Vaillant | climaVAIR VAM 2-085 W4N | climaVAIR - Abacus Flame

WALL MOUNTED UNITS
DMJNB7"*3
Technical Dossier
WALL MOUNTED UNITS
2010
ENG
VAM 2-050 W2N
VAM 2-060 W2N
VAM 2-085 W3N
VAM 2-110 W4N
1- CONTENTS
1- CONTENTS........................................................................................................................................................... 2
2- TECHNICAL SPECIFICATIONS................................................................................................................................ 3
3- TEMPERATURE BY CAPACITIES............................................................................................................................. 6
4- WIRING DIAGRAMS............................................................................................................................................ 10
5- ERROR CODES................................................................................................................................................... 12
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS.................................................................................................... 13
6.1- Indoor unit............................................................................................................................................................................13
6.2- Outdoor unit.........................................................................................................................................................................16
7- PCB EXPLANATION............................................................................................................................................. 20
7.1- Electric control working environment....................................................................................................................................20
7.2- Display function....................................................................................................................................................................20
7.3- Outdoor unit’s digital display tube........................................................................................................................................20
7.4- Outdoor unit point check function.........................................................................................................................................21
7.5- Protection.............................................................................................................................................................................23
7.6- Fan-only mode......................................................................................................................................................................24
7.7- Cooling mode........................................................................................................................................................................24
7.8- Dehumidifying mode.............................................................................................................................................................24
7.9- Heating mode.......................................................................................................................................................................24
7.10-Defrost.................................................................................................................................................................................25
7.11-Automatic operation mode....................................................................................................................................................25
7.12-Manual switch......................................................................................................................................................................25
7.13-Timer function......................................................................................................................................................................26
7.14-Sleep mode..........................................................................................................................................................................26
7.15-Mode conflict........................................................................................................................................................................26
7.16-Characteristic of temperature sensor.....................................................................................................................................27
ANNEX................................................................................................................................................................... 28
ENG
2- TECHNICAL SPECIFICATIONS
Model
VAM 2-060 W2N
VAM 2-085 W3N
VAM 2-110 W4N
VAI 2-025 WNI
VAI 2-025 WNI
VAI 2-025 WNI
VAI 2-025 WNI
Indoor unit 2
VAI 2-025 WNI
VAI 2-035 WNI
VAI 2-025 WNI
VAI 2-025 WNI
Indoor unit 3
\
\
VAI 2-035 WNI
VAI 2-025 WNI
Indoor unit 4
\
\
\
VAI 2-035 WNI
Outdoor unit
VAF 2-060 W2NO
VAF 2-060 W2NO
VAF 2-085 W3NO
VAF 2-085 W4NO
V/Ph/Hz
Cooling capacity
kW
5,20
5,40
8,10
9,10
BTU
17.747
18.429
27.644
31.056
Fg/h
4.472
4.644
6.966
7.826
Indoor 1
kW
2,60
2,42
2,43
2,15
Indoor 2
kW
2,60
2,98
2,43
2,15
Indoor 3
kW
/
/
3,24
2,15
/
/
/
2,65
kW
1,62
1,66
2,48
2,78
Indoor 1
kW
0,81
0,74
0,77
0,66
Indoor 2
kW
0,81
0,92
0,77
0,66
Indoor 3
kW
/
/
0,94
0,66
Indoor 4
kW
/
/
/
0,80
Min - Max cooling capacity
kW
2.18 - 6.34
2.27 - 6.53
3.40 - 9.80
3.73 - 11.09
Min - Max cooling power input
kW
0.65 - 1.99
0.66 - 2.04
0.99 - 3.06
1.11 - 3.75
Nominal capacity (UK condit)
kW
5,15
5,35
8,02
9,00
Power input (UK conditions)
kW
1,30
1,33
1,98
2,22
A
7,00
7,20
10,80
12,10
3,21
3,25
3,27
3,27
A
A
A
A
810
830
1.240
1.390
Capacity by Indoor
Indoor 4
Power input
Power input by Indoor
Operating current
EER
Energy level class
Annual consumption
kWh
kW
6,10
6,25
9,05
10,10
Heating capacity
BTU
20.818
21.330
30.886
34.469
Capacity by Indoor
Kcal/h
5.246
5.375
7.783
8.686
Indoor 1
kW
3,05
2,82
2,71
2,38
Indoor 2
kW
3,05
3,43
2,71
2,38
Indoor 3
kW
/
/
3,63
2,38
/
/
/
2,96
Indoor 4
Power input
kW
1,67
1,73
2,49
2,78
Indoor 1
kW
0,84
0,78
0,77
0,66
Indoor 2
kW
0,84
0,95
0,77
0,66
Indoor 3
kW
/
/
0,95
0,66
Indoor 4
kW
/
/
/
0,80
Min - Max heating capacity
kW
2.56 - 7.38
2.64 - 7.60
3.8 - 10.95
4.13 - 12.30
Min - Max heating power input
kW
0.67 - 2.06
0.69 - 2.11
1.0 - 3.07
1.11 - 3.72
Nominal capacity (UK condit)
kW
5,19
5,31
7,69
8,57
Power input (UK conditions)
kW
1,45
1,51
2,17
2,42
A
7,30
7,50
10,80
12,10
3,65
3,61
3,63
3,63
A
A
A
A
kW
2,15
2,15
3,10
4,80
A
10,5
10,5
16,0
21,0
Power input by Indoor
Operating current
COP
Energy level class
Max power input
Max operating current
ENG
Power supply
VAM 2-050 W2N
Indoor unit 1
2- TECHNICAL SPECIFICATIONS
INDOOR UNIT
Air flow volume
VAM 2-050 W2N
VAM 2-060 W2N
VAM 2-085 W3N
VAM 2-110 W4N
m3/h
250/300/500
250/300/500
250/300/500
250/300/500
m3/h
250/300/500
310/450/580
250/300/500
250/300/500
m3/h
/
/
310/450/580
250/300/500
m3/h
/
/
/
310/450/580
Infrared
Infrared
Infrared
Infrared
RG19B/E (white)
RG19B/E (white)
RG19B/E (white)
RG19B/E (white)
Remote control type
Remote control reference
Sound power level
Sound pressure level
Catalogue sound pressure
Indoor 1
dB(A)
40/45/51
40/45/51
40/45/51
40/45/51
Indoor 2
dB(A)
40/45/51
41/47/52
40/45/51
40/45/51
Indoor 3
dB(A)
/
/
41/47/52
40/45/52
Indoor 4
dB(A)
/
41/47/52
Indoor 1
dB(A)
28/33/39
28/33/39
28/33/39
28/33/39
Indoor 2
dB(A)
28/33/39
29/35/40
28/33/39
28/33/39
Indoor 3
dB(A)
/
/
29/35/40
28/33/39
Indoor 4
dB(A)
/
/
/
29/35/40
Indoor 1
dB(A)
26/32/38
26/32/38
26/32/38
26/32/38
Indoor 2
dB(A)
26/32/38
28/35/40
26/32/38
26/32/38
Indoor 3
dB(A)
/
/
28/35/40
26/32/38
Indoor 4
dB(A)
/
28/35/40
Testing conditions for sound pressure
Dimensions HxLxD
Net weight
Packaged dimensions HxLxD
Volume
Packaged weigth
microphone directivity,distance 1.0m
ENG
Indoor 1
mm
265 x 790 x 200
265 x 790 x 200
265 x 790 x 200
265 x 790 x 200
Indoor 2
mm
265 x 790 x 200
265 x 790 x 200
265 x 790 x 200
265 x 790 x 200
Indoor 3
mm
/
/
265 x 790 x 200
265 x 790 x 200
Indoor 4
mm
/
/
/
265 x 790 x 200
Indoor 1
Kg
8.5
8.5
8.5
8.5
Indoor 2
Kg
8.5
8.5
8.5
8.5
Indoor 3
Kg
/
/
8.5
8.5
Indoor 4
Kg
/
/
/
8.5
Indoor 1
mm
335 x 875 x 265
335 x 875 x 265
335 x 875 x 265
335 x 875 x 265
Indoor 2
mm
335 x 875 x 265
335 x 875 x 265
335 x 875 x 265
335 x 875 x 265
Indoor 3
mm
/
/
335 x 875 x 265
335 x 875 x 265
Indoor 4
mm
/
335 x 875 x 265
Indoor 1
m3
0,078
0,078
0,078
0,078
Indoor 2
m3
0,078
0,078
0,078
0,078
Indoor 3
m3
/
/
0,078
0,078
Indoor 4
m3
/
/
/
0,078
Indoor 1
Kg
10,5
10,5
10,5
10,5
Indoor 2
Kg
10,5
10,5
10,5
10,5
Indoor 3
Kg
/
/
10,5
10,5
Indoor 4
Kg
/
/
/
10,5
2- TECHNICAL SPECIFICATIONS
OUTDOOR UNIT
VAM 2-050 W2N
VAM 2-060 W2N
VAM 2-085 W3N
VAM 2-110 W4N
Air flow volume
m3/h
2.500
2.500
2.500
3.500
Sound power level
dB(A)
62
62
64
65
Sound pressure
dB(A)
52
52
55
57
1
1
1
1
Number of fans
Refrigerant
Refrigerant charge heat pump
R410A
gr
Inverter DC / AC
Number of compressors
1450
1450
2000
2400
Inverter DC
Inverter DC
Inverter DC
Inverter DC
1
1
1
1
Rotary
Rotary
Rotary
Rotary
Compressor Model
DA130S1C-20FZ
DA130S1C-20FZ
DA150S1C-20FZ
TNB220FLHMC-L
Compressor Brand
Toshiba
Toshiba
Toshiba
Mitsubishi
Compressor type
Expansion system
EXV + Capillary
Electric_electronic protections
Voltage,current, communication protection
Dimensions HxLxD
mm
695 x 845 x 315
695 x 845 x 315
695 x 845 x 315
862 x 895 x 305
Dimensions Valves A/B/C/F
mm
60/60/160/220
60/60/160/220
60/60/160/220
60/60/160/220
Dimensions Installation I/J
mm
335/560
335/560
335/560
330/590
Net weight
Kg
60,0
60,0
62,0
78,0
Packaged dimensions HxLxD
mm
770 x 970 x 400
770 x 970 x 400
770 x 970 x 400
915 x 1043 x 395
Volume
0,299
0,299
0,299
0,377
Kg
64,0
64,0
66,0
82,0
inches
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
inches
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
inches
\
\
1/4” - 3/8”
1/4” - 3/8”
inches
\
\
\
1/4” - 3/8”
inches
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
inches
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
inches
\
\
1/4” - 3/8”
1/4” - 3/8”
inches
\
\
\
1/4” - 3/8”
PM (Max pressure)
bar
42
42
42
42
pm (min pressure)
bar
25
25
25
25
Max. L1+L2+(L3)
m
30
30
45
60
Max. L1
m
15
15
15
15
Max. Height IU under OU
m
10
10
10
10
Max. Height OU under IU
m
10
10
10
10
Chargeless length
m
7,5
7,5
7,5
7,5
Additional charge per meter
gr
15
15
15
15
Packaged weight heat pump
Pipe connection liq/gas Outdoor
Pipe connection liq/gas Indoor
ENG
INSTALLATION
3- TEMPERATURE BY CAPACITIES
3.1 VAM 2-050 W2N
Cooling
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC D
15ºC W
24ºC D
17ºC W
27ºC D
19ºC W
32ºC D
23ºC W
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
Total capacity kW
5,27
5,10
4,89
4,64
4,41
4,17
3,82
Sensitive capacity kW
4,22
4,08
3,91
3,71
3,53
3,34
3,05
Input kW.
1,32
1,34
1,36
1,37
1,40
1,42
1,65
Total capacity kW
5,61
5,42
5,20
4,94
4,69
4,44
4,06
Sensitive capacity kW
4,49
4,34
4,16
3,95
3,75
3,55
3,25
Input kW.
1,45
1,47
1,49
1,51
1,53
1,55
1,81
Total capacity kW
5,90
5,71
5,47
5,20
4,94
4,67
4,27
Sensitive capacity kW
4,72
4,57
4,38
4,16
3,95
3,74
3,42
Input kW.
1,55
1,58
1,60
1,62
1,65
1,67
1,94
Total capacity kW
6,61
6,39
6,13
5,82
5,53
5,23
4,79
Sensitive capacity kW
5,29
5,12
4,90
4,66
4,43
4,18
3,83
Input kW.
1,77
1,79
1,82
1,84
1,87
1,90
2,21
HEATING
OUTDOOR CONDITIONS
24ºC D
18ºC W
12ºC D
11ºC W
7ºC D
6ºC W”
4ºC D
3ºC W
0ºC D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W”
-15ºC D
-16ºC W”
Capacity kW
5,84
7,85
6,71
5,30
4,33
4,06
3,31
1,41
Input kW.
1,84
2,22
1,80
1,62
1,52
1,51
1,49
1,30
Capacity kW
5,57
7,49
6,41
5,06
4,14
3,88
3,16
1,35
Input kW.
1,77
2,13
1,73
1,56
1,46
1,45
1,44
1,26
Capacity kW
5,31
7,14
6,10
4,82
3,94
3,69
3,01
1,28
Input kW.
1,70
2,05
1,67
1,50
1,41
1,40
1,38
1,21
Capacity kW
5,09
6,85
5,86
4,62
3,78
3,55
2,89
1,23
Input kW.
1,47
1,97
1,69
1,52
1,42
1,41
1,40
1,22
Capacity kW
4,62
6,21
5,31
4,19
3,43
3,21
2,62
1,11
Input kW.
1,79
2,16
1,76
1,58
1,48
1,47
1,46
1,27
Indoor Conditions
15ºC
18ºC
20ºC
22ºC
27ºC
ENG
3- TEMPERATURE BY CAPACITIES
3.2 VAM 2-060 W2N
Cooling
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC D
15ºC W
24ºC D
17ºC W
27ºC D
19ºC W
32ºC D
23ºC W
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
Total capacity kW
5,47
5,29
5,07
4,82
4,58
4,33
3,96
Sensitive capacity kW
4,38
4,24
4,06
3,86
3,66
3,46
3,17
Input kW.
0,64
1,05
1,28
1,56
1,75
1,76
1,78
Total capacity kW
5,82
5,63
5,40
5,13
4,87
4,61
4,22
Sensitive capacity kW
4,66
4,51
4,32
4,10
3,90
3,69
3,37
Input kW.
0,65
1,08
1,32
1,61
1,80
1,82
1,84
Total capacity kW
6,13
5,93
5,68
5,40
5,13
4,85
4,44
Sensitive capacity kW
4,90
4,74
4,54
4,32
4,10
3,88
3,55
Input kW.
0,68
1,12
1,36
1,66
1,86
1,88
1,90
Total capacity kW
6,86
6,64
6,36
6,05
5,75
5,43
4,97
Sensitive capacity kW
5,49
5,31
5,09
4,84
4,60
4,34
3,98
Input kW.
0,75
1,23
1,50
1,83
2,05
2,07
2,09
OUTDOOR CONDITIONS
24ºC D
18ºC W
12ºC D
11ºC W
7ºC D
6ºC W”
4ºC D
3ºC W
0ºC D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W”
-15ºC D
-16ºC W”
Capacity kW
6,34
7,10
6,88
5,67
5,33
4,81
4,37
2,06
Input kW.
0,62
1,29
1,87
1,88
1,68
1,37
1,27
0,96
Capacity kW
6,05
6,78
6,56
5,41
5,09
4,59
4,17
1,97
Input kW.
0,59
1,24
1,80
1,81
1,62
1,32
1,23
0,92
Capacity kW
5,77
6,46
6,25
5,15
4,84
4,38
3,97
1,88
Input kW.
0,57
1,19
1,73
1,75
1,56
1,27
1,18
0,89
Capacity kW
5,54
6,20
6,00
4,95
4,65
4,20
3,81
1,80
Input kW.
0,58
1,21
1,75
1,77
1,57
1,28
1,19
0,90
Capacity kW
5,02
5,62
5,44
4,48
4,21
3,81
3,45
1,63
Input kW.
0,58
1,22
1,77
1,79
1,59
1,30
1,21
0,91
Indoor Conditions
15ºC
18ºC
20ºC
22ºC
27ºC
ENG
HEATING
3- TEMPERATURE BY CAPACITIES
3.3 VAM 2-085 W3N
Cooling
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC D
15ºC W
24ºC D
17ºC W
27ºC D
19ºC W
32ºC D
23ºC W
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
Total capacity kW
8,21
7,94
7,61
7,23
6,87
6,50
5,95
Sensitive capacity kW
6,57
6,35
6,09
5,79
5,50
5,20
4,76
Input kW.
0,95
1,57
1,91
2,33
2,61
2,63
2,66
Total capacity kW
8,73
8,45
8,10
7,70
7,31
6,91
6,33
Sensitive capacity kW
6,99
6,76
6,48
6,16
5,85
5,53
5,06
Input kW.
0,98
1,62
1,97
2,40
2,69
2,72
2,75
Total capacity kW
9,19
8,89
8,52
8,10
7,70
7,27
6,66
Sensitive capacity kW
7,35
7,12
6,82
6,48
6,16
5,82
5,33
Input kW.
1,01
1,67
2,03
2,48
2,78
2,80
2,83
Total capacity kW
10,30
9,96
9,54
9,07
8,62
8,15
7,46
Sensitive capacity kW
8,24
7,97
7,63
7,26
6,89
6,52
5,97
Input kW.
1,11
1,84
2,24
2,74
3,06
3,09
3,13
HEATING
OUTDOOR CONDITIONS
24ºC D
18ºC W
12ºC D
11ºC W
7ºC D
6ºC W”
4ºC D
3ºC W
0ºC D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W”
-15ºC D
-16ºC W”
Capacity kW
9,18
10,29
9,96
8,21
7,71
6,97
6,32
2,99
Input kW.
0,89
1,85
2,69
2,71
2,42
1,97
1,83
1,38
Capacity kW
8,77
9,82
9,50
7,84
7,36
6,65
6,03
2,85
Input kW.
0,85
1,78
2,59
2,61
2,33
1,90
1,77
1,33
Capacity kW
8,35
9,35
9,05
7,46
7,01
6,34
5,75
2,72
Input kW.
0,82
1,72
2,49
2,51
2,24
1,83
1,70
1,28
Capacity kW
8,01
8,98
8,69
7,16
6,73
6,08
5,52
2,61
Input kW.
0,83
1,74
2,52
2,54
2,26
1,85
1,72
1,29
Capacity kW
7,26
8,13
7,87
6,49
6,10
5,51
5,00
2,36
Input kW.
0,84
1,76
2,55
2,57
2,29
1,87
1,74
1,31
Indoor Conditions
15ºC
18ºC
20ºC
22ºC
27ºC
ENG
3- TEMPERATURE BY CAPACITIES
3.4 VAM 2-110 W4N
Cooling
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC D
15ºC W
24ºC D
17ºC W
27ºC D
19ºC W
32ºC D
23ºC W
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
50ºC
Total capacity kW
9,22
8,92
8,55
8,13
7,72
7,30
6,68
Sensitive capacity kW
7,38
7,14
6,84
6,50
6,18
5,84
5,34
Input kW.
1,06
1,76
2,14
2,61
2,93
2,95
2,98
Total capacity kW
9,81
9,49
9,09
8,65
8,21
7,76
7,11
Sensitive capacity kW
7,85
7,59
7,28
6,92
6,57
6,21
5,68
Input kW.
