4100C125

4100C125
Factory
Field
Optional
High Voltage
Heat Strip #1
3
1
3
3
1
5
1
Limit
Switch
Limit
Switch
4
84
3
9
Black/White
L2
Heater
Contactor
#2
T2 T1
L2
L1
208/230-60-1
220/240-50-1
Per Nameplate
Circuit Breaker #2
66
Blue
Blue
66
Blk/White
Red
33
Red
Black
Black/White
Brown
71
79
L1
69
70
82
55
81
69
65
73
73
A
Emergency
Heat Relay
4
72
B
Circuit Breaker #1
31
77
Ground
52 Lug
76
67
68
Orange
Orange
Grn
4 3
5
29
Green
24
Red/Yellow
Black
6
Brown
L1
L2
Ckt B
7
Heater
Contactor
#1
T2 T1
Brown
L2
L1
Ckt A
63
Brown
83
Black
D Labeled wires connect if no options used.
56
2 1
Indoor Blower Motor
Orange
Orange
Brown
Black/White
Black
Red/Yellow
Red
240
208
C
COM
Red
27
32
3
2
6
5
Low Ambient
Bypass (Opt.)
1
57
Black
Blk
Terminal
Dual Can
Capacitor 17 Block #2
C
Red
Black
Black
Black
H
13
7
12
Low Ambient
Control (Opt.)
12
Outdoor Fan Motor
12
R
S
C
Compressor
C
C
Defrost Control
51
SEN
JMP
SENSOR
42
TERM SPEED
TEMP
UP
30 60 90
45
44
28
LC L1 L0
High
Press.
Switch
Green
2 1
39
T1
T2
9
L
L1
42
47
Brown
Yellow
Black/White
Tan
T1
T2
Terminal
Block #3 10
F
H
4
27
Y
CC
30
Black/White
Ground
36
46
60
Transformer
E
41
Black/White
40
COM
L2 RV
Yellow/Red
26
NC
Upper Control Panel
Black/White
R
38
Yellow
Red/White
26
LO
R R
W2 B
Low Pressure
Switch
S
S
Defrost
Sensor
C RV TWV
Reversing
Valve
Gnd
Terminal
Block #5
11
Lower Control Panel
T2
34
Condenser Section
Black/White
T1
48
58
27
Black
36
49
37
Black
L
35
Purple/White
Pressure Lockout
61 Indicator
C
L2
Tan
B W2 R
Black
Pink
Black
Y
Pink
L1
59
33
Black
Blk/Whte
Brown
Blue
Black
Purple
Orange
G2
Compressor
Contactor
11
Black/White
G
43 F
Terminal
Block #2
Black
L
4102-080
29
31
Blue
12
Blue
DH
11
Blue
Black/White
Blue
Blue
C
W3
9
10
Yellow
Blue/Black
Red/White
G
2
3
4
Purple
Blue
R
1
Red/Black
Blue
Brown
Yellow
Blue/Red
B
W2
7
8
3
Plug #1
Red
Yellow
L2
Black
Y
1
2
Yellow
Blue
5
6
25
Plug #3
Red/White
Red
Brown/White
W1
L1
Black
O1
4
Red
L
230/208-60-1
2 1
Black/White
Yellow
3
Pink
Red/Yellow
2
3
Brown/White
Blk/Whte
E
1
1
2
3
4
5
6
7
8
9
10
11
12
Red/Whte
Orange
Orange
Purple
G
Plug #2
Red/White
Y1
Plug #2
Brown
Low Voltage
Terminal Block
24
Yellow
"X" Thermostat Option
Red/Whte
15 14 12 10 9 6
23
Brown
C
Blue
B
E Move Red wire to 208V tap for 208V operation.
Install jumper for hi speed blower oper. on
F models 36, 42, 48, and 60.
Remove jumper when Low Amb. Bypass is
H installed.
Blue
A
208/230-60-1
220/240-50-1
Per Nameplate
64
80
Brown
6
Red
Blue
2
3
Line 2 to
Power Source
1
Blue
Composite Wiring Diagram QH Series 3
230/208-60-1, Represents Max. KW Electric Heat
Heat Strip #2
Line 1 to
Power Source
Low Voltage
Jumper Bar
USE COPPER CONDUCTORS *ELECTRICAL SHOCK HAZARD
ONLY SUITABLE FOR AT LEAST *DISCONNECT POWER BEFORE
75° C.
SERVICING.
Red
4100C125
DANGER
!
Red
WARNING
!
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project