AC Drives Selection Chart
15H
18H
22H Regenerative
Main Attributes
Analog Mircrodrive; V/Hz ; Open Chassis or Basic V/Hz Control, 300-800 Hp NEMA 1
NEMA 4X enclosures, compact and low cost enclosure
Closed loop vector, 300-800 Hp NEMA 1
enclosure, zero speed torque, auto motor
tuning, digital speed and torque control
22H is a version of the 18H with a
Regenerative front end
300 to 800
300 to 800
10 to 50
460V
3-Phase
460V
3-Phase
230V/460V 3-Phase
NEMA 1 (300-800 Hp)
NEMA 1 (300-800 Hp)
IP20
V/Hz
Closed Loop Vector Only
Closed Loop Vector
20:1
1000:1
1000:1 Closed Loop Vector
Unit Handling
Motors
Definite Purpose
Motors
Series 5
Farm Duty
Motors
Inverter/Vector Motors & Controls
1/2 to 5
Voltage Range
115V/230V 1-Phase
230V/460V 3-Phase
Brake Motors
Hp Range
Chassis or NEMA 4X/12
Control Mode
V/Hz
Speed Range (Typ.)
20:1
200 & 575 Volt
Motors
Enclosure Selection
None
Option Cards for RS232/RS485, DeviceNet, Option Cards for RS232/RS485, DeviceNet, Option Cards for RS232/RS485, DeviceNet,
Profibus and Modbus
Profibus and Modbus
Profibus and Modbus
Operator Interface
Analog Controls
Local or Remote (NEMA 4)
Mounted 32 character
alpha-numeric LCD display
Local or Remote (NEMA 4)
Mounted 32 character
alpha-numeric LCD display
IEC Frame
Motors
Communications Options
Local or Remote (NEMA 4)
Mounted 32 character
alpha-numeric LCD display
Easy-to-Use Basic Startup Menu; Runs
Easy-to-Use Basic Startup Menu, Runs
Easy-to-Use Basic Startup Menu; Runs
Regenerative Applications
Right Out of the Box; Optional I/O Expansion Right Out of the Box; Optional I/O Expansion Right Out of the Box; Optional I/O Expansion
Cards
Cards
and Speed Feedback Cards
50 Hertz
Motors
Differentiating Feature
VS-Master, RPM-AC,
ZDM VectorDuty®,
ZDNM VectorDuty,
ZDWNM VectorDuty
VS-Master, RPM-AC,
ZDM VectorDuty, ZDNM VectorDuty,
ZDWNM VectorDuty
DC Motors
and Controls
NEMA 1 CSM and JMSM
NEMA 4X CWDSM
Soft Starters &
Dynamic Brakes
M & CP Standard-E®,
EM & ECP Super-E´®
Inverter/Vector
Motors & Controls
Matched Performance® Motors
­291
Farm Duty
Motors
Inverter/Vector Motors & Controls
Series 5
Micro Inverters
Definite Purpose
Motors
1/2 thru 2 Hp
1/2 thru 2 Hp
2 thru 3 Hp
1 thru 5 Hp 97-132 VAC
195-265 VAC
195-265 VAC
323-529 VAC
1
1
3
3
Phase
Phase
Phase
Phase
-
50/60
50/60
50/60
50/60
Applications: Variable torque, constant torque or constant horsepower
applications. New installations, replacements and original equipment
manufacturers (OEM).
Unit Handling Motors
Features: NEMA 4X or open chassis mount standard. Output frequency 0.25
to 120 Hz with peak overload capacity of 150%. Separate accel/decel rates
and controlled reversing.
Brake Motors
200 & 575 Volt
Motors
Design Specifications
• PWM output
• Accel/decel rate adjustment
• Controlled reversing
• Adjustable current limit
• I2t motor overload protection
• Adjustable slip compensation
• Min/max output
frequency adjustment
• Selectable auto/manual restart
Operator InterfaceEnclosed Units
• Start/Stop command
• NEMA 4X enclosure
• Power on/off
• Rotary speed control
• Fwd/Rev optional
• Auto/Manual optional
Environmental and
Operating Conditions
• Input voltage:
1 phase 115 VAC ±15%,
1 phase 230 VAC ±15%
3 phase 230V ±15%
3 phase 460 ± 15%
• Input frequency
50 or 60Hz ±10%
• Service factor - 1.0
• Duty - continuous
• Humidity - 90% max RH non-condensing
• Altitude - 3300 feet max without derate
• Chassis mount or NEMA 4X enclosure
as standard
IEC Frame
Motors
Overload Capacity
150% for 120 seconds
Voltage - 3 Phase
0-230 VAC (RMS), 0-460 V AC (RMS)
Control
Spec
Control Method
Sinewave carrier input, PWM output
PWM Frequency
Rated 8.0 kHz
V/Hz Ratio
Factory set for optimum output
Torque Boost
Factory set for 60 Hz motors. Adjustable 6-30% for 50 Hz motors
Current Limit
Adjustable 63 to 188% of rated output
Frequency Setting
0-5 VDC, 0-10 VDC with external resistor network, non-isolated input
Accel/Decel
Separate accel/decel rates, 0.3-20 sec for 60 Hz motors
50 Hertz
Motors
Output
Ratings
Protective Features
• Selectable automatic restart at
momentary power loss
• Power indicator
• Status indicator
• Adjustable time base overload
• Electronic in rush current limiting
Adjustable 0-30% max
0-200%
0.3-20 Sec
Combined accel/decel for 50 Hz motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
­292
Hz
Hz
Hz
Hz
Protective
Functions
Ambient
Conditions
Inverter Trip
Over voltage, over current, under voltage, motor overload, output short circuit
Status Indicators
Tricolor LED indicator for status and green LED indicator for power on
Short Circuit
Output phase to phase
Temperature
0-45˚C
Cooling
Convection 1/2 - 2 Hp; Forced Air 3-5 Hp
Enclosure
Open chassis
0-50°C
Convection
NEMA 4X (IP65)
Series 5 Micro Inverters continued…
120 Sec.
List
Price
Mult.
Sym.
Ap’x.
Shpg.
Wgt.
Dimensions in/(mm)
Outside
H
Mounting
W
D
H
W
Open Chassis Mount – Single Phase Input
0.5/0.37
115/230
2.4
3.6
ID56F50-CO
383
E9
4
4.3
3.9
2.75
3.8
2.5
1/0.75
115/230
4
6
ID5601-CO
464
E9
5
4.3
3.9
5
3.87
3.7
2/1.5
115/230
5.5
8.25
ID5602-CO
603
E9
6
4.67
5.58
5.7
3.87
2.5
Open Chassis Mount – Three Phase Input
2/1.5
230
6.7
10.1
ID5202-CO
731
E9
5
8.55
4.68
4.5
6.5
3.9
3/2.25
230
8.8
13.2
ID5203-CO
770
E9
5
8.55
4.68
4.5
6.5
3.9
1/0.75
460
2.5
3.75
ID5401-CO
796
E9
5
8.55
4.68
4.5
6.5
3.9
2/1.5
460
4
6
ID5402-CO
817
E9
5
8.55
4.68
4.5
6.5
3.9
3/2.25
460
4.5
6.75
ID5403-CO
840
E9
5
8.55
4.68
4.5
6.5
3.9
5/3.7
460
7.6
11.4
ID5405-CO
1,072
E9
5
8.55
4.68
4.5
6.5
3.9
6
7.13
6.25
2.75
6
9.53
5.51
5.86
8.85
–
NEMA 1 Enclosed - Single Phase Input
1/0.75
115/230
4
6
ID5601-EO
559
E9
Definite Purpose
Motors
Cont.
Catalog
Number
Unit Handling
Motors
Hp/kW
Output
Current
Brake Motors
Input
Voltage
Farm Duty
Motors
Inverter/Vector Motors & Controls
115/230
3.6
5.4
ID5601-WO
740
E9
1/0.75
115/230
3.6
5.4
ID5601-BO
694
E9
6
9.53
5.51
5.86
8.85
–
2/1.5
115/230
5.5/6.7
8.3/10.0
ID5602-WO
1,044
E9
6
9.8
7.55
7.25
9.25
1
2/1.5
115/230
5.5/6.7
8.3/10.0
ID5602-BO
985
E9
8
9.8
7.55
7.25
9.25
1
NEMA 4X Enclosed – Three Phase Input
3/2.25
230
9
13.5
ID5203-WO
1,183
E9
6
9.8
7.55
7.25
9.25
1
3/2.25
230
9
13.5
ID5203-BO
1,125
E9
6
9.8
7.55
7.25
9.25
1
3/2.25 (1)
460
4.6
6.9
ID5403-WO
1,253
E9
6
9.8
7.55
7.25
9.25
1
(1)
460
4.6
6.9
ID5403-BO
1,194
E9
6
9.8
7.55
7.25
9.25
1
5/3.7
460
8.3
12.45
ID5405-WO
1,333
E9
6
9.8
7.55
7.25
9.25
1
5/3.7
460
8.3
12.45
ID5405-BO
1,276
E9
6
9.8
7.55
7.25
9.25
1
3/2.25
50 Hertz
Motors
(1) Jumper configurable for 1 HP and 2 HP
Note: -WO is white in color -BO is black in color; -EO is NEMA 1.
IEC Frame
Motors
1/0.75
200 & 575 Volt
Motors
NEMA 4X Enclosed – Single Phase Input
List
Price
Mult.
Sym.
Ap’x.
Shpg.
Wgt.
ID5RGA-1
Dynamic braking kit for open chassis 115/230V 1/2 Hp
and 1 Hp rated controls
236
E9
3
ID5SI-1
Signal isolator for open chassis units
Provides isolation for up to 24 VDC and 4-20mA command signals and run relay output. Select
relay as N.O. or N.C. contacts rated at 125 VAC @ 0.5A
206
E9
4
ID5SI-2
Signal isolator for NEMA 4X enclosed units
Provides isolation for up to 24 VDC and 4-20mA command signals.
233
E9
1
ID5AMS-1
Auto/Manual selection switch for NEMA 4X enclosed units
Allows selection of remote or on-board speed commands
57
E9
1
ID5FRS-1
Forward/Stop/Reverse selection switch for NEMA 4X enclosed units
Allows selection of forward or reverse motor direction commands
32
E9
1
ID5FRS-2
Forward/Stop/Reverse selection switch for NEMA 1 enclosed units.
Allows selection of forward or reverse motor direction commands.
32
E9
1
DC Motors
and Controls
Description
Soft Starters &
Dynamic Brakes
Catalog
Number
Inverter/Vector
Motors & Controls
Series 5 Options
­293
Farm Duty
Motors
Inverter/Vector Motors & Controls
Series 15H Inverter
300 thru 450 Hp
3 Phase - 50/60 Hz
Definite Purpose
Motors
Applications: Constant torque, variable torque or constant horsepower
applications. New installations, replacements and original equipment
manufacturers (OEM).
Unit Handling Motors
Features: NEMA 1 enclosure as standard. Output frequency 0.25 to 400 Hz
with peak overload capacity of 170-200%. Separate accel/decel rates and
controlled reversing. Built in two and three input PID process control loop.
Brake Motors
200 & 575 Volt
Motors
Design Specifications
• Process follower 0-5 VDC,
0-10 VDC, 4-20 mA
• Free run or ramp stop
• Selectable preset speeds
• Jog speed
• Dynamic braking (optional on
size C2 and larger)
• DC injection braking
• 2 analog meter outputs
• 2 opto isolated outputs
• 2 relay outputs
• Through wall & panel mount
size C2, E and F.
Output
Ratings
IEC Frame
Motors
Input
Ratings
50 Hertz
Motors
Control
Spec
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
­294
460 VAC
Protective
Functions
LCD
Display
Ambient
Conditions
Overload Capacity
Operator Keypad
• Forward/Reverse command
• Motor RUN and JOG
• Local/Remote key
• Stop command
• Parameter setting and display
• 32 character display
• Remote mount to 100 feet (60m)
from control
• NEMA 4X enclosure
when mounted on panel
Environmental and
Operating Conditions
• Input voltage
3 phase 200-240 VAC ±10%
3 phase 378-480 VAC ±10%
3 phase 573-600 VAC ±10%
• Input frequency 50 or 60Hz ±5%
• Service factor - 1.0
• Duty - continuous
• Humidity - 90% max RH non-condensing
• Altitude - 3300 feet (1000m)
max without derate
Protective Features
• Selectable automatic restart at
momentary power loss
• DC bus charge indicator
• Fault indicator
• Adjustable time based overload
• Cause of last 31 trips retained
in memory
• Digital display for fault conditions
• Linear heat sink thermal sensor
• Isolated control circuitry
150% for 60 seconds; 170-200% for 3 seconds for constant torque
115% for 60 seconds for variable torque
Frequency
0.25-400 Hz
Voltage
0-Maximum input voltage (RMS)
Frequency
50 or 60 Hz ± 5%
Voltage
180 - 264 VAC; 340 - 528 VAC, 515 - 660 VAC
Phase
Three phase (or single phase with derate)
Impedance
1% minimum for size C2, F, G and G2 (3% minimum required for size A, B, D and E)
Control Method
Sinewave carrier input, PWM output
PWM Frequency
Adjustable 1-5 kHz standard, 1-15 kHz quiet
V/Hz Ratio
Linear to squared reduced, base frequency, output voltage, minimum frequency limit, maximum frequency limit
Torque Boost
0-15% of input voltage; automatic with manual override
Brake Torque
20% standard on -E and -W; and -EO requires external assembly
Skip Frequency
Three zones 0-Max frequency
Frequency Setting
0-5 VDC, 0-10 VDC, 4-20mA, digital via optional RS232/485
Accel/Decel
Separate accel/decel rates, 0-3600 sec to maximum frequency
Inverter Trip
Over voltage, over current, under voltage, external trip, heatsink thermal, motor overload
Stall Prevention
Over voltage suppression, overcurrent suppression
External Output
OPTO isolated outputs, relay outputs, and LED indicator for trip
Short Circuit
Phase to phase, phase to ground
Running
Output frequency, set frequency, output current(%), voltage, RPM, custom units
Setting
Parameter values for setup and review
Trip
Separate message for each trip, cause of last 31 trips retained in memory
Temperature
-10 to + 40˚C For UL Listing
Cooling
Forced air included when required
OPTIONS: See pages 301-302 for optional Expansion Boards including RS-232, RS-485 isolated input etc.
See page 299 for optional Dynamic Braking Assemblies.
Normal Duty
Continuous
Amps
Peak Amps
List
Price
Mult.
Sym.
E1
460 Volts - Three Phase
G2
300
370
630
350
420
490
57,720
G2
350
420
720
400
480
560
67,835
E1
ID15H4400-EO
G2
400
480
820
450
540
620
75,461
E1
ID15H4450-EO
G
450
540
855
500
590
680
88,091
E1
Dimensions in/(mm)
Size
Outside
Mounting
Height
Width
Ap’x
Shpg. Wgt.
Height
Width
Depth
G
93/(2362)
31.5/(800)
23.6/(600)
Floor Mount
700
G2
65.98/(1676)
31.6/(803)
23.49/(597)
Floor Mount
600
200 & 575 Volt
Motors
OPTIONS: See pages 301-302 for optional Expansion Boards. See page 299 for optional Dynamic Braking Assemblies.
See notes on inside back flap.
Brake Motors
Unit Handling
Motors
ID15H4300-EO
ID15H4350-EO
IEC Frame
Motors
Hp
50 Hertz
Motors
Peak Amps
Inverter/Vector
Motors & Controls
Hp
Continuous
Amps
DC Motors
and Controls
Heavy Duty
Size
Soft Starters &
Dynamic Brakes
Catalog
Number
Farm Duty
Motors
Series 15H Inverter Drive Output Ratings
Definite Purpose
Motors
Inverter/Vector Motors & Controls
­295
Farm Duty
Motors
Inverter/Vector Motors & Controls
Series 18H Vector Drive 300 thru 450 Hp
3 Phase - 50/60 Hz
Definite Purpose
Motors
Applications: Constant torque or constant horsepower applications. New
installations, replacements and original equipment manufacturers. (OEM).
Unit Handling Motors
Features: NEMA 1 enclosure as standard. Output frequency 0-500Hz with
peak overload capability of 170-200%. Automatic tuning to motor and full
rated torque down to zero speed. Digital speed or torque control. Built in two
and three input PID process control loop.
Brake Motors
200 & 575 Volt
Motors
Design Specifications
• Motor shaft orient to marker
• Process follow +5VDC 0-5 VDC,
+10VDC 0-10 VDC ,4-20mA,
digital via keypad or optional
RS232/485
• Linear or S-curve deceleration
• 15 preset speeds
• 2 assignable analog outputs
• 2 assignable opto outputs
• 2 assignable relay outputs
• 2 assignable analog inputs
• Through wall and panel mount
size C2, E and F
Output
Ratings
IEC Frame
Motors
Input
Ratings
50 Hertz
Motors
Control
Spec
Inverter/Vector
Motors & Controls
Motor
Feedback
DC Motors
and Controls
Protective
Functions
LCD
Display
Soft Start & Dynamic
Brakes
­296
460 VAC
Ambient
Conditions
Overload Capacity
Operator Keypad
• Forward/Reverse command
• Motor RUN and JOG
• Local/Remote key
• Stop command
• 32 character display
• Remote mount to 100 feet (60m)
from control
• NEMA 4X enclosure when
mounted on panel
Environmental and
Operating Conditions
• Input voltage
3 phase 200-240 VAC +10%
3 phase 378-480 VAC +10%
3 phase 573-600 VAC +10%
• Input frequency
50 or 60Hz +5%
• Service factor - 1.0
• Duty - continuous
• Humidity - 90% max RH non-condensing
• Altitude - 3300 feet (1000m)
max without derate
Protective Features
• Adjustable current limit
• Isolated control circuitry
• Digital display for fault conditions
• Selectable automatic restart at
momentary power loss
• DC bus charge indicator
• Cause of last 31 trips retained
in memory
150% for 60 seconds, 170-200% for 3 seconds for constant torque
115% for 60 seconds for variable torque
Frequency
0-500 Hz
Voltage
0-maximum input voltage (RMS)
Frequency
50 or 60 Hz ±5%
Voltage
180 - 264 VAC; 340 - 528 VAC; 515 - 660 VAC
Phase
Three phase (or single phase with derate)
Impedance
1% minimum for size C2, F, G, and G2 (3% minimum required for Size A, B, D and E)
Control Method
Microprocessor controlled PWM output
PWM Frequency
Adjustable 1-5kHz STD, 1-16 kHz quiet
Speed Setting
±5 VDC, 0-5 VDC ±10 VDC, 0-10 VDC, 4-20 mA; digital via keypad, RS232/485
Accel/Decel
0-3600 sec.
Motor Matching
Automatic tuning to motor with manual override
Feedback Type
Incremental encoder coupled to motor shaft
Pulses/Rev
60 -15,000 selectable, 1024 standard
Voltage Output
2 channel in quadrature, 5 VDC, differential
Marker Pulse
Required for position orientation
Power Input
5 VDC, 300 mA maximum
Max. Frequency
1 MHz
Positioning
Buffered encoder pulse train output for position loop controller
Vector Trip
Missing control power, over current, over voltage, under voltage, motor over speed
Over temperature (motor or control), output shorted or grounded, motor overload
External Output
LED indicator for trip conditions, 4 assignable logic outputs, 2 assignable analog outputs 0-5 VDC
Short Circuit
Phase to phase, phase to ground
Running
Output frequency, motor RPM; output current, voltage (selectable)
Setting
Parameter values for setup and review
Trip
Separate message for each trip, last 31 trips retained in memory
Temperature
-10 to 40˚C for UL listing
Cooling
Forced air included when required
OPTIONS: See pages 301-302 for optional Expansion Boards including RS-232, RS-485. See page 299 for enclosure Dimensions.
See page 300 for optional Dynamic Braking Assemblies.
Heavy Duty
Catalog
Number
Size
ZD18H4300-EO
Normal Duty
Hp
Continuous
Amps
Peak Amps
List
Price
Mult.
Sym.
Hp
Continuous
Amps
G2
300
370
630
350
420
490
64,891
E1
ZD18H4350-EO
G2
350
420
720
400
480
560
75,461
E1
ZD18H4400-EO
G2
400
480
820
450
540
620
83,488
E1
ZD18H4450-EO
G
450
540
855
500
590
680
98,472
E1
Peak Amps
Unit Handling
Motors
460 Volts - Three Phase
Farm Duty
Motors
Series 18H Vector Drive Output Ratings
Definite Purpose
Motors
Inverter/Vector Motors & Controls
NOTE: -MO suffix indicates a protected chassis enclosure (not NEMA 1). See notes on inside back flap.
OPTIONS:See pages 301-302 for optional Expansion Boards. See page 300 for optional Dynamic Braking Assemblies.
93/(2362)
31.5/(800)
23.6/(600)
Floor Mount
700
G2
65.98/(1676)
31.6/(803)
23.49/(597)
Floor Mount
600
200 & 575 Volt
Motors
G
IEC Frame
Motors
Width
50 Hertz
Motors
Height
Ap’x
Shpg.Wgt.
Depth
Inverter/Vector
Motors & Controls
Mounting
Width
DC Motors
and Controls
Outside
Height
Soft Starters &
Dynamic Brakes
Size
Brake Motors
Dimensions in/(mm)
­297
Farm Duty
Motors
Inverter/Vector Motors & Controls
Series 22H Line
Regenerative Vector
Drive
10 thru 50 Hp
10 thru 50 Hp
3 Phase - 50/60 Hz
3 Phase - 50/60 Hz
Definite Purpose
Motors
Applications: Variable torque, constant torque or constant horsepower
applications. New installations, replacements and original equipment
manufacturers. (OEM).
Unit Handling Motors
Features: NEMA 1 enclosure as standard. Output frequency 0-500Hz with
peak overload capability of 170-200%. Automatic tuning to motor and full
rated torque down to zero speed. Digital speed or torque control. Built in two
and three input PID process control loop.
Brake Motors
200 & 575 Volt
Motors
Design Specifications
• Process follower
±5VDC 0-5 VDC,
±10VDC, 0-10 VDC ,
4-20mA, digital via keypad
or optional RS232/485
• Linear or S-curve deceleration
• Controlled reversing
• 15 preset speeds
• 2 assignable analog outputs
• 2 assignable logic outputs
• 2 assignable relay outputs
• 2 assignable analog inputs
• Motor shaft orient to marker
Output
Ratings
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
­298
230 VAC
460 VAC
Input
Ratings
Control
Spec
Motor
Feedback
Protective
Functions
Overload Capacity
Operator Keypad
• Forward/Reverse command
• Motor RUN and JOG
• Local/Remote key
• Stop command
• 32 character display
• Remote mount to 100 feet (60m)
from control
• NEMA 4X enclosure when
mounted on panel
Environmental and
Operating Conditions
• Input voltage
Three phase 200-240 VAC +10%
Three phase 378-480 VAC +10%
• Input frequency
50 or 60Hz +5%
• Service factor - 1.0
• Duty - continuous
• Humidity - 90% max RH non-condensing
• Altitude - 3300 feet (1000m)
max without derate
Protective Features
• Adjustable current limit
• Isolated control circuitry
• Digital display for fault conditions
• Selectable automatic restart at
momentary power loss
• DC bus charge indicator
• Cause of last 31 trips retained
in memory
150% for 60 seconds, 170-200% for 3 seconds for constant torque
115% for 60 seconds for variable torque
Frequency
0-500 Hz
Voltage
0-Maximum input voltage (RMS)
Frequency
50 or 60 Hz ±5%
Voltage
180 - 264 VAC; 340 - 528 VAC
Phase
Three phase
Impedance
3.0% minimum required
Control Method
Microprocessor controlled PWM output
PWM Frequency
Adjustable 1-5kHz STD, 1-16 kHz quiet
Speed Setting
±5 VDC, 0-5 VDC ±10 VDC, 0-10 VDC, 4-20 mA; digital via keypad, RS232/485
Accel/Decel
0-3600 sec
Motor Matching
Automatic tuning to motor with manual override
Feedback Type
Incremental encoder coupled to motor shaft
Pulses/Rev
60-15,000 selectable, 1024 standard
Voltage Output
2 channel in quadrature, 5 VDC, differential
Marker Pulse
Required for position orientation
Power Input
5 VDC, 300 mA maximum
Max. Frequency
1 MHz
Positioning
Optional buffered encoder pulse train output for position loop controller
Vector Trip
Missing control power, over current, over voltage, under voltage, motor over speed
Over temperature (motor or control), output shorted or grounded, motor overload
External Output
LED indicator for trip conditions, 4 assignable logic outputs, 2 assignable analog outputs 0-5 VDC
Short Circuit
Phase to phase, phase to ground
Running
Output frequency, motor RPM; output current, voltage (selectable)
Setting
Parameter values for setup and review
Trip
Separate message for each trip, last 31 trips retained in memory
Ambient
Temperature
-10 to +40˚C for UL listing
Conditions
Cooling
Forced air included when required
LCD
Display
OPTIONS: See pages 301-302 for optional Expansion Boards including RS-232, RS-485.
Size
Heavy Duty
Hp
Continuous
Normal Duty
Hp
Continuous
Peak
List
Price
Mult.
Sym.
56
10
28
32
10,488
E1
Peak
230 Volts - Three Phase
ZD22H210-EL
C+
10
28
ZD22H215-EL
C+
15
42
72
15
42
48
11,655
E1
ZD22H220-EL
C+
20
55
110
20
55
62
13,645
E1
ZD22H225-EL
C+
25
68
116
25
68
78
15,939
E1
ZD22H230-EL
D+
30
80
136
30
80
92
17,333
E1
ZD22H240-EL
D+
40
105
200
40
105
120
21,583
E1
ZD22H250-EL
D+
50
130
225
50
130
150
26,493
E1
460 Volts - Three Phase
ZD22H410-EL
C+
10
15
30
10
15
17
10,920
E1
ZD22H415-EL
C+
15
21
36
15
21
24
11,877
E1
ZD22H420-EL
C+
20
27
50
20
27
31
13,831
E1
ZD22H425-EL
C+
25
34
58
25
34
39
15,585
E1
ZD22H430-EL
D+
30
40
70
30
40
46
17,593
E1
ZD22H440-EL
D+
40
55
100
40
55
63
21,701
E1
ZD22H450-EL
D+
50
65
115
50
65
75
26,186
E1
Farm Duty
Motors
200 & 575 Volt
Motors
NOTE: See notes on inside back flap.
OPTIONS: See pages 301-302 for optional Expansion Boards.
Definite Purpose
Motors
Catalog
Number
Unit Handling
Motors
Series 22H Line Regenerative Vector Drive Output Ratings
Brake Motors
Inverter/Vector Motors & Controls
Cable Extension
Length
List
Price
Mult.
Sym.
Approx.
Shpg. Wgt.
CBLH015KP
5 feet (1.5 meter)
84
E8
1
CBLH030KP
10 feet (3.0 meter)
119
E8
1
CBLH046KP
15 feet (4.6 meter)
152
E8
1
CBLH061KP
20 feet (6.1 meter)
254
E8
2
CBLH091KP
30 feet (9.1 meter)
389
E8
3
CBLH152KP
50 feet (15.2 meter)
509
E8
3
CBLH229KP
75 feet (22.9 meter)
559
E8
4
CBLH305KP
100 feet (30.5 meter)
693
E8
5
50 Hertz
Motors
Catalog
Number
Inverter/Vector
Motors & Controls
For the convenience of our customers, we offer a connector plug/cable assembly.
This assembly provides the connectors from the keypad to the control for remote keypad operation.
IEC Frame
Motors
Series 15H, 18H, and 22H Keypad Extension Cable
Outside
Mounting
Ap’x
Shpg. Wgt.
Height
Width
Depth
Height
Width
C+
30/(762)
11.5/(292)
12.2/(310)
29.25/(743)
10.5/(267)
160
D+
36/(914)
14.5/(368)
12.2/(310)
35.25/(895)
13.50/(343)
280
Soft Starters &
Dynamic Brakes
Size
DC Motors
and Controls
Dimensions in/(mm)
­299
Farm Duty
Motors
Inverter/Vector Motors & Controls
Series 15H and 18H Dynamic Braking Transistor Assemblies
Definite Purpose
Motors
Dynamic Braking Transistor Assemblies include braking transistor completely assembled and mounted into a NEMA 1
enclosure, to be used with External Dynamic Braking Resistor Assemblies (RGA). Select RGA assembly with matching
minimum OHMS and continuous regenerative power (Watts) capacity to meet load requirements. For use with -EO and
-MO Controls.
Maximum Braking Torque In % Of Motor Rating
Hp
380-480 Vac
550-600 Vac
Unit Handling Motors
300
62%
125%
29%
100%
350
54%
108%
-
87%
400
47%
94%
-
76%
450
41%
84%
-
68%
Cat. No.
RTA4-4
RTA4-2
RTA5-14
RTA5-4
List Price
2,816
3,973
2,354
3,098
Mult. Sym.
E8
E8
E8
E8
Brake Motors
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
­300
Series 15H and 18H Dynamic Braking Resistor Assemblies
Dynamic Braking Resistor Assemblies include braking resistors completely assembled and mounted into a NEMA 1
enclosure. For 20 Hp and above (-EO, -MO Controls), select the braking resistor from the table with the matching
ohms for the RTA selected and adequate continuous watts capacity to meet load requirements. For 1 to 15 Hp (-E,-ER
Controls) select the braking resistor that has correct ohm value for the control and adequate continuous watts capacity
to meet load requirements.
Input
Voltage
Hp
460
300-450
Continuous Rated Watts
Total
Ohms
4800
6400
9600
14200
2
RGA4802
RGA6402
RGA9602
RGA14202
List Price
2,107
5,312
8,525
11,731
Mult. Sym.
EC
EC
EC
EC
Baldor offers a wide variety of plug-in expansion boards for Series 15H Inverters, Series 18H or 22H Vector Drives and
Series 19H or 20H DC Controls. Expansion boards allow the drive to be interfaced with various inputs and outputs.
Each control has the capability to utilize up to two expansion boards. The following list shows boards available. The
matrix shows which boards may be used together in the same control.
Mult. Sym.
Isolated Input/2 Relay Output Accessory Board
Contains 9 Isolated inputs for 90-130VAC. All inputs must be the same voltage.
Also has 2 relay outputs, Form “C”: N.O. and N. C.
Accessory Board mounts in Expansion Board slot but uses wiring harness to connect
to motor control card. Requires control board with onboard 24VDC power supply.
373
E8
EXB003A04
Isolated Input Board
Contains 9 isolated inputs jumper configurable for 10-30 VAC or 10-30 VDC.
All must be the same voltage - one side of all inputs is common. This
board replaces the opto inputs on the main control board.
Uses screw terminals for connection. (Use with Series 15H, 18H and 22H only)
295
E8
EXB003A05
Isolated Input Board
Contains 9 isolated inputs jumper configurable for 90-130 VAC.
All must be the same voltage - one side of all inputs is common. This
board replaces the opto inputs on the main control board.
Uses screw terminals for connection. (Use with Series 15H, 18H and 22H only).
295
E8
EXB004A01
Four Output Relays / 3-15 PSI Pneumatic Interface
Converts 3-15 PSI air pressure to 0-10 VDC or 10-0 VDC (inverted). Also has four
relays, 2 of which are jumper selectable as N.O. or N.C., rated for 230VAC, 5 amps
max and two form “C”. Uses screw terminals for connections. Air hose connects to
1/8” O.D. nipple on board.
542
E8
EXB005A01
Master Pulse Reference / Isolated Pulse Follower–Bi-directional jumper selectable for:
1. Master quadrature pulse reference. Provides 5 volt quadrature A and B channel outputs with complements at
a pulse rate proportional to accel-decel limited speed commands. Phase of B channel is reversed for reverse
direction.
2. Master speed step-direction pulse reference. Provides 5 volt pulse and direction outputs with complements at a
pulse rate proportional to accel-decel limited speed command.
3. Quadrature pulse follower. Provides opto isolated inputs for 5-15 volt quadrature A and B channel input speed
commands and retransmits this input as 5 volt channel A and B outputs with complements at a pulse rate
proportional to accel-decel limited speed command. Motor direction reverses with input channel phase reversal.
4. Speed step and direction pulse follower. Provides opto isolated inputs for 5-15 volt input pulse and direction.
Commands and retransmits these inputs as 5 volt pulse and direction outputs with complements at a pulse rate
proportional to accel-decel limited speed command.
461
E8
567
E8
Brake Motors
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Tachometer Interface
Allows for DC tach input voltage for motor or process feedback Jumper selectable for input voltage with software trim
for 10% tolerance. 250 VDC total maximum input voltage or can be used for one analog input with 16 bits resolution for
±10V and 15 bits resolution for 0-10 VDC input. Uses screw terminals for connection.
DC Motors
and Controls
EXB006A01
Description
Soft Starters &
Dynamic Brakes
Board Number
Unit Handling
Motors
List Price
ACB003A01
Farm Duty
Motors
Series 15H, 18H, 19H, 20H and 22H
Expansion and Accessory Boards
Definite Purpose
Motors
Inverter/Vector Motors & Controls
­301
Farm Duty
Motors
Inverter/Vector Motors & Controls
Series 15H, 18H, 19H, 20H and 22H
Expansion and Accessory Boards continued…
Definite Purpose
Motors
Board No.
Description
EXB007A02
High Resolution Analog Board
Allows one input with up to 16 bits resolution. DC inputs: ± 10V, 0-10V, ± 5V, 0-5V,
with 300 microvolt resolution. Current inputs: 4-20 mA, with 0.6 microamps resolution.
Unit Handling Motors
Input
± 10 V
0 - 10 V
±5V
0-5V
4 - 20 mA
Brake Motors
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
­302
List Price
Mult. Sym.
749
E8
Resolution
16 bit
15 bit
15 bit
14 bit
15 bit
Both the 0-10 V and 4-20 mA inputs may be inverted to 10-0 V and 20-4 mA. Two outputs,
each with ± 10 VDC, 0-10 VDC or 4-20 mA with inverting capability. This replaces the
analog outputs on the main control board. Uses screw terminals for connection.
EXB008A01
Isolated Encoder Feedback Board
This board is recommended for use with motors that do not have an electrically isolated encoder
(Baldor Vector drive motors have isolated encoders). Contains a 0-15 VDC (300mA) isolated power supply to allow use with
5, 12 and 15 VDC encoders by jumper selection. Isolates A, B and index channels with complements. The retransmitted
encoder signals may be configured in two ways with a board level jumper as follows:
1. For 2 channel quadrature output (A and B with complements), set jumper to disable the marker channel (index pulse)
as an input.
2. To use the marker channel (index pulse) as an input, jumper must be set to disable channel B (and compliment)
output. Retransmitted signals will always be 5 VDC differential. Uses screw terminals for connection.
791
E8
EXB010A01
Two analog output/three relay output board.
Provides two isolated analog outputs each with 0-5VDC, 0-10VDC, or 4-20mA capability. Also includes three relay outputs
jumper selectable for N.O. or N.C. rated for 230VAC, 5 amps maximum. Uses screw terminals for connection.
461
E8
EXB012A01
RS232 and RS485 High Speed Serial Communications
Allows Series 15H and 18H controls to be connected to RS232 half and full duplex and isolated RS485 half duplex,230.4K
Baud maximum. Uses DB-9 connector for RS232 and screw terminals for RS485.
295
E8
EXB013A01
DeviceNet Expansion Board
Allows Series 15H and 18H controls to be connected to DeviceNet Communications Bus.
Uses plug in terminals for connection
774
E8
EXB014A01
Profibus DP Expansion Board
Allows Series 15H and 18H controls to be connected to Profibus Communications Bus.
Uses plug in terminals for connection
932
E8
EXB015A01
Modbus plus Expansion Board
Allows Series 15H and 18H controls to be connected to Modbus Communications Bus.
Uses plug in terminals for connection
1,114
E8
Notes on Mounting
Expansion Boards plug into a slot inside the
control. When using one expansion board
either a Group 1 or 2 board will connect by
a connector on the side of the board. When
two expansion boards are used one must
be from Group 1 and one from Group 2.
Accessory Boards can mount into either a
Group 1 or Group 2 slot. When using an
Accessory Board only one other Expansion
Board may be used.
Group 1 Boards
Isolated Input Board
EXB003A04
EXB003A05
Master Pulse Reference/ Isolated Pulse Follower EXB005A01 DC Tachometer Interface EXB006A01
Isolated Encoder Feedback
EXB008A01
Group 2 Boards
Four Output Relays /
3-15 PSI Pneumatic Interface
EXB004A01
High Resolution Analog Board
EXB007A02
Two analog output/three relay outputs
EXB010A01
RS232/RS485 High Speed Serial
Communication
EXB012A01
DeviceNet Communication
EXB013A01
Profibus DP Communication
EXB014A01
Modbus Plus Communication
EXB015A01