1,10
1,81
2,21
2,69
3,02
3,05
3,08
Total capacity kW
10,33
9,99
9,57
9,10
8,65
8,17
7,48
Sensitive capacity kW
8,26
7,99
7,66
7,28
6,92
6,54
5,98
Input kW.
1,13
1,87
2,28
2,78
3,11
3,14
3,17
Total capacity kW
11,57
11,19
10,72
10,19
9,68
9,15
8,38
Sensitive capacity kW
9,25
8,95
8,58
8,15
7,75
7,32
6,70
Input kW.
1,25
2,06
2,51
3,07
3,44
3,47
3,50
OUTDOOR CONDITIONS
24ºC D
18ºC W
12ºC D
11ºC W
7ºC D
6ºC W”
4ºC D
3ºC W
0ºC D
-1ºC W
-5ºC D
-6ºC W
-7ºC D
-8ºC W”
-15ºC D
-16ºC W”
Capacity kW
10,25
11,48
11,11
9,16
8,61
7,78
7,05
3,33
Input kW.
0,99
2,07
3,00
3,03
2,70
2,20
2,05
1,54
Capacity kW
9,78
10,96
10,61
8,75
8,22
7,42
6,73
3,18
Input kW.
0,95
1,99
2,89
2,92
2,60
2,12
1,97
1,48
Capacity kW
9,32
10,44
10,10
8,33
7,83
7,07
6,41
3,03
Input kW.
0,92
1,92
2,78
2,81
2,50
2,04
1,90
1,43
Capacity kW
8,94
10,02
9,70
8,00
7,51
6,79
6,16
2,91
Input kW.
0,93
1,94
2,81
2,84
2,53
2,06
1,92
1,44
Capacity kW
8,11
9,08
8,79
7,25
6,81
6,15
5,58
2,64
Input kW.
0,94
1,96
2,85
2,87
2,56
2,09
1,94
1,46
Indoor Conditions
15ºC
18ºC
20ºC
22ºC
27ºC
ENG
HEATING
4- WIRING DIAGRAMS
Indoor units
Outdoor unit Multi 1x2
ENG
10
4- WIRING DIAGRAMS
Outdoor unit Multi 1x3
ENG
Outdoor unit Multi 1x4
11
5- ERROR CODES
Error Codes for indoor unit
Display
LED STATUS
E0
EEPROM error
E1
Communication error between indoor and outdoor unit
E2
Zero-crossing examination error
E3
Fan speed beyond control
E5
Outdoor units temp. sensor or connector of temp. sensor is defective
E6
Indoor units temp. sensor or connector of temp. sensor is defective
P0
Inverter module protection
P1
Outdoor voltage protection
P2
Compressor temp. protection
P3
Compressor current protection
P4
Inverter compressor drive error
P5
Mode conflict
LED error code display for outdoor unit
Display
LED STATUS
E0
EEPROM error
E1
No 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E2
No 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E3
No 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E6
No 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective
E4
Outdoor temp. sensor or connector of temp. sensor is defective
E5
Compressor volt protection
E7
Communication error between outdoor IC and DSP
P0
Compressor temp. protection
P1
High pressure protection (just for 27K and 36K 1x4 units.)
P2
Low pressure protection (just for 27K and 36K 1x4 units.)
P3
Compressor current protection
ENG
P4
Inverter module protection
P6
Condenser high-temperature protection
P7
Compressor driving protection
12
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
6.1indoor unit
EO: EEPROM error
E1: Outdoor communication error
ENG
E2: Zero-crossing signal error
13
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
E3: Fan speed out of control
E5: Open or short circuit of outdoor temperature sensor
E6: Open or short circuit of room or evaporator temperature sensor
ENG
14
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
P0: Inverter module protection
ENG
P1: Over voltage or too low voltage protection
15
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
P2: Temperature protection of compressor top
P3: Compressor current protection (same as Outdoor compressor current protection)
6.2outdoor uniT
EO: EEPROM error
E1, E2, E3, E6, E4: Indoor or outdoor units pipe temp. sensor or connector of pipe temp. sensor is
ENG
16
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
E5: Voltage protection of compressor
ENG
E7: Indoor and outdoor communication error
17
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
P0: Compressor top protection against temperature (same as indoor unit P2 protection)
P3: Compressor current protection
P4: Inverter module protection (drive protection arose)
ENG
18
6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS
P4 (LED flashes nine times): Inverter module protection (module protection arose)
ENG
P6: Condenser high-temperature protection.
When outdoor pipe temp. is more than 65°C, the unit will stop, and unit runs again when outdoor
pipe temp. less than 52°C.
19
7- PCB EXPLANATION
7.1
Electric Control working environment
-Input voltage: 175~253V.
-Input power frequency:50Hz.
-Indoor fan normal working amp. is less than 1A.
-Outdoor fan. Normal working amp. is less than 1.5A.
-Four-way valve normal working amp. is less than 1A.
-Swing motor: DC12V.
7.2display FUNCTION
Timer indicator
This indicator illuminates when TIMER is set ON/
OFF.
DEF. Indicator
This indicator illuminates when the air conditioner
starts defrosting automatically or when the warm
air control feature is activated in heating mode.
Temperature indicator
Usually it displays the temperature settings. When
change the setting temperature, this indicator
begins to flash, and stops 20 seconds later. It displays the room temperature when the air conditioner is in FAN only operation, and the range of that
is 0~50. When the unit stops operation, it returns
to original factory settings. It will also display
the error codes when malfunction or protection
happen.
Run indicator
Flash at 0.5Hz when the unit is standby. Illuminate
when the unit is turned on.
Auto indicator
This indicator illuminates when the air conditioner
is in AUTO operation.
Frequency indicator
This indicator appears only when the compressor
is in operation and indicates the current operating
frequency.
Ion indicator
Illuminate when Ionizer/Plasma function is activated.
LED display control function.
Pressing “LED display” button on remote controller will turn off all displays on indoor unit, while pressing
once again, all displays will resume.
ENG
7.3
Outdoor unit’s digital display tube
There is a digital display tube in outdoor PCB.
frequency.
• In defrosting mode, The LED displays “dF”
• In compressor pre-heating, The LED displays “1
1”
• In protection or malfunction, the LEC displays
error code or protection code.
Digital display tube display function
• In standby , The LED displays the number of
indoor units.
• In compressor operation, the LED display the
20
7- PCB EXPLANATION
7.4
Outdoor unit point check function
There is a check switch in outdoor PCB.
Push the switch SW1 to check the states of unit when the unit is running. The digital display tube will display the follow
procedure when push SW1 each time:
Display
1
Remark
Indoor unit capacity demand code
2
Outdoor unit running mode code
3
Amendatory capacity demand code
Off:0, Cooling:1, Heating:2
4
Outdoor unit fan motor state
Off:0, Low speed:1, High speed:2
5
Evaporator outlet temp. for 1# indoor unit
Actual data
6
Evaporator outlet temp. for 2# indoor unit
Actual data
7
Evaporator outlet temp. for 3# indoor unit
Actual data
8
Evaporator outlet temp. for 4# indoor unit
Actual data
9
Condenser pipe temp.
Actual data
10
Ambient temp.
Actual data
11
Compressor discharge temp.
Actual data
12
Inverter current
Actual data
13
EXV open angle for 1# indoor unit
Actual data×8
14
EXV open angle for 2# indoor unit
Actual data×8
15
EXV open angle for 3# indoor unit
Actual data×8
16
EXV open angle for 4# indoor unit
Actual data×8
17
Indoor unit number
The indoor unit can communicate with outdoor unit well.
18
The last error or protection code
00 means no malfunction
19
――
Check point over
Frequency of compressor:
Display
Frequency of compressor (Hz)
30
30
--
Stand by
60
60
Display
Corresponding mode
0
Off
1
Cooling mode
2
Heating mode
Capacity demand:
Cooling mode
Capacity
20002500
20002500
30003800
45005000
50005500
55006100
61007000
70007500
75008000
75008000
Corresponding Code
1
2
3
4
5
6
7
8
9
>=10
Heating mode
Capacity
20002500
20002500
30003800
45005000
55006100
61007000
61007000
70007500
75008000
80008900
Corresponding Code
1
2
3
4
5
6
7
8
9-10
>=11
Note: The capacity is just for reference.
21
ENG
Running mode:
7- PCB EXPLANATION
Number of indoor unit
Display
Number of indoor unit
1
1
2
2
3
3
Outdoor ambient temp:
Display
Corresponding temp.
Display
Corresponding temp.
Display
15
-7.5
50
10
80
Corresponding temp.
25
16
-7
51
10.5
81
25.5
17
-6.5
52
11
82
26
18
-6
53
11.5
83
26.5
19
-5.5
53
11.5
84
27
20
-5
54
12
85
27.5
21
-4.5
55
12.5
86
28
22
-4
56
13
87
28.5
23
-3.5
57
13.5
88
29
24
-3
58
14
89
29.5
26
-2
59
14.5
90
30
27
-1.5
60
15
91
30.5
28
-1
61
15.5
92
31
29
-0.5
62
16
93
31.5
30
0
63
16.5
93
31.5
31
0.5
63
16.5
94
32
32
1
64
17
95
32.5
33
1.5
65
17.5
96
33
34
2
65
17.5
97
33.5
35
2.5
66
18
98
34
36
3
67
18.5
99
34.5
37
3.5
68
19
10.
35~40
38
4
69
19.5
11.
40~45
45~50
39
4.5
70
20
12.
40
5
71
20.5
13.
50~55
41
5.5
72
21
14.
55~60
42
6
73
21.5
15.
60~65
43
6.5
74
22
16.
65~70
44
7
75
22.5
22.5
ENG
45
7.5
75
46
8
76
23
47
8.5
77
23.5
48
9
78
24
49
9.5
79
24.5
Current of outdoor unit
Display
Corresponding mode
44
6.0 A
46
6.2 A
54
7.4 A
55
7.6 A
22
7- PCB EXPLANATION
58
7.6 A
62
8.0 A
66
8.6 A
67
8.8 A
68
9.0 A
70
9.2 A
72
9.5 A
76
10.0 A
78
10.2 A
80
10.4 A
82
10.6 A
84
11.0 A
88
11.6 A
92
12.0 A
94
12.2 A
-No. 1 opening degree of electronic expansion valve:
Opening degree equals the display data times 8
-No. 2 opening degree of electronic expansion valve:
Opening degree equals the display data times 8
-No. 3 opening degree of electronic expansion valve:
Opening degree equals the display data times 8
7.5
Protection
-3 minutes delay at restart for compressor.
-Discharge temperature protection of compressor, compressor stops when the temp. of discharge is more than 115℃ and
last out 10 s. compressor runs when the temp. of discharge is less than 90℃.
-Temperature protection of compressor top, compressor stops when the temp. of top of compressor is more than 120℃,
compressor runs when the temp. of top of compressor is less than 105℃.
-When AC voltage  265V for 30 seconds, Outdoor Unit stops operation and alarms. When AC voltage  265V for 30
seconds, Outdoor Unit resumes operation.
-Inverter module Protection , Inverter module Protection itself has a protection function against current, voltage and
temperature.
-Sensor protection at open circuit and breaking disconnection
-Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High Fan+300RPM)or too low(lower than
400RPM), the unit stops and LED displays failure information and can’t return to normal operation automatically.
-Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops and LED displays failure
-Current protection: When the current is more than ‘X’ A, the compressor stops.
(X is 7A for 14K 1x2 unit, is 14A for 18K 1x2 unit, is 13.5A for 21 1x3 unit, is 15A for 27K 1x3 unit, is 16A for 27K 1x4 unit and
is 21.5A for 36K 1x4 unit. )
-Outdoor condenser high temperature protection: Under cooling mode, if T3>65℃ for 3 minutes, the compressor will
stop. When T3<52℃, the protection is not valid.
-Pressure protection (just be available for 27K and 36K 1x4 unit): If low pressure is lower 0.03MPa, the compressor will
stop and when low pressure is higher than 0.10MPa, the compressor will restart. If high pressure is higher than 3.3MPa,
23
ENG
information and can’t return to normal operation automatically.
7- PCB EXPLANATION
the compressor will stop and when high pressure is lower than 2.4MPa, the compressor will restart.
-Compressor pre-heating function: When the outdoor temperature is lower than 3℃ and the compressor stops operation
for more than 3 hours, or the outdoor temperature is lower than 3℃ and the power is just put on, the compressor enters
into pre-heating condition. When outdoor temp. is more than 5℃ or user operate it, pre-heating condition will finish.
7.6 Fan-only mode
Fan speed is high/mid/low/ Auto
7.7
Cooling mode
-Indoor fan keeps running, fan speed can be set in high/mid/low/ Auto:
-Auto fan at cooling mode: (T=Indoor Temp.-Setting Temp.)
Condition
Indoor fan speed
Room temp. up
Room temp. down
T<1.5℃
Low
1.5℃<T<4℃
Mid.
T>4℃
High
T> 3℃
High
1℃<T<3℃
Mid.
T<1℃
Low
-Anti-freezing control to indoor evaporator at cooling mode (T: evaporator temp.)
Evaporator Temp.
Compressor
T< 4℃
Off
T > 8℃
On
7.8 Dehumidifying mode
-The indoor fan is fixed in low speed
-Low room temperature protection:
When room temperature decreases to below 10ºC, indoor fan stop, when room temperature restores to over 12ºC,
indoor fan start.
-At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that of cooling mode.
7.9
Heating mode
-Indoor Fan actions at heating mode
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but
Anti-cold wind function prevails.
Anti-cold wind control function at heating mode
ENG
Condition
T= Indoor exchanger temp.
Indoor exchanger temp. up
Indoor exchanger temp. down
Indoor fan speed
T<34℃
Off
34℃<T<37℃
Breeze
37℃<T<44℃
Low speed
T> 44℃
Setting fan speed
T> 38℃
Setting fan speed
33℃<T<38℃
Low speed
24℃<T<33℃
Breeze
T<24℃
Off
24
7- PCB EXPLANATION
Auto wind at heating mode
Condition
T=Indoor Temp.-Setting Temp.
Indoor fan speed
T<1.5℃
High
1.5℃<T<2.5℃
Mid.
Room temp. up
T>2.5℃
Low
T<1.0℃
High
1.0℃<T<2.0℃
Mid.
T>2.0℃
Low
Room temp. down
Indoor evaporator high-temperature protection at heating mode
Condition
T= Indoor exchanger temp.
Compressor
T<48℃
On
53℃<T<63℃
Decrease frequency of compressor
T>63℃
Off
Defrosting operation (Available for heating only).
7.10 Defrost
-Defrosting condition: The temperature of outdoor heat exchanger remains consecutively lower than -2°c for more than
40 minutes,
-Ending condition of defrosting: If one of following conditions is satisfied, end the defrost and turn into heating mode:
a. The defrost time has reached to 10 minutes.
b. When the temperature of outdoor heat exchanger rises up to 15°C
-Defrosting Actions:
a. Compressor runs
b. 4 way valve switches off
c. Outdoor fan switches off
d. Indoor fan running according to anti-cold wind function in heating mode
7.11 Automatic operation mode
The air conditioner automatically selects one of the following operation modes: cooling, heating or fan only according
to the temp. difference between room temp. (TA) and set temp. (TS).
TA—TS
Operation mode
TA—TS>2ºc
Cooling
-1ºc≤TA-TS≤+2ºc
Fan-only
TA-TS<-1ºc
Heating (air-only for cooling only type)
-At auto mode, the A/C operates with a set temp. of 24℃
25
ENG
7.12 Manual switch
-Mode changes when push this button .
Cooing mode Auto modeUnit off Cooing mode
-At Cooing mode, after 30 minutes cooling operation whose fan speed is set as low, the
A/C operates with a setting temp. of 24℃.
7- PCB EXPLANATION
7.13timer function
-The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes.
-Timer on: first turn off the A/C, the A/C will be automatically on at the set time.
-Timer off: first turn on the A/C, the A/C will be automatically off at the set time
-Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be automatically on at set time, and
later be off at the set time, then unit turns on at set time.
-Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be automatically off at set time, and
later be on at the set time, then unit turns off at set time.
7.14sleep mode
-It is available at cooling, heating or auto mode.
-Cooling: The set temperature rise 1ºC per hour. Two hours later, the set temperature will maintain as a constant and
the fan speed is kept at low speed.
-Heating: The set temperature decrease 1ºC per hour. Two hours later, the set temperature will maintain as a constant and
the air circulation is kept at low speed (Cold air proof function takes precedence over all).
-Auto: The Sleep Mode running function operates in accordance with selected running mode by auto
mode.
-After 7 hours, unit cancels this mode automatically.
J2
On
On
Off
J3
On
Off
On
Off
Off
Stop time
7 hours
8 hours
6 hours
7 hours
-Auto restart function: In case of a sudden power failure, this function automatically sets the unit to previous settings
before the power failure when power returns.
7.15mode conflict
The indoor units can not work cooling mode and heating at same time. Heating mode has a priority.
Definition
Cooling mode
Heating Mode
Fan
Off
Cooling mode
No
Yes
No
No
Heating Mode
Yes
No
Yes
No
Fan
No
Yes
No
No
Off
No
No
No
No
No: No mode conflict
Yes: Mode conflict
ENG
-Unit action
• In case of one Indoor unit working in cooling mode or fan mode, and another indoor unit is set to heating mode, the
indoor unit working in cooling mode or fan mode will change to stand by. The outdoor unit will work in heating mode.
• In case of one Indoor unit working in heating mode, and another indoor unit is set to cooling mode or fan mode, the
indoor unit setting to cooling mode or fan mode will change to stand by.
26
7- PCB EXPLANATION
Temp.℃
Resistance KΩ
Temp.
Resistance KΩ
Temp.
Resistance KΩ
-10
62.2756
17
14.6181
44
4.3874
-9
58.7079
18
13.918
45
4.2126
-8
56.3694
19
13.2631
46
4.0459
-7
52.2438
20
12.6431
47
3.8867
-6
49.3161
21
12.0561
48
3.7348
-5
46.5725
22
11.5
49
3.5896
-4
44
23
10.9731
50
3.451
-3
41.5878
24
10.4736
51
3.3185
-2
39.8239
25
10
52
3.1918
-1
37.1988
26
9.5507
53
3.0707
0
35.2024
27
9.1245
54
2.959
1
33.3269
28
8.7198
55
2.8442
2
31.5635
29
8.3357
56
2.7382
3
29.9058
30
7.9708
57
2.6368
4
28.3459
31
7.6241
58
2.5397
5
26.8778
32
7.2946
59
2.4468
6
25.4954
33
6.9814
60
2.3577
7
24.1932
34
6.6835
61
2.2725
8
22.5662
35
6.4002
62
2.1907
9
21.8094
36
6.1306
63
2.1124
10
20.7184
37
5.8736
64
2.0373
11
19.6891
38
5.6296
65
1.9653
12
18.7177
39
5.3969
66
1.8963
13
17.8005
40
5.1752
67
1.830
14
16.9341
41
4.9639
68
1.7665
15
16.1156
42
4.7625
69
1.7055
16
15.3418
43
4.5705
70
1.6469
27
ENG
characteristic of temperature sensor
ANNEX
ENG
28
ENG
NOTES
29
NOTES
ENG
30
ENG
NOTES
31
Saunier Duval reserves the right to modify specifications without prior notice.
VAM2-WN-TD 12/2009