PCW PC Wiring System Series e-con type is newly added!

PC Wiring System Position Detection Switch Flow Sensor Pressure Control Pressure Sensor Series PCW Simple parallel wiring type Branch unit separates each manufacturer’s 32 point Input/Output (I/O) into 16 point common pin layout. Conversion to a common pin layout, allows connection of the pin to SMC manifold solenoid valves and other manufacturers’ relay terminals without restriction. Power can be supplied to the PLC I/O unit. Compatible branch units are available for each PLC manufacturer’s I/O. Without time delay unlike serial transmission. Easy visual understanding at a glance, offering simple start-up, de-bug and trouble shooting maintenance. Length Measuring/ Counter Branch unit offers commonality Static Electricity Elimination Equipment Reduced-wiring Fieldbus System ded! d a y newl tion s i e typ connec . n o c e- touch bor a l g One es wirin c redu Improved wiring efficiency and ease of operation Alphabetical Index Dedicated cable reduces wiring-equivalent to a serial transmission system. One-touch type connector offers standardized wiring to prevent incorrect connection and vastly improved operational efficiency. 583 A revolutionary new wiring system... Compatible PLC Manufacturers 32 32 inputs inputs 64 outputs OMRON Corporation Mitsubishi Electric Corporation Sharp Corporation KEYENCE CORPORATION 24 VDC Power supply Direct connected branch unit Note) Applicable e-con type PLC manufacturers: OMRON Corporation, Mitsubishi Electric Corporation e-con 16 point branch unit (with cover) e-con 8 point unit (with cover) e-con 8 point unit (circuit board) 32 point unit with terminal block e-con 584 e-con 8 point unit with terminal block Alphabetical Index Length Measuring/ Counter Static Electricity Elimination Equipment Reduced-wiring Fieldbus System Position Detection Switch Flow Sensor Pressure Control Series PCW Pressure Sensor The PC wiring system simplifies wiring between a PLC and all types of connected equipment. PC Wiring System Branch unit 585 Standardized pin layout Once 32 point terminal block unit or branch unit is replaced, no further wiring/design is necessary. Company A’s PLC I/O card Connector pin assignment (pin layout) Company B’s PLC I/O card Connector pin assignment (pin layout) Change of - 2F 2E 2D 2C 2B 2A 29 28 27 26 25 24 23 22 21 20 PLC manufacturers 11 13 15 17 19 1B 1D 1F + - 21 23 25 27 29 2B 2D 2F + - 1F 1E 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 (Company A to Company B) 10 12 14 16 18 1A 1C 1E + - 20 22 24 26 28 2A 2C 2E + - + + + + - General purpose terminal block unit Terminal block layout General purpose terminal block unit Terminal block layout + + + + - - 2F 2E 2D 2C 2B 2A 29 28 27 26 25 24 23 22 21 20 Terminal block layout 11 13 15 17 19 1B 1D 1F + - 21 23 25 27 29 2B 2D 2F + - 1F 1E 1D 1C 1B 1A 19 18 17 16 15 14 13 12 11 10 requires alteration. 10 12 14 16 18 1A 1C 1E + - 20 22 24 26 28 2A 2C 2E + - Poor performance in maintenance. Wiring must be redesigned again. PC wiring 32 point terminal block unit Terminal block layout Input device (sensor)/ output device (solenoid valve, etc.) to be connected. 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - PC Wiring system brings common layout. Adoption of e-con type eliminates the need for special tools and wire stripping. [Promoted or evaluated by] Mitsubishi Electric Corporation, OMRON Corporation, Fuji Electric Co., Ltd., Keyence Corporation, SUNX, Anywire Corporation, NKE, Kuroda Precision Industries Ltd., 3M, AMP, SMC Common unit can be used. Reduced spare parts enabling easier stock control. Input q Insert the electric cables into the cover. w Press with pliers. Input/output s. able r4c o f s d econ 10 s Output Elimination of branch unit The function of a branch unit is built-in a 16 point unit, allowing reduction of the number of units. Series PCW e-con specification Conventional Series PCW PLC input/output PLC input/output Branch unit Branch 16 point unit 16 point unit Reverse connection detection function Visual indication of incorrect wiring of power supply terminal block and power supply status is provided. 16 point unit 16 point unit Each unit available with cover compatible with DIN rail mounting or as circuit board. 2-color LED indication (Green): Normal (Red): Reverse connection (Off): Unconnected 586 Power supply terminal block With cover (DIN rail mount compatible) Circuit board type P. 589 PCW-EC (e-con Type) P. 590 Circuit board type With cover (DIN rail mount) P. 591 Circuit board type Circuit board type With cover (DIN rail mount) With cover (DIN rail mount) 16 point I/O unit 8 point I/O unit Unit with e-con combines branch unit with 16 point unit. 16 point unit with e-con allows common models used for both I/O units. 8 point unit with e-con allows common models used for both I/O units. Can use two 8 point I/O units in a cascade connection. PC Wiring System /Series P. 594 PCW P. 599 Branch unit: PLC direct connected type Branch unit 8 point branch unit Directly mounted on PLC I/O card. Connected to PLC I/O card via connection cable. Separates two of 8 point I/O transmissions once those are separated from two of 16 point I/O by the branch unit. P. 596 P. 598 32 point I/O unit 32 point output reduced common unit 16 point output reduced common unit Wired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks. Wired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks. Products with cross-over common wires are available. Wires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block. Products with cross-over common wires are available. Length Measuring/ Counter P. 600 16 point I/O unit 8 point I/O unit Wires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block. DIN rail mount type and box mount types are available. Wires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block. DIN rail mount type and box mount types are available. 587 Alphabetical Index P. 597 Static Electricity Elimination Equipment Reduced-wiring Fieldbus System P. 595 Position Detection Switch Flow Sensor P. 593 Pressure Control 16 point branch I/O unit Pressure Sensor PC Wiring /Series PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage Rated current 24 VDC Power supply line 2A Communication line 0.3 A Insulation resistance 5 MΩ or more at 100 VDC Withstand voltage 500 VAC Impact resistance 500 m/s2 Screw tightening torque (Phillips head Terminal block screwdriver/flat head screwdriver) specifications Wire stripping length (recommended) Connecting wire size Input/output connector CS0, CS1 0.4 to 0.6 Nm/0.4 to 0.7 Nm 7 mm AWG26 to 14 (0.13 to 2.5 mm2) Conforms to MIL-C-83503 CN0 to CNF e-con –25 to 75°C Ambient temperature e-con connector No need for special tools and wire stripping. Weight Model PCW-EC16ZBM00 PCW-EC16XBR00 PCW-EC16YBR00 PCW-EC16ZBM01 PCW-EC16XBR01 PCW-EC16YBR01 PCW-EC16Z00 PCW-EC16Z01 PCW-EC08Z00 PCW-EC08Z01 Weight (g) 47 87 38 78 31 58 q Insert the electric cables into the cover. Option (e-con Connector) Model 1 pc. w Press with pliers. 10 seconds for 4 cables. 588 10 pcs./pack AWG No. Cross section of Finished O.D. conductor ZS-28-C ZS-28-C-P 2 ZS-28-C-1 ZS-28-C-1P AWG26 to 24 0.14 to 0.2 mm ZS-28-C-2 ZS-28-C-2P Cover color ø0.8 to ø1.0 Red ø1.0 to ø1.2 Yellow ø1.2 to ø1.6 Orange Note) Applicability varies dependant on conductive construction, conductive material, and/or insulating material even resulting in inapplicable. Consult with SMC and manufacturer of connecting equipment. Series PCW-EC 16 Point Input/Output Branch Unit Dimensions CS1 - 2 3 4 5 6 7 8 9 A B C D E F 1 DC24V MADE IN JAPAN + *S2 S1 2 3 4 4 4 (28.5) 3 Flow Sensor 130 + - YMX-F4 1 2 3 4 5 6 7 8 9 A B C D E DC24V MADE IN JAPAN 2 3 4 + *S2 S1 (48.5) (50) 5.1 10.5 133 4.5 10.5 F 1 Position Detection Switch CS1 0 4.1 CSO IN 16.7 With cover (DIN rail mount compatible) 45 28.3 5 Reduced-wiring Fieldbus System 5 Models Input Output PCW-EC16XBR00 PCW-EC16YBR00 PCW-EC16XBR01 PCW-EC16YBR01 PCW-EC16ZBM00 PCW-EC16ZBM01 Note Circuit board type With cover (DIN rail mount compatible) Circuit board type With cover (DIN rail mount compatible) Length Measuring/ Counter ∗ Refer to pages 3 to 4 in CAT.02-20 about the circuit diagram. Alphabetical Index With cover (DIN rail mount compatible) Pressure Control 1 42 YMX-F4 0 4 + CSO IN Pressure Sensor 4-ø3.2 circuit board mounting hole Static Electricity Elimination Equipment Circuit board type 4 Circuit board type 589 Series PCW-EC 16 Point Input/Output Unit Models Circuit board type PCW-EC16Z00 PCW-EC16Z01 Circuit board type With cover (DIN rail mount compatible) ∗ Refer to page 5 in CAT.02-20 for the circuit diagram. Dimensions 4-ø3.2 circuit board mounting hole Circuit board type + PCW-EC16Z00 3 4 5 6 7 8 9 A B C D E F 1 2 3 4 + *S2 S1 4 4 2 42 - YMX-F4 1 4 DC24V MADE IN JAPAN 0 4 (28.5) 130 With cover (DIN rail mount compatible) + PCW-EC16Z01 45 28.3 16.7 With cover (DIN rail mount compatible) DC24V MADE IN JAPAN 1 2 3 4 5 6 7 8 9 A B C D E F 1 2 3 4 133 5.1 10.5 4.5 10.5 + *S2 S1 4.1 - YMX-F4 0 5 590 5 (48.5) (50) 3 Series PCW-EC 8 Point Input/Output Unit Models PCW-EC08Z00 PCW-EC08Z01 Circuit board type Pressure Sensor Circuit board type With cover (DIN rail mount compatible) ∗ Refer to page 6 in CAT.02-20 for the circuit diagram. Dimensions 4 + DC24V MADE IN JAPAN 0 1 2 3 4 5 YMX-F4 7 1 6 2 3 4 - 42 CS1 + *S2 S1 4 4 CS0 Pressure Control 4-ø3.2 circuit board mounting hole Circuit board type 4 (28.5) 3 80 Flow Sensor With cover (DIN rail mount compatible) 1 2 3 4 5 6 YMX-F4 7 1 2 3 4 83 + *S2 S1 5.1 10.5 (48.5) (50) 4.5 10.5 0 Reduced-wiring Fieldbus System CS1 Position Detection Switch 16.7 + CS0 DC24V MADE IN JAPAN 4.1 45 28.3 With cover (DIN rail mount compatible) Length Measuring/ Counter Static Electricity Elimination Equipment 5 Alphabetical Index 5 591 PC Wiring System Series PCW Common Specifications Rated voltage Rated current 24 VDC Power supply line 2A Communication line 0.3 A Insulation resistance 5 MΩ or more at 100 VDC 0.5 kV Impact resistance 500 m/s2 Terminal block Withstand voltage Power terminal (Phillips screw driver/Flat head screw driver) I/O terminal (Phillips screw driver/ Flat head screw driver) Wire stripping Power terminal length (recommended) I/O terminal Screw tightening torque Connecting wire size 0.4 to 0.6 Nm/0.4 to 0.7 Nm 0.5 to 0.6 Nm/0.5 to 0.7 Nm 7 mm AWG26 to 14 (0.13 to 2.5 mm2) AWG26 to 12 (0.13 to 4 mm2) Power terminal I/O terminal Cable Specifications PVC sheath Power lines Brown AWG20 (20, 40 cores) Blue Flat cable AWG28 With power lines Model Flat cable PCW9930661H PCW9903491H 20 cores 40 cores 20 cores Length 100 m roll AWG20 (21 wires/0.18 mm) 10.3 mm 12.0 mm 8.7 mm Note) The flat ribbon cable without power lines are not available from SMC. If required, please source locally from your preferred supplier. 592 34 cores 40 cores AWG28 (7 wires/0.127 mm) Power lines Sheath O.D. Without power lines 11.8 mm 13.0 mm Series PCW Branch Unit: PLC Direct Connected Type Specifications Weight 25 g Ambient temperature PLC –25 to 55°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Dimensions Pressure Sensor PLC connection Pressure Control Can be directly mounted on PLC. Models Input PCW-993104 PCW-993106 Note 1) Output PCW-993105 PCW-993107 Note 2) Circuit diagram Page 9 in CAT.E02-20 Page 10 in CAT.E02-20 Two pieces are required for 64 points of input/output. Note 1) Combine one piece each of PCW-993106 and PCW-993108 (the PLC connection side connectors are reversed). Note 2) Combine one piece each of PCW-993107 and PCW-993109 (the PLC connection side connectors are reversed). Caution Alphabetical Index Length Measuring/ Counter When removing a cable with connector, a PCW-04T puller is required. Reduced-wiring Fieldbus System 23.1 27.4 Static Electricity Elimination Equipment (5.2) 16.5 Position Detection Switch 70.1 Flow Sensor 18.2 593 Series PCW Branch Unit: DIN Rail Mount Type Specifications PLC connection Weight 80 g Ambient temperature PLC –25 to 80°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Connected to PLC via connection cable. Dimensions 10.5 10.5 45 28.3 16.7 103 4.1 RSOUT 5.1 49 50.5 4.5 (3.6) 5 ∗ Refer to page 50 in CAT.E02-20 for the junction cable part number. 5 Models Input Output Circuit diagram PCW-993023A PCW-993015A PCW-993045A PCW-993139A PCW-993033A PCW-993017A PCW-993047A PCW-993140A Page 13 in CAT.E02-20 Two pieces are required for 64 points of input/output. 594 Page 14 in CAT.E02-20 Page 19 in CAT.E02-20 Page 23 in CAT.E02-20 Series PCW 32 Point Input/Output Unit Specifications Weight 210 g Ambient temperature PLC –25 to 55°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Pressure Sensor PLC connection Pressure Control Connected to PLC via connection cable. Dimensions 178 10.5 CH IN OUT CH 5.1 (3.7) 0 1 2 - 3 + 4 - 5 + 6 - 7 + 8 - 9 + A - B + C - D + E - F + 53.5 55 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F - + - + - + - + - + - + - + - + - 5 5 Models Input Output Circuit diagram PCW-990344A PCW-993157A PCW-993161A PCW-990345A PCW-993158A PCW-993162A Page 25 in CAT.E02-20 Page 26 in CAT.E02-20 Static Electricity Elimination Equipment Page 35 in CAT.E02-20 Length Measuring/ Counter Two pieces are required for 64 points of input/output. Alphabetical Index ∗ Refer to page 50 in CAT.E02-20 for the junction cable part number. Position Detection Switch 4.5 + Flow Sensor 4.1 1 16.7 R S -AX/ 140- A 0 45 28.3 (3.6) Reduced-wiring Fieldbus System 10.5 595 Series PCW 32 Point Output Reduced Common Unit Specifications PLC connection Weight 130 g Ambient temperature PLC –25 to 55°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Connected to PLC via connection cable. Dimensions 10.5 10.5 103 OUT RS- 16.7 OD/040LP 4.1 45 28.3 (3.6) CH 1 CH 5.1 (3.7) 113 + ∗ Refer to page 50 in CAT.E02-20 for the junction cable part number. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4.5 - 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Models Output PCW-993193 PCW-993194 PCW-993225 Circuit diagram Page 37 in CAT.E02-20 Page 37 in CAT.E02-20 Page 39 in CAT.E02-20 Two pieces are required for 64 points of input/output. 596 53.5 55 Series PCW 16 Point Input/Output Unit Weight 125 g Ambient temperature –25 to 80°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. 103 10.5 16.7 10.5 5.1 Flow Sensor 4.1 45 28.3 IN OUT 53.5 55 4.5 Position Detection Switch (3.7) 5 5 Reduced-wiring Fieldbus System Terminal Block: Box Mount Type Specifications Models PCW-993055A Circuit diagram Output PCW-993056A Page 42 in CAT.E02-20 Weight Input 480 g Ambient temperature –25 to 80°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Dimensions 55 2 x ø5 machined for bar ring Mounting hole 10 10 6 1.2 55 65 67.4 (3.7) 59 5 4 x M3 x 0.5 55 CH IN OUT 33.5 (3) 139 8 40 10 55 6 x ø4 55 Alphabetical Index 41.2 2 x ø8 25 (2) 25 158 16 14 16 14 16 14 16 Static Electricity Elimination Equipment Dimensions Length Measuring/ Counter PCW-993051A Circuit diagram Output PCW-993052A Page 41 in CAT.E02-20 Input Pressure Control Specifications Models Pressure Sensor Terminal Block: DIN Rail Mount Type 597 Series PCW 16 Point Output Reduced Common Unit Specifications Model PCW-993195 Output Weight ∗ Refer to page 43 in CAT.E02-20 about the circuit diagram. 80 g Ambient temperature Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Dimensions 69 (3.6) 10.5 4.1 45 28.3 16.7 10.5 5.1 (3.7) 79 + 0 1 8 2 9 3 A 4 B 5 C 6 D 7 E F 4.5 - 598 –25 to 80°C 53.5 55 Series PCW 8 Point Branch Unit PCW-2K0072501 PCW-2K0072502 Output 80 g Weight Ambient temperature ∗ Refer to page 44 in CAT.E02-20 about the circuit diagram. –25 to 80°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Pressure Control Input Dimensions 10.5 103 Power supply terminal block 16.7 Input/Output connector 4.1 45 28.3 CNO Flow Sensor 10.5 CN2 5.1 49 50.5 Static Electricity Elimination Equipment Reduced-wiring Fieldbus System 4.5 Position Detection Switch 113 Length Measuring/ Counter (3.6) Alphabetical Index CN1 Input/Output connector Pressure Sensor Specifications Models 599 Series PCW 8 Point Input/Output Unit: HI/LO Setting Type Terminal Block: DIN Rail Mount Type Specifications Models Input Output PCW-993210 PCW-993211 HI PCW-993212 LO PCW-993213 HI LO Weight Circuit diagram Page 46 in CAT.E02-20 105 g Ambient temperature –25 to 80°C Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Circuit diagram Page 47 in CAT.E02-20 Dimensions 10.5 16.7 103 45 28.3 10.5 4.1 RS- (3.7) 113 53.5 55 4.5 5.1 Terminal Block: Box Mount Type Specifications Models Input PCW-993214 PCW-993215 HI PCW-993216 LO PCW-993217 HI LO Output Circuit diagram Page 48 in CAT.E02-20 Circuit diagram Page 49 in CAT.E02-20 Weight 365 g Ambient temperature Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 7 in CAT.E02-20. Dimensions 70 67.4 2 x ø5 118 (2) HI/LO setting This type is unnecessary to set jumpers (short-circuit sockets) with fixed higher/lower (HI/LO) orders of input/output units LO type: address assignment is fixed from “LO” 0 to 7. HI type: address assignment is fixed from “HI” 8 to F. 600 –25 to 80°C 41.2 (2) Series PCW PC Wiring System Connector Cable Pressure Sensor For Connection of PLC Input/Output Card to PCW Unit • PLC input/output card to PCW branch unit • PLC input/output card to PCW 32 point unit Pressure Control 005 Lead wire length Specifications 02 05 Specifications Standard specifications For connection of PCW unit compatible with KEYENCE CORP. PLC I/O card (KZ-C32X, KZ-C32T) Position Detection Switch Symbol Flow Sensor Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Dimensions PCW unit connection side MIL-C-83503 40 pin connector PCW unit connection side FCN manufactured by FUJITSU LIMITED 40 pin connector MIL-C-83503 40 pin connector Without power lines With power lines PLC connection side MIL-C-83503 34 pin connector PLC connection side PCW unit connection side MIL-C-83503 34 pin connector PLC connection side MIL-C-83503 34 pin connector PCW unit connection side MIL-C-83503 34 pin connector Length Measuring/ Counter FCN manufactured by FUJITSU LIMITED 40 pin connector Series PCW-05 Without power lines With power lines PLC connection side Alphabetical Index Series PCW-02 Reduced-wiring Fieldbus System Power supply line Symbol Power supply line Yes Nil No N Symbol Lead wire length 0.5 m 005 1m 010 1.5 m 015 2m 020 3m 030 5m 050 Static Electricity Elimination Equipment PCW 02 601 Series PCW PC Wiring System Connector Cable Branch Unit: Connection of PLC Direct Connecting Type to PCW Unit • Branch unit: Connection of PLC direct connecting type to PCW 16 point unit • Branch unit: Connection of PLC direct connecting type to PCW 8 point unit 005 PCW 04 Branch Unit: Connection of PLC Direct Connecting Type to Manifold Solenoid Valves • Branch unit: Connection of PLC direct connecting type to manifold solenoid valves 005 PCW 04 V Lead wire length Lead wire length Symbol Lead wire length 0.5 m 005 1m 010 1.5 m 015 2m 020 3m 030 5m 050 Symbol Lead wire length 0.5 m 005 1m 010 1.5 m 015 2m 020 3m 030 5m 050 Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Power supply lines Power supply lines Symbol Nil N Power supply lines Yes No Symbol Power supply lines Applicable manifold solenoid valve kit V N Yes No G kit J kit Refer to “Best Pneumatics No. 1” for details regarding applicable manifold solenoid valves. Dimensions Dimensions With power lines Branch unit: PLC direct connecting type connection side With power lines PCW unit connection side JM1S manufactured by IDEC Corporation 20 pin connector MIL-C-83503 20 pin connector Branch unit: PLC direct connecting type connection side JM1S manufactured by IDEC Corporation 20 pin connector Without power lines Branch unit: PLC direct connecting type connection side JM1S manufactured by IDEC Corporation 20 pin connector 602 Manifold solenoid valve connection side (G kit) MIL-C-83503 20 pin connector Without power lines PCW unit connection side MIL-C-83503 20 pin connector Branch unit: PLC direct connecting type connection side JM1S manufactured by IDEC Corporation 20 pin connector Manifold solenoid valve connection side (J kit) MIL-C-83503 20 pin connector Series PCW PC Wiring System 005 PCW 01 V Lead wire length Lead wire length Symbol 005 010 015 020 030 050 Pressure Control 005 PCW 01 • Connection of PCW branch unit to manifold solenoid valves • Connection of PCW 8 point unit to manifold solenoid valves Lead wire length 0.5 m 1m 1.5 m 2m 3m 5m Symbol Lead wire length 005 010 015 020 030 050 0.5 m 1m 1.5 m 2m 3m 5m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above. Power supply lines Power supply lines Symbol Power supply lines Yes Nil No N Symbol Power supply lines V N Yes No Applicable manifold solenoid valve kit G kit J kit Flow Sensor • Connection of PCW branch unit to PCW 16 point unit • Connection of PCW branch unit to PCW 8 point unit • Connection of PCW 8 point unit to PCW 8 point unit Connection of PCW Unit to Manifold Solenoid Valves Position Detection Switch Connection of PCW Unit to PCW Unit Pressure Sensor Connector Cable With power lines With power lines PCW unit connection side MIL-C-83503 20 pin connector MIL-C-83503 20 pin connector PCW unit connection side MIL-C-83503 20 pin connector MIL-C-83503 20 pin connector MIL-C-83503 20 pin connector Without power lines Without power lines PCW unit connection side Manifold solenoid valve connection side (G kit) PCW unit connection side MIL-C-83503 20 pin connector PCW unit connection side MIL-C-83503 20 pin connector Manifold solenoid valve connection side (J kit) MIL-C-83503 20 pin connector Alphabetical Index PCW unit connection side Static Electricity Elimination Equipment Dimensions Length Measuring/ Counter Dimensions Reduced-wiring Fieldbus System Refer to “Best Pneumatics No. 1” for details regarding applicable manifold solenoid valves. 603 Series PCW PC Wiring System Precautions 1 Be sure to read before handling. Refer to back page 1 for Safety Instructions. Operation Warning 1. This product is intended for use in general FA equipment. Avoid using this product in machinery or equipment which directly affects human lives or where malfunction or failure can cause extended damage. 2. Do not disassemble this product for repair or rebuilding. Mounting, Adjustment & Wiring Caution 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (500 m/s2 or more) during handling. The PC wiring system unit can be damaged and connected equipment may malfunction. 2. Be careful of incorrect wiring. Incorrect wiring may result in damage to connected equipment. The power supply will be short circuited if inputs and outputs are connected incorrectly for the 8 point/16 point input/output units following a branch unit. 3. Do not wire with power lines or high voltage lines. To prevent the intrusion of noise and surge from power and high voltage lines into signal lines, perform wiring for the PC wiring system separately (separate conduits) from power lines and high voltage lines. 4. Confirm proper insulation of wiring. Faulty insulation (crossed wiring, insulation defects between terminals, etc.) may result in damage to connected equipment, due to the application of excessive voltage or current flowing to the equipment. 5. Tighten screws with the proper tightening torque. If tightened beyond the tightening torque range, the terminal block and screws may be damaged. 6. Avoid subjecting cables to repeated bending or pulling forces. Wiring installations which result in repeated bending stress and pulling force on cables can cause broken wires. 7. Note that the disposition of I/O addresses differs for each PLC manufacturer. General purpose label sets (applicable to all manufacturers) are included, which can be cut as needed and inserted into the terminal label holders. 8. Operate within the rated current. The maximum current capacity for the power supply line on circuit boards of all units is 2.0 A. If the current passing through units such as the branch unit and input/output unit exceeds 2.0 A, connect the power supply line to the same power supply terminal and do not allow current to pass through the circuit board. Design & Selection Caution 1. Confirm the specifications. Use properly after confirming the specifications. Operation outside the range of specifications (voltage, ambient temperature, impact, etc.) can cause damage, malfunction or fire. 2. Ensure sufficient clearance for maintenance activities. When designing an application, be sure to allow sufficient clearance for maintenance and inspections. Operating Environment Caution 1. Absolutely do not use in an atmosphere with explosive gas. The PC wiring system is not an explosion-proof construction. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an environment with temperature cycles. Temperature cycles other than found with normal temperature changes may adversely affect the PC wiring system unit. 3. Do not use in an area where surges are generated. If there are devices or equipment that generate large surges (magnetic lifter, high-frequency induction furnace, motor, etc.) near the connected equipment or PC wiring system unit, the connected equipment may deteriorate or be damaged. Consider appropriate measures for any source of power surges and take care with crossed lines. 4. Keep wire scraps and other extraneous material from getting inside this product. This can cause fire, failure or malfunction, etc. Keep wire scraps and other extraneous material from getting inside this product. 5. Use with consideration for an operating environment with a protective structure. Avoid using the PC wiring system unit where water or oil is splashed. Maintenance & Inspection Caution 1. To prevent unintended malfunctioning, perform maintenance regularly. Unintended malfunctioning and misoperation may result in an inability to ensure safety. 2. Do not touch the terminals or internal boards when current is being suplied. Touching terminals or internal boards when current is being suplied may result in malfunctioning or damage with the PC wiring system unit or connected equipment, or electric shock. 604 Series PCW PC Wiring System Precautions 2 Be sure to read before handling. Refer to back page 1 for Safety Instructions. Pressure Sensor Design & Selection Warning 1. Only the output specification unit can be selected when combining each unit of Series PCW and Series PCW-EC. Pressure Control Please note: If an input specification unit is used, this may cause damage and/or possible burnout of any connected equipment. When used for PLC output card PLC output card Flow Sensor e-con type 16 point branch unit 16 point output unit Position Detection Switch PLC output card e-con type16 point unit Reduced-wiring Fieldbus System Output branch unit 16 point output unit When used for PLC input card Static Electricity Elimination Equipment PLC input card e-con type 16 point branch unit Length Measuring/ Counter 16 point input unit PLC input card e-con type16 point unit Alphabetical Index Input branch unit 16 point input unit 605
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement