CALOG - TC The CALOG - TC is a high precision, multi-functional, hand-held calibrator suitable for the process control industry. It’s speciality is thermocouple based instruments. It measures and sources, thermocouple, millivolts and milliamps. It can measure DC Volts and continuity. The trend feature is ideal for graphing temperature profiles and PID controller optimization. It’s small size, long battery life and high precision make the CALOG - TC ideal for industrial field or workshop calibration. Measures and sources types: J, K, T, E, R, S, B and N Thermocouples. Configurable internal or manual cold-junction compensation, in either °C, °F, Kelvin or Rankine. Accuracy is better than 0.5°C, excluding cold junction errors and thermocouple errors. The CALOG - TC has a resolution of 0.1°C. Measures and sources -10 to 100mV with 0.01% accuracy and 1µV resolution. It can simultaneously source a thermocouple and measure mA (isolated). The trend feature is useful for temperature graphs or controller optimising. MEASURING TC ANALOGUE INPUT RANGES 0 to 24mA 0 to 32V -10 to 100mV Thermocouple types are the K, J, T, B, R, S, E, N. C(W5) and D(W3) (IEC 584-3). OR mA mV V IMPEDANCE Input impedance ±17W Input impedance ±110kW Input impedance > 1MW Input impedance > 1MW ACCURACY 0.01% 0.005% 0.01% 0.05% RESOLUTION 1µA 1mV 1µV 0.1°C SOURCING ANALOGUE OUTPUT RANGES 0 to 24mA -10 to 100mV Thermocouple types are the K, J, T, B, R, S, E, N. C(W5) and D(W3) (IEC 584-3). ISOLATION Max 100VDC between mV/TC output and mA input circuits IMPEDANCE Max load 500W Min. load 600W Min. load 600W ACCURACY 0.01% 0.01% 0.05% RESOLUTION 1µA 1µV 0.1°C CALOG Calibrators The CALOG range of process instrumentation calibrators are designed for servicing, repairs in the workshop and the plant environment. They are tough, sophisticated precision instruments that are portable, compact and userfriendly. Robust enough to withstand the rigors of most industrial environments, they are powered by long-life Nickel metal hydride batteries, monitored by ‘fuel gauges’ and incorporate a clear, back-lit graphic display. For quick source value set-up, the CALOG uses the “key-per-digit” numeric setting feature that enables the user to scroll each digit up or down. The graphic display can be selected to display the measured value or trend with programmable time base. Features 1 1 1 1 1 1 Small, rugged, handheld with a protective rubber cover. Graphic display of measured value, percent and battery status Contain serial technology components for compact size, accuracy and reliability Programmable auto-off, restart at last setting and selectable display resolution NiMH Battery pack, charger, carry case, and test leads supplied as standard 1 year guarantee Environmental 1 1 1 Operating temperature range Storage temperature range Humidity 0 to +50°C -20 to +55°C <85% non-condensing Mechanical Specifications 1 1 1 1 Dimensions (with the boot on) Dimensions (without the boot on) Protection Weight 85 x 155 x 43mm, IP54 rating (dust and splash proof) 77 x 145 x 34mm, IP54 rating (dust and splash proof) UL 94 V-0 flame retardant ABS plastic with rubber boot 340g General Specifications 1 1 1 1 Display Keypad Batteries Battery life Error messages 1 1 1 1 Over range Under range mA loop error mA loop ohms to high 128 x 64 graphics display with back-lit LCD 16 Key embossed buttons NiMH battery pack with temperature sensing Approx. 10 Hours, loop power enabled sourcing 12mA Approx. 50 Hours, loop power disabled with audible warning with audible warning “loop error” with audible warning “check loop W” with audible warning Distributed by www.calogcalibrators.co.za Rev 1.0 - 31/01/2006
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement