CSA American | GT-505-NI | PSS EML0710 A-(en) - FOXBORO

Product Specifications
11.2011
PSS EML0710 A-(en)
244LD Intelligent Buoyancy Transmitter with Torque Tube
for Liquid Level, Interface and Density
The intelligent transmitter 244LD is designed to perform continuous measurements for liquid level, interface or density of liquids in the process of all industrial applications. The measurement is based on the proven Archimedes buoyancy principle and thus extremely robust and durable. Measuring values can be transferred analog and digital. Digital
communication facilitates complete operation and configuration via PC or control system. Despite extreme temperatures, high process pressure and corrosive liquids, the 244LD measures with consistent reliability and high precision.
It is approved for installations in contact with explosive atmospheres. The 244LD combines the abundant experience
of FOXBORO ECKARDT with most advanced digital technology.
FEATURES
• Communication HART, PROFIBUS PA or
FOUNDATION Fieldbus
• Conventional operation with local keys
• Easy adaptation to the measuring point
without calibration at the workshop
• Backdocumentation of measuring point
• Continuous self-diagnostics
• Configurable safety value
• Software lock for local keys and
reconfiguration
• Approved for SIL applications
•
•
•
•
•
•
•
•
Simulation of analog output for loop-check
Local display in %, mA or physical units
Signal noise suppression by Smart Smoothing
Linear or customized characteristic
Process temperature from –196 °C to +400 °C
Materials for use with aggressive media
Micro sintermetal sensor technology
Separate mounting of sensor and amplifier with
remote amplifier mounting kit
2
244LD
TECHNICAL DATA
Data refer to the sensor material Type 316L (1.4404)
Explosion protection certificates must be observed!
Input / Output
Measuring ranges . . . . . . . . 50 mm to 50 m
upper and lower range value
continuously adjustable
Standard lenghts of
Displacer (104DE) . . . . . . . . 350 .. 3000 mm, 14 .. 120 in;
further lenghts on request
Weight of displacer 1) . . . . . . max. 25 N
Measuring span . . . . . . . . . . 2... 20 N contin. adjustable
(to 1 N on request)
Span ratio
Turn-down . . . . . . . . . . . . . . 1:1 .. 1:10 (1:20 on request)
Accuracy 2) . . . . . . . . . . . . . ± 0.2 % ; increased accuracy
with customized adjustment
Transfer function . . . . . . . . . linear or customized with up
to 32 setpoints 3)
Configuration
- with local push buttons and LCD
- Digital (see communication ...)
Local display . . . . . . . . . . . . LCD 5 digits, configurable in
%, mA or phys. units
Load . . . . . . . . . . . . . . . . . RBmax = (US – 12V) / 23 mA
Communication HART
Connection . . . . . . . . . . . . . Two-wire system
Supply voltage US: . . . . . . . . 12 .. 42 V DC 6), VSS ≤1%
Current sink . . . . . . . . . . . . . max. 23 mA
Signal range . . . . . . . . . . . . 4 .. 20 mA
Operating range. . . . . . . . . . 3.8 .. 21 mA
Digital communication . . . . . HART Protocol, 1200 Baud
Hand held terminal . . . . . . HHT 991
PC Software . . . . . . . . . . . PC20 / ABO991
Hardware . . . . . . . . . . . . . HART Modem MOD991 for PC
Min. load . . . . . . . . . . . . . . 250 Ω
Failure handling
Substitute value. . . . . . . . . last value or safety value
Safety value . . . . . . . . . . . 3.6 ... 23 mA, adjustable
Reset substitute value . . . . automatically or manual
Select messages. . . . . . . . Internal calibration failed,
Pressure peaks ≥ 150 %,
Data access failed,
Over range ≥ 110 %,
Ambient temp. out of limits,
Process temp. out of limits,
Measuring range invalid
1)
2)
3)
4)
5)
6)
For measurement of interface or density:
weight ≤ 25 N + buoyant force at lowest density
Accuracy acc. ANSI / ISA - S51.1 - 1979
Customized not with FoxCom
Reset of substitute value after pressure peaks automatically
With explosionproof device 9 .. 24 V
With explosionproof device 12 .. 30 V
PSS EML0710 A-(en)
Communication PROFIBUS PA
Connection . . . . . . . . . . . . . twisted and shielded two wire
cable acc.to recommendation
based on IEC 1158-2
Supply voltage US: . . . . . . . . 9 .. 32 V DC 5), VSS ≤1%
Operating current . . . . . . . . . 10.5 mA ± 0.5 mA
(base current)
Digital communication . . . . . PROFIBUS PA protocol, acc.
to class B profile, EN 50170
and DIN 19245 part 4
Signal amplitude. . . . . . . . ± 8 mA
Fault current . . . . . . . . . . . ≤ 13 mA
Operating values . . . . . . . according to IEC 1158-2
Bus connection. . . . . . . . . Fieldbus interface based on
IEC 1158-2
Power supply . . . . . . . . . . Power supply is achieved dependant on the application by
means of segment coupler
GSD file . . . . . . . . . . . . . . the actual file can be downloaded from our homepage
Configuration
Software. . . . . . . . . . . . . . PC20 for PC
Hardware . . . . . . . . . . . . . PC- or PCMCIA-interfaces
from Softing
Control systems . . . . . . . . PROFIBUS PA compatible
Failure handling
Substitute value. . . . . . . . . last value or safety value
Safety value . . . . . . . . . . . adjustable -110 .. +110 % of out
Reset substitute value . . . . automatically or manual
Select messages . .
Internal calibration failed,
Sensor value out of range
Memory access failed
Measuring range out of sensor range
Ambient temp. out of limits,
Process temp. out of limits,
Measuring range invalid
PSS EML0710 A-(en)
Communication FOUNDATION Fieldbus
Connection . . . . . . . . . . . . . twisted and shielded two wire
cable acc.to recommendation
based on IEC 1158-2
Supply voltage US: . . . . . . . . 9 .. 32 V DC 1), VSS ≤1%
Operating current . . . . . . . . . 10.5 mA ± 0.5 mA
(base current)
Digital communication . . . . . FF specification Rev. 1.4,
Link-Master (LAS)
Signal amplitude. . . . . . . . ± 8 mA
Fault current . . . . . . . . . . . ≤ 13 mA
Operating values . . . . . . . according to IEC 1158-2
Bus connection. . . . . . . . . Fieldbus interface based on
IEC 1158-2
Power supply . . . . . . . . . . Power supply is achieved dependant on the application by
means of segment coupler
File . . . . . . . . . . . . . . . . . the actual file can be downloaded from our homepage
Configuration
Software. . . . . . . . . . . . . . National Instruments
NI-FBUS Configurator
Hardware . . . . . . . . . . . . . FBUS interfaces from National Instruments (AT-FBUS
and PCMCIA- FBUS)
Control systems . . . . . . . . FOUNDATION Fieldbus H1
compatible
Failure handling
Substitute value. . . . . . . . . last value or safety value
Safety value . . . . . . . . . . . adjustable -110 .. +110 % of out
Reset substitute value . . . . automatically or manual
Select messages . .
Internal calibration failed,
Sensor value out of range
Memory access failed
Measuring range out of sensor range
Ambient temp. out of limits,
Process temp. out of limits,
Measuring range invalid
1)
2)
3)
4)
5)
6)
With explosionproof device 9 .. 24 V
Not with all materials - see Table of Comparison of Materials page 7
Ambient temperature must not exceed 50°C at measuring module
housing, when process medium or heating of medium exceed 300°C
–50 °C on request
Display invisible at T < –30 °C
For max. measuring span
244LD
3
Operating conditions 2)
Process temperature . . . . . . –196 °C ... +400 °C
Pressure rating
acc. to DIN . . . . . . . . . . . . PN 16, 40, 63, 100, 160, 250
acc. to ANSI . . . . . . . . . . . Class 150, 300, 600, 900, 1500
Ambient temperature 3) 4)
without indicator . . . . . . . . –40 °C ... +85 °C
with LCD indicator . . . . . . . –40 °C ... +70 °C 5)
Relative humidity . . . . . . . . . ≤ 100%
Condensation . . . . . . . . . . . permitted
Transportationstorage temperature. . . . . . . –50 °C ... +85 °C
Protection . . . . . . . . . . . . . . IP 66 (acc. DIN 40 050)
The device can be operated at a class D2 location in
accordance with DIN IEC 654, part 1.
Operation condition effects
Ambient temperature . . . . . . –10 °C ... +70 °C
Zero . . . . . . . . . . . . . . . . ≤ 0.1 % / 10 K 6)
Span . . . . . . . . . . . . . . . ≤ 0.07 % / 10 K
Total
max. sp.
measured value
)% / 10K
± 0.07
adjusted sp.
adjusted sp.
(sp. = measuring span)
(0.1
< -10 °C / > +70 °C . . . . . . twice the value
Process temperature . . . . . . ≤ 0.1 % / 10 K 6)
Operating pressure . . . . . . . no influence (vakuum resistant)
Transitional behavior
Dynamic behavior
Damping (90%-time) . . . . . 0 ... 32 s
Switch-on time . . . . . . . . . 7 s
Step response (63%-time)
with damping 0 s . . . . . . . . 250 ms
Update rate . . . . . . . . . . . . . 10/s
Long term stability . . . . . . . . ≤ 0.2 % / 6 months at 20°C 6)
Noise suppression
Common mode voltage . . . ≤ AC 250 Veff
Common mode rejection . . 120 dB
Series mode rejection . . . . 50 dB
Mains synchronization. . . . 50 Hz / 60 Hz
Filter . . . . . . . . . . . . . . . . . Smart Smoothing
4
244LD
PSS EML0710 A-(en)
Material,
Pressure Rating & Contact Face,
Mounting Direction
see Model Codes
Electrical connection
Cable entry thread . . . . . . . . M20x1.5 or 1/2-14 NPT
Cable gland and screwed sealing plug have to be ordered
separately under model code BUSG ...
Material Amplifier housing . . Aluminum
(Alloy No. GD-Al Si 12),
Polyurethan coated
For equipment in Ex d version, 1 screwed sealing plug
made of stainless steel is included in delivery.
Screw terminals . . . . . . . . . . wire cross-section up to 2.5 mm²
Test sockets . . . . . . . . . . . . Ø 2 mm
For Sour Gas applications acc. to NACE Standard MR-0175-95:
Wafer body . . . . . . . . . . . . 316L (1.4404)
Torque tube . . . . . . . . . . . Hastelloy C or Inconel 600
see Model Codes
Electromagnetic compatibility EMC
Mounting
Mounting method . . . . . . . . . sandwich mounted
acc. to DIN . . . . . . . . . . . . DN 80, DN 100
acc. to ANSI . . . . . . . . . . . 3 inch, 4 inch
see Model Codes
Accessories for separate
mounting of amplifier . . . . . . remote amplifier mounting kit
Length of cable . . . . . . . . . . 3 m / 10 m
Operating conditions . . . . . . industrial environment
Immunity according to
EN 61326 (3/2002) . . . . . . fulfilled
Emission according to
EN 61326 (3/2002) . . . . . . fulfilled
EN 55011, May 2000,
Group 1, Class A. . . . . . . . fulfilled
EN 50081-2. . . . . . . . . . . . fulfilled
NAMUR recommendation Ne21 Status Aug.1998 fulfilled
SAFETY REQUIREMENTS
CE Label
Electromagnetic
compatibility . . . . . . . . . . . . . 2004/108/EC fulfilled
Explosion protection acc. to ATEX . . . 94/9/EC
Safety
Weight
Transmitter . . . . . . . . . . . . . see table page 7
Displacer . . . . . . . . . . . . . . . see table page 10
244LD versions ...
According to EN 61010-1
(resp. IEC 1010-1) . . . . . . . . safety class III
Internal fuses . . . . . . . . . . . . none (or not replaceable by
customer)
External fuses . . . . . . . . . . . Limitation of power supplies
for fire protection have to be observed due to EN 61010-1,
appendix F (rsp. IEC 1010-1)
... with Heating Jacket
... for Left Hand or
Right Hand mounting
M S 4 1 -...
L H
/ 1
0 m
Ø 4 0 ..6 4 m m
3 m
R H
*
*
... with Remote Amplifier Mounting Kit
PSS EML0710 A-(en)
244LD
5
Electrical classification ATEX 2) 3)
intrinsic safe:
AI 408
AI 428
mounted with:
AI 432
AI 432 A
HART / FoxCom electronics 1)
PA/FF electronics
II 2 G EEx ia/ib IIC T4
II 2 G EEx ia IIC T4/T6
Wafer body 244LD (no gap redu. bush) II 2 G EEx ia IIC T6/T4
Wafer body 244LD (no CS2)
II 1/2 G EEx ia IIC T6/T4
explosion-proof:
AD 931
Housing for PA-FF-HART-FoxCom 1)
II 2 G EEx d IIC T6
mounted with:
AD 432
Wafer body 244LD (no gap redu. bush) II 2 G EEx d IIC T6
AD 432 A
Wafer body 244LD (no CS2)
II 1/2 G EEx d IIC T6
intrinsic safe and auxilliary protection:
AID421
Housing for PA-FF-HART-FoxCom 1)
II 2 G EEx ia d IIC T6
mounted with:
AD 432
Wafer body 244LD (no gap redu. bush) II 2 G EEx d IIC T6/T4
AD 432 A
Wafer body 244LD (no CS2)
II 1/2 G EEx d IIC T6/T4
Zone 2:
AN 408
HART/FoxCom electronics 1)
II 3 G EEx ia/ib IIC T4
AN 428
PA/FF electronics
II 3 G EEx ia IIC T4/T6
mounted with:
AN 432
Wafer body 244LD (no gap redu. bush) II 3 G EEx ia IIC T6/T4
PTB 01 ATEX 2168
PTB 01 ATEX 2156
Zone 1
Zone 1
PTB 01 ATEX 2177
PTB 01 ATEX 2177
Zone 1
Zone 0
PTB 02 ATEX 1025 X
Zone 1
PTB 02 ATEX 1142
PTB 02 ATEX 1142
Zone 1
Zone 0
PTB 04 ATEX 2011 X
Zone 1
PTB 02 ATEX 1142
PTB 02 ATEX 1142
Zone 1
Zone 0
Manufacturer’s Declaration
Manufacturer’s Declaration
Zone 2
Zone 2
PTB 01 ATEX 2177
Zone 2
Further National certificates
International Certificates
- Overfill protection according to WHG
FM Certification
Intrinsically Safe / I, II, III /1 / ABCDEFG / T4 Ta=85°C
Nonincendive / I /2 / ABCD /T4 Ta=85°C
Special Protection / II /2 /FG /T4 Ta=85°C
Special Protection / III /1,2 /T4 Ta=85°C
Type 4X
Entity Parameters:
Vmax=30 V, Imax=150 mA, Ci=2,45 nF, Li=0,14 mH
- Bauteileprüfung von Wasserstand-Stetigreglern
(VdTÜV Wasserstand 100)
CSA Certification *
RUSSIAN “Intrinsic safety”
RUSSIAN “Explosionproof”
Belarus - Certificate Number 2176
- Further protection types of on request -
*
1)
2)
3)
In preparation
Electrical data see EC Certificates of Conormity
With appropriate order only
National requirements have to be observed
6
244LD
PSS EML0710 A-(en)
CONNECTIONS, OPERATIONAL ELEMENTS
1
9
1 5
1 4
1 6
4
3
6
5
1 7
6
2
1 3
1 2
7
5 0
1 0
1
2
3
4
5
6
7
9
Cover for terminal compartment
Cable gland
Plug, interchangable by Pos. 2
External ground connection
Internal ground connection
Terminals ( + / - )
Test sockets ∅ 2 mm integrated in terminals
Security lock for EEx d version
10
12
13
14
15
16
17
50
Cover for amplifier housing (with local display)
Local key for lower range value / zero
Local key for upper range value / damping
LCD indicator
Measuring variable
Engineering unit
Bottom housing cover
Overvoltage protection (if present)
PSS EML0710 A-(en)
7
244LD
Comparison of Material
Code
St 35
St 35.8 III
C 21
C 22.8
X6 CrNiMoTi 17 12 2
X2 CrNiMo 17 13 2
X2 CrNiMo 18 14 3
X5 CrNiMo 17 13 3
NiMo 16 Cr 15 W
NiCr 15 Fe
GD - AlSi 12
WNr
1.0308
1.0305
1.0432
1.0460
1.4571
1.4404
1.4435
1.4436
2.4883
2.4816
3.2582.05
DIN
2391
17 175
−
EN 10 273
Remarks
equivalent to
ASTM A 519 - 1020
VdTÜV - Wbl. 399 (for ANSI flanges only)
VdTÜV - Wbl. 350/3
ASTM A 105
ASTM A 576 - 1020
~ ASTM Typ 316Ti
17 440
17 744
17 742
17 007
ASTM Typ 316L
equivalent to Hastelloy C-276 VdTÜV - Wbl. 400
Inconel 600 VdTÜV - Wbl. 305
Al - Diecasting
UNS N 12 276
UNS N 06600
Service Limits
Nominal pressure
PN 16
DIN 2633
PN 40
DIN 2635
PN 63
DIN 2636
PN 100
DIN 2637
PN 160
DIN 2638
PN 250
DIN 2628
Class 150
Class 300
Class 600
Class 900
Class 1500
–60
...
–102)
12
30
48
73
120
187
14
38
76
114
191
–10
...
120
16
40
64
98
160
250
16
46
92
139
231
C22.8 (~ A105)
316 / 316L (1.4404 / 1.4571) /Hastelloy C 1)
Max. operating pressure in bar at temperature in °C
–196 –60
–10
200
250
300
350
...
...
...
100
200
300
400
–602) –10
50
13
11
9
8
16
12
9
7
35
32
27
21
40
35
32
28
25
50
45
39
30
64
57
51
45
33
80
70
60
48
100
95
80
70
64
130
112
96
90
160
142
128
113
97
200
175
150
140
250
230
200
177
162
14
12
10
8
19
18
16
13
10
6
43
41
38
37
49
42
35
31
27
87
83
77
73
99
84
71
63
58
131
123
116
110
148
126
107
94
87
219
206
180
145
248
211
178
158
145
Table of Weights
Weight [kg]
Transmitter with wafer body and
measuring module housing
DIN PN
16 ... 160
250
12.5
12.5
13.5
13.5
DN 80 / 3 inch
DN 100 / 4 inch
ANSI Class
300 / 600
900
12.5
13.5
150
1500
16
18.5
Table of versions (for dimensions c, d, g see drawing on page 12)
Version
DIN
PN
16
40
63
100
160
250
Form of Sealings
Type E,
Type N,
Type L,
DIN 2526 DIN 2512 DIN 2696
:
:
:
:
:
x
:
:
:
:
x
:
:
x
DN 80 / 3 inch
DN 100 / 4 inch
c
d
g
c
d
g
140
82
138
160
102
162
RF
ANSI
1)
2)
150
300
600
900
1500
Raised Face (RF),
ANSI B16.5,
Ring Joint Face (RJF),
ANSI B16.5
With material wafer body Hastelloy C: max. PN 100 / Class 600
On request
RJF
RF
RJF
140
140
82
140 147
162
160
102
162
174
206
8
244LD
PSS EML0710 A-(en)
MODEL CODES 244LD
Intelligent Buoyancy Transmitter
244LD
with Torque Tube
Wafer Body Material (Process wetted):
Carbon Steel 1.0460 (~A 105),
application from –10°C to +350°C . . . . . . . . . -K
1.4404 equivalent to 316L / 1.4435, application from
–60°C to +400°C (material is 1.4435 when Wafer
Body Pressure Rating codes H1and H2 selected) . . -S
1.4404 equivalent to 316L / 1.4435, application from
–196°C to +400°C (material is 1.4435 when Wafer
Body Pressure Rating codes H1and H2 selected) . . -U
1.4404 equivalent to 316L / 1.4435, application from
–60°C to +500°C (material is 1.4435 when Wafer
Body Pressure Rating codes H1and H2 selected) . . -T
Duplex - 1.4462, application from –10°C to +280°C
(no PED Certification) . . . . . . . . . . . . . . . . -N
Inconel 625 - 2.4856, application from –10°C to +450°C
(no PED Certification) . . . . . . . . . . . . . . . . -A
Inconel 825 - 2.4858, application from –10°C to +450°C
(no PED Certification) (p) . . . . . . . . . . . . . . -I
Hastelloy C , application from –196°C to +400°C. . . . -C
Torque Tube Material (Process wetted):
1.4404 equivalent to 316L . . . . . . . . . . . . . . . . . . . S
Hastelloy C . . . . . . . . . . . . . . . . . . . . . . . . . . C
Inconel 600 - 2.4816 . . . . . . . . . . . . . . . . . . . . . . I
Monel K500- 2.4375 . . . . . . . . . . . . . . . . . . . . . M
Wafer Body Flange Size (Nominal size):
DN70 (available with Wafer Body Material S, U, T
and Torque Tube Material S and C) . . . . . . . . . . . . . . .
DN80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DN100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-Inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wafer Body Pressure Rating & Contact Face
PN40 (PN16 to PN40) B1/B1 (Contact Face DIN EN 1092-1) . (a) .
PN250 (PN16 to PN250) B2/B2 (Contact Face DIN EN 1092-1)
(Draft DIN EN 1092-1:2005-04). . . . . . . . . . . . . . . (a) .
PN250 (PN16 to PN250) D/C (Contact Face DIN EN 1092-1)
(Draft DIN EN 1092-1:2005-04) . . . . . . . . . . . . . . (a)(r).
PN250 (PN16 to PN250) D/D (Contact Face DIN EN 1092-1)
(Draft DIN EN 1092-1:2005-04). . . . . . . . . . . . . . . (a) .
PN250 (PN16 to PN250) F/F (Contact Face DIN EN 1092-1)
(Draft DIN EN 1092-1:2005-04). . . . . . . . . . . . . . . (a) .
PN250 (PN16 to PN250) F/E (Contact Face DIN EN 1092-1)
(Draft DIN EN 1092-1:2005-04) . . . . . . . . . . . . . . (a)(s).
PN250 (PN16 to PN250) L/L (Contact Face DIN 2696) . . . . (a) .
PN400 L/L Lense (Contact Face DIN 2696) . . . . . . . . . (k) (n)
PN500 L/L Lense (IG-Norm High Pressure Version) . . . . (i) (n).
ANSI Class 150 RF/RF . . . . . . . . . . . . . . . . . . . (b) .
ANSI Class 900 (300/600/900) RF/RF . . . . . . . . . . . . (b) .
ANSI Class 1500 RF/RF . . . . . . . . . . . . . . . . . . . (b) .
ANSI Class 150 SF/SF. . . . . . . . . . . . . . . . . . . . (b) .
ANSI Class 900 (300/600/900) SF/SF . . . . . . . . . . . . (b) .
ANSI Class 1500 SF/SF . . . . . . . . . . . . . . . . . . . (b) .
ANSI Class 150 RJF/RJF . . . . . . . . . . . . . . . . . . (b) .
ANSI Class 900 (300/600/900) RJF/RJF . . . . . . . . . . . (b) .
ANSI Class 1500 RJF/RJF . . . . . . . . . . . . . . . . . . (b) .
ANSI Class 300 to 1500, Form LF/LM . . . . . . . . . . . . (b) .
ANSI Class 300 to 1500, Form LF/LF . . . . . . . . . . . . . (b) .
ANSI Class 300 to 1500, Form LG/LT. . . . . . . . . . . . . (b) .
ANSI Class 300 to 1500, Form LG/LG . . . . . . . . . . . . (b) .
(continued on next page)
010611
.
.
.
.
.
0
1
2
3
4
. . . . B1
. . . . B2
. . . . DC
. . . . DD
. . . . FF
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
FE
L1
H1
H2
R1
R2
R3
S1
S2
S3
J1
J2
J3
LM
LF
LT
LG
PSS EML0710 A-(en)
244LD
MODEL CODES 244LD (continued)
(Wafer Body Pressure Rating & Contact Face)
ANSI Class 150, Form SG/ST . . . . . . . . . . . . . . . . (b) . . . . . GT
ANSI Class 300 to 1500, Form SG/ST . . . . . . . . . . . . (b) . . . . . ST
ANSI Class 150, Form SG/SG . . . . . . . . . . . . . . . . (b) . . . . . GG
ANSI Class 300 to 1500, Form SG/SG . . . . . . . . . . . . (b) . . . . . SG
Wafer Body Mounting Direction: (Amplifier to body)
Right Hand mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R
Right Hand mounted with heating jacket - connecting flanges B1 / DN15, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . A
- connecting flanges B1 / DN25, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . B
- connecting flanges B2 / DN15, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . C
- connecting flanges B2 / DN25, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . D
- connecting flanges RF/SF, 1/2 in, Class 300 . . . . . . . . . . . (m) (o). . . . . E
- connecting flanges RF/SF, 1 in, Class 300 . . . . . . . . . . . (m) (o). . . . . F
- connecting flanges RJF, 1/2 in, Class 300 . . . . . . . . . . . (m) (o). . . . . G
- connecting flanges RJF,
1 in, Class 300 . . . . . . . . . . . (m) (o). . . . . H
Left Hand mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L
Left Hand mounted with heating jacket - connecting flanges B1 / DN15, PN40 (DIN EN 1092-1) . . . . . . (m) (o) . . . . M
- connecting flanges B1 / DN25, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . N
- connecting flanges B2 / DN15, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . O
- connecting flanges B2 / DN25, PN40 (DIN EN 1092-1) . . . . . . (m) (o). . . . . P
- connecting flanges RF/SF, 1/2 in, Class 300 . . . . . . . . . . . (m) (o). . . . . S
- connecting flanges RF/SF, 1 in, Class 300 . . . . . . . . . . . (m) (o). . . . . T
- connecting flanges RJF, 1/2 in, Class 300 . . . . . . . . . . . (m) (o). . . . . U
- connecting flanges RJF,
1 in, Class 300 . . . . . . . . . . . (m) (o). . . . . V
Version:
Base VERSION - TRANSSTAR- (244LD). . . . . . . . . . . . . . . . . . . . . . . . . B
Base VERSION - LEVELSTAR- (244LD) . . . . . . . . . . . . . . . . . (f)(v) . . . . . N
Base (B) + Displacer (244LD + 204DE) . . . . . . . . . . . . . . . . . . . . . . . . . . S
Base (N) + Displacer (244LD + 204DE) . . . . . . . . . . . . . . . . . . (f)(v) . . . . . T
Base (B) + Displacer + Displacer Camber + Flange combination + Flange
(244LD + 204DE + 204DC + 204FK + 204BCF) . . . . . . . . . . . . . (h). . . . . . C
Base (N) + Displacer + Displacer Camber + Flange combination + Flange
(244LD + 204DE + 204DC + 204FK + 204BCF) . . . . . . . . . . . . (f)(v)(h) . . . . D
Cable Entry:
M20x1.5 without cable gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M
1/2-14 NPT without cable gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N
Communication:
HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PROFIBUS-PA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FOUNDATION Fieldbus H1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Classification:
ATEX intrinsic safe Zone 0, IIC T4 (HART) . . . . . . . . . . . . . . . . . . . . . . . (d). . . .
ATEX Intrinsic safe Zone 0, IIC T6 (HART, PROFIBUS or FOUNDATION Fieldbus) . . . (d). . . .
ATEX intrinsic safe Zone 1, IIC T4 (HART) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ATEX intrinsic safe Zone 1, IIC T6 (HART, PROFIBUS or FOUNDATION Fieldbus) . . . . . . . .
ATEX intrinsic safe Zone 2, IIC T4 (HART) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ATEX intrinsic safe Zone 2, IIC T6 (PROFIBUS or FOUNDATION Fieldbus)
Zone 2, IIC T6 (HART) VERSION N, T, D . . . . . . . . . . . . . . (c). . . .
ATEX explosionproof Zone 0, IIC T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . (d) . . .
ATEX explosionproof Zone 1, IIC T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM Nonincendive (HART)
(PROFIBUS or FOUNDATION Fieldbus) . . . . . . . . . . . . . . . (c) . . .
FM Explosionproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CSA Explosionproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM Intrinsically Safe (HART)
(PROFIBUS or FOUNDATION Fieldbus) . . . . . . . . . . . . . . (c) . . .
CSA Intrinsically Safe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (c) . . .
(continued on next page)
. . H
. . P
. . B
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0C4
0C6
1C4
1C6
2C4
. . . . . 2C6
. . . . . D0C
. . . . . D1C
. . . . . NFM
. . . . . FDZ
. . . . . CDZ
. . . . . FAA
. . . . . CAA
9
10
244LD
PSS EML0710 A-(en)
MODEL CODES 244LD (continued)
(Electrical Classification)
GOST-R Intrinsically Safe, T4 (HART) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GA4
GOST-R Intrinsically Safe, T6 (HART, PROFIBUS or FOUNDATION Fieldbus) . . . . . . . . . . . . . . . . . . . . GA6
GOST-R Explosionproof, T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GDZ
NEPSI Intrinsically Safe, T4 (HART) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NA4
NEPSI Intrinsically Safe, T6 (HART, PROFIBUS or FOUNDATION Fieldbus) . . . . . . . . . . . . . . . . . . . . . NA6
NEPSI Explosionproof, Ex d IIC T4-T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NDZ
For General Purpose Areas; not Explosionproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZZZ
OPTIONS:
Housing Complete Stainless Steel without external Pushbuttons (not available with Wafer Body Material codes K) . . . -H
Remote Amplifier Mounting Kit ( 3 m), Mounted . . . . . . . . . . . . . . . . . . . . . (e)(u) . . . . . . . . . . . . -R
Remote Amplifier Mounting Kit (10m), Mounted . . . . . . . . . . . . . . . . . . . . . (e)(u) . . . . . . . . . . . . -B
Tag No. Labeling
Stainless Steel Label Fixed With Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -L
Stainless Steel Label Fixed On Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -F
National Certificates
TA-Luft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (u). . . . . . . . . . . . . -K
ABSA (Canada). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (u). . . . . . . . . . . . . -A
Germanischer Lloyd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (q)(u) . . . . . . . . . . . . -G
Certificates
EN 10204-2.1 , Certificate Of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -1
EN 10204-2.2 , Specific Test Report (Calibration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -2
EN 10204-3.1 , Inspection Certificate Of Process Wetted Material . . . . . . . . . . . . . . . . . . . . . . . . . . -3
PED 97/23/EC additional unit verification, acc. to module F/G (Not available with Wafer Body Material codes N and I) . -4
Comply With NACE Standard MR-0175 (available with Torque Tube Material I, M or C) . (g) . . . . . . . . . . . . . -6
SIL 2 Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (q)(u) . . . . . . . . . . . . -Q
Material Test
X-Ray And Isotope Test For Weldings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -7
Dye Penetration Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -8
PMI - Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -5
Subassemblies
Torque Tube
for selected code (244LD-*********-W) . (p) . . . . . . . . . . . . . . . . . . . . . . . . . . . -W
Amplifier
for selected code (244LD-*********-X) . . (p) . . . . . . . . . . . . . . . . . . . . . . . . . . . -X
Complete Sensor for selected code (244LD-*********-Y) . . (p) . . . . . . . . . . . . . . . . . . . . . . . . . . . -Y
Wafer body
for selected code (244LD-*********-Z) . . (p) . . . . . . . . . . . . . . . . . . . . . . . . . . . -Z
Footnotes
(a) Available with Wafer Body Flange Size 1 or 2
(b) Available with Wafer Body Flange Size 3 or 4
(c) Pending
(d) Not available with Wafer Body Pressure Rating & Contact Face codes L1, J1, J2, J3, H1, H2, DD
(e) Not available with Electrical Classification FDZ, CDZ, 0C6, D0C, D1C, GDZ, NDZ or Optional Features -H
(f) only with Communication H (HART) and electrical Classification 0C6, 1C6, D0C, D1C, 2C6
(g) Restrictions concerning the limit of application for the used materials are to considering
(NACE Standard MR-0175/2003, bzw. ISO 15156-3)
(h) Pending, order separately at this time.
(i) Available with Wafer Body Flange Size 0
(k) Available with Wafer Body Flange Size 1
(m) Not available with Wafer Body Flange Size code 4 with Wafer Body Pressure Rating code J3
(n) Not availabel with Wafer Body Material codes A, K,N, I, C or Torque Tube Material codes I and M
(o) Not available with Wafer Body Material codes A, K, U, N, I, C
(p) on request
(q) Available with HART
(r) D at top
(s) F at top
(u) Not applicable with Version N, T, D
(v) Pending Electrical Classsification FDZ, CDZ, GA4, GA8, GDZ
PSS EML0710 A-(en)
11
244LD
Displacer 204DE
Typical Dimensions and Weights for Density Ranges Δ ρ 1)
316L (1.4404 / 1.4435) 2)
Material
Code
-T 3) (PN 40 / 63)
-S (PN 100)
-S (PN 250)
PTFE /
PTFE with 25 % C
Hastelloy C
-S (PN 500)
-S (PN 100 / 160)
200 ... 1500 kg/m³
300 ... 1500 kg/m³
Density Range Δ ρ
250 ... 1500 kg/m³
Len.
L
100 ... 600 kg/m³
400 ... 2000 kg/m³
ρmin4)
Vol. Wei. PN
∅ Vol. Wei. PN ∅ Vol. Wei. PN ∅ Vol. Wei. PN
cm³ N bar kg/m³ mm cm³ N bar mm cm³ N bar mm cm³ N bar
∅
mm
Vol. Wei. PN
cm³ N bar
60,3
48,3
42,4
33,7
33,7
26,9
26,9
26,9
21,3
21,3
1000
920
1060
890
1070
850
1020
1140
890
1070
19
17
21
17
20
16
19
21
20
24
100
100
100
100
100
100
100
100
100
100
101,6
88,9
76,1
60,3
60,3
51
42,4
42,4
38
38
2840
3100
3410
2855
3425
3065
2540
2825
2840
3400
38
43
44
41
48
39
38
41
37
45
40
63
63
63
63
63
63
63
63
63
460
580
545
545
675
460
495
565
425
575
42,4
42,4
33,7
26,9
26,9
21,3
21,3
21,3
17,2
17,2
500
710
670
570
680
540
640
710
580
700
18
24
21
18
22
17
20
22
16
23
250 62 1056
250 51 1021
250 42 1039
250 35 961
250 35 1153
250 30 1060
250 28 1107
250 25 981
250 22,5 993
250 20 942
23
23
24
21
25
24
25
22
23
22
500
500
500
500
500
500
500
500
500
500
60,3
48,3
48,3
33,7
33,7
26,9
26,9
26,9
21,3
21,3
1000
920
1370
890
1070
850
1020
1140
890
1070
18
19
27
19
22
18
21
23
23
27
100
100
100
100
100
160
160
160
160
160
60,3
42,4
33,7
26,9
26,9
26,9
21,3
21,3
1020
1150
1090
870
1040
1210
870
1090
20
23
20
16
19
22
20
25
100
100
100
100
100
100
100
100
101,6
76,1
60,3
51
42,4
42,4
38
38
2885
3700
3480
3115
2580
3000
2765
3455
38
47
49
40
38
44
37
46
40
63
63
63
63
63
63
63
455
595
680
465
505
635
420
595
42,4
33,7
26,9
21,3
21,3
21,3
17,2
17,2
510
730
690
540
650
760
570
710
18
23
22
18
21
23
16
24
250 62 1074
250 42 1126
250 35 1171
250 30 1076
250 28 1124
250 25 1046
250 22,5 968
250 20 957
23
26
26
24
26
24
22
22
500
500
500
500
500
500
500
500
60,3
33,7
33,7
26,9
26,9
26,9
21,3
21,3
1020
720
1090
870
1040
1210
870
1090
18
16
23
18
21
25
23
25
100
100
100
100
160
160
160
160
∅
mm
mm
350
500
750
1000
1200
1500
1800
2000
2500
3000
inch
14
32
48
60
72
84
96
120
1) Δρ = ρ1 - ρ2
ρ1 = density of lower medium
ρ2 = density of upper medium
2) Using displacer material 1.4571 can cause small deviations in diameter, volume and weight.
Accessories
For Displacer Chamber 204DC, Flange combination
204FK and Cover Flange Kit 204BCF see PSS
EML0901, 204.. Accessories for Buoyancy Transmitter.
2 0 4 B C F
3) For measurement of interface or density, the max. density of the lower medium is 1350 kg/m³.
2 0 4 B C F
2 0 4 F K
4) Min. density of the lower medium
If a Displacer Chamber is used, the difference between the diameter of the Displacer and the inside
diameter of the Displacer Chamber must be at least
10 mm.
2 0 4 F K
2 4 4 L D
Lengths < 350 mm and > 3000 mm, and density ranges < 100 kg/m³ and > 2000 kg/m³ on request.
2 0 4 D C
2 0 4 D E
2 0 4 B C F
12
244LD
PSS EML0710 A-(en)
MODEL CODES 204DE
Displacer for Buoyancy Transmitters from 2N buoyancy up to 20N 204DE
RANGE OF APPLICATION: (a)
Liquid Level
- Media: Liquid / Gas or Air
(Density difference = 250 kg/m³ to 2000 kg/m³)
(
= 9x10-3 lbm/in3 to 72.2x10-3 lbm/in3). . . . . . . . . -S
Interface Level / Density - Media: Liquid 1 / Liquid 2
(Density difference = 100 kg/m³ to 600 kg/m³)
(
= 3,6x10-3 lbm/in3 to 22.7x10-3 lbm/in3) . . . . . . . . -T
DISPLACER MATERIAL:
316L (1.4404 / 1.4435 / 1.4571) . . . . . . . . . . . . . . . . . . . . . . . . . . . S
PTFE (not for applications in Zone 0) . . . . . . . . . . . . . . . . . . . . . . . . P
PTFE With 25% Carbon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O
Hastelloy C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C
Inconel 625 (2.4856) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Monel 400 (2.4360) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M
Titan
(3.7035). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T
PRESSURE RATING:
Up to PN 100 / Class 600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
Up to PN 160 / Class 900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
Up to PN 250 / Class 1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F
Up to PN 500 / Class 2500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G
SUITABLE FOR FLANGE SIZE: (at Top of vessel/chamber)
DN 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
DN 70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DN 80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DN 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DN 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 inch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DISPLACER LENGTH "L": (inches are approx.)
for Displacer Material codes P and O:
300 mm (12 in) to 2000 mm (79 in) without partitioning . . . . . . . . . . . . . . . . . . . . . . . . . . A
2001 mm (79 in) to 4000 mm (157 in) One partition point
. . . . . . . . . . . . . . . . . . . . . . . B
4001 mm (157 in) to 6000 mm (236 in) Two partition points . . . . . . . . . . . . . . . . . . . . . . . C
6001 mm (236 in) to 8000 mm (315 in) Three partition points . . . . . . . . . . . . . . . . . . . . . . D
8001 mm (315 in) to 10000 mm (394 in) Four partition points . . . . . . . . . . . . . . . . . . . . . . E
10001 mm (394 in) to 12000 mm (472 in) Five partition points . . . . . . . . . . . . . . . . . . . . . . F
for Displacer Material S, C, I, M and T:
300 mm (12 in) to 3000 mm (118 in) without partitioning . . . . . . . . . . . . . . . . . . . . . . . . . K
3001 mm (118 in) to 6000 mm (236 in) One partition point . . . . . . . . . . . . . . . . . . . . . . . . L
6001 mm (236 in) to 9000 mm (354 in) Two partition points. . . . . . . . . . . . . . . . . . . . . . . . M
9001 mm (354 in) to 12000 mm (472 in) Three partition points . . . . . . . . . . . . . . . . . . . . . . N
12001 mm (472 in) to 15000 mm (591 in) Four partition points . . . . . . . . . . . . . . . . . . . . . . O
MATERIAL AND LENGTH OF THE SUSPENSION: (Length "b") (d)
316L / 1.4404 / … Standard length of Suspension . . . (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . S1
316L / 1.4404 / ... Customized Suspension-Length. . . (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . S2
Hastelloy C Standard length of Suspension . . . . . (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . C1
Hastelloy C Customized Suspension-Length . . . . . (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
Inconel
Standard length of Suspension . . . . . (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . I1
Inconel
Customized Suspension-Length . . . . . (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . I2
Monel
Standard length of Suspension . . . . . . (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . M1
Monel
Customized Suspension-Length . . . . . (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . M2
Titan
Standard length of Suspension . . . . . (b) . . . . . . . . . . . . . . . . . . . . . . . . . . . T1
Titan
Customized Suspension-Length . . . . . (c) . . . . . . . . . . . . . . . . . . . . . . . . . . . T2
(continued on next page)
010210
PSS EML0710 A-(en)
13
244LD
MODEL CODES 204DE (continued)
OPTIONS:
for application in Zone 0 (Additional grounding rope) (not available with Displacer Material: P) . . . . . . . . . .
Damping Spring (Mat. 1.4310, Max. 250°C (482F)) . . . . . . (f) . . . . . . . . . . . . . . . . . . . . . . . .
Damping Spring (Mat. HC, Max 350°C (662F)) . . . . . . . . (f) . . . . . . . . . . . . . . . . . . . . . . . .
Degreased . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tag No. Labeling Stainless Steel Label Fixed With Wire (Text required). . . . . . . . . . . . . . . . . . . . . .
Certificates
EN 10204-2.1 Certificate Of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN 10204-3.1 Inspection Certificate Of Process Wetted Material (not available with Displacer Material: P and O) .
PMI - Test (not available with Displacer Material: P and O) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
Product Specifications for Intelligent Transmitters
Product Specification: Device:
EMP0610
EMP0620
EMP0630
EML2610
141GP
142AP
143DP
144FP
Intelligent Gauge Pressure Transmitter
Intelligent Absolute Pressure Transmitter
Intelligent d/p Transmitter
Intelligent d/p Transmitter for Liquid Level, Interface and Density
- Flange mounted
PSS EML0610
144LD
PSS EML0710 A
PSS EML0710 G
PSS EML1610
244LD
PSS EML1710
244LVP
Intelligent Buoyancy Transmitter for Liquid Level, Interface and Density
with Displacer and Torque Tube
Intelligent Buoyancy Transmitter for Liquid Level, Interface and Density
with Displacer and Torque Tube (A: TransStar G: LevelStar)
Intelligent Buoyancy Transmitter for Liquid Level, Interface and Density
with Displacer
Intelligent Buoyancy Transmitter for Liquid Level, Interface and Density
with Displacer
PSS EML0901
204xx
PSS EMO0100
144LVD
Accessories for Buoyancy Transmitters
Accessories for Devices with HART-Protocol
.
.
.
.
.
-E
-D
-C
-O
-L
. . . -1
. . . -3
. . . -5
Footnotes
(a) Upper and Lower Medium Density required (at operating temperature)
(b) Only in connection with Modelcode 204DC
(c) Exact length required (Contact face of flange to upper end of displacer)
(d) All +/- 8mm (0.3 inch)
(e) Pending
(f) Required for 244LD Version B with Option -G
PSS
PSS
PSS
PSS
.
.
.
.
.
14
244LD
PSS EML0710 A-(en)
Dimensions
244LD up to PN 250 / Class 1500
m
6 0
2 .3 6
m
4 2 4
1 6 .7
1 2 8
8
7 0
2 2
2 0
b
6 0
2 .3 6
6 5
2 .5 6
c
in
L H
R H
1 2 0
2
3
L
1 5 0
1 4 2
3 5
> 1 0
> .3 6
5 4
2 .1 2
120
128
131
142
150
193
132
Name plate
Data label (amplifier)
Data label (transmitter)
Amplifier housing
Connection compartment
Alternative connection
Disconnection between
amplifier and measuring module
Measuring module housing
Heat sink
Wafer body
Protective tube for displacer
Displacer
Screw
Lifting hook
L H
1 9 3
c
2
3
8
20
22
35
70
R H
1 3 1
1 3 2
d
g
LH Left Hand = mounting amplifier to wafer body “Left hand mounted” (Model Code L)
RH Right Hand = mounting amplifier to wafer body “Right hand mounted” (Model Code R)
Subject to alterations - reprinting, copying and translation prohibited. Products and publications are normally quoted here without reference to existing patents, registered utility models or trademarks. The lack of any such reference does not justify the assumption that a product or symbol is free.
FOXBORO ECKARDT GmbH
Postfach 50 03 47
D-70333 Stuttgart
Tel. +49 (0)711 502-0
Fax +49 (0)711 502-597
Mail to: salessupport@foxboro-eckardt.de
http://www.foxboro-eckardt.eu
DOKT 556 588 038
Download PDF