VXD21/22/23 Series Direct Operated 2 Port Solenoid Valve

VXD21/22/23 Series Direct Operated 2 Port Solenoid Valve
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Air, Water, Oil
®
VX2
VXD
VXZ
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VCH첸
VDW
Solenoid valves for various fluids used in a wide variety of applications
VQ
LVM
VCA
Improved
corrosion
resistance
Special magnetic
material adopted
Enclosure:
IP65
Low-noise
construction
Special construction
enables to reduce the
metal noise. (DC spec.)
VCB
Reduced power
consumption
VCL
(DC spec.)
VCS
VXD21: 6 W
→ 4.5 W(VXD2140 to 2150) VCW
→ 5.5 W(VXD2130)
VXD22: 8 W→ 7 W
VXD23: 11.5 W
→ 10.5 W
Flame resistance
UL94V-0 conformed
Flame resistant mold coil material
mater
Improved
maintenance
performance
Maintenance is performed easily
due to the threaded assembly.
59
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
60
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Air, Water, Oil
VX2
VXD
Valve
Solenoid Coil
Coil: Class B, Class H
Rated Voltage
100 VAC, 200 VAC, 110 VAC,
220 VAC, 240 VAC, 230 VAC,
48 VAC, 24 VDC, 12 VDC
VXP
VXR
VXH
VXF
VXD227 20 VXD238 20 VXD239 20
Model
35 mmø
40 mmø
50 mmø
Port size
32A
40A
50A
(Flange)
VX3
Orifice dia.
Material
Seal
VXE
Orifice dia.
Note) Except VXD2130
Body
VXZ
VXD2130 VXD214 20 VXD215 20 VXD226 20
Model
10 mmø
15 mmø
20 mmø
25 mmø
1/4
3/8
Port size
3/4
3/8
1
(Thread)
1/2
1/2
Normally closed (N.C.)
Normally open (N.O.) Note)
Brass (C37)/CAC407,
Stainless steel
NBR, FKM, EPDM
VXA
VCH
VDW
Electrical Entry
VQ
• Grommet
• Conduit
• DIN terminal
• Conduit terminal
LVM
VCA
VCB
Contents
VCL
VCS
For Air ······································································································ P.64
VCW
For Water ································································································· P.66
For Oil ······································································································ P.68
Construction ····························································································· P.70
Dimensions ······························································································ P.72
Replacement Parts ·················································································· P.75
61
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-2-09-VXD.qxd
10.2.17 10:05 AM
Page 1
Series VXD21/22/23
Common Specifications
Standard Specifications
Pilot operated 2 port diaphragm type
Valve construction
8A to 25A: 5.0, 32A to 50A: 2.0
Withstand pressure (MPa)
Valve
specifications
Brass (C37), Stainless steel, CAC407
Body material
NBR, FKM, EPDM
Seal material
Dusttight, Low jetproof (equivalent to IP65) Note 1)
Enclosure
Location without corrosive or explosive gases
Environment
AC (Class B coil, Built-in full-wave rectifier type)
Rated voltage
100 VAC, 200 VAC, 110 VAC, 220 VAC, 230 VAC,
240 VAC, 48 VAC
AC (Class B coil/H coil) Note 2)
24 VDC, 12 VDC
DC (Class B coil only)
Coil
specifications
±10% of rated voltage
Allowable voltage fluctuation
Allowable
leakage
voltage
AC (Class B coil, Built-in full-wave rectifier type)
10% or less of rated voltage
AC (Class B coil/H coil) Note 2)
20% or less of rated voltage
DC (Class B coil only)
2% or less of rated voltage
Class B, Class H
Coil insulation type
Note 1) Electrical entry: Grommet with surge voltage suppressor (GS) has a rating of IP40.
Note 2) For the AC (Class B coil) of the VXD2130, built-in full-wave rectifier type is only applicable.
Be sure to read “Specific Product Precautions.”
Solenoid Coil Specifications
Normally Open (N.O.)
DC Specification
Normally Closed (N.C.)
DC Specification
Power consumption (W) Temperature rise (°C) Note)
Model
Power consumption (W) Temperature rise (°C) Note)
Model
VXD2130
5.5
50
VXD2142/2152
4.5
45
VXD2140/2150
4.5
45
VXD2262/2272
7
45
VXD2260/2270
7
45
VXD2382/2392
10.5
60
VXD2380/2390
10.5
60
Note) The values at ambient temperature of 20°C and when the rated voltage is applied.
Note) The values at ambient temperature of 20°C and when the rated voltage is applied.
AC Specification (Class B coil, Built-in full-wave rectifier type)
Apparent power (VA)∗ Temperature rise (°C) Note)
Model
AC Specification (Class B coil, Built-in full-wave rectifier type)
Apparent power (VA)∗ Temperature rise (°C) Note)
Model
VXD21
7
55
VXD21
7
55
VXD22
9.5
60
VXD22
9.5
60
65
VXD23
VXD23
12
12
65
∗ There is no difference in apparent power due to the inrush, energization, or
frequency of the power, since the AC (Class B coil, Built-in full-wave rectifier type)
uses a rectifying circuit.
Note) The values at ambient temperature of 20°C and when the rated voltage is applied.
∗ There is no difference in apparent power due to the inrush, energization, or
frequency of the power, since the AC (Class B coil, Built-in full-wave rectifier type)
uses a rectifying circuit.
Note) The values at ambient temperature of 20°C and when the rated voltage is applied.
AC Specification
AC Specification
Model
VXD21
VXD22
VXD23
Apparent power (VA)
Frequency (Hz)
Inrush
Energized
Temperature
rise (°C) Note)
50
19
10
50
60
16
8
45
50
43
20
65
60
35
17
60
50
62
32
65
60
52
27
60
Note) The values at ambient temperature of 20°C and when the rated voltage is applied.
Model
VXD21
VXD22
VXD23
Apparent power (VA)
Frequency (Hz)
Inrush
Energized
Temperature
rise (°C) Note)
50
22
11
55
60
18
8
50
50
46
20
65
60
38
18
60
50
64
32
65
60
54
27
60
Note) The values at ambient temperature of 20°C and when the rated voltage is applied.
62
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Applicable Fluid Check List
Pilot Operated 2 Port Solenoid Valve Series VXD21/22/23
Refer to pages 64, 66, and 68 for specifications and models.
All Options (8A to 25A)
3
140
VXD2 2 5 2
6
1
R1
Option
symbol
Fluid and application
Seal
material
Nil
Air
NBR
G
Nil
Water
G
E
P
A
H
D
N
Heated water
Oil
VX2
Option symbol
Note 2)
L
High corrosive spec., Oil-free
Copper-free, Fluorine-free Note 4)
Other combinations
NBR
EPDM
Push rod (N.O. only)
material Note 5)
Brass (C37)/–
FKM
Brass (C37)/Cu
Stainless steel/Ag
Brass (C37)/Cu
Stainless steel/Ag
PPS
Stainless steel/Ag
Brass (C37)/Cu
Stainless steel/Ag
FKM
EPDM
EPDM
Coil insulation
type Note 3)
B
Stainless steel/–
Brass (C37)/Cu
Note 1)
J
P
B
Body/Shading
coil material Note 6)
Note
VXD
Select the built-in full-wave
rectifier type for the AC spec.
B
VXE
H
VXP
B
VXR
H
VXH
Stainless steel/Ag
B
Stainless steel/Ag
B
Stainless steel/Ag
H
Brass (C37)/Cu
B
VXF
VX3
Note 1) “L” option is for oil-free treatment.
Note 2) The dynamic viscosity of the fluid must not exceed 50 mm2/s.
The special construction of the armature adopted in the built-in full-wave rectifier type gives an improvement in OFF response by providing clearance on the absorbed surface when it is switched ON.
Select the DC spec. or AC spec. built-in full-wave rectifier type when the dynamic viscosity is higher than water or when the OFF response is prioritized.
Note 3) Coil insulation type Class H: AC spec. only
Note 4) The nuts (non-wetted parts) are nickel-plated on the Brass (C37) material.
Note 5) N.O. for VXD2130 is not available.
Note 6) There is no shading coil attached to the DC spec. or AC spec built-in full-wave rectifier type.
27
VXD2 3 8 02
9
Body/Shading
coil material Note 4)
Air
Nil
NBR
Nil
E
A
D
B
Oil
Note 2)
Other combination
VCB
Option symbol
Seal
material
Heated water
VDW
VCA
1
R1
Option
symbol
Note 1)
VCH
LVM
Refer to pages 64, 66, and 68 for specifications and models.
Fluid and application
Water
VXA
VQ
∗ Please contact SMC when fluids other than above are used.
All Options (32A to 50A)
VXZ
VCL
Coil insulation
type Note 3)
Note
CAC407/—
B
Select the built-in full-wave
rectifier type for the AC spec.
NBR
CAC407/Cu
B
EPDM
CAC407/Cu
FKM
EPDM
Push rod (N.O. only)
material
PPS
VCS
VCW
H
CAC407/Cu
B
CAC407/Cu
H
CAC407/Cu
B
Note 1) The highest operating temperature of 32A to 50A is 80°C.
Note 2) The dynamic viscosity of the fluid must not exceed 50 mm2/s.
The special construction of the armature adopted in the built-in full-wave rectifier type gives an improvement in OFF response by providing clearance on the absorbed surface when it is switched ON.
Select the DC spec. or AC spec built-in full-wave rectifier type when the dynamic viscosity is higher than water or when the OFF response is prioritized.
Note 3) Coil insulation type Class H: AC spec. only
Note 4) There is no shading coil attached to the DC spec. or AC spec built-in full-wave rectifier type.
∗ Please contact SMC when fluids other than above are used.
63
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXD21/22/23
When the fluid is air.
For Air
(Inert gas)
Model/Valve Specifications
Please select the built-in full wave rectifier type when the fluid is air.
• The special construction of the armature reduces abrasion, resulting in a longer service life.
• Reduced buzz noise
Best suited for medical equipment, low-noise environments,
etc.
Normally closed (N.C.)
Passage symbol
2
1
Port size
1/4 (8A)
Thread
(Nominal
size)
3/8 (10A)
1/2 (15A)
3/4 (20A)
Port size
Thread (Nominal size)
Flange
1 (25A)
32A
40A
50A
Min. operating
pressure differential
(MPa)Note 1)
Orifice dia.
(mmø)
Model
10
10
15
10
15
20
VXD2130-02
VXD2130-03
VXD2140-03
VXD2130-04
VXD2140-04
VXD2150-06
0.02
Orifice dia.
(mmø)
Model
Min. operating
pressure differential
(MPa) Note 1)
25
35
40
50
VXD2260-10
VXD2270-32
VXD2380-40
VXD2390-50
Max. operating pressure
differential (MPa)
DC
AC
0.9
0.7
1.0
0.9
1.0
0.7
1.0
1.0
Max. operating pressure
differential (MPa)
AC, DC
0.02
1.0
0.03
Flow characteristics
C
8.5
9.2
18.0
9.2
20.0
38.0
b
0.35
0.30
Cv
2.0
2.4
5.0
2.4
5.5
9.5
Flow characteristics
Effective area (mm2)
225
415
560
880
Max. system
pressure
(MPa)
Note 2)
Mass
(g)
420
1.5
670
500
670
1150
Note 2)
Max. system
pressure
(MPa)
Mass
(g)
1.5
1650
5400
6800
8400
Note 1) Be aware that even if the pressure difference is above the Min. operating pressure differential when the valve is closed, the pressure difference may fall below the
Min. operating pressure differential when the valve opens depending on the power of the supply source (pumps, compressors etc.,) or the type of pipe restrictors
used.
Note 2) Mass of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure.
Normally open (N.O.)
Passage symbol
2
1
Port size
Thread
(Nominal
size)
3/8 (10A)
1/2 (15A)
3/4 (20A)
Port size
Thread (Nominal size)
Flange
1 (25A)
32A
40A
50A
Min. operating
pressure differential
(MPa) Note 1)
Max. operating pressure
differential (MPa)
AC, DC
VXD2142-03
VXD2142-04
VXD2152-06
0.02
0.7
Orifice dia.
(mmø)
Model
Min. operating
pressure differential
(MPa)Note 1)
25
35
40
50
VXD2262-10
VXD2272-32
VXD2382-40
VXD2392-50
Orifice dia.
(mmø)
15
20
Model
Max. operating pressure
differential (MPa)
AC, DC
0.02
0.03
0.7
Flow characteristics
C
18.0
20.0
38.0
b
0.35
0.30
Cv
5.0
5.5
9.5
Flow characteristics
Effective area (mm2)
225
415
560
880
Max. system
pressure
(MPa)
1.5
Note 2)
Mass
(g)
690
1170
Note 2)
Max. system
pressure
(MPa)
Mass
(g)
1.5
1690
5400
6800
8400
Note 1) Be aware that even if the pressure difference is above the Min. operating pressure differential when the valve is closed, the pressure difference may fall below the
Min. operating pressure differential when the valve opens depending on the power of the supply source (pumps, compressors etc.,) or the type of pipe restrictors
used.
Note 2) Mass of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure.
Fluid and Ambient Temperature
Valve Leakage Rate
Internal Leakage
Power source
AC
DC
Fluid temperature (°C)
Solenoid valve option symbol
Nil, G
–10 Note) to 60
–10 to 60
Note) Dew point temperature: –10°C or less
Ambient
temperature
(°C)
–10 to 60
Seal material
NBR, FKM
Leakage rate (Air)
1/4 to 1
32A to 50A
2 cm3/min or less
10 cm3/min or less
External Leakage
Seal material
NBR, FKM
Leakage rate (Water)
1/4 to 1
32A to 50A
0.1 cm3/min or less
0.1 cm3/min or less
64
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Air
How to Order
VXD 21 3 0
VXD 21 3 0
DC
AC
Model
N.C. / Single unit
N.O. / Single unit
Refer to the table (2) shown below for availability.
Built-in full-wave
rectifier type
Port size
Thread type
Suffix
G - Grommet
GS- With grommet surge
6
7
8
J
C- Conduit
D - DIN termnal
DS - DIN terminal with surge
surge voltage suppressor
and light
TZ - With conduit termi-
voltage suppressor and
light
DO - For DIN terminal (without connector,
gasket is included.)
∗ DIN type is available with class B only.
nal, surge voltage
suppressor and light
∗ Refer to the table (3) for the available combinations between each electrical option (S, L, Z)
and rated voltage.
∗ Option “S”, “Z” are not available as surge voltage suppressor is integrated into the AC/Class
B coil, as a standard.
Solenoid valve (Port size)
VXD21
Thread
Port no.
(Port size)
VXD22
Orifice symbol (Diameter)
VXD23
VXH
DL - DIN terminal with light
DZ - DIN terminal with surge
Refer to page 75 for ordering coil only.
Model
Connector
voltage suppressor
TL - With conduit terminal
∗ Refer to the table (3) shown below for availability.
Normally closed (N.C.)
3
4
5
6
Material
7
8
9
Body
(10 mmø) (15 mmø) (20 mmø) (25 mmø) (35 mmø) (40 mmø) (50 mmø)
Seal
Brass (C37),
Stainless
steel
VXD22
Orifice symbol (Diameter)
VXD23
4
5
G
7
8
9
NBR
Body
40 (40A)
50 (50A)
VCS
VCW
NBR
CAC407
Table (3) Rated Voltage – Electrical Option
Coil
Body/
Shading coil material insulation
type
Brass (C37)/Cu Note)
Stainless steel/Ag
VCL
Seal
Brass (C37),
Stainless
steel
Table (2) Solenoid Valve Option
Nil
6
(15 mmø) (20 mmø) (25 mmø) (35 mmø) (40 mmø) (50 mmø)
10 (1)
32 (32A)
Seal
material
VDW
VCB
Material
03 (3/8)
04 (1/2)
06 (3/4)
Flange
Option
symbol
VCH
LVM
CAC407
Solenoid valve (Port size)
Port no.
(Port size)
VXA
NBR
Normally open (N.O.)
Thread
VX3
VCA
40 (40A)
50 (50A)
Flange
VXD21
VXF
VQ
02 (1/4)
03 (3/8)
04 (1/2)
06 (3/4)
10 (1)
32 (32A)
Model
VXE
VXR
T - With conduit terminal
TS - With conduit terminal and
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
Table (1) Model/Orifice Diameter/Port Size
VXD
VXP
voltage suppressor
Rated voltage
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
VX2
VXZ
Electrical entry
Rc
NPTF
G
NPT
T
F
N
—
Oil-free spec.
1
2
3
4
5
∗ Bracket is not removable.
Solenoid valve option
Nil
None
With bracket
B
Refer to the table (1) shown below for availability.
∗ N.O. for VXD2130 is not
available.
Z
Bracket
Nil
Refer to the table (1) shown
below for availability.
Valve/Body configuration
Nil
5 G 1
1 G R1
Orifice diameter
Refer to the table (1) shown
below for availability.
0
2
02
02
B
Rated voltage
Note
—
AC/
DC
Note) CAC407 for 32A to 50A.
AC
DC
Class B
S
With surge
Voltage
Voltage voltage
symbol
suppressor
100 V
1
200 V
2
110 V
3
Note)
220 V
4
240 V
7
48 V
8
230 V
J
앬
24 V
5
앬
12 V
6
L
With
light
Class H
Z
S
With light and With surge
surge voltage
voltage
suppressor suppressor
L
Z
With
light
With light and
surge voltage
suppressor
Note)
앬
—
DC spec. is not available.
Note) Option “S”, “Z” are not available as surge voltage suppressor is integrated into the
AC/Class B coil, as a standard.
65
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-2-09-VXD.qxd
10.2.17 10:05 AM
Page 2
Series VXD21/22/23
For Water
Model/Valve Specifications
Normally closed (N.C.)
Passage symbol
2
1
Port size
Model
10
10
15
10
15
20
25
35
40
50
VXD2130-02
VXD2130-03
VXD2140-03
VXD2130-04
VXD2140-04
VXD2150-06
VXD2260-10
VXD2270-32
VXD2380-40
VXD2390-50
1/4 (8A)
Thread
(Nominal
size)
Flange
Min. operating
pressure differential
(MPa) Note 1)
Orifice dia.
(mmø)
3/8 (10A)
1/2 (15A)
3/4 (20A)
1 (25A)
32A
40A
50A
0.02
Max. operating pressure
differential (MPa)
DC
AC
0.7
0.5
1.0
0.7
1.0
0.5
1.0
1.0
0.03
Max. system
pressure
(MPa)
Cv converted
1.9
2.4
4.5
2.4
5.5
1.5
9.5
13
23
31
49
Flow characteristics
Av x 10-6m2
46
58
110
58
130
230
310
550
740
1200
Note 2)
Mass
(g)
420
670
500
670
1150
1650
5400
6800
8400
Note 1) Be aware that even if the pressure difference is above the Min. operating pressure differential when the valve is closed, the pressure difference may fall below the
Min. operating pressure differential when the valve opens depending on the power of the supply source (pumps, compressors etc.,) or the type of pipe restrictors
used.
