Delta Electronics | RTU-DNET | deltadue® series gateways: PROFIBUS DP

BC. 02.30 DXDY/E
deltadue® series gateways:
PROFIBUS DP, DeviceNet,
CANopen, Modbus TCP
to Modbus RTU
Integrate Ascon
instrumentation lines
into your system
DX 5000 • Modbus RTU RS232/RS485
Line converter
• Modbus RTU RS485/RS485
Repeater
• Modbus RTU RS485/RS485
Line adapter
DX 5010 DeviceNet/Modbus RTU
Gateway
DX 5050 Modbus RTU/Modbus RTU
Protocol optimizer
DX 5070 PROFIBUS DP/Modbus RTU
Gateway
DY 5020 Modbus TCP/Modbus RTU
Gateway
DY 5030 CANopen/Modbus RTU
Gateway
DY 5121 WebSCADA
DX 5100 deltadue manager (4 modules)
DX 5200 deltadue manager (8 modules)
DX 5300 deltadue manager (16 modules)
DX 5400 deltadue manager (32 modules)
E
ISO 9001 Certified
DX 5000
RS232 2 x RS485 ModBus RTU converter
SLAVE
RS232
Modbus RTU
Terminals 6, 7, 8
MASTER
RS485
Modbus RTU
Side pins
4, 5
RS485
Modbus RTU
Terminals
10, 11, 12
Configuration Utility Controller Explorer or
Modbus RTU SCADA System (AutoLink)
Other
Modbus
RTU
devices
Minimal settings required for easy configuration:
• for the RS232 slave service port (terminals 6, 7, 8)
- baud rate (1200...38400 baud)
- number of characters + parity + stop bits (8N1, 8E1, 8O1, 8N2)
• for the RS485 master side port (terminals 4 and 5) and RS485 master front port (terminals 10, 11, 12)
- baud rate (1200...19200 baud) (dip switches SW1)
Up to 64 instruments with different addresses can be connected by means of the two RS485 master ports.
RS485 2 x RS485 ModBus RTU repeater
More than 32 devices,
or line > 1.2 km
RS485
Modbus RTU
SLAVE
MASTER
RS485
Modbus RTU
Terminals
2, 3, 4
RS485
Modbus RTU
Side pins
4, 5
RS485
Modbus RTU
Terminals
10, 11, 12
Other
Modbus
RTU
devices
• RS485 line repeater increases the line signal and furthermore doubles the line.
• Service port (terminals 2, 3, 4) is used as RS485 slave.
RS485 2 x RS485 ModBus RTU baud rate, parity and stop bits adapter
Modbus RTU PLC
SLAVE
RS485
Modbus RTU
Terminals
2, 3, 4
MASTER
RS485
Modbus RTU
Side pins
4, 5
RS485
Modbus RTU
Terminals
10, 11, 12
Other
Modbus
RTU
devices
• To be used when the baud rate, parity and stop bits parameters of various modules are different and cannot be changed on
the connected instruments.
• Easy configuration of the parameters on the DX5000.
2
DX 50x0
Modbus RTU, PROFIBUS, DeviceNet 2 x RS485 Modbus RTU converter, double master
SLAVE
MASTER
RS485
Modbus RTU
Terminals 2, 3, 4
PLC
RS485
Modbus RTU
Side pins 4, 5
Modbus RTU/
Profibus/
DeviceNet
RS485
Modbus RTU
Terminals
10, 11, 12
SLAVE
PRODUCER
Terminals 13, 14,15, 16
•
•
•
•
Other
Modbus
RTU
devices
Two masters can simultaneously access the instrumentation connected on Modbus RTU networks.
One of the two masters must be Modbus RTU.
The second master can be PROFIBUS or DeviceNet or Modbus RTU; the DX 50x0 converts these protocols to Modbus RTU.
For example: the RS232 or RS485 service ports of DX 50x0 can be connected to an Ascon AutoLink self configuring SCADA or to a local
operator panel; the slave Fieldbus port can be connected to any PLC using PROFIBUS, DeviceNet or Modbus RTU protocols.
COLMEC extrusion line with Siemens PLC. Control and data acquisition are made by using deltadue series (D1, D8 and D9).
A gateway DX 5370 is installed to perform PROFIBUS-Modbus RTU data exchange and manager function for 16 instruments.
DX 5x00
Manager for up to 32 devices (deltadue and/or gammadue X1, X3, Q1, Q3)
MASTER
RS485
Modbus RTU
Side pins 4, 5
RS485
Modbus RTU
Terminals
10, 11, 12
• Memorization of the configuration and operator parameters of up to 32 connected instruments in Ascon gammadue and deltadue series.
• Automatic configuration and parameterization of the new instrument in case of failure (hot swapping).
• Instrument configurations and parameters can be downloaded to the DX 5x00 when instruments are not yet installed (off-line
configuration). Automatic configuration and parameterization of the new instruments when connected.
3
DY 5020
Modbus TCP 2 x RS485 Modbus RTU converter
SERVER
MASTER
RS485
Modbus RTU
Terminals
2, 3, 4
RS485
Modbus RTU
Side pins
4, 5
RJ45
Modbus TCP SCADA
System (AutoLink)
Other
Modbus
RTU
devices
Ethernet/
Internet
• Connects Ascon instrumentation in the gammadue, deltadue and sigmadue series, with Modbus RTU protocol to a PLC or SCADA with
Modbus TCP protocol via an Ethernet network (e.g. the factory LAN) or the web. Can also connect any other device with Modbus RTU
protocol.
• Two Modbus TCP / Modbus RTU conversion modes are available
- Routing (transparent mode)
- Natting (conversion using a configurable table)
• The network identifies the DY5020 by means of its IP.
DY 5030
CANopen 2 x RS485 Modbus RTU converter
PRODUCER
MASTER
RS485
Modbus RTU
Terminals 2, 3, 4
Other
Modbus
RTU
devices
RS485
Modbus RTU
Side pins 4, 5
sigmadue CPU
CANopen
Terminals
13, 14, 15, 16
• Allows connection of Modbus RTU instrumentation to CANopen networks.
• DY5030 is not only a protocol converter but also supports the automatic PDO “change of status” transmission and the management of the
data consistency information. The DY5030 is a real CANopen node.
• Main features include:
- analogue and digital SDOs
- 2 analogue RPDOs and one digital RPDO
- 2 analogue TPDOs and one digital TPDO transmitted on
• Remote request
- Event (dead band for the analogue units and mask for the digital units)
- Sync
• Data consistency check bit for each PDO
• Mask for the writing of the digital SDOs and RPDOs
4
DY 5121
WebSCADA and Modbus TCP RS485 Modbus RTU converter
Other
Modbus
RTU
devices
RS485
Modbus
RTU
MASTER
RJ12
Modbus TCP SCADA System 1
(AutoLink)
Ethernet/
Internet
RJ45
SERVER
Modbus TCP SCADA System 2
(AutoLink)
Web Browser 2
Web Browser 1
• Performs simultaneous multi client Modbus TCP / Modbus RTU conversion.
• Allows configuration of HTML pages for management of Modbus RTU instruments by using any web browser.
• The WebSCADA function includes:
- Templates
- Binding (data transfer)
- 30 pages with 20 variables each
- 64 alarms (e-mail and SMS with external analogue, GSM or GPRS modem)
- Log file (.csv) of 64 variables, can be sent periodically via e-mail
- Graphics (if JAVA is installed).
A further example of COLMEC extrusion line.
5
DY 5020 + DX 5xx0
AutoLink Modbus TCP and PLC together as 2 different masters
RS485
Modbus RTU
master
DY terminals
2, 3, 4
RS485
Modbus RTU
slave
DX terminals
2, 3, 4
MASTER
RS485
Modbus RTU
Side pins 4, 5
RJ45
Modbus TCP SCADA
System (AutoLink)
Other
Modbus
RTU
devices
RS485
Modbus RTU
Terminals
10, 11, 12
Terminals
13, 14, 15, 16
Ethernet/
Internet
Modbus RTU,
PROFIBUS,
DeviceNet
PLC
• The combined use of one DY5020 and one DX5xx0 allows the simultaneous use of a Modbus TCP SCADA (e.g.: Ascon AutoLink) and a PLC
(PROFIBUS or DeviceNet or Modbus RTU).
• The SCADA and the PLC can also share the same Modbus RTU instrumentation.
SigmaPAC + DY 5030
SigmaPAC with Modbus RTU I/O in CANopen network
PRODUCER
MASTER
sigmadue CPU
RS485
Modbus RTU
Terminals 2, 3, 4
RS485
Modbus RTU
Side pins 4, 5
sigmaPAC
CANopen
sigmadue CANopen I/O
Terminals
13, 14, 15, 16
• Allows the use of Ascon Modbus RTU gammadue and deltadue instruments as I/Os of the sigmadue CPU.
6
Other
Modbus
RTU
devices
Technical data
DX Line
Features
Functions
Electrical connections
Description
Manager
OFF line configuration and parameterization.
Backup of the configuration and parameter data of the connected modules.
Hot swapping, automatic configuration and parameterization of the replaced modules
Gateway
Network adapter for PROFIBUS DP, DeviceNet, Modbus RTU
and RS485/RS232 line converter
Instruments
RS485 Modbus protocol master replicated on the terminal connectors (max. 19200 baud)
Bus
Service
Communications
ports
RS485, RS232 Modbus protocol slave, isolated (max. 38400 baud)
RS485 Modbus protocol slave, isolated (max. 57600 baud)
Fieldbus
PROFIBUS DP slave
DP control: SPC3
DP interface: RS485 isolated, max. 12 Mb/s
CAN 2.0b, isolated, max. 1Mb/s
DY Line
Features
Functions
- templates
- binding (data transfer)
- 30 pages of 20 variables
WebSCADA - 64 alarms (e-mail and SMS with external analogue modem, GSM or GPRS)
- 64 variables log file (.csv), can be transmitted periodically by e-mail
- graphics (if JAVA is installed)
Gateway
Communications
ports
Electrical connections
Description
From CANopen or Modbus TCP to Modbus RTU
Instruments
RS485 Modbus protocol master replicated on connector A (max. 115200 baud)
Bus
Service
RS232 standard (only for instrument configuration)
Fieldbus
CAN 2.0b, isolated, max. 1Mb/s
Ethernet 10/100 Mbaud, RJ45 female connector
Common features
Features
at env. 25°C
Description
Power supply
(PTC protected)
24Vac (-25...+12%) 50/60Hz and
24Vdc (-15...+25%)
Safety
EN61010-1 (IEC1010-1), installation class 2 (2.5kV)
pollution class 2, instrument class II
Power consumption: 3W max.
Electromagnetic
General
Compliance to the CE standards
characteristics compatibility
UL and cUL
File E176452
approval
Protection
Terminal strip IP20
Dimensions
Pitch: 22.5 mm - height: 99 mm - depth 114.5 mm
Weight
200 g max.
7
Ordering codes
ASCON spa
Via Falzarego, 9/11
20021 Baranzate
(Milano) Italy
Tel. +39 02 333 371
Fax +39 02 350 4243
http://www.ascon.it
sales@ascon.it
Line
Model:
DX
Basic model
5
B
C
•
•
Accessories
0
_
0
0
0
0
•
No. of instruments backed up
Fieldbus communications
Instructions handbook
Number of instruments to be backed up
0
4
8
16
32
B
0
1
2
3
4
Fieldbus communications
None [1]
DeviceNet
RS 485 Modbus/Jbus
Profibus DP slave
C
0
1
5
7
F
0
Instructions handbook
Italian-English (standard)
If not differently specified the controller
will be supplied with standard version
Model: DX 5000-0000
[1] The instrument perfoms the hardware convertion RS232/485 only for the standard Modbus RTU protocol.
ASCON FRANCE
2 bis, Rue Paul Henri Spaak
ST.THIBAULT DES VIGNES
F-77462 LAGNY SUR MARNE Cedex
Tél. +33 (0) 1 64 30 62 62
Fax +33 (0) 1 64 30 84 98
www.ascon.fr
ascon.france@ascon.fr
AGENCE EST
Tél. +33 (3) 89 76 99 89
Fax +33 (3) 89 76 87 03
AGENCE SUD-EST
Tél. +33 (0) 4 74 27 82 81
Fax +33 (0) 4 74 27 81 71
ASCON
CORPORATION
DY Line
Line
Model:
DY
Basic model
5
B
C
•
•
1884 East Fabyan Parkway
Batavia, Illinois 60510
Tel. +1 630 482 2950
Fax +1 630 482 295
www.asconcorp.com
info@asconcorp.com
Accessories
D
_
0
8
0
0
•
Function
Housing type
Instructions handbook
B
0
0
1
Function
Modbus TCP/RTU
CANOpen/Modbus RTU [2]
WEB server + Modbus TCP/RTU
C
2
3
2
D
0
1
Housing type
deltadue series
Standard 4 DIN
Instructions handbook
English (standard)
If not differently specified the controller
will be supplied with standard version
Model: DY 5020-0800
[2] Not available when D = 1.
F
8
WORLDWIDE NETWORK OF DIRECT
SALES CENTRES, DISTRIBUTORS
AND VARs
Europe
Belgium, Croatia, Czech Rep., Denmark,
Esthonia, Finland, France, Germany,
Great Britain, Greece, Holland, Ireland,
Norway, Poland, Portugal, Romania,
Russia, Slovakia, Slovenia, Spain,
Sweden, Switzerland, Turkey, Ukraine
Americas
Argentina, Brazil, Canada, Chile,
Colombia, Ecuador, Paraguay, Peru,
Urugay, Venezuela
Rest of the world
Algeria, Australia, China, Egypt, Hong
Kong, India, Indonesia, Iran, Israel,
Malaysia, Marocco, New Zeland,
Pakistan, Saudi Arabia, Singapore,
Taiwan, Thailand, Tunisia, S
outh Africa & South East Africa, UAE
Mechanical dimensions
99 mm
3.9 in
22.5 mm
0.89 in
114.5 mm
4.5 in
6.3 mm
0.25 in
The specifications in this document may therefore be changed without notice - All trademarks mentioned int this document belong to their respective owners