PHANTOM Series 100% Recessed Emergency Lighting

PHANTOM Series 100% Recessed Emergency Lighting
Type:
Project/Location:
Contractor:
PHANTOM™ Series
CLOSED
FEATURES
Supply and install Lumacell® Phantom™ Series. The unit shall be designed to be concealed
in walls or ceilings with a cavity, including T-bar suspended ceilings. Bar hanger brackets
shall be provided with the self-powered unit. The unit equipment shall come standard with
a metal back box containing the batteries, the lamp assembly and a charging circuitry. The
back box shall be constructed of heavy-duty galvanized steel. The unit components: battery
assembly, charger circuitry and lamp assembly shall have a modular design and come
standard with quick connect plugs for easy installation in the back box.
The unit equipment shall be completely concealed in the wall or ceiling during normal power
conditions. Upon a power failure the unit will expose the emergency heads by rotating its
door 180° and then power the lamps. At the restoration of the AC power or at the end of
the battery discharge, the lamps will turn off and the unit will retract the heads in the wall
(ceiling) by rotating the door by 180°. Under normal conditions, the only visible parts of
the unit shall be the flat door and trim plate, coated with a high-quality off-white finish that
can be customized on site with paint or other suitable wall covering. The light source shall
be 12V MR16 halogen lamps of specified wattage and light output. The unit shall supply
the rated load for a minimum of 30 minutes or until the battery is discharged to 87 ½%
of its nominal voltage (whichever duration is longer). The charger circuitry shall utilize a
micro-controller IC that samples the battery in relation to the ambient temperature, state
of charge, and input voltage fluctuations. The charger shall be current limited, temperature
compensated, short-circuit proof, and reverse-polarity protected. The circuit will charge in
accordance with the CSA C22.2 – 141 requirements. The unit shall be furnished with a
recessed, illuminated push button serving as test switch and status indicator light.
When specified, the unit shall come complete with the Lumacell® of auto-test microcontroller circuitry that will ensure the equipment readiness and reliability by continuously
monitoring every critical function of the unit. If a problem occurs, the pilot light located on
the front of the unit, will change color from green to red and will flash indicating a fault.
A detailed diagnostic legend shall be available on the door back side and shall provide fault
identification (battery, charger circuitry, lamps) for the maintenance personnel.
The auto-test shall simulate a power loss for one minute monthly, 10 minutes every sixth
months, and a full 30-minute test every 12 months.
.
The equipment shall be Lumacell® model:
and closes or upon power back-on at the end of battery discharge
•Input: Standard AC input 120/347VAC, 0.25/0.09 As;
optional 120/277VAC
•Battery: maintenance-free, sealed Lead-Acid battery,
with a 10-year design life
•Charger: micro-controller driven, temperature compensated,
high-precision, fast recharge
•Back-box (self-powered unit): made of heavy-duty, galvanized steel
•Remote fixture: version available in 12VDC or 24VDC;
no back box, no AC wires are required
•Certification: CSA C22.2 No.141
DIMENSIONS
Dimensions are approximate and subject to change.
91/8” [23.2 cm]
77/8” [20.0 cm]
237/8” [60.6 cm]
7” [17.8 cm]
33/8” [8.6 cm]
REPLACEMENT LAMPS: MR16 TYPE
POWER CONSUMPTION
PH75
120/347 0.25/0.09
VAC
A
PH150
Model No.:
TYPICAL SPECIFICATIONS
•Fully automatic operation: the unit door opens upon loss of AC power
AC ASPECS
Date:
100% Recessed
Emergency Lighting
OPENED
MODEL
Prepared By:
WATTAGE CAPACITY
30MIN
2H00
4H00
75
1H00 1H30
40
30
24
15
150
80
60
48
30
IN THE SAME FAMILY:
- Phantom™ Series Remote Fixtures
p. 128
MODEL
VOLTAGE/WATTAGE
580.0080-L
12V-12W
580.0064-L
12V-20W
580.0083-L
12V-35W
580.0076-L
12V-50W
580.0068-L
12V-20W H*
580.0090-L
12V-35W H*
580.0089-L
12V-50W H*
580.0093-L
12V-4W LED
580.0104-L
12V-5W LED
580.0106-L
12V-6W LED
*High-lumen output. See the complete list p. 144 to 146
ORDERING INFORMATION
SERIES
UNIT CAPACITY
PH
75= 12V-75W,
lead-acid
150= 12V-150W,
lead-acid
EXAMPLE: PH15012WAT
94
www.lumacell.com
LAMP WATTAGE
LD7= MR16 LED, 2x 4W
LD9= MR16 LED, 2x 5W
LD10= MR16 LED, 2x 6W
12W= MR16 halogen, 2x 12W
20W= MR16 halogen, 2x 20W
35W= MR16 halogen, 2x 35W
50W= MR16 halogen, 2x 50W
20WH=MR16-IR, 2x 20W high output
35WH= M
R16-IR, 2x 35W, high output
50WH= M
R16-IR, 2x 50W, high output
VOLTAGE
OPTIONS
Blank= 120/347VAC
ZC= 120/277VAC
AT= auto-test*
ATN= auto-test, non-audible*
T3= time delay (15 minutes)
* Minimum lamp load required:
20% of unit capacity.