DSS Two Stage Package

DSS Two Stage Package
Moniteur
DSS SERIES
Two-Stage “Dribble Control” Package
Ideal Solution for Dribble Control
The Moniteur DSS Two Stage Package is a
complete unit incorporating two solenoid valves and
specially configured limit switches designed for twostage operation. The package mounts to most rotary
pneumatic actuators and allows users to transform
an automated valve into a two stage shutoff
package. The most common applications are:
Valve #2
(2 Way)
> Filling or metering vessels. By being able to
reduce the flow rate at a given point during a
filling operation, it is possible to more accurately
and efficiently fill a vessel.
Valve #1
(3 Way)
Exhaust
Filter
> Flow dampening. With the two stage package,
valves can be partially closed and then
completely closed later. This dramatically
reduces shock to pipes and valves due to water
hammer.
Requirements
> Two voltage sources to power both solenoid valves (#1 and #2).
> Contact logic (2), which may be provided by flow meters, scales, level sensors, or PLCs
> Spring return pneumatic actuator with a clean air source
Features
> Dual flow positions for filling vessels or flow dampening
> Fully adjustable set points allow the user flexibility to determine proper stage switching
> Open / Closed limit switches provide additional valve end point monitoring
> Factory assembled and tested, saving users and assemblers time and money
Ordering Information
Nema
Rating
Package
Model No.*
3-Way Solenoid
( ASCO® )
2-way solenoid
( ASCO® )
Solenoid
Voltage
Solenoid
Body Material
7,9
DSS-AMYB-51B1
EF8320G184
EF8262G93
120 VAC-60Hz
Brass
4,4x
DSS-FMYB-51B1
8320G184
8262G93
120 VAC-60Hz
Brass
7,9
DSS-AMYB-51B3
EF8320G184
EF8262G93
24 VDC
Brass
4,4x
DSS-FMYB-51B3
8320G184
8262G93
24 VDC
Brass
IS
DSS-FMYB-53B5
WBIS8314A300
WBIS8314A300 24VDC / Intrinsically Safe
Brass
* Custom packages to your specifications available on request
Standard Solenoid Valve Porting Configuration
3-Way
Solenoid
8320G184
Cv
0.12
Air
Supply
Port
Air to
Actuator
Port
To 2-way
Exhaust
Port
2-Way
Solenoid
Cv
2
1
3
8262G93
0.15
From 3-way
Exhaust
Port
Filter
Exhaust
Port
IN
OUT
** For larger actuators, solenoid valves with higher flow rates will be required. Contact Moniteur Devices with your requirements.
ASCO is a trademark of the Automatic Switch Company
M O N I T E U R
D E V I C E S
I N C O R P O R A T E D
3 6 C o m m e rc e R o a d , C e d a r G ro v e , N J 0 7 0 0 9 Te l . ( 9 7 3 ) 8 5 7 - 1 6 0 0 F a x ( 9 7 3 ) 8 5 7 - 7 2 8 9
w w w . m o n i t e u r d e v i c e s . c o m
Form DSS1-0609
Moniteur
DSS SERIES
Two-Stage “Dribble Control” Package
Wiring Diagram
MONITEUR DSS POSITION CONTROL
LOGIC SWITCH 3
RED
WHITE
SWITCH 2
NC
C
NO
BLACK
RED
WHITE
GROUND
BLACK
SWITCH 1
NC
C
NO
1 2 3
4 5 6
SWITCH 1
SWITCH 2
7
8
9 10 11 12
Voltage Source V2 (+)
Voltage Source V2 (-)
Voltage Source V1 (+)
Voltage Source V1 (-)
TWO STAGE DRIBBLE CONTROL CONNECTIONS
Installation Procedure / Sequence of Operation
Warning:
Be sure voltage and air pressure supplied match solenoid specifications.
1. Mount limit switch package to the rotary actuator with an appropriate mounting bracket.
2. Connect power and clean filtered air to proper connections (see table on other side for standard
valves). Ensure that all air connections are tight and all electrical connections are secured at their
proper terminal points.
3. With no power to V-1 and V-2, the valve should be in the fully closed position (sequence #1)
4. Energize V-1 and V-2 (sequence #2), solenoid #1 (sol1) will energize allowing the air pressure to
rotate the valve/actuator package to the fully open position.
5. De-energize V-1 and the package will rotate in the opposite direction until the white cam trips switch
3 (blue) and energizes solenoid #2 (sol2). This will stop the valve rotation at the set mid position.
If the mid position is incorrect, estimate approximately how many degrees of rotation the cam
needs to be adjusted. CAUTION - do not adjust cam until the unit is in the fully closed position, as
the unit might rotate unexpectantly if the cam is adjusted under power.
6. Finally, de-energize V-2 (both V-1 and V-2 will be de-energized) and solenoid #2 (sol2) will Deenergize and the valve/actuator package will rotate to the fully closed position. One full cycle has
just been completed. If the mid set position requires adjustment, adjust the package now.
7. Repeat steps 4-6 to verify adjustment and/or re-adjust dribble position.
Caution:
Do not adjust cams while cycling system as the unit might shift unexpectantly
Stage
No.
Flow Condition
Required
Supply Volt. 1
( V-1 )
Supply Volt. 2
( V-2 )
Solenoid #1
( Sol 1 )
Solenoid #2
( Sol 2 )
1
Shut off
De-energize
De-energize
De-energize
De-energize
2
Full Flow
Energize
Energize
Energize
De-energize*
3
Reduced Flow
De-energize
Energize
De-energize
Energize
4
Shut off
De-energize
De-energize
De-energize
De-energize
* Solenoid #2 is de-energized through the limit switch
M O N I T E U R
D E V I C E S
I N C O R P O R A T E D
3 6 C o m m e rc e R o a d , C e d a r G ro v e , N J 0 7 0 0 9 Te l . ( 9 7 3 ) 8 5 7 - 1 6 0 0 F a x ( 9 7 3 ) 8 5 7 - 7 2 8 9
w w w . m o n i t e u r d e v i c e s . c o m