RB610 - Break Away Relays Specifications:

RB610 - Break Away Relays Specifications:
RB610 - Break Away Relays
Specifications:
• Each cluster contains six (6)
relay modules which can
easily be separated.
• 12VDC or 24VDC
selectable operation.
• Coil draws 50mA.
• 10 amp/120VAC/28VDC
SPDT contacts.
• Screw terminals accommodate
up to 12 gauge wire.
Board dimensions: 2"L x 1.5"W x 1"H
JMPR
C
12 VD
SET 24 VDC
FACT MPR FOR
J
CUT
R B 1 0O R Y
JMPR
JMPR
RB10
RB10
FACTORY SET 12 VDC
CUT JMPR FOR 24 VDC
FACTORY SET 12 VDC
CUT JMPR FOR 24 VDC
NC
NC
NO
C
+
---
NC
NO
C
+
JMPR
NC
NO
+
C
NO
---
JMPR
JMPR
RB10
RB10
RB10
FACTORY SET 12 VDC
CUT JMPR FOR 24 VDC
FACTORY SET 12 VDC
CUT JMPR FOR 24 VDC
FACTORY SET 12 VDC
CUT JMPR FOR 24 VDC
C
+
---
NC
NO
C
+
---
---
NC
NO
C
+
---
Installation Instructions:
1. In order to break the relay cluster apart
(if desired) put a pencil on a flat surface, position the scoring line on top of the pencil and push lightly.
Relay should easily breakaway from cluster.
2. Connect trigger input or voltage source to screw terminals marked [POS (+) & NEG (-)].
(Unit is factory set for 12VDC operation - cut jumper for 24VDC operation).
3. Connect screw terminals marked [N.C. (Normally Closed) or N.O.
(Normally Open) and C (Common)] to operate desired devices.
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056