Agilent / HP 3386 / 3387 DC Module Connectors Manual

Agilent / HP 3386 / 3387 DC Module Connectors Manual
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
InstraView REMOTE INSPECTION
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
SM
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com
A
DC MODULE CONNECTORS
Standard Connector (P/N 5060-3386)
Relay Connector (P/N 5060-3387)
General Information
Load connections are made on the connector supplied
with each module. The connector is fastened to the back
of the mainframe. Modules can then be installed or
removed from the mainframe without disturbing the
wiring on the connector.
The connector has a switch to select either local or remote
voltage sensing, depending on how the load is connected.
A relay connector is identified by a check mark on the
Relay label on the connector. Relay connectors include
load and sense disconnect and polarity reversal relays.
Making Load Connections
Load connections are the same on both the standard and
the relay connector.
Open the Connector
Open the connector by loosening the four corner screws
(M3 X 10 mm).
Installation Guide
+Sense used to connect the + remote sense lead. Set the
sense switch to Remote when this connection is
used.
-Sense used to connect the - remote sense lead. Set the
sense switch to Remote when this connection is
used.
GND
CAUTION
used for signal ground (GND) connections.
The output connector ground terminal is a low
noise ground provided for convenience, such as
for grounding wire shields. This terminal is not
designed to function as an equipment safety
ground.
Connect the Wires
Loosen the barrier block screws and connect the wires.
The barrier block accepts spade or ring terminals. You
can also connect a stripped wire to the barrier block.
Twist the wire around under the screw terminal and
tighten the screw.
TIE
WRAP
CAUTION
• Hand tighten only.
• Start all screws
before tightening.
• Tighten screws evenly.
• DO NOT overtighten screws.
• DO NOT use locking-type
adhesive on the screws.
A five-terminal barrier block is provided for wire
connections. The barrier block screws are 6-32 x 1/4 inch
(equivalent p/n 2470-0001). The barrier block terminals
are labeled as follows:
+Output
used to connect the + output load wire.
-Output
used to conect the - output load wire.
Agilent p/n 5959-3366
Microfiche p/n 5959-3367
Route the wires out of the bottom of the connector as
shown in the figure above. Use the tie-wrap supplied
with the connector to secure the wires to the connector.
Close the Connector
Close the connector and tighten the four corner screws.
Observe the CAUTION on the figure.
Attach the Connector to the Mainframe
Attach the connector to the back of the module on the
mainframe at the appropriate slot location. Tighten the
two screws (M3 x 10mm) on the connector. Observe the
CAUTION on the figure.
Printed in Malaysia
November, 2006
*5959-3366*
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
CAUTION
• Hand tighten only.
• Start all screws
before tightening.
• Tighten screws evenly.
• DO NOT overtighten screws.
• DO NOT use locking-type
adhesive on the screws.
Open the Connector
Open the connector by loosening the four corner screws
(refer to the figure on the first page).
Remove the Standard Board
Remove any wiring from the five-terminal barrier block.
As shown in the following figure, spread the two plastic
tabs located on each side of the J601 connector and lift
the board out of the case.
2
Set the Sense Switch
Each connector has a local/remote sense switch. Unless
you are using remote sensing, make sure that the sense
switch is set to Local. Remote sensing is used in
applications that require voltage sensing directly at the
load.
Installing a Relay Board in a Standard
Connector
You can upgrade a standard connector to a relay
connector by removing the standard board (p/n 50656998 or older style 5060-3470) from inside the connector
and installing a relay board (p/n 5065-6999).
NOTE: The older style plug-in relay board (p/n 50603351) is no longer available and has been replaced by
relay board p/n 5065-6999.
1
1 - STANDARD BOARD
2 - SPREAD TABS TO REMOVE
Install the Relay Board
Orient the relay board so that the switch is in the opening
and snap the board into place. Reconnect the wiring on
the barrier block.
Close the Connector
Close the connector and tighten the four corner screws.
Observe the CAUTION on the figure on the first page.
With a marker, check the Relay box on the connector
label to indicate that a relay board is installed.
Agilent p/n 5959-3366 page 2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
InstraView REMOTE INSPECTION
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
SM
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement