information Server. A group of Internet servers (including a Web or HTTP server and a FTP server) with additional capabilities for Microsoft 

Windows  NT and Microsoft Windows (and later) operating systems.

I/O: Input /Output. Describes any operation, program, or device that transfers data to or from a computer.

Interface: A connection between a computer and a peripheral device enabling the exchange of data.

See Parallel Port and Serial Port.

Internal Disk Subsystem: Disk subsystem housed inside the NovaScale Internal Peripheral Drawer

(IPD).

IOB: Input / Output Board. The IOB connects up to

11 PCI-X boards.

IOC: Input / Output Board Compact. The IOC connects up to 6 PCI-X boards.

IOL: I/O Board Legacy. The IOL provides:

- I/O controller Hub

- USB ports

- 10/100/1000 Ethernet controller

- Video controller

- Serial / debug port

IOR: I/O Board Riser. The IOR provides:

- I/O controller Hub

- USB ports

- 10/100/1000 Ethernet controller

- Video controller

- Serial / debug port

IP: Internet Protocol. The protocol by which data is sent from one computer to another via the Internet.

Each computer (known as a host) on the Internet has at least one IP address that uniquely identifies it from all other computers on the Internet.

IPD: Internal Peripheral Drawer. The IPD houses legacy peripherals (DVD-Rom drive, USB port) and

SCSI system disks. See DIB and Chained DIBs.

IPF: Itanium Processor Family.

IPL: Initial Program Load. It defines the firmware functional phases during the system initialization.

IPMB: Intelligent Platform Management Bus.

IPMI: Intelligent Platform Management Interface.

ISA: Industry Standard Architecture. An industry standard for computers and circuit cards that transfer 16 bits of data at a time.

J

Jumper: A small electrical connector used for configuration on computer hardware.

K

KVM: Keyboard Video Monitor.

KVM switch: the Keyboard Video Monitor switch allows the use of a single keyboard, monitor and mouse for more than one module.

L

LAN: Local Area Network. A group of computers linked together within a limited area to exchange data.

Glossary G-5

LD: Logical Disk. A Storeway FDA 1x00/2x00 logical disk (or LUN) is visible to the OS as a Disk.

See LUN and PD (Physical Disk).

LED: Light Emitting Diode. A small electronic device that glows when current flows through it.

Legacy Application: An application in which a company or organization has already invested considerable time and money. Typically, legacy applications are database management systems

(DBMSs) running on mainframes or minicomputers.

Licensing Number: When you install an application protected by a system serial number, you are requested to supply this serial number.For optimum flexibility, PAM software allows you to replace the physical serial number by a logical licensing number so that you can run the application on any physical partition and, in the case of extended systems, on any of the Central Subsystems within the extended configuration.

LID: Local Interrupt Identifier (CPU).

Local Disk Subsystem: Disk subsystem housed inside the NovaScale cabinet and not connected to a

SAN.

Local MCA: Machine Check Abort is detected and handled by a single processor and is invisible to the other processor.

Locking: Means of functionally limiting access to certain hardware elements. Locked hardware elements can no longer be accessed by the current domain, but are still physically available for use by other domains. Previously locked elements can be unlocked so that they can be accessed by the domain.

LPT1 or LPT2: The name assigned to a parallel port to specify its address. See Parallel Port.

LS240: Laser Servo super diskette holding up to

240 Mb.

LUN: Logical Unit Number. Term used to designate

Logical Storage Units (logical disks) defined through the configuration of physical disks stored in a mass storage cabinet.

LVDS: Low Voltage Differential SCSI.

M

MAESTRO: Machine Administration Embedded

Software Real Time Oriented.

Part of the PAM software package embedded on the PMB board.

MCA: Machine Check Abort.

See also Local MCA and Global MCA.

Memory: Computer circuitry that stores data and programs. See RAM and ROM.

Memory bank: The minimum quantity of memory used by the system. It physically consists of four memory DIMMs.

MFL: Midplane Fan & Logistics board. The MFL houses the Fan Boxes and is connected to the MIO and MQB. See MIO, MQB.

Microprocessor: An integrated circuit that processes data and controls basic computer functions.

Midplane: Mid-Plane. All system hardware components are connected to the Midplane.

MIMD: Multiple Instruction Multiple Data

MIO: Midplane Input / Output board. The MIO connects one or two IOC boards and the PMB. See

Core Unit.

Mirrored volumes: A mirrored volume is a fault-tolerant volume that duplicates your data on two physical disks. If one of the physical disks fails, the data on the failed disk becomes unavailable, but the system continues to operate using the unaffected disk.

Module: a Midplane Board with all its connected components and utility devices. See CSS Module and MP.

MQB: Midplane QBB board. The MQB connects one or two QBBs and one or two IPDs. See QBB and IPD.

MSX: Midplane SPS & XPS board. The MSX houses a B-SPS switch and is connected to the MIO and the MQB. There are two MSX boards in a CSS module. All SP connections between a QBB and an

IOC use an MSX. See B-SPS, MIO, MQB.

MTBF: Mean Time Between Failure. An indicator of expected system reliability calculated on a statistical basis from the known failure rates of various components of the system. Note: MTBF is usually expressed in hours.

Multicore: Presence of two or more processors on a single chip.

Multimedia: Information presented through more than one type of media. On computer systems, this media includes sound, graphics, animation and text.

G-6 User's Guide

Multitasking: The ability to perform several tasks simultaneously. Multitasking allows you to run multiple applications at the same time and exchange information among them. See Task.

Multithreading: The ability of a processor core to execute more than one independent instruction thread simultaneously. As the core comprises two complete context registers, it is able to switch rapidly from one instruction thread to another.

N

NFS: Network File System. A proprietary distributed file system that is widely used by TCP/IP vendors.

Note: NFS allows different computer systems to share files, and uses user datagram protocol (UDP) for data transfer.

NMI: Non-Maskable Interrupt.

NUMA: Non Uniform Memory Access. A method of configuring a cluster of microprocessors in a multiprocessing system so that they can share memory locally, improving performance and the ability of the system to be expanded.

nsh: nsh stands for new shell. See Shell and EFI

Shell.

NVRAM: Non Volatile Random Access Memory. A type of RAM that retains its contents even when the computer is powered off. See RAM and SRAM.

O

OF: Open Firmware. Firmware controlling a computer prior to the Operating System.

Operating System: See OS.

OS: Operating System. The software which manages computer resources and provides the operating environment for application programs.

P

PAL: Processor Abstraction Layer: processor firmware that abstracts processor implementation differences. See also SAL.

PAM: Platform Administration & Maintenance.

PAM software: Platform Administration &

Maintenance software. One part (PAP application and the PamSite WEB site) runs on the PAP unit. The other part (MAESTRO) is embedded on the PMB board.

PAM Tree pane: One of the three areas of the PAM web page. Server hardware presence and functional status are displayed in the PAM Tree pane. See Status pane and Control pane.

PAP unit: Platform Administration Processor unit. The

PC hosting all server administration software.

PAP application: Platform Administration Processor application. Part of PAM software, PAP application is a Windows COM+ application running on PAP unit.

Parallel Port: Connector allowing the transfer of data between the computer and a parallel device.

PARM request: the PARM application is designed to handle Requests issued by the CSE (Customer

Service Engineer)

Partition: Division of storage space on a hard disk into separate areas so that the operating system treats them as separate disk drives.

Password: A security feature that prevents an unauthorized user from operating the system.

PCI: Peripheral Component Interconnect. Bus architecture supporting high-performance peripherals.

PD: Physical Disk. A Storeway FDA 1300/2300 physical disk is not visible to the OS. See LD.

PDU: Power Distribution Unit. Power bus used for the connection of peripheral system components.

Permanence: Property of a history file that determines whether or not the history file can be modified or deleted from the PAM user interface.

Permanence is either Static (cannot be modified) or

Dynamic (can be modified).

P-HPB: PCI Hot Plug Board. This board provides an interlock switch on each IO Box PCI slot for hot-swapping PCI boards. See HPB.

PIC: Platform Instrumentation Control.

ping: A basic Internet program that lets you verify that a particular IP address exists and can accept requests. The verb "to ping" means the act of using the ping utility or command.

PIROM: Processor Information ROM. Processor

Information ROM (PIROM) contains information about the specific processor in which it resides. This information includes robust addressing headers to allow for flexible programming and forward compatibility, core and L2 cache electrical specifications, processor part and S-spec numbers, and a 64-bit processor number.

Glossary G-7

PMB: Platform Management Board. Links the server to the PAP unit.

PNP: Plug aNd Play. The ability to plug a device into a computer and have the computer recognize that the device is there.

POST: Power On Self Test. When power is turned on, POST (Power-On Self-Test) is the diagnostic testing sequence (or "starting program") that a computer runs to determine if hardware is working correctly.

PROM: Programmable Read-Only Memory.

PUID: PAM Universal/Unique IDentifier. PAM software allocates a PUID (PAM Universal / Unique

Identifier) to each hardware / software object to guarantee unambiguous identification.

The PUID for each hardware element can be obtained by hovering the mouse over the corresponding element in the PAM tree, e.g.:

PAM:/CELLSBLOCK_<NAME>/MODULE_x/QBB_y

/CPU_y.

Q

QBB: Quad Brick Board. The QBB is the heart of the

Bull NovaScale Server, housing 4 Itanium 2 processors and 16 DIMMs. Each QBB communicates with other CSS Module components via 2 high-speed bidirectional Scalability Port

Switches.

See SPS or FSS.

R

RAID: Redundant Array of Independent Disks. A method of combining hard disk drives into one logical storage unit for disk-fault tolerance.

RAM: Random Access Memory. A temporary storage area for data and programs. This type of memory must be periodically refreshed to maintain valid data and is lost when the computer is powered off. See NVRAM and SRAM.

RAS: Reliability, Availability, Serviceability.

Real-time clock: The Integrated Circuit in a computer that maintains the time and date.

RFI: Radio Frequency Interference.

Ring: The CSS module interconnection ring comprises the cables used to interconnect two, three or four CSS modules.

RJ45: 8-contact regular jack.

RMC: Remote Maintenance Console.

ROM: Read-Only Memory. A type of memory device that is used to store the system BIOS code. This code cannot be altered and is not lost when the computer is powered off. See BIOS, EPROM and

Flash EPROM.

RS-232 Port: An industry standard serial port. See

Serial Port.

RSF: Remote Service Facilities.

RTC: Real Time Clock.

S

[email protected]: SAN Administration Tool.

SAL: System Abstraction Layer. Firmware that abstract system implementation differences in IA-64 platform. See also PAL.

SAN: Storage Area Network. A high-speed special-purpose network that interconnects different kinds of data storage devices with associated data servers on behalf of a larger network of users.

SAPIC: Streamlined Advanced Programmable

Interrupt Controller message.

SBE: Single Bit Error.

Scheme: Configuration file ensuring optimum use and compatibility of the physical and logical resources used to simultaneously run multiple domains.

SCI: Scalable Coherent Interface.

SCSI: Small Computer System Interface. An input and output bus that provides a standard interface used to connect peripherals such as disks or tape drives in a daisy chain.

SDR: Sensor Data Record.

SDRAM: Synchronous Dynamic Random Access

Memory. A type of DRAM that runs at faster clock speeds than conventional memory. See DRAM.

SEL: System Event Log. A record of system management events. The information stored includes the name of the event, the date and time the event occurred and event data. Event data may include

POST error codes that reflect hardware errors or software conflicts within the system.

Serial Communication: Data sent sequentially, one bit at a time.

Serial Port: Connector that allows the transfer of data between the computer and a serial device.

See COM1 or COM 2.Shell is a Unix term for the interactive user interface with an operating system.

G-8 User's Guide

SIO: Server I/O / Super I/O.

Shell: The Shell is the layer of programming that understands and executes the commands a user enters. As the outer layer of an operating system, the Shell can be contrasted with the kernel, the inmost layer or core of services of an operating system. See EFI Shell.

SIOH: Server I/O Hub. This component provides a connection point between various I/O bridge components and the Intel 870 chipset.

Sideband: This part of the CSS module inter-connection ring comprises logistic cables

(errors, commands, resets). See Ring.

SMBIOS: System Management BIOS.

SM-BUS: System Management Bus.

SMIC: Server Management Interface Chip.

SMP: Symmetrical Multi Processor. The processing of programs by multiple processors that share a common operating system and memory.

SNC: Scalable Node Controller. The processor system bus interface and memory controller for the

Intel870 chipset. The SNC supports both the

Itanium2 processors, DDR SDRAM main memory, a

Firmware Hub Interface to support multiple

Firmware hubs, and two scalability ports for access to I/O and coherent memory on other nodes, through the FSS.

SNM: System Network Module.

SNMP: Simple Network Management Protocol. The protocol governing network management and the monitoring of network devices and their functions.

Socket: Central Processing Unit mutlticore interface.

Each socket can house 1 or 2 processor cores. See

Microprocessor and CPU.

Source: Each message refers to a source (the resource that generated the message) and a target

(the component referred to in the message). This feature can be allows messages to be filtered according to one or more Source string(s) and is particularly useful for debugging and troubleshooting. See Target.

SPD: Serial Presence Detect. DIMM PROM.

SPS: Scalability Port Switch. Each CSS Module is equipped with 2 Scalability Port Switches providing high speed bi-directional links between system components. See FSS.

SRAM: Static RAM. A temporary storage area for data and programs. This type of memory does not need to be refreshed, but is lost when the system is powered off. See NVRAM and RAM.

SSI: Server System Infrastructure.

Status Pane: One of the three areas of the PAM web page. Provides quick access to CSS Module availability status, server functional status, and pending event message information. See also

Control pane and PAM Tree pane.

SVGA: Super Video Graphics Array.

T

Target: Each message refers to a target (the component referred to in the message), identified by its PUID, and a source (the component that generated the message).This feature allows messages to be filtered according to one or more

Target string(s) and is particularly useful for debugging and troubleshooting. See Source and

PUID.

Task: Each message refers to a target (the component referred to in the message), identified by its PUID, and a source (the component that generated the message).This feature allows messages to be filtered according to one or more

Target string(s) and is particularly useful for debugging and troubleshooting. See Source and

PUID.

TCP: Transmission Control Protocol. A set of rules

(protocol) used along with the Internet Protocol (IP) to send data in the form of message units between computers over the Internet.

TCP/IP: Transmission Control Protocol / Internet

Protocol. The basic communication language or protocol of the Internet.

T&D: Tests and Diagnostics.

Thresholding: A PAM Event filter criterion.

Thresholding is defined on a Count / Time basis aimed at routing significant messages only. Identical messages are counted and when the number of messages indicated in the Count field is reached within the period of time indicated in the Time field, this message is selected for routing.

U

UART: a Universal Asynchronous Receiver

Transmitter. The microchip with programming that controls a computer interface to its attached serial devices.

ULTRA SCSI: An enhanced standard 16-bit SCSI interface providing synchronous data transfers of up to 20 MHz, with a transfer speed of 40M bytes per second. It is also called Fast-20 SCSI.

Glossary G-9

UML: Unified Modeling Language. A standard notation for the modeling of real-world objects as a first step in developing an object-oriented design methodology.

UPS: Uninterruptible Power Supply. A device that allows uninterrupted operation if the primary power source is lost. It also provides protection from power surges.

URL: Uniform / Universal Resource Locator. The address of a file (resource) accessible on the

Internet.

USB: Universal Serial Bus. A plug-and-play interface between a computer and add-on devices. The USB interface allows a new device to be added to your computer without having to add an adapter card or even having to turn the computer off.

V

VCC: Voltage Continuous Current.

VGA: Video Graphics Array.

VI: Virtual Interface.

Visibility: A property of a history file. Visibility is either System (the history file is predefined by the

PAM software and is visible only to an administrator) or User (the history file is created by an administrator and is visible to both an administrator and an operator).

VLAN: Virtual Local Area Network. A local area network with a definition that maps workstations on some other basis than geographic location (for example, by department, type of user, or primary application).

VxWORKS: Platform Management Board Operating

System.

W

WAN: Wide Area Network. Geographically dispersed telecommunications network. The term distinguishes a broader telecommunication structure from a local area network (LAN).

WBEM: Web Based Enterprise Management.

WMI: Windows Management Interface.

WOL: A feature that provides the ability to remotely power on a system through a network connection.

X

XML: eXtended MarkUp Language. A flexible way to create common information formats and share both the format and the data on the World Wide

Web, intranets, and elsewhere.

XSP: eXtended Scalable Port.

Y

No entries.

Z

No entries.

G-10 User's Guide

Index

A

Access, front door, 1-20

Action Request Package

default, creating, 4-51

filtering, 4-53

troubleshooting tools, creating, 4-51

Archive

history, 4-38 viewing, online, 4-38

Autocall settings, checking, 4-48

Autocalls

configuring, 5-20

FTP parameters, 5-20

Automatic restart, 5-52

B

Back Up, PAM software, 5-26

BIOS, POST codes, 3-43

BIOS info, domain, 3-33

Boot, options, 5-7

Boot manager, EFI, 5-7

C

CD-ROM drive, 1-14

Channels, enabling / disabling, 5-140

Checking

environmental conditions, 4-46

events, 4-47 fault status, 4-47

hardware availability, 4-46

hardware connections, 4-47 histories, 4-47

PMB, 4-49

power status, 4-47

SNMP settings, 4-48

temperature status, 4-47

Checking

Autocall settings, 4-48

MAESTRO version, 4-48

PAM version, 4-48 writing rules, 4-48

Checks, server status, 2-6

Clipping, 5-148

Components, 5085, 1-7

Configuration

requirements, assessing, 5-31

saving the current snapshot, 3-11

Configuring, event messaging, 5-133

Connecting to, server domain

Enterprise LAN, 2-19

Web, 2-20

Connection, hardware, 3-43

Console, 1-15

opening / closing, 1-21

toggling, 2-9

Creating, Action Request Package, 4-51

CSS , functional status / domain state, 4-43

CSS hardware, functional status, 4-4

CSS Module, PMB, 4-50

CSS module, 1-13

availability status, 2-7, 4-4

power, 4-19

thermal zone, 4-17

Custom Package, creating, 4-54

Customer information, modifying, 5-19

Customizing, PAM settings, 5-22

D

Data disks (SCSI), configuring, 5-5

Default schemes, updating, 5-49

Delivery, system, 1-2

Details pane, PAM, 2-6

DIB, chained, 1-13

DIMMs, 1-13

Disks, 1-14

configuring SCSI data disks, 5-5

Documentation

highlighting, xv

preface, iii

related publications, xv

Domain

BIOS info, 3-33

deleting, 3-26

dump, 3-24, 3-43

force power OFF, 3-43

force power off, 3-21

functional status, 3-29

hardware resources, 3-35

incidents, 3-42

power down, 2-10, 2-11

power logs, 3-31

power OFF, 3-43

power off, 3-18

power on, 3-14

power ON , 3-43

power up, 2-10, 2-11

powering sequences, 3-32

request logs, 3-34

reset, 3-25, 3-43

Domain configuration

adding domains, 3-10 replacing, 3-10

Domain identity. See identity

Domain manager, 3-2

Domain scheme. See scheme

Domains

configuring, 5-28

incidents, 3-43

managing, 3-1

powering ON / OFF, 4-48

Dump, domain, 3-24

DVD/CD-ROM drive, 1-13

E

E-mail

creating an e-mail account, 5-138

creating an e-mail server, 5-136

Index X-1

deleting an e-mail account, 5-139

deleting an e-mail server, 5-137

editing e-mail account attributes, 5-139

editing e-mail server attributes, 5-137

EFI

boot manager, 5-7 boot manager options, 5-7

file transfer protocol, 5-15

manual network configuration, 5-14 network setup and configuration, 5-14

shell, 5-9

EFI boot, options, 5-7

EFI shell

command syntax, 5-9

commands, 5-11 script, 5-11

starting, 5-9

EFI utilities, using, 5-6

Electrical safety, xviii

Enterprise LAN, server domain

Linux, connecting, 2-19

Windows, connecting, 2-19

Environmental conditions, checking, 4-46

Ethernet hub, 1-19

Ethernet ports, 1-13, 1-14

Event filter

advanced filtering criteria, 5-148

creating a new filter, 5-154

deleting, 5-155 editing filter attributes, 5-155

preselecting, 5-153

standard filtering criteria, 5-145

Event message, status, 4-4

Event messages

acknowledging, 4-34

consulting, 4-33

customizing, 5-133

e-mail, viewing, 4-35

enabling / disabling channels, 5-140

managing, 4-31

severity, 5-148

severity levels, 4-32

sorting / locating, 4-35

source, 5-148

subscription, 5-133

target, 5-148

viewing, 4-31

Event subscription

See Subscriptions, 5-141

flowchart, 5-135

Event subscriptions, creating, 5-132

Events, checking, 4-47

Example scheme mono-domain

all resources, 5-69

part of resources, 5-83

multi-domain

all resources, 5-96

part of resources, 5-111

Exclude / include, monitoring, 4-15

Excluding

clocks, 4-27

hardware, 4-23

hardware element, 4-47

X-2 User's Guide

sidebands, 4-27

XPS cables, 4-27

Excluding

hardware, 4-23

SPS, 4-27

Exclusion, hardware, 3-43

Extended system, configuring, managing, 5-125

F

Fail-over, policy, 1-22

Fault list

consulting, 4-33

monitoring, 4-15

viewing, 4-35

Fault status, checking, 4-47

FDA 1300 disk rack, 1-17

FDA 2300 FC disk rack, 1-17

FDD, 1-14

Firmware information, 4-17

Force power off, domain, 3-21

Front door, opening, 1-20

FRU information, 4-16

Functional status, CSS hardware, 4-4

functional status, domain, 3-29

G

Getting to know, server, 1-7

H

I

Hardware

connections, 3-43

excluding, 4-23, 4-47

exclusion, 3-43

including, 4-23, 4-24

Hardware availability, checking, 4-46

Hardware components, locking / unlocking, 5-66

Hardware connections, checking, 4-47

Hardware monitor, CSS module power, 4-19

Hardware resources

checklist, 5-126

domain, 3-35

HBA, WWN, 5-64

Highlighting, documentation, xv

Histories

checking, 4-47

creating a user history, 5-157

deleting, 5-159

editing parameters, 5-158

History

archiving, 4-38

viewing, online, 4-36

History / archive, viewing, offline, 4-40

History file, deleting, manually, 4-40

History files

archiving, 4-36 deleting, 4-36

managing, 4-31 viewing, 4-31

HMMIO, 5-52

Identity

checklist, 5-126

copying, 5-54

creating, 5-50

deleting, 5-54 editing, 5-54

managing, 5-50

Illegal characters, xx

Incident

investigating, 4-42 what to do, 4-42, 4-46

Incidents

dealing with, 3-43

domain, 3-42

Include / exclude, monitoring, 4-15

Including

clocks, 4-27

hardware, 4-23, 4-24

sidebands, 4-27

SPS, 4-27

XSP cables, 4-27

Indicators

fault status, 4-15, 4-16 failure status, 4-15, 4-16

functional status, 4-8, 4-15

power status, 4-18

presence status, 4-6, 4-15

temperature status, 4-20

IO memory space, 5-52

IOB, 1-13

IOC

jumper status, 4-21

PCI slot status, 4-22

IOL, 1-13

iSM, 5-5

K

Keyboard, 1-15

Keys, registry, xxi

KVM switch, 1-16

L

Laser safety, xix

LEDs, PMB, 4-50

Licensing number, 5-52

Linux, system users, 5-4

Linux domain, remote access, Web, 2-18

Linux Redhat, remote access, enterprise LAN, 2-16

Linux SuSE domain, remote access, enterprise LAN,

2-17

Locking, hardware components, 5-66

Locking / Unlocking, hardware elements, 5-67

Locking hardware, scheme, 5-33

LUN, creating, 5-5

LUN list, updating, 5-56

LUN properties, modifying, 4-49

LUNs, 5-55, 5-57

creating, 5-60

deleting, 5-61

editing, 5-62

local, 5-60

renaming, 5-63

scheme, 5-33

updating lists, 5-59

M

Machine check halt, 5-52

MAESTRO version, checking, 4-48

Managing

domain configuration schemes, 5-33

domain schemes, 5-50

domains, 3-2

Memory boards, 1-13

MFL, firmware information, 4-17

Microsoft Windows, system users, 5-4

Mirroring, PAP unit, 1-22

Modem, 1-19

Modifying, customer information, 5-19

Modifying, LUN properties, 4-49

Monitor, 1-15

Monitoring

failure status, 4-15, 4-16

fan status, 4-21

fault list, 4-15 fault status, 4-15, 4-16

firmware information, 4-17

FRU information, 4-16

functional status, 4-15

Hardware Search engine, 4-10

hardware status, 4-15 include / exclude, 4-15

jumper status, 4-21

PAM Tree, 4-5

PCI slot status, 4-22

power status, 4-18

presence status, 4-15

server, 4-1, 4-2

Status pane, 4-3

temperature status, 4-20

thermal zones, 4-17

Monothreading mode, 5-52

Mother boards, 1-13

Mouse, 1-15

Multithreading mode, 5-52

N

Notices

electrical safety, xviii

laser safety, xix

safety, xviii

NPort Server, 1-19

NVRAM, 5-55, 5-57

NVRAM variables

clearing, 5-56 loading, 5-56 managing, 5-56 saving, 5-56

P

PAM

connection, 2-2

customizing, 5-133

details pane, 2-6

event messaging, 5-133

simultaneous connection, 2-4

software package, 1-22

Index X-3

status pane, 2-6, 4-3

toolbar, 2-8

tree pane, 4-5

user information, 4-12

user interface, 2-5

writing rules, xx

PAM settings, customizing, 5-22

PAM software

acivating a version, 5-24

back up / restore, 5-26

deploying a release, 5-23

monitoring, 4-2

PAM tree pane, 2-7

PAM version, checking, 4-48

PAM version information, viewing, 4-13

PAP application, rebooting, 3-43, 4-48

PAP unit, 1-14

CD-ROM drive, 1-14 disks, 1-14

Ethernet ports, 1-14

FDD, 1-14

mirroring, 1-22

serial ports, 1-14

PAP users, setting up, 5-17

Partitioning, 5-29

Peripheral drawer, 1-13

PHPB, 1-13

PMB, 1-13

checking, 4-49

code wheels, 4-50

firmware information, 4-17

rebooting, 3-43

resetting, 4-49 testing, 4-49

Power, CSS module, 4-19

Power cables, 1-14, 1-15, 1-16, 1-17, 1-18

Power down, server domain, 2-10, 2-11

Power logs, domain, 3-31

Power off, domain, 3-18

Power on, domain, 3-14

Power sequences, domain, 3-32

Power status, checking, 4-47

Power-up

server domain, 2-10, 2-11

system domains, 2-12, 2-15

Powering ON / OFF, domains, 4-48

Preface, documentation, iii

Processors, 1-13

Q

QBBs, 1-13

R

Rebooting, PAP application, 4-48

Related publications, documentation, xv

Remote access

Enterprise LAN, 2-16

Linux Redhat Domain, 2-16

Linux SuSE domain, 2-17

Windows domain, 2-16

Web, 2-18

Linux domain, 2-18

Windows domain, 2-18

Request logs, domain, 3-34

X-4 User's Guide

Reset, domain, 3-25

Resetting, PMB, 4-49

Resources, server, 1-22

Restoring, PAM software, 5-26

S

Safety, notices, xviii

SAN, 5-57

scheme, 5-33

SAN LUN lists, updating, 5-59

Scheme

assess requirements, 5-33

checklist, 5-126

copying, 5-49

creating, 5-33

deleting, 5-49

editing, 5-48

identity, 5-33

loading, 3-8

locking hardware, 5-33

LUNs, 5-33

managing, 3-5, 5-33

Pre-requisites, 5-33

renaming, 5-49

SAN, 5-33 steps, 5-33

viewing, 3-6

WWN, 5-33

Search, hardware, 4-10

Serial ports, 1-13, 1-14

Server

See also system

domain, 2-10, 2-11

getting to know, 1-7

monitoring, 4-1, 4-2

partitioning, 5-29

resources, 1-22

Server components

accessing, 1-20

CD-ROM drive, 1-14

console, 1-15

core unit, 1-13

CSS module, 1-13

DIMMs, 1-13

Ethernet hub, 1-19

Ethernet ports, 1-13, 1-14

FDA 1300 FC, 1-17

FDA 2300 FC, 1-17

FDD, 1-14

internal peripheral drawer, 1-13

IOB, 1-13

IOL, 1-13

keyboard, 1-15

KVM switch, 1-16

memory boards, 1-13

modem, 1-19

monitor, 1-15

mother boards, 1-13

mouse, 1-15

NPort Server, 1-19

PAP unit, 1-14

PAP unit disks, 1-14

PHPB, 1-13

PMB, 1-13

power cables, 1-14, 1-15, 1-16, 1-17, 1-18

processors, 1-13

QBBs, 1-13 serial ports, 1-13, 1-14

USB ports, 1-13

VGA port, 1-13

Server status, checking, 2-6

Setting up

PAP users, 5-17

system users, 5-4

Severity, event message, 4-32

Snapshot, saving the current configuration, 3-11

SNMP settings, checking, 4-48

Specifications

NovaScale 5085 Servers, A-2

NovaScale 5165 Server, A-4

NovaScale 5245 Server, A-6

NovaScale 5325 Server, A-8

system, A-1

Status

CSS module, 2-7, 4-4

event message, 4-4

exclude / include, 4-15 failure indicators, 4-15, 4-16

fans, 4-21

fault indicators, 4-15, 4-16

functional, 4-7, 4-8

functional indicators, 4-15 hardware information, 4-15

IOC jumper, 4-21

PCI slots, 4-22

power, 4-18

presence, 4-5, 4-6

presence indicators, 4-15

temperature indicators, 4-20

Status pane, PAM, 2-6

String lengths, xxi

Subscriptions

advanced filtering criteria, 5-148

channels, 5-140

creating, 5-141

deleting, 5-142

e-mail account, 5-138

e-mail server, 5-136

editing attributes, 5-142

filter, 5-154

filtering, 5-153

history, 5-157

prerequisites, 5-134 setting up, 5-134

standard filtering criteria, 5-145

understanding filters, 5-143

System

See also server

dimensions, A-1

domains, 2-12, 2-15

weight, A-1

System components, DVD/CD-ROM drive, 1-13

System users

Linux, 5-4

Microsoft Windows, 5-4 setting up, 5-4

T

Temperature status, checking, 4-47

Testing, PMB, 4-49

Thermal zone, 4-17

Thresholding, 5-148

Toolbar, PAM, 2-8

Troubleshooting tools, Action Request Package,

creating, 4-51

U

Unlocking, hardware components, 5-66

USB ports, 1-13

User group, PAP, 5-17

User histories, creating, 5-132

User interface, PAM, 2-5

V

VGA port, 1-13

W

Web, server domain

Linux, connecting, 2-20

Windows, connecting, 2-20

Windows domain, remote access

enterprise LAN, 2-16

Web, 2-18

Writing rules

checking, 4-48

illegal characters, xx

string lengths, xxi

WWN

checking, 5-64

HBA, 5-64

SAN, 5-33

updating, 5-64

Index X-5

X-6 User's Guide

Technical publication remarks form

Title : NOVASCALE NovaScale 5xx5 User's Guide

Reference:

ERRORS IN PUBLICATION

86 A1 41EM 06 Date: September 2007

SUGGESTIONS FOR IMPROVEMENT TO PUBLICATION

Your comments will be promptly investigated by qualified technical personnel and action will be taken as required.

If you require a written reply, please include your complete mailing address below.

Date : NAME :

COMPANY :

ADDRESS :

Please give this technical publication remarks form to your BULL representative or mail to:

Bull - Documentation D ept.

1 Rue de Provence

BP 208

38432 ECHIROLLES CEDEX

FRANCE [email protected]

Technical publications ordering form

To order additional publications, please fill in a copy of this form and send it via mail to:

BULL CEDOC

357 AVENUE PATTON

B.P.20845

49008 ANGERS CEDEX 01

FRANCE

Phone:

FAX:

E-Mail:

Reference

_ _ _ _ _ _ _ _ _ [ _ _ ]

Designation

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

_ _ _ _ _ _ _ _ _ [ _ _ ]

[ _ _ ]

: The latest revision will be provided if no revision number is given.

+33 (0) 2 41 73 72 66

+33 (0) 2 41 73 70 66 [email protected]

Qty

Date: NAME:

COMPANY:

ADDRESS:

PHONE:

E-MAIL:

For Bull Subsidiaries:

Identification:

For Bull Affiliated Customers:

Customer Code:

For Bull Internal Customers:

Budgetary Section:

For Others: Please ask your Bull representative.

FAX:

BLANK

BULL CEDOC

357 AVENUE PATTON

B.P.20845

49008 ANGERS CEDEX 01

FRANCE

REFERENCE

86 A1 41EM 06

Utiliser les marques de découpe pour obtenir les étiquettes.

Use the cut marks to get the labels.

NOVASCALE

NovaScale 5xx5

User's Guide

86 A1 41EM 06

NOVASCALE

NovaScale 5xx5

User's Guide

86 A1 41EM 06

NOVASCALE

NovaScale 5xx5

User's Guide

86 A1 41EM 06

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project