Agilent Technologies | U1270 Series | Agilent U1270 Series Handheld Digital Multimeters

Agilent U1270 Series Handheld Digital Multimeters
Agilent U1270 Series Handheld
Digital Multimeters
Data Sheet
NEW
Features
• OLED display for high
brightness level and wider
viewing angles (up to 160
degrees)1
• Intelligent features:
ZLOW1, 2, Smart Ω1, 2, Low Pass
Filter, Qik-V3
• Visual (Backlight3 and
Symbol1 Alert) and audible
continuity indication in noisy
environments
• Ergonomic shape for better grip
• IP 54 certified – water and
dust resistant
• 30,000-count dual display
• AC + DC capability1, 2
• CAT III 1000 V, CAT IV 600 V
safety rating
• Easy maintenance –
convenient fuse access
• Easy connectivity to PC with
optional IR-USB cable
• Internal memory for data
logging
1. U1273A
2. U1272A
3. U1271A
OLED for more display clarity
The U1273A, the latest addition to
U1270 series, comes with an OLED
display that has outstanding contrast
levels and high brightness levels. The
display also allows wider viewing
angles up to 160 degrees to ensure
that you get the right readings at the
first glance.
Get a better grip on your DMM
The U1270 series is shaped perfectly
to fit in your hand, with or without
gloves on. Its non-slip ergonomic
shape enables you to carry your DMM
and perform measurements on the go
easily. Additionally, the controls are
easy to operate due to the large knob
and buttons.
Improve productivity with
intelligent features
Designed for maximum efficiency
and productivity in industrial settings,
these DMMs offer convenient functions such as ZLOW to eliminate stray
voltages, Smart Ω to minimize false
readings due to leakage current and
Qik-V to determine existence of AC
and/or DC voltages.
Continuity detection in noisy and dark
places is made easy with the U1270
series’ loud beeper and Visual Alert
function that indicates continuity and
improves safety.
When it comes to Variable Frequency
Drive (VFD) troubleshooting, the
U1270 series has Low Pass Filter to
handle the job with ease.
Water and dust resistant
The series’ tightly sealed design
helps protect against water, dust and
damage. Each DMM is IP 54 certified
so that you can carry out test and
measurement with confidence, even
in harsh working conditions.
Key Functions
Low Impedance (ZLOW)
The U1272A and U1273A are dual
input impedance digital multimeters.
The DMM’s high input impedance
is preferred in most electrical
measurements because it would not
load the circuit under test. However,
to obtain accurate measurements
on circuits that may contain stray
voltages, the U1272A and U1273A’s
2 kΩ low impedance function comes
in handy. Stray voltages are usually
found in non-energized electrical
wiring adjacent to powered wires due
to capacitive or inductive coupling
between these wires. When a pair
of test leads is placed between the
open circuit and neutral conductor,
the circuit is then complete and forms
a voltage divider in conjunction with
the input impedance of the multimeter.
High input impedance multimeter is
sensitive enough to measure voltage coupled into the disconnected
conductor, thus giving an inaccurate
indication of a live conductor. The low
impedance function serves to eliminate false readings by dissipating the
stray voltages, thus improves safety
and measurement efficiency during
voltage.
Figure 1. U1272A helps you identify the presence of stray voltage on a disconnected wire running parallel with the wire
powering up the VFD to an industrial motor. The image on the right shows the U1272A in low impedance mode.
2
Key Functions
Low Pass Filter (LPF)
The U1270 series offers a 1 kHz LPF
or Low Pass Filter to provide accurate
Variable Frequency Drive (VFD) output
measurement. This function eliminates
high frequency noise and harmonics.
This ensures the efficiency of your
motor filter as well.
Figure 2. Comparison of voltage output from industrial motor VFD without and with Low Pass Filter functionality.
Smart Ω
The U1272A and U1273A provide an
additional 30 Ohm range for low resistance measurement. This Smart Ω
function is available for ranges of
30 Ohm to 300 kOhm. It enhances
measurement accuracy with offset
compensation by removing residual
DC voltages of up to 1000 mV induced
by ground current and thermal EMF.
This function also enables ‘live’
resistance measurement without
isolating the measurement circuit.
With this, you will be able to obtain
leakage current using the secondary
display.
3
Front and Back Panel Description
OLED display ensures clear
and distinct display readings
Smart Ω 1 removes residual
voltage of up to 1000 mV
Peak detect records
transients as fast as 250 μs
Auto diode 1 automatically
determines diode polarity
Low Pass Filter (LPF)
removes unwanted high
frequency signals
Temperature measurement:
J type thermocouple
–210 to 1200 °C 1, K type
thermocouple –200 to 1732 °C
ZLOW 1 provides both high
and low impedance modes
to eliminate stray voltages
AC + DC 1 capability
Large knob for ease of use
Front panel
1. U1272A and U1273A only
4
Front and Back Panel Description
Hang hole
Probe holder/storage
IR-USB connectivity with
optional IR-USB cable
Slim, ergonomic design
for better grip
Easy fuse and battery
access from battery cover
beneath the stand
Back panel
5
Choose Among These Three Models
Di
U1271A
U1272A
U1273A
30,000
30,000
30,000
Basic Features
Display resolution
Auto/manual ranging
Yes
Yes
Yes
Analog bar graph
Yes
Yes
Yes
Backlight
AC bandwidth
True RMS
Yes
Yes
—
20 kHz
100 kHz
100 kHz
AC
AC + DC
AC + DC
Measurements
Voltage DC
Range
Accuracy
300 mV to 1000 V
0.05% + 2 cnts
30 mV to 1000 V
0.05% + 2 cnts
30 mV to 1000 V
0.05% + 2 cnts
Voltage AC
Range
Accuracy
Bandwidth
300 mV to 1000 V
0.7% + 20 cnts
45 Hz to 20 kHz
30 mV to 1000 V
0.6% + 20 cnts
45 Hz to 100 kHz
30 mV to 1000 V
0.6% + 20 cnts
45 Hz to 100 kHz
Current DC
Range
Accuracy
300 µA to 10 A
0.2% + 5 cnts
300 µA to 10 A
0.2% + 5 cnts
300 µA to 10 A
0.2% + 5 cnts
Current AC
Range
Accuracy
Bandwidth
300 µA to 10 A
0.9% + 25 cnts
45 Hz to 2 kHz
300 µA to 10 A
0.6% + 25 cnts
45 Hz to 2 kHz
300 µA to 10 A
0.6% + 25 cnts
45 Hz to 2 kHz
Resistance
Range
Accuracy
300 Ω to 100 MΩ
0.2 % + 5 cnts
30 Ω to 300 MΩ
0.2% + 5 cnts
30 Ω to 300 MΩ
0.2% + 5 cnts
Frequency
Range
Accuracy
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
Capacitance
Range
Accuracy
10 nF to 10 mF
1% + 2 cnts
10 nF to 10 mF
1% + 2 cnts
10 nF to 10 mF
1% + 2 cnts
Range
K: –200 to 1372 °C
Accuracy
K: –200 to 1372 °C
J: –210 to 1200 °C
1% + 1 °C
1% + 1°C
K: –200 to 1372 °C
J: –210 to 1200 °C
1% + 1 °C
Continuity with beeper
Yes
Yes
Yes
Diode test
Yes
Yes
Yes
Yes
Yes
Yes
Temperature
Data Management
Min/Max Recording
Display Hold
Yes
Yes
Yes
Peak Hold
Yes
Yes
Yes
Manual: 100 points
Interval: 200 points
Manual: 100 points
Interval: 10,000 points
Manual: 100 points
Interval: 10,000 points
Yes
Yes
Yes
IR-USB
IR-USB
IR-USB
Yes
Yes
Yes
Datalogging
Null
PC Connectivity
% scale of 4-20 mA
6
Choose Among These Three Models
Di
U1271A
U1272A
U1273A
—
—
Yes
Special Features
OLED display
Alert in continuity test
Beep + Backlight Alert
Beep + Backlight Alert
Beep + Symbol Alert
Low Pass Filter (LPF)
Yes
Yes
Yes
ZLOW - Low impedance mode
—
Yes
Yes
Smart Ω
—
Yes
Yes
Qik-V
Yes
—
—
CAT III 1000 V,
CAT IV 600 V
CAT III 1000 V,
CAT IV 600 V
CAT III 1000 V,
CAT IV 600 V
Yes
Yes
Yes
4x AAA
4x AAA
4x AAA
Operating temperature
–20 °C to 55 °C,
0 to 80% RH
–20 °C to 55 °C,
0 to 80% RH
–20 °C to 55 °C,
0 to 80% RH
Standard accessories
Standard test leads, test
probes with 4-mm tips,
K-type thermocouple and
adapter, 4x AAA batteries,
Certificate of Calibration,
UK 6 (test report), Quick
Start Guide
Standard test leads, test
probes with 4-mm tips,
K-type thermocouple and
adapter, 4x AAA batteries,
Certificate of Calibration,
UK 6 (test report), Quick
Start Guide
Standard test leads, test
probes with 4-mm tips,
K-type thermocouple and
adapter, 4x AAA batteries,
Certificate of Calibration,
UK 6 (test report), Quick
Start Guide
Safety and Regulatory
Over-voltage safety protection
EN/IEC 61010-1:2001 compliance
General
Battery
7
General Specifications
Display
• U1271A and U1272A: Liquid crystal display (LCD) (with maximum reading of
33,000 counts)
• U1273A: Organic LED (OLED) display (with maximum reading of 33,000 counts)
Power consumption
• U1271A/U1272A: 460 mVA maximum (with backlight enabled)
• U1273A: 180 mVA maximum (with maximum brightness)
Battery type
• 4 × 1.5 V Alkaline battery (ANSI/NEDA 24A or IEC LR03), or
• 4 × 1.5 V Zinc Chloride battery (ANSI/NEDA 24D or IEC R03)
Battery life
• U1271A and U1272A: 300 hours typical (based on new Alkaline batteries for DC
voltage measurement)
• U1273A: 30/45/60 hours typical (based on new Alkaline batteries for DC voltage
measurement at High/Medium/Low brightness, respectively)
• Low battery indicator will flash when the battery voltage drops below 4.4 V
(approximately)
Fuse
• 10 × 35 mm 440 mA/1000 V 30 kA fast-acting fuse
• 10 × 38 mm 11 A/1000 V 30 kA fast-acting fuse
Operating environment
• Operating temperature from –20 to 55 °C, 0 to 80% RH
• Full accuracy up to 80% RH for temperatures up to 30 °C, decreasing linearly to
50% RH at 55 °C
• Altitude up to 2000 meters
• Pollution degree II
Storage compliance
–40 to 70 °C, 0 to 80% RH
Safety compliance
• CAN/CSA-C22.2 No. 61010-1-04
• EN/IEC 61010-1:2001
• ANSI/UL 61010-1:2004
Measurement category
CAT III 1000 V/CAT IV 600 V
Electromagnetic compatibility (EMC)
Commercial limits compliance with EN61326-1
Ingress protection rating
IP-54
Temperature coefficient
0.05 × (specified accuracy) / °C (from –20 to 18 °C, or 28 to 55 °C)
Common Mode Rejection Ratio (CMRR)
> 120 dB at DC, 50/60 Hz ± 0.1% (1 kΩ unbalanced)
Normal Mode Rejection Ration (NMRR)
> 60 dB at 50/60 Hz ± 0.1%
Dimensions (W x H x D)
92 × 207 × 59 mm
Weight
• U1271A: 518 grams (with batteries)
• U1272A: 520 grams (with batteries)
• U1273A: 500 grams (with batteries)
Warranty
• Three years for product
• Three months for product’s accessories
Calibration cycle
One year
Specification Assumptions
• Accuracy is given as ±(% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than
80% RH.
• AC V and AC μA/mA/A specifications are AC coupled, true RMS and are valid from 5% of range to 100% of range.
• The crest factor may be up to 3.0 at full scale except for the 1000 V range where it is 1.5 at full scale.
• For non-sinusoidal waveforms, add (2% reading + 2% full scale) typical, for crest factors up to 3.
• After ZLOW voltage measurements, wait at least 20 minutes for thermal impact to cool before proceeding with any other
measurement.
8
Electrical Specifications
DC specifications for U1271A, U1272A, and U1273A
Function
Voltage1
Resistance2
Range
Resolution
Diode Test
Test current/
Burden voltage
30 mV
0.001 mV
—
0.05 + 20
0.05 + 20
—
300 mV
0.01 mV
0.05 + 5
0.05 + 5
0.05 + 5
—
3V
0.0001 V
0.05 + 5
0.05 + 5
0.05 + 5
—
30 V
0.001 V
0.05 + 2
0.05 + 2
0.05 + 2
—
300 V
0.01 V
0.05 + 2
0.05 + 2
0.05 + 2
—
1000 V
0.1 V
0.05 + 2
0.05 + 2
0.05 + 2
—
ZLOW (low
input
impedance)
enabled,
applicable
for 1000 V
range and
resolution
only
0.1 V
—
1 + 20
1 + 20
—
30 Ω
0.001 Ω
—
0.2 + 10
0.2 + 10
0.65 mA
300 Ω
0.01 Ω
0.2 + 5
0.2 + 5
0.2 + 5
0.65 mA
3 kΩ
0.0001 kΩ
0.2 + 5
0.2 + 5
0.2 + 5
65 µA
30 kΩ
0.001 kΩ
0.2 + 5
0.2 + 5
0.2 + 5
6.5 µA
300 kΩ
0.01 kΩ
0.5 + 5
0.5 + 5
0.5 + 5
0.65 µA
3 MΩ
0.0001 MΩ
0.6 + 5
0.6 + 5
0.6 + 5
93 nA/10 MΩ
30 MΩ
0.001 MΩ
1.2 + 5
1.2 + 5
1.2 + 5
93 nA/10 MΩ
100 MΩ
0.01 MΩ
2.0 +10
—
—
93 nA/10 MΩ
—
2.0 + 10 @ < 100 MΩ
8.0 + 10 @ > 100 MΩ
2.0 + 10 @ < 100 MΩ
8.0 + 10 @ > 100 MΩ
93 nA/10 MΩ
300 MΩ
Current3
Accuracy ± (% of reading +
counts of least significant digit)
U1271A
U1272A
U1273A
0.01 MΩ
300 nS
0.01 nS
1 + 10
1 + 10
1 + 10
93 nA/10 MΩ
300 µA
0.01 µA
0.2 + 5
0.2 + 3
0.2 + 5
< 0.04 V/100 Ω
3000 µA
0.1 µA
0.2 + 5
0.2 + 3
0.2 + 5
< 0.4 V/100 Ω
30 mA
0.001 mA
0.2 + 5
0.2 + 3
0.2 + 5
< 0.08 V/1 Ω
300 mA
0.01 mA
0.2 + 5
0.2 + 3
0.2 + 5
< 1.00 V/1 Ω
3A
0.0001 A
0.3 +10
0.3 +10
0.3 +10
< 0.1 V/0.01 Ω
10 A
0.001 A
0.3 +10
0.3 +10
0.3 +10
< 0.3 V/0.01 Ω
3V
0.0001 V
0.5 + 5
0.5 + 5
0.5 + 5
Approximately
1 to 2 mA
Auto
0.0001 V
—
0.5 + 5
0.5 + 5
Approximately
0.1 to 0.3 mA
4
See notes on next page.
9
Electrical Specifications
Notes for DC specifications (previous page)
1. Notes for voltage specifications:
• The accuracy of the 30 to 300 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads).
• For ZLOW measurements, autoranging is disabled and the multimeter’s range is set to 1000 volts in the manual ranging mode.
2. Notes for resistance specifications:
• Overload protection: 1000 Vrms for short circuits with < 0.3 A current.
• Maximum open voltage is < +3.3 V.
• Built-in buzzer beeps when the resistance measured is less than 25 Ω ± 10 Ω. The multimeter can capture intermittent measurements longer than
1 ms.
• The accuracy of the 300 Ω to 3 kΩ range is specified after the Null function is used to subtract the test lead resistance and thermal effect (by
shorting the test leads).
• For the ranges of 30 MΩ and 100 MΩ, the RH is specified for < 60%.
• The accuracy for ranges < 50 nS is specified after the Null function is used on an open test lead.
• The temperature coefficient of the 100 MΩ and 300 MΩ range is 0.1 × (specified accuracy)/°C (from –20 °C to 18 °C or 28 °C to 55 °C).
3. Notes for current specifications:
• Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.
• Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.
• Specification for 300 mA range: 440 mA continuous.
• Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds
maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
4. Notes for diode specifications:
• Overload protection: 1000 Vrms for short circuits with < 0.3 A current.
• Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased diode or semiconductor
junctions measured between 0.3 V and 0.8 V (0.3 V ≤ reading ≤ 0.8 V).
• Open voltage for diode: < +3.3 V DC.
• Open voltage for Auto diode: < +2.5 V DC and > –1.0 V DC.
10
Electrical Specifications
AC specifications for U1271A
Function
True RMS AC
Voltage1
Range
Resolution
300 mV
0.01 mV
0.7 + 20
1.0 + 25
2.0 + 25
2.0 + 40
3V
0.0001 V
0.7 + 20
1.0 + 25
2.0 + 25
2.0 + 40
30 V
0.001 V
0.7 + 20
1.0 + 25
2.0 + 25
2.0 + 40
300 V
0.01 V
0.7 + 20
1.0 + 25
2.0 + 25
—
1000 V
0.1 V
0.7 + 20
1.0 + 25
—
—
0.7 + 20
1.0 + 25 @ < 200 Hz
5.0 + 25 @ < 440 Hz
—
—
LPF (low pass filter) enabled,
applicable for all voltage
ranges and resolution
Function
True RMS AC
Current2
Accuracy ± (% of reading + counts of least significant digit)
45 Hz to
30 Hz to
1 kHz to
5 kHz to
65 Hz
1 kHz
5 kHz
20 kHz
Range
Resolution
Accuracy ± (% of reading +
counts of least significant digit)
45 Hz to 2 kHz
Burden voltage/Shunt
300 µA
0.01 µA
0.9 + 25
< 0.04 V/100 Ω
3000 µA
0.1 µA
0.9 + 25
< 0.4 V/100 Ω
< 0.08 V/1 Ω
30 mA
0.001 mA
0.9 + 25
300 mA
0.01 mA
0.9 + 25
< 1.00 V/1 Ω
3A
0.0001 A
1.0 + 25
< 0.1 V/0.01 Ω
10 A
0.001 A
1.0 + 25
< 0.3 V/0.01 Ω
1. Notes for voltage specifications:
• Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with < 0.3 A current.
• Input impedance: 10 MΩ (nominal) in parallel with < 100 pF.
2. Notes for current specifications:
• Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.
• Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.
• Specification for 300 mA range: 440 mA continuous.
• Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds
maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
11
Electrical Specifications
AC specifications for U1272A and U1273A
Function
True RMS AC
Voltage1
Function
True RMS AC
Current2
Range
Resolution
Accuracy ± (% of reading + counts of least significant digit)
45 Hz to
20 Hz to
1 kHz to 5 kHz to 20 kHz to
65 Hz
1 kHz
5 kHz
20 kHz
100 kHz
30 mV
0.001 mV
0.6 + 20
0.7 + 25
1.0 + 25
1.0 + 40
3.5 + 40
300 mV
0.01 mV
0.6 + 20
0.7 + 25
1.0 + 25
1.0 + 40
3.5 + 40
3V
0.0001 V
0.6 + 20
1.0 + 25
1.5 + 25
2.0 + 40
3.5 + 40
30 V
0.001 V
0.6 + 20
1.0 + 25
1.5 + 25
2.0 + 40
3.5 + 40
300 V
0.01 V
0.6 + 20
1.0 + 25
1.5 + 25
2.0 + 40
—
1000 V
0.1 V
0.6 + 20
1.0 + 25
1.5 + 25
—
—
LPF (low pass filter) enabled,
applicable for all voltage
ranges and resolution
0.6 + 20
1.0 + 25 @ < 200 Hz
5.0 + 25 @ < 440 Hz
—
—
—
ZLOW 1000 V
2.0 + 40
2 + 40 @ < 440 Hz
—
—
—
Range
Resolution
Accuracy ± (% of reading +
counts of least significant digit)
45 Hz to 65 Hz
20 Hz to 2 kHz
Burden voltage/Shunt
300 µA
0.01 µA
0.6 + 25
0.9 + 25
< 0.04 V/100 Ω
3000 µA
0.1 µA
0.6 + 25
0.9 + 25
< 0.4 V/100 Ω
30 mA
0.001 mA
0.6 + 25
0.9 + 25
< 0.08 V/1 Ω
300 mA
0.01 mA
0.6 + 25
0.9 + 25
< 1.00 V/1 Ω
3A
0.0001 A
0.8 + 25
1.0 + 25
< 0.1 V/0.01 Ω
10 A
0.001 A
0.8 + 25
1.0 + 25
< 0.3 V/0.01 Ω
1. Notes for voltage specifications:
• Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with < 0.3 A current.
• Input impedance: 10 MΩ (nominal) in parallel with < 100 pF.
• ZLOW impedance: 2 kΩ (nominal).
• The input signal is lower than the product of 20,000,000 V×Hz.
• For 20 to 100 kHz accuracy: Three counts of the LSD per kHz of additional error is to be added for frequencies > 20 kHz and signal inputs < 10%
of range.
2. Notes for current specifications:
• Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.
• Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.
• Specification for 300 mA range: 440 mA continuous.
• Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds
maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
12
Electrical Specifications
AC + DC specifications for U1272A and U1273A
Function
True RMS
AC + DC
Voltage1
Function
True RMS
AC + DC
Current2
Range
Resolution
Accuracy ± (% of reading + counts of least significant digit)
45 Hz to
20 Hz to
1 kHz to
5 kHz to 20 kHz to
65 Hz
1 kHz
5 kHz
20 kHz
100 kHz
30 mV
0.001 mV
0.7 + 40
0.8 + 45
1.1 + 45
1.1 + 60
3.6 + 60
300 mV
0.01 mV
0.7 + 25
0.8 + 30
1.1 + 30
1.1 + 45
3.6 + 45
3V
0.0001 V
0.7 + 25
1.1 + 30
1.6 + 30
2.1 + 45
3.6 + 45
30 V
0.001 V
0.7 + 25
1.1 + 30
1.6 + 30
2.1 + 45
3.6 + 45
300 V
0.01 V
0.7 + 25
1.1 + 30
1.6 + 30
2.1 + 45
—
1000 V
0.1 V
0.7 + 25
1.1 + 30
1.6 + 30
—
—
Accuracy ± (% of reading +
counts of least significant digit)
45 Hz to 65 Hz
20 Hz to 2 kHz
Range
Resolution
Burden voltage/Shunt
300 µA
0.01 µA
0.8 + 30
1.1 + 30
< 0.04 V/100 Ω
3000 µA
0.1 µA
0.8 + 30
1.1 + 30
< 0.4 V/100 Ω
30 mA
0.001 mA
0.8 + 30
1.1 + 30
< 0.08 V/1 Ω
300 mA
0.01 mA
0.8 + 30
1.1 + 30
< 1.00 V/1 Ω
3A
0.0001 A
0.9 + 35
1.3 + 35
< 0.1 V/0.01 Ω
10 A
0.001 A
0.9 + 35
1.3 + 35
< 0.3 V/0.01 Ω
1. Notes for voltage specifications:
• Overload protection: 1000 Vrms. For millivolt measurements, 1000 Vrms for short circuits with < 0.3 A current.
• Input impedance: 10 MΩ (nominal) in parallel with < 100 pF.
• For 20 to 100 kHz accuracy: Three counts of the LSD per kHz of additional error is to be added for frequencies > 20 kHz and signal inputs < 10%
of range.
2. Notes for current specifications:
• Overload protection for 300 μA to 300 mA range: 0.44 A/1000 V; 10 × 35 mm 30 kA fast-acting fuse.
• Overload protection for 3 A to 10 A range: 11 A/1000 V; 10 × 38 mm 30 kA fast-acting fuse.
• Specification for 300 mA range: 440 mA continuous.
• Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 to 20 A for 30 seconds
maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low
current measurements.
13
Electrical Specifications
Temperature specifications1 - 6
Thermocouple type
K
J
Accuracy ± (% of reading +
counts of least significant digit)
U1271A
U1272A
U1273A
Range
Resolution
–200 to 1372 °C
0.1 °C
1% + 1 °C
1% + 1 °C
1% + 1 °C
–328 to 2502 °F
0.1 °F
1% + 1.8 °F
1% + 1.8 °F
1% + 1.8 °F
–210 to 1200 °C
0.1 °C
—
1% + 1 °C
1% + 1 °C
–346 to 2192 °F
0.1 °F
—
1% + 1.8 °F
1% + 1.8 °F
1. The specifications above is specified after 60 minutes of warm-up time.
2. The accuracy does not include the tolerance of the thermocouple probe.
3. Do not allow the temperature sensor to contact a surface that is energized above 30 Vrms or 60 V DC. Such voltages pose a shock hazard.
4. Ensure that the ambient temperature is stable within ±1 ºC and that the Null function is used to reduce the test lead’s thermal effect and temperature
offset. Before using Null function, set the multimeter to measure temperature without ambient compensation (°C) and keep the thermocouple probe
as close to the multimeter as possible (avoid contact with any surface that has a different temperature from the ambient temperature).
5. When measuring temperature with respect to any temperature calibrator, try to set both the calibrator and multimeter with an external reference
(without internal ambient compensation). If both the calibrator and multimeter are set with internal reference (with internal ambient compensation),
some deviations may show between the readings of the calibrator and multimeter, due to differences in ambient compensation between the
calibrator and multimeter. Keeping the multimeter close to the output terminal of calibrator will help reduce the deviation.
6. The temperature calculation is specified according to the safety standards of EN/IEC-60548-1 and NIST175.
Capacitance specifications7, 8
Range
Resolution
Accuracy ± (% of reading +
counts of least significant digit)
U1271A
U1272A
U1273A
10 nF
0.001 nF
1+5
1+5
1+5
100 nF
0.01 nF
1+2
1+2
1+2
1000 nF
0.1 nF
1+2
1+2
1+2
10 μF
0.001 μF
1+2
1+2
1+2
100 μF
0.01 μF
1+2
1+2
1+2
1000 μF
0.1 μF
1+2
1+2
1+2
10 mF
0.001 mF
1+2
1+2
1+2
7. Overload protection: 1000 Vrms for short circuits with < 0.3 A current.
8. The accuracy for all ranges is specified based on a film capacitor or better, and after the Null function is used to subtract the test lead resistance and
thermal effect (by shorting the test leads).
14
Electrical Specifications
Frequency specifications1, 2
Range
Resolution
Accuracy ± (% of reading +
counts of least significant digit)
99.999 Hz
0.001 Hz
0.02 + 5
999.99 Hz
0.01 Hz
0.005 + 5
9.9999 kHz
0.1 Hz
0.005 + 5
99.999 kHz
1 Hz
0.005 + 5
999.99 kHz
0.01 kHz
0.005 + 5
> 1 MHz
0.1 kHz
0.005 + 5 @ < 1 MHz
10 mF
0.001 mF
1+2
Minimum input frequency
0.5 Hz
1. Overload protection: 1000 V; input signal is < 20,000,000 V × Hz (product of voltage and frequency).
2. The frequency measurement is susceptible to error when measuring low-voltage, low-frequency signals. Shielding inputs from external noise pickup is
critical for minimizing measurement errors. Turning on the low pass filter may help you to filter out the noise and achieve a stable reading.
Duty Cycle3
Mode
Range
Accuracy at full scale
DC coupling
99.99%
0.3 % per kHz + 0.3 %
AC coupling
99.99%
0.3 % per kHz + 0.3 %
3. Notes for duty cycle specifications:
• The accuracy for duty cycle and pulse width measurements is based on a 3 V square wave input to the DC 3 V range. For AC couplings, the duty
cycle range can be measured within the range of 10% to 90% for signal frequencies > 20 Hz.
• The range of the duty cycle is determined by the frequency of the signal: {10 μs × frequency × 100%} to {[1 – (10 μs × frequency)] × 100%}.
• The pulse width (positive or negative) must be > 10 μs. The range of the pulse width is determined by the frequency of the signal.
Pulse Width4
Range
Resolution
Accuracy at full scale
999.99 ms
0.01 ms
(duty cycle accuracy/frequency) + 0.01 ms
2000.0 ms
0.1 ms
(duty cycle accuracy/frequency) + 0.1 ms
4. Notes for pulse width specifications:
• The accuracy for duty cycle and pulse width measurements is based on a 3 V square wave input to the DC 3 V range.
• The pulse width (positive or negative) must be > 10 μs. The range of the pulse width is determined by the frequency of the signal.
15
Electrical Specifications
U1271A and U1272A frequency sensitivity for voltage measurements1, 2, 3
Minimum sensitivity (RMS sine wave)
15 Hz to
0.5 Hz to
Up to
100 kHz
200 kHz
1 MHz
Input range
30 mV
300 mV
3V
30 V
3 mV
6 mV
0.12 V
0.6 V
3 mV
8 mV
0.2 V
0.8 V
—
40 mV
0.4 V
2.6 V
300 V
6V
8 V @ < 100 kHz
1000 V
50 V
50 V @ < 100 kHz
Trigger level for DC coupling
0.5 Hz to 200 kHz
U1271A
U1272A
—
10 mV
0.15 V
1.5 V
5 mV
15 mV
0.15 V
1.5 V
—
9 V @ < 100 kHz
9 V @ < 100 kHz
—
90 V @ < 100 kHz
90 V @ < 100 kHz
1. Maximum input for specified accuracy, refer to “AC specifications” on page 11.
2. 30 mV range applicable for U1272A only.
3. 200 kHz to 1 MHz range applicable for U1272A only.
U1273A sensitivity for voltage measurements4
Input range
Maximum input for specified
accuracy, refer to AC voltage
30 mV
300 mV
3V
30 V
Frequency sensitivity and trigger level
Minimum sensitivity (RMS sine wave) Trigger level for DC coupling
15 Hz to
0.5 Hz to
Up to
0.5 Hz to 200 kHz
100 kHz
200 kHz
1 MHz
3 mV
7 mV
0.12 V
0.8 V
3 mV
8 mV
0.12 V
0.8 V
—
38 mV
0.48 V
3.5 V
5 mV
15 mV
0.15 V
1.5 V
300 V
6.7 V
8 V < 100 kHz
—
11 V < 100 kHz
1000 V
67 V
67 V < 100 kHz
—
110 V < 100 kHz
4. Maximum input for specified accuracy, refer to “AC specifications” on page 11.
Frequency sensitivity for current measurements5
Input range
300 µA
3000 µA
30 mA
300 mA
3A
10 A
Minimum sensitivity (RMS sine wave)
2 Hz to 30 kHz
U1271A/U1272A
U1273A
100 µA
70 µA
1.2 mA
12 mA
0.12 A
1.2 A
70 μA
120 μA
1.2 mA
12 mA
0.12 A
1.2 A
5. Maximum input for specified accuracy, refer to “AC specifications” on page 11.
Peak hold
Signal width
Accuracy for DC Voltage and Current
Single event >1 ms
Repetitive >250 µs
Specified accuracy + 400
Specified accuracy + 1000
16
Electrical Specifications
Decibel (dB) for U1272A and U1273A1, 2, 3
dB base
Reference
Default reference
1 mW (dBm)
1 to 9999 Ω
50 Ω
1 V (dBV)
1V
1V
1. The reading of dBm is indicated in decibels of power above or below 1 mW, or decibels of voltage above or below 1 V. The formula is calculated
according to the voltage measurement and specified reference impedance. Its accuracy is depended on the accuracy of the voltage measurement.
See Decibel (dBV) accuracy table below.
2. Auto-ranging mode is used.
3. The bandwidth is according to voltage measurement.
Decibel (dBV) accuracy
dBV range
Range
Accuracy
20 Hz to 1 Hz to 5 kHz to
1 kHz
5 kHz
20 kHz
Minimum
Maximum
45 Hz to
65 Hz
20 Hz to
100 kHz
30 mV
–56.48
–30.46
0.06
0.07
0.09
0.1
0.32
300 mV
–36.48
–10.46
0.06
0.07
0.09
0.1
0.32
3V
–16.48
+9.54
0.06
0.09
0.14
0.19
0.32
30 V
+3.52
+29.54
0.06
0.09
0.14
0.19
0.32
300 V
+23.52
+49.54
0.06
0.09
0.14
0.19
—
1000 V
+33.98
+60
0.06
0.09
0.14
—
—
Measurement rate (approximate)
Function
U1271A
Times/second
U1272A/U1273A
ACV
7
7
DCV
7
7
Ω
14
14
Ω with offset compensation
-
3
Diode
14
14
Auto Diode
-
3
Capacitance
4 (< 100 µF)
4 (< 100 µF)
DCA
7
7
ACA
7
7
Temperature
7
7
Frequency
2 (> 10 Hz)
2 (> 10 Hz)
Duty cycle
1 (> 10 Hz)
1 (> 10 Hz)
Pulse width
1 (> 10 Hz)
1 (> 10 Hz)
17
Ordering Information
U1271A
U1272A
U1273A
Standard shipped accessories
Standard test leads, test probes with 4-mm tips, K-type thermocouple and adapter, 4x AAA batteries, Certificate of Calibration, UK 6
(test report), Quick Start Guide
Optional accessories
Measuring accessories (non-temperature)
U1161A
Extended test
lead kit
Includes two test leads (red and black), two test probes, mediumsized alligator clips and 4-mm banana plugs.
• Test leads: CAT II 1000 V, 15 A
• Test probes: CAT III 1000 V, 15 A
• Medium-sized alligator clips: CAT III 1000 V/CAT IV 600 V, 10 A
• 4-mm banana plugs: CAT II 600 V, 10 A
U1162A
Alligator clips
• One pair of insulated alligator clips (red and black).
Recommended for use with Agilent standard test leads.
• Rated CAT III 1000 V, 10 A
U1163A
SMT grabbers
• One pair of SMT grabbers (red and black). Recommended for use
with Agilent standard test leads.
• Rated CAT II 300 V, 3 A
U1164A
Fine-tip test
probes
• One pair of fine-tip test probes (red and black). Recommended for
use with Agilent standard test leads.
• Rated CAT II 300 V, 3 A
U1168A
Standard test
lead kit
Includes two test leads (red and black), 4-mm test probes, alligator
clips, fine-tip test probes, SMT grabbers and mini grabber (black).
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (19-mm tips): CAT II 1000 V, 15 A
• Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
(highly recommended for CAT IV environment)
• Alligator clips: CAT III 1000 V, 10 A, CAT IV 600 V, 10 A
• Fine-tip test probes: CAT II 300 V, 3 A
• SMT grabber: CAT II 300 V, 3 A
• Mini grabber: CAT II 300 V, 3 A
U1583B
AC current clamp
• Dual range: 40 A and 400 A
• Rated CAT III 600 V
• BNC-to-banana-plug adapter provided for use with DMMs
18
Ordering Information
Optional accessories
Measuring accessories (temperature)
U1180A
Thermocouple
adapter+lead kit,
J and K types
Includes thermocouple adapter, thermocouple bead J-type and
thermocouple bead K-type.
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C
• T/C bead K-type: –20 °C to 200 °C
U1181A
Immersion
temperature probe
• Type-K T/C for use in oil and other liquids
• Measurement range: –50 °C to 700 ºC
• Includes adapter U1184A for connection to DMM
U1182A
Industrial surface
temperature probe
• Type-K T/C for use on still surfaces
• Measurement range: –50 ºC to 400 ºC
• Includes adapter U1184A for connection to DMM
U1183A
Air temperature
probe
• Type-K T/C for use in air and non-caustic gas
• Measurement range: –50 ºC to 800 ºC
• Includes adapter U1184A for connection to DMM
U1184A
Temperature probe
adapter
• Mini-connector-to-banana-plug adapter for use with DMM
U1185A
J-type thermocouple
and adapter
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C
U1186A
K-type
thermocouple and
adapter
• T/C adapter J/K-type
• T/C bead J-type: –20 °C to 200 °C
19
Ordering Information
Optional accessories
Cable
U1173A
IR-to-USB cable
• For remote control and data logging to PC
• Maximum baud rate: 19,200 bits per second
U1174A
Soft carrying case
The convenient way to carry your DMM and essential accessories
• Dimension: 9 inches (H) x 5 inches (W) x 3 inches (D)
Hanging kit
U1171A
Magnetic hanging
kit
For fastening the DMM to a steel surface so both hands are free
Probe Clip Light
U1176A
LED Probe Clip Light
• 3 inches in length
• To be clipped onto test probes to increase visibility
• Comes with one AAA battery
20
www.agilent.com
www.agilent.com/find/handhelddmm
For more information on Agilent
Technologies’ products, applications or
services, please contact your local Agilent
office. The complete list is available at:
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
www.axiestandard.org
AdvancedTCA® Extensions for
Instrumentation and Test (AXIe) is
an open standard that extends the
AdvancedTCA for general purpose
and semiconductor test. Agilent
is a founding member of the AXIe
consortium.
www.lxistandard.org
LAN eXtensions for Instruments puts
the power of Ethernet and the Web
inside your test systems. Agilent
is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation
(PXI) modular instrumentation
delivers a rugged, PC-based highperformance measurement and
automation system.
Agilent Channel Partners
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s
measurement expertise and product
breadth, combined with channel
partner convenience.
Agilent Advantage Services is committed
to your success throughout your equipment’s lifetime. To keep you competitive,
we continually invest in tools and
processes that speed up calibration and
repair and reduce your cost of ownership.
You can also use Infoline Web Services
to manage equipment and services more
effectively. By sharing our measurement
and service expertise, we help you create
the products that change our world.
www.agilent.com/find/advantageservices
www.agilent.com/quality
www.agilent.com/find/contactus
Americas
Canada
Brazil Mexico
United States
(877) 894 4414
(11) 4197 3500
01800 5064 800
(800) 829 4444
Asia Pacific
Australia 1 800 629 485
China
800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan
0120 (421) 345
Korea
080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan
0800 047 866
Other AP Countries (65) 375 8100
Europe & Middle East
Belgium 32 (0) 2 404 93 40
Denmark
45 70 13 15 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
49 (0) 7031 464 6333
Ireland
1890 924 204
Israel972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
United Kingdom 44 (0) 131 452 0200
For other unlisted countries:
www.agilent.com/find/contactus
Revised: June 8, 2011
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2010, 2011
Published in USA, September 2, 2011
5990-6425EN
Agilent U1177A
IR-to-Bluetooth Adapter
Data Sheet
Features
•
Enables Bluetooth® connection to Agilent handheld
digital multimeters
•
Easy to install by attaching
to Infrared (IR) port located
at the back of Agilent handheld digital multimeters
•
Compatible with Agilent
U1230 series, U1240 series,
U1250 series and U1270
series handheld digital
multimeters
•
Operated by two 1.5 V AAA
batteries
The Bluetooth® word mark and logos are
registered trademark owned by Bluetooth
SIG, Inc and any use of such marks by
Agilent Technologies, Inc. is under license.
Other trademark and trade names are those
of their respective owners.
Agilent U1177A Infrared (IR)-to-Bluetooth® adapter offers wireless
remote connectivity solution via Bluetooth® connection simply by
attaching the adapter to the IR port of an Agilent handheld digital
multimeter. The wireless remote connectivity is set up when an
Agilent handheld digital multimeter is connected to U1177A and an
Android device (tablet or smart phone) with the installed software.
Every U1177A also has a unique Media Access Control (MAC)
address. User can quickly and easily scan for the right U1177A using
their Android device and pair up with the U1177A.
Figure 1. Agilent wireless remote connectivity solution
Take a closer look
Low battery indication:
Red LED flashing
Bluetooth® disconnected:
Green LED flashing
Bluetooth® connected:
Green solid LED
Bluetooth® power off:
LED off
ON/OFF/Setup
slide switch
Figure 2. The U1177A as illustrated
2
Perform data logging with multimeters – wirelessly!
Data logging is an important function for industrial users to capture data
streams or plotting trending graphs. These data and graphs are used for analysis
to identify intermittent behavior or detect drifts. Agilent Mobile Logger is the
free Android application software that logs data and provides trending graphs
from Agilent handheld digital multimeters. Agilent Mobile Logger offers an array
of extended functions such as sending e-mail or Short Message Service (SMS)
automatically, and pan and zoom function via the Android device’s touch screen.
Alternatively, data logging and monitoring activities can also be performed at the
comfort of one’s Personal Computer (PC) via a downloadable Agilent GUI data
logger software.
Notes:
1. Agilent Mobile Meter and Agilent Mobile Logger can be downloaded from www.agilent.com/
find/hh-Android or from Android Market (https://market.android.com/)
2. Agilent GUI Data Logger Software can be www.agilent.com/find/hh-logger
Figure 3. Data logging with Agilent
Mobile Logger software.
Perform up to three multimeter measurements at the same time
with Agilent Mobile Meter
Agilent Mobile Meter is a free Android application software that allows an
Android device to connect, control and perform up to 3 multimeter measurements. Without the need to be physically present at various points, users can
now extend their reach to two or three places. This solution allows you to make
measurements from a safe distance, eliminates the need to walk back-and-forth
between measure target and control points, and monitors multiple measurements simultaneously. Achieve higher work productivity when you use the
U1177A with your Agilent handheld digital multimeters.
Figure 4. Up to three multimeters
measurements with the Agilent
Mobile Meter
Figure 5. Make measurements with the Agilent Mobile Meter via an Android smart phone
3
Specifications
Product characteristics
Description
Radio specification
•
•
•
•
Operating environment
Operating temperature from –20 to 55 °C
Storage environment
Storage temperature from –40 to 70 °C
Relative humidity (R.H.)
Relative humidity up to 95% at 40 °C (non-condensing)
Power consumption
Maximum 130 mVA for two 1.5 V AAA batteries
Battery life
30 hours typical (based on continuous data transfer)
Battery type
Alkaline 24 A (ANSI/NEDA) and LR03 (IEC), or Zinc Chloride 24 D (ANSI/NEDA)
and R03 (IEC)
Dimension (W x H x L)
39.0 × 71.0 × 37.0 mm
Weight
60 g with batteries
Warranty
Three months
Bluetooth
"Bluetooth" Version 2.1 + EDR compliant, SPP profile, Class 2 device
(with 10 metres connection range)
Safety
Frequency: 2402 MHz ~ 2480 MHz
Antenna Power: 1 mW or less
Number of Channels: 79
Modulation: GFSK / PSK
The U1177A complies with the requirements of the following safety and regulation
standards:
• FCC Part15C (Certification) (15.209, 15.247) FCC ID: ZKMAGILENT-U1177A
• FCC Part15B (DoC) (15.109)
• RSS–210 Issue 8:2010 IC: 6310A–U1177A
• ICES–003 Issue 4:2004
• EN 300 328 V1.7.1:2008
• EN 301 489–1V1.8.1:2008/–17 V2.11:2009
• EN 55022:2006+A1:2007/EN55024:1998+A1:2001+A2:2003
• EN 50371:2002
• EN 60950–1:2006/A11:2009/A1:2010
• Complies with IDA Standards (DB 102425)
• India Equipment Type Approval (ETA) Certificate No: 1424/2011/WRLO
• COFETEL Certificate No: RCPAGU111-1066, registered under Agilent Technologies
Mexico S de RL de CV
"This telecommunication equipment conforms NTC technical requirement"
Standard shipped items:
• Two 1.5 V AAA batteries
• Operating instructions
4
www.agilent.com
www.agilent.com/find/U1177A
For more information on Agilent
Technologies’ products, applications or
services, please contact your local Agilent
office. The complete list is available at:
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
www.axiestandard.org
AdvancedTCA® Extensions for
Instrumentation and Test (AXIe) is
an open standard that extends the
AdvancedTCA for general purpose
and semiconductor test. Agilent
is a founding member of the AXIe
consortium.
www.lxistandard.org
LAN eXtensions for Instruments puts
the power of Ethernet and the Web
inside your test systems. Agilent
is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation
(PXI) modular instrumentation
delivers a rugged, PC-based highperformance measurement and
automation system.
Agilent Channel Partners
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s
measurement expertise and product
breadth, combined with channel
partner convenience.
Agilent Advantage Services is committed
to your success throughout your equipment’s lifetime. To keep you competitive,
we continually invest in tools and
processes that speed up calibration and
repair and reduce your cost of ownership.
You can also use Infoline Web Services
to manage equipment and services more
effectively. By sharing our measurement
and service expertise, we help you create
the products that change our world.
www.agilent.com/find/advantageservices
www.agilent.com/quality
www.agilent.com/find/contactus
Americas
Canada
Brazil Mexico
United States
(877) 894 4414
(11) 4197 3600
01800 5064 800
(800) 829 4444
Asia Pacific
Australia 1 800 629 485
China
800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan
0120 (421) 345
Korea
080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan
0800 047 866
Other AP Countries (65) 375 8100
Europe & Middle East
Belgium 32 (0) 2 404 93 40
Denmark
45 45 80 12 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
49 (0) 7031 464 6333
Ireland
1890 924 204
Israel972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
United Kingdom 44 (0) 118 927 6201
For other unlisted countries:
www.agilent.com/find/contactus
Revised: January 6, 2012
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2012
Published in USA, February 2, 2012
5990-9531EN