BK Radio | GPH-CMD | GPH-CMD Operation and Programming

GPH-CMD Operation and Programming
GPH-CMD Operation and Programming
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Operation
Transmit Indicate
Programmable Switches
Busy Channel /Low Battery Indicate
Twenty channels per group.
No-stop knob. Radio Beeps at
upper and lower channel
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Operation
Keypad Lock
•Press and Hold FCN Key to
Lock or Unlock Keypad
•Radio beeps on key press
when locked
Empty Channels
• If No Active Transmit or Receive
Frequency is programmed the Radio
will Display “DISABLED” and Emit an
Alert Tone
No Transmit Frequency
•Receive Only Channels will Display
“No CH’ when attempting to Transmit
Edit Scan List
•With Scan Turned off press the ENT
Key to Add the Selected Channel to the
Scan List
• Press the CLR Key to Remove the
Channel From the Scan List
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Operation
Priority One Assignment
• With Scan Turned off press the PRI Key to Set
the Selected Channel as Priority One Channel
Keypad Function Select
• Press FCN Key to Scroll Programmed Functions
• Press PRI Key to Enable or
Disable the Displayed Function
•Factory Defaults: Repeater Talk-Around
and Multi-Group Scan
View Group Label
• Press and Hold the # Key to view the Current
Groups Label
Change Group
• Press # Key
• Use Number Keys to Select Desired Group
• Enter New Group
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Pick List Operation
Pick List Tone Selection
•Use Number Keys to Select a Transmit Code
Guard (1-32) from the Programmed Pick List
Note: Assigning a Transmit Code Guard to a
Channel Overrides User Select Operation
View Tone Setting
• Press FCN Key
• Press 1 Key
•Use PRI Key to Scroll Through the List or
Number Keys View Specific Tone
NOTE: This function may be disabled with the PC
Programming software
Edit Global Tone List
• Press and Hold FCN Key to Enter Program Mode
• Lear the Current Tone
•Use Number Keys to Select Desired Tone
•Enter New Tone
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Command Operation
Add Command Channel
• Press the * Key to Add Current Channel to
Command Group
• Channel is Assigned to Next Available
Command Channel
Selecting Command Group
• Press # Key Twice to Select Command Group
• Press Enter to Set Group
Remove Command Channel
• While operating in the Command Group Press *
Key to Remove the Current Channel from the
Command Group
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Command Operation
Delete Command Group
• A Long * Key Press Removes all Channels from
Command Group
• While Holding the * Key the Radio will Emit an
Alert Tone and Flash “Delete All”
• When Command Group is Empty a Lower Alert
Tone will Sound
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Programming
Enter Password
•Select Six Digit Password
•Press Enter Key
•Factory Default 000000
Group Parameters
•Use FCN Key to Scroll Through Settings
Group Options
•1-7 Reserved
•8- Add Group to Scan List
Group Label
•Clear Group Channel Label
•Use Number Keys to Select Desired Symbol
•Use FCN to shift left for next character
•Enter New Group Label
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Channel Settings
Channel Bandwidth
• Press the # key to toggle between wideband and
narrowband operation
Receive Frequency
•Press CLR to clear RX Frequency
• User the number keys to select desired frequency.
(136 to 174 MHz, 2.5kHz increments)
• Press the ENT key to set frequency
Receive Code Guard
• Press CLR to clear Code Guard
• User number keys to select desired frequency.
(67 to 255.9 Hz)
• Press ENT to set
• Press # key to enter Digital Coded Squelch
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Channel Settings
Transmit Frequency
• Press CLR to clear RX Frequency
• User the number keys to select desired frequency.
(136 to 174 MHz, 2.5kHz increments)
• Press the ENT key to set frequency
Transmit Code Guard
• Press CLR to clear Code Guard
• User number keys to select desired frequency.
(67 to 255.9 Hz)
• Press ENT to set
• Press # key to enter Digital Coded Squelch
Channel Label
•Clear Channel Label
•Use Number Keys to Select Desired Symbol
•Use FCN to shift left for next character
•Enter New Label
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Global Parameters
Global Parameters
• Use FCN Key to Scroll Through Settings
Global Password
• Press the CLR key
• Enter a new six-digit password
• Press the ENT key to store
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Global Parameters
Global Options 1
When a function is enabled, the corresponding number in
the display will flash.
When the function is disabled the number is steady.
To enable to disable a function press the number key
corresponding to that function.
1. Battery Saver Inhibit
When function 1 is enabled (flashing) the battery saver is turned off. The battery saver should be
turned off only for getting proper voltage readings during service or for systems requiring fast
squelch attack time.
2. Reserved for Future Option
3. Transmit on Priority One
When function 3 is enabled (flashing) transmissions will occur on PR1 channel when operating in
Single or Dual Priority Scan Mode
4. PRI Key Lockout
When function 4 is enabled (flashing) the PRI key is locked out in the Operating Mode. The user will
not be able to change the designation of the Priority 1 Channel.
5. Scan List Lockout
When function 5 is enabled (flashing), the user will not be able to change the channels in the Scan
List. When disabled (steady), the user can edit the Scan List using the ENT and CLR keys.
6. Backlight on Display Change
When function 6 is enabled (flashing), the display will light for the programmed duration on any
display activity.
7. Backlight on Key Press
When function 7 is enabled (flashing), the display will light for the programmed duration on any
key press.
8. Silent Mode
When function 8 is enabled (flashing), all radio alert tones are disabled
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Global Parameters
Global Options 2
When a function is enabled, the corresponding number in
the display will flash.
When the function is disabled the number is steady.
To enable to disable a function press the number key
corresponding to that function.
1. Reserved for Future Option
2&3. Busy Channel Operating Modes
Busy Channel Indicator - LED illuminates when a signal is received.
Busy Channel Lockout - LED illuminates and PTT disabled
Lockout Override - PTT can be activated by rotating Squelch knob off detent.
Operation
Function 2
Function 3
Indication
Disable (Steady)
Enable (Flashing)
Lockout
Enable (Flashing)
Enable (Flashing)
Override
Enable (Flashing)
Disable (Steady)
4&5. DTMF and ANI Settings
When function 4 is enabled (flashing) the ANI ID number is transmitted with each PTT
When function 5 is enabled (flashing) the keypad becomes active for manual DTMF
When functions 4 and 5 are both enabled (flashing) the ANI tone sequence is transmitted when the
ENT key is pressed while transmitting.
6-8. Reserved for Future Option
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Global Parameters
ANI
• Press the CLR key
• Enter a new DTMF ID Number (1-7 digits)
• Press the ENT key to store the new ID
TX Timeout Timer
• Advance Timeout Time by 15 Second
Intervals with PRI Key (0-225 seconds)
• Press Enter Key to Set
Scan Delay Timer
• Advance Can Hold Time by .5 Second
Intervals with PRI Key (0-7.5 seconds)
• Press Enter Key to Set
Backlight Settings
• Advance Backlight time by 1 second intervals
with PRI key (Always On, Always Off or 1- 7.5
seconds)
• Press Enter Key to set
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Programming Global Parameters
Priority 1 Settings
• Use Number Keys to Select Desired Priority
One Channel
• Enter New Channel
• Use Number Keys to Select Desired Priority
One Group
• Enter New Group
Priority 2 Settings
• Use Number Keys to Select Desired Priority
Two Channel
• Enter New Channel
• Use Number Keys to Select Desired Priority
Two Group
• Enter New Group
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Cloning
Select Target
• Enter the Cloning Mode by Pressing the * Key
• Select Target Radio Type with Long Press on * Key
• Target Radio Type Options GPHCMD or GPH
Select Data
• Select Data to be Cloned with Long Press on # Key
• Cloning Data Options:
Command Group,
Group 1-25,
User CG Pick List,
Global Data (GRP 00)
Data
Valid Target
GROUP 00
GPHCMD only
GROUP 01 - 25
GPHCMD, GPH
CMND GRP
GPHCMD, GPH
PICK LIST
GPHCMD only
Send Information
• Press FCN Key to Send Data
• Display Flashes While Cloning
• “Failure” Displayed if Data is Not Received by
Slave Radio
Note: Slave radios programmed to reject an incoming
clone will not display any special indication.
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
GPH-CMD Cloning
What Clones?
Data that can be cloned to another GPH-CMD:
Group Data – Frequencies, Code Guards, Scan List, Label
Command Group Data* - Frequencies, Code Guards, Scan List
Global Data (GRP 00) – Priority Channels, Timers, etc.
UTXG Pick List – 32 Tone Pick List
Data that can be cloned to a standard GPH:
Group Data – Frequencies, Code Guards, Scan List, Label
Command Group Data* - Frequencies, Code Guards, Scan List
The Master’s global data is converted to group data in the slave, and only the
first 16 channels are transferred.
When receiving an incoming clone from a GPH radio, the GPH-CMD radio
ignores group data other than the group label and the group scan list bit.
The GPH-CMD’s global data and channels 17-20 are not disturbed.
*When the Command Group is cloned the target group’s label will be set to “CMND CLN”.
RELM Wireless
Technical Support
www.relm.com
(800) 422-6281
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF