GSALTWR Aluminum Scaffold Tower

GSALTWR Aluminum Scaffold Tower
GSALTWR
201108
Scaffold Tower Assembly & Operating Instructions
INCLUDED INSIDE:
CODE OF SAFE PRACTICES
FOR FRAME SCAFFOLDS,
SYSTEM SCAFFOLDS,
TUBE AND CLAMP
SCAFFOLDS & ROLLING
SCAFFOLDS
DEVELOPED FOR INDUSTRY
BY SCAFFOLD INDUSTRY
ASSOCIATION, INC.
1,000 Lb. Max Capacity
2.0mm Aluminum Tube
50.8 x 2mm Diameter Tube
READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.
This manual provides important information on proper operation and maintenance. Every effort has
been made to ensure the accuracy of this manual. We reserve the right to change this product at any
time without prior notice.
STOP! DO NOT RETURN THIS PRODUCT TO THE RETAILER.
Questions? Problems? CONTACT CUSTOMER SERVICE. If you experience a problem or need parts for
this product, visit our website http://www.buffalotools.com or call 1-888-287-6981, Monday-Friday,
8 AM - 4 PM Central Time. A copy of the sales receipt is required.
IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE, DO
NOT OPERATE THIS PRODUCT!
KEEP THIS MANUAL, SALES RECEIPT & APPLICABLE WARRANTY FOR FUTURE
REFERENCE.
WARNING: Improper erection, dismantling or use of Scaffold Tower may result in serious injury or death!
Erectors, dismantlers, and users of Scaffold Tower must read and fully understand these Safety Rules and
Instructions.
MAXIMUM LOAD CAPACITY: 1,000 lbs (Workers & Materials)
WARNING: DO NOT OVERLOAD SCAFFOLD! IT MAY RESULT IN SERIOUS INJURY!
Recommended Scaffolding Erection Procedure
Introduction
This Guide has been prepared by the Scaffolding, Shoring & Forming Institute to assist contractors, architects,
engineers, dealers, erectors, and users, etc. for the proper use of scaffolding equipment. Scaffolding Safety
Rules published by the Institute should be used in conjunction with this publication, as well as the instruction
for the use of scaffolding provided by the manufacturer. Safety precautions and requirements prescribed by
local, state, and federal agencies, including OSHA, must be followed at all times and persons working with
scaffolding systems should be equipped with requisite safety devices.
I.
Nomenclature
1. Accessories-Those items other than the frames and braces used to facilitate the construction of
scaffolding towers and structures.
2. Adjustment Screws-Device composed of a thread screw and on adjusting handle used for the vertical
adjustment of the scaffolding.
3. Base Plate- A device used to distribute the leg load.
4. Climbing Ladders-A separate ladder attached to the scaffolding structure or built into the scaffold frame.
5. Casters- Wheels of a suitable dimension and unit designed to attach to the base of a tower and
containing a brake to prevent the wheels from rotation.
6. Coupling Pin-Device used to align and connect lifts or tiers together vertically.
7. Cross-bracing- Systems of members connecting frames or panels of scaffolding other than an
adjustment screw.
8. Extension Device- Any device used to obtain vertical adjustment of scaffolding other than and
adjustment screw.
9. Factor of Safety- The ratio of ultimate load to the allowable load.
10. Frame or Panel-The principal prefabricated, welded structural unit.
11. Guardrail-A rail secured to uprights and erected along the exposed sided and ends of platforms.
12. Horizontal Diagonal Bracing- Diagonal braces running horizontally between frames of scaffolding.
13. Lifts or Tiers- The number of frames stacked one above the other in a direction.
14. Locking Device- A device used to secure the cross brace to the panel.
15. Putlog or Truss-A separate horizontal load carrying member.
16. Rolling Towers- A composite structure of frames, braces, platforms, guardrails, and accessories
supported by casters.
17. Safe Leg Load- That load which can safely be directly imposed on a horizontal member.
18. Safe Scaffold Frame Horizontal Member Load- That load which can safely be directly imposed on a
horizontal member.
19. Scaffolding Layout- A engineered drawing prepared prior to erection showing arrangement of
equipment for proper scaffolding use.
20. Side Basket- A cantilevered arm unit supported by the scaffolding frame.
21. Sill or Mud Sill*- A footing, usually wood, which distributes the vertical leg loads to the ground.
22. Ties- A tension compression member used to securely attach scaffold to a structure.
23. Toeboard- A barrier secured along the sides and ends of a platform to guard against the falling of
material.
24. Towers- A composite structure of frames, braces, and accessories.
25. Ultimate Load- The maximum load which may be placed on the scaffolding causing failure by buckling
of column members or yielding of some component.
*These terms can be used synonymously.
2
Scaffold Tower Assembly & Operating Instructions
Inspection of Scaffolding Equipment Prior to Erection
Three main areas of inspection are for corrosion, straightness of members and welds. This applies to all
components of a scaffolding system.
1. Corrosion- Heavily rusted or eroded scaffolding equipment is a telltale sign of abuse or neglect.
3. Straightness of Members- Mishandling, trucking and storing may cause damage to scaffolding
equipment. All scaffolding components should be straight and free from bends, kinks or dents.
3. Welds- Equipment should be checked before use for damage of welds and any piece of equipment
showing damaged welds or rewelding beyond the original factory welds should not be used. The factory
weld reference pertains to location and quality of welds.
While corrosion, straightness of members, and welds are of primary concern other component parts
should be checked.
4. Locking devices on frames and braces shall be in good working order, and if not, must be repaired or
replaced prior to use.
5. Coupling pins must effectively align the frame or panel legs.
6. Pivoted cross braces must have the center pivot securely in place.
7. Caster Brakes shall be in good working order and if not must be repaired or replaced prior to use.
Safe Bearing Loads For Soils
Considering that the allowable loads (bearing) on various soils and rock range from less that 1,000 p.s.f. to
more than 50,000 p.s.f. care should be exercised in determining the capacity of the soil for every scaffolding
job, realizing that weather conditions can turn an otherwise suitable ground condition into a hazardous
situation. As an example, dry clay with an allowable bearing capacity of 8,000 p.s.f. could become very plastic
after a rainfall and drop to less than 2,000 p.s.f.
Care should also be taken not to excessively disturb the soil. If fill is required in areas where scaffolding is
used, a qualified engineer should be consulted as to materials and compaction.
II.
Foundations
The purpose of a good foundation or mud sill is to distribute the scaffolding load over a suitable ground area.
The size of the footing or sill is determined be the total load carried over a particular ground area, and by the
nature of the soil supporting these sills.
The total load should be computed and the sills designed accordingly.
When scaffolding from earth fill, the areas should be leveled and the sills spaced in a pattern assuring
adequate stability for all scaffolding legs.
III.
Erection of Frames
The work of erecting the scaffolding should be under the supervision of a person with proper experience and
aptitude for securing a safe installation and who is familiar with all Local, State and Federal Regulations
concerning scaffolding as well as the SSFI Scaffolding Safety Rules.
It shall be the responsibility of the person supervising the erection of the scaffold to see that all components
and locking devices are in working order, and no damaged or deteriorated equipment is used in the setup.
Should any scaffolding become damaged after the equipment has been erected, Workman shall not be
allowed on the same until the damaged items have been repaired or replaced.
Scaffold Tower Assembly & Operating Instructions
3
Advance planning will help the erection of scaffolding to progress smoothly. The equipment should be
unloaded as close to the area of use as possible and should be arranged in the order it is to be used in the
setup. Adjustment screws should be set to the approximate final adjustment before setting up the scaffolding.
Check that all coupling pins are matched with the proper panels. Consult safety rules as recommended by the
Institute.
After erecting the first tier of scaffold frames, plumb and level (using instruments) all frames so that no matter
how high the final scaffolding setup, the additional frames will also be in correct alignment.
As erection proceeds, securely tie all scaffolding to the structure at the ends and at least every 30’ horizontally,
and at height intervals not to exceed * four (4) times the minimum base dimension. Freestanding scaffold
towers must be restrained from tipping by guying or other means. Scaffold frames must be fastened together at
coupling pins where there is a possibility of uplift.
CODE OF SAFE PRACTICES FOR FRAME SCAFFOLDS, SYSTEM SCAFFOLDS,
TUBE AND CLAMP SCAFFOLDS & ROLLING SCAFFOLDS
DEVELOPED FOR INDUSTRY BY SCAFFOLD INDUSTRY ASSOCIATION, INC.
It shall be the responsibility of all users to read and comply with the following common sense guidelines which
are designed to promote safety in the erecting, dismantling and use of Scaffolds. These guidelines do not
purport to be all-inclusive not to supplant or replace other additional safety and precautionary measures to
cover usual or unusual conditions. If these guidelines in any way conflict with any state, local, federal or other
government statute or regulation, said statute or regulation should supersede these guidelines and it shall be
the responsibility of each user to comply therewith.
I.
GENERAL GUIDELINES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
4
POST THESE SCAFFOLDING SAFETY GUIDELINES in a conspicuous place and be sure that
all persons who erect, dismantle or use scaffolding are aware of them.
FOLLOW ALL STATE, LOCAL, AND FEDERAL CODES, ORDINANCES AND REGULATIONS
pertaining to scaffolding.
SURVEY THE JOB SITE. A survey shall be made of the job site for hazards, such as untamped
earth fills, ditches, debris, high tension wires, unguarded openings, and other hazardous conditions
created by other trades. These conditions should be avoided as noted in the following sections.
INSPECT ALL EQUIPMENT BEFORE USING. Never use any equipment that is damaged or
defective in any way. Remove it from the job site.
SCAFFOLDS MUST BE ERECTED IN ACCORDANCE WITH DESIGN AND/OR
MANUFACTURERS’ RECOMMENDATIONS.
DO NOT ERECT, DISMANTLY OR ALTER A SCAFFOLD unless under the supervision of a
qualified person.
DO NOT ABUSE OR MISUSE THE SCAFFOLD EQUIPMENT.
ERECTED SCAFFOLDS SHOULD BE CONTINUALLY INSPECTED by users to be sure that
they are maintained in safe condition. Report any unsafe condition to your supervisor.
NEVER TAKE CHANCES! IF IN DOUBT REGARDING THE SAFETY OR USE OF THE
SCAFFOLD, CONSULT YOUR SCAFFOLD SUPPLIER.
NEVER USE EQUIPMENT FOR PURPOSES OR IN WAYS FOR WHICH IT WAS NOT
INTENDED.
DO NOT WORK ON SCAFFOLDS if your physical condition is such that you feel dizzy or
unsteady in any way.
Scaffold Tower Assembly & Operating Instructions
IV.
GUIDELINES FOR ERECTION AND USE OF SCAFFOLDS
A.
SCAFFOLD BASE MUST BE SET ON AN ADEQUATE SILL OR PAD to prevent slipping or
sinking and fixed thereto where required. Any part of a building structure used to support the scaffold
shall be capable of supporting the maximum intended load to be applied.
B.
USE ADJUSTING SCREWS or other approved methods instead of blocking to adjust to uneven
grade conditions.
C.
BRACING, LEVELING, & PLUMING OF FRAME SCAFFOLDS—
1.
Plumb and level all scaffolds as the erection proceeds. Do not force frames or braces to fit –
level the scaffold until proper fit can easily be made.
2.
Each frame or panel shall be braced by horizontal bracing, cross bracing, diagonal bracing or
any combination thereof for securing vertical members together laterally. All brace connections shall be
made secure, in accordance with the manufacturer’s recommended procedures.
D. BRACING, LEVELING, & PLUMING OF TUBE & CLAMP AND SYSTEM SCAFFOLDS –
1.
POST SHALL BE ERECTED PLUMB in all directions, with the first level of runners and bearers
positioned as close to the base as feasible. The distance between bearers and runners shall not exceed
manufacturer’s recommended procedures.
2.
PLUMB, LEVEL AND TIE all scaffolds as erection proceeds.
3.
FASTEN ALL COUPLERS AND/OR CONNNECTIONS securely before assemble of next level.
4.
VERTICAL AND/OR HORIZONTAL DIAGONAL BRACING MUST BE ISNTALLED according to
manufacturer’s recommendations.
E. TIE CONTINUOUS (RUNNING) SCAFFOLDS TO THE WALL OR STRUCTURE at each end and at least
every 30 feet of length when scaffold height exceeds the maximum allowable free standing dimension.
Begin ties or stabilizers when the scaffold height exceeds that dimension, and repeat at vertical intervals not
greater than 26 feet. The top anchor shall be placed no lower than four (4) times the base dimension
from the top of the completed scaffold. Anchors must prevent scaffold from tipping into or away from wall
or structure. Stabilize circular or irregular scaffolds in such a manner that completed scaffold is secure
and restrained from tipping.
When scaffolds are partially or fully enclosed or subjected to overturning loads, specific precautions shall be
taken to insure the frequency and accuracy of ties to the wall and structure. Due to increased loads
resulting from wind or overturning loads the scaffolding component to which ties are subjected shall be
checked for additional loads.
F. WHEN FREE STANDING SCAFFOLD TOWERS exceed four (4) times their minimum base dimension
vertically, they must be restrained from tipping. (CAL/OSHA and some government agencies require
stricter ratio of 3 to 1)
G. DO NOT ERECT SCAFFOLDS NEAR ELECTRICAL POWER LINES UNLESS PROPER
PRECAUTIONS ARE TAKEN. Consult the power service company for advice.
H. A MEANS OF ACCESS TO ALL PLATFORMS SHALL BE PROVIDED.
I.
DO NOT USE ladders or makeshift devices on top of scaffolds to increase the height.
J. PROVIDE GUARDRAILS AND MID-RAILS AT EACH WORKING PLATFORM LEVEL where open sides
and ends exist, and toeboards where required by code.
K. BRACKETS AND CANTILEVERED PLATFORMS –
Scaffold Tower Assembly & Operating Instructions
5
1. Brackets for SYSTEM SCAFFOLDS shall be installed and used in accordance with manufacturer’s
recommendations.
2. Brackets for FRAME SCAFFOLDS shall be seated correctly with side bracket parallel to the frames and
end brackets at 90 degrees to the frames. Brackets shall not be bent or twisted from normal position.
Brackets (except mobile brackets designed to carry materials) are to be used as work platforms only and
shall not be used for storage of material or equipment.
3. Cantilevered platforms shall be designed, installed and used in accordance with manufacturer’s
recommendations.
L. ALL SCAFFOLDING COMPONENTS shall be installed and used in accordance with the manufacturer’s
recommended procedure. Components shall not be altered in the field. Scaffold frames and their
components manufactured by different companies shall not be intermixed, unless the component parts
readily fit together and the resulting scaffold’s structural integrity is maintained by the user.
M. PLANKING –
1.
Working platforms shall cover scaffold bearer as completely as possible. Only scaffold grade
wood planking, or fabricated planking and decking meeting scaffold use requirements shall be used
2.
Check each plank prior to use to be sure plank is not warped, damaged, or otherwise unsafe.
3.
Planking shall have at least 12" overlap and extend 6" beyond center of support, or be cleated
or restrained at both ends to prevent sliding off supports.
4.
Solid sawn lumber, LVL (laminated veneer lumber) or fabricated scaffold planks and platforms
(unless cleated or restrained) shall extend over their end supports not less then 6" nor more than 18".
This overhang should not be used as a work platform.
N. FOR "PUTLOGS" AND "TRUSSES" THE FOLLOWING ADDITIONAL GUIDELINES APPLY:
1.
Do not cantilever or extend putlogs/trusses as side brackets without thorough consideration for
loads to be applied.
2.
Putlogs/trusses should be extended at least 6" beyond point of support.
3.
Place recommended bracing between putlogs/trusses when the span of putlog/truss is more
than 12 feet.
O. FOR ROLLING SCAFFOLDS THE FOLLOWING ADDITIONAL GUIDELINES APPLY:
1.
RIDING A ROLLING SCAFFOLD IS VERY HAZARDOUS. The Scaffold Industry Association
does not recommend nor encourage this practice. However, if you choose to do so, be sure to follow all
state, federal or other governmental guidelines.
2.
Casters with plain stems shall be attached to the panel or adjustments screw by pins or other
suitable means.
3.
No more than 12 inches of the screw jack shall extend between the bottom of the adjusting nut
and the top of the caster.
4.
Wheels or casters shall be provided with a locking means to prevent caster rotation and scaffold
movement and kept locked.
5.
Joints shall be restrained from separation.
6.
Use horizontal diagonal bracing near the bottom and at 20 foot intervals measured from the
rolling surface.
7.
Do not use brackets or other platform extensions without compensating the overturning effect.
8.
The platform height of a Rolling Scaffold must not exceed four (4) times the smallest base
dimension (CAL/OSHA and some Government agencies require a stricter ratio of 3 to 1).
9.
Cleat or secure all plank.
10.
Secure or remove all materials and equipment from platform before moving.
11.
Do not attempt to move a rolling scaffold without sufficient help – watch out for holes in floor and
overhead obstructions – stabilize against tipping.
6
Scaffold Tower Assembly & Operating Instructions
P. SAFE USE OF SCAFFOLD –
1.
2.
3.
4.
5.
6.
Prior to use, inspect scaffold to insure it has not been altered and is in safe working condition.
Erected scaffolds and platforms should be inspected continuously by those using them.
Exercise caution when entering or leaving a work platform.
Do not overload scaffold. Follow manufacturer’s safe working load recommendations.
Do not jump onto planks or platforms.
Do not use ladders or makeshift devices on top of working platforms to increase height or
provide access from above.
7. Climb in access areas only and USE BOTH HANDS
I. WHEN DISMANTLING SCAFFOLDING THE FOLLOWING ADDITIONAL GUIDELINES APPLY:
A. Check to assure scaffolding has not been structurally altered in a way which would make it
unsafe and, if it has, reconstruct where necessary before commencing with dismantling
procedures. This includes all scaffold ties.
B. Visually inspect plank prior to dismantling to be sure they are safe.
C. Consideration must be given as to the effect removal of a component will have on the rest of the
scaffold prior to that component’s removal.
D. Do not accumulate excess components or equipment on the level being dismantled.
E. Do not remove ties until scaffold above has been removed (dismantled).
F. Lower dismantled components in an orderly manner. Do not throw off of scaffold.
G. Dismantled equipment should be stockpiled in an orderly manner.
H. FOLLOW ERECTION PROCEDURES AND USE MANUALS.
These safety guidelines (Code of Safe Practice) set forth common sense procedures for safely erecting,
dismantling and using scaffolding equipment. However, equipment and scaffolding systems differ, and
accordingly, reference must always be made to the instructions and procedures of the supplier and/or
manufacturer of the equipment.
TYPICAL APPLICATIONS INCLUDE:
•
•
•
•
•
Painting
Acoustical/Ceilings
Drywall installation & taping
Window Cleaning & Treatment Installation
Sign Installation and Maintenance
•
•
•
•
•
Overhead Door Installation
Lighting and wire Maintenance & Electrical
General Building Maintenance
HVAC Installation
Shelving
DISMANTLING NOTES
The work of dismantling scaffolding should be under the supervision of an individual with proper experience
and aptitude. The following should be observed while dismantling:
1. It shall be the responsibility of the user to read and comply with the following common sense guidelines that
are designed to promote safety in the dismantling of scaffolding.
2. Check to see if scaffold has been structurally altered in any way that would make it unsafe; and, if so,
reconstruct where necessary before commencing with the dismantling procedures.
3. Dismantle scaffold from the top down. Begin by removing all accessories from that section being dismantled
at the time.
Scaffold Tower Assembly & Operating Instructions
7
4. On stacked scaffolds do not remove ties and braces until dismantling has reached the section to which they
are attached.
5. Always work within the inside of the scaffolding.
6. When moving up or down the scaffold do NOT climb on ties, braces or un-braced components. Climb over
the top of the frame. Do not swing around outside of the frame.
7. Be sure that area below is clear of individuals not involved in the dismantling and is secured against
unauthorized access.
8. Lower scaffold components in a safe manner as they are dismantled. Avoid dropping or throwing the
components as this could result in injury or damage to the equipment.
9. Use energy absorbing lanyards and full body harness when feasible
SCAFFOLDING SAFETY RULES
SERIOUS INJURY OR DEATH MAY RESULT FROM IMPROPER ERECTION OR USE of scaffolding
equipment. Erectors and users must be familiar with and follow safe practice and the Safety Rules contained
herein. These Safety Rules cover generalized situations only and should not be used to replace any other
additional safety and precautionary measures that may be necessary to cover the many usual or unusual
conditions encountered during installation or dismantling. The
Rules are not intended to conflict with, or supersede the requirements of OSHA or any other governmental
regulations, codes and ordinances; the user must refer to and comply with all such specific provisions of law.
A. FOLLOW SAFE PRACTICE OF THE SAFETY RULES AND COMPLY WITH OSHA and all other federal,
state and local regulations, codes and ordinances pertaining to scaffolding during any use of the equipment.
B. THE POTENTIALLY HAZARDOUS NATURE OF SCAFFOLDING ERECTION WORK makes it important
that all personnel assigned to this work be instructed in these Safety Rules, safe practices and procedures and
be under the supervision of an experienced and knowledgeable person. Assure that these Safety Rules are
posted and that all persons erecting and using the scaffold are aware of and follow them.
C. REPORT ANY UNSAFE CONDITIONS TO SUPERVISORS. Do not work or allow persons to work on
scaffolds when sick or suffering from dizziness, unsteadiness or other physical symptoms which could affect
their ability to work safely.
D. INSPECT ALL EQUIPMENT BEFORE USING. Never use any equipment which is damaged, defective or
deteriorated in any way.
E. INSPECT ERECTED SCAFFOLD FREQUENTLY and be sure that they are maintained in safe condition,
that scaffold connections have not become loose and that components have not been improperly released or
removed.
F. MAINTAIN ALL EQUIPMENT IN GOOD REPAIR. Never use corroded or excessively rusted equipment; the
strength of such equipment is not known.
G. CONSULT YOUR SCAFFOLDING SUPPLIER WHEN IN DOUBT. NEVER TAKE CHANCES.
H. ALWAYS READ THESE SAFETY RULES in conjunction with the safety packet.
8
Scaffold Tower Assembly & Operating Instructions
I. ALWAYS SUPPORT SCAFFOLDS FROM A SOUND, STABLE SURFACE and assure that it is adequate to
support the intended scaffold loads. Never support scaffolds on unstable, loose objects which could tip, break
or become dislodged.
J. LIFT AND LOWER COMPONENTS CAREFULLY AND SAFELY; use tag lines when appropriate to the
handling method. Never allow excessive quantities of components to be stockpiled on partially complete
scaffolds. Stock only sufficient components consistent with the progress of the work. Lower dismantled
components as soon as possible. Never drop components deliberately.
K. TIEING THE SCAFFOLD TO THE STRUCTURE IS OF GREAT IMPORTANCE to the stability and safety of
the scaffold. Assure that the structure to which the scaffold is tied or anchored is capable of safely supporting
all loads imposed by the scaffold.
L. FREE STANDING SCAFFOLDS other than wall scaffolds must be restrained from tipping by guying or other
means, recognizing that stability is essential to the safety of the scaffold.
M. INSTALL GUARDRAILS, MIDRAILS, AND TOEBOARDS at all openings, open sides and ends of every
work platform when recommended or required.
N. NEVER USE LADDERS OR MAKESHIFT DEVICES on top of scaffold to increase the height. Never place
plank on or stand on guardrails and mid-rails.
O. POWER LINES NEAR SCAFFOLDS ARE DANGEROUS. Use extreme caution and consult the power
service company to have the lines de-energized, insulated or otherwise rendered safe.
Never allow any installation or use of scaffolds until this is done.
P. WHEN ANY CANTILEVERS ARE USED, such as brackets, etc., proper care and precautions must be
taken to prevent tipping of the scaffold.
Q. FOR ROLLING SCAFFOLDS, FOLLOW THESE ADDITIONAL SAFETY RULES:
a. Never ride rolling scaffolds.
b. Remove all material and equipment from the scaffold before moving.
c. Lock caster brakes at all times the scaffold is not being moved.
d. Do not attempt to move rolling scaffolds without sufficient help and roll on level surfaces only. Watch out for
holes or floor obstructions and for overhead obstructions, including power lines, energized craneways, and
other hazards.
e. The maximum platform height of a rolling scaffold must not exceed four (4) times the narrowest dimension.
Check local state/OSHA Regulations for other height/base limitations such as 3:1 in CA, OH, OR, MT and ME;
3.5:1 in WA. Comply with these regulations by appropriately widening and /or lengthening the scaffold at the
lower levels so that the above proportions are not exceeded. If the base dimensions cannot be increased,
extreme care must be taken to secure the scaffold from tipping; it must be guyed, or tied to a solid structure
and maintained in a stabilized condition at all times so that it cannot tip over while supporting persons, while
being moved or while being erected or dismantled.
f. Apply pulling or pushing forces at the bottom frames and as close to the scaffold base as possible. Never
attempt to move scaffold from on top.
g. If rolling scaffolds are used outdoors, care must be taken to assure that they cannot become unstable due to
wind or other conditions.
DO NOT OVERLOAD SCAFFOLD. Refer to and do not exceed the scaffold load capacities.
Scaffold Tower Assembly & Operating Instructions
9
Assembly Diagram
#9 Yellow Hook Brace
#4 Guard Rail
#14 Toe Board
#12 Platform w/ Hatch
Frame #3
#13 Platform
#6 Ladder A
#11 Blue Hook Brace
(10 Pieces)
Frame #2
51 Inches Deep
Frame #1
#8 Supporting Tube
#5 Stabilizer
102 Inches
#7 Ladder B
#9 Yellow Hook Brace
#10 Black Hook Brace
69 Inches Wide
95 Inches Across
Parts List
1
2
3
4
5
6
7
10
Frame # 1
Frame # 2
Frame # 3
Guard Rail
Stabilizer
Ladder A
Ladder B
49.25 inch x 78.75 inch
49.25 inch x 63 inch
49.25 inch x 47.25 inch
49.25 inch x 39.37 inch
97.3 inch x 62 inch
18 inch x 116.33 inch
18 inch x 119.88 inch
2
2
2
2
4
1
1
Scaffold Tower Assembly & Operating Instructions
Parts Diagram
#9 Yellow
Hook Brace
Parts List
8
9
10
11
12
13
14
15
Supporting Tube
Yellow Hook Brace
Black Hook Brace
Blue Hook Brace
8 Ft Platform w/Hatch
8 Ft Platform Closed
Wooden Toe Board
Adjustable Caster Wheel
13.77 inch x 53 inch
98.25 inch
103 inch
103 inch
21.25 inch x 98.25 inch
21.25 inch x 98.25 inch
95 inch x 45.86 inch
6 inch
Scaffold Tower Assembly & Operating Instructions
1
6
1
10
1
1
1
4
#10 Black
Hook Brace
#11 Blue
Hook Brace
11
SCAFFOLDING ASSEMBLY INSTRUCTIONS
Scaffold Height: 20 ft tall with casters
Remove all pieces and match them with the Parts List
Assemble Frame #1 by attaching #9 Yellow Hook Braces and #10 Black Hook Brace.
(You can identify the Frames by size. Frame #1 height is taller than Frame #2. But Frame #2 is
taller than Frame #3.)
Install two #11 Blue Hook Braces
Install Caster Wheels
Install four Stabilizers for support
If you intend to build the scaffold second level, add Frame #2
Install four #11 Blue Hook Braces
If you intend to build the scaffold to the full 20 ft height, add Frame #3
Install four #11 Blue Hook Braces
Install two #4 Guard Rails
Install #12 and #13 Platform
Install #14 Toe Board
Install four pieces #9 Yellow Hook Braces
Build the two-piece ladder inside the frame by connecting the #6 Ladder to the top Guard Rail.
Then attach #7 Ladder to the bottom of #6 Ladder and add #8 Support Tube.
(The Ladder will NOT touch the ground when the Caster Wheels are attached.)
12
Scaffold Tower Assembly & Operating Instructions