Note 2) Mass of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure.
Normally open (N.O.)
Passage symbol
2
1
Port size
Thread
(Nominal
size)
Flange
Orifice dia.
(mmø)
3/8 (10A)
1/2 (15A)
3/4 (20A)
1 (25A)
32A
40A
50A
15
20
25
35
40
50
Model
VXD2142-03
VXD2142-04
VXD2152-06
VXD2262-10
VXD2272-32
VXD2382-40
VXD2392-50
Min. operating
pressure differential
(MPa) Note 1)
Max. operating pressure
differential (MPa)
AC, DC
0.02
0.7
0.03
Max. system
pressure
(MPa)
Cv converted
4.5
5.5
9.5
13
1.5
23
31
49
Flow characteristics
Av x 10-6m2
110
130
230
310
550
740
1200
Note 2)
Mass
(g)
690
1170
1690
5400
6800
8400
Note 1) Be aware that even if the pressure difference is above the Min. operating pressure differential when the valve is closed, the pressure difference may fall below the
Min. operating pressure differential when the valve opens depending on the power of the supply source (pumps, compressors etc.,) or the type of pipe restrictors
used.
Note 2) Mass of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure.
Fluid and Ambient Temperature
Valve Leakage Rate
Internal Leakage
Power source
AC
DC
Fluid temperature (°C)
Solenoid valve option symbol
Nil, G, L
E, P Note 1)
1 to 99
1 to 60
—
Note 1) 1 to 80°C for 32A to 50A.
Note 2) With no freezing
Ambient
temperature
(°C)
NBR, FKM, EPDM
–10 to 60
External Leakage
Seal material
Seal material
NBR, FKM, EPDM
Leakage rate (Water)
1/4 to 1
32A to 50A
0.2 cm3/min or less
1 cm3/min or less
Leakage rate (Water)
1/4 to 1
32A to 50A
0.1 cm3/min or less
0.1 cm3/min or less
66
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Water
How to Order
DC/AC (Except
VXD2130 AC/Class B)
AC/Class B coil (Built-in
full-wave rectifier type)
VXD 21 3 0
VXD 21 3 0
02
02
5 G 1
1 G R1
∗ For the AC (Class B coil) of the VXD2130, built-in
full-wave rectifier type is only applicable.
Model
Refer to the table (1) shown below for availability.
Thread type
∗ N.O. for VXD2130 is not available.
Nil
Solenoid valve option
Refer to the table (2) shown
below for availability.
Note) Class B oil-free AC coils are
applicable to the full-wave
rectifier type only. Select
the built-in full-wave rectifier
type.
Nil
Z
—
Oil-free spec.
G - Grommet
GS- With grommet surge
6
7
8
J
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
Refer to page 75 for ordering coil only.
D - DIN terminal
DS - DIN terminal with surge
surge voltage suppressor
VXH
voltage suppressor
TL - With conduit terminal
DL - DIN terminal with light
DZ - DIN terminal with surge
and light
TZ - With conduit
voltage suppressor
and light
DO - For DIN terminal (without
connector, gasket is included.)
∗ DIN type is available with class B only.
terminal, surge
voltage suppressor
and light
Solenoid valve (Port size)
Orifice symbol (Diameter)
VXD23
Connector
∗ Refer to the table (3) for the available combinations between each electrical option (S, L, Z)
and rated voltage.
∗ Option “S”, “Z” are not available as surge voltage suppressor is integrated into the AC/Class
B coil, as a standard.
Normally closed (N.C.)
Thread
3
4
5
6
Material
7
8
9
Body
(10 mmø) (15 mmø) (20 mmø) (25 mmø) (35 mmø) (40 mmø) (50 mmø)
Seal
Brass (C37),
Stainless
steel
NBR
FKM
EPDM
CAC407
40 (40A)
50 (50A)
Flange
Solenoid valve (Port size)
Thread
Port no.
(Port size)
VXD22
Orifice symbol (Diameter)
VXD23
4
5
6
7
8
9
L Note 1)
NBR
EPDM
FKM
VCH
VDW
Stainless steel/Ag
VCA
VCS
VCW
NBR
FKM
EPDM
Table (3) Rated Voltage – Electrical Option
Coil
Body/
Shading coil material insulation
type
Brass (C37)/Cu Note 2)
Stainless steel/Ag
Brass (C37)/Cu Note 2)
Stainless steel/Ag
LVM
CAC407
Table (2) Solenoid Valve Option
G
E
P
Seal
Brass (C37),
Stainless
steel
40 (40A)
50 (50A)
Flange
Nil
Body
(15 mmø) (20 mmø) (25 mmø) (35 mmø) (40 mmø) (50 mmø)
03 (3/8)
04 (1/2)
06 (3/4)
Seal
material
VXA
VCL
Material
10 (1)
32 (32A)
Option
symbol
VX3
VCB
Normally open (N.O.)
VXD21
VXF
VQ
02 (1/4)
03 (3/8)
04 (1/2)
06 (3/4)
10 (1)
32 (32A)
Model
VXE
VXR
Table (1) Model/Orifice diameter/Port Size
Port no.
(Port size)
VXD
VXP
T - With conduit terminal
TS - With conduit terminal and
Rated voltage
VXD22
C- Conduit
voltage suppressor
∗ Refer to the table (3) shown below for availability.
VXD21
VX2
VXZ
Electrical entry
Rc
NPTF
G
NPT
T
F
N
Suffix
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
Model
Built-in full-wave
rectifier type
Port size
N.C. / Single unit
N.O. / Single unit
1
2
3
4
5
∗ Bracket is not removable.
Refer to the table (1) shown
below for availability.
Valve/Body configuration
None
With bracket
B
Orifice diameter
Refer to the table (1) shown
below for availability.
0
2
Bracket
Nil
Rated voltage
Note
B
—
H
Heated water
(AC only)
B
High corrosive,
Oil-free
AC/
DC
AC
Note 1) Select nil because option "L" is the oil-free treatment.
Note 2) CAC407 for 32A to 50A.
DC
Class B
S
With surge
Voltage
Voltage voltage
symbol
suppressor
1
100V
2
200V
3
110V
4
220V
7
240V
8
48V
J
230V
5
24V
6
12V
L
With
light
Class H
Z
S
With light and With surge
surge voltage
voltage
suppressor suppressor
L
Z
With
light
With light and
surge voltage
suppressor
DC spec. is not available.
Note) Option “S”, “Z” are not available as surge voltage suppressor is integrated into the
AC/Class B coil, as a standard.
67
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXD21/22/23
When the fluid is oil.
The dynamic viscosity of the fluid must not exceed 50
mm2/s.
The special construction of the armature adopted in the
built-in full-wave rectifier type gives an improvement in OFF
response by providing clearance on the absorbed surface
when it is switched ON.
Select the DC spec. or AC spec. built-in full-wave rectifier
type when the dynamic viscosity is higher than water or
when the OFF response is prioritized.
For Oil
Model/Valve Specifications
Normally closed (N.C.)
Passage symbol
2
1
Port size
1/4 (8A)
Thread
(Nominal
size)
Flange
3/8 (10A)
1/2 (15A)
3/4 (20A)
1 (25A)
32A
40A
50A
Min. operating
pressure differential
(MPa) Note 1)
Orifice dia.
(mmø)
Model
10
10
15
10
15
20
25
35
40
50
VXD2130-02
VXD2130-03
VXD2140-03
VXD2130-04
VXD2140-04
VXD2150-06
VXD2260-10
VXD2270-32
VXD2380-40
VXD2390-50
0.02
Max. operating pressure
differential (MPa)
DC
AC
0.5
0.4
0.7
0.5
0.7
0.4
0.7
0.7
0.03
Max. system
pressure
(MPa)
Cv converted
1.9
2.4
4.5
2.4
5.5
1.5
9.5
13
23
31
49
Flow characteristics
Av x 10-6m2
46
58
110
58
130
230
310
550
740
1200
Note 2)
Mass
(g)
420
670
500
670
1150
1650
5400
6800
8400
Note 1) Be aware that even if the pressure difference is above the Min. operating pressure differential when the valve is closed, the pressure difference may fall below the
Min. operating pressure differential when the valve opens depending on the power of the supply source (pumps, compressors etc.,) or the type of pipe restrictors
used.
Note 2) Mass of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure.
Normally open (N.O.)
Passage symbol
2
1
Orifice dia.
(mmø)
Port size
Thread
(Nominal
size)
Flange
3/8 (10A)
1/2 (15A)
3/4 (20A)
1 (25A)
32A
40A
50A
15
20
25
35
40
50
Model
VXD2142-03
VXD2142-04
VXD2152-06
VXD2262-10
VXD2272-32
VXD2382-40
VXD2392-50
Min. operating
pressure differential
(MPa) Note 1)
Max. operating pressure
differential (MPa)
AC, DC
0.02
0.6
0.03
Max. system
pressure
(MPa)
Cv converted
4.5
5.5
9.5
13
1.5
23
31
49
Flow characteristics
Av x 10-6m2
110
130
230
310
550
740
1200
Note 2)
Mass
(g)
690
1170
1690
5400
6800
8400
Note 1) Be aware that even if the pressure difference is above the Min. operating pressure differential when the valve is closed, the pressure difference may fall below the
Min. operating pressure differential when the valve opens depending on the power of the supply source (pumps, compressors etc.,) or the type of pipe restrictors
used.
Note 2) Mass of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
• Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure.
Fluid and Ambient Temperature
Valve Leakage Rate
Internal Leakage
Power source
AC
DC
Fluid temperature (°C)
Solenoid valve option symbol
A, H
D, N
–5 to 60
–5 to 100
—
Note) Dynamic viscosity: 50
mm2/s
or less
Ambient
temperature
(°C)
Seal material
–10 to 60
External Leakage
FKM
Seal material
FKM
Leakage rate (Oil)
32A to 50A
1/4 to 1
0.2 cm3/min or less
1 cm3/min or less
Leakage rate (Oil)
32A to 50A
1/4 to 1
0.1 cm3/min or less
0.1 cm3/min or less
68
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Oil
How to Order
DC/AC (Except
VXD2130 AC/Class B)
AC/Class B coil (Built-in
full-wave rectifier type)
VXD 21 3 0
VXD 21 3 0
02
02
5 G 1
1 G R1
∗ For the AC (Class B coil) of the VXD2130, built-in
full-wave rectifier type is only applicable.
Model
Orifice diameter
Refer to the table (1) shown
below for availability.
Thread type
Nil
Solenoid valve option
Refer to the table (2) shown
below for availability.
Note) Class B oil-free AC coils are
applicable to the full-wave
rectifier type only. Select
the built-in full-wave rectifier
type.
Nil
Z
—
Oil-free spec.
G - Grommet
GS- With grommet surge
surge voltage suppressor
Thread
Port no.
(Port size)
VXD22
VXH
DL - DIN terminal with light
DZ - DIN terminal with surge
and light
TZ - With conduit
voltage suppressor
and light
DO - For DIN terminal (without connector,
gasket is included.)
∗ DIN type is available with class B only.
terminal, surge
voltage suppressor
and light
Orifice symbol (Diameter)
VXD23
Connector
voltage suppressor
TL - With conduit terminal
Solenoid valve (Port size)
VXD21
D - DIN terminal
DS - DIN terminal with surge
∗ Refer to the table (3) for the available combinations between each electrical option (S, L, Z)
and rated voltage.
∗ Option “S”, “Z” are not available as surge voltage suppressor is integrated into the AC/Class
B coil, as a standard.
Normally closed (N.C.)
3
4
5
6
Material
7
8
9
Body
(10 mmø) (15 mmø) (20 mmø) (25 mmø) (35 mmø) (40 mmø) (50 mmø)
Seal
Brass (C37),
Stainless
steel
VXD22
Orifice symbol (Diameter)
VXD23
4
5
6
7
8
9
Body
(15 mmø) (20 mmø) (25 mmø) (35 mmø) (40 mmø) (50 mmø)
10 (1)
32 (32A)
40 (40A)
50 (50A)
Seal
material
Body/
Shading coil material
FKM
Brass (C37)/Cu Note 2)
Stainless steel/Ag
Brass (C37)/Cu Note 2)
Stainless steel/Ag
VCL
Seal
Brass (C37),
Stainless
steel
VCS
VCW
FKM
CAC407
Table (2) Solenoid Valve Option
A
H
D
N
VDW
VCB
Material
03 (3/8)
04 (1/2)
06 (3/4)
Flange
Option
symbol
VCH
VCA
Solenoid valve (Port size)
Port no.
(Port size)
VXA
LVM
Normally open (N.O.)
Thread
VX3
FKM
CAC407
40 (40A)
50 (50A)
Flange
VXD21
VXF
VQ
02 (1/4)
03 (3/8)
04 (1/2)
06 (3/4)
10 (1)
32 (32A)
Model
VXE
VXR
∗ Refer to the table (3) shown below for availability.
Table (1) Model/Orifice diameter/Port Size
VXD
VXP
T - With conduit terminal
TS - With conduit terminal and
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
Refer to page 75 for ordering coil only.
C- Conduit
voltage suppressor
Rated voltage
6
7
8
J
VX2
VXZ
Electrical entry
Rc
NPTF
G
NPT
T
F
N
Suffix
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
Model
Built-in full-wave
rectifier type
Refer to the table (1) shown below for availability.
∗ N.O. for VXD2130 is not available.
1
2
3
4
5
∗ Bracket is not removable.
Port size
N.C. / Single unit
N.O. / Single unit
None
With bracket
B
Refer to the table (1) shown
below for availability.
Valve/Body configuration
0
2
Bracket
Nil
Table (3) Rated Voltage – Electrical Option
Rated voltage
Coil insulation type
B
AC/
DC
H
Note 1) The additives contained in oil are different depending on the manufacturer,
so the durability of the seal materials will vary. For details, please consult
with SMC.
Note 2) CAC407 for 32A to 50A.
AC
DC
Class B
S
With surge
Voltage
Voltage voltage
symbol
suppressor
1
100V
2
200V
3
110V
4
220V
7
240V
8
48V
J
230V
5
24V
6
12V
L
With
light
Class H
Z
S
With light and With surge
surge voltage
voltage
suppressor suppressor
L
Z
With
light
With light and
surge voltage
suppressor
DC spec. is not available.
Note) Option “S”, “Z” are not available as surge voltage suppressor is integrated into the
AC/Class B coil, as a standard.
69
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXD21/22/23
For Air, Water, Oil
Construction
Normally closed (N.C.)
Body material: Brass (C37) (32A or larger: CAC407), Stainless steel (32A or larger: not available)
VXD2130 (8A/10A)
!2
!1
!0
u
i
r
o
e
y
w IN
t
q
VXD2140, 2150, 2260
(10A to 25A)
A
e
r
o
A
B
P1
C
P2
OUT
P1
w
t
y
B
q
VXD2270, 2380, 2390 (32A to 50A)
!2
!1
!0
!2
!1
u
!0
i
P2
OUT
IN
C
w
u
r
e
i
o
A
C
y
B
t
q
Operation
<Valve opened> When the coil !0 is energized, the armature assembly i is
attracted into the core of the tube assembly u and the pilot valve A opens.
Then the pressure in the pressure action chamber B falls to open the main
valve C.
<Valve closed> When the coil !0 is not energized, the pilot valve A is closed
and the pressure in the pressure action chamber B rises and the main valve
C closes.
Component Parts
No.
1
Description
Body
Size
8A to 25A
Material
Standard
Option
Brass (C37)
Stainless steel
CAC407
32A to 50A
8A to 25A
Brass (C37)
Stainless steel
2
Bonnet
3
Nut
8A to 50A
Brass (C37)
4
O-ring
8A to 50A
NBR
FKM, EPDM
8A to 25A
Stainless steel, NBR
Stainless steel, FKM / Stainless steel, EPDM
32A to 50A
Stainless steel, Brass (C37), NBR
5
Diaphragm assembly
6
Valve spring
7
Tube assembly
CAC407
32A to 50A
8A to 25A
8
Armature assembly
8A to 50A
Stainless steel, FKM, EPDM
Stainless steel
8A to 50A
32A to 50A
Brass (C37), Ni plated
Stainless steel, Ag
Stainless steel, Cu
—
Stainless steel, PPS, FKM
Stainless steel, EPDM
Stainless steel, PPS, NBR
Stainless steel
9
Return spring
8A to 50A
10
Solenoid coil
8A to 50A
11
Name plate
8A to 50A
Aluminum
12
Clip
8A to 50A
SK
Class B molded
Class H molded
70
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Air, Water, Oil
Normally open (N.O.)
Body material: Brass (C37) (32A or larger: CAC407), Stainless steel (32A or larger: not available)
VXD2142, 2152, 2262
VXD2272, 2382, 2392 (32A to 50A)
(10A to 25A)
P1
w
t
y
B
q
!3
!4
!2
!0
u
r
e
!1
o
A
!3
!4
!2
i
!0
!1
u
e
r
o
A
i
VXD
w
VXZ
C
VXE
VXP
VXR
VXH
y
B
t
q
P2
OUT
IN
VX2
C
VXF
VX3
VXA
Operation
<Valve opened> When the coil !0 is energized, the opened pilot A closes,
the pressure in pressure action chamber B rises and the main valve C
closes.
<Valve closed> When the coil !0 is not energized, the closed pilot valve
A opens, the pressure in pressure action chamber B drops and the main
valve C opens.
VCH
VDW
VQ
Component Parts
No.
Description
Size
10A to 25A
Material
Standard
LVM
Option
Brass (C37)
Stainless steel
VCA
Stainless steel
VCB
Brass (C37)
Brass (C37), Ni plated
NBR
FKM, EPDM
VCL
10A to 25A
Stainless steel, NBR
Stainless steel, FKM / Stainless steel, EPDM
32A to 50A
Stainless steel, NBR
Stainless steel, FKM, EPDM
1
Body
2
Bonnet
3
Nut
10A to 25A
4
O-ring
10A to 50A
5
Diaphragm assembly
6
Valve spring
32A to 50A
10A to 25A
CAC407
Brass (C37)
32A to 50A
CAC407
10A to 25A
10A to 25A
7
Tube assembly
8
Armature assembly
10A to 50A
32A to 50A
VCS
Stainless steel
VCW
Stainless steel, Ag
Stainless steel, Cu
—
Stainless steel
9
Return spring
10A to 50A
10
Solenoid coil
10A to 50A
Class B molded
Class H molded
11
Push rod assembly
10A to 50A
NBR, PPS, Stainless steel
FKM, EPDM, Stainless steel
12
Name plate
10A to 50A
13
Clip
10A to 50A
SK
14
Cover
10A to 50A
Stainless steel
Stainless steel
Aluminum
71
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXD21/22/23
For Air, Water, Oil
Dimensions: Body Material: Brass (C37), Stainless Steel
Normally closed (N.C.): VXD2130
Grommet: G
Conduit: C
(67)
(52)
19.5
30
Approx. 280
G1/2
U
19.5
T
Width
across
flats 27
A
T
(5.5)
(1.6)
(7.5)
a
b
A
Width
across
flats 27
U
Approx. 300
30
IN
OUT
B
OUT
B
IN
Bracket
L
(28)
K
(50)
M
2xP
40
1 (IN), 2 (OUT) port
40
DIN terminal: D
L
2xP
1 (IN), 2 (OUT) port
M
K
(50)
Conduit terminal: T
U
V
(U)
19.5
(V)
34
19.5
T
A
25
Width
across
flats 27
31.5
(44)
Width
across
flats 27
T
A
32
30
G1/2
OUT
IN
M
Cable
ø6 to ø12
40
OUT
B
B
IN
G1/2
L
K
M
(50)
L
2xP
1 (IN), 2 (OUT) port
40
K
(50)
2xP
1 (IN), 2 (OUT) port
VXD2130-04-
Note) A thread is drilled on the bottom of the body
of the VXD2130 with port size 04 (1/2).
18
2 x M5 x 8 thread depth 8
(mm)
Model
N.C.
VXD2130
Port size
P
1/4, 3/8
1/2
A
80.5
86
B
11
14.5
K
20
24
L
30
26
M
22
28
Electrical entry
DIN terminal
Grommet
Conduit
T
U
T
U
T
U
V
Conduit terminal
T
U
V
62
64
19.5
19.5
54.5
56.5
40
40
54
56
58.5
58.5
46.5
46.5
54.5
56.5
92
92
61
61
(mm)
Model
N.C.
VXD2130
Port size
P
1/4, 3/8
1/2
Electrical entry (Built-in full-wave rectifier type)
Grommet
Conduit
DIN terminal
Conduit terminal
Bracket
mounting
T
U
T
U
T
U
V
T
U
V
a
b
58
60
30
30
53
55
48.5
48.5
54
56
65.5
65.5
53.5
53.5
53
55
100.5
100.5
69.5
69.5
26
28
32
34
72
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Air, Water, Oil
Dimensions: Body Material: Brass (C37), Stainless Steel
Normally closed (N.C.): VXD2140/VXD2150/VXD2260
Normally open (N.O.): VXD2142/VXD2152/VXD2262
Grommet: G
Conduit: C
Approx. 300
C
U
Approx. 280
E
E
U
VX2
VXD
G1/2
VXZ
A
T
T
Width across
flats H
VXP
M
M
IN
1
OUT
VXE
f
B
VXR
2xP
1 (IN), 2 (OUT) port
F
2.6
2 x ø8.5
I
2xP
1 (IN), 2 (OUT) port
I
VXH
VXF
J
e
d
K
F
J
a
b
L
VX3
VXA
(D)
DIN terminal: D
VCH
Conduit terminal: T
(U)
U
VDW
E
(V)
E
VQ
32
V
LVM
25
31.5
VCB
T
T
(44)
VCA
G1/2
VCL
G1/2
M
M
VCS
Cable
ø6 to ø12
VCW
2xP
F
I
F
J
1 (IN), 2 (OUT) port
J
I
2xP
1 (IN), 2 (OUT) port
(mm)
Model
N.C.
Port size
VXD2140 VXD2142
VXD2150 VXD2152
VXD2260 VXD2262
A
P
N.O.
3/8, 1/2
3/4
1
B
C
D
E
F
H
I
J
K
L
M
Grommet
T
103.5 (110.5) 24
115 (122) 29
133 (140.5) 33
30
30
35
63 19.5 3.5 27
80 19.5 4.5 27
90 22.5 4.5 32
14 44.5 29
17 51.5 37
20 60
43
34
43
47
Electrical entry
Conduit
DIN terminal
U
T
Model
N.C.
VXD2140 VXD2142
VXD2150 VXD2152
VXD2260 VXD2262
U
V
T
U
V
61
61
64
(mm)
Port size
P
N.O.
T
Conduit terminal
28 71.5 (73) 19.5 64 (65.5) 40 63.5 (65) 58.5 46.5 64 (65.5) 92
35 78 (79.5) 19.5 70.5 (72) 40 70 (71.5) 58.5 46.5 70.5 (72) 92
42 92 (93.5) 22.5 84.5 (86) 43 84 (85.5) 61.5 49.5 84.5 (86) 95
( ) denotes the value for N.O.
U
3/8, 1/2
3/4
1
Electrical entry (Built-in full-wave rectifier type)
Conduit terminal
Conduit
DIN terminal
Grommet
T
U
T
U
T
U
V
T
U
V
Bracket mounting
a
b
d
e
67.5 (69) 30 62.5 (64) 48.5 63.5 (65) 65.5 53.5 62.5 (64) 100.5 69.5 42
74 (75.5) 30 69 (70.5) 48.5 70 (71.5) 65.5 53.5 69 (70.5) 100.5 69.5 51
88 (89.5) 33 83 (84.5) 51.5 84 (85.5) 68.5 56.5 83 (84.5) 103.5 72.5 56
66
78
86
57
74
81
34 39
51 45.5
58 49.5
f
( ) denotes the value for N.O.
73
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXD21/22/23
For Air, Water, Oil
Dimensions: Body Material: Brass (C37) , Stainless Steel
Normally closed (N.C.): VXD2270/VXD2380/VXD2390
Normally open (N.O.): VXD2272/VXD2382/VXD2392
Approx. 300 U
C
Grommet: G
E
T
Width across
flats H
A
øR
OUT
B
øN
IN
8 x ø18
Q
D
F
øS
DIN terminal: D
Conduit: C
U
V
T
T
G1/2
øR
G1/2
Cable
ø6 to ø12
B
B
øR
E
31.5
E
(44)
U
Approx. 280
8 x ø18
8 x ø18
øS
F
øS
F
Conduit terminal: T
E
G1/2
øR
B
T
25
32
(U)
(V)
8 x ø18
øS
F
(mm)
Model
N.C.
N.O.
VXD2270 VXD2272
VXD2380 VXD2382
VXD2390 VXD2392
Applicable
flange
32A
40A
50A
( ) denotes the value for N.O.
Model
N.C.
N.O.
VXD2270 VXD2272
VXD2380 VXD2382
VXD2390 VXD2392
Applicable
flange
32A
40A
50A
A
B
C
D
E
F
H
N
Q
R
S
Grommet
T
U
Electrical entry
Conduit
DIN terminal
T
U
T
U
Conduit terminal
V
U
V
172.5 (180) 67.5 35 160 22.5 51.5 32 135 12 100 36 97 (98.5) 22.5 89.5 (91) 43 89 (90.5) 61.5 49.5 89.5 (91) 95
185 (192.5) 70
40 170 25 54.5 36 140 14 105 42 107 (108.5) 25.5 99.5 (101) 46 99 (100.5) 64 52 99.5 (101) 98
198 (205.5) 77.5 40 180 25 59
36 155 14 120 52 112.5 (114) 25.5 105 (106.5) 46 104.5 (106) 64 52 105 (106.5) 98
T
64
67
67
(mm)
Electrical entry (Built-in full-wave rectifier type)
Grommet
Conduit
DIN terminal
Conduit terminal
T
U
T
U
T
U
V
T
U
V
93 (94.5) 33 88 (89.5) 51.5 89 (90.5) 68.5 56.5 88 (89.5) 103.5 72.5
103 (104.5) 36 98 (99.5) 54 99 (100.5) 71 59
98 (99.5) 106 75
108.5 (110) 36 103.5 (105) 54 104.5 (106) 71 59 103.5 (105) 106 75
( ) denotes the value for N.O.
74
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Pilot Operated 2 Port Solenoid Valve
Series VXD21/22/23
For Air, Water, Oil
Replacement Parts
Solenoid
coil assembly part no.
Table (1) Model and Solenoid Coil Type
Select the coil type from
to
Voltage type
Class B
Class H
Class B
(Nil, A, B,
(Nil, A, B,
(Solenoid valve option)
(D, E, N, P)
G, H, J, L)
G, H, J, L)
DC
Class H
(Nil, A, B,
G, H, J, L)
Note)
VXD2130
Model
Rated voltage
AC (Built-in fullwave rectifier type)
AC
Coil insulation type
Table (2) Rated Voltage – Electrical Option
, and refer to “How to Order” below.
VXD21 4
5
VXD22 67 VXD23 89 DC, AC (Except VXD2130 AC/Class B)
VX02 1 N
Note 1)
5 G
Rated voltage
1
2
3
4
5
6
7
8
J
Coil insulation type
VXD21
VXD22
VXD23
Nil
H
surge
AC/ Voltage Voltage With
voltage
DC symbol
suppressor
1
100 V
2
200 V
3
110 V
AC
4
220 V
7
240 V
8
48 V
J
230 V
5
24 V
DC
6
12 V
Class B
Class H Note)
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
VX02 1 N
2
Note 1) For the AC (Class B coil) of the VXD2130, built-in
full-wave rectifier type is only applicable.
Note 2) Refer to the table (2) for the available combinations.
G - Grommet
GS- With grommet surge
With
light
S
With light and With surge
surge voltage voltage
suppressor suppressor
L
Z
With
light
With light and
surge voltage
suppressor
VX2
VXD
VXZ
DC spec. is not available.
VXE
VXP
VXR
VXH
Valve
N.C.
N.O.
Rated voltage
Electrical entry
Symbol
Nil
2
Note)
VXA
VCH
VDW
VQ
G- Grommet
voltage suppressor
Valve
N.C.
N.O.
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz
Note) Refer to the table (2) for the available combinations.
C- Conduit
VX3
Valve
VXD21
VXD22
VXD23
1
2
3
4
7
8
J
VXF
1 GR
Series
1
2
3
Valve
Symbol
Nil
Z
AC/Class B (Built-in full-wave rectifier type)
Note) DIN terminal and DC
spec. are not available.
Note 2)
Class H
L
∗ Option “S”, “Z” are not available as surge voltage suppressor is integrated into the
AC/Class B coil, as a standard.
∗ Replacement of solenoid coils:
• DC and AC coils cannot be interchanged in order to change the voltage.
• DC and AC (built-in full-wave rectifier type) coils can be interchanged in order to
change the voltage.
• All DC coil voltages are interchangeable. • All AC coil voltages are interchangeable.
Series
1
2
3
Class B
S
Electrical entry
LVM
VCA
C- Conduit
VCB
T - With conduit terminal
TS - With conduit terminal and
D - DIN terminal
DS - DIN terminal with surge
Connector
voltage suppressor
DL - DIN terminal with light
DZ - DIN terminal with
surge voltage
suppressor and light
DO - For DIN terminal
(without connector,
gasket is included.)
surge voltage suppressor
TL - With conduit
terminal and
light
TZ - With conduit
terminal, surge
voltage suppressor
and light
T - With conduit terminal
TL - With conduit terminal
D - DIN terminal
DL - DIN terminal with light Connector
DO - For DIN terminal
and light
(without connector,
gasket is included.)
∗ Refer to the table (2) for the available combinations between each electrical option
and rated voltage.
∗ A surge voltage suppressor is inegrated into the AC/Class B coil, as a standard.
For VXD2130 DC
DIN
5 G Z
connector part no.
Without electrical option
With electrical option
Rated voltage
5
6
24 VDC
12 VDC
VCS
VCW
∗ Refer to the table (2) for the available combinations between each electrical option
and rated voltage.
VX021N
VCL
GDM2A
GDM2A
Electrical option
S
L
Z
With surge voltage suppressor
With light
With light/surge voltage suppressor
∗ Refer to the table (1) for the available combinations between each electrical option (S,
L, Z) and rated voltage.
Gasket
Rated voltage
1
2
5
6
15
part no.
for DIN connector
100 VAC, 110 VAC
200 VAC, 220 VAC, 230 VAC, 240 VAC
24 VDC
12 VDC
48 VAC
VCW20-1-29-1
75
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXD21/22/23
For Air, Water, Oil
Replacement Parts
Name
plate part no.
AZ-T-
Clip
Valve model
Enter by referring to
“How to Order”.
Clip
Name plate
part no. (For N.C.)
For VXD21: VX021N-10
Solenoid coil assembly
For VXD22: VX022N-10
For VXD23: VX023N-10
Clip
part no. (For N.O.)
For VXD21: ETW-7
For VXD22: ETW-8
For VXD23: ETW-9
76
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement