Delta Digital timer User manual

Delta Digital timer User manual

Timers

Time Switches

Counters

Logic Controllers

Supply

Monitoring

Devices

PID Controllers

GIC

General Industrial Controls Private Limited (GIC), is offering services as a well established

manufacturer and exporter of Process Control and Automation products with unparalleled sophistication and expertise. We are an ISO 9001:2008, TS 16949 certified company with

International approvals like cUL

US

. Our products are Eco-friendly, RoHS compliant and CE certified. Brand "GIC" has been built on this strong foundation over the past three decades signifying reliability, quality and value for money.

Our product categories include 1) Lighting Automation: Time Switches and Lighting Management

Console 2) Process Control: Mini PLCs, Timers, PID Temperature Controllers 3) Low Voltage

Protection and Switchgear: Voltage Protection, Frequency, Thermistor & Earth Leakage Relays 4)

Instrumentation: Hour Meters, Impulse Counters and 5) Injection Moulded Plastic Components for various applications.

RoHS Compliant

INDEX

CONTENTS

®

PAGE NOS.

TM

2

TIMERS

Electronic Timer - Series Micon™ 175

Electronic Timer - Series Micon™ 225

Electronic Timer - Series Micon™ 350

Electronic Timer - Series Micon™ 480

Electronic Timer - Series Micon™ 780

Electronic Timer - Series Staircase™

Digital Timer

®

Synchronous Timer - Series EM 1000

Synchronous Timer - Series EM 2000

Glossary

Operating Modes / Functions

GIC

www.gicindia.com

TM

Electronic Timer - Series Micon 175

• Compact 17.5mm

• Time range: 0.3s - 30h

• Highly accurate

• Functions: On Delay, One Shot

• Integrated dual voltage selection

• Separate indications for power and relay status

• Low power consumption

Cat. No.

Parameters

Mode

Functional Diagram

11ODT4

ON Delay

11BDT4

One Shot

R

= Supply

R = Relay

R

T T

1 Sec.

Supply Voltage ( )

Supply Variation

Frequency

Timing Ranges

Reset Time

Accuracy:

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Switching Frequency

@ rated max load

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

110 VAC / 24 VAC/DC

(Selectable)

- 20% to +10% (of )

50/60 Hz

0.3s to 30h

100 ms (Max.)

± 5% of Full scale

± 1%

1 C/O (SPDT)

5A (resistive) @ 240 VAC / 28 VDC

Ag Alloy

5

1X10

1000 operations/h (Max.)

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-10 °C to +55°C

-20 °C to +70°C

Green LED Power ON, Red LED Relay ON

Flame Retardant UL94V0

18 X 65 X 90

75 g

Base / DIN rail

RoHS Compliant

IP 20 for Terminals, IP 30 for Enclosure

110 VAC / 24 VAC/DC

(Selectable)

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms

ORDERING INFORMATION

Cat. No.

Description

11ODT4

12ODT4

15ODT4

11ODT8

12ODT8

110 VAC, 24 VAC/DC, On Delay

240 VAC, 24 VAC/DC, On Delay

12 VDC, On Delay

110 VAC, 24 VAC/DC, On Delay Retentive

240 VAC, 24 VAC/DC, On Delay Retentive

11BDT4

12BDT4

15BDT4

110 VAC, 24 VAC/DC, One Shot

240 VAC, 24 VAC/DC, One Shot

12 VDC, One Shot

MOUNTING DIMENSION (mm)

17.5 (+0.5, -0.0)

CONNECTION DIAGRAM

4

A = 58.5 (Without Dust Cover)

B = 65 (With Dust Cover)

A

B

*Note: For terminal torque & terminal capacity please refer page no. 16

TM

Electronic Timer - Series Micon 175

• Compact 17.5mm

• Wide time range: 0.1s - 100h

• Highly accurate

• Multi-function: 10 different functions (Signal & Non Signal based)

• Multi-voltage: Single model suitable for both AC and DC applications

• Separate indications for power and relay status

• Low power consumption

Cat. No.

Supply Voltage ( )

Supply Variation

Frequency

Signal Supply Range

Power Consumption (Max.)

Modes

1CMDT0

12 - 240 VAC/DC

- 15% to +10% (of )

50/60 Hz

As per Supply Voltage ( )

2 VA

1. On Delay [tn], 2. Cyclic ON/OFF [cnf], 3. Cyclic OFF/ON [cfn], 4. Signal OFF Delay [sf], 5. Signal OFF/ON [sfn],

6. Accumulative Delay on Signal [san], 7. Impulse ON/OFF [inf], 8. Leading Edge Impulse [iL], 9. Trailing Edge

Impulse [it], 10. Leading Edge Bi-stable [sbi]

Timing Ranges

Accuracy:

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

LED Indication

Initiate Time

Reset Time

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Harmonic Current Emissions

ESD

Radiated Susceptibility

Electrical Fast Transients

Surges

Conducted Susceptibility

Voltage Dips & Interruptions

Conducted Emission

Radiated Emission

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Non-repetitive shock

ORDERING INFORMATION

Cat. No.

1CMDT0

1CMDTB

0.1s to 100h

± 5% of Full scale

± 1%

1 C/O (SPDT)

8A (resistive) @ 240 VAC / 5A (resistive) @ 24 VDC

Ag Alloy

1X10

5

1X10

7

Green LED Power ON, Yellow LED Relay ON

100 ms (Max.)

100 ms (Max.)

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-15°C to +60°C

-20°C to +80°C

95% (Rh)

Flame Retardant UL94-V0

18 X 60 X 85

70 g

Base / DIN rail

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

IEC 61000-3-2

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-11

CISPR 14-1

CISPR 14-1

Ed. 3.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 3.0 (2006-02) Level IV

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level III

Ed. 2,2 (2006-05) Level III

Ed. 2.0 (2004-03) Performance Criteria B/A

Ed. 5.0 (2005-11) Class A

Ed. 5.0 (2005-11) Class A

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms

Description

12 - 240 V AC/DC, Multifunction (10 Modes), 1 C/O, Dark Grey Casing

12 - 240 V AC/DC, Multifunction (10 Modes), 1 C/O, Light Grey Casing

TERMINAL TORQUE & TERMINAL CAPACITY

5

6

TM

Electronic Timer - Series Micon 175

FUNCTIONAL DIAGRAMS FOR 1CMDT0 & 1CMDTB

U

ON DELAY [tn]

R

T

Timing commences when supply is present.R energizes at the end of the timing period.

T

CYCLIC ON/OFF [cnf]

U

R

TON

TOFF

TON

TOFF

This function is quite similar to the function ‘1’ but initially the relay(R) is ON for period

T-ON after the power is applied.

CYCLIC OFF/ON [cfn]

U

R

TOFF TOFF

TON TON

T-ON and T-OFF can be same or different. The relay(R) keeps on changing its status till power is removed.

SIGNAL

OFF DELAY [sf]

U

B1

R

T T

R energizes when switch B1 is closed. Timing commences after S is opened and then the relay de-energizes.

SIGNAL OFF/ON [sfn]

U

B1

R

When switch B1 is closed or opened for preset time ,T, the relay changes its state after time duration T.

T T

ACCUMULATIVE DELAY

ON SIGNAL [san]

U

B1

R t1 t2

T+t1+t2 T

Time commences as supply is present and switch B1 is open. Closing switch B1 pauses timing. Timing resumes when switch B1 is opened again. R energizes at the end of timing.

IMPULSE ON/OFF [inf]

U

B1

R

T T T

R energizes for the timing period when B1 is opened or closed. When timing commences, changing state of B1 does not affect R but resets timer.

TRAILING EDGE

IMPULSE1 [it]

U

LEADING EDGE

IMPULSE2 [il]

B1

R

T

When switch B1 is closed, and remains closed output relay energizes until timing is over. If B1 is opened during timing, R resets.

U

B1

R

T

When B1 is opened, R energizes and de-energizes when timing is over. If B1 is closed during timing R resets.

LEADING EDGE

BISTABLE [sbi]

U

B1

R

Relay energizes when B1 is closed. Further every time B1 is closed,

R keeps on changing its status till supply is on

MOUNTING DIMENSION (mm) CONNECTION DIAGRAM

TM

Electronic Timer - Series Micon 225

• World-Class design

• Compact 22.5mm

• Single and Multi-function

(Non-Signal and Signal based) timers

• Multi-voltage: Single model suitable

for both AC and DC applications

• Flush knobs for better security

• LED indications for runtime and relay status

• Excellent Noise Immunity to the latest IEC standards

Cat. No.

Parameters

Mode

2A5DT5

Multi-function Multi range

2AJDT0

Asymmetrical ON-OFF / OFF-ON

2ASDT0

Star-Delta

Functional Diagram

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Timing Ranges

Pause Time (P)

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Switching Frequency

@ rated max load

AC - 15

Utilization Category

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

A.

ON

DELAY

25-28

15-18

Ts

B.

INTERVAL

25-28

15-18

Ts

C.

CYCLIC

ON/OFF

25-28

15-18

Ts

Ts

D.

CYCLIC

OFF/ON

25-28

15-18 Ts

Ts

E.

ONE

SHOT

25-28

15-18

Ts

1s

Ts = T x t

24 - 240 VAC/DC

- 20% to +10%

(of )

50/60 Hz

4 VA

0.1s to 10h

N. A.

Max. 200 ms

15-18

± 5% of Full scale

+ 1%

2 C/O (DPDT)

5A @ 240 VAC / 28 VDC (Resistive)

Ag Alloy

1x10

5

1x10

7

1 C/O (SPDT)

A

B

Off

On

On Off

T1 x t1 = ON Time

T2 x t2 = OFF Time

Electrical : 1800 Operations / h

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-15°C to +60°C

-20°C to +80°C

95% (Rh)

Green LED Power ON, Red LED Relay ON

Flame Retardant UL94-V0

22.5 X 75 X 100.5

130 g

Base / DIN rail

15-18

Ts

25-28

P

Ts = T x t

P = Pause Time

7 VA

0.3s to 120s

60ms, 90ms, 120ms, 150ms

Star - 1 'NO', Delta - 1 'NO'

Red 1- ON, Red 2- ON

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms

ORDERING INFORMATION

Cat. No.

Description

2A5DT5

2B5DT5

273DT5

2AODT5

29ODT5

24-240 VAC/DC, Multi-function, 2 C/O

240-415 VAC, Multi-function, 2 C/O

240 VAC, Multi-function (On Delay, Interval, Cyclic), 2 C/O

24-240 VAC/DC, On Delay, 2 C/O

9-32 VDC, On Delay, 2 C/O

2ASDT0*

2ASDT1

2BSDT0*

2BSDT1

24-240 VAC/DC, Star-Delta, 1 NO (Star) + 1 NO (Delta)

24-240 VAC/DC, Star-Delta, 1 NO (Star) + 1 NO (Delta)

240-415 VAC, Star-Delta, 1 NO (Star) + 1 NO (Delta)

240-415 VAC, Star-Delta, 1 NO (Star) + 1 NO (Delta)

2AJDT0*

2AJDT1

2AADT5

25ADT5

24-240 VAC/DC, Asymmetric ON/OFF, OFF/ON, 1 C/O

24-240 VAC/DC, Asymmetric ON/OFF, OFF/ON, 1 C/O

24-240 VAC/DC, Asymmetric ON/OFF, 2 C/O

12 VDC, Asymmetric ON/OFF, 2 C/O

*Note: Product with test voltage between input and output at 1.5 kV

7

TM

Electronic Timer - Series Micon 225

• Multi-function Timer with 1 Instant + 1 Delayed contact

8

Cat. No.

Parameters

Mode

2A6DT6 2B6DT6

ON Delay, Interval, Cyclic ON/ ,

Functional Diagram

A.

ON

DELAY

25-28

15-18

Ts

B.

INTERVAL

25-28

15-18

Ts

C.

CYCLIC

ON/OFF

25-28

15-18

Ts

Ts

D.

CYCLIC

OFF/ON

E.

ONE

SHOT

25-28

15-18

Ts

Ts

25-28

15-18

Ts

1s

F.

ON DELAY

25-28

(1 INSTANT

+

1 DELAY)

15-18

Ts

Ts = T x t

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Timing Ranges

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Switching Frequency

@ rated max load

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

24 - 240 VAC/DC

- 20% to +10%

(of )

50/60 Hz

4 VA

0.1s to 10h

Max. 200 ms

± 5% of Full scale

+ 1%

2 Delayed C/O (for 1st 5 modes), 1 Instant + 1 Delayed (for 6th mode)

5A @ 240 VAC / 28 VDC (Resistive)

Ag Alloy

1x10

5

1x10

7

Electrical : 1800 Operations / h

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-15° C to +60° C

-20° C to +80° C

95% (Rh)

Green LED Power ON

Red LED Relay ON

Flame Retardant UL94-V0

22.5 X 75 X 100.5

130 g

Base / DIN rail

240 - 415 VAC

7 VA

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) Level 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 30g, 15ms

ORDERING INFORMATION

Cat. No.

2A6DT6

2B6DT6

Description

24-240 VAC/DC, Multi-function, 2 C/O or 1 Instant + 1 Delayed C/O

240-415 VAC, Multi-function, 2 C/O or 1 Instant + 1 Delayed C/O

TM

Electronic Timer - Series Micon 225

• Signal based Multi-function

Cat. No.

Parameters

Mode

2ANDT0

Signal ON Delay, Accumulative ON Delay, Signal OFF Delay, Signal OFF/ON Delay, Leading Edge Impulse 1, ON Delay, Interval

Functional Diagram

= Supply

S = Signal

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Timing Ranges

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Switching Frequency

@ rated max load

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

24 - 240 VAC/DC

- 20% to +10%

50/60 Hz

(of )

4 VA

0.1s to 10h

Max. 200 ms

± 5% of Full scale

+ 1%

1 C/O (SPDT)

5A @ 240 VAC / 28 VDC (Resistive)

Ag Alloy

1x10

5

1x10

7

Electrical : 1800 Operations / h

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-15° C to +60° C

-20° C to +80° C

95% (Rh)

Green LED Power ON

Red LED Relay ON

Flame Retardant UL94-V0

22.5 X 75 X 100.5

130 g

Base / DIN rail

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) Level 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 30g, 15ms

ORDERING INFORMATION

Cat. No.

2ANDT0

Description

24-240 VAC/DC, Signal Based Multi-function

9

TM

Electronic Timer - Series Micon 225

• Signal based Multi-function with Solid State Output.

10

Cat. No.

Parameters

Mode

20NDTT

Signal ON Delay, Accumulative ON Delay, Signal OFF Delay, Signal OFF/ON Delay, Leading Edge Impulse 1, ON Delay, Interval

Functional Diagram

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Timing Ranges

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Solid State Output:

Type

Form

Rated Current

Max. Admissible Current

Leakage Current

Voltage Breaking Capacity

Max. Voltage Drop at Terminals

Minimum Load Current

Electrical Life

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

= Supply

S = Signal

110 - 240 VAC

- 20% to +10%

50/60 Hz

3 VA

0.06s to 10h

Max. 100 ms

(of )

± 5% of Full scale

+ 1%

Optical Isolation

SPST

1A (AC)

20 A (10ms)

<5 mA

110 - 240 VAC

<= 8 V

20 mA

6

1 x 10

-15° C to +60° C

-20° C to +80° C

95% (Rh)

Green LED Power ON

Red LED Output ON

Flame Retardant UL94-V0

22.5 X 75 X 100.5

107 g

Base / DIN rail

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) Level 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 30g, 15ms

ORDERING INFORMATION

Cat. No.

20NDTT

20JDTT

Description

110-240 VAC, Solid State Signal Based Multi-function

110-240 VAC, Solid State Asymmetrical ON-OFF / OFF-ON

TM

Electronic Timer - Series Micon 225

• True OFF delay (Power OFF Delay) upto 600 seconds with 2 C/O.

Cat. No.

Parameters

Mode

Functional Diagram

2 3GD T0

True OFF delay (Power OFF delay )

Relay

T = Set Time

T

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Frequency

Energizing Time

Timing Range

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Switching Frequency

@ rated max load

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

24 - 240 VAC/DC

-10 to +20%

(of )

2.5 VA

50-60 Hz

1s minimum

0.6s to 600s

± 5% of l a

+ 1%

2 C/O (DPDT)

5A @ 240 VAC / 28 VDC (Resistive)

Ag Alloy

1x10

1x10

7

5

Electrical : 1800 Operations / h

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-15° C to +60° C

-20° C to +70° C

95% (Rh)

Green LED Power ON

Flame Retardant UL94-V0

22.5 X 75 X 100.5

130 g

Base / DIN rail

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) Level 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 30g, 15ms

ORDERING INFORMATION

Cat. No.

Description

24V -off l owe e a

11

TM

Electronic Timer - Series Micon 225

• Single phase motor restart control timer with memory time,

under voltage trip and ON delay

Cat. No.

Parameters

Mode

Functional Diagram

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Timing Ranges

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Switching Frequency

@ rated max load

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Nonrepetitive shock

22LDT0

Motor Restart t < = Tm t > Tm

A1 - A2

STOP

START

15-18 t = Power Fail Time

Td

240 VAC

- 20% to +10%

50/60 Hz

4 VA

(of )

Memory Time (Tm): 0.2 to 6s, Delay Time (Td): 0.2 to 60s

Trip Volt: 176 VAC, +/- 6VAC, Hysterisis: 10 VAC max.

Max. 200 ms

± 5% of Full scale

+ 1%

1 C/O (SPDT)

5A @ 240 VAC / 28 VD C (Resistive)

Ag Alloy

1x10

5

1x10

7

Electrical : 1800 Operations / h

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

-15° C to +60° C

-20° C to +80° C

95% (Rh)

Green LED Power On, Red LED Relay On

Flame Retardant UL94-V0

22.5 X 75 X 100.5

130 g

Base / DIN rail

RoHS Compliant

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) Level 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) Level 30g, 15ms

ORDERING INFORMATION

Cat. No.

22LDT0

Description

240 VAC, Motor Restart Control

12

TM

Electronic Timer - Series Micon 225

MOUNTING DIMENSION (mm)

4.3

22.5

100.5

81.0

12.5

INSERT SCREW DRIVER

TO RELEASE DIN RAIL CLIP

DIN - RAIL (35mm symmetrical)

For -

2A5DT5, 2B5DT5, 2AODT5, 2ASDT0, 2ASDT1,

2BSDT0, 2BSDT1, 2AJDT0, 2AJDT1, 2AADT5,

20JDTT, 20NDTT, 2ANDT0, 23GDT0, 22LDT0

2A6DT6, 2B6DT6

CONNECTION DIAGRAM

2A5DT5, 2B5DT5, 2AADT5,

23GDT0, 2AODT5, 273DT5,

29ODT5, 25ADT5

2AJDT0, 2AJDT1

For -

273DT5, 29ODT5, 25ADT5

2ASDT0, 2BSDT0,

2ASDT1, 2BSDT1

20JDTT, 20NDTT

B1

A1 A2

Y1

V

V

S

B2

Y2

LOAD

L

N

2ANDT0

For ON Delay &

Interval Mode Selection

TERMINAL TORQUE & TERMINAL CAPACITY

Ø 3.5 4.0mm

AWG

Torque 0.6 N.m (6 Lb. in)

Terminal Screw - M3

2

1 x 1 - 4 mm Solid Wire / Single Wire Ferrule

2

2 x 0.5 - 2.5 mm insulated twin type Ferrule

1 x 16 to 12

22LDT0

2A6DT6, 2B6DT6

[for 1st 5 modes both the contacts are delayed & for 6th mode 1st contact (15, 16, 18) is delayed &

2nd contact (25, 26, 28) is Instant]

13

TM

Electronic Timer - Series Micon 350

• Selectable ON delay/Retentive ON delay

• Inbuilt instant contact with 2C/O

Cat. No.

Parameters

Mode

Functional Diagram

3 6ED 7

3

D l /R e iv ON e y S l t bl

3ED 7

Supply Voltage ( )

Supply Variation

Frequency

Timing Ranges

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Switching Frequency

@ rated max load

Operating Temperature

Storage Temperature

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

ORDERING INFORMATION

Cat. No.

De c ipti on

36EDT7

33EDT7

37EDT7

24V AC/DC, ON Delay/Retentive ON Delay

110V AC, ON Delay/Retentive ON Delay

240V AC, ON Delay/Retentive ON Delay

MOUNTING DIMENSION (mm)

3 7ED 7

R

T

= Supply

R = Relay

4 C/ DC

- 20% to +10% (of )

5 0/6 H

R

1 t1 t2 tp1

10 VAC

1 00 ms (Max.)

± f

± 1% d

AgCdO

1x10

5

1 000 ra i / (Ma )

-1 0 ° C o 55° C

-2 0 o 70° C e L N Re L e y r

Compliant r tp2 t3

T = Set Time

T = t1 + t2 + t3 tp1, tp2 = Power down region

2 40 VA C

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

CONNECTION DIAGRAM

S AN T

TERMINAL TORQUE & CAPACITY

3.5 mm

AWG

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

2

1 x 0.2 - 3.3 mm Solid Wire / single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

14

TM

Electronic Timer - Series Micon 480

• Multi-function, Asymmetrical ON/OFF, and Star-Delta timers

• Wide operating voltage range

• Front access for frequent change of parameters

• Universal mounting

Cat. No.

Parameters

Mode

Functional Diagram

40MFS0

Multi-function

MODE FUNCTION

T-Set Time

ON DELAY

R

T

INTERVAL

CYCLIC

R

T

R

T T

CONTROL SIGNAL

SIGNAL

OFF DELAY

R

40AFS0

Asymmetrical ON/OFF

(R1, R2)

T

ON

T

OFF

T

OFF

= OFF Time

40SFS0

Star-Delta

Relay

Relay

T T = Set Time

Tp

Tp = Pause Time

Supply Voltage ( )

Supply Variation

Frequency

Timing Ranges

Pause Time

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Switching Frequency

@ rated max load

Operating Temperature

Storage Temperature

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

24 - 240 VAC/DC

- 20% to + 10% ( of )

5 0/6 H

0.1s to 10h

N. A.

100 ms (max.)

0.1s to 10h (ON & OFF Both)

± 5% of Full scale

± 1%

2 C/O

5A (resistive) @ 240 VAC / 28 VDC

1x10

5

1000 operations/h (Max.)

-10 ° C to +55° C

-20 ° C to +70° C

Green LED Power ON, Red LED Relay ON

Flame Retardant UL94V0

48 X 48 X 95

114 g

Base / DIN Rail, Flush with 11 or 8 pin Universal or Solderable socket

110/240 VAC

0.3s to 120s

60ms, 90ms, 120ms, 150ms

Star - 1 'NO', Delta - 1 'NO'

Red 1 ON, Red 2 ON

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

ORDERING INFORMATION

Cat. No.

40MFS0

40MFE0

Description

24-240 VAC/DC, Multi-function with Signal Off Delay, 2 C/O, 11 Pin

24-240 VAC/DC, Multi-function, 2 C/O, 8 Pin

40AFS0

24-240 VAC/DC, Asymmetrical ON/OFF, 2 C/O, 11 Pin

40SFS0

24-240 VAC, Star-Delta, 1 NO (Star) + 1 NO (Delta), 11 Pin

46OFE8

43OFE8

47OFE8

24 VAC/DC, On Delay, 1 instant + 1 delayed C/O, 8 Pin

110 VAC, On Delay, 1 instant + 1 delayed C/O, 8 Pin

240 VAC, On Delay, 1 instant + 1 delayed C/O, 8 Pin

15

TM

Electronic Timer - Series Micon 480

MOUNTING DIMENSION (mm)

CONNECTION DIAGRAM

For : 40MFS0

For : 40AFS0

For : 40SFS0

For : 40MFE0

For : 47OFE8, 43OFE8, 46OFE8

INST DLYD

16

TM

Electronic Timer - Series Micon 780

• Selectable Dual-voltage: 110/240V AC,240/415V AC and 24V AC/DC

• Multi-function, Asymmetrical ON/OFF, and Star-Delta timers

• Selectable Contacts: One instant and One / Two delayed

• Large knobs for ease of setting

Cat. No.

Parameters

Mode

Functional Diagram

70MDT0

Multi-function

INSTANT RLY

70ADT0

Asymmetrical ON/OFF

RELAY R2 (INSTANT)

T

ON

T

OFF

T

OFF

= OFF Time

70SDT0

Star- Delta

15-18

25-28

Ts

P

Ts = Set Time

P = Pause Time

Supply Voltage ( )

Supply Variation

Frequency

Timing Ranges

Pause Time

Reset Time

Accuracy

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Switching Frequency

@ rated max load

Operating Temperature

Storage Temperature

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

110 VAC / 240 VAC

- 20% to +10%

(of )

50/60 Hz

0.1s to 10h

N.A.

100 ms (max.)

0.1s to 10h (ON & OFF Both)

0.3s to 120s

60ms, 90ms, 120ms, 150ms

± 5% of Full scale

± 1%

1 Instant + 1 Delayed or 2 Delayed C/O (Selectable) Star - 1 'NO', Delta - 1 'NO'

For-110/240 V AC Model - 10A (resistive) @ 240 VAC & For-240/415 V AC Model - 5A (resistive) @ 415 VAC

AgSnO

1x10

5

1000 operations/h (Max.)

-10 ° C to +55° C

-20 ° C to +70° C

Green LED Power ON, Red LED Relay ON

Flame Retardant UL94V0

55 X 78 X 104

210 g

Base / DIN Rail

Red 1- ON, Red 2- ON

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

ORDERING INFORMATION

Cat. No.

70MDT0

74MDT0

76MDT0

Description

110/240 VAC, Multi-function

240/415 VAC, Multi-function

24 VAC/DC, Multi-function

70ADT0

74ADT0

76ADT0

70SDT0

74SDT0

110/240 VAC, Asymmetrical ON/OFF

240/415 VAC, Asymmetrical ON/OFF

24 VAC/DC, Asymmetrical ON/OFF

110/240 VAC, Star-Delta

240/415 VAC, Star-Delta

17

TM

Electronic Timer - Series Micon 780

MOUNTING DIMENSION (mm)

CONNECTION DIAGRAM

INSTANT

TERMINAL TORQUE & CAPACITY

INSTANT

,

(70SDT0)

(74SDT0)

STAR DELTA

18

Electronic Timer - Series Staircase

TM

• Compact 17.5mm wide with 10 operating modes

• Time Range: 0.5min - 20min

• Long Run mode with time range from 0.5h - 20h

• Functions with pre-warning & maintenance mode available

• Switch indications (glow-lamps / pilot lamps) upto 50 mA

• 3 wire & 4 wire configurations

Cat. No.

Supply Voltage ( )

Supply Variation

Frequency

Signal Supply Range

Power Consumption (Max.)

Modes

27B1C3B1

230 VAC

- 25% to +15% (of )

50/60 Hz

As per Supply Voltage ( )

3 VA

1. Staircase Relay, 2. Staircase Relay with Pre-Warning, 3. Staircase Relay with Cut-Off, 4. Staircase Relay with Cut-

Off & Pre-Warning, 5. Timing Step with Release Delay & Cut-Off, 6.Timing Step with Release Delay, Cut-Off & Pre-

Warning, 7. Long Run, 8. Long Run with Pre-Warning, 9. Step Relay, 10. Permanent ON, 11. Maintenance Mode

0.5m, 2m, 4m, 6m, 9m, 15m, 20m (The unit will change from minutes to hours for ‘Long Run’ modes ) Timing Ranges

Signal Sensing Time

Maintenance Mode

Accuracy:

Setting Accuracy

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

LED Indication

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

EMI/ EMC

Harmonic Current Emissions

ESD

Radiated Susceptibility

Electrical Fast Transients

Surges

Conducted Susceptibility

Voltage Dips & Interruptions

Conducted Emission

Radiated Emission

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Non-repetitive shock

ORDERING INFORMATION

Cat. No.

27B1C3B1

27C1C3B1

CONNECTION DIAGRAM

± 5% of Marking

± 1%

1 NO (Pole is internally short with ‘Live’)

16A @ 230 VAC

AgSnO

1X10

5

1X10

7

Green LED Power ON, Yellow LED Relay ON

-10°C to +60°C

-20°C to +70°C

95% (Rh)

Flame Retardant UL94-V0

18 X 60 X 85

70 g

Base / DIN rail

RoHS Compliant

IEC 60669-2-3

IP 20 for Terminals, IP 40 for Enclosure

IEC 61000-3-2

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-11

CISPR 14-1

CISPR 14-1

Ed. 3.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 3.0 (2006-02) Level IV

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level III (On Supply) & Level II (On Signal)

Ed. 2,2 (2006-05) Level III

Ed. 2.0 (2004-03) Performance Criteria B/A

Ed. 5.0 (2005-11) Class A

Ed. 5.0 (2005-11) Class A

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms

Description

230 VAC, Staircase Timer (10 Modes), 1 NO, Light Grey Casing

230 VAC, Staircase Timer (10 Modes), 1 NO, Dark Grey Casing

For Mounting Dimensions, Terminal Torque & Terminal Capacity refer page no. 5 & 6

19

Electronic Timer - Series Staircase

TM

FUNCTIONAL DIAGRAMS FOR 27B1C3B1 & 27C1C3B1

1. STAIRCASE RELAY 2. STAIRCASE RELAY WITH PRE-WARNING

<5s <5s

<5s <5s

<5s <5s

<5s

T

T

T

On initial signal, the output closes & timing starts for the preset duration. Subsequent signals during the run time will extend the time duration by the full preset value

3. STAIRCASE RELAY WITH CUT-OFF

<5s

<5s <2s <2s

<5s

T

10 10

T

T

10 10

4. STAIRCASE RELAY WITH CUT-OFF & PRE-WARNING

=

<5s <5s <2s

<5s

T T

T

T

T

On initial signal, the output closes & timing starts for the preset duration. Subsequent signals during the run time will extend the time duration by the full preset value. If a signal of duration more than 2 seconds is applied, the output contacts open instantly.

5. TIMING STEP WITH RELEASE DELAY & CUT-OFF

<5s

<5s <2s

<2s <5s

T

10 10

T

T

10 10

6. TIMING STEP WITH RELEASE DELAY & CUT-OFF &

PRE-WARNING

<5s <5s <2s <5s

T

10 10

T

T T

On initial signal, the output closes & timing starts for the preset duration. During run time, if a signal of duration less than 2 seconds is applied, it is ignored. If the duration is more than 2 seconds, the output contacts open instantly

7. LONG RUN

<5s

T

10 10

T

8. LONG RUN WITH PRE-WARNING

=

<5s

10

10

T

10 10

T

10 10

T T

On initial signal, the output closes & timing starts for the preset duration. On completion of the time duration the output contacts open. Any signal during the run time is ignored.

9. STEP RELAY

<5s <5s <5s <5s

10. PERMANENT ON

T

10 10

20

After every signal, the output changes state, alternately switching from open to closed & vice versa.

In this mode the output contacts are permanently closed until the mode is changed and the device is reset.

11. MAINTENANCE MODE

If the relay is OFF and a signal of duration more than 5 seconds is applied, the maintenance mode is activated. In this mode the output contacts close for a duration of 60 minutes after which it opens. During this period if a signal of duration more than 5 seconds is applied, the maintenance mode is interrupted and the output contacts open. The mode can be activated from any one of the modes (Mode 1, 2, 3, 4, 5, 6, 9) provided that the output contacts are open.

With Warning:

Without Warning:

1 hr

10

10

< 1 hr

10 10

1 hr < 1 hr

Pre-Warning:

On completion of the set time duration the output blinks once & again blinks twice after a delay of 10 seconds and the contacts open after a further delay of 10 seconds.

®

Digital Timer

• Compact 17.5 mm

• Multi-voltage, Multi-function(8 or 17)

• 3 digit LCD for Preset time and Run time

• Option to select Up/Down counting

• Tamper proof with key lock function

• All settings accomplished with only two keys

• Up to 999 Hours

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Timing Ranges

Repeat Accuracy

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Switching Frequency

@ rated max load

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

Degree of Protection

Humidity (Non Condensing)

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Vibration

V0DDTS1, V0DDTS

24 - 240 VAC/DC

-15% to +10%

(of )

50 / 60 Hz, + / - 2 Hz

10 VA

0.1s to 999h

+/- 0.5% of selected range

1 C/O (SPDT)

8 A (resistive) @ 240 VAC / 24 VDC

2 NO (DPST)

1x10

5

7

2x10

1800 Operations / h

Rated Voltage (Ue): 125/240 V, Rated Current (Ie): 3/1.5 A

Rated Voltage (Ue): 125/250 V, Rated Current (Ie): 2/0.22/0.1 A

-10° C to +55° C

-20° C to +65° C

F a e Re r 4V 0

17 .5 X 89 X 76

85 g

Base / DIN rail s

RoHS Compliant

0

95% ( Rh ) l

V0DDTD1, V0DDTD

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

ORDERING INFORMATION

Cat. No.

V0DDTS

V0DDTD

V0DDTS1

V0DDTD1

Description

24-240 VAC/DC, 8 Functions, 1C/O

24-240 VAC/DC, 8 Functions, 2 NO

24-240 VAC/DC, 17 Functions, 1C/O

24-240 VAC/DC, 17 Functions, 2 NO

MOUNTING DIMENSION (mm)

CONNECTION DIAGRAM

Supply Connections V0DDTD1,

V0DDTD

V0 DTS1,

A1 15 25 15

B1

18

A2 18

[email protected]

28

OPTIONAL

LOAD >1mA

TERMINAL TORQUE & CAPACITY

Torque 0.54 N.m (5 Lb. in)

Terminal Screw M2.5

Ø3.5 mm

AWG single wire ferrule

2

2 x 0.2 - 0.5 mm Insulated with twin ferrule

1 x 22 to 14

[email protected]

16

21

Digital Timer

®

FUNCTIONAL DIAGRAMS FOR V0DDTS1 & V0DDTD1

22

U

ON DELAY [0]

R

T

Timing commences when supply is present.R energizes at the end of the timing period.

T

CYCLIC OFF/ON

{OFF Start, (Sym, Asym)} [1]

U

R

TOFF TOFF

TON TON

T-ON and T-OFF can be same or different. The relay(R) keeps on changing its status till power is removed.

CYCLIC ON/OFF

{ON start, (Sym, Asym)} [2]

U

R

TON

TOFF

TON

TOFF

This function is quite similar to the function ‘1’ but initially the relay(R) is ON for period

T-ON after the power is applied.

IMPULSE ON

ENERGIZING [3]

U

R

T T

After power ON, R energizes and timing starts. R de-energizes after timing is over.

ACCUMULATIVE DELAY

ON SIGNAL [4]

U

B1

R t1 t2

T+t1+t2 T

Time commences as supply is present and switch B1 is open. Closing switch B1 pauses timing. Timing resumes when switch B1 is opened again. R energizes at the end of timing.

U

ACCUMULATIVE DELAY

ON INVERTED SIGNAL [5]

B1

R t1 t2

T+t1+t2 T

Time commences as supply is present and switch B1 is closed. Opening switch B1 pauses timing. Timing resumes when switch B1 is closed again. R energizes at end of timing.

U

ACCUMULATIVE IMPULSE

ON SIGNAL [6]

B1 t1 t2

R

T+t1+t2

When supply is ON, R energizes. When switch B1 is closed timing is suspended and remains suspended till switch B1 is opened again. Interrupting supply resets timer.

T

SIGNAL ON DELAY [7]

U

B1

R

Timing starts when switch B1 is closed. R energizes at end of timing period and de-energizes when B1 is opened.

T

U

INVERTED SIGNAL

ON DELAY [8]

B1

R

T

Timing will commence when supply is present and switch B1 is open. R energizes after timing .If B1 is closed during timing period, timing resets to the beginning of cycle.

SIGNAL

OFF DELAY [9]

U

B1

R

R energizes when switch B1 is closed. Timing commences after S is opened and then the relay de-energizes.

T T

IMPULSE ON/OFF [A]

U

B1

R

T T T

R energizes for the timing period when B1 is opened or closed. When timing commences, changing state of B1 does not affect R but resets timer.

SIGNAL OFF/ON [b]

U

B1

R

When switch B1 is closed or opened for preset time ,T, the relay changes its state after time duration T.

T

U

LEADING EDGE

IMPULSE1 [C]

B1

R

T

When B1 is closed, output relay energizes until timing irrespective of any further action of B1.

T

T T

U

LEADING EDGE

IMPULSE2 [d]

B1

R

T when switch B1 is closed, and remains closed output relay energizes until timing is over. If B1 is opened during timing, R resets.

TRAILING EDGE

IMPULSE1 [E]

U

B1

R when B1 is opened, R energizes and de-energizes when timing is over. If B1 is closed during timing R resets.

T

U

TRAILING EDGE

IMPULSE2 [F]

B1

R

T

When switch B1 is opened, R energizes and will de-energize when timing is over. If B1 is pulsed during timing period it will have no effect on R.

T

U

DELAYED

IMPULSE [G]

B1

TON

R

TOFF when switch B1 is closed, TOFF starts . Relay energizes at the end of TOFF period. Then,

TON starts irrespective of signal level and relay de-energizes at the end of TON period.

Digital Timer

®

FUNCTIONAL DIAGRAMS FOR V0DDTS & V0DDTD

P : A1- A2

P: Power-On operation

ON DELAY ( A )

CYCLIC OFF/ON

{OFF Start, (Sym, Asym)} ( b)

CYCLIC ON/OFF

{ON Start, (Sym, Asym)} ( C)

SIGNAL ON/OFF ( d)

SIGNAL OFF DELAY ( E)

INTERVAL ( F)

SIGNAL OFF / ON ( G)

S : B1

R :

T

S

:

B1

T OFF T ON T OFF T ON

R

:

S

:

B1

T

ON

T OFF T

ON

T

OFF

R

:

S

:

B1

R

:

T T T T

S

:

B1

R

:

S

:

R

:

B1

T

T

S

:

B1

R

:

T T T T

ONE SHOT OUTPUT ( H)

S

:

R

:

B1

T

1 SEC.

Note: 1. For Power-On operation (P) connect the terminal B1 to A1 permanently.

2. If the Signal (S) changes during the Timer Duration (T), it does not change the output relay but re-triggering

takes places and the Timer Duration is extended.

23

Synchronous Timer - Series EM 1000

• Time delay is independent of normal voltage and temperature fluctuations

• Black pointer gives clear indication of the time set on the calibrated dial

while the red one indicates the time left to complete the cycle

• Automatic reset on de-energisation of the clutch coil

• Base mounting or flush mounting versions

• No-volt feature available

Mode

Functional Diagram

On - Delay

Supply Variation

Frequency Variation

Power Consumption (Max.)

Timing Range

Repeat Accuracy

Contact Rating

Switching Frequency

Operating Temperature

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Terminal Connection

Degree of Protection

R

T

= Supply, R = Relay, T = Set Time

- 20% to +10%

95% to 105%

10 VAC

0.15s to 120h

± 0.5% of FSR at constant Frequency

1 Inst + 1 delayed - AgCdO

1 Inst + 2 delayed - AgCdO (Optional)

6A (resistive) @ 250 VAC

3000 operations/hr. (Max.)

- 5°C to + 45°C

Conforms to IP30 - IS 13947.

96 X 96 X 100

530 g

Flush & Base

1– 2.5 mm² solid/ stranded

IP20

ORDERING INFORMATION

B

Timing Ranges(SR)

N

P

Q

R

S

T

V

J

K

L

M

B

C

D

E

F

G

H

0.15 - 3.0

SEC

1.5 - 30 SEC

0.15 - 3.0 MIN

1.5 - 30 MIN

0.15 - 3.0 HRS

1.5 - 30 HRS

0.3 - 6.0 SEC

3.0 - 60 SEC

0.3 - 6.0 MIN

3.0 - 60 MIN

0.3 - 6.0

3.0 - 60

HRS

HRS

0.6 - 12 SEC

6.0 - 120 SEC

0.6 - 12 MIN

6.0 - 120 MIN

0.6 - 12 HRS

6 - 120 HRS

X

Y

Z

Timing Ranges(MR)

0.15 SEC.-3.0 HRS.

0.3 SEC.- 6.0 HRS.

0.6 SEC.-12.0 HRS.

Voltage

3 110V AC 50 Hz

4 240V AC 50 Hz

C 110V AC 60 Hz

D 240V AC 60 Hz

1

2

Delay

Standard ON delay

With ‘NO VOLT’

B

F

Mounting

Base Mounting

Flush (door) Mtg.

Contact

1 1 Inst + 1 Del C/O

2 1 Inst + 2 Del C/O

WIRING DIAGRAMS OF SERIES EM1000

Clutch

Instant Motor Delay

1

2

3

4

5 15

M

16

6

7

8 9

11

10

MOUNTING DIMENSION (mm)

96

Note : Panel Cutout 91mm Dia.

24

Panel Max. 10mm

100 mm 27

On - Delay (Retentive / No Volt)

R

<

< t1

< < t2

<

T = t1 + t2 + t3

< t3

<

<

3

2 4

1 5

0 6

GENERAL INDUSTRIAL CONTROL

BASE MOUNTING

Knob

Mounting Hole

25.5

15.5

84

96

Terminals

132

Synchronous Timer - Series EM 2000

• Time delay is independent of normal voltage & temperature fluctuations

• Large knob operating on a linear scale makes time setting easy

• Set time is indicated by a fixed pointer of the setting knob.

• Time left for completion of cycle is indicated by red pointer

• Wiring is quicker and easier as terminals are in the front of the unit

• All part subjected to wear & tear are made of 'Delrin' which has high

resistance to wear & tear and thus ensures longer life.

Mode

Functional Diagram

Supply Variation

Frequency Variation

Timing Range

Accuracy :

Repeat Accuracy

Contact Rating

Switching Frequency

Operating Temperature

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Terminal Connection

Degree of Protection

On - Delay

R

T

= Supply, R = Relay, T = Set Time

- 20% to +10%

95% to 105%

1s to 120s

± 2% of FSR at constant Frequency

1 delayed - AgCdO

2 delayed - AgCdO (Optional)

5A (resistive) @ 250 VAC

1000 operations / hr. (Max.)

-5°C to 45°C

Conforms to IP30 - IS 13947.

55 X 88 X 106

260 g

Base/DIN Mounting & can be mounted on vertical plane with maximum inclination of 15° from vertical.

1– 2.5 mm² solid/stranded.

IP20

ORDERING INFORMATION

C B 1

Timing Ranges

C

J

1.0 - 30 Sec

2.0 - 60 Sec

Q 4.0 - 120 Sec

Voltage

3 110V AC 50 Hz

4 240V AC 50 Hz

5 415V AC 50 Hz

Contact

5 1 Del C/O

6 2 Del C/O

WIRING DIAGRAMS OF SERIES EM2000

15

A1

M

A2

A1

M

A2

16 18 16

15

S1

18 26

25

S2

28

Note : Switch 2 operates before switch 1

MOUNTING DIMENSION (mm)

BASE/DIN MOUNTING

45.0 C/C

6.8

DIN RAIL

(35 mm SYMMETRICAL)

96.5

106.0

5.5

55.0

25

Glossary

Operating Voltage:

Input Supply required for operation.

Supply Variation:

Allowable variation in input power supply for satisfactory operation.

Delayed Contacts:

A contact in a timer that changes state at the end of time that has been set.

Instantaneous Contact:

A contact that changes state as soon as power is switched on to the timer.

Electrical Life:

The number of operations that the contact can be expected to make or break at the rated electrical load.

Reset Time:

Time taken by the timer to start a new cycle.

Repeat Accuracy:

It indicates how consistently the device will repeat the time. It is more important where uniform processing time cycles are required.

Rated Current:

A current that can flow continuously through the closed contact.

Contact Rating:

Voltage and current, which can switch under specified conditions.

Storage / Ambient Temperature:

Temperature surrounding the product.

Power Consumption:

Power absorbed by the unit for its own satisfactory functioning.

Mounting:

The type of placement of the unit (Base/Din/Flush).

No-volt protection (Retentive Timer):

Timers are available with retention ensuring that elapsed time is not cancelled when the supply is interrupted during the timing cycle.

26

Operating Modes / Functions

MULTIFUNCTIONAL

INST. RELAY

ON DELAY

RELAY

T

RELAY

CYCLIC

T T

RELAY

INTERVAL

T

OFF DELAY

CONTROL

SIGNAL

RELAY

T

STAR - DELTA

• Delay on Energisation (ON Delay): The set time (Delay) starts when the timer receives supply. The output relay energises at the end of the pre-set time

• Cyclic Instant (Equal ON/OFF): On energisation, relay output switches ON and OFF repeatedly for the set time. Cycle starts with relay in energised condition. When supply is switched OFF , the relay is reset.

• Interval Timer: On energisation of Timer, Output relay changes the state for the time set. After completion of set time, output relay de-energises. By switching off the supply, the Timer gets de-energised & is ready for the next cycle of operation.

• (Signal)-OFF delay: Timer is energised and relay is in OFF condition. When control input is given through control contacts, relay is energised. Delay period commences when control input is removed. At the end of set time, relay is de-energised and load is disconnected.

Relay

Relay

T

Set Time

Tp

Pause Time

ASYMMETRICAL

ON/OFF

Relay R1, R2 Ton

Toff

Relay R2

DLY

INST

• Star - Delta: The timer has a fixed transition time from Star to

Delta connection. On energisation, the output star relay energises instantly. After completion of preset delay time, output Delta relay energises after fixed pause time. This pause time (60, 90,

120, 150 ±20 ms ) provides the shortest possible 'current off' pause and simultaneously ensures smooth change over.

• Asymmetrical ON/OFF (Cyclic Instant): ON/OFF, can be independently selected from 0.1 Sec. to 10 Hrs. On energisation, relay output switches on and off repeatedly for the respective set times. Cycle starts with relay in energised condition. By removing supply, the relay is reset.

TRUE OFF DELAY

(POWER OFF DELAY)

MODE FUNCTION

Relay

T

ON DELAY

(RETENTIVE/NO VOLT)

MODE FUNCTION

Relay

<

< t1

< < t2

<

T

T= t1 + t2 + t3

< t3

<

<

• True OFF Delay: On energisation the Relay O/P is in ON Position.

Timing delay period commences when supply to the True OFF

Delay Timer goes OFF. The O/P Relay de-energises at the end of pre-set time.

• ON Delay (Retentive): The set time (Delay) starts when timer receives supply. The output relay energises at the end of the preset time. If power fails during set time, the elapsed time will retained by timer. Upon resumption of power, remaining cycle will continue.

27

28

GIC

www.gicindia.com

TIME SWITCHES

Time Switch FM Series

Digital Time Switch

Astronomical Time Switch

Astronomical Time Switch

Lighting Automation with Using GSM Technology

Time Switch FM Series

• Modular construction

• Inbuilt over-ride facility

• High switching capacity

• Tamper proof sealing

• Analog & Digital version

• Daily/Weekly programming

• Graphical Program LCD

Cat. No.

Parameters

Supply Voltage

Frequency

Power Consumption (Max.)

Accuracy

Switching contact

Contact Rating

- Resistive

- Inductive (cosø = 0.6)

- Incandescent Lamp

Shortest Switching Time

- Daily

- Weekly

Power reserve

Memory locations

Storage Temperature

Manual Over-ride

Mounting

Weight (unpacked)

J648B1 (Analog Version)

240 VAC

50/60 Hz

2 VA

± 1.5 s/day at 20°C

1 C/O contact - AgCdO

16A @ 250 VAC, 0.25A @ 220VDC

8A @ 250 VAC, 0.1A @ 220 VDC

1350 W

D847B2 (Digital Version)

4.4 VA

± 1 s/day at 20°C

16A @ 250 VAC

4A @ 250 VAC

1350 W

1min

1min

10 years from Factory at 20°C

20

ORDERING INFORMATION

Cat. No.

Description

J648B1

J848B1

J638B1

J838B1

D847B2

FM/1 QT

FM/1 QW

FM/1 QT

FM/1 QW

Daily dial, 240 VAC, Base / DIN Mounting

Weekly dial, 240 VAC, Base / DIN Mounting

Daily dial, 110 VAC, Base / DIN Mounting

Weekly dial, 110 VAC, Base / DIN Mounting

FM/1 Digi20 Plus Weekly / Daily, 240 VAC, Base / DIN Mounting

Note: For Flush Mounting model replace B by F in Cat. No.

F

15min

2h

150h

N. A.

- 20°C to + 55°C

Provided

Flush, Base / DIN rail

185 g

TIME SETTING:

Rotate the switching Dial in clockwise direction until the current time (day / time incase of weekly model) is almost opposite to the marking arrow F. For fine adjustment rotate the minute hand in the clockwise direction until the clock shows the current time.

PROGRAMMING:

Required Switch ON time is set on the Switching Dial by radially pulling outwards the corresponding black segments. Each segment on daily dial corresponds to 15 mins. & on weekly Dial corresponds to 2 hours.

MOUNTING DIMENSION (mm)

72.0 SQ 52.0

39.5

MAX. 4.5

CONNECTION DIAGRAM

72.0

20.50

34.50

14.70

SCREW

P

N

66.0

Base Mounting Flush Mounting

TERMINAL TORQUE & CAPACITY

4.0 mm

AWG

1

(Time Switch)

TS

2 3

NO NC

4 5

I

Permanent

'ON'

As per

Programme

LOAD

Torque 1.1 N.m (10 Lb. in)

Terminal Screw - M 3.5

2

1 x 0.2 - 5 mm Solid Wire / single wire ferrule twin ferrule

1 x 24 to 10

0

Permanent

'OFF'

30

Digital Time Switches

TM

&

• Precise time programming for Daily/Weekly/Pulse switching

• 25 ON/OFF programs

• Weekend exclusion (FRI SAT or SAT SUN) and Weekly OFF programming

• LED indication of Relay status

• 12/24 h display formats

• 6 years battery reserve

• Simple Reset & Manual override

• DST Feature Available

Cat. No.

Parameters

Supply Voltage & Frequency

Number of Modes & Description

Number of Programs

Minimum Switching Time

AC - 15

Utilization Category

DC - 13

Power Consumption (Max.)

Operating Temperature

Storage Temperature

DST

Clock Accuracy

Power Reserve from Factory

Switching Contacts

Contact Rating

TM 67DDT0 ( ) 67DDT9 ( )

110 - 240 VAC, -20 % +10% , 50 / 60 Hz

Five

• AUTO

• ON AUTO

• AUTO OFF

• ON

• OFF -

-

-

-

-

Program Run

Instant ON up to next ON Program

Instant OFF up to next OFF Program

Continuous ON

Continuous OFF

Three

• AUTO

• ON

• OFF

-

-

-

Program Run

Continuous ON

Continuous OFF

25 ON/OFF

1min

Programs

16 Pulse Programs

(Ex - 0,1,2,3,4,5,6,7,8,9, a, b, c, d, e, f)

1s

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.11 A

6 VA

-10°C to + 55°C

-10°C to + 60°C

Settable ( 1 Hour)

± 2 s/day max. over the Operating Temperature range

6 Years

1 C/O (SPDT)

Resistive: - 16A (For 'NO') & 5A (For 'NC') @ 240 VAC / 24 VDC

Inductive (cos ø = 0.6) :- 6 A @ 250 VAC

Incandescent Lamp: - 1000 W

3x10

4

Ag Alloy

50 X 10

3

Electrical Life

Contact Material

Mechanical Life

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

Certification

F a e Re r

36 X 65 X 90

120 g

Ba D N r l

V fo s

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Applications

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-11

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Ideal for Lighting applications like street lighting,

Advertising Displays, Glowsigns. Also can be used for

Air conditioners / Coolers, Geysers, conveyors, pumps etc.

Ideal for Siren, School bell application

ORDERING INFORMATION

Cat. No.

Description

6 7D DT 0

6 7D DT 9

110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)

110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)

TIME & DAY SETTING:

Press RST key. Press key & keep it pressed. Then press D + key to set running day. Press H + key to set running hour & press M + key to set running Minute.

FUNCTIONS OF KEYS:

PRG

D +

H +

: To enter the programing mode & selection of ON/OFF programs

: To increment & select any particular day / combination of days

: To increment hours, M + : To increment minutes

: To set the clock & change the time format (AM / PM or 24 Hour format)

RST : To reset programs & clock

MAN / (-) key : For mode setting (Manual override) / to decrement day, hour & minute in programming mode / DST

PROGRAMMING:

To set a program - Press PRG key.

Set 1 ON time, day, then 1 OFF time, day with the help of D+, H+ & M+ keys.

We can set total of 25 ON & 25 OFF programs.

DST:

Press H+ & M+ keys simultaneously to enter the DST mode.

To enable DST, press M+ key once.

To disable DST, press M+ key again.

PROGRAMMING:

To set a program - Press PRG key.

(a) If pulse is common or the same, set pulse before the ON time (b) If pulse time is different for different programs, set the ON time first and then set different pulse values for each programme

31

Astronomical Time Switch

• Astronomical Time Switch in 35mm size

• Latitude/Longitude precise to the minute with time zone

• Sunrise/Sunset or Twilight rise/set trigger modes

• Ease of programming & navigation

• DST, Offset, OFF Hours, Weekly OFF features

• 12/24 Hour display format

• 6 years battery reserve

• Easy Manual Override

• Ideal for Outdoor & Street lighting applications

T2DDT7 Cat. No.

Parameters

Supply Voltage & Frequency

Number of Modes & Description

Programming

Minimum Switching Time

AC - 15

Utilization Category

DC - 13

Power Consumption (Max.)

Operating Temperature

Storage Temperature

LCD Display

Clock Accuracy

Power Reserve from Factory

Switching Contacts

Contact Rating

Electrical Life

Contact Material

Mechanical Life

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

Certification

110 - 240 VAC, -20 % +10% , 50 / 60 Hz

Three

• AUTO

• ON AUTO

• AUTO OFF

-

-

-

As per user defined program settings

Manual ON up to next auto event

Manual OFF up to next auto event

Based on:

1) Latitude/Longitude precise to the minute with time-zone

2) Option for both Sunrise/Sunset & Twilight rise/set trigger

3) DST feature (1 Hour) with indication on screen

4) Weekly OFF

5) Offset for rise/set

6) OFF-Hours

1min

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.11 A

6 VA

-10°C to + 55°C

-10°C to + 60°C

3 Lines Text LCD

± 2 s/day max. over the Operating Temperature range

6 Years

1 C/O (SPDT)

Resistive: - 16A (For 'NO') & 5A (For 'NC') @ 240 VAC / 24 VDC

Inductive (cos ø = 0.6) :- 6 A @ 250 VAC

Incandescent Lamp: - 1000 W

3x10

4

Ag Alloy

50 X 10

3

F a e Re r

36 X 65 X 90

1 10 g

Ba D N r l

RoHS Compliant

V fo

TM s

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Applications

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-11

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC) n o , i c l t a us

.

ORDERING INFORMATION

Cat. No.

Description

T2DDT7

110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)

ESC OK

FUNCTIONS OF KEYS:

ESC : Previous Menu / Undo Change

: Menu scroll up / Increase parameter value / View Output OFF time in standby mode

OK

RST

: Menu scroll down / Decrease parameter value / View Output ON time in standby mode

: Enter programming mode / selecting a particular parameter to edit / applying & confirming changes

: Resets clock & other programs & settings to default

MAN : For mode setting (Manual override)

: Exit programming mode / 12 or 24 Hour clock mode selection in standby mode

RST MAN

32

Astronomical Time Switches

• Dynamic and accurate control based on

astronomical mathematics

• Sunrise / Sunset or Twilight rise / set trigger

• Yearly programming with Season mode,

DST, Offset, Off hours, Weekly Off enabled

• Protection against under voltage and over voltage

• Alternate Mode with Auto load changeover feature

• Three independent channel outputs

TM

• Active Phase selection

• Manual override facility

• Single phase and three phase versions

• Modbus Communication

• User friendly software for device configuration

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Storage Temperature

Operating Temperature

Switching contacts

Electrical Life

Mechanical Life

Shortest switching time (daily)

Power reserve (for clock only)

Clock deviation

DST

Display

Under / Over Voltage Trip Level

Trip time for Under / Over Voltage

Recovery time

Mounting

Dimensions (W x H x D) (in mm)

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

Degree of Protection

Pollution Degree

T2DDT0

110-240 VAC, 50/60Hz

-20% to +15%

(of )

8VA @ 300 VAC

-10°C to + 60°C

-10°C to + 50°C

2 NO, 8A (resistive load) @ 240 VAC and

5A (resistive load) @ 30 VDC

10 5

7

1min (1 s for pulse)

1000 h

± 1 s per day over the operating temperature range settable

Backlit LC Graphics display for diagnostic view

N. A.

N. A.

N. A.

Base / DIN rail

72 X 90 X 67

T3DDT0

110-240 VAC 3 Phase 4 wire (P-N) , 50/60Hz

3 NO, 8A( resistive load) @ 240 VAC and

5A (resistive load) @ 30 VDC

Settable UV: 0 - 220 V & OV: 130 - 330 V

5 - 16 Sec.

1 - 4 Sec.

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

IP 20 for Terminals, IP 40 for Enclosure

II

Certification

RoHS Compliant

Weight (unpacked)

190 g 208 g

ORDERING INFORMATION

Cat. No.

Description

T2DDT0

T3DDT0

TGDDT6

GFDNN3M

GFDNN2S

GFDNN1

110-240 VAC, 1 Phase, 2 NO (SPST)

110-240 VAC, 3 Phase 4 wire (P-N), 3 NO (SPST)

Windows based application software for Astro

Memory card

Serial interface cable

USB interface cable

Q1-A

Q3-A

26-10-09

11:45

Q2-A

MON

ESC

Screen No. 1

DD/MM/YY

26/10/09

HH : MM

11 : 45

TIME & DAY SETTING :

1) Power ON the Astro. The screen No.1 will appear.

2) Press ESC key.

3) Set the cursor on "SETTINGS" with help of Z keys and press OK.

4) Set the cursor on "CLOCK" with help of Z keys and press OK.

5) Set the cursor on "DATE / TIME" with help of Z keys and press OK. Then screen No.2 will appear.

6) Press Z1 or Z3 key to locate the cursor at "DAY" parameter position. Then press "ALT" key to edit the value of Day. When user presses this key, the upper digit of the Day parameter start blinking as to show it is selected. Press Z2 or Z4 key to increment or decrement the value of digit under edit.

Press Z1 or Z3 key to select next digit of the parameter. Now again press Z2 or Z4 key to increment or decrement the value of digit. If required value of the Day has edited then press OK key to set it & come on the screen No. 1 by pressing the ESC key.

7) Similarly select other individual parameters and modify them as per your requirement & save it as per the above given process.

Screen No. 2

LONGITUDE

E 000' - 00'

LATITUDE

N 00' - 00'

Screen No. 3

LATITUDE & LONGITUDE :

1) Go to menu by pressing "ESC" key

2) Set the cursor on "SETTINGS" with help of Z keys and press OK

3) Go to "LAT/LONG" using Z2 Key. Then screen No. 3 will appear.

The cursor blinks at E. Press ALT Key to go into edit mode.

Change the direction using Z2 or Z4 key once the required direction is set press ALT to set the direction. Jump to next character using either Z1 or Z3 key.

Press ALT again to enter into edit mode When user presses this key, the digit starts blinking.

Press Z2 ro Z4 key to increment or decrement the value of digit under edit.

Press Z1or Z3 key to select next digit of the parameter.

Now again press Z2 or Z4 key to increment or decrement the value of digit.

If the required value of latitude longitude has been edited then press OK key to save it.

GMT + 00 : 00

TIME ZONE :

4) Go to "CLOCK" and Press OK.

5) Select "TIME ZONE" and Press OK. Then screen No.4 will appear.

6) In the screen No. 4, edit sign, hour & minute as per your requirement. Then press OK to save

the changes & & come on the screen No. 1 by pressing the ESC key.

Screen No. 4

33

Astronomical Time Switches

Digital Time Switches

TM

&

TM

MOUNTING DIMENSION (mm)

For: T2DDT0 & T3DDT0

72.0

CONNECTION DIAGRAM

Supply

240 VAC

50/60 Hz

N

P

250mA

L N

110 -240 VAC

50 / 60 Hz

For: T2DDT0

DEL

Z4

ALT

Z1 Z3

PHASE

ESC

Z2

OK

Astro

OUTPUT

2 X RELAY / 8A

Q1 Q2

LOAD

MC1 MC2

1. MC1 : - Coil of Contactor 1

2. MC2 : - Coil of Contactor 2

TM TM

Crono, Pulse & Astro Mini

MOUNTING DIMENSION (mm)

36.0

L N

17.0

65.0

Supply

3 -Phase

4 wire

240 VAC

50/60 Hz

N

B

Y

Ph

R

Ph

250mA

R Y B N

110 - 240 V

Ph - N

50 / 60 Hz

AC [ 3Ph 4 Wire ]

For: T3DDT0

DEL

Z4

ALT

Z1

Z3

ESC

Z2

OK

Astro

OUTPUT

3 X RELAY / 8A

R

Ph

Q1

Y

Ph

Q2

B

Ph

Q3

MR MY MB

1. MR: - Coil of Contactor 1

2. MY: - Coil of Contactor 2

3. MB : - Coil of Contactor 3

PRG D+ H+ M+

RST MAN

18 15 16

17.0

65.0

TERMINAL TORQUE & CAPACITY

3.5 mm

AWG

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5 single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

34

P

N

CONNECTION DIAGRAM

L

(Time Switch)

TS

N 15

NO NC

18 16

LOAD

Lighting Automation with

TM

using GSM Technology

• Most of the "ASTRO" parameters can be set remotely using SMS queries. I.e. Output mode, Offset Hrs etc, UV, OV settings.

• Relay Output can be override remotely using SMS query.

• Energy Meter Functionality. Parameter like Load current, Supply voltage, Power, Energy can be known remotely.

• With the help of "Auto Error Code Update" following onsite error can be know remotely during output event.

- Under Voltage

- Over Voltage

- Over Current

- Output actuator short.

- Load Open

Cat. No.

Parameters

Supply Voltage ( )

Supply variation

Active phase selection

Operating Temperature

GSM Type

GPRS packet data

AT command set

Suitability

SMS type functionality

SIM Holder

Antenna

Antenna Impedance

Energy Measurement

Energy Measurement Accuracy

Current sensing range

CT ratio

LED Indications

Pulse Out rate

Auxiliary Output

General Port Connectivity

19D20B00 (ERT 5) 19D20A00 (ERT 1)

110-240 VAC 3 Phase 4 wire (P-N), 50/60Hz

-30%, +25% (of )

Yes o

C o

-15 to + 60 C

Dual band 900 / 1800 GSM

Class 10 coding scheme

N. A.

Data Call through GSM, SMS

Text, Cell Broadcast

Connected with the product

50

Yes

Class 0.5

5A

Settable up to 40

Tx, Rx, Network, Power, Pulse Out

3200 pulses / kWh

12 V DC, 200 mA

N. A.

1A

19C20C00

110-240 VAC, 50/60 Hz

Yes

GSM 7.05 & 7.07

No

N. A.

N. A.

N. A.

Tx, Rx, Network, Power, SIM Status

N. A.

N. A.

TTL port for connecting Time-switch

(Astro) USB through USB interface cable GFDNN1, RS232 through serial interface GFDNN2S, RS485 through TTL-RS485 converter

G7XDTR4"

Mounting

Enclosure

Colour

Dimension (W x H x D) (in mm)

Weight (unpacked)

Certification

EMI/ EMC

Harmonic Current Emission

ESD

Radiated Susceptibility

Electrical Fast Transients

Surge

Conducted Susceptibility

Voltage Dips and Interruptions

Radiated Emission

DIN / Base

4 Modular

RAL 7016

72 X 90 X 67

190 g

RoHS Compliant

IEC 61000-3-2 Ed. 3.0 (2005-11) Class A

IEC 61000-4-2 Ed. 1.2 (2001-04) Level II

IEC 61000-4-3 Ed. 3.0 (2006-02) Level III

IEC 61000-4-4 Ed. 2.0 (2004-07) Level IV

IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV

IEC 61000-4-6 Ed. 2.2 (2006-05) Level III

IEC 61000-4-11 Ed. 2.0 (2004-03) All seven levels

)

Note:

1. ERT5 & ERT1 can measure maximum 5A & 1A current respectively.

2. Maximum current measurement limit for ERT-5 is 200A & for ERT-1 it is 40A.

Ex: 1. For CT selection if current required to be measured is upto 200A then CT of 200:5 A ( CT ratio 40) needs to be used.

2. For CT selection if current required to be measured is upto 40A then CT of 40:1 A ( CT ratio 40) needs to be used.

ORDERING INFORMATION

Cat. No.

T3DDT0

Description

Astro time switch, 110-240 VAC 3 Phase 4 wire (P-N), 50/60Hz, 3 NO (SPST)

19D2000C

19D20B00

19D20A00

19C20C00

19A1000B

TGDDT6

Surge Suppressor

Astro GSM Module (GSM-ERT5), Remote Side

Astro GSM Module (GSM-ERT1), Remote Side

Astro GSM Module (GSM-RT), PC side

Communication Cable (TTL-TTL) between Astro & GSM Module

Windows based application software for Astro

35

Lighting Automation with

TM

using GSM Technology

• Maximum 5 valid users can access the system remotely, using GSM functionality.

• To avoid Remote module's SIM theft, "SIM PIN" facility can be enabled remotely using SMS query.

• To avoid changes in system configuration by unauthorized user amongst valid users, important SMS

queries are provided with "MODULE PIN" lock.

• Device supports for 12 to 14 digit mobile number. i.e. (10 Digit Mobile number + 2/3/4 digit country code).

CONNECTION DIAGRAM

36

1. MR: - Coil of Contactor 1

2. MY: - Coil of Contactor 2

3. MB: - Coil of Contactor 3

4. MRC1: - NO of Contactor 1

5. MRC2: - NO of Contactor 2

6. MRC3: - NO of Contactor 3

C. T.

TERMINAL TORQUE & CAPACITY

3.5 mm

AWG

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

2

1 x 0.2 - 3.3 mm Solid Wire / single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

HOUR METERS & COUNTERS

Hour Meter Series HM 36

Hour Meter Series HM 48

Digital Hour Meters

Impulse Counter Series CR 26

Digital Counters

GIC

www.gicindia.com

Hour Meter Series HM36

• Robust design with high degree of accuracy and compact size

• Frequency independent for AC applications

• Indicates operating time in hours and tenths with running indicators

• Totally sealed from dust and moisture

• Panel mountable with 7 bezel options

• Non-resettable

• 6 digit version with automatic recycle to zero

• Wide supply voltage range: 4-30V AC/DC, 10-80V DC & 90-264V AC

• Shock & Vibration Proof

AC Model HM36 Cat. No.

Parameters

Supply Voltage ( )

Frequency

Over Voltage & reverse polarity protection

Power Consumption (Max.)

Register

Read Out

Least Count

Accuracy

Vibration

Shock

Weight (unpacked)

Temperature

Humidity (Non Condensing)

Mounting

Termination

Degree of Protection

Approvals

DC Model HM36

90-264 VAC, 50/60 Hz

50/60 Hz

-----------------

10-80 VDC

10-80 N. A.

Protected for 2 times battery voltage and / or reverse polarity

0.5 VA

6 Digit (3.6mm)

99999.9

1/10 h

± 0.02% over entire range

10-80Hz with 20g max(SAE J1378)

55g @ 9-13ms (SAE J1378)

47g

0.25 VA

-40° C to +85° C

95% (Rh)

Panel

¼" [6.3] spade terminal

IP 65

SAE & NEMA 4X (Equivalent to IP65)

RoHS Compliant

Cat. No.

LA21F1

LA22F1

LA23F1

LA24F1

LA25F1

LD11F1

LD12F1

LD13F1

LD14F1

LD15F1

LD16F1

LD17F1

LC31F1

LC32F1

LC33F1

LC34F1

LC35F1

LC36F1

LC37F1

ORDERING INFORMATION

Description

90-264 VAC, Rectangular Bezel

90-264 VAC, Rectangular 2 holes Bezel

90-264 VAC, Round Bezel

90-264 VAC, Round 3 holes Bezel

90-264 VAC, Square Mount Bezel

10-80 VDC, Rectangular Bezel

10-80 VDC, Rectangular 2 holes Bezel

10-80 VDC, Round Bezel

10-80 VDC, Round 3 holes Bezel

10-80 VDC, Cup Mount Bezel

10-80 VDC, Stirrup Mount Bezel

10-80 VDC, Square Mount Bezel

4-30 VAC/DC, Rectangular Bezel

4-30 V AC/ DC, Rectangular 2 holes Bezel

4-30 V AC/ DC, Round Bezel

4-30 V AC/ DC, Round 3 holes Bezel

4-30 V AC/ DC, Cup Mount Bezel

4-30 V AC/ DC, Stirrup Mount Bezel

4-30 V AC/ DC, Square Mount Bezel

VIEWS OF DIFFERENT BEZELS

AC/DC Model HM36

4-30 VAC / DC, 50/60 Hz

50/60 Hz

Not applicable to AC and 48V for DC Application

1 VA

SAE & NEMA 4X (Equivalent to IP65)

Rectangular Bezel Rectangular 2 holes Bezel

Round Bezel

38

Cup Mount Bezel Stirrup Mount Bezel

Round 3 holes Bezel

Hour Meter Series HM36

MOUNTING DIMENSION (mm)

Square Mount Bezel (45 x 45 Panel Cutout)

= 45.00 =

R

1.

50

(4X

)

Round Bezel & Round 3 holes Bezel

Ø 64.26

Ø 50.80

Ø 3.80 (3X)

(3 equispaced hole)

CONNECTION DIAGRAM

For : DC Series

+

POWER

SUPPLY

+

GROUND

-

+

POWER

SUPPLY

IGNITION SWITCH

+

HOUR

METER

GROUND

-

PRESSURE SWITCH

HOUR

METER

L1

L2

L3

N

L

N

L

N

For : AC Series

Single phase, 2 wire, 120/240 V system:

Connect power wire to one terminal and neutral wire to opposite terminal.

Single phase, 3 wire, 120/240 V system:

Connect any one power wire to one terminal and neutral wire to opposite terminal.

Three phase, 4 wire, 120/240 V system:

Connect any one power wire to one terminal and neutral wire to opposite terminal.

Rectangular Bezel

0.06 R MAX(1.50)

1.450 (36.80)

Caution

Tighten terminals with flat head screwdriver with tip size 4.3 x 0.6 mm.

0.150 DIA(3.80)

1.750 (44.50)

Max. Panel Thickness :

0.029 (0.76) to 0.629 (16.00)

39

Hour Meter Series HM48

• Synchronous motor based

• Compact

• 7 digits (with 2 decimal)

• Maintenance free

• Flush / Base mounting

• International design

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Drive

Power Consumption (Max.)

Register

Read out

Least count

Accuracy

Vibration

Degree of Protection

Weight (unpacked)

Storage Temperature

Mounting

K54SF1

240V AC, 50Hz

-20% to +10%

(of )

Synchronous Motor

~ 1VA

7 Digital (2 Decimal)

99999.99

1/100 h

Directly proportional to supply frequency

10 to 2000 Hz with 0.5 g

IP20

70 g

-20°C to +55°C

Flush / Base

ORDERING INFORMATION

K 5 S 1

Voltage

1 24VAC 50Hz

3 110VAC 50Hz

4 240VAC 50Hz

Mounting

B Base Mounting

F Flush Mounting

WIRING DIAGRAM

EQUIP

OR

M/C

HM48

MOUNTING DIMENSION (mm)

HM48

FLUSH MOUNTING

40

48

50

33 48

BASE MOUNTING

M3 Tapping for mounting

43

ø3.2

ø4.2

48

39

23.5

40

Digital Hour Meters

• 6-digit LCD

• In-built nonvolatile memory (EEPROM) offering exceptional reliability

• Wide range of supply voltage

• Remote reset

• Available in 3 different shaped Bezels

• Low Power Consumption (Max.)

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Range

Display

Resolution

Accuracy

Memory Retention

Operating Temperature

Storage Temperature

Humidity

Degree of Protection

Enclosure

Terminals

Panel cut outs

Mounting

Certification

Z71FBX

ZJ1FBX

85-265 VAC

50/60 Hz

0.8 VA

99999.9 h

6-digit LCD 5mm Height

1/10 h

± 0.02%

100 Years

-10 ° C to +50° C

-20 ° C to +65° C

12-48 VAC/DC

50/60 Hz

0.4 W

95% (Rh)

IP54 (for front side only)

UL94V0

1, 2: Input Supply, 3: Enable 4: Reset

Round Bezel, 24 x 48 Bezel, Screw Mount Bezel

Flush / Panel Mounting

ZH1FBX

10-80 VDC

0.6 W

Weight (unpacked)

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

RoHS

Compliant

With Round Bezel- 35g, with 24 x 48 Bezel- 29 g, with Screw Mount Bezel- 31 g

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

ORDERING INFORMATION

Cat. No.

Z71FBX

ZJ1FBX

ZH1FBX

X

Description

85-265 VAC model

12-48 VAC/DC model

10-80 VDC model

A=Round Bezel, B=24x48 Bezel, C=Screw Mount Bezel

MOUNTING DIMENSION (mm)

Round bezel 24x48 bezel

Recommended Panel Cutout :

37.0 (+0.5)mm x 24.6 (+0.5)mm

Screw mount bezel

Recommended Panel Cutout :

37.0 (+0.5)mm x 24.6 (+0.5)mm

Recommended Panel Cutout :

45.5 (+0.5)mm x 23.0 (+0.5)mm

CONNECTION DIAGRAM

Supply ~/+

Supply ~/+ Supply ~/-

1 2

4 3

Reset Enable

Reset

Enable

TERMINAL DESCRIPTION

Pin 1: Supply (~ / +)

Pin 2: Supply (~ / -)

Pin 3: Enable

Pin 4: Reset

41

Impulse Counter Series CR 26

• 6-digit Compact and Robust Design

• Push-button quick reset

• High Accuracy and Reliability

• Requires no lubrication or maintenance

• Optional locking for reset button

• Ideal where space is limitation

• Three mounting options: Bail, Panel, Base

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Figure

Maximum Read Out

Operating Life

Speed

Pulse Width

Counting Method

Continuous Energizing

Reset

Weight (unpacked)

Operating Temperature

Humidity (Non Condensing)

Termination

Type of Mounting

Degree of Protection

Certification

SD21A-385

Note: Do not push reset button during change over.

RoHS Compliant

SD31A-385 SA41A-356 SA51A-356

12 VDC

+10% to -15%

(of )

24 VDC

2 Watts

6 Digit, White on Black, (4.0 mm) Height

9,99,999

Beyond 100 million counts

10 Hz Maximum (600 Counts / Minute)

115 VAC

3 Watts

230 VAC

50 ms minimum

One Pulse - One count (energizing - 1/2 count, de-energized - 1/2 count)

Permissible

Manual push button Reset (Reset button can be locked or sealed to avoid accidental reset)

142 g o o

- 5 C to + 50 C (Non-Freezing)

45 to 85% (Rh) o

22 AWG, 105 C wire leads, 254 mm long / 2 way Terminal Strip

Panel, Bail & Base

IP 30

Applications

Ideal for use in -

Machine tools, Business Machines, Test Instruments,

Amusement Instruments and Measuring devices

ORDERING INFORMATION

X X X X X

Product

X X X

S

N

Resettable Series CR-26

Non-Resettable Series CR-26

Model

A

D

For AC

For DC

356

385

Only for Rectangular - 2 Hole

Center Distance 35.6

Center Distance 38.5

Termination

A With 2 - way terminal strip

B With 22 AWG 254 mm long wire

Note: Terminal strip is not applicable for base mounting

Voltage

AC DC

Mounting

1 Rectangular - 2 Hole

2 Bail Mounting

3 Base Mounting

1

2

3 24 V 50/60 Hz

4 115 V 50/60 Hz

5 230 V 50/60 Hz

1 9 V

2 12 V

3 24 V

4 110 V

5 220 V

6 2.5 V

7 4 V

8 6 V

9 250 V

A 125 V

Note: Other voltages will be made available upon request.

42

Impulse Counter Series CR 26

MOUNTING DIMENSION (mm)

1.

Panel Mount

- 6 Figure

SXXXX-385

2.

Panel Mount

- 6 Figure

SXXXX-356

3.

Bail Mount -

6 Figure

4.

Base Mount -

6 Figure

60

5 6

56

78,7

56

68,1

10

10

10

Resettable Counter

SXXXA

A=With terminal strip

79

63,2

79

63,2

79

63,2

B=With 22 AWG

254 mm long wire

Panel cutout dimension

Ø 5(2X

)

Panel cutout

63,2

63,2

50,8

Ø 3,5

(2X)

Panel cutout

50,8

63,2

Panel cutout

50,8

71,9

63,2

68,10

Ø 3

,5(

4X

)

10

5.

Optional locking for reset button

Ø 1,2

To avoid the tampering with the reset button you can seal the counter as shown in the above figure

NON RESETTABLE COUNTER- NXXXA

A = Counter with Terminal Strip(not applicable for Base Mounting)

B = Counter with Wire (22 AWG 254 mm Long)

Note: For Non Resettable Counters, reset arm lever will not be present and all other details will be common with resettable counter.

43

Digital Counters

• 6-digit LCD

• In-built nonvolatile memory (EEPROM) offering exceptional reliability

• Wide range of supply voltage

• Remote reset

• Available in 3 different shaped Bezels

• Low Power Consumption (Max.)

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Counting frequency

Range

Display

Resolution

Reset

Memory Retention

Operating Temperature

Storage Temperature

Accuracy

Humidity (Non Condensing)

Degree of Protection

Enclosure

Terminals

Panel cut outs

Mounting

Certification

Z72FBX

ZJ2FBX

85-265 VAC

50/60 Hz

0.8 VA

10Hz

999999

Large 6-Digit display, easy to read

1 Count

Electrical

100 Years

- 10 ° C to +50° C

- 20 ° C to +65° C

± 1 Count

95% (Rh)

IP54

UL94V0

1.2: Input Supply, 3: Count 4: Reset

Round Bezel, 24 x 48 Bezel, Screw Mount Bezel

Flush/ Panel Mounting

12-48 VAC/DC

50/60 Hz

0.4 W

10Hz

ZH2FBX

10-80 VDC

0.6 W

30Hz

Weight (unpacked)

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips & Interruptions

RoHS Compliant

With Round Bezel- 35g, with 24 x 48 Bezel- 29 g, with Screw Mount Bezel- 31 g

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

ORDERING INFORMATION

Cat. No.

Description

Z72FBX

ZJ2FBX

ZH2FBX

X

85-265 VAC model

12-48V AC/DC model

10-80V DC model

A=Round Bezel, B=24x48 Bezel, C=Screw Mount Bezel

MOUNTING DIMENSION (mm)

Round bezel 24x48 bezel

Recommended Panel Cutout :

37.0 (+0.5)mm x 24.6 (+0.5)mm

Screw mount bezel

44

Recommended Panel Cutout :

37.0 (+0.5)mm x 24.6 (+0.5)mm

Recommended Panel Cutout :

45.5 (+0.5)mm x 23.0 (+0.5)mm

CONNECTION DIAGRAM

Supply ~/+

Supply ~/+ Supply ~/-

1 2

4 3

Reset Count

Reset

Count

TERMINAL DESCRIPTION

Pin 1: Supply (~ / +)

Pin 2: Supply (~ / -)

Pin 3: Enable

Pin 4: Reset

PROGRAMMABLE

LOGIC CONTROLLERS

Programmable Logic Controller Series

TM

GIC

www.gicindia.com

TM

Programmable Logic Controller

• Supports upto 48 I/Os

(32 digital inputs & 16 digital outputs)

• 250 lines of ladder programming

• 16 soft text messages,

Time Switches, Compare Counters,

Timers & Counters

• DST Feature Available

• Backlit LCD Screen for display & modification of

pre-selected parameters of functional blocks,

viewing I/O status and programming on the device

• PC software for programming, online & offline

simulation, documentation & printing

• Designed for use in automation for commercial &

Industrial sectors

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Max. Supply current

Power Consumption

Analog input range

Digital input range

Digital inputs

Analog inputs

Modbus Communication

Switching contacts

Electrical Life

Mechanical Life

DST

Timers

Counters

Analog Functions

Time Switches

Compare Counters

Soft Messages

Auxiliary Relays

I/O Extension (Max)

Power reserve (for clock only)

Lines for ladder program

Protection

External Protection

Storage temperature

Operating temperature

Humidity ( Non Condensing)

Mounting

Dimensions (W x H x D) (in mm)

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips

Mechanical Resistance :

Immunity to Vibrations

Certification

G7DDT9

Weight (unpacked) 248 g

MOUNTING DIMENSION (mm)

110-240 VAC, 50-60Hz

-20% to +10%

(of )

~ 36 mA

~ 5W

N A

(0-40 VAC) OFF, (80-265 VAC) ON

8

N A

Yes (RTU) (Slave)

4 SPST Relays, 8A @ 240 VAC / 5A @ 30 VDC (resistive)

10

5

10

7

Settable

16

16 (up / down, retentive selectable)

N A

16 (weekly / daily)

16

16 Priority Driven

32

Yes (3) o

C o

150h (lithium Battery) at -10 to +55 C

250

IP20

Fuse 250 mA

-20° C to +70°C

-10° C to +55°C

35% to 85 % (Rh)

Base / DIN rail

72 X 65 X 90

12-24 VDC

~ 360 mA

0 to 10 VDC

(0-4 VDC) OFF, (8-26.4 VDC) ON

6

2 (can be used digitally)

12

Fuse 500 mA

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Vibration Tests as per IEC 60068-2-6

RoHS Compliant

G8DDT9

232 g

CONNECTION DIAGRAM

72.0

17.0

65.0

EXT

SUPPLY

FUSE 1

MEMORY

CARD

GFDNN3

SERIAL

INTERFACE

CABLE

GFDNN2

INPUTS

L N

I1 I2 I3 I4 I5 I6 I7 I8 C1 C2

110 ~ 240 V AC

INPUT

8 X AC

PROGRAM

RUN

PARAMETERS

UTILITIES

DEL ALT

Z4

Z1

Z2

Z3

ESC OK

Q1 Q2

OUTPUTS

Q3

OUTPUT

4 x RELAY / 8A

Q4

L N

ADDITIONAL

INPUTS

1 2 3

INPUT

4 5 6 7 8

C1 C2

110 ~ 240 V AC

INPUT

8 X AC

1 2 3 4 5 6 7 8

1 2

OP

3 4

IP

SEL

A

B

C

OP1 OP2 OP3

ADDITIONAL

OUTPUTS

Extension Module

OUTPUT

4 x RELAY / 8A

OP4

UP TO

3 EXTENSION MODULES

46

Programmable Logic Controller

• Nx-Comm RS 485 Module

TM

Cat. No.

Parameters

Supply Voltage ( )

Input

Output

Number of Nodes

Isolation voltage

Baud Rate

Operating temperature

Storage temperature

Modbus Communication

LED Indicators

Certification

Weight (unpacked)

MOUNTING DIMENSION (mm)

G7XDTR4

110-240 VAC

TTL Level

RS- 485 protocol (two wires, D +, D -)

32 standard unit loads

2000 Vrms

300,600,1200,2400,4800,9600

-10 °C to + 55°C

-20 °C to + 70°C

Yes (RTU) (Slave)

Red LED's for Tx & Rx. Green LED for Supply.

RoHS Compliant

80 g

G8XDTR4

12-24 VDC

84 g

AC

SUPPLY

L

N

CONNECTION DIAGRAM

FUSE

L N

INPUTS

X

X

PROGRAM

RUN

PARAMETERS

UTILITIES

DEL ALT

TWO WIRE HALF

DUPLEX RS 485 BUS

SERIAL

INTERFACE

CABLE

Q1 Q2

OUTPUTS

Q3 Q4

TERMINAL TORQUE & CAPACITY

3.5 mm

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

2

1 x 0.2 - 3.3 mm Solid Wire / single wire ferrule twin ferrule

1 x 24 to 12 AWG

ORDERING INFORMATION

Cat. No.

G7DDT9

G8DDT9

G7DDT6E

G8DDT6E

GFDNN3M

GFDNN2S

GFDNN1

GNXNN1

G7XDTR4

G8XDTR4

Description

110-240 VAC, Genie Nx Base Module

12-24 VDC, Genie Nx Base Module

110-240 VAC, Genie Nx Extension Module

12-24 VDC, Genie Nx Extension Module

Memory Card

RS 232 Serial Communication Cable

USB Cable

Genie Nx Software supplied on CD-ROM compatible with Windows 98, 2000, XP & VISTA.

110-240 VAC, RS 485 Module

12-24 VDC, RS 485 Module

47

Programmable Logic Controller

TM

FEATURES

Programming:

Programming can be carried out independently using the keys on the Genie NX base module with the help of ladder diagram & on a PC, using "Genie NX Soft" software.

When using a PC, programming can be carried out either in Ladder Language.

LCD Backlighting:

Backlighting of the display will be there for minimum 15 seconds & by direct action of the keys on the base module or by using the "Device Utilities "option in Genie NX Soft application software.

Memory:

Genie NX has a back up memory, which allows programs to be transferred or copied into another Genie NX with the help of memory card. This feature enables quick copy of the programs without the use of a laptop or PC.

I/O Extensions:

User can connect maximum 3 Extension Modules to the Genie NX base module

& each Extension Module has 8 inputs and 4 outputs, so we can expand up to 48

I/O extensions if necessary via the Genie NX. Expansions are made in daisy chain fashion.

Communication Module:

A module for communication on the Modbus network is available, which is called "NX-Comm. "to facilitate communication of the logic relay over a 2 wire half duplex RS 485 link. Modules are powered by 110- 240 VAC or 12- 24 VDC supplies. The base module can be connected to this communication interface by means of the cable supplied and the communication takes place via the NX-

Comm. on the RS 485 link.

APPLICATIONS

For Industry:

• Printing and Packaging machines

• Ancillary equipments in textile, plastic.

• Material handling equipments, conveyor systems .

• Interlocking units in distributed control systems.

For Commercial / Building Sector:

• Automation of barriers

• Automation of compressors and pumps for air conditioning requirements

• Automation of lights

48

GIC

www.gicindia.com

SUPPLY MONITORING DEVICES

Supply Monitoring Series SM 301

Supply Monitoring Series SM 500

Supply Monitoring Series SM 501

Supply Monitoring Series SM 175

Frequency Monitoring Series PD 225

PTC Thermistor Relay Series PD 225

PTC Thermistor Relay & Phase Sequence Series PD 225

Supply Monitoring Series CMR - Current Control

Earth Leakage Relay Series CMR

50

Supply Monitoring Series SM 301

• Protects against Phase Loss,

Phase Reversal and Phase-Phase Unbalance

• No auxillary supply needed

• Voltage sensing principle

• Designed to meet Industrial and

Agricultural segment applications

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Mode of Operation

Trip Settings:

Phase - Phase Unbalance

Unbalance Hysteresis

Time Delays:

On Delay

Trip Time (Off Delay)

Setting Accuracy

Relay Output

Contact Rating

Electrical Life

Mechanical Life

Utilization Category

AC - 15

DC - 13

LED Indication

Operating Temperature

Storage Temperature

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

Certification

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

MA51BC

415 VAC

50-60 Hz

15 VA

Auto

MA51BK

10 - 18 VAC

10 - 18 VAC

2 Sec (fixed)

7 Sec (fixed)

± 10 % of full scale

1 C/O (SPDT)

5A (resistive) @ 250 VAC / 28 VDC

1X10

5

3X10

6

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

Red Relay ON (Healthy) o

C o

- 10 to + 50 C o

C o

- 20 to + 65 C

Flame Retardant UL 94V0

36 X 90 X 60

120 g

Base / DIN rail

IP20 for Terminals, IP 40 for Enclosure

RoHS Compliant

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

ORDERING INFORMATION

Cat. No.

MA51BC

MA51BK

Description

415 VAC, 50-60HZ with 65 VAC Asymmetry, 1 C/O

415 VAC, 50-60HZ with 40 VAC Asymmetry, 1 C/O

MOUNTING DIMENSION (mm)

60.0

CONNECTION DIAGRAM

TERMINAL TORQUE & CAPACITY

3.5 mm

AWG

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

2

1 x 0.2 - 3.3 mm Solid Wire / single wire ferrule twin ferrule

1 x 24 to 12

Supply Monitoring Series SM 500

• Protects against Phase Loss,

Phase Reversal and Phase-Phase Unbalance

• Can be configured for 3 phase 4 wire or 1 phase system

• Selectable Over/Under voltage trip level

• Adjustable time delay

• LED indications for power and fault conditions

• Voltage sensing principle

• 1 C/O or 2 C/O configuration

Cat. No.

Parameters

Supply Voltage ( )

MD71B9 MD71BH MD71BF

Frequency

Power Consumption (Max.)

Trip Levels: Under Voltage

Over Voltage

3 Phase 4 Wire, 240 VAC

1 Phase - 240 VAC

48 - 63 Hz

5 VA

55% - 95%

(of )

105% - 125%

(of )

Note: Voltage setting is with respect to neutral

Time Delays:

ON Delay

OFF Delay

Setting Accuracy

Relay Output

Contact Rating

Electrical Life

Mechanical Life

Utilization Category

AC - 15

DC - 13

LED Indication

Operating Temperature

Storage Temperature

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

Certification

0 to 15 m (Adjustable)

5 s (Fixed)

± 10 % of full scale

1 C/O (SPDT)

5A (Resistive) @ 250 VAC / 28 VDC

5

1 x 10

6

3 x 10

Flame Retardant UL 94V0

36 X 90 X 60

120 g

Base / DIN rail

0 to 15 s ( Adjustable)

5 s (Fixed)

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

Separate indications for Power ON, UV and OV

O O

-10 C To + 55 C

O O

-25 C To + 70 C

IP 20 for Terminals, IP 40 for Enclosure

5 s (Fixed)

0 to 15 s (Adjustable)

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

Note: 1) In the event of Phase sequence or phase loss, OFF delay is 100 ms

ORDERING INFORMATION

Cat. No.

MD71B9

MD71BH

MD71BF

Description

UV / OV with adjustable 0 to 15 m on delay time, 1C/O

UV / OV with adjustable 0 to 15 s on delay time, 1C/O

UV / OV with adjustable 0 to 15 s off delay time, 1C/O

MOUNTING DIMENSION (mm)

60.0

CONNECTION DIAGRAM

P

UV/OV

RELAY

P

UV/OV

RELAY

51

Supply Monitoring Series SM 500

52

Cat. No.

Parameters

Supply Voltage ( )

MG73B9 MG73BH MG73BF

Frequency

Power Consumption (Max.)

Trip Settings :

Under Voltage

Over Voltage

Phase - Phase Unbalance (Asy.)

Phase Reverse Detect

Hysteresis

3 Phase 4 Wire, 240 VAC

1 Phase, 240 VAC

48 - 63 Hz

5VA

55% - 95%

(of )

105% - 125% (of )

10%

Yes

7 V ± 2 V of trip voltage (factory set) Note: Voltage setting is with respect to neutral

Time Delays:

ON Delay

OFF Delay

Setting Accuracy

Relay Output

Contact Rating

Electrical Life

Mechanical Life

Utilization Category

Operating Temperature

Storage Temperature

AC - 15

DC - 13

LED Indication

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

Certification

0 to 15 m (Adjustable)

5 s (Fixed).

0 to 15 s (Adjustable)

5 s (Fixed)

± 10 % of full scale.

2 C/O (DPDT)

5A (Resistive) @ 250 VAC / 28 VDC

1X10

5

3X10

6

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A o

C o

C o

- 10 to +55 C o

- 25 to +70 C

5 s (Fixed)

0 to 15 s (Adjustable)

Separate indications for Power ON, UV, OV; ON: Phase Reverse, BLINK: Phase Unbalance (Asy.)

UL 94VO

36 X 90 X 60

120 g

Base / DIN rail

IP 20 for Terminals, IP 40 for Enclosure

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

Note: 1) In the event of Phase sequence or phase loss, OFF delay is 100 ms

ORDERING INFORMATION

Cat. No.

MG73B9

MG73BH

MG73BF

Description

3 Phase 4 Wire, UV/OV & single phasing Protection with adjustable 0 to 15 m On delay time , 2 C/O

3 Phase 4 Wire, UV/OV & single phasing Protection with adjustable 0 to 15 s On delay time, 2 C/O

3 Phase 4 Wire, UV/OV & single phasing Protection with adjustable 0 to 15 s Off delay time, 2 C/O

MOUNTING DIMENSION (mm)

CONNECTION DIAGRAM

P

P

Supply Monitoring Series SM 501

• Protects against Phase Loss,

Phase Reversal and Phase-Phase Unbalance

• Suitable for 3 phase 3 wire systems

• Selectable Over/Under voltage trip level

• Adjustable time delay

• Model for selectable Phase Asymmetry

• LED indications for power and fault conditions

• Voltage sensing principle

• 2 C/O configuration

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Trip Settings :

Under Voltage

Over Voltage

Phase Reverse Detect

Hysteresis

Phase - Phase Unbalance

Time Delays

ON Delay

OFF Delay

Setting Accuracy

MG53BH

415 VAC

48 - 63 Hz

10 VA

55% - 95%

(of )

105% - 125%

(of )

Yes

7 V ± 2V of trip voltage

10%

MG53BF MG53BI

94 V

Relay Output

Contact Rating

0.5 -15 s (adjustable)

5 s (fixed)

± 10 % of full scale

2 C/O (DPDT)

5A (Resistive) @ 250 VAC / 28 VDC

5

1 x 10

6

3 x 10 o o

- 10 C to +55 C o o

- 25 C to +70 C

Separate indications for Power ON: UV, OV, ON: Phase Reverse, BLINK: Phase Unbalance

UL 94V0

36 X 90 X 60

120 g

5 s (fixed)

0.5 - 15 s (adjustable)

± 10 % of full scale

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

5 s (fixed)

5 s (fixed)

± 10 % of full scale

Electrical Life

Mechanical Life

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

LED Indications

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

Certification

Base / DIN rail

IP 20 for Terminals, IP 40 for Enclosure

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

Note: 1) In the event of Phase sequence or phase loss, OFF delay is 100 ms

ORDERING INFORMATION

Cat. No.

MG53BH

MG53BF

MG53BI

MG53BO

MG63BH

MG63BF

Description

415 VAC, adjustable 0.5 - 15 s On & 5 s fixed Off Delay time, 2 C/O

415 VAC, adjustable 0.5 - 15 s Off & 5 s fixed On Delay time, 2 C/O

415 VAC, 94 volt fixed asymmetry, with 5 s fixed Off & On Delay time, 2 C/O

415 VAC, Under/Over Voltage, with fixed 3 m / Off Delay time, 2 C/O

220 VAC, adjustable 0.5 - 15 s On & 5 s fixed Off Delay time, 2 C/O

220 VAC, adjustable 0.5 - 15 s Off & 5 s fixed On Delay time, 2 C/O

MOUNTING DIMENSION (mm)

CONNECTION DIAGRAM

THREE PHASE APPLICATIONS

R Y B

15

L1 L2 L3

SM 501

25

16 18 26 28

TERMINAL TORQUE & CAPACITY

3.5 mm

AWG

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

2

1 x 0.2 - 3.3 mm Solid Wire / single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

53

Supply Monitoring Series SM 501

54

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Trip Settings :

Under Voltage

Phase Reverse Detect

Phase- Phase Unbalance

Time Delays

ON Delay

OFF Delay

Setting Accuracy

Electrical Life

Mechanical Life

Utilization Category

AC - 15

DC - 13

Relay Output

Contact Rating

Operating Temperature

Storage Temperature

LED Indications

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Degree of Protection

MB53BM

415 VAC

48 - 63 Hz

10 VA

80% of symmetrical, Hysteresis 7 V ± 2 V of input Voltage

Yes

5% - 17 % adjustable, Hysteresis 2%

0.5-15 s (adjustable)

0.5-15 s (adjustable)

± 10 % of full scale

1 x 10

5

6

3 x 10

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A

2 C/O (DPDT)

5A (Resistive) @ 250 VAC / 28 VDC o o

- 10 C to + 55 C o o

- 25 C to + 70 C

Indications for Power On, Symmetrical UV, Ph. Asymmetry, Reversal of phases.

UL 94V0

36 X 90 X 60

120 g

Base / DIN rail

IP 20 for Terminals, IP 40 for Enclosure

Certification

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-11

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

Note: 1) In the event of Phase sequence or phase loss, OFF delay is 100 ms

ORDERING INFORMATION

Cat. No.

MB53BM

Description

415 VAC, adjustable Asymmetry 5% - 17% , 2 C/O

MOUNTING DIMENSION (mm)

CONNECTION DIAGRAM

THREE PHASE APPLICATIONS

R Y B

15

L1 L2 L3

SM 501

16 18 26

25

28

TERMINAL TORQUE & CAPACITY

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

3.5 mm

AWG single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

Supply Monitoring Series SM 501

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Isolation

Mode of Operation

Trip Settings:

Phase - Phase Unbalance

Unbalance Hysteresis

Time Delays:

ON Delay

Trip Time (OFF Delay)

Setting Accuracy

Relay Output

Contact Rating

Electrical Life

Mechanical Life

MC21B5

415 VAC

48-63 Hz

15 VA

2.5KV (supply to relay contacts)

Auto

10 - 18 VAC

500 ms

500 ms

LED Indication

Operating Temperature

Storage Temperature

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

2 C/O (DPDT)

5A (resistive) @ 250 VAC / 24 VDC

1X10

5

3X10

6

Red LED ON Healthy, Red LED Flashing Wrong Connection/Sequence Fault

Red LED OFF Phase loss o

C o

- 10 to +50 C o

C o

- 25 to +70 C

Flame Retardant UL 94V0

36 X 90 X 60

120 g

Mounting

Degree of Protection

Certification

Base / DIN rail

IP 20 for Terminals, IP 40 for Enclosure

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class B

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

Note: 1) In the event of Phase sequence or phase loss, OFF delay is 100 ms

ORDERING INFORMATION

Cat. No.

Description

MC21B5

415VAC, 48-62HZ Phase fail / Phase Sequence 2 C/O

MOUNTING DIMENSION (mm)

60.0

CONNECTION DIAGRAM

25

MC21B5

26 28

TERMINAL TORQUE & CAPACITY

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

3.5 mm

AWG single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

55

Supply Monitoring Series SM 175

• Compact 17.5 mm wide

• Multi-voltage from 3 x 208 to 3 x 480 V

• Controls correct sequence of three phases & own supply voltage

• LED indication for all faults & for change in

settings during run time for better security

• 1 C/O configuration

• Selectable Under voltage / Over voltage / Asymmetry levels

• Adjustable time delay

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Settable Nominal Voltage (Un)

Trip Levels :

Under Voltage

Over Voltage

Asymmetry

Setting Accuracy

Time Delay

Setting Accuracy:

+/- 10% of Full Scale

ON Delay

OFF Delay

Relay Output

Contact Rating

Mechanical Life

Electrical Life

Utilization Category

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

AC - 15

DC - 13

(R)

Healthy

Relay

Phase Reverse

Asymmetry

OV

LED

Indications

UV

AS

All

LEDs

Degree of Protection

OFF

Flashing

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

MK21D5 MC21D5

3 Phase 3 Wire, 208 - 480 VAC, 45 - 65 Hz

-12% to + 10%

3 VA

(of )

N A

N A

N A

N A

+/- 5% of full scale

30% Fixed

~ 500 ms

5% to 15%

5 s (Fixed)

208 - 220 - 380 - 400 - 415 - 440 - 480 VAC

-2% to -20% (Un)

+2% to +20% (Un)

N A

5 s (Fixed)

-5% to -25% (Un)

+5% to +25% (Un)

10% Fixed

0.5 to 100 s

~ 100 ms

0.5 to 15 s 0.5 to 15 s

In the event of phase sequence or phase loss fault, OFF delay is ~100ms

5 s (Fixed)

1 C/O (SPDT)

5A (Resistive) @ 250 VAC / 30 VDC

6

3 x 10

5

1 x 10

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A o o

- 15 C to +60 C o o

- 20 C to +70 C

Max. 95%

Relay LED Continuous ON (Red Colour)

Relay LED Flashing (Red Colour)

N. A.

N. A.

N. A.

N. A.

Relay LED Off (Red Colour)

Phase Fail

N. A.

IP 20 for Terminal, IP 30 for Enclosure

18 X 90 X 59

70 g

Base / DIN rail

Power LED Continuous ON (Green Colour)

Power LED Flashing (Green Colour)

N A

OV - Red Colour LED ON

UV - Red Colour LED ON

AS-Red Colour LED ON

/ Un Pot changed in running conditions

RoHS Compliant

MA21DN MD21DF MG21DH

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

ORDERING INFORMATION

Cat. No.

MC21D5

MK21D5

MA21DN

MD21DF

MG21DH

MG21DF

Description

Phase Sequence, Asymmetry & Phase Loss Monitoring, 1 C/O

Phase Sequence, 1 C/O

Phase Sequence & Asymmetry Monitoring, 1 C/O

Phase Sequence, Under Voltage & Over Voltage Monitoring, 1 C/O

Phase Sequence, Asymmetry & Voltage Monitoring with Fixed OFF Delay (5 s), 1 C/O

Phase Sequence, Asymmetry & Voltage Monitoring with Fixed ON Delay (5 s), 1 C/O

56

Supply Monitoring Series SM 175

MOUNTING DIMENSION (mm)

17.5 (+0.5, -0.0)

CONNECTION DIAGRAM

TERMINAL TORQUE & CAPACITY

57

Frequency Monitoring Series PD 225

• Operable in various auxiliary supply voltage conditions &

frequency range by selecting proper model

• Models for Over Frequency and

Under/Over Frequency Monitoring

• Monitors frequency of three signals - Sine, Square & Triangular

• Model for Frequency Limit Control: 5 Hz to 135 Hz

• Wide Signal Input Voltage: 15 to 500 VAC

• Adjustable Relay status in healthy or

unhealthy condition using DIP switch "ET"

(Energize to Trip) or "DT" (De-energize to trip.)

• Ease of Frequency setting with

simple Addition & Subtraction

• LED indications for healthy,

unhealthy & no signal conditions

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Signal Type

Signal Input Voltage Range

Overall Frequency Range

Frequency Range Selection

Trip Level

Trip Levels

For Signal

Frequency

(%)

Over Frequency

Under Frequency

Reset Hysteresis

Setting Accuracy

Repeat Accuracy

Response

Time

ON Delay

OFF Delay

Reset Time

Relay Ouput

Contact Rating

Mechanical Life

Electrical Life

Contact Material

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED Indications for Relay

LED Indications for UF & OF

Degree of Protection

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

MI81BJ MI91BL

110-240 VAC, 48-62 Hz

-15% to + 15%

(of )

3 VA

Sinusoidal, Square, Triangular

(15 to 500) V

( 5 to 135) Hz

A

0

B

0

Frequency Range

(5 to 15) Hz

1 0

(15 to 45) Hz

0 1

(45 to 135) Hz

1 1 N A

0.33 to 1 of Full Scale

N A

1.5 % of Full Scale selected

± 5%

± 0.02%

~ 500 ms

~ 500 ms

~ 150 ms

220-440 VAC, 48-62 Hz

(40 to 70) Hz

50 Hz

60 Hz

(+ 1 to + 10) Hz

(- 1 to - 10) Hz

500 ms - 5 s

1 C/O (SPDT)

6A (Resistive) @ 240 VAC / 28 VDC

6

3 x 10

5

1 x 10

Ag alloy

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A o o

- 15 C to + 60 C o o

- 20 C to + 80 C

95% (Rh)

Red LED Flashing if No Signal N. A.

Seperate Indications given for UF & OF Status

N. A.

IP 20 for Terminal, IP 40 for Enclosure

22.5 X 83 X 100.5

120 g

Base / DIN rail

RoHS Compliant

CISPR 14-1

IEC 61000-4-2

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-11

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

58

ORDERING INFORMATION

Cat. No.

MI81BJ

MI91BJ

MI81BL

MI91BL

Description

110-240 V AC, Over Frequency Monitoring Series PD 225 with

ON Delay of 500 ms (Fixed), & OFF Delay of 500 ms (Fixed), 1 C/O

220-440 V AC, Over Frequency Monitoring Series PD 225 with

ON Delay of 500 ms (Fixed), & OFF Delay of 500 ms (Fixed), 1 C/O

110-240 V AC, Under/Over Frequency Monitoring Series PD 225 with

ON Delay of 500 ms (Fixed) & OFF Delay of 500 ms to 5 Sec. (Selectable), 1 C/O

220-440 V AC, Under/Over Frequency Monitoring Series PD 225 with

ON Delay of 500 ms (Fixed) & OFF Delay of 500 ms to 5 Sec. (Selectable), 1 C/O

Note: UL Approval for Cat Nos. MI81BL & MI91BL only

Frequency Monitoring Series PD 225

MOUNTING DIMENSION (mm)

22.5

4.30

100.5

81.0

10.0

12.5

INSERT SCREW DRIVER TO RELEASE DIN RAIL CLIP

DIN - RAIL (35mm symmetrical)

CONNECTION DIAGRAM

Signal

15

Frequency

Monitoring

Series PD 225

16 18

59

60

PTC Thermistor Relay Series PD 225

• Monitors and Protects motors with Integrated PTC resistor sensors

• Protection against over heating for Heavy Duty Load, High Switching

Frequency, High operating temperature & Insufficient cooling conditions

• 24 VAC/DC & 110-240 VAC, 220-415 VAC Models with 2 C/O & 1 C/O respectively

• Reset Options: Manual, Automatic and Remote

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Trip Level

Reset Level

Sensor Short

Hysterisis

Sensor Open

Max. Cold resistance of Sensor Chain

Mode of Reset

Repeat Accuracy

Response

Time

Relay Output

Time Delay

Reset Time

Contact Rating

Mechanical Life

Electrical Life

Contact Material

Utilization Category

AC - 15

DC - 13

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

LED

Indications

Power

Supply

Healthy

Sensor Open

Relay ON

Relay

Sensor Short

All LEDs OFF

Degree of Protection

Dimension (W x H x D) (in mm)

Weight (unpacked)

Mounting

Certification

MJ81BK MJ91BK

110-240 VAC, 48-62 Hz

-20% to + 10%

(of )

220-440 VAC, 48-62 Hz

3 VA

3.6 ± 5%

1.6 ± 5%

< ±

< ±

> 10 ± 5 %

< 1.5

Manual Reset, Auto Reset, Remote Reset (Selectable)

+/- 1%

ON Delay: ~500 ms OFF Delay: ~100 ms

~ 150 ms

1 C/O (SPDT)

6A (Resistive) @ 250 VAC / 28 VDC

6

3 x 10

5

1 x 10

Ag alloy

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A o o

- 15 C to +60 C o o

- 25 C to +80 C

95% (Rh)

Green LED Continuous ON

Green LED Flashing

Red LED Continuous ON

Red LED Flashing

Power Supply Fail

IP 20 for Terminals, IP 40 for Enclosure

22.5 X 83 X 100.5

120 g

Base / DIN rail

MJA3BK

24 VAC/DC, 48-62 Hz

2 VA

< 400 msec.

2 C/O (DPDT)

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

CISPR 14-1 Ed. 5.0 (2005-11) Class A

IEC 61000-4-2

IEC 61000-4-4

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

ORDERING INFORMATION

Cat. No.

MJ81BK

MJ91BK

MJA3BK

MJ83BK

MJ93BK

Description

110-240 V AC, Thermistor Series PD 225, 1 C/O

220-440 V AC, Thermistor Series PD 225, 1 C/O

24 VAC/DC, Thermistor Series PD 225, 2 C/O

110-240 V AC, Thermistor Series PD 225, 2 C/O

220-440 V AC, Thermistor Series PD 225, 2 C/O

MOUNTING DIMENSION (mm)

4.30

100.50

78.26

CONNECTION DIAGRAM

+ -

MJ81BK/MJ91BK

MJA3BK

10.0

12.5

22.50

INSERT SCREW DRIVER TO RELEASE DIN RAIL CLIP

DIN - RAIL (35mm symmetrical)

PTC Thermistor Relay &

Phase Sequence Series PD 225

• Thermistor relay combined with

protection against Phase sequence fault

• LED indications for Healthy, Unhealthy, Sensor Open/Short and

Phase Sequence fault conditions

• Separate relays for PTC Thermistor and Phase Sequence fault

• Reset Options: Auto/Manual

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Power Consumption (Max.)

Relay Output

Contact Rating

Utilization Category

AC - 15

DC - 13

Contact Material

Mechanical Life

Electrical Life

Trip level

Reset Level

Sensor Short

Hysterisis

Sensor Open

Max. Cold resistance of sensor chain

Reset mode

Repeat Accuracy

Response Time Operate Time (OT)

Release Time (RT)

Reset Time

LED Indications

Mounting / Dimensions (W X H X D)

Weight (Unpacked)

Operating Temperature

Storage Temperature

Humidity (Non Condensing)

Degree of Protection

Certifications

MLB4BK MLC4BK

380-480 VAC (3 Phase - 3 Wire), 50 +/- 2 Hz

-20% to +10%

(of )

12 VA

2 NO

380-480 VAC (3 Phase - 3 Wire), 60 +/- 2 Hz

6A @ 240 VAC / 28 VDC

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2/0.22/0.1 A

Ag alloy

6

3 X 10

5

1 X 10

3.6 +/- 5 %

1.6 +/- 5 %

< 20 +/- 4

< 40 , +/- 4

> 10 k +/- 5%

<1.5

Auto/Manual

+/- 1%

~ 500 ms

~ 100 ms

~ 150 ms

LED indications for Healthy, Unhealthy, Sensor Open / Short Conditions, SPPR fault Condition

Base / DIN-rail / (36 X 90 X 60) (in mm)

120 g o o

-15 C to +60 C o o

-25 C to +80 C

95% (Rh)

IP 20 for Terminals, IP 40 for Enclosure

RoHS Compliant

EMI/ EMC

Radio Interference Suppression

ESD Immunity

Electrical Fast Transients

Surge Immunity

Voltage Dips & Interruptions

Isolation

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IEC 61000-4-11 Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)

Test voltage between input & output - IEC 60255-5, 2kV

ORDERING INFORMATION

Cat. No.

MLB4BK

MLC4BK

Description

380-480 VAC, 50 Hz, Thermistor + Phase Sequence series PD225, 2 NO

380-480 VAC, 60 Hz, Thermistor + Phase Sequence series PD225, 2 NO

MOUNTING DIMENSION (mm)

60.0

36.0

Ø4.

2

INSERT SCREW DRIVER

TO RELEASE CLIP

WITHDRAW CLIPS

FULLY WHEN

SURFACE MOUNTING

L3

L2

L1

CONNECTION DIAGRAM TERMINAL TORQUE & CAPACITY

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M 2.5

3.5 mm

AWG single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

15 25

K1

M

3~

6A @ 240 VAC / 28 VDC

18 28

61

62

Supply Monitoring Series CMR - Current Control

• Protection against Overload, Phase Loss,

Phase Reverse, and Phase Unbalance faults

• Wide range of sensing current : 1A-45A

• Models for 1 Phase and 3 Phase systems

• Auto/Manual Reset selection

• Fail-safe protection

• Inverse time model with underload,

locked rotor protection and selectable trip class

• Definite time model with underload and

selectable start and trip time

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Current Ranges

Trip Type

Thermal Memory

Tripping Class

17A122CB0 17B122AA0

220-415 VAC, -20% to +15%

50 / 60 Hz

10 VA

3 - 9 A

Inverse Time

Yes

10A, 10, 20, 30

Definite Time

-

-

Start Time

Delay Time

Underload Protection

Phase Imbalance Protection

Phase Loss Protection

Locked Rotor Protection

Phase Reverse Protection

Reset Mode

Test Function

LED Indication ON

OL

UL

REV/UNB

40% - 90% (Trip Time: < 5 s) 50% / (Trip Time: < 5 s)

50% unbalance (Trip Time: < 5 s)

70% of unbalance (Trip Time: < 3 s)

300% of the set value

(Trip Time: < 3 s after starting)

Yes / (0.2 s approx.)

Auto / Manual

Yes

Power ON

Overload

Underload

ON: Phase Reverse / BLINK: Phase Unbalance

1 NO (Fail Safe Protection)

5A @ 240VAC

± 5 % of full scale

Output Relay Contact

Contact Rating

Tolerance

Certification

RoHS Compliant

EMI/EMC

Radio Interference Suppression

Electrical Fast Transients

Surge

Test Voltage between Input &

Output

CISPR 14-1

IEC 61000-4-4

IEC 61000-4-5

IEC 60947-5-1

Ed. 5.0 (2005-11) Class A

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 3.0 (2003-11) 2 KV

Mechanical Life Expectancy

Electrical Life Expectancy

Operating Temperature

Storage Temperature

Mounting / Dimensions

Weight (unpacked)

6

1 x 10

5

1 x 10

- 10° C to + 60° C

- 25° C to + 70° C

Base Mounting / 101 x 34 x 76.9

210 g

Note: In case of Phase loss protection, all LED's remains off.

ORDERING INFORMATION

Cat. No.

3 Phase

17A122CB0

17A222CB0

17A322CB0

17B122AA0

17B222AA0

17B322AA0

1 Phase

17C112EB0

17C212EB0

17C312EB0

17D112DA0

17D212DA0

17D312DA0

Description

Inverse Time Current Monitoring, 3 - 9 A, 1 NO

Inverse Time Current Monitoring, 8 - 24 A, 1 NO

Inverse Time Current Monitoring, 15 - 45 A, 1 NO

Definite Time Current Monitoring, 3 - 9 A, 1 NO

Definite Time Current Monitoring, 8 - 24 A, 1 NO

Definite Time Current Monitoring, 15 - 45 A, 1 NO

MOUNTING DIMENSION (mm)

17C112EB0

110-240 VAC, -20% to +10%

50 / 60 Hz

5 VA

17D112DA0

Inverse Time

Yes

10A, 10, 20, 30 -

-

Definite Time

0.2 - 30 s

0.2 - 10 s

40% - 90% (Trip Time: < 5 s) 50% / (Trip Time: < 5 s)

-

-

300% of the set value

(Trip Time: < 3 s after starting)

-

CONNECTION DIAGRAM

L1 L2 L3 L1 L2 L3

78.00

101.00

6.80

Ø

4.

8

0

R

2

.40

(2 x)

R2 .

40(2x)

Ø 11.00 (2x)

CMR

Start Stop

White

MA

Control

Power

Control

Power

CMR

White

Start / Stop

89.20

20.50

38.00

Motor Motor

Earth Leakage Relay Series CMR

• Monitors, detects and protects

power systems from Leakage faults

• Wide auxiliary supply range:

110 - 240 VAC, 220 - 415 VAC

• Wide range of selectable Earth Leakage Current:

60 mA - 300 mA, 0.2A - 1.2A

• Configurable Earth Leakage Trip time: 100 ms - 5 s

• Easily configurable operating modes

• Test feature to check complete product functionality

• Manual / Remote reset feature

• LED indication for relay status, CT open,

earth leakage fault & test/reset switch short

Cat. No.

Parameters

Supply Voltage ( )

Frequency

Power Consumption (Max.)

Relay Output

Contact rating

Mechanical Life

Electrical Life

Utilization Category

AC - 15

DC - 13

LED Indications

ON Delay Time

Trip (OFF) Time

Sensitivity

Setting Accuracy

Accuracy

Repeat Accuracy

Storage Temperature

Operating Temperature

Humidity (Non Condensing)

Certification

17G544FF1 17G644FF1

Weight (unpacked)

Degree of Protection

EMI/ EMC

Radio Interference Suppression

ESD

Electrical Fast Transients

Surges

Voltage Dips, Interruptions

Isolation

RoHS Compliant

119 g

IP 20 for Terminals, IP 40 for Enclosure

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

IE C-610004-1 L l A l

V I to VII Class B,

Test Vtg. between input & output - IEC 60947- 5-1, 2 kV

ORDERING INFORMATION

Cat. No.

17G514FF1

17G614FF1

Description

110-240V AC, Current Range 60 mA - 300 mA, 1 C/O

110-240V AC, Current Range 0.2 A-1.2 A, 1 C/O

17G544FF1

17G644FF1

17H5NNHL3

17H5NNIL3

220-415V AC, Current Range 60 mA - 300 mA, 1 C/O

220-415V AC, Current Range 0.2 A-1.2 A, 1 C/O

CBCT (tape wound) , 35mm, 60 mA - 300 mA

CBCT (tape wound), 65 mm, 60 mA - 300 mA

17H5NNJL3

17H6NNHL3

17H6NNIL3

17H6NNJL3

CBCT (tape wound),

CBCT (tape wound),

Note: CBCT's of other sizes will be available as required.

100 mm, 60 mA - 300

CBCT (tape wound), 35mm, 0.2 A - 1.2 A

65 mm, 0.2 A - 1.2 A

CBCT (tape wound), 100 mm, 0.2 A - 1.2 A mA

MOUNTING DIMENSION (mm)

4.3

0

100.50

78.26

17G514FF1 17G614FF1

220-415 VAC, -20 to +10%

50/60Hz

10 VA

1C/O (SPDT)

5 A @ 240 VAC / 30 VDC

10

7

10

5

110-240 VAC, -20 to +10%

50/60Hz

5 VA

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2/0.22/0.1 A

Green LED - Power ON, Red LED 1 ON - Earth Leakage, Red LED 2 - a. Blink - Test Switch short, b. ON - CT Open

50 +/- 20 ms

100ms to 5s (Adjustable)

60 mA - 300 mA 0.2 A - 1.2 A 60 mA - 300 mA

-10% (85 ms to 100 ms trip time for 100 ms setting in NFSNL)

0.2 A - 1.2 A

+/- 1%

-20 °C to + 80°C

-15 °C to + 60°C

95% (Rh)

IE C-610004-11 Le ve s I, I & V ss ,

Le ve s II to V ss B,

10.0

12.5

22.50

INSERT SCREW DRIVER TO RELEASE DIN RAIL CLIP

DIN - RAIL (35mm symmetrical)

Note : UL Approval for Cat Nos. 17G514FF1 & 17G614FF1 only

63

Earth Leakage Relay Series CMR

64

CONNECTION DIAGRAM

E

N L1 L2 L3

N/L2 L /L1

V

AUX

C1

C2

B1

B2

* *

* *

* *

* *

15

16

18

C1

C2

B1

B2

Y1 Y2

L /

L1

N/

L2

* *

REMOTE TEST / RESET

FAIL- SAFE LATCH

L /L1 N/L2 L /L1 N/L2

L /L1 N/L2

MCCB

FAIL SAFE,

NON LATCH

15

16

18

MCCB

NON FAIL SAFE,

NON LATCH

15

16

18

CONTACTOR

FAIL SAFE, LATCH

15

16

18

TERMINAL TORQUE & CAPACITY

Torque 0.54 N.m (5 Lb. in)

Terminal Screw - M3

3.5 mm

AWG single wire ferrule

2

2 x 0.5 - 2.5 mm Insulated with twin ferrule

1 x 20 to 10

Earth Leakage Relay Series CMR

• Monitors, detects and protects power systems from earth leakage faults

• Wide range of selectable Earth Leakage Current: 30 mA - 30 A

• Configurable Earth Leakage Trip time: 0 - 10 s

• Wide auxiliary supply range: 110 - 240 VAC, 220 - 415 VAC

• Instantaneous trip for 5 times of set value of leakage current

• Test feature to check complete product functionality

• LED indication for relay status, CT open,

earth leakage fault & test/reset switch short

• Manual / Remote reset feature

• 1 C/O + 1 NO relay output

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Frequency

Power Consumption (Max.)

Overall Leakage Current ( I n)

LED

Indication

Power

EL / CT

Leakage Current / TST

Relay Output

Contact Rating

Contact Material

Electrical Life

Mechanical Life

Utilization Category

AC - 15

DC - 13

Reset

No. of Resets

Clear Auto Reset

Test / Reset

Trip Time ( t in sec)

Reset Enable

Reset Time

Threshold I n (A)

Type Class

Max. Crest Factor

Accuracy

Setting Accuracy

Repeat Accuracy

Storage Temperature

Operating Temperature

Humidity (Non Condensing)

Enclosure

Dimension (W x H x D) (in mm)

Weight (unpacked)

Degree of Protection

Mounting

Certification

17G715GF2 17G715KF2 17G745GF2 17G745KF2

110 - 240 VAC

-20 to +20%

50/60Hz

5 VA

30 mA to 30 A (In 10 steps)

220 - 415 VAC

10 VA

Green LED (ON)

Red LED (ON) Relay Trip / Red LED (Blinking) CT Open

By Bar Graph: 30% (Green), 45% (Green), 60% (Yellow), 75% (Red), Blink Test / Reset Switch is pressed

1C/O (SPDT) + 1 NO (SPST)

5 A (Resistive) @ 240 VAC / 30 VDC

Ag Alloy

5

1X10

7

1X10

Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/ 1.5 A

Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2/0.22/0.1 A

Manual Reset Auto Reset

4

After 1 hour of healthy condition or supply interruption

Manual Reset

Local & Remote (Non Potential free contacts, upto 10 m)

0.03 - 0.06 - 0.15 - 0.25 - 0.5 - 0.8 - 1 - 2.5 - 5 - 10

Below 50% on current threshold set by potentiometer & in presence of CBCT

< 1s

0.03 - 0.1 - 0.3 - 0.5 - 1 - 3 - 5 - 10 - 20 - 30

'A' True RMS measurement (As per IEC 60947-2 appendix M)

5 (for 30 mA to 30 A)

-20% (Including CBCT Accuracy)

+/- 2%

-20 °C to + 80°C

-15 °C to + 60°C

95% (Rh)

Flame Retardant UL94-V0

18 X 60 X 85

70 g

IP 20 for Terminals, IP 40 for Enclosure

Auto Reset

Base / DIN Rail

RoHS Compliant

EMI/ EMC

Harmonic Current Emissions

ESD

Radiated Susceptibility

Electrical Fast Transients

Surges

Conducted Susceptibility

Voltage Dips & Interruptions

Conducted Emission

Radiated Emission

Environmental

Cold Heat

Dry Heat

Vibration

Repetitive Shock

Non-repetitive shock

CBCT

Dimensions in mm without enclosure

ID X OD X H

No. of Turns

CBCT 1

CBCT 2

CBCT 3

IEC 61000-3-2

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-11

CISPR 14-1

CISPR 14-1

Ed. 3.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 3.0 (2006-02) Level III

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

Ed. 2,2 (2006-05) Level III

Ed. 2.0 (2004-03) Level I, II, III, IV & V Class A, Level VI Class B

Ed. 5.0 (2005-11) Class A

Ed. 5.0 (2005-11) Class A

IEC 60068-2-1 Ed. 6.0 (2007-03)

IEC 60068-2-2 Ed. 5.0 (2007-07)

IEC 60068-2-6 Ed. 7.0 (2007-12) 5g

IEC 60068-2-27 Ed. 4.0 (2008-02) 40g, 6ms

IEC 60068-2-27 Ed. 4.0 (2008-02) 30g, 15ms

1500

45 X 65 X 15

65 X 90 X 15

100 X 125 X 15

ORDERING INFORMATION

Cat. No.

17G715GF2

17G715KF2

17G745GF2

17G745KF2

Description

110-240V AC, Current Range 30 mA - 30 mA, 1 C/O + 1 NO, Manual Reset

110-240V AC, Current Range 30 mA - 30 mA, 1 C/O + 1 NO, Auto Reset

220-415V AC, Current Range 30 mA - 30 mA, 1 C/O + 1 NO, Manual Reset

220-415V AC, Current Range 30 mA - 30 mA, 1 C/O + 1 NO, Auto Reset

65

Earth Leakage Relay Series CMR

CONNECTION DIAGRAM

NON-FAIL SAFE MODE WITH UV TRIP COIL

MCCB with UV

Trip Coil

E

L1

L2

L3

N

L1 L2 B1 B2 Y1

NON-FAIL SAFE MODE WITH CONTACTOR

CONT-

ACTOR

E

L1

L2

L3

N

L1 L2 B1 B2 Y1

NON-FAIL SAFE MODE WITH SHUNT TRIP COIL

MCCB

with

Shunt

Trip Coil

E

L1

L2

L3

N

L1 L2 B1 B2 Y1

15 16 18 25 28 Y2 15 16 18 25 28 Y2

FAIL SAFE MODE WITH UV TRIP COIL

MCCB with UV

Trip Coil

E

L1

L2

L3

N

L1 L2 B1 B2 Y1

15 16 18 25 28 Y2

FAIL SAFE MODE WITH CONTACTOR

CONT-

ACTOR

E

L1

L2

L3

N

L1 L2 B1 B2 Y1

15 16 18 25 28 Y2

ALARM

TERMINAL TORQUE & CAPACITY

3.5 mm

0.54 N.m (5 Lb.in)

Terminal screw - M2.5

1 x 0.2...3.3 mm

Solid Wire / Single

Wire Ferrule

2 x 0.2...1 mm

Insulated Twin

Wire Ferrule

AWG 1 x 24 to 12

Use Cu Wire of 60/75°C only.

66

15 16 18 25 28 Y2

ALARM

MOUNTING DIMENSIONS

36.0

Base / Din Rail Mounting

17.0

65.0

TEMPERATURE CONTROLLERS

PID Temperature Controller Series PR 69

GIC

www.gicindia.com

PID Temperature Controller Series PR 69

• Universal Input

• Configurable output combination

• Field configurable: band, deviation,

sensor break & loop break alarms

• Single/Dual acting PID controllers with 5 control modes

• Auto-tuning PID with provision for soft- start

• 6 segment ramp & soak profile with power failure

resumption modes

• Rapid set point change feature

• RS 485 communication

• Bumpless auto-manual transfer

• IP 65 protection

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Operating Temperature

Temperature sensors / inputs

Measurement Range

Measurement Accuracy

Resolution

Configurable Set Points

Display

Keypad

SSR output

Linear DC Output

Linear DC Output Update rate

Linear DC Output type

Contact rating

151D12B 151A12B 151B12B 151C12B

110-230 VAC, 50-60 Hz

-20%/+10%

(of )

O

C

O

0 to + 50 C

J, K, E, S, B, R thermocouple, RTD( PT100-3 wire compensation), mV signals (0-50 mV, 0-60 mV,12-60 mV)

Sensor J: 0 to 700°C/32 to 1292°F, Sensor K: 0 to 1300°C/32 to 2372°F,

Sensor E: 0 to 600°C/32 to 1112°F, Sensor R: 0 to 1750°C/32 to 3182°F, Sensor S: 0 to 1750°C/32 to 3182°F,

Sensor B: 250 to 1820°C/482 to 3308°F, Sensor Pt100 3 wire: - 200 to 700°C/-328 to 1292°F

+/-0.5% of full scale of PT100, +/-1% of full scale for TC

0.1°C for RTD, J,K,E & 1° for S,B & 0.001°C for mV signals

2

Dual 7 segment with LED indications, 4-digit process value, 4 digit set value

4-Keys: 1 - Enter, 2-Up, 3 - Down, 4 - Exit / on field set point selection

NA

12 VDC, 24mA, short circuit protection

NA

0 - 10V or 4 - 20mA

(user selectable)

NA

One SPST relay 8A,

NA

NA

240VAC OR 5A, 28VDC

Two SPST relay 5A 240VAC or 28VDC

150 ms - 5 s Programmable

Retransmission -

PV, Control - Output Power.

One SPST relay 5A,

240 VAC/ 28 VDC,

One analog output

(0-10 V, 4-20 mA) & a SSR driving output

(12 VDC, 24 mA)

2 relays (SPST 5A each,

240V AC / 28V DC) and One analog output

(0-10 V, 4-20 mA)

Statutory Requirements:

Pollution Degree

Degree of Protection

Dimensions (W x H x D) (in mm)

Certification

2

IP65 (For Front Panel only)

48 x 48 x 91.5

RoHS Compliant

EMI/EMC

Radio interference suppressions

ESD

Fast transients

Surges

Weight (unpacked)

CISPR 14-1

IEC 61000-4-2

IEC 61000-4-4

IEC 61000-4-5

185g

MOUNTING DIMENSION (mm)

Ed. 5.0 (2005-11) Class A

Ed. 1.2 (2001-04) Level II

Ed. 2.0 (2004-07) Level IV

Ed. 2.0 (2005-11) Level IV

GRID RING

85.0

91.5

68

TERMINAL TORQUE & CAPACITY

3.5 mm

AWG

Torque 0.5 N.m (5 Lb. in)

Terminal Screw - M3

2

1 x 0.12 - 2 mm Solid Wire / single wire ferrule

2

2 x 0.2 - 1 mm Insulated with twin ferrule

1 x 24 to 12

42.0 C/C

45.0

PID Temperature Controller Series PR 69

Cat. No.

Parameters

Supply Voltage ( )

Supply Variation

Operating Temperature

Temperature sensors / inputs

Measurement Range

Measurement Accuracy

Resolution

Configurable Set Points

Display

Keypad

SSR output

Linear DC Output

Linear DC Output Update rate

Linear DC Output type

151D13B1 151A13B1 151B13B1 151C13B1

110-240 VAC, 50-60 Hz

-20%/+10%

(of )

O

C

O

0 to + 50 C

J, K, E, S, B, R thermocouple, RTD( PT100-3 wire compensation), mV signals (0-50 mV, 0-60 mV,12-60 mV)

Sensor J: 0 to 700°C/32 to 1292°F, Sensor K: 0 to 1300°C/32 to 2372°F,

Sensor E: 0 to 600°C/32 to 1112°F, Sensor R: 0 to 1750°C/32 to 3182°F, Sensor S: 0 to 1750°C/32 to 3182°F,

Sensor B: 250 to 1820°C/482 to 3308°F, Sensor Pt100 3 wire: - 200 to 700°C/-328 to 1292°F

+/-0.5% of full scale of PT100, +/-1% of full scale for TC

0.1°C for RTD, J,K,E & 1° for S,B & 0.001°C for mV signals

4

Dual 7 segment with LED indications, 4-digit process value, 4 digit set value

4-Keys; 1 - Enter, 2-Up, 3 - Down, 4 - Exit / on field set point selection

N. A.

12 VDC, 24mA, short circuit protection

N. A.

0 - 10V or 4 - 20mA

(user selectable)

N. A.

N. A.

N. A.

150 msec - 5 sec Programmable

Retransmission -

PV or SP, Control - Output Power.

Contact rating

One SPST relay 8A,

240VAC OR 5A, 28VDC

Two SPST relay 5A 240VAC or 28VDC

One SPST relay 5A,

240 VAC/ 28 VDC,

One analog output

(0-10 V, 4-20 mA) & a SSR driving output

(12 VDC, 24 mA)

2 relays (SPST 5A each,

240V AC / 28V DC) and One analog output

(0-10 V, 4-20 mA)

Transmission Speed / RS 485

Transmission Speed

Protocol

Statutory Requirements:

Pollution Degree

Degree of Protection

Dimensions (W x H x D) (in mm)

Certification

300 to 19200 BPS

Half Duplex

Modbus RTU

2

IP65 (For Front Panel only )

48 x 48 x 91.5

RoHS Compliant

EMI/EMC

ESD

Radio interference suppressions

Fast transients

Surges

Weight (unpacked)

IEC 61000-4-2 Level II

CISPR 14-1 Class A

IEC61000-4-4 Level IV

IEC61000-4-5 Level IV

185g

ORDERING INFORMATION

Description

Cat. No.

151A12B

Single Acting

PID Controller

2 Relays (SPST 8A & 5A, 240 VAC / 28 VDC), SSR driving output (12 VDC, 24mA)

151B12B

151C12B

151D12B

1 Relay (SPST 5A, 240 VAC / 28 VDC), Analog output (0-10V, 4-20mA), SSR driving output (12 VDC, 24mA)

2 Relays (SPST 5A each,240V AC/28V DC), Analog output (0-10V, 4-20mA)

3 Relays (SPST One 8A & Two 5A, 240V AC / 28V DC)

151A13B1*

151B13B1*

151C13B1*

151D13B1*

Dual Acting

PID Controller

2 Relays (SPST 8A & 5A, 240 VAC / 28 VDC), SSR driving Output (12 VDC, 24mA)

1 Relay (SPST 5A, 240 VAC / 28 VDC), Analog output (0-10V, 4-20mA), SSR driving Output (12V DC, 24mA)

2 Relays (SPST 5A each, 240 VAC/28V DC), Analog output (0-10V, 4-20mA)

3 Relays (SPST One 8A & Two 5A, 240 VAC / 28 VDC)

*Note: With RS485 Modbus Communication

69

70

PID Temperature Controller Series PR 69

CONNECTION DIAGRAM

151A12B 151C12B

151B12B 151D12B

151A13B1 151C13B1

151B13B1 151D13B1

NOTES

71

GIC

T-107, M.I.D.C., Bhosari, Pune 411026 (INDIA)

Tel: +91 20 30680018 / 30680019 Fax: +91 20 27122574

Email: [email protected] | www.gicindia.com

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF