DSP U n in t e r ru pt ib le Power System s True On-Line Double Conversion Technology 3 phase in / 3phase out 120 & 160kVA IGBT Rectifier High Input Power Factor ( PFi ≥ 0.99 ) Low Input Current Harmonic Distortion Level ( THDi ≤ 5% ) High Overall Efficiency ( up to 94% ) Wide Input Voltage Range Evolution and redundancy guaranteed by Parallel Systems T E R N A TI O • IN Cold Start Function Emergency Power Off Function Automatic Battery Test Event Log up to 128 records Overload & Short Circuit Protections Communication with computers and network systems with SNMP & MODBUS availability Expandable battery blocks Low installation and operating costs 26 Q U A L IT Y C E ISO 9001 IFICATION • Static and Manual Bypass AL RT N Intelligent Battery Charging System PYRAMID DSP SERIES SPECIFICATIONS MODEL Output power ( kva ) Nominal Active Power ( kW ) PDSP3120 PDSP3160 120 160 96 128 0.8 Power factor INPUT 3Ph+N+PE Number of phases 380V/400V/415V Nominal Voltage -25% +20% Voltage range (%100 load) ( Ph-N ) 50 or 60 Nominal Frequency ( Hz ) Frequency range for online operation ±5 % Input Current THD ≤5 % Input Power Factor 0.99 OUTPUT 3Ph+N+PE Number of phases 380V/400V/415V Voltage Static Voltage Regulation at %100 Linear Load ( online&battery mode ) Voltage THD at rated linear load ± 1% <3% 3:1 Crest factor 50 or 60 Frequency (Hz) 50 or 60 ± 0.2% Free Running Frequency (Hz) Overload 125% for 10 minutes 150% for 1 minute Efficiency up to 94% STATIC BYPASS LINE 3Ph+N+PE Number of phases 220V / 230V (Ph-N) ± 10% Voltage Range for Bypass Operation 47-53 ( Configurable ) Frequency Range for bypass operation (Hz) BATTERY Maintenance Free Type 60 ( 2*30 ) Battery Quantity (pcs ) Charge Voltage 2 x 405 VDC Min. Discharge Voltage Value 2 x 300 VDC Battery Protection Deep Discharge Protection with Auto Cut off Standard Battery Test COMMUNICATION Interface RS232 & Dry Contact Communication Ports ENVIRONMENTAL CONDITIONS Storage Temperature Range (°C ) Operating Temperature Range (°C ) -25 to +55 ( 15 to 40 recomended for longer battery life time ) 0 to 40 ( 20 to 25 recomended for longer battery life time ) 0-90% ( non-condensing ) Relative Humidity Range 1000 Maximum Altitude without derating (m) IP20 Protection Level 1900x780x890 Dimensions HXWxD (mm) Weight (kg) 375 425 OPTIONS Parallel kit, SNMP internal slot card or external adapter, split by-pass, remote monitoring panel, battery cabinet, Modbus 27
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement