Datalogic | GRYPHON Mx30 | Gryphon™ - Barcode + POS Solution Center

Gryphon™ - Barcode + POS Solution Center
Gryphon™
Dx30 Readers
QUICK REFERENCE
820001611 (Rev. B)
UPDATES AND LANGUAGE AVAILABILITY
UK/US
The latest drivers and documentation updates for this product
are available on Internet.
Log on to : www.datalogic.com
I
Su Internet sono disponibili le versioni aggiornate di driver e
documentazione di questo prodotto. Questo manuale è
disponibile anche nella versione italiana.
Collegarsi a : www.datalogic.com
F
Les versions mises à jour de drivers et documentation de ce
produit sont disponibles sur Internet. Ce manuel est aussi
disponible en version française.
Cliquez sur : www.datalogic.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und
Dokumentation von diesem Produkt. Die deutschsprachige
Version dieses Handbuches ist auch verfügbar.
Adresse : www.datalogic.com
E
En Internet están disponibles las versiones actualizadas de los
drivers y documentación de este producto. También está
disponible la versión en español de este manual.
Dirección Internet : www.datalogic.com
USING GRYPHON™ DX30 READERS
Gryphon™ guns automatically scan barcodes at a distance.
Simply aim and pull the trigger. Code scanning is performed
along the center of the light bar emitted from the reading
window. This bar must cover the entire code.
Successful scanning is obtained by tilting the scanner with
respect to the barcode to avoid direct reflections which impair
the reading performance, see the figure above.
Successful reading is signaled by an audible tone plus a
good-read green spot.
CONNECTIONS
RS232
USB
(if required)
IBM USB POS
PEN
WEDGE
WEDGE
DISCONNECTING THE CABLE
INTERFACE SELECTION
Follow the procedure to configure the interface required by your
application.
-
USB Interface
RS232 Interface
Wedge Interface
Pen Interface
USB INTERFACE CONFIGURATION
The USB interface is compatible with:
Windows 98 (and later)
IBM POS for Windows
Mac OS 8.0 (and later)
4690 Operating System
START-UP
As with all USB devices, upon connection, the Host performs
several checks by communicating with the Gryphon™. During
this phase the green LED on the Gryphon™ reader blinks and
normal operations are suspended. Two basic conditions must
be met before Gryphon™ is ready to read codes, the correct
USB driver must be loaded and sufficient power must be
supplied to the reader.
For all systems, the correct USB driver for the default USB-KBD
interface is included in the Host Operating System and will
either be loaded automatically or will be suggested by the O.S.
and should therefore be selected from the dialog box (the first
time only).
If the Host supplies sufficient power to the reader, the start-up
phase ends correctly, the green LED stops blinking and the
reader emits the beep OK signal.
If the Host does not supply sufficient power to the reader, a
dialog box will appear on the Host and the reader will be
blocked (green LED continues blinking). In this case,
disconnect the USB cable at the Host (green LED stops
blinking), connect and power-up an external supply to USB
cable then reconnect the USB cable to the Host and close the
dialog box. The reader emits the beep OK signal. You can now
read codes. At this point you can read the USB interface
configuration code according to your application. Load drivers
from the O.S. (if requested). When configuring the USB-COM
interface, the relevant files and drivers must be installed from
the USB Device Installation software which can be downloaded
from the web site http://www.datalogic.com.
The reader is ready.
First Start-Up
Connect
Gryphon™ to Host
Green LED blinks
Load drivers
(if requested)
Green LED off
Disconnect reader
at Host
YES
Connect external
power supply to
cable and power up
BEEP OK
Does a dialog
box appear
warning that Bus
power is not
sufficient?
NO
Green LED off - BEEP OK
Select desired USB
interface code
(USB-KBD is default)
Reconnect reader
cable to Host and
close dialog box
Load drivers
(if requested)
Read test codes.
Reader is READY
Successive start-ups will automatically recognize the previously
loaded drivers. If external power is used, verify that external
power is already supplied.
Successive Start-Ups
Connect Gryphon™
to Host
Disconnect reader
at Host
Connect external
power supply to
cable and power up
YES
Green LED blinks
Does a dialog box
appear warning
that Bus power is
not sufficient?
NO
Green LED off - BEEP OK
BEEP OK
Reconnect reader
cable to Host and
close dialog box
Read test codes.
Reader is READY
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-KBD-APPLE
Ì$+UA05$-FÎ
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Table Top
Ì$+UA00$-(Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
* When configuring USB-COM, the relevant files and drivers
must be installed from the USB Device Installation software,
which can be downloaded from the web site
http://www.datalogic.com.
USB KEYBOARD NATIONALITY
USB-KBD users should select one of the following keyboard
nationality codes.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA
Ì$+FJ0$-|Î
Japanese
Ì$+FJ8$-=Î
RS232 READER CONFIGURATION
Read the restore default code, then read the interface selection
code for your application.
RESTORE DEFAULT
Ì$+$*oÎ
RS232
Standard
Ì$+CP0$-$Î
POS SYSTEMS
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
WEDGE READER CONFIGURATION
Read the restore default code, then read the interface selection
code for your application.
RESTORE DEFAULT
Ì$+$*oÎ
WEDGE
IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
IBM XT
Ì$+CP503$-vÎ
PC Notebook
Ì$+CP505$-ÈÎ
IBM SURE1
Ì$+CP506$-$Î
IBM Terminal 3153
Ì$+CP504$-}Î
WEDGE (CONTINUED)
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read the
correct key transmission code. Select the keyboard type if
necessary (default = advanced keyboard).
KEY TRANSMISSION MODE
make-only keyboard
Ì$+CP502$-oÎ
make-break keyboard
Ì$+CP501$-hÎ
KEYBOARD TYPE
advanced keyboard
Ì$+FK1$-ÉÎ
typewriter keyboard
Ì$+FK0$-ÄÎ
ALT MODE
The following interface selection allows barcodes sent to
the PC to be interpreted correctly independently from the
Keyboard Nationality used. You do not need to make a
Keyboard Nationality selection.
(default = Num Lock Unchanged)
Make sure the Num Lock key on your keyboard is ON.
IBM AT - ALT mode
Ì$+CP507$-+Î
PC Notebook - ALT mode
Ì$+CP508$-2Î
WEDGE (CONTINUED)
WYSE TERMINALS
ANSI Keyboard
Ì$+CP509$-9Î
PC Keyboard
Ì$+CP510$-gÎ
ASCII Keyboard
Ì$+CP511$-nÎ
VT220 style Keyboard
Ì$+CP514$-ÇÎ
DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx
Ì$+CP512$-uÎ
APPLE
APPLE ADB Bus
Ì$+CP513$-|Î
WEDGE KEYBOARD NATIONALITY
Wedge users should select one of the following wedge
keyboard nationality codes.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA
Ì$+FJ0$-|Î
The following Keyboard Nationality selection is only valid for
IBM AT compatible PCs:
Japanese
Ì$+FJ8$-=Î
PEN READER CONFIGURATION
Read the restore default code, then read the pen interface
selection code.
RESTORE DEFAULT
Ì$+$*oÎ
PEN
Ì$+CP6$-BÎ
DEFAULT VALUES
USB DEFAULT SETTINGS
DATA FORMAT: code identifier disabled, no field adjustment,
code length not transmitted, character replacement disabled.
KEYBOARD: USA keyboard, FIFO enabled, intercharacter and inter-code delays disabled, USB keyboard
speed normal.
USB
USB COM:
no handshaking, delay disabled, rx timeout 5 sec.,
ack/nack disabled, FIFO enabled, serial trigger lock disabled.
Default Headers and Terminators for each USB mode:
- USB-KBD: no header, terminator = ENTER
- USB-KBD-ALT-MODE: no header, terminator = CR
- USB-COM: no header, terminator = CR-LF
- USB-IBM-TABLE TOP: not applicable
- USB-IBM-HAND HELD: not applicable
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled.
DATA FORMAT: code identifier disabled, no field adjustment,
code length not transmitted, no header, terminator = CR-LF,
character replacement disabled.
RS232 Nixdorf DEFAULT SETTINGS
9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking
hardware (RTS/CTS), delay disabled, rx timeout 9.9 sec.,
ack/nack disabled, FIFO disabled, serial trigger lock disabled.
DATA FORMAT:
code identifier enabled, no field adjustment,
code length not transmitted, no header, terminator = CR,
character replacement disabled.
RS232 Fujitsu DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 2 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled.
DATA FORMAT: code identifier enabled, no field adjustment,
code length not transmitted, no header, terminator = CR,
character replacement disabled.
RS232 ICL DEFAULT SETTINGS
9600 baud, parity even, 8 data bits, 1 stop bit, handshaking
RTS always on, delay disabled, rx timeout 9.9 sec., ack/nack
disabled, FIFO enabled, serial trigger lock disabled.
DATA FORMAT: code identifier enabled, no field adjustment,
code length not transmitted, no header, terminator = CR,
character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition
enabled, num lock unchanged, inter-character and intercode delays disabled.
DATA FORMAT:
code identifier disabled, no field adjustment,
code length not transmitted, no header, terminator =
ENTER, character replacement disable.
PEN EMULATION DEFAULT SETTINGS
interpret mode, conversion to code 39 disabled, output level
normal, idle level normal, minimum output pulse 600 µs,
overflow medium, inter-block delay disabled.
POWER SAVE
scan rate 270scans/s, standby disabled, sleep state/USB
suspend disabled.
READING PARAMETERS
hardware trigger, trigger active level, no trigger timeout,
Flash On = 1 sec, Flash Off = .6 sec, one read per cycle,
safety time .5 sec, beeper intensity high, tone 2, beeper type
monotone, beeper length short, good read spot duration
medium, automatic operation aiming light enabled.
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit
control enabled, Puzzle Solver™ disabled, decoding safety
= one read.
CODE SELECTION
Enabled codes
•
•
•
•
•
Code PDF417 (only Gryphon™ D230)
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length
code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99
characters
Code 128
variable length code; 1-99 characters
Disabled codes:
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical
codes, MSI, Plessey, Telepen, Delta IBM, Code 11,
Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined.
OPERATING TEST
Read the TEST codes below.
EAN-8
1234 5670
EAN-13
1 234567 000992
Code 39 (Normal)
1
7
1
6
2
Code 128
t
e
s
t
Interleaved 2 of 5
0123456784
PDF417
DATALOGIC PDF417 Test Code
YOUR READER IS NOW READY TO READ CODES.
To change the defaults refer to the “Gryphon™ Dx30/Mx30
Reference Manual”, part number 90ACC1930, or to the
DL Sm@rtSet™ Configuration program, both downloadable
from the website.
TECHNICAL FEATURES
Gryphon™ Dx30
Electrical Features
Power Supply
Consumption:
Maximum
Operating
Sleep mode/USB Suspend
Max. Scan Rate
Reading Indicators
5 Vdc ± 5%
Gryphon D130
Gryphon D230
270 mA@ 5 Vdc 270 mA@ 5 Vdc
165 mA@ 5 Vdc 210 mA@ 5 Vdc
<500 µA@ 5 Vdc
4 mA@ 5 Vdc
270 scans/sec
LED, Good Read Spot, Beeper
Optical Features
Sensor
Illuminator
Wavelength
Max. LED Output Power
LED Safety Class
Reading Field
Max. Resolution
PCS (Datalogic Test Chart)
CCD solid state (3648 pixels)
LED array
630 ~ 670 nm
0.33 mW
Class 1 EN 60825-1
see reading diagram
Gryphon Dx30-Std
Gryphon D130-LR
0.076 mm (3 mils)
0.11 mm (4.3 mils)
min. 15%
Environmental Features
Working Temperature
Storage Temperature
Humidity
Drop Resistance
Protection Class
0 °C to + 55 °C / 32° to +131 °F
-20 °C to + 70 °C / -4° to +158 °F
90% non condensing
IEC 68-2-32 Test ED
1.8 m (5 ft. 11 in.)
IP30
Mechanical Features
Weight (without cable)
Cable Length
about 210 g. (7.4 oz.)
2 m. (6 ft. 6 in.)
READING DIAGRAMS
GRYPHON™ D130
Reading diagram at 25 °C and 300 lux ambient lighting
Reading Zones (10° skew angle)
15
10
5
0.13 mm
(5 mils)
0
EAN13 M=1
0.33 mm
(13 mils)
CODE 39
0.50 mm
(20 mils)
-5
-10
-15
0
5
10
15
20
25
30
35
(cm)
GRYPHON™ D130-LR
Reading diagram at 25 °C and 300 lux ambient lighting
Reading Zones (10° skew angle)
15
10
5
EAN13 M=1
0.33 mm
(13 mils)
CODE 39
0.13 mm
(5 mils)
CODE 39
0.50 mm
(20 mils)
0
-5
-10
-15
0
5
10
15
20
25
30
35
40
45
50
55
(cm)
GRYPHON™ D230
Reading diagram at 25 °C and 300 lux ambient lighting
Reading Zones (10° skew angle)
10
5
0.13 mm
(5 mils)
0
EAN13 M=1
0.33 mm
(13 mils)
CODE39
0.50 mm
(20 mils)
-5
-10
0
5
10
15
20
25
(cm)
30
Reading diagram at 25 °C and 300 lux ambient lighting Reading
Zones (10° skew angle)
8
PDF417 Aspect Ratio 3:1
6
4
2
0.17 mm
(6.6mils)
0.38 mm
(15mils)
0
-2
-4
-6
0.25 mm
(10mils)
-8
0
2
4
6
8
10
12
14
(cm)
WARRANTY
Datalogic warranties this product against defects in
workmanship and materials, for a period of 5 years from the
date of shipment, provided that the product is operated under
normal and proper conditions.
Datalogic has the faculty to repair or replace the product, these
provisions do not prolong the original warranty term.
The warranty does not apply to any product that has been
subject to misuse, accidental damage, unauthorized repair or
tampering.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support
through its website. Log on to www.datalogic.com and click on
the links indicated for further information including:
•
PRODUCTS
Search through the links to arrive at your product page
where you can download specific Manuals and Software
& Utilities including:
- DL Sm@rtSet™ a Windows-based utility program
which allows device configuration using a PC. It
provides RS232 interface configuration as well as
configuration barcode printing.
•
SERVICES & SUPPORT
- Datalogic Services - Warranty
Maintenance Agreements
Extensions
and
- Authorised Repair Centres
•
CONTACT US
E-mail form and listing of Datalogic Subsidiaries
PATENTS
This product is licensed under the following U.S. patent:
6,158,661
This product is covered by one or more of the following patents:
U.S. patents 5,992,740; 6,305,606 B1; 6,517,003 B2;
6,631,846 B2; 6,712,271 B2; 6,808,114 B1; 6,817,525 B2; and
6,834,806 B2
European patents 851,378 B1; 895,175 B1; 962,880 B1;
997,760 B1; 1,128,315 B1; and 1,164,536 B1
Additional patents pending.
COMPLIANCE
FCC COMPLIANCE
Modifications or changes to this equipment without the
expressed written approval of Datalogic could void the authority
to use the equipment.
This device complies with PART 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
which may cause undesired operation.
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
LED CLASS
TO EN60825-1:(2001)
POWER SUPPLY
This device is intended to be connected to a UL Listed/CSA
Certified computer which supplies power directly to the reader
or else be supplied by a UL Listed/CSA Certified Power Unit
marked
“Class
2”
or
LPS
power
source
rated
5 V, minimum 270 mA, which supplies power directly to the
reader via the power connector of the cable.
WEEE COMPLIANCE
DATALOGIC S.p.A.,
Via Candini, 2
40012 - Lippo di Calderara
Bologna - Italy
06
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
Gryphon D1XX
Gryphon D2XX
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below:
sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:
den nachstehenden angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista
siguiente:
89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC
and
et
und
y
emendamenti successivi
further amendments
ses successifs amendements
späteren Abänderungen
succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità
elettromagnetica ed alla sicurezza dei prodotti.
On the approximation of the laws of Member States relating to electromagnetic
compatibility and product safety.
Basée sur la législation des Etats membres relative à la compatibilité
électromagnétique et à la sécurité des produits.
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf
elektromagnetische Verträglichkeit und Produktsicherheit entsprechen.
Basado en la aproximación de las leyes de los Países Miembros respecto a la
compatibilidad electromagnética y las Medidas de seguridad relativas al producto.
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con la siguientes normas:
AND
EN 55022 (CLASS B ITE), AUGUST 1994:
LIMITS
AMENDMENT A1 (CLASS B ITE), OCTOBER 2000: MEASUREMENTS
METHODS
OF
OF
RADIO
DISTURBANCE
OF
INFORMATION
TECHNOLOGY EQUIPMENT (ITE)
EN 55024, SEPTEMBER 1998:
INFORMATION
EQUIPMENT.
TECHNOLOGY
IMMUNITY
CHARACTERISTICS.
LIMITS
AND
METHODS OF MEASUREMENTS
Lippo di Calderara, February 24th, 2006
Ruggero Cacioppo
Quality Assurance Laboratory Manager