ACCESS CONTROL READER
Cat. No. 75A00-2
Installation Instructions and User’s Guide
INSTALLATION
DI-021-AX752-05A
AR2243
(75I00-2)
ENGLISH
WARNINGS AND CAUTIONS
• Read and understand all instructions. Follow all warnings and instructions marked on the product.
• Do not use this product near water - e.g., near a tub, wash basin, kitchen sink or laundry tub, in a wet basement, or near a swimming pool.
• Never push objects of any kind into this product through openings, as they may touch dangerous voltages.
• SAVE THESE INSTRUCTIONS.
DESCRIPTION
WARNINGS AND CAUTIONS
• Never install communications wiring or components during a lightning storm.
• Never install communications components in wet locations unless the components are designed specifically for use in wet locations.
• Never touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.
• Use caution when installing or modifying communications wiring or components.
The 75A00-2 Access Control Reader is a 125 KHz high security, digitally encrypted, 26-bit proximity card reader that connects to a serial port on an Leviton Home Control System for access control. Multiple 75A00-2 readers may be multi-dropped on a single serial interface configured for RS-485 communications.
The 75A00-2 incorporates three inputs: 1 input for an exit push button, and 2 general purpose inputs. The 75A00-2 also incorporates one output for the electric door strike or magnetic lock.
PLANNING
The 75A00-2 requires 4 wires for operation (2 for power and 2 for communications). The maximum distance between the 75A00-2 and the connected 12V Power Supply or Leviton
83A00 Power Hub is based on two factors: 1) the current draw of the connected door lock device, and 2) the wire gauge/type used. To maintain proper operation of the 75A00-2 and the connected door lock device, do not exceed the "Maximum Cable Length" based on the Total Current Draw and the Wire Gauge/Type per the table below (Table 1).
75A00-2 Only (no Door Lock connected): 130mA maximum
Wire
Gauge
Wire
Type
Number of positive conductors
24 solid 1
24
24 solid solid
2
3
22 solid 1
22 solid 2
22 stranded 1
18
18 solid stranded
1
1
16 solid 1
16 stranded 1
Number of ground conductors
1
2
3
1
1
1
2
1
1
1
75A00-2 and Door Lock (800mA): 930mA maximum
Maximum
Cable
Length (feet)
233
466
699
413
826
381
1000
963
1000
1000
Wire
Gauge
Wire
Type
Number of positive conductors
24 solid 1
24
24 solid solid
2
3
22 solid 1
22 solid 2
22 stranded 1
18
18 solid stranded
1
1
16 solid 1
16 stranded 1
Number of ground conductors
1
1
2
1
1
1
1
2
3
1
Maximum
Cable
Length (feet)
37
74
110
65
130
60
165
152
262
242
75A00-2 and 79A00-1 Electric Door Strike (450mA): 580mA maximum
Wire
Gauge
Wire
Type
Number of positive conductors
24 solid 1
24
24 solid solid
22 solid 1
2
3
22 solid 2
22 stranded 1
18
18 solid stranded
1
1
16 solid 1
16 stranded 1
Number of ground conductors
1
2
3
1
1
1
2
1
1
1
Maximum
Cable
Length (feet)
58
117
175
103
207
95
261
241
415
383
Wire
Gauge
75A00-2 and Door Lock (1A): 1.13A maximum
Wire
Type
Number of positive conductors
24 solid 1
24
24 solid solid
22 solid 1
2
3
22 solid 2
22 stranded 1
18
18 solid stranded
1
1
16 solid 1
16 stranded 1
Number of ground conductors
1
1
2
1
1
1
1
2
3
1
Maximum
Cable
Length (feet)
108
50
136
126
217
200
30
61
91
54
Note: If cable with multiple conductors is used (such as Cat-5 cable), it is possible to connect multiple conductors together to achieve greater distance.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
LEVITON LIMITED WARRANTY
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from defects in material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II and Lumina Pro: three (3) years from installation or 42 months from manufacture date.
• OmniLT, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date.
• Batteries: Rechargeable batteries in products are warranted for ninety (90) days from date of purchase. Note: Primary (non-rechargeable) batteries shipped in products are not warranted.
Products with Windows ® Operating Systems: During the warranty period, Leviton will restore corrupted operating systems to factory default at no charge, provided that the product has been used as originally intended. Installation of non-Leviton software or modification of the operating system voids this warranty. Leviton’s obligation under this Limited Warranty is limited to the repair or replacement, at Leviton’s option, of Product that fails due to defect in material or workmanship. Leviton reserves the right to replace product under this Limited Warranty with new or remanufactured product.
Leviton will not be responsible for labor costs of removal or reinstallation of Product. The repaired or replaced product is then warranted under the terms of this Limited Warranty for the remainder of the Limited Warranty time period or ninety (90) days, whichever is longer. This Limited Warranty does not cover PC-based software products. Leviton is not responsible for conditions or applications
beyond Leviton’s control. Leviton is not responsible for issues related to improper installation, including failure to follow written Installation and operation instructions, normal wear and
tear, catastrophe, fault or negligence of the user or other problems external to the Product. To view complete warranty and instructions for returning product, please visit us at www.leviton.com.
© 2013 Leviton Mfg. Co., Inc.
For Technical Assistance Call: 800-824-3005 - www.leviton.com
DI-021-AX752-05A
AR2243
INSTALLATION
The 75A00-2 requires the use of one serial port on the Leviton controller. Run the cable (as determined by Table 1) from the Leviton controller or
Leviton 83A00 Power Hub to the location of the Model 75A00-2 Access Control Reader and install as follows:
1) Remove the cover from the 75A00-2 by gently prying the top and bottom of the cover with a small blade screwdriver.
2) Drill a ½” hole in the center of the mounting location for the 75A00-2. The 75A00-2 may be mounted on a mullion or wall.
3) Insert the connections cable from the 75A00-2 into the hole. Mark the mounting holes locations on the top-right and bottom left.
4) Make the connections to the 75A00-2 as shown in Figure 2 or Figure 3.
5) Secure the 75A00-2 to the mounting surface using the supplied mounting hardware.
6) Install the cover by gently pushing it onto the reader until it snaps in place.
7) Configure the serial interface on the Leviton controller for RS-485 communications by moving the corresponding interface jumper (JP1-JP5) to the "485" position.
+12 VDC
GND
12 VDC
POWER SUPPLY
24 VAC
INPUT
POWER TRANSFORMER
24 VAC 40 VA
CONTACT
INPUT #2
CONTACT
INPUT #1
BLUE
BLACK
YELLOW
BLACK
GREEN
BLACK
REQUEST TO
EXIT BUTTON
75A00-2 ACCESS
CONTROL READER
WHITE (-)
RED (+)
12VDC ELECTRIC
DOOR STRIKE
Color
Red
Black
Gray
Orange
White
Green
Blue
Yellow
Purple
Brown
Connection
Power (+12VDC)
Power Ground (GND)
RS-485 (A)
RS-485 (B)
Door Lock Output
Exit Button Input
Contact Input #1
Contact Input #2
Not Used
Not Used
RED
BLACK
- GRAY WIRE ON TOP - TAB UP -
A
B
GRAY
ORANGE
4 POSITION MODULAR CONNECTOR
ADDITIONAL READERS CONNECT IN PARALLEL
TOP
WHEN A SERIAL INTERFACE IS CONFIGURED FOR ACCESS
CONTROL, THE CORRESPONDING INTERFACE JUMPER
(JP1-JP5) MUST BE IN THE "485" POSITION.
FOR EXAMPLE: JP2 MUST BE SET TO "458" WHEN SERIAL
INTERFACE 2 (J2) IS USED FOR ACCESS CONTROL.
SIDE
CONTACT
INPUT #2
CONTACT
INPUT #1
BLUE
BLACK
YELLOW
BLACK WHITE (-)
RED (+)
Figure 1 - Mounting the Model 75A00-2
GREEN
BLACK
REQUEST TO
EXIT BUTTON
75A00-2 ACCESS
CONTROL READER
Color
Red
Black
Gray
Orange
White
Green
Blue
Yellow
Purple
Brown
Connection
Power (+12VDC)
Power Ground (GND)
RS-485 (A)
RS-485 (B)
Door Lock Output
Exit Button Input
Contact Input #1
Contact Input #2
Not Used
Not Used
12VDC ELECTRIC
DOOR STRIKE
HAI MODEL 83A00
12VDC POWER HUB
HAI CONTROLLER
WHEN A SERIAL INTERFACE IS CONFIGURED FOR ACCESS
CONTROL, THE CORRESPONDING INTERFACE JUMPER
(JP1-JP5) MUST BE IN THE "485" POSITION.
FOR EXAMPLE: JP2 MUST BE SET TO "458" WHEN SERIAL
INTERFACE 2 (J2) IS USED FOR ACCESS CONTROL.
Figure 3 – Connections to the 83A00 Power Hub
Figure 2 - Connections to the 75A00-2
SPECIFICATIONS
Read Range: 78A00-1 Cards = 4 inch; 78A00-2 Key Tags = 2 inch
Door Open Time:
Current Consumption:
Communications:
Inputs:
Lock Output: 12VDC, 1A maximim
Lock Type: Fail Safe or Fail Secure (selectable)
LED Indicators:
Beeper:
Operating Temperature:
Operating Humidity:
5 Seconds (default), 1-60 Seconds (selectable)
130mA maximum
RS-485
3 inputs (Exit Button, Input 1, Input 2)
Array of 3 LED indicators (Red and Green)
Piezoelectric
-31°F to 140°F
10% to 90% relative humidity, non-condensing
Dimensions: 1.8”W x 4.9”H x 0.8”D
Weight: 80g (0.18 lb.)
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Copyright and Trademark Information
This document and all its contents herein are subject to and protected by international copyright and other intellectual property rights and are the property of Leviton Manufacturing
Co., Inc, its subsidiaries, affiliates and/or licensors. © 2013 Leviton Manufacturing Co., Inc. All rights reserved.
Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed without the express written permission of Leviton Manufacturing Co., Inc.
For Technical Assistance Call: 800-824-3005 - www.leviton.com
DI-021-AX752-05A
AR2243