User Guide

6641-22310

WeOS

RedFox Industrial

S E R I E S

Industrial Routing Switch

www.westermo.com

Software tools

Related software tools are available in the folder software tools under technical support on the Westermo website.

License Information

This device contains public available software which is under the GPL license.

For more information see legal.pdf included with all firmware releases.

This product includes software developed by the OpenSSL Project for use in the

OpenSSL Toolkit. http://www.openssl.org

Legal information

The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice.

Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.

More information about Westermo can be found at the following Internet address: http://www.westermo.com

2 6641-22310

Safety

!

Before installation:

Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit.

This unit should only be installed by qualified personnel.

This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only.

The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.

This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section).

Before powering-up, a protective earthing conductor must be connected to the protective earthing terminal and have a cross-sectional area of at least 1.5 mm².

!

!

Before mounting, using or removing this unit:

Prevent access to hazardous voltage by disconnecting the unit from power supply.

Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply.

Class 1 Laser Product

Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations.

Care recommendations

Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations.

This unit must not be operating with removed covers or lids.

Do not attempt to disassemble the unit. There are no user serviceable parts inside.

Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards.

Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.

Do not paint the unit. Paint can clog the unit and prevent proper operation.

Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels.

Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged.

If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support.

Fibre connectors are supplied with plugs to avoid contamination inside the optical port.

As soon as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, the plug should be applied.

Warning:

When this unit is operated at an ambient temperature above 60 °C, the External Surface of Equipment may exceed Touch Temperature Limit according to UL/IEC/EN 60950-1.

To reduce the risk of fire, use on No. 26 AWG or larger telecommunication line cord.

6641-22310 3

Note. Fibre Optic Handling

Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt.

If the fibre will be disconnected from the unit the protective hood on the transmitter/ receiver must be connected. The protective hood must be kept on during transportation.

The fibre optic cable must also be handle the same way.

If these recommendations are not followed, the warranty might be jeopardized.

Cleaning of the optical connectors

In the event of contamination, the optical connectors should only be cleaned by the use of recommended cleaning fluids and correct cleaning equipment.

Recommended cleaning fluids:

• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol

• Hexane

• Naphtha

Maintenance

No maintenance is required, as long as the unit is used as intended within the specified conditions.

4 6641-22310

Agency approvals and standards compliance

Art.no

3641-4000

3641-4110

3641-4200

3641-4210

3641-4300

3641-4305

3641-4310

3641-4315

3641-4320

Denomination

RFI-219-T3G

RFI-211-T3G

RFI-215-F4G-T3G

RFI-207-F4G-T3G

RFI-219-F4G-T7G

RFI-119-F4G-T7G

RFI.-211-F4G-T7G

RFI-111-F4G-T7G

RFI-219-F4G-T7G-F8

Type

EMC

Safety

Marine

Approval/compliance

EN 50121-4, Railway applications – Electromagnetic compatibility – Emission and immunity of the signalling and telecommunications apparatus

EN 55022, Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement

EN 55024, Information technology equipment – Immunity characteristics Limits and methods of measurement

EN 61000-6-1, Electromagnetic compatibility – Immunity for residential environments

EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments

EN 61000-6-3, Electromagnetic compatibiliy – Emission standards for residential, commercial and light-industrial environments

EN 61000-6-4, Electromagnetic compatibility – Emission for industrial environments

FCC Part 15 Class A

UL/IEC/EN 60950-1, IT equipment

DNV Standard for Certification no. 2.4

FCC Part 15.105

Notice:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EN 55022 Notice: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

6641-22310 5

Safety control drawing

1

2

3

4

IO / Status +

IO / Status –

IO / Digital In +

IO / Digital In –

Input / Output values

U in

= 60 VDC max

I in

= 80 mA max

U in

= 60 VDC max

I in

= 2.9 mA max

3

4

1

2

M5 threaded hole for PE connection

Input/output values

5

6

3

4

7

1

2

In/Out / BI_DA+

In/Out / BI_DA–

In/Out / BI_DB+

In/Out / BI_DC+

In/Out / BI_DC–

In/Out / BI_DB–

In/Out / BI_DD+

Per port:

U = ± 1 V (4V/us)

I = ± 20 mA

Data rate:

10/100/1000 Mbit/s

8 In/Out / BI_DD–

Shield PE

Galvanically isolated via signal transformers and capacitively isolated to GND/PE through a 2kV

1000pF capacitor.

See user manual for proven transient protection.

Output values

1

2

3

Out / VBUS

In/Out / D–

In/Out / D+

4 GND

Shield PE

I

U out

= 5 VDC max out

= 500 mA max

Input values

3

4

1

2

In / +DC1

In / +DC2

In / COM

In / COM

Degree of protection:

Ambient temperature:

Installation spacing:

U in

I in

P

In

= (16 – 60) VDC

= 2.0 A @ 16 VDC

= 31.5 W @ 16 VDC

IP 40

–40 °C to +70 °C

Minimum 25 mm above/below

Minimum 10 mm left/right

1

2

3

4

5

Input/output values

In/Vbus

In/Out D-

In/Out D+

Not connected

GND

U = 5V VDC max

I = 100 mA max

6 6641-22310

Safety control drawing

3

7

2

6

4

8

1

5

Position Direction* / description

1 In/Out / TD+

2 In/Out / TD–

5

6

3

4

7

In/Out / RD+

Not connected

Not connected

In/Out / RD–

Not connected

Input/output values

Per port:

U = ± 1 V (4V/us)

I = ± 20 mA

Data rate:

10/100 Mbit/s

8 Not connected

Shield PE

Galvanically isolated via signal transformers and capacitively isolated to GND/PE through a 2kV 1000pF capacitor.

See user manual for proven transient protection.

Position Direction* / description Input/output values

Rx In / Receive port

Tx Out / Transmit port

Max 5 dBm

Position Direction* / description Input/output values

1 In/Out / BI_DA+

4

5

2

3

6

7

8

In/Out / BI_DA–

In/Out / BI_DB+

In/Out / BI_DC+

In/Out / BI_DC–

In/Out / BI_DB–

In/Out / BI_DD+

In/Out / BI_DD–

Per port:

U = ± 1 V (4V/us)

I = ± 20 mA

Data rate:

100/1000 Mbit/s

Shield PE

Galvanically isolated via signal transformers and capacitively isolated to GND/PE through a 2kV 1000pF capacitor.

See user manual for proven transient protection.

* Direction relative this unit!

6641-22310 7

Declaration of Conformity

Westermo Teleindustri AB

Declaration of conformity

The manufacturer Westermo Teleindustri AB

SE-640 40 Stora Sundby, Sweden

Herewith declares that the product(s)

Type of product

Industrial Ethernet Switch

Models

1

RFI-x19-T3G-y, RFI-x11-T3G-y, RFI-x15-F4G-T3G-y,

RFI-x07-F4G-T3G-y, RFI-x19-F4G-T7G-y,

RFI-x11-F4G-T7G-y, RFI-x19-F4G-T7G-F8-y is in conformity with the following EC directive(s).

No Short name

2004/108/EC Electromagnetic Compatibility (EMC)

2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)

References of standards applied for this EC declaration of conformity.

No

EN 50121-4

EN 55022

EN 55024

EN 61000-6-1

EN 61000-6-2

EN 61000-6-3

Title

Railway applications – Electromagnetic compatibility – Emission and immunity of the signalling and telecommunications apparatus

Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement

Information technology equipment – Immunity characteristics

Limits and methods of measurement

Electromagnetic compatibility – Immunity for residential environments

Electromagnetic compatibility – Immunity for industrial environments

Electromagnetic compatibility – Emission for residential environments

Issue

2006

2010

2010

2007

2005

+ C1: 2005

2007

+A1:2011

EN 61000-6-4

EN 50581

Electromagnetic compatibility – Emission for industrial environments

Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances

The last two digits of the year in which the CE marking was affixed:

2007

+A1:2011

2012

15

8

Pierre Öberg

Technical Manager

25 th Mars 2015

1

Model Differences: x = 1 or 2 and indicates software version, y = optional and may indicate customer specific models.

Postadress/Postal address

S-640 40 Stora Sundby

Tel.

016-428000

Telefax

016-428001

Postgiro

52 72 79-4

Bankgiro

5671-5550

Org.nr/

Corp. identity number Registered office

556361-2604 Eskilstuna

Sweden Int+46 16428000 Int+46 16428001

6641-22310

Type tests and environmental conditions

Phenomena

ESD

RF field AM modulated IEC 61000-4-3

Fast transient EN 61000-4-4

Surge

RF conducted

Test

EN 61000-4-2

EN 61000-4-5

EN 61000-4-6

EN 61000-4-8

Description

Enclosure contact

Enclosure air

Enclosure

Signal ports

Power ports

Signal ports

Power ports

Signal ports

Power ports

Enclosure Power frequency magnetic field

Pulse magnetic field

Radiated emission

Conducted emission

EN 61000-4-9

CISPR 16-2-3

ANSI C63.4

(FCC part 15)

CISPR 16-2-1

Enclosure

Enclosure

Enclosure

Dielectric strength

Temperature

Humidity

Altitude

Service life

Vibration

EN 60950

EN 60068-2-1

EN 60068-2-2

EN 60068-2-27

IEC 60068-2-6

DC power ports

Telecommunication ports

Signal port to other isolated ports

Power port to other isolated ports

Operating

Storage & Transport

Maximum surface temperature

Operating

Storage & Transport

Operating

Operating

Operating

Shock

Enclosure

IEC 60068-2-27

UL 94

Operating

Aluminium / Zink

Test levels

± 6 kV

± 8 kV

20 V/m 80% AM (1 kHz), 80 – 2700 MHz

± 2 kV

± 2 kV

± 2 kV line to earth, ± 1 kV line to line

± 2 kV line to earth, ± 1 kV line to line

10 V 80% AM (1 kHz), 0.15 – 80 MHz

10 V 80% AM (1 kHz), 0.15 – 80 MHz

300 A/m 0, 16.7, 50, 60 Hz

300 A/m

Class B

Class B, 30 – 6500 MHz

Class B

1.5 kVrms 50 Hz 1 min

1.5 kVrms 50 Hz 1 min

–40 to +70ºC (all models)

–40 to +85ºC (all models)

135 °C (temperature class T4)

5 to 95% relative humidity

5 to 95% relative humidity

2 000 m / 70 kPa

10 years

7.5 mm, 5 – 8 Hz

2 g, 8 – 500 Hz

(Wall-mounted or DIN-rail mounted using TH

35-15 according to EN 60175)

15 g, 11 ms

(Wall-mounter or DIN-rail mounted using TH

35-15 according to EN 60175)

Flammability class V-0 (all models)

6641-22310 9

Description

The RedFox Industrial includes a collection of high performance industrial Ethernet switches with enhanced routing functionality designed to build cost effective, secure and reliable networks. The product range offers a number of Ethernet interface combinations, which gives you the ability to select the perfect routing switch for your application providing optimum functionality at the best value.

Advanced routing functions and firewall settings allow the RedFox to segregate networks and ensure that mission critical industrial networks are protected. The RedFox is also able to provide secure remote access to these networks across insecure connections by acting as a VPN endpoint.

RedFox Industrial models

Westermo article number

3641-4100

Denomination

RFI-219-T3G

3641-4110

3641-4200

3641-4210

3641-4300

3641-4305

3641-4310

3641-4315

3641-4320

Description

RFI-211-T3G

RFI-215-F4G-T3G

RFI-207-F4G-T3G

RFI-219-F4G-T7G

RFI-119-F4G-T7G

RFI-211-F4G-T7G

RFI-111-F4G-T7G

RFI-219-F4G-T7G-F8

3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

16 x 10/100 Mbit/s, Ethernet TX, RJ-45

3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

8 x 10/100 Mbit/s, Ethernet TX, RJ-45

3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

8 x 10/100 Mbit/s, Ethernet TX, RJ-45

4 x 100/1000 Mbit/s, pluggable connections tranceivers supported, Ethernet FX or TX SFP

3 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45.

4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

8 x 10/100 Mbit/s, Ethernet TX, RJ-45

7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

8 x 10/100 Mbit/s, Ethernet TX, RJ-45

7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

7 x 10/100/1000 Mbit/s, Ethernet TX, RJ-45

4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

8 x 100 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP

10 6641-22310

Housing

Description

Depending on RedFox model, the size of the enclosure may vary. There are two sizes available, a two-slot housing and a three-slot housing.

Regardless of RedFox model, the slot on the far left will always be occupied by the power and CPU interface. Other slots vary depending on RedFox model.

The back end holds a casted DIN-clip for stable mounting on a DIN-rail. Direct wallmount is also possible using the four brackets in each corner. The back end also holds the earth connection. For detailed ground connection information see section on Earth

Connection.

2 and 3 slot enclosure

The slot on the left will always be occupied by the power and CPU. Other slots may vary depending on RedFox model.

Specification

2 slot enclosure

Dimension W x H x D 134 x 105 x 122 mm

(without connectors)

Weight 1.5 kg

Number of slots

Degree of protection

2

IP40 according to EN 60529

Cooling

Mounting

Convection

Horizontal on 35 mm DIN-rail or wall-mounted

3 slot enclosure

175 x 105 x 122 mm

(without connectors)

2.2 kg

3

IP40 according to EN 60529

Convection

Horizontal on 35 mm DIN-rail or wall-mounted

6641-22310 11

Power and CPU module

Description

Regardless of RedFox model, all units will be delivered with the power and CPU interface in the slot on the far left. The power and CPU module holds a power board and a CPU board. The isolated power supply has redundant power inputs and allows for a wide operating voltage range (see interface specification). The digital IO-port can be used for monitoring the unit (see Westermo OS management guide).

The CPU module holds several interfaces. Three RJ-45 connectors with support for

Ethernet 1000BaseTX, a USB port for easy save/load of system configuration and a console port. The console connector is a micro USB cable that connects to a FTDI

FT232R USB to serial converter internally. For drivers please see www.ftdichip.com and download the appropriate VCP driver.

For detailed information on LED indicators, see section on LED indicators Power/CPU.

Power and CPU

… Redundant power supply and alarm function

… Wide operating voltage range (16 VDC to 60 VDC)

… Digital IO for monitoring

… Console port for management using CLI

… USB port for easy save and load system configuration

… 3 x RJ-45 Ethernet 1000BaseTX connectors

… Status LED's

12 6641-22310

Interface specifications

Power and CPU

Rated voltage

Operating voltage

Rated frequency

Polarity

Redundant power input

Isolation to

Connection

Connector size

Shielded cable

20 to 48 VDC

16 to 60 VDC

DC

Reverse polarity protected

Yes

All other

Detachable screw terminal

0.2 – 2.5 mm 2 (AWG 24 – 12)

Not required

6641-22310 13

Power

Rated voltage

Operating voltage

Rated current RFI-111-F4G-T7G

RFI-119-F4G-T7G

RFI-207-F4G-T3G

RFI-211-F4G-T7G

RFI-211-T3G

RFI-215-F4G-T3G

RFI-219-F4G-T7G

RFI-219-F4G-T7G-F8

RFI-219-T3G

Inrush current

Startup current**

Rated frequency

Polarity

Redundant power input

Isolation to

Connection

Connector size

Shielded cable

* With 500mA USB load

** External supply current capability for proper start-up

20 to 48 VDC

16 to 60 VDC

0.87 (1.06*) A @ 20 VDC

0.35 (0.43*) A @ 48 VDC

0.93 (1.12*) A @ 20 VDC

0.38 (0.45*) A @ 48 VDC

0.55 (0.72*) A @ 20 VDC

0.23 (0.29*) A @ 48 VDC

0.87 (1.06*) A @ 20 VDC

0.35 (0.43*) A @ 48 VDC

0.43 (0.60*) A @ 20 VDC

0.19 (0.25*) A @ 48 VDC

0.63 (0.82*) A @ 20 VDC

0.26 (0.33*) A @ 48 VDC

0.93 (1.12*) A @ 20 VDC

0.38 (0.45*) A @ 48 VDC

1.30 (1.47*) A @ 20 VDC

0.52 (0.58*) A @ 48 VDC

0.63 (0.79*) A @ 20 VDC

0.26 (0.33*) A @ 48 VDC

40 mA2s @ 20 VDC

257 mA2s @ 60 VDC

2x Rated current

DC

Reverse polarity protected

Yes

All other

Detachable

0.2 - 2.5 mm2 (AWG 24 - 12)

Not required

14 6641-22310

Connection to console port

The console port can be used to connect to the CLI

(Command Line Interface). The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally. For drivers please see www.

ftdichip.com and download the appropriate VCP driver.

Console

Electrical specification

Data rate

Circuit type

Maximum supply current

Isolation to

Galvanic connection to

Connection

USB 2.0 device interface

High speed 480mbit/s

SE LV

100 mA

All other except USB

USB

USB Micro-B connector in device mode

6641-22310 15

USB

Electrical specification

Data rate

Circuit type

Maximum supply current

Isolation to

Connection

Conductive housing

IO / Relay output

Connect resistance

Isolation to

Connection

Connector size

Maximum voltage/current

IO / Digital input

Voltage levels

USB 2.0 host interface

High speed 480mbit/s

SELV

500 mA

All other except Console

USB receptacle connector type A

Yes

30 W

All other

Detachable screw terminal

0.2 – 2.5 mm 2 (AWG 24 – 12)

60 VDC / 80 mA

Isolation to

Connection

Connector size

Maximum voltage

Vih > 8V Vil < 5V

Iin = 2.9mA @60V

All other

Detachable screw terminal

0.2 – 2.5 mm 2 (AWG 24 – 12)

60 VDC

Ethernet TX

Electrical specification

Data rate

Duplex

Circuit type

Transmission range

Isolation to

Connection

Shielded cable

IEEE std 802.3. 2005 Edition

10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto

Full or half, manual or auto

TNV-1

Up to 150 m with CAT5e cable or better*

All other

RJ-45 auto MDI/MDI-X

Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails*

Yes

3

Conductive housing

Number of ports

* NOTE! Railway installation close to the rails.

To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth. Refer also to "Safety" section.

16 6641-22310

6641-22310

Position Direction

1 In/Out

2 In/Out

3

4

5

6

In/Out

In/Out

In/Out

In/Out

7

8

Shield

In/Out

In/Out

In/Out

Description

BI_DA+

BI_DA–

BI_DB+

BI_DC+

BI_DC–

BI_DB–

BI_DD+

BI_DD–

Connected to PE

Console

(see more information on page 13)

Position Direction*

1 Out

2

3

4

Shield

In/Out

In/Out

Out

In/Out

* Direction relative this unit.

Description

VBUS

D–

D+

GND

Connected to PE

17

Power connection

3

1

2

4

4-position Product marking

No. 1

No. 2

No. 3

+DC1

+DC2

-COM

Direction

Input

Input

Input

Description

Supply voltage input DC1

Supply voltage input DC2

Common

No. 4 -COM Input Common

Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the

–COM pins on the power input.

I/O connection

4-position Product marking Direction Description

1

2

3

4

No. 1

No. 2

No. 3

No. 4

Status +

Status –

Digital In +

Digital In –

Output

Output

Input

Input

Alarm relay (status) contact

Alarm relay (status) contact

Digital In +

Digital In –

The Status output is a potential free, opto-isolated normally closed solid-state relay.

This can be configured to monitor various alarm events within the Lynx unit, see WeOS Management Guide.

An external load in series with an external voltage source is required for proper functionality.

For voltage/current ratings, see Interface Specification section.

The Digital In is an opto-isolated digital input which can be used to monitor external events.

For voltage/current ratings, see

Interface Specification section:

Lynx

1

2

External

Load

V Status

3

4

+

V Digital In

18 6641-22310

LED indicators Power/CPU

LED

ON

DC1

DC2

FRNT

Status

OFF

Description

Unit has no power.

GREEN All OK, no alarm condition.

RED

BLINK

Alarm condition, or until unit has started up. (Alarm conditions are configurable, see ''WeOS Management Guide'').

Location indicator ("Here I am!").

Activated when connected to IPConfig

Tool, or upon request from Web or CLI.

OFF Unit has no power.

GREEN Power OK on DC1.

RED

OFF

+DC1 input voltage is below operating voltage limit

Unit has no power.

GREEN Power OK on DC2.

RED +DC2 input voltage is below operating voltage limit

OFF FRNT disabled.

GREEN FRNT OK.

RED

BLINK

FRNT Error.

Unit configured as FRNT Focal Point.

RSTP OFF RSTP disabled.

GREEN RSTP enabled.

USR1

BLINK

Copper ports 1-3 OFF

Unit elected as RSTP/STP root switch.

Configurable, see WeOS Management Guide

No link.

GREEN Link established.

GREEN

FLASH

Data traffic indication.

YELLOW Port alarm and no link. Or if FRNT,

RSTP or Link Aggregation mode, port is blocked.

6641-22310 19

Interface modules

8 copper ports

All ports support category 5e cable or better and can handle cable lengths up to 150 m

(492 ft).

Interface specifications

8 copper ports

Electrical specification

Data rate

Duplex

Circuit type

Transmission range

Isolation to

Connection

Shielded cable

Conductive housing

Number of ports

IEEE std 802.3. 2005 Edition

10 Mbit/s or 100 Mbit/s, manual or auto

Full or half, manual or auto

TNV-1

Up to 150 m with CAT5e cable or better*

All other

RJ-45 auto MDI/MDI-X

Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails*

Yes

8

* NOTE! Railway installation close to the rails.

To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth. Refer also to "Safety" section.

20 6641-22310

LED indicators 8 copper ports

LED

Copper ports 1 – 8

Status

OFF

Description

No link.

GREEN Link established.

GREEN FLASH Data traffic indication.

YELLOW Port alarm and no link. Or if FRNT, RSTP or Link

Aggregation mode, port is blocked.

ON

DC1

DC2

1

Position Direction*

1 In/Out

2 In/Out

3

4

In/Out

Description

2

TD+

TD–

RD+

Not connected

5 – Not connected

6 In/Out RD–

7

8

Shield

+DC1

+DC2

Not connected

Not connected

COM

* Direction relative this unit.

FRNT

RSTP

Connected to PE

VPN

1

2

3

4

2

6

1

5

3

7

4

8

4

8

3

7

2

6

1

5

6641-22310 21

F4G, 4 SFP slots

The F4G interface has four SFP slots supporting Ethernet 10/100/1000BaseFX/X.

Each slot can hold one SFP transceiver for copper or fibre cable. For supported transceivers see SFP transceivers user guide (art no. 6100-0000) available at www.

westermo.com.

Interface specifications

F4G

Optical/Electrical specification

Data rate

Duplex

Transmission range

Connection

Number of ports

IEEE std 802.3. 2005 Edition

10, 100 or 1000 Mbit/s*

Full or half, manual or auto

Depending on transceiver

SFP slot holding fibre transceiver or copper transceiver

4

* 100 Mbit/s or 1000 Mbit/s transceiver supported.

F8, 8 SFP slots

The F8 interface has eight SFP slots supporting Ethernet 10/100BaseFX.

Each slot can hold one SFP transceiver for copper or fibre cable. For supported transceivers see SFP transceivers user guide (art no. 6100-0000) available at www.

westermo.com.

Interface specifications

F8

Optical/Electrical specification

Data rate

Duplex

Transmission range

Connection

Number of ports

IEEE std 802.3. 2005 Edition

10 or 1000 Mbit/s*

Full or half, manual or auto

Depending on transceiver

SFP slot holding fibre transceiver or copper transceiver

8

* 10 Mbit/s or 100 Mbit/s transceiver supported.

22 6641-22310

LED indicators F4G

LED

Fibre ports 1 – 4

Status

OFF

Description

No link.

GREEN Link established.

GREEN FLASH Data traffic indication.

YELLOW Port alarm and no link. Or if FRNT, RSTP or Link

Aggregation mode, port is blocked.

Position Direction*

Rx In

Tx Out

* Direction relative this unit.

Description

Receive port

DC2

Transmit port

ON

1

2

1

2

+DC1

+DC2

CONSOLE

COM

COM

FRNT

RSTP

VPN

3

4

3

7

2

6

1

5

4

8

2

6

1

5

3

7

4

8

6641-22310 23

LED indicators F8

LED

Fibre ports 1 – 8

Status

OFF

Description

No link.

GREEN Link established.

GREEN FLASH Data traffic indication.

YELLOW Port alarm and no link. Or if FRNT, RSTP or Link

Aggregation mode, port is blocked.

Position Direction*

Rx In

Tx Out

* Direction relative this unit.

Description

Receive port

Transmit port

2

6

1

5

3

7

4

8

24 6641-22310

F4G-T4G, 4 SFP slots and 4 Gbit copper ports

The F4G-T4G interface has four SFP slots supporting Ethernet BaseFX/X and four RJ-45 connectors supporting Ethernet 10/100/1000BaseTX/T. Each SFP slot can hold one SFP transceiver for copper or fibre cable. Fibre transceiver distances range from 550 m (0.34 mi) to 120 km (74,6 mi).

For supported transceivers see section on SFP transceivers.

All ports support category 5e cable or better and can handle cable lengths up to 150 m

(492 ft).

Interface specifications

F4G-T4G

Fixed copper ports (RJ-45)

Electrical specification

Data rate

Duplex

Circuit type

Transmisson range

Isolation to

Connection

Shielded cable

IEEE std 802.3. 2005 Edition

10, 100 or 1000 Mbit/s

Full or half, manual or auto

TNV-1

Up to 150 m with CAT5e cable or better*

All other

RJ-45 auto MDI/MDI-X

Not required, except when installed in Railway applications assignalling and telecommunications apparatus and located close to rails*

Yes

4

Conductive housing

Number of ports

* NOTE! Railway installation close to the rails.

To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth. Refer also to "Safety" section.

SFP ports

Optical/Electrical specification

Data rate

Duplex

Transmission range

Connection

Number of ports

IEEE std 802.3. 2005 Edition

10, 100 or 1000 Mbit/s*

Full or half, manual or auto

Depending on transceiver

SFP slot holding fibre transceiver or copper transceiver

4

* 100 Mbit/s or 1000 Mbit/s transceiver supported.

6641-22310 25

LED indicators F4G-T4G

LED

Copper ports 1 – 4

Fibre ports 5 – 8

Status

OFF

Description

No link.

GREEN Link established.

GREEN FLASH Data traffic indication.

YELLOW Port alarm and no link. Or if FRNT, RSTP or Link

Aggregation mode, port is blocked.

DC1

DC2

Position Direction*

ON

1 In/Out

1 2 In/Out

3 In/Out

In/Out

2

4

5

6

In/Out

In/Out

7

8

In/Out

In/Out

Shield In/Out

+DC1

+DC2

* Direction relative this unit

COM

COM

FRNT Position Direction*

RSTP Rx In

VPN Tx Out

* Direction relative this unit.

Description

BI_DA+

BI_DA–

1

BI_DB+

BI_DC+

2

BI_DC–

BI_DB–

BI_DD+

BI_DD–

Receive port

Transmit port

4

8

3

7

2

6

1

5

3

7

2

6

4

8

1

5

26 6641-22310

SFP Transceivers

See SFP Transceivers User Guide 6100-0000 for supported SFP transceivers.

Note: The unit supports Westermo labelled transceivers only.

Deviations

With copper transceiver 1100-0148 the specified operating temperature on the RFI-series is 0 to 50 ºC.

FRNT reconfiguration times can not be guaranteed with copper transceivers.

User Guide

6100-0000

ESD Protection estermo

Teleindustri

6641-22310 27

Mounting

Mounting, 35 mm DIN-rail

The unit can be mounted on a 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet, or similar.

Snap on mounting, see figure.

Note! For proper vibration and chock performance

Westermo recommends standard top-hat DIN-rail TH 35-15 according to EN 60715.

Removal

Press down the support at the back of the unit using a screwdriver. See figure.

CLICK!

Wall mounting

This unit can also be wall-mounted, see figure.

DC1

DC2

ON

1

2

+DC1

+DC2

CONSOLE

COM

COM

FRNT

RSTP

VPN

3

4

1

2

4

8

3

7

2

6

1

5

Earth connection

For correct function the ground connection on the unit needs to be properly connected to a solid ground.

See figure.

Cooling

This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above

/below and 10 mm (0.4 inches) left /right the unit.

Spacing is recommended for the use of unit in full operating temperature range and service life. See figure.

28

DC1

DC2

ON

1

2

+DC1

+DC2

CONSOLE

COM

COM

FRNT

RSTP

VPN

1

2

3

4

4

8

3

7

2

6

1

5

DC1

DC2

ON

1

2

+DC2

COM

COM

FRNT

RSTP

VPN

3

4

1

2

25 mm

DC1

DC2

ON

1

2

+DC1

+DC2

CONSOLE

COM

COM

FRNT

RSTP

VPN

25 mm

1

2

3

4

4

8

3

7

2

6

1

5

6641-22310

Getting Started

This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the unit.

• WeConfig

WeConfig is a Network configuration management tool (NCM) made for commissioning and maintenance of components in a network.

• Web

Configuration of the unit using the web browser.

• CLI

Configuration of the unit via the Command Line Interface.

If the computer is located in the same subnet as the switch you can easily use a web browser to configure the unit. Within the web you can configure most of the available functions.

For advanced network settings and more diagnostic information, please use the CLI.

Detailed documentation is available in the chapter The Command Line Management

Tool in the WeOS management guide.

Factory default IP address: 192.168.2.200 (and DHCP client)

Netmask: 255.255.255.0

Gateway: Disabled

Note! If you are not sure about the subnet – consult your network administrator.

Configuration

Configure the unit via Webbrowser

The unit can easily be configured via a Web browser.

Open the link http://192.168.2.200 in your web browser, and you will be prompted with a Login screen, where the default settings for Username and Password are:

Username: admin

Password: westermo

Once you have logged in, you can use the extensive integrated help function describing all configuration options. Two common task when configuring a new switch is to assign appropriate IP settings, and to change the password of the admin account.

The password can be up to 64 characters long, and should consist of printable ASCII characters (ASCII 33-126); 'Space' is not a valid password character.

6641-22310 29

Referring documents

Type

Management Guide

Description

Westermo OS management guide

Document number

6101-3201

Cable factory reset on RedFox Industrial

It is possible to set the unit to factory default settings by using a standard (straight)

Ethernet RJ-45 cable.

1. Power off the switch and disconnect all Ethernet cables (including copper and fibre).

2. Connect an Ethernet cable between Ethernet port 1/1 and Ethernet port 1/2 (that is, connect Ethernet ports 1 and 2 on in the leftmost slot by an Ethernet cable).

The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or switch. Use a straight cable - not a cross-over cables - when connecting the ports.

3. Power on the unit.

4. Wait for the unit to start up. Control that the ON LED is flashing red.

The ON LED flashing indicates that the unit is now ready to be reset to factory default. You now have the choice to go ahead with the factory reset, or to skip factory reset and boot as normal.

• Go ahead with factory reset: Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables. The ON LED will stop flashing. This initiates the factory reset process, and the unit will restart with factory default settings.

• Note! Do not power off the unit while the factory reset process is in progress. Skip the factory reset: To skip the factory reset process, just wait for approximately 30 seconds (after the ON LED starts flashing RED) without unplugging the Ethernet cable. The switch will conduct a normal boot with the existing settings.

30 6641-22310

6641-22310 31

Westermo • SE-640 40 Stora Sundby, Sweden

Tel +46 16 42 80 00 Fax +46 16 42 80 01

E-mail: [email protected] www.westermo.com

Sales Units

Westermo Data Communications

China [email protected] www.cn.westermo.com

France [email protected] www.westermo.fr

Germany [email protected] www.westermo.de

North America [email protected] www.westermo.com

Singapore [email protected] www.westermo.com

Sweden [email protected] www.westermo.se

United Kingdom [email protected] www.westermo.co.uk

Other Offices

For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code

REV. F 6641-22310 2015-09 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group Company