datasheet for EPQ
EPQ-A24T5M
Type: Instant Start Electronic Ballast
Lamp Connection: Parallel
Lamp Applications: Three or Four F24T5 24 Watt
SLI lamps or GE, Philips or Sylvania/OSRAM cross reference lamps
SPECIFICATIONS
Input
Voltage
Number
of Lamps
Lamp
Type
Lamp
Watts
Input Watts
(typical)
Input Current
(typical)
Power
Factor
Max
THD
Crest
Factor
Ballast
Factor
120V
230V
277V
120V
230V
277V
4
4
4
3
3
3
F24T5
F24T5
F24T5
F24T5
F24T5
F24T5
24W
24W
24W
24W
24W
24W
82W
84W
84W
66W
66W
68W
0.68A
0.36A
0.30A
0.55A
0.29A
0.25A
0.99
0.99
0.99
0.99
0.98
0.98
<10%
<10%
<10%
<10%
<15%
<15%
<1.7
<1.7
<1.7
<1.7
<1.7
<1.7
0.81
0.84
0.84
0.84
0.86
0.87
SAFETY & PERFORMANCE
•120-277V,50-60HzInputVoltage
•ULListed
•cULListed
•TypeHL
•Type1Outdoor
•SurgeProtection
•SoundRatedA
•AutoRestart
•ClassPThermallyProtected(Inherent)
•RFI/EMI:MeetsFCCPart18SubpartC
•NoPCBs
LINE
BLACK
WHITE
YELLOW
YELLOW
BALLAST
BLUE
BLUE
RED
RED
Length (L)
9.50"
Width (W)
1.70"
LAMP
Height (H)
1.14"
LAMP
Mounting (M)
8.9"
Weight
1.50 lbs.
Case Qty.
20 pcs.
LAMP
LAMP
LINE
BLACK
WHITE
YELLOW
YELLOW
BLUE
BLUE
RED
RED
Cap Off One
Red Wire
Black
18.8"
LAMP
White
18.8"
LAMP
Blue
30.9"
Red
30.9"
Yellow
46.4"
LAMP
•4LampApplication:MinimumStartingTemp-10°C
•3LampApplication:MinimumStartingTemp0°C
•MaximumCaseTemp90°C
•RemoteWiringLengthupto18ft
•InstallinaccordancewiththeNationalElectricalCode
•Usewith600Vratedwire
•Useexternalgroundwire
•Donotconnectanylampleadtoneutral
•Mountingsideofballastpackagemustbeincompletecontact
withmetalicixturesurfaceforproperthermaldissipation
BALLAST
Wiring Lengths
APPLICATION
INSTALLATION
Dimensions
RoHS
COMPLIANT
L E A D - F R E E
WARRANTY
ACElectronicswarrantstothepurchaserthateach
electronicballastwillbefreefromdefectsinmaterial
orworkmanshipforaperiodof5yearsfromthedate
ofmanufacturewhenproperlyinstalledandunder
normalconditionsofuse.
Administration & Distribution Center: 3401 Avenue D, Arlington, TX 76011
1-800-375-6355 • www.ace-ballast.com
Data is based upon tests performed by AC Electronics in a controlled environment and representative performance. Actual performance can vary
depending on operating conditions. Speciications are subject to change without notice. All speciications are nominal unless otherwise noted.