INSTALLATION GUIDE

V100DC

10A SPDT Enclosed Relay

10-30 VDC Coil

Installer’s Specifications

Operating Temperature -34°C to 60°C (-29° to 140°F)

Operating Humidity

Expected Relay Life

10-90% non condensing

Electrical (at rated current): 100,000 cycles

Mechanical

LED ON=energized Relay Status

Wire Specifications:

Lead Length

Gauge

Insulation Class

Agency Approvals

14” (356mm) min.

UL1015; Coil: 18 AWG; Contacts: 16 AWG

600 VAC RMS

UL508 enclosed device listing

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.

• This equipment must only be installed and serviced by qualified electrical personnel.

• Read, understand and follow the instructions before installing this product.

• Turn off all power supplying equipment before working on or inside the equipment.

• Use a properly rated voltage sensing device to confirm power is off.

DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION

Failure to follow these instructions will result in death or serious injury.

NOTICE

• This product is not intended for life or safety applications.

• Do not install this product in hazardous or classified locations.

• The installer is responsible for conformance to all applicable codes.

• Mount this product inside a suitable fire and electrical enclosure.

DIMENSIONS

2.9"

(74 mm)

INSTALLATION

Disconnect and lock out all power sources before beginning the installation.

1. Using the threaded nipple, connect the relay to the desired enclosure through a knock out hole.

2. Secure with the conduit nut provided.

3. Connect Coil:

• Choose the coil common lead (white with yellow stripe) and connect it to the (-) source termination point.

• Choose the low voltage (10-30 VAC/DC, white with blue stripe) lead, and connect it to the (+) source termination point.*

4. Connect Relay Contacts:

• Choose the relay common wire (yellow) and connect to switched load.

• Choose the relay N.O. (orange) and/or* N.C. (blue) lead and connect to switched load.

5. Secure the enclosure and reconnect power.

* Isolate or insulate all non-terminated wires according to local electrical code requirements, i.e. wire nut.

2.8"

(71 mm)

1.6"

(41 mm)

1.7"

(43 mm)

1/2" NPT Nipple

1.8"

(46 mm)

Z203521-0B PAGE 1 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / [email protected] 03121

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.

TM

WIRING COLOR CODES

CONTROL SYSTEM INPUT

LOW wht/blue blue

White

10-30VDC blue

COMM wht/yellow yello w White

Common yello w

CONTACT AND COIL SPECIFICATIONS

TYPICAL COIL PERFORMANCE

Pull in Voltage DC

10-30V..................................... 9

Drop Out Voltage DC

10-30V..................................... 3

Voltage Coil Current

DC

10V.......................................... 14mA

12V.......................................... 14mA

24V.......................................... 16mA

30V.......................................... 18mA

CONTACT RATINGS

Resistive.............. 10A@277VAC, 28VDC

Motor.................... 120VAC, 1/3HP N.O. & 1/6HP N.C.

240VAC, 1/3HP N.O. & 1/6HP N.C.

277VAC, 1/4HP N.O. & 1/8HP N.C.

Pilot Duty............. 277VAC, (1.7A), 480VA N.O.

Ballast.................. 277VAC, 1.7A

Tungsten............... 120VAC, TV3 N.O. TV2 N.C.

Gold Flash............. Yes

CONTACT OUTPUT

N.C.

V100DC

INSTALLATION GUIDE

WIRING EXAMPLE

Nipple mount directly to a panel

To Load CONT

ACTS

YELLOW

Common

COIL

To Controls

ORANGE

N.O.

Nipple mount to any 2x or 4x electrical box

To Load CONTACTS

CO

IL

Wire

Nut

To Controls

Z203521-0B PAGE 2 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / [email protected] 03121

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement