Daikin | FBQ50BV1A | That`s the Daikin difference Superior technology

That`s the Daikin difference Superior technology
Ducted Air Conditioners
Superior
technology.
Ultimate
comfort.
That’s the Daikin difference
PCDAU0202J
You’ll feel the
difference with a Daikin
we specialise in comfort
Daikin are air conditioning specialists. Our focus is on bringing climate-controlled comfort
to places where people live, work, meet and relax.
As a world leader in air conditioning and the largest manufacturer of air conditioners in
Japan, Daikin can be trusted to control the temperature, airflow and air quality in a broad
range of environments. From homes to high rises, from hospitals to hotels, Daikin has an
air conditioning solution that provides superior comfort.
With operations around the globe, Daikin has invested more than 80 years and billions of
dollars in research and development in the fields of mechanics, electronics and chemistry to
produce air conditioning products that are energy efficient, quiet, simple to use and reliable.
Founded in 1969, Daikin Australia has installed air conditioners into countless homes
across Australia and New Zealand. Daikin systems can also be found in thousands of
commercial developments and community projects.
CONTENTS
Daikin Difference
2
Daikin i-text
3
Daikin Technology
Inverter Ducted models
Non-Inverter Ducted models
2
PRODUCT
4-5
6-11
12-14
Daikin Solutions
15
Controlled comfort
at your fingertips
17
INVERTER DUCTED MODELS
FDXS25CVMA
RXS25EVMA
FDXS35CVMA
RXS35EVMA
FDXS50CVMA
RXS50FVMA
FDXS60CVMA
RXS60FVMA
(Page 7)
FBQ50BV1A
RXS50FVMA
FBQ60BV1A
RXS60FVMA
FBQ71BV1A
RXS71FVMA
FDYP71DLV1R
RZP71DV1
(Page 9)
NON-INVERTER DUCTED MODELS
FDY71LV1R
RY71LUV1S
RY71LUY1
FDY100LV1R
RY100LUY1
RY100LUV1S
(Page 13)
FDY125LV1R
RY125LUY1
FDY160LV1R
RY160LUY1
FDY200LV1R
RY200KUY1
FDY250LV1R
RY250KUY1
(Page 14)
FDYQ100MV1R
RZQ100PV4A
FDYQ125MV1R
RZQ125PV4A
FDYQ160MV1R
RZQ160PV4A
(Page 10)
FDYQ180MV1R
RZQ7PY1
FDYQ200MV1R
RZQ8PY1
FDYQ250MV1R
RZYQ10PY1
(Page 11)
Dedicated to making a Difference
Like us, our Dealers are specialists and will devote time and
effort to ensure you choose the right air conditioner for your
individual needs.
This is critically important. Having an air conditioner that is too
small for the job means you will be short on comfort; buying a
model that is too large for your space means big energy bills;
your Daikin Dealer will recommend a size that is just right.
As well as great advice your Daikin Specialist will give you a great
price, covering the cost of the air conditioner and installation.
They will also show you how to operate the unit so that you
get maximum comfort from your investment.
Daikin i-text
Control your air conditioner from your mobile phone
when you’re out and about.
Be in control wherever you go. Come home to a
Keeping an eye on your air conditioner from a distance
perfectly comfortable temperature simply by using
Keep an eye on your Daikin’s settings while you’re out and
your mobile phone. i-text is the latest advance in
about. This is especially convenient if there is someone in your
Daikin technology that allows you to switch your
house who is unsure how to operate your Daikin or if you’ve
air conditioning “on” or “off”, select your ideal
forgotten whether you’ve left it on or off.
temperature or check current settings, all via text
message. For peace of mind it texts you back to
Arriving home to a comfortable temperature
confirm your instructions have been carried out.
Whether it’s summer or winter, you can always walk into your
Daikin i-text can be easily and
quickly installed to new and
most existing air conditioning
home and know the temperature will be just as you want it.
Send a text message from your mobile and your Daikin will
respond instantly.
systems by your Daikin
Specialist.
Instant notification if anything goes wrong*
In the unlikely event of a malfunction occurring while you’re out,
a message will be sent to your mobile displaying an error code.
This will allow you to have the problem diagnosed and rectified
much quicker.
*Subject to GSM coverage. Sim Card required.
3
Daikin’s Energy
Saving Comfort
A Daikin ducted system can provide total air conditioned comfort throughout your
new or existing home. The indoor unit is usually located in the ceiling or under the floor,
with flexible ductwork distributing conditioned air through vents located in chosen
areas throughout the house, and the compressor is installed outside the home.
Daikin ducted systems offer great flexibility allowing operation in two or more zones.
This means you can operate your air conditioning system only in the living area during
the day, and only in the bedrooms at night, saving you money on energy costs.
UP TO 16 SYSTEMS CONTROLLABLE
FROM ONE REMOTE CONTROLLER
RETURN AIR GRILLE WITH FILTER
REMOVES HOUSEHOLD DUST
DUCTING FROM INDOOR UNIT TO
THE ROOMS OF YOUR CHOICE
MICROPROCESSOR CONTROLLED
OPERATION AND MONITORING
FULLY PROGRAMMABLE
24 HOUR/7 DAY TIMER AVAILABLE
SMALL SIZE REFRIGERANT
PIPES ARE EASILY CONCEALED
ENERGY EFFICIENT UNIT COOLS
OR HEATS THE AIR QUIETLY AND IS
AVAILABLE FOR THE WHOLE HOUSE
OR ZONED AREA
COMPACT AND QUIET OUTDOOR UNIT
(Excludes FDXS models)
DAIKIN’S INVERTER DIFFERENCE
Daikin Inverter air conditioners are more powerful yet they are also more energy efficient
than conventional, non-inverter models. Conventional air conditioners operate at a fixed
speed, delivering a fixed amount of cooling and heating. While trying to maintain a set
temperature they operate on a ‘stop/start’ principle.
A Daikin Inverter has a more advanced technology that operates differently. It works like
the accelerator of a car, gently increasing or decreasing power. It reaches the desired
temperature quicker and steadily maintains it without wild fluctuations. That means
uninterrupted comfort and significant energy savings.
4
Inverter Technology
Awarded Energy Savings
RELUCTANCE DC MOTOR
Daikin Inverter air conditioners are extra efficient and use considerably less energy than noninverter, conventional units. Daikin’s advanced technology is incorporated into a number of
the Inverter Ducted’s components resulting in significantly lower energy costs.
Daikin received the Japanese Electric Science and Promotion Prize for its innovative design.
More powerful Neodymium magnets in the Reluctance DC Compressor help generate more
power using less energy. Outstanding energy savings are achieved, particularly when operating
NEODYMIUM
MAGNET
in the lower speed zone.
FERRITE
MAGNET
Energy Saving Design
Daikin’s advanced compressor designs have achieved further energy savings in both the
Swing Compressor (71 class) and the latest Scroll Compressor (100, 125, & 160 class).
SWING COMPRESSOR
The Swing Compressor eliminates friction and leakage of refrigerant while the
Daikin Scroll Compressor has been redesigned to provide even greater
efficiencies than conventional scroll compressors.
Optimum efficiency is achieved with Daikin’s Heat Divide Type Heat Exchanger
by widening the area of heat exchanging. The coil structure together with the
properties of the R410A refrigerant are improved and the heat transfer
efficiency enhanced.
Sound Efficient
QUICKER AND MORE EVEN TEMPERATURE
Daikin Inverter air conditioner
Conventional air conditioner
noise, and much greater energy efficiency.
Hybrid Aerofoil Fan. High-Flared Bell Mouth. Super Aero Grille.
A recently designed fan, with an improved air flow analysis technique
cooling
Inverter smoothes the motor rotation resulting in a definite reduction in
Larger
temperature
difference
Smaller
temperature
difference
Quicker
advances in technology making quiet operation possible. DC Sine-Wave
TEMPERATURE
The Daikin Inverter Outdoor Ducted units benefit from significant
TIME
developed by NASA, plus other advanced features, provides smoother
and quieter air flow while at the same time offering a greater reduction
in power consumption.
In Night Quiet mode, the speed of the outdoor fan and compressor can be
daikin’s inverter outdoor units
incorporate 148 japanese patented features
1. reluctance dc compressor
timer operated or automatically reduced when the unit deduces that it is
2. dc sine-wave inverter
night time. This provides neighbour-friendly operation at night.
3. heat divide type heat
exchanger
8
4. new super cooling circuit
5. dc fan motor
Advanced REFRIGERANT Technology
Daikin is the only air conditioning company in the world that manufactures
refrigerants. R410A refrigerant provides excellent stability, low toxicity and noncombustibility. As well as offering superior energy saving. The R22 refrigerant is
a long-running industry standard refrigerant.
6. compressor linked fan
control
7. hybrid aerofoil fan.
high-flared bell mouth.
super aero grille.
5
2
6
3
7
8. intelligent precise
temperature control
4
1
5
Inverter
Bulkhead models
The Daikin Inverter range of FDXS units is ideal for one room or area of your home. The low profile design of only 200mm,
offers flexibility in installation and location of the indoor unit as it requires a ceiling void or bulkhead height of only 240mm.
Furthermore, installation of this series of units leaves maximum floor and wall space for location of furniture, decoration and
fittings. It also allows selection of architecturally suitable air inlet and outlet grilles (field supplied) to complement the
décor of the room.
Features
• Compact design for flexibility in installation.
• Leaves maximum floor and wall space available for furniture, decorations and fittings.
• Inverter Powerful mode can be selected for quick cooling or heating.
• The Home Leave operation offers added comfort whilst saving energy.
•Indoor unit Quiet Mode is useful for times when low noise or gentler cooling/heating
operation is required.
•Automatic Fan Speed mode selects the appropriate fan speed to suit the thermostat
settings and prevailing room temperature.
• Outdoor Unit Quiet Mode for lower outdoor noise operation.
1
2
3
5
6
7
4
8
• Hot Start mode ensures that only warm air is circulated during the heating operation.
• Swing Compressor for efficient, quiet and durable compressor operation.
• Reluctance DC Compressor Motor for added efficiency and energy saving.
•Automatic Changeover mode allows automatic selection of cooling or heating modes
to suit the thermostat settings and prevailing room temperature.
• PAM Control reduces energy loss ensuring powerful yet efficient operation.
•Programme Dry mode gives priority to reducing the level of humidity in the room rather
than room temperature.
•Indoor unit on/off switch (located on the signal receiver) allows operation of the system
in instances when the remote control has been misplaced or the batteries
are exhausted.
• 24 hour on/off timer starts and stops the air conditioner within a 24 hour period.
•Night set mode through the use of the timer off circuit, the air conditioner gradually
2 Selects mode:
automatic, cooling,
heating, dry, fan-only
operation
3 Outdoor Unit Quiet
Operation
increases the preset cooling temperature and lowers the preset heating temperature, in
4 Cancels On/Off Timer
order to prevent a sudden change in room temperature when the unit switches off.
5 24-Hour On Timer
•Auto restart mode memorises the settings on the controller before a power outage and
restarts the unit in the same operating conditions when power is restored.
•Anti Corrosion treatment of the outdoor unit heat exchanger ensures greater
resistance to salt damage and atmospheric corrosion.
•Self Diagnostics allows fast and easy diagnostics by monitoring the operation of the
system and displaying a malfunction code in the unlikely event of a problem developing
with the system.
•Automatic defrosting is carried out to minimise the amount of frost on the outdoor
heat exchanger ensuring efficient and high heating performance in winter.
1 Select between 5 fan
speeds and Indoor Unit
Quiet Operation
6 24-Hour Off Timer and
Night Set Mode
7 Sets Timer
8 Displays Time
[ FDXS25/35CVMA] [ FDXS50/60CVMA] [ RxS25/35EVMA] [ RxS50/60FVMA]
Indoor Unit
Outdoor Unit
Rated Capacity
Capacity Range
Power Input (Rated)
C.O.P.
Air Flow Rate (Rated)
Indoor Sound Level (@1.5m)
ESP Settings
FDXs25CVMA
FDXS35CVMA
FDXS50CVMA
FDXS60CVMA
RXS25EVMA
RXS35EVMA
RXS50FVMA
RXS60FVMA
6.0
Cool (kW)
2.4
3.4
5.0
Heat (kW)
3.2
4.0
5.8
7.0
Cool (kW)
1.2-3.0
1.2-3.8
1.7-5.3
1.7-6.5
Heat (kW)
1.2-4.5
1.2-5.0
1.7-6.0
1.7-8.0
Cool (kW)
0.69
1.09
1.65
2.13
Heat (kW)
0.91
1.18
1.92
2.32
C/H
3.48/3.52
3.12/3.39
3.03/3.02
2.82/3.02
l/s
158
167
200
267
dBA
35
35
37
38
Pa
40
40
40
40
5 steps, quiet & automatic
Indoor Fan Speeds
Dimensions
(H x W x D)
Weight
Power Supply
Indoor (mm)
200 x 900 x 620
200 x 900 x 620
200 x 900 x 620
200 x 1100 x 620
Outdoor (mm)
550 x 765 x 285
550 x 765 x 285
735 x 825 x 300
735 x 825 x 300
Indoor (kg)
25
25
27
30
Outdoor (kg)
32
32
48
48
1 phase, 220-240V, 50Hz
Ø/V/HZ
Hermetically sealed swing type
Compressor Type
R410A
Refrigerant
Refrigerant Control
Refrigerant Pipe Size
Liq (mm)
Gas (mm)
Drain Pipe Size
Electronic
Electronic
Electronic
Electronic
6.4 (Flared)
6.4 (Flared)
6.4 (Flared)
6.4 (Flared)
9.5 (Flared)
9.5 (Flared)
12.7 (Flared)
12.7 (Flared)
VP20 (OD 26,ID 20)
VP20 (OD 26,ID 20)
VP20 (OD 26,ID 20)
VP20 (OD 26,ID 20)
Supply Air Conn.
mm
153 x 860 (Flange)
153 x 860 (Flange)
153 x 860 (Flange)
153 x 1060 (Flange)
Return Air Conn.
mm
160 x 800 (Flange)
160 x 800 (Flange)
160 x 800 (Flange)
160 x 1000 (Flange)
Max Actual Pipe Length
m
20
20
30
30
Max Level Difference
m
15
15
20
20
Pre Charged Length
m
10
10
10
10
Cool (°CDB)
10 to 46
10 to 46
-5 to 46
-5 to 46
Heat (°CWB)
-10 to 20
-10 to 20
-15 to 18
-15 to 18
Pressure dBA (C/H)
47/48
47/48
47/48
49/49
Outdoor (dBA)
63
63
62
63
Outdoor Operating Range
Outdoor Sound Level (H)
@ 1 Metre from front of unit
EPA Sound Power Level
Due to ongoing product development, specifications are subject to change without notice. NB refer to notes on page 14.
Inverter
Ducted models
Superior Comfort
The Daikin Inverter range of ducted units is ideal for multiple rooms or zoned applications. The Daikin Inverter has
increased power at start-up, so the desired temperature is reached quicker. You can also dramatically reduce the
humidity levels in a matter of minutes with the Program Dry setting. Daikin Inverter Ducted systems handle the
most extreme temperatures and can guarantee operation in temperatures from a freezing -10°C to a searing 46°C.
Daikin’s inverter technology provides the comfort of precise temperature control,
reduced energy consumption and quiet indoor and outdoor units.
FEATURES OF Daikin Inverter Ducted Systems
•Requires only single phase power supply which can lower installation costs
(Models FBQ50~71B, FDYP71DL,FDYQ100~160M).
• Inverter compressor control for enhanced comfort levels.
• High efficiency – for greater energy savings.
• Quiet yet powerful operation.
•Instant computerised self-diagnostic system, reducing diagnostic time in the
unlikely event of a breakdown.
•Options and accessories available to customize the system to
individual requirements.
• Hot start system ensures warm air on start up.
• Auto restart after power failure.
FEATURES OF Inverter Indoor Units
• High efficiency (Hi-X) heat exchanger coils that further add to energy savings.
• Built to exceed compliance with relevant AS/NZS standards.
•Utilise Daikin’s leading edge DIII Net electronic control system,
for more precise control.
• High strength galvanised steel casing.
• Design of indoor units allows installation in limited roof spaces.
• Can be dismantled for easier installation into confined roof spaces.
• Microprocessor-controlled operation and monitoring.
FEATURES OF Inverter Outdoor Units
• Quiet operation.
• Night Quiet Mode reduces sound levels even further.
• New Swing and Scroll compressors for higher efficiency.
• Intelligent defrost for high heat output at low winter outdoor temperatures.
• Guaranteed operation down to -10°C in heating and up to 46°C in cooling.
• Up to 150m of refrigerant piping allows flexibility of location (Models 71-250).
•PE coated heat exchangers for greater protection against corrosion.
• Reluctance DC compressor motor for high efficiency operation.
• Compressor linked fan control achieves highest possible efficiencies.
*
*Applies to 71 class unit with no obstacles
on the sides of the unit. Bigger capacity
units require 100mm.
8
[ FBQ50BV1A]
Soft starter is unnecessary,
making electrical
installation work
much simpler.
[ FBQ60/71BV1A ]
[ RXS50FVMA]
[ RXS71FVMA]
Indoor Unit
FBQ50BV1A
FBQ60BV1A
FBQ71BV1A
FDYP71DLV1R
Outdoor Unit
RXS50FVMA
RXS60FVMA
RXS71FVMA
RZP71DV1
7.1
Rated Capacity
Capacity Range
Power Input (Rated)
C.O.P.
Air Flow Rate (Rated)
Indoor Sound Level (@1.5m)
Cool (kW)
5.0
5.7
6.7
Heat (kW)
6.0
7.0
8.2
8.3
Cool (kW)
1.7-5.6
1.7-7.0
2.3-8.0
3.3-9.5
Heat (kW)
1.7-7.0
1.7-8.0
2.3-10.0
3.7-9.7
Cool (kW)
1.98
2.23
2.57
2.5
Heat (kW)
1.93
2.26
2.67
2.5
C/H
2.53/3.11
2.56/3.10
2.61/3.07
2.84/3.32
l/s
217
300
300
590
dBA
33
34
34
45
LO/STD/HI
LO/STD/HI
LO/STD/HI
STD/HI
ESP Settings
Indoor Fan Speeds
Dimensions
(H x W x D)
Weight
Power Supply
Hi/Lo/LL
Hi/Lo/LL
Hi/Lo/LL
Hi/Lo/LL
Indoor (mm)
300 x 700 x 800
300 x 1000 x 800
300 x 1000 x 800
360 x 1168 x 869
Outdoor (mm)
735 x 825 x 300
735 x 825 x 300
770 x 900 x 320
905 x 900 x 320
Indoor (kg)
34
41
41
48
Outdoor (kg)
48
48
71
71
Ø/V/HZ
1 phase, 220-240V, 50Hz
Compressor Type
Hermetically Sealed, Swing Type
Refrigerant
Swing Rotrary
R410A
Refrigerant Control
Electronic
Electronic
R407C
Electronic
Electronic
Liq (mm)
6.4 (Flared)
6.4 (Flared)
6.4 (Flared)
9.5 (Flared)
Gas (mm)
12.7 (Flared)
12.7 (Flared)
15.9 (Flared)
15.9 (Flared)
Supply Air Conn.
mm
245 x 460 (Flange)
215 x 760 (Flange)
215 x 750 (Flange)
245 x 752 (Flange)
Return Air Conn.
Refrigerant Pipe Size
Drain Pipe Size
VP25 (OD 32, ID 25)
OD 32, ID 25
mm
228 x 533 (Flange)
228 x 833 (Flange)
228 x 900 (Flange)
1 x 400 (Oval)
Max Actual Pipe Length
m
30
30
30
50
Max Level Difference
m
20
20
20
30
Pre Charged Length
m
10
10
10
30
Outdoor Operating Range
Outdoor Sound Level (H)
@ 1 Metre from front of unit
EPA Sound Power Level
Cool (°CDB)
-5 to 46
-5 to 46
-5 to 46
Heat (°CWB)
-15 to 18
-15 to 18
-10 to 15
Pressure dBA (C/H)
47/48
49/49
49/52
48/50
(dBA)
62
63
66
66
Due to ongoing product development, specifications are subject to change without notice. NB refer to notes on page 14.
9
Inverter Ducted models
[ FDYQ100/125/160MV1R]
Indoor Unit
Outdoor Unit
Rated Capacity
Capacity Range
Power Input (Rated)
C.O.P.
Air Flow Rate (Rated)
Indoor Sound Level (@1.5m)
Power Supply
FDYQ125MV1R
FDYQ160MV1R
RZQ100PV4A
RZQ125PV4A
RZQ160PV4A
15.5
Cool (kW)
9.8
12.5
12.5
14.9
18.0
Cool (kW)
5.0-11.2
6.0-14.0
6.4-15.5
Heat (kW)
5.9-12.5
6.4-16.0
6.8-18.0
Cool (kW)
3.09
4.17
5.74
Heat (kW)
3.60
4.47
5.66
C/H
3.17/3.47
3.00/3.33
2.70/3.18
l/s
815
925
1070
dBA
46
48
51
STD/HI
STD/HI
STD/HI
Hi/Lo/LL
Hi/Lo/LL
Indoor Fan Speeds
Weight
FDYQ100MV1R
Heat (kW)
ESP Settings
Dimensions
(H x W x D)
[ RZQ100/125/160PV4A]
Hi/Lo/LL
Indoor (mm)
360 x 1478 x 899
Outdoor (mm)
Indoor (kg)
1345 x 900 x 320
61
65
Outdoor (kg)
Ø/V/HZ
1 phase, 220-240V, 50Hz
Compressor Type
Hermetically Sealed Scroll Type
Refrigerant
R410A
Refrigerant Control
Electronic
Electronic
Liq (mm)
Refrigerant Pipe Size
Gas (mm)
mm
Return Air Conn.
mm
Max Actual Pipe Length
m
Max Level Difference
m
Outdoor Sound Level
@ 1 Metre from front of unit
EPA Sound Power Level
<20m Ø 15.9
20-90m Ø 19.1
90-150m Ø 22.2
15.9 (Flared)
ID 25mm OD 32mm
Supply Air Conn.
Outdoor Operating Range
Electronic
9.5 (Flared)
Drain Pipe Size
Pre Charged Length
66
125
m
1152 x 245 (Flange)
2 x 400 (Oval)
150
150
150
50 (40 if outdoor unit is below)
0
0
Cool (°CDB)
-5 to 46
Heat (°CWB)
-20 to 15.5
0
Pressure dBA (C/H)
50/52
51/53
53/55
dBA
68
-
-
Due to ongoing product development, specifications are subject to change without notice. NB refer to notes on page 14.
10
[ FDYQ180/200MV1R] [ FDYQ250MV1R] [ rzyq7/8/10py1]
Indoor Unit
Outdoor Unit
Rated Capacity
Capacity Range
Power Input (Rated)
C.O.P.
Air Flow Rate (Rated)
Indoor Sound Level (@1.5m)
Power Supply
FDYQ250MV1R
RZYQ7PY1
RZYQ8PY1
RZYQ10PY1
25.0
Cool (kW)
18.0
20.0
20.0
22.4
28.0
Cool (kW)
10.8-20.0
12.0-22.4
15.0-28.0
Heat (kW)
12.0-22.4
13.4-25.0
16.8-31.5
Cool (kW)
5.68
6.43
8.90
Heat (kW)
5.63
6.27
8.28
C/H
3.17/3.58
3.11/3.57
2.81/3.38
l/s
1180
1200
1400
dBA
51
51
51
STD/HI
STD/HI
STD/HI
Indoor Fan Speeds
Weight
FDYQ200MV1R
Heat (kW)
ESP Settings
Dimensions
(H x W x D)
FDYQ180MV1R
Indoor (mm)
Hi/Lo/LL
Hi/Lo/LL
Hi/Lo/LL
500 x 1210 x 910
500 x 1210 x 910
500 x 1410 x 910
Outdoor (mm)
1680 x 930 x 765
Indoor (kg)
77
79
98
Outdoor (kg)
205
205
249
Ø/V/HZ
3/415/50
3/415/50
3/415/50
Compressor Type
Hermetically Sealed Scroll Type
Refrigerant
R410A
Refrigerant Control
Refrigerant Pipe Size
Electronic
Electronic
Electronic
Liq (mm)
9.5 (Brazed)
9.5 (Brazed)
9.5 (Brazed)
Gas (mm)
19.1 (Brazed)
19.1 (Brazed)
22.2 (Brazed)
Drain Pipe Size
BSP 3/4 inch Internal Thread (OD 32.7mm)
Supply Air Conn.
mm
827 x 376 (Flange)
827 x 376 (Flange)
939 x 376 (Flange)
Return Air Conn.
mm
918 x 350 (Flange)
918 x 350 (Flange)
1118 x 350 (Flange)
Max Actual Pipe Length
m
150
150
150
Max Level Difference
m
Pre Charged Length
Outdoor Operating Range
Outdoor Sound Level (H)
@ 1 Metre from front of unit
m
50 (40 if outdoor unit is below)
0
Cool (°CDB)
Heat (°CWB)
Pressure dBA (C/H)
0
0
-5 to 43
-20 to 15.5
57/57
57/57
58/58
Due to ongoing product development, specifications are subject to change without notice. NB refer to notes on page 14.
11
Non-Inverter
Ducted Models
Comfort built-in
Built to exceed Australian standards, Daikin’s non-inverter systems are quiet, yet powerful.
Features of Daikin Non-Inverter
Ducted Systems
• Microprocessor controlled operation and monitoring.
•Instant computerised self diagnostic system, for reduced diagnostic time in the unlikely
event of a breakdown.
• Auto restart after power failure.
• Hot start system ensures warm air on start up.
• Options and accessories available to customise the system to individual requirements.
Features of Daikin Non-Inverter Indoor Units
• High efficiency Hi-X heat exchanger coils that enhance energy savings.
• Quiet yet powerful supply air fan.
• Built to exceed compliance with AS/NZS standards.
• Daikin’s leading edge DIII Net electronic system for more precise control.
• High strength galvanised steel casing.
• Design of indoor units allows installation in limited roof spaces.
• Can be dismantled for easier installation into confined roof spaces (FDY71-FDY160).
Features of Daikin Non-Inverter Outdoor Units
• Quiet scroll compressors.
• PE coated heat exchangers protect against corrosion.
• Intelligent defrost for high heat output at low winter outdoor temperatures.
• Long refrigerant pipe runs for flexibility of location of outdoor units.
•Guaranteed operation up to 46°CDB outdoor temperature in cooling
(Up to 50°C for RY200 and RY250 models.)
• Guaranteed operation down to -10CWB in heating.
Aerodynamic propellers with a
large wing surface are designed
to move large volumes of air with
minimal turbulence resulting in
quiet operation.
The curved ribs of the grille are
designed to cater for large volumes
of air whilst minimising turbulence.
12
[ FDY71LV1R ]
[ FDY100LV1R ]
[ ry71LUV1S ]
[ ry71LUY1 ]
INDOOR UNIT
FDY71LV1R
OUTDOOR UNIT
Rated Capacity
Power Input (Rated)
C.O.P.
Air Flow Rate (Rated)
Indoor Sound Level (@1.5m)
RY71LUV1S
Power Supply
RY71LUY1
RY100LUY1
RY100LUV1S
Cool (kW)
8.3
10.9
9.1
11.8
Cool (kW)
3.4
4.2
Heat (kW)
2.7
3.5
C/H
2.49/3.53
2.63/3.37
l/s
590
815
dBA
45
46
Std/Hi
Std/Hi
Indoor Fan Speeds
Weight
FDY100LV1R
Heat (kW)
ESP Settings
Dimensions
(H x W x D)
[ ry100LUY1 ]
[ ry100LUV1S ]
Hi/Lo/LL
Hi/Lo/LL
Indoor (mm)
360 x 1168 x 869
360 x 1478 x 899
Outdoor (mm)
770 x 900 x 320
1170 x 900 x 320
Indoor (kg)
48
59
Outdoor (kg)
73
72
86
89.4
Ø/V/HZ
1/240/50
3/415/50
3/415/50
1/240/50
Compressor Type
Scroll
Refrigerant
Refrigerant Control
Scroll
R22
R22
Electronic
Electronic
Liq (mm)
9.5 (Flared)
9.5 (Flared)
Gas (mm)
15.9 (Flared)
19.1(Flared)
Drain Pipe Size
mm
ID Ø 25mm x OD Ø 32mm
ID Ø 25mm x OD Ø 32mm
Supply Air Conn.
mm
245 x 752 (Flange)
245 x 1152 (Flange)
Return Air Conn.
mm
1 x 400 (Oval)
2 X 400 (Oval)
Max Actual Pipe Length
m
50
50
Max Level Difference
m
30
30
Pre Charged Length
m
30
30
Cool (°CDB)
-15 to 46
-5 to 46
Heat (°CWB)
-10 to 15
-10 to 15
Pressure dBA (C/H)
49/50
50/53
dBA
66
69
Refrigerant Pipe Size
Outdoor Operating Range
Outdoor Sound Level
@ 1 Metre from front of unit
EPA Sound Power Level
Due to ongoing product development, specifications are subject to change without notice. NB refer to notes on page 14.
13
Non-Inverter Ducted Models
[ ry125LUY1 ]
[ ry160LUY1 ]
[ ry200/250KUY1 ]
Indoor Unit
FDY125LV1R
FDY160LV1R
FDY200LV1R
FDY250LV1R
Outdoor Unit
RY125LUY1
RY160LUY1
RY200KUY1
RY250KUY1
Notes
•Rated capacity is measured
in accordance with AS/NZS
3823.1.2.
Rated Capacity
Power Input (Rated)
C.O.P.
Air Flow Rate (Rated)
Indoor Sound Level (@1.5m)
Cool (kW)
13.5
15.4
22.0
27.5
Heat (kW)
14.2
16.3
23.2
29.6
Cool (kW)
4.8
5.9
8.1
10.4
Heat (kW)
4.3
4.8
7.2
10.4
C/H
2.81/3.29
2.61/3.38
2.74/3.24
2.64/2.90
l/s
925
1070
1017~1250
1250~1667
dBA
48
51
51
51
Std/Hi
Std/Hi
Std/Hi
Std/Hi
ESP Settings
Indoor Fan Speeds
Dimensions
(H x W x D)
Weight
Power Supply
Hi/Lo/LL
Hi/Lo/LL
Hi/Lo/LL
Hi/Lo/LL
Indoor (mm)
360 x 1478 x 899
360 x 1478 x 899
500 x 1210 x 850
500 x 1410 x 850
Outdoor (mm)
1170 x 900 x 320
1345 x 900 x 320
1220 x 1280 x 690
1440 x 1280 x 690
Indoor (kg)
64
66
78
97
Outdoor (kg)
101
112
180
206
Ø/V/HZ
3/415/50
3/415/50
3/415/50
3/415/50
Scroll
Scroll
Compressor Type
Scroll
Refrigerant
Refrigerant Control
Refrigerant Pipe Size
Scroll
R22
R22
Electronic
Capillary Tube
Liq (mm)
9.5 (Flared)
12.7 (Brazed)
15.9 (Brazed)
Gas (mm)
19.1 (Flared)
25.4 (Brazed)
28.6 (Brazed)
Drain Pipe Size
mm
Supply Air Conn.
mm
245 x 1152 (Flange)
245 x 1152 (Flange)
377 x 827 (Flange)
376 x 939 (Flange)
Return Air Conn.
mm
2 x 400 (Oval)
2 x 400 (Oval)
350 x 918 (Flange)
350 x 1118 (Flange)
Max Actual Pipe Length
m
50
50
50
50
Max Level Difference
m
30
30
30
30
Pre Charged Length
m
30
30
5
5
Cool (°CDB)
-5 to 46
-5 to 46
0 to 50
0 to 50
Heat (°CWB)
-10 to 15
-10 to 15
-10 to 15
-10 to 15
Pressure dBA (C/H)
50/53
55/57
61/63
62/64
Outdoor Operating Range
Outdoor Sound Level
@ 1 Metre from front of unit
ID Ø 25mm x OD Ø 32mm
PT 3/4 inches (Internal Thread)
•The cooling (or heating)
capacities will be reduced
below the rated values as
the outside temperature
approaches the maximum (or
minimum) temperature limits.
•Factory fitted soft starter is
standard on single phase
R(Y)71LUV19S & RY100LUV1S.
•Outdoor sound pressure levels
are determined in accordance
with JIS8615.
•Outdoor sound power levels
are determined in accordance
with EPA regulations (excludes
R(Y)125LU ~ R(Y)250LU).
•The Daikin 5 year warranty
applies only to products in
this brochure purchased and
installed in Australia or New
Zealand. It does not apply to
any non Daikin components
used in the installation
(eg ducting, air outlets, zone
motors etc).
•Due to ongoing product
development, specifications
are subject to change without
notice.
Due to ongoing product development, specifications are subject to change without notice.
14
14
Superior Technology
in Air Conditioning Solutions
Daikin’s comprehensive range of domestic and commercial
air conditioners provides superior comfort and efficiency to
any sized building or space.
From a small apartment to a multi-storey building, Daikin has the air
conditioning solution.
Research and development in the areas of mechanics, electronics and chemicals,
enables Daikin to select components that will work seamlessly together,
giving you an air conditioning system of the highest quality and reliability.
Daikin’s state-of-the-art management control and monitoring systems provide
added energy efficiency, improved maintenance and cost reduction for any
commercial air conditioning installation. Most Daikin units can
be incorporated into these management control systems.
Split System
A Daikin Split System will air condition one room
or an area of your home. Discreet wall-mounted
models, compact floor consoles and versatile floor
and ceiling units are all part of the Daikin range.
Split systems are available in Cooling Only and
Heating & Cooling, plus you can choose from
inverter and fixed speed, non-inverter models.
Super Multi-split Systems
A Daikin Multi-Split System can air condition up to nine rooms
using only one outdoor unit. Multi-Split Systems are ideal for
situations where there is limited space for outdoor units or
insufficient ceiling space for ducting. A Daikin Multi-Split System
allows individual control of the air conditioning in each room,
optimising comfort levels and making significant savings on
running costs, as wastage is eliminated by only air conditioning
rooms as you need to.
15
SkyAir
Easy installation and great flexibility makes SkyAir ideal for
shops, restaurants, offices, schools, showrooms and even larger
residential rooms. The SkyAir Super Inverter series can provide
significant savings on energy costs, compared to the
non- inverter equivalent models.
There is a wide selection of models available meaning SkyAir can
provide the answer to any air conditioning need.
Commercial
Daikin air conditioners are installed in thousands of commercial
buildings around Australia and are the preferred choice when
comfort, superior quality, flexibility and economy are key
requirements.
Daikin’s revolutionary VRV II (Variable Refrigerant Volume)
systems are dramatically changing the way a wide range of new
and existing high rise and low rise commercial buildings are air
conditioned. Compared to conventional systems, VRV II reduces
energy bills, lowers installation and operating costs and increases
occupant comfort, VRV II heat recovery systems provide further
energy savings.
Daikin also has a wide range of Ceiling-Mounted Ducted Air
Conditioners, Rooftop Packaged Units, Floor-Standing Packaged
Units and Chillers.
Controls
The Daikin Air Purifier
State of the art control systems
Using the world’s first Titanium Apatite Photocatalyst filter, Daikin Australia has
compatible with Daikin’s range of
introduced an air purifier that not only removes minute airborne particles from a
units deliver advanced monitoring and
room and gets rid of unpleasant odours but also adsorbs and deactivates viruses
management and superior levels of
and bacteria.
comfort control.
The Daikin Air Purifier is powerful yet quiet and energy efficient.
Its compact, attractive design and easy portability
makes it ideal for homes, offices, waiting rooms
and smaller shops and salons.
Four-directional suction allows the Air Purifier to
quickly draw in dust and odours from all parts of
the room and by distributing negative ions the
unit gives the air a healthy and refreshing feel.
16
Controlled comfort
at your fingertips
The BRC1D619 is a state of the art remote controller that
Optional Accessories
offers full control over your installation.
BRC1D619 – full function LCD wired remote controller.
With Daikin fully ducted air conditioners, you have total control of your
comfort. The BRC1D619 is a state of the art remote controller that offers
full control over your installation.
The basic control functions include turning your system on or off,
switching between the operating modes and temperature and air volume
adjustment. The controller also has a clock and day of the week indicator.
In addition, the controller features a built-in time clock for the convenience
of automated operation. Up to five actions per day (totaling 35 actions) can
be programmed into the controller and can be linked to a set temperature,
LIMIT operation or off command. The timer can be enabled or disabled at
any time.
Limit operation provides thermostat control within the range of the set
minimum and maximum temperature. The minimum temperature setting
will trigger heating; the maximum temperature setting will trigger cooling.
The leave home function if activated prevents the room temperature from
Programmable 7-day timeclock with temperature set-back control.
dropping when the occupants are out for a longer period. If the room
temperature drops below 10°C, heating is started automatically. As soon
as 15°C is reached, the controller returns to its original status.
Three hierarchical permission levels can be set to limit the user action if
required.
(RZQ71F, RZQ4P, RZQ5P, RZQ6P, RZQ7P, RZQ8P, RZQ9P, RZQ10P).
BRC2A51 – simple LCD wired remote controller.
BRC4C62 – infra-red wireless remote controller kit.
AKRCSO1-1 – room mounted remote temperature sensor.
KRP1B5X – adaptor PCB for field supplied electric
booster heater and outside air fan interlock.
KRP4A51 – adaptor PCB for external control
(e.g. timelock, BMS).
DCS302CA61 – centralised controller for up to 64 groups.
DST301BA61 – programmable Schedule Timer.
DTA102A52 – interface PCB for central control.
KKPJ5F180 – drain plug connection for outdoor units
KKP937A4 – drain plug connection for outdoor units
(RSX50F, RSX50F).
KMBK – indoor unit hanging kit (for suspending from
rafters or slabs) for FDY(P)71 ~ 160.
1
ON/OFF Button
Press the ON/OFF button to start or
stop the system.
13
Fan Speed Button
Selects between available fan
speeds.
2
OPERATION LAMP
The operation lamp lights up
during operation or blinks if a
malfunction occurs.
14
Air flow direction adjust
button
Adjusts air flow discharge direction
(not available on ducted units).
3
LEAVE HOME ICON
Shows the status of the Leave
Home function.
ON Leave Home is enabled
FLASHING Leave Home is active
OFFLeave Home is disabled
15
4
Operation Model icon
These icons indicate the current
operation mode (cooling, heating,
automatic changeover, program
dry, fan only).
Operation change/Min-Max
button
This is a multi purpose button.
Depending on the previous
manipulations of the user, it can
have the following functions.
a.Select the operation model of
the installation (cooling-heatingdry-fan only).
b.Toggles between the minimum
and maximum temperature when
in limit operation.
5
Maximum Set Temperature
When in limit operation,
this indicates the maximum
temperature that can be set on the
controller.
6
SCHEDULE TIMER AND
ACTION ICON
This indicates that the schedule
timer is active and displays the
actions for each day.
7
8
9
10
Minimum Set Temperature
When in limit operation,
this indicates the minimum
temperature that can be set on the
controller.
Day of the week indicator
Shows the current week day
or the set day when reading or
programming the schedule timer.
Clock Display
Indicates the current time or
the action time when reading or
programming the schedule timer.
Fan Speed icon
Indicates the set fan speed.
11
Set Temperature display
Indicates the current set
temperature.
12
NOT AVAILABLE
Displayed whenever a non installed
function is selected.
Excludes FDXS models
16
Set point/Limit button
Toggles between set point, limit
operation or OFF (programming
mode only).
17
Temperature adjust buttons
Used to adjust the current
set temperature or, when in
programming mode, to adjust the
programmed set point temperature.
18
Time adjust button
Used to adjust the clock or, when in
programming mode, to adjust the
programmed action time.
19
chedule Timer button
S
Enables or disables the schedule
timer.
20
Programming button
This is a multi purpose button.
Depending on the previous
manipulations of the user, the
programming button can have
various functions.
21
Inspection/Test operation
button
Not used – for service purposes only.
22
entilation Volume button
V
Active only when used in
conjunction with a Daikin heat
reclaim ventilator (HRV).
23
Ventilation Mode button
Active only when used in
conjunction with a Daikin heat
reclaim ventilator (HRV).
DASMS05 – Daikin i-text.
Standard
wall-mounted LCD
controller OPTIONAL
PROGRAMMABLE 7-DAY
timeCLOCK WITH TEMP.
BRC1D619
Optional
remote room
air temperature
sensor AKRCS01-1
4
3
Optional
infra-red
wireless remote
controller
BRC4C62
2
1
8
9
10
5
6
7
11
12
13
23
14
22
21
20 19 18
17
16 15
17
Warranty
The Daikin 5 year Parts and Labour Warranty applies only to products in this brochure
purchased and installed in Australia or to products in this brochure purchased and
installed in New Zealand. Applies to products on pages 5-14.
Environment Qualifications
Daikin Industries Limited have received ISO 14001 Environmental Certification for the Daikin
production facilities listed below. ISO 14001 is an international standard specifying requirement
for an environmental management system, enabling an organisation to formulate policy and
objectives, taking into account legislative requirements and information about significant
environmental impacts. It applies to those environmental aspects within the organisation’s control
and over which it can be expected to have an influence. The certification relates only to the
environmental management system and does not constitute any endorsement of the products
shipped from the facility by the International Organisation for Standardisation.
Head Office / Tokyo Office Certificate number: EC02J0355
Shiga Plant (Japan) Certificate number: EC99J2044
Sakai Plant (Japan) Certificate number: JQA-E-80009
Daikin Industries Ltd (Thailand) Certificate number: JQA-E-90108
Yodogawa Plant (Japan) Certificate number: EC99J2057
Quality Qualifications
Daikin Industries Limited is the first air conditioning equipment manufacturer in Japan to receive
ISO 9001 certification. All Daikin manufacturing facilities have been certified to ISO 9001 Quality
Management System requirements. ISO 9000 Series Certificate is awarded to suppliers fulfilling the
requirements of ISO standards. ISO 9001 is a certificate for quality assurance concerning
‘design, development, manufacturing, installation and related service’ of products
manufactured at that factory.
Residential Air Conditioning
Manufacturing Div. (ISO 9001)
JQA-0486 May 2, 1994 (Shiga Plant)
Industrial System and Chiller Products
Manufacturing Div. (ISO 9001)
JQA-0495 May 16, 1994 (Yodogawa Plant and Kanaoka
Factory and Kishiwada Factory)
Commercial Air Conditioning and Refrigeration
Manufacturing Div. (ISO 9001)
JMI0107 December 28, 1992 (Kanaoka Factory and Rinkai
Factory at Sakai Plant)
Daikin Europe N.V. (ISO 9001)
Lloyd 928589.1 June 2, 1993
Daikin Industries (Thailand) Ltd. (ISO 9001)
JQA-1452 September 13, 2002 (ISO 9001)
Daikin Australia Pty Limited (ISO 9001)
QEC 23256 31 May 2006
(Sydney, Melbourne, Brisbane,
Adelaide, Newcastle, Townsville)
That’s the Daikin difference
Daikin Australia Pty Limited ABN 62 000 172 967
Email sales@daikin.com.au Visit our website at www.daikin.com.au
For your nearest Daikin Dealer call 1300 368 300 (Australia only) or 1300 DAIKIN (Australia only)
0800 324 546 (New Zealand)
Dealer:
Locations: Sydney, Brisbane, Adelaide, Melbourne, Darwin, Newcastle, Townsville, Perth, Tasmania, Auckland
The specifications, designs and information in this brochure are subject to change without notice. Unit colours shown are as close as possible to actual unit colours. Colours depicted in this brochure may vary slightly.
PCDAU0202J/09/06
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising