advertisement
▼
Scroll to page 2
of
13
QO® Load Centers Indoor-1Ø, Main Lug Class 736, 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W Load Centers, 120/240 Vac, UL Listed Main Lugs (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI, and QO-PL branch circuit breakers from pages 1-2 and 1-3) I N D O O R Max. Tandem Circuit Breakers Load Center Box and Interior $ Price (Interior, Box and Cover) Cat. No. Indoor Cover with Door (Order Separately) $ Price Flush Cat. No. Main Wire Size Equipment Ground Bar AWG/kcmil Kit (Order Separately) Box No. See Page 1-17 $ Price Al Cu Cat. No. $ Price Surface Cat. No. Fixed Mains—Factory-Installed Main Lugs—10 kA Short Circuit Current Ratingb 30 A 2 2 0 41.70 QO2L30Scd 41.70 12–10 14–10 PK3GTA1 11.40 70 A 2 4 2 69.00 QO24L70F/Sef 69.00 Cover Included—Without Door 12–3 14–4 PK4GTA 10.80 87.00 QO612L100F/Seg 87.00 8–1 PK7GTA 11.70 6 12 6 90.00 QO612L100DF/Seg 90.00 Cover Included—With Door 8–1 PK7GTA 11.70 100 A 131.00 QO816L100F/Seg 131.00 Cover Included—Without Door 8 16 8 8–1 PK7GTA 11.70 143.00 QO816L100DF/Seg 143.00 Cover Included—With Door 6 12 6 111.00 QO612L100DFCU/SCUegh 111.00 Cover Included—With Door 8–1 PK7GTA 11.70 100 A 8 16 8 174.00 QO816L100DFCU/SCUegh 174.00 Cover Included—With Door 8–1 PK7GTA 11.70 125 A 4 8 4 93.00 QO148L125GF/Sei 93.00 Cover Included—Without Door 12–2/0 14–2/0 PK7GTAl Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Cu Busbj 12 12 0 196.70 QO112L125G 159.00 QOC16UF QOC16US 37.70 PK9GTAl 12 24 12 235.70 QO11224L125G 198.00 QOC16UF QOC16US 37.70 PK15GTAl 16 16 0 255.70 QO116L125G 218.00 QOC24UF QOC24US 37.70 PK12GTAl 16 24 8 300.70 QO11624L125G 263.00 QOC24UF QOC24US 37.70 PK15GTAl 125 A 6–2/0 20 20 0 271.70 QO120L125G 234.00 QOC24UF QOC24US 37.70 PK15GTAl 20 24 4 370.70 QO12024L125G 333.00 QOC24UF QOC24US 37.70 PK15GTAl 24 24 0 381.70 QO124L125G 344.00 QOC24UF QOC24US 37.70 PK15GTAl 32 32 0 434.60 QO132L125G 395.00 QOC32UF Use Flush 39.60 PK23GTA, LK100ANl Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating , QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Cu Busbj 20 30 10 419.00 QO12030L150G 332.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 24 24 0 431.00 QO124L150G 344.00 QOC30UF QOC30US 87.00 6–250 PK15GTAl 150 A 30 30 0 437.00 QO130L150G 350.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 12 12 0 353.00 QO112L200G 266.00 QOC30UF QOC30US 87.00 PK15GTAl 24 36 12 819.00 QO12436L200TFTk 732.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl 30 30 0 494.00 QO130L200G 407.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl 200 A 30 40 10 554.00 QO13040L200G 467.00 QOC30UF QOC30US 87.00 6–250 PK23GTA, LK100ANl 40 40 0 746.00 QO140L200G 659.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl 40 60 20 944.00 QO14060L200G 857.00 QOC40UF QOC40US 87.00 (2) PK15GTAl New! 42 52 10 921.00 QO14252L200G 810.00 QOC42UF QOC42US 111.00 (2) PK15GTAl 225 A 42 42 0 828.00 QO142L225G 717.00 QOC42UF QOC42US 111.00 6–300 PK23GTA, LK100ANl Fixed Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Ratingbj QONQ30LS400 (Int) 1080.00 (1) 1/0–750 400 A 30 30 0 1641.00 NC50NQVF NC50NQVS 486.00 33.80 MH50 (box)o 75.00 or (2) 1/0–300 PK27GTAn or QONQ42LS400 (Int)m 1185.00 (1) 1/0–750 PK15GTA6 53.00 400 A 42 42 0 1746.00 NC50NQVF NC50NQVS 486.00 MH50 (box) 75.00 or (2) 1/0–300 Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c Will not accept QO-EPD or Qwik-Gard® QO-GFI or QO-AFI circuit breakers. d Mains rated 25 A when Al wire is used. e Order F for flush device or S for surface device. f Use 10 AWG maximum size wire for GFI and AFI circuit breakers. g 70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker. h CU indicates copper bus. i Copper bus. j UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. k Supplied with feed-thru lugs. l Factory-included. m Interior only, order box separately. n PK27GTA includes a 6–2/0 AWG Al/Cu lug. o PE1A Discount Schedule. QO120L125G 1 2 4 4 4 LOAD CENTERS Mains Max. 1P Rating Spaces Circuitsa 4 4 21 6 6 7 7 7 7 7 8 1 Table 1.16: 9 9 9 9 10 9 9 10 10 11 11 15 15 QO816L100F or S without cover Main Circuit Breaker Kits Table 1.17: Field-Installed Main Circuit Breaker (Use with Convertible Load Centers Only) QOM1 Frame Size QOM1 Frame Size 50–125 Amperes p q r QOM2 Frame Size 100–225 Amperes © 2009 Schneider Electric All Rights Reserved s QOM2 Frame Sizes 22 k AIRq Lug Wire Sizer Lug Wire Sizer Main Circuit Main Circuit AWG/kcmil AWG/kcmil $ Price $ Price Breaker Breaker 50 A 100–125 QOM50VH 140.00 100 A 150–225 QOM2100VH 468.00 60 A 100–125 QOM60VH 140.00 125 A 150–225 QOM2125VH 468.00 70 A 100–125 QOM70VH 140.00 150 A 150–225 QOM2150VH 468.00 4–300 Al or Cu 80 A 100–125 QOM80VH 201.00 175 A 200–225 QOM2175VH 468.00 12–2/0 Al or Cu 90 A 100–125 QOM90VH 201.00 200 A 200–225 QOM2200VH 468.00 100 A 100–125 QOM100VH 201.00 225 A 225 QOM2225VH 468.00 110 A 125 QOM110VH 468.00 125 A 125 QOM125VH 468.00 Do not exceed the load center mains rating. 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00. Main Circuit Breaker Ratingp Convertible Load Center Mains Rating 22 k AIRq DE3A PE1A Main Circuit Breaker Ratingp Discount Schedule Convertible Load Center Mains Rating 1-5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® Load Centers Indoor, 1Ø Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 1Ø3W—120/240 Vac—UL Listed Table 1.18: Mains Rating LOAD CENTERS I N D O O R Indoor Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL Branch Circuit Breakers from pages 1-2 and 1-3.) Spaces Max. Single Pole Circuitsa Max. Tandem Circuit Breakers $ Price (Interior, Box and Cover) Indoor Cover with Door (Order Separately) Load Center Box and Interior Cat. No. $ Price Flush Cat. No. Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating, Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),b QOM1 Main Circuit Breaker Frame Size—Copper Bus 12 12 0 339.70 QO112M100 302.00 QOC12UF 16 16 0 379.70 QO116M100 342.00 QOC20U100F 100 A 20 20 0 433.70 QO120M100 396.00 QOC20U100F 24 24 0 553.70 QO124M100 516.00 QOC24UF 32 32 0 726.70 QO132M100 689.00 QOC32UF 24 24 0 819.70 QO124M125 782.00 QOC24UF 125 A 32 32 0 1041.60 QO132M125 1002.00 QOC32UF Convertible Mains —Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5) b QOM2 Main Circuit Breaker Frame Size—Copper Bus 20 30 10 821.00 QO12030M150 734.00 QOC30UF 24 24 0 849.00 QO124M150 762.00 QOC30UF 150 A 30 30 0 854.00 QO130M150 767.00 QOC30UF 32 32 0 969.00 QO132M150 882.00 QOC40UF 20 40 20 821.00 QO12040M200 734.00 QOC30UF 24 24 0 866.00 QO124M200 779.00 QOC30UF Surface Cat. No. $ Price QOC12US QOC20U100S QOC20U100S QOC24US Use Flush QOC24US Use Flush 37.70 37.70 37.70 37.70 37.70 37.70 39.60 QOC30US QOC30US QOC30US QOC40US QOC30US QOC30US 87.00 87.00 87.00 87.00 87.00 87.00 24 Main Wire Size AWG/kcmil Al or Cu 6–1 6–2/0 6–2/0 4–250 Equipment Ground Bar Kit (Order Separately) Box No. See Page 1-17 Cat. No. $ Price PK9GTA PK12GTA PK15GTA PK15GTA PK18GTA PK15GTA PK18GTA 13.40 15.80 17.10 17.10 18.80 17.10 18.80 5 6 6 7 8 7 8 PK18GTA PK15GTA PK18GTA PK18GTA PK23GTA PK15GTA PK23GTA and LK100ANg PK18GTA PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA 18.80 17.10 18.80 18.80 21.30 17.10 9 9 9 10 9 9 36 12 1287.00 QO12436M200TFTh 1200.00 QOC40UF QOC40US 87.00 10 4–250 QOC30UF QOC30US 87.00 18.80 9 30 30 0 879.00 QO130M200 792.00 30 40 10 957.00 QO13040M200 870.00 QOC30UF QOC30US 87.00 21.30 9 40 40 0 1121.00 QO140M200 1034.00 QOC40UF QOC40US 87.00 21.30 10 40 60 20 1431.00 QO14060M200 1344.00 QOC40UF QOC40US 87.00 21.30 10 42 42 0 1220.00 QO142M200 1109.00 QOC42UF QOC42US 111.00 21.30 11 New! 42 52 10 1382.00 QO14252M200 1271.00 QOC42UF QOC42US 111.00 21.30 11 4–300 40 40 0 1196.00 QO140M225 1085.00 QOC42UF QOC42US 111.00 21.30 11 225 A 42 42 0 1253.00 QO142M225 1142.00 QOC42UF QOC42US 111.00 21.30 11 Fixed Mains—Factory-installed LAL Main Circuit Breaker, 42 kA Short Circuit Current Ratingc QONQ42MS300 4243.00 (1) 4–500 (int)d 300 A 42 42 0 4909.00 NC62NQVF NC62NQVS 591.00 16 PK27GTAe 33.80 MH62 (box)f 75.00 or (2) 4–3/0 or QONQ42MS400 PK15GTA6 53.00 4243.00 (1) 4–500 (int)d NC62NQVF NC62NQVS 591.00 16 400 A 42 42 0 4909.00 MH62 (box)f 75.00 or (2) 4–250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. c UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H circuit breakers only. d Interior only, order box separately. e PK27GTA includes a 6–2/0 Al/Cu lug. f PE1A Discount Schedule. g Factory included. h Supplied with feed-thru lugs. 200 A Main Lug Kits Table 1.19: Field-Installed Main Lugs (Convertible Load Centers Only) Use on Lug Wire Sizej Convertible Load Center Cat. No. $ Price AWG/kcmil with Mains Rating Al or Cu 125 A 100–125 A QOL125k 44.10 6–2/0 225 A 150–225 A QOL225k 104.00 6–300 i Do not exceed the load center mains rating. j Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under main wire size. k If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13. Main Lug Ratingi QOL125 QOL225 QO130M150 1-6 DE3A PE1A Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® Load Centers Rainproof 1Ø, Main Lugs, Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1Ø3W—120/240 Vac—UL Listed Mains Rating Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 1-2 and 1-3.) Spaces Max. Single Pole Circuitsa Max. Tandem Circuit Breakers $ Price (Interior, Box and Cover) Main Wire Size AWG/kcmil Load Center Box and Interior Cat. No. $ Price Equipment Ground Bar Kit (Order Separately) Al Cu Cat. No. $ Price 102.00 14–4 14–4 Factory-installed 113.00 131.00 143.00 158.00 231.00 174.00 279.00 152.00 12–6 12–3 14–6 14–4 PK3GTA1 PK4GTA PK7GTA Factory-installed PK7GTA PK7GTA PK7GTA PK7GTA Factory-included Box No. See Page 1-17 Non-Metallic Enclosure Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating 60 A 2 4 2 102.00 QO24L60NRNM — 1NM R A I N P R O O F Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating 40 A 2 2 0 113.00 QO2L40RBb 70 A 2 4 2 131.00 QO24L70RBb 6 12 6 143.00 QO612L100RBc 100 A 6 12 6 158.00 QO612L100TRBc 8 16 8 231.00 QO816L100RBc 6 12 6 174.00 QO612L100RBCUcd 100 A 8 16 8 279.00 QO816L100RBCUcd 125 A 4 8 4 152.00 QO148L125GRBd Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus 12 12 0 285.00 QO112L125GRB 12 24 12 365.00 QO11224L125GRB 125 A 16 24 8 435.00 QO11624L125GRB 24 24 0 522.00 QO124L125GRB Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus 150 A 30 30 0 587.00 QO130L150GRB 12 12 0 480.00 QO112L200GRB 30 30 0 666.00 QO130L200GRB 30 40 10 714.00 QO13040L200GRB 200 A 40 40 0 971.00 QO140L200GRB 40 60 20 1262.00 QO14060L200GRB New! 42 52 10 1194.00 QO14252L200GRB 225 A 42 42 0 1310.00 QO142L225GRB 285.00 365.00 435.00 522.00 587.00 480.00 666.00 714.00 971.00 1262.00 1194.00 1310.00 8–1 8–1 12–2/0 14–2/0 6–2/0 4–250 4–250 4–300 11.40 10.80 11.70 — 11.70 11.70 11.70 1R 1R 2R 2R 2R 2R 2R 15R — — — — 3R 3R 4R 4R PK9GTA Factory-included PK15GTA Factory-included PK15GTA Factory-included PK15GTA Factory-included PK23GTA, LK100AN Factory-included PK9GTA Factory-included PK23GTA, LK100AN Factory-included PK23GTA, LK100AN Factory-included PK23GTA, LK100AN Factory-included (2) PK15GTA, (1) LK100AN Factory-included (2) PK15GTA, (1) LK100AN Factory-included PK23GTA, LK100AN Factory-included 1 Metallic Enclosure LOAD CENTERS Table 1.20: 6R 5R 6R 6R 7R 7R 8R 8R 1Ø3W—120/240 Vac—UL Listed Table 1.21: Mains Rating R A I N P R O O F Main Circuit Breaker Order QO, QOT, QO-GFI, QO-AFI, QO-EPD and QO-PL branch circuit breakers from pages 1-2 and 1-3. Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers $ Price (Interior, Box and Cover) Load Center Box and Interior Cat. No. $ Price Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating —Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg QOM1 Main Circuit Breaker Frame Size—Copper Bus 12 12 0 461.00 QO112M100RB 461.00 100 A 16 16 0 504.00 QO116M100RB 504.00 20 20 0 552.00 QO120M100RB 552.00 125 A 24 24 0 954.00 QO124M125RB 954.00 Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating —Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg QOM2 Main Circuit Breaker Frame Size—Copper Bus 20 30 10 953.00 QO12030M150RB 953.00 150 A 30 30 0 1122.00 QO130M150RB 1122.00 20 40 20 954.00 QO12040M200RB 954.00 30 30 0 1154.00 QO130M200RB 1154.00 30 40 10 1179.00 QO13040M200GRB 1179.00 200 A 40 40 0 1397.00 QO140M200RB 1397.00 40 60 20 1815.00 QO14060M200RB 1815.00 42 42 0 1469.00 QO142M200RB 1469.00 New! 42 52 10 1718.00 QO14252M200RB 1718.00 225 A 42 42 0 1631.00 QO142M225RB 1631.00 QOM1/QOM2 Feed-Thru Main Circuit Breaker With Feed-Thru Lugs—Copper Bus, 22 kA Short Circuit Current Rating h 125 A 6 12 6 620.00 QO1612M125FTRBi 620.00 150 A 8 16 8 863.00 QO1816M150FTRBi 863.00 200 A 8 16 8 863.00 QO1816M200FTRB i 863.00 Main Wire Size AWG/kcmil Al or Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price Box No. See Page 1-17 PK9GTA PK12GTA PK15GTA PK15GTA 13.40 15.80 17.10 17.10 3R 4R 4R 4R 4–300 PK18GTA PK18GTA PK23GTA PK18GTA PK23GTA PK23GTA PK15GTA PK23GTA PK15GTA PK23GTA 18.80 18.80 21.30 18.80 21.30 21.30 17.10 21.30 17.10 21.30 5R 6R 5R 6R 6R 7R 7R 8R 8R 8R 4–2/0 4–250 4–250 PK12GTA PK15GTA-L PK15GTA-L 15.80 35.00 35.00 3R 6R 6R 6–2/0 6–2/0 4–250 4–250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Use 10 AWG maximum size wire for AFI and GFI circuit breaker. c 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. d Copper bus. e UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. f UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. g Side hinge door device; allow 1-1/4 in. on left side for door to open. h 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22 kA available fault current. i QO1612M125FTRB provided with QOM1 frame main circuit breaker. QO1816M150FTRB and QO1816M200FTRB provided with QOM2 frame main circuit breaker. © 2009 Schneider Electric All Rights Reserved DE3A Discount Schedule 1-7 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® Load Centers 3Ø, Main Lugs, Main Circuit Breaker Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 Table 1.22: 3Ø4W 208Y/120 Vac, 3Ø4W 240/120 Vac Delta and 3Ø3W 240 Vac Delta, UL Listed. (Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 1-2 and 1-3.) Mains Rating LOAD CENTERS I N D O O R Max. Number of 1P QO circuit breakers $ Price (Interior, Box and Cover) Indoor Cover with Door (Order Separately) Load Center Box and Interior Cat. No. Flush Cat. No. $ Price Surface Cat. No. Main Wire Size AWG/kcmil $ Price Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating a 60 A 3 107.00 QO403L60NF/S 107.00 Cover Included With Load Center (No Door) 12 369.70 QO312L125Gh 332.00 QOC16UF QOC16US 37.70 i 125 A 20 508.70 QO320L125Gh 471.00 QOC24UF QOC24US 37.70 i 24 577.70 QO324L125Gh 540.00 QOC24UF QOC24US 37.70 i 18 530.00 QO318L200Gh 443.00 QOC30UF QOC30US 87.00 i 200 A 30 707.00 QO330L200Gh 620.00 QOC30UF QOC30US 87.00 i 225 A 42 953.00 QO342L225Gh 842.00 QOC42UF QOC42US 111.00 i Equipment Ground Bar Kit (Order Separately) Al Cu Cat. No. — 10–6 6–2/0 6–2/0 PK4GTA Factory-incl.g Factory-incl.g Factory-incl.g Factory-incl.f Factory-incl.f Factory-incl.f 7.20 — — — — — — 13 6 7 7 9 9 11 PK15GTA PK18GTA PK18GTA PK23GTA PK18GTA PK23GTA PK23GTA 17.10 18.80 18.80 21.30 18.80 21.30 21.30 9 12 12 12 12 12 12 6–250 6–250 6–300 Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating b 100 A 27 1058.00 QO327M100c 971.00 QOC30UF QOC30US 87.00 i 4–2/0 125 A 30 1931.00 QO330MQ125dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 30 1931.00 QO330MQ150dh 1839.00 QOC342MQF QOC342MQS 92.00 150 A 4–300 42 2119.00 QO342MQ150dh 2027.00 QOC342MQF QOC342MQS 92.00 30 1931.00 QO330MQ200dh 1839.00 QOC342MQF QOC342MQS 92.00 200 A 4–300 42 2119.00 QO342MQ200dh 2027.00 QOC342MQF QOC342MQS 92.00 225 A 42 2119.00 QO342MQ225dh 2027.00 QOC342MQF QOC342MQS 92.00 4–300 6–300 4–2/0 4–300 4–300 4–300 4–300 $ Pricej Box No. See Pages 1-17 Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratingae 60 A 3 177.00 QO403L60NRB 177.00 — 10–6 PK4GTA 10.80 10R 12 485.00 QO312L125GRB 485.00 Factory Incl.g — 3R 6–2/0 6–2/0 20 629.00 QO320L125GRB 629.00 Factory Incl.g — 4R R Cover Included 18 618.00 QO318L200GRB 618.00 Factory Incl.f — 6R A 200 A 6–250 6–250 I 30 839.00 QO330L200GRB 839.00 Factory Incl.f — 6R N 225 A 42 1494.00 QO342L225GRB 1494.00 6–300 6–300 Factory Incl.f — 8R P R Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingb e O 100 A 27 1185.00 QO327M100RBc 1185.00 4–2/0 4–2/0 PK15GTA 17.10 6R O 125 A 30 2147.00 QO330MQ125RBd 2147.00 4–300 4–300 PK18GTA 18.80 14R F 150 A 30 2147.00 QO330MQ150RBd 2147.00 4–300 4–300 PK18GTA 18.80 14R Cover Included 30 2147.00 QO330MQ200RBd 2147.00 PK18GTA 18.80 14R 200 A 4–300 4–300 42 2333.00 QO342MQ200RBd 2333.00 PK23GTA 21.30 14R 225 A 42 2333.00 QO342MQ225RBd 2333.00 4–300 4–300 PK23GTA 21.30 14R Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. b 25 kA short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k AIR branch circuit breakers. c Includes factory-installed back fed QO3100VH main circuit breaker. d 65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers. e Side hinge door device allow 1-1/4 in. on left side for door to open. f PK23GTA and LK100AN. g PK15GTA. h For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating when QODX...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used). i DE3A Discount Schedule j DE2 Discount Schedule 125 A Table 1.23: 3Ø Main Circuit Breakers Field-installed alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A. Do not exceed the load center main rating. k Amperage 25 k AIR 65 k AIR 100 k AIRk 70 A QDL32070 QGL32070 QJL32070 80 A QDL32080 QGL32080 QJL32080 90 A QDL32090 QGL32090 QJL32090 100 A QDL32100 QGL32100 QJL32100 110 A QDL32110 QGL32110 QJL32110 125 A QDL32125 QGL32125 QJL32125 150 A QDL32150 QGL32150 QJL32150 175 A QDL32175 QGL32175 QJL32175 200 A QDL32200 QGL32200 QJL32200 225 A QDL32225 QGL32225 QJL32225 $ Price (DE2) 1784.00 2442.00 2796.00 When these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating is 65 kA at 240 Vac and 100 kA at 208 Vac. Table 1.24: 3Ø Main Lug Kits Field-installed main lugs for convertible 3Ø main circuit breaker load centers. QO342MQ200 1-8 QO312L125G Main Lug Amperage Rating 125 A 225 A DE3 DE3A DE2 Cat. No. QOL3125 QOL3225 Discount Schedule $ Price 67.00 158.00 Lug Wire Size AWG/kcmil 6–2/0 Cu/Al 6–300 Cu/Al © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® and Homeline® Load Centers Backup Power Solutions Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us Order QO, QOT, QO-EPD, QO-GFI, and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3. Mains Max. Single Rating Spaces Pole (A) Circuits a R A I N P R O O F Load Center Box, Interior and Cover Cat. No. Main Wire Size AWG/kcmil $ Price Cat. No. $ Price Generator Panels for Sub-Feed Applications Type 1 (Indoor) 1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating 30 4 8 4 QO48M30DSGP 563.00 60 4 8 4 QO48M60DSGP Al Cu Box No. See Page 1-12 14–8 14–8 4 8–2 8–2 4 Equipment Grounding Bar Kit (Order Separately) 563.00 PK7GTA 11.70 Generator Panels with Power Inlet Plug for Sub-Feed Applications Type 3R (Outdoor) 1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating 4 8 4 QO1DM10020TRBR 848.00 4 8 4 QO1DM10030TRBR 848.00 100 — — Factory-Installed 4 8 4 QO1DM10050TRBR — — 8–2 1148.00 — — 1 I N D O O R Max. Tandem Circuit Breakers LOAD CENTERS Table 1.25: Generator Panel—Automatic Transfer Switch (Contact your local Square D Field Sales office for more information.) b 1-Phase 3-Wire 120/240 Vac Factory- or Field-Installed Main Circuit Breaker 22,000 RMS Sym. Ampere Short Circuit Current Rating 150 38 42 42 QO13842MX150 1349.00 PK23GTA 21.30 4–250 4–250 12 200 38 42 42 QO13842MX200 1499.00 PK23GTA 21.30 4–250 4–250 12 I N 38 42 42 QO13842MX225 1649.00 4–250 4–250 12 225 PK23GTA 21.30 D 38 42 42 QO13842UX225 c 1199.00 4–250 4–250 12 O QOC38MXUF (Cover) 149.00 — O R 150 14 28 28 QO11428MX150FTRBde 1349.00 PK23GTA 21.30 4–250 4–250 7R 14 28 28 QO11428MX200FTRBde 1499.00 PK23GTA 21.30 4–250 4–250 7R 200 14 28 28 QO11428UX200FTRBcde 1199.00 PK23GTA 21.30 4–250 4–250 7R QO Load Center Accessories Cat. No. $ Price Schedule For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that QO2DTI 24.90 DE2E only one circuit breaker can be “ON’’ at a time. QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual QO2DTIM 63.00 DE2E power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for backManual Transfer Equipment Kit up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LA 102.00 DE3A Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back- PK4DTIM4HA 102.00 DE3A up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up PK4DTIM4LAL 102.00 DE3A power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P QOCRBGK1 105.00 DE3A main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. Generator Circuit Breaker For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main QOCGK2 105.00 DE3A circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. Interlock Kit For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) QORBGK2 105.00 DE3A with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b One main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max.) ordered separately. Automatic Transfer Switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor. c Universal mains – No factory-installed main circuit breaker or main lugs. QOM2 frame size, field-install 22 k AIR. Main circuit breaker or main lugs (see pages 1-5 or 1-6). d Supplied with feed-thru lugs. e Device is rated NEMA 3R and can be used for indoor or outdoor applications. QO2DTI Installed QO2DTI ON OFF ON OFF 1 3 ON OFF 5 ON OFF PK4DTIM4HA QOCGK2 Installed © 2009 Schneider Electric All Rights Reserved DE3A Discount Schedule 1-9 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® Load Centers Special Applications Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 Table 1.26: Mains Rating QO Special Application (Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.) Short Circuit Current Rating Max. 1P Circuits a Spaces Load Center b Box, Interior, and Cover Max. Tandem Circuit Breakers Cat. No. 0 2 QO2L30TTSd QO24L50TTSe LOAD CENTERS Manufactured Housing: 1Ø2W 120 Vac—Main Lugs Only—CSA Certified 30 Ac 10 kA 2 2 4 50 A 10 kA 2 Equipment Ground Bar Kit (Order Separately) $ Price Cat. No. 51.00 78.00 Main Wire Size AWG/kcmil Al Cu Box No. See Page 1-17 12–10 — 14–10 14–6 1 2 $ Price Factory-installed 1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified 30 A 10 kA 3 5 2 QO35FM30TTF/S 83.00 Factory-installed 1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified 70 A 10 kA 2 4 2 QO24L70TSe 78.00 10 kA 6 12 6 QO612L100TF/Sg 86.00 Factory 10 kA 6 12 6 QO612L100DTF/Sg 101.00 Installed 100 A 10 kA 8 16 8 QO816L100TF/Sg 137.00 10 kA 8 16 8 QO816L100DTF/Sg 159.00 Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package I N D O O R f 3 12–3 14–4 2 4 4 4 4 4–1 Convertible Mains—Factory-Installed Main Lugs i—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus 65 kA 12 0 QO112L125GC 188.00 PK12GTA Incl. 12 125 A 65 kA 12 24 12 QO11224L125GC 249.00 PK15GTA Incl. 20 65 kA 20 0 QO120L125GC 284.00 PK15GTA Incl. Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus 150 A 65 kA 30 30 0 QO130L150TC 452.00 PK23GTA, LK100AN Installed 200 A 65 kA 30 40 10 QO13040L200GC 575.00 PK23GTA, LK100AN Incl. 6–2/0 6–2/0 6–2/0 6 6 7 6–250 6–250 9 9 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j 22 kA 12 12 0 QO112M100C 351.00 PK9GTA 13.40 4–1/0 5 22 kA 12 20 8 QO11220M100C 413.00 PK15GTA 17.10 4–1/0 5 100 A 22 kA 16 16 0 QO116M100C 395.00 PK12GTA 15.80 4–1/0 6 22 kA 20 20 0 QO120M100C 446.00 PK15GTA 17.10 4–1/0 6 125 A 22 kA 32 32 0 QO132M125C 1041.00 PK18GTA 18.80 6–2/0 8 Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j 22 kA 20 30 10 QO12030M150C 843.00 PK18GTA 18.80 4–250 9 150 A 22 kA 30 30 0 QO130M150C 870.00 PK18GTA 18.80 4–250 9 22 kA 20 40 20 QO12040M200C 843.00 PK23GTA 21.30 4–250 9 22 kA 30 30 0 QO130M200C 896.00 PK18GTA 18.80 4–250 9 200 A 22 kA 30 40 10 QO13040M200C 974.00 PK23GTA 21.30 4–250 9 22 kA 40 40 0 QO140M200C 1137.00 PK23GTA 21.30 4–250 10 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. b Order F for flush device or S for surface device. c Mains rating 25 A when Al wire is used. d Will not accept Qwik-Gard® QO-GFI or QO-AFI circuit breaker. e Use 10 AWG maximum size wire for GFI and AFI circuit breakers. f Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2. g 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. h UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. i UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. j 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current. Table 1.27: Auxiliary Gutter UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsk. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501 k l Cat. No. $ Price SDAG26 338.00 One tap kit required for each riser wire. When used with B300 bolt-on hubs. Table 1.28: Cover Flush Width 13.50 Height 26.12 Depth 3.75 Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26 Cat. N0. $ Price Use with Auxiliary Gutter Cat. No. SDGT30020 SDGT300300 81.00 120.00 SDAG26 SDAG26 SDGT300C10C 49.70 SDAG26 SDGT300C300C 70.00 SDAG26 QOGL20 Grounding Terminals 40.70 SDAG26 1-10 Conduit Riser Size 1-3/4, 2, 2-1/2 or l3 Riser Wire Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL030516H1 (Not included) Anderson VCEL030516H1 (Not included) Mechanical (Included) DE3A Discount Schedule Tap Off Wire Al/Cu Wire Size (2) 6 AWG–300 kcmil (2) 6 AWG–300 kcmil (2) 4 AWG–300 kcmil (2) 4 AWG–300 kcmil (2) 6–2/0 AWG Lug Type Mechanical (Included) Mechanical (Included) Anderson VCEL02114S1 (Not Included) Anderson VCEL030516H1 (Not included) — Al/Cu Wire Size (1) 6–2/0 AWG (1) 6 AWG–300 kcmil (1) 8–1/0 AWG (1) 4 AWG–300 kcmil — © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® and Homeline® Load Centers Load Center Value Pack Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us Load Center Value Pack I N D O O R R A I N P R O O F Max. Tandem Circuit Breakers Equipment Ground Bar Kit (Order Separately) Load Center Box, Interior, Cover and Branch Circuit Breakers Cat. No. Included Load Center/Circuit Breakers $ Price QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 1-2 and 1-3. Main Circuit Breaker 100 A 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 200 A 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 200 A 30 40 10 QOVP10 (1) QO13040M200C, (10) QO120 Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14. Main Lugs 125 A 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 200 A 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 Main Circuit Breaker 100 A 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 100 A 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 150 A 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 200 A 20 40 20 HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230 200 A 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 200 A 30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 200 A 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 200 A 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 200 A 40 40 0 HOMVP15 (1) HOM40M200C, (10) HOM120 Cat. No. 839.00 1103.00 1328.00 PK18GTA PK23GTA PK23GTA 353.00 962.00 Included Included 528.00 528.00 983.00 965.00 1083.00 1083.00 1328.00 1328.00 1346.00 PK15GTA PK15GTA PK23GTA Included Included Included Included Included PK23GTA 1253.00 PK23GTA Main Wire Size AWG/kcmil Al/Cu $ Price 18.80 21.30 21.30 Box No. See Pages 1-17 4–2/0 4–250 4–250 8 9 9 6–2/0 4–250 6 10 17.10 17.10 21.30 — — — — — 21.30 4–2/0 4–2/0 4–250 4–250 4–250 4–250 4–250 4–250 4–250 7 7 10 9 10 10 10 10 12 21.30 4–250 6R — — LOAD CENTERS Max. 1P Circuitsa 1 Mains Rating 1Ø3W—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers Spaces Table 1.29: Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14. Main Circuit Breaker 200 A 20 40 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. Riser Panels Table 1.30: Mains Rating 1Ø3W 120/240 Vac—Offset Interior Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interior bc Spaces Max. Single Pole Circuitsd Max. Tandem Circuit Breakers Load Center Box and Interior Cat. No. $ Price Load Center Cover Cat. No. $ Price Equipment Ground Bar Kit (Order Separately) Cat. No. Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus 125 A 12 24 12 QO11224L125WG 338.00 QOC20UFWG 53.00 PK15GTA I 125 A 20 30 10 QO12030L125WG 465.00 QOC20UFWG 53.00 PK15GTA N D Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating O QOM2 Main Frame Size–Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below–Copper Bus O 200 A 30 40 10 QO13040L200WG 701.00 QOC30UFWG 102.00 PK23GTA R Convertible Mains—Factory-installed Main Circuit Breaker—22 kA Short Circuit Current Rating QOM2 Main Frame Size–Convertible to Main Lugs (See page 1-6)—Copper Bus 200 A 24 24 0 QO124M200WG125e 683.00 QOC30UFWG 102.00 PK23GTA Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. d Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. e Comes with 125 A main circuit breaker factory installed. Main Wire Size AWG/kcmil $ Price Al Cu Box No. See Page 1-17 17.10 17.10 6–2/0 6–2/0 14 14 21.30 4–250 23 21.30 4–250 23 Panelboard-style Covers for Riser Panels Mono-Flat® Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used when panel has been converted to a main circuit breaker panel. f f Mains Rating of Load Center Cat. No. 125 A NQC20FWG 200 A NQC30FWG Order catalog number PK4FL for field-installed lock kit. © 2009 Schneider Electric All Rights Reserved $ Price 117.00 180.00 DE3A Discount Schedule 1-11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Load Center Accessories QO Load Center Accessories Class 1130 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 Table 1.31: Retaining Kit LOAD CENTERS Miscellaneous QO Load Center Accessories Description Cat. No. Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB, PK2MB QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3Ø load centers PK3MB Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers. PK5RK Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2LA For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2HA For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers QO1SE For use on 1Ø3W, 150 Vac maximum SDSA1175 For use on 3Ø4W, 650 Vac maximum SDSA3650 Surge Arresters: QO Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. QO2175SB HOM2175SB Homeline Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. Surge Arrester UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker QOSAMK Mounting Kit: load centers Replacement Cover 1 through 42 numbered universal replacement directory label for load center covers LSDL Directory Label: Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS Stickers: $ Price Schedule 7.20 DE3A 14.70 14.70 DE3A DE3A 14.70 DE3A 14.70 DE3A 3.60 92.00 248.00 159.00 159.00 DE3A DE1B DE1B DE1B DE1B 11.40 DE3A 0.54 DE5 0.75 DE5 PK2MB QOSAMK PK3MB 1-12 DE1B DE2E DE3A DE5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® and Homeline® Accessories and Voltage testers Load Center Accessories Class 1130, 6610 / Refer to Catalog 1100CT0501 www.schneider-electric.us Description Fills opening in covers if twistout is removed in error Fills main circuit breaker opening in convertible load center covers100–125 A Filler Plates Fills main circuit breaker opening in convertible load center covers150–225 A Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU, QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP. Lock Kits Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers Use with 300 and 400 ampere indoor load centers. Field-installed for 12– 2 Al or 14–4 Cu AWG wire Field-installed for 6–2/0 Al/Cu AWG wire Neutral / Ground Lugs Field-installed for 14–2/0 Al/Cu AWG wire Field-installed for 2–3/0 Al/Cu AWG wire Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center Standard PK15GTA with a 1–4/0 Al/Cu Lug Standard PK18GTA with a 1–4/0 Al/Cu Lug Ground Bar Kits Standard PK23GTA with a 1–4/0 Al/Cu Lug Insulator Kit for PK7GTA through PK27GTA For padlocking main circuit breakers in convertible load centers OFF..........50–125 A, QOM1 Frame Size Handle Padlock Attachment: For padlocking main circuit breakers in convertible load centers OFF..........100–225 A, QOM2 Frame Size a QO403L60NF/S does not have provisions for a field-installed lock. Cat. No. QOFP QOM1FP QOM2FP KFP Q2FP $ Price Schedule 3.60 DE3A 20.30 DE3A 20.30 DE3A 20.30 DE3A 20.30 DE3A PK8FLa 98.00 DE3A PK6FL PK4FL LK70AN LK100AN LK125AN LK150AN LK225AN PK15GTAL PK18GTAL PK23GTAL PKGTAB QOM1PA QOM2PA 93.00 90.00 10.10 10.80 22.10 32.40 33.20 35.00 37.80 40.70 43.80 11.00 11.00 DE3A PE1A DE3A DE3A DE3A DE3A DE3A DE3A DE3A DE3A DE3A DE2E DE2E LOAD CENTERS QO Load Center Accessories 1 Table 1.32: QOFP PKGTAB PK4FL PK6FL and PK8FL Table 1.33: Homeline Load Center Accessories Description Handle Padlock Attachment: 50–125 A 100–225 A For padlocking main circuit breakers in convertible load center, “OFF” Fills opening in covers if twistout is removed in error Filler Plates Neutral Lugs Retaining Kit Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire Field-installed for 6–2/0 AWG Al/Cu wire Field-installed for 14–2/0 AWG Al/Cu wire Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100–125 A convertible main load centers, Series S01 and S02 Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150–225 A convertible main load centers, Series S01 and S02 Secures circuit breaker to interior when used as a back-fed main. For 2P 150–200 A circuit breakers $ Price Schedule 11.00 DE2E 11.00 DE2E 3.20 DE3C 20.30 DE3A 20.30 DE3A 10.10 DE3B 10.80 DE3B 22.10 DE3B 33.20 DE3A HOM1RK 6.50 DE3C HOM4RK2LA 14.70 DE3C HOM4RK2HA 14.70 DE3C HOM5RK 14.70 DE3C Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 93.00 DE3A Replacement Cover Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5 PSDS 0.75 DE5 Miscellaneous Generator Circuit Breaker Interlock Kit 100–125 A 150–225 A Fills main circuit breaker opening in convertible load centers Cat. No. QOM1PA QOM2PA HOMFP QOM1FP QOM2FP LK70AN LK100AN LK125AN LK225AN Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits Stickers: For use on “S” Series NEMA 1 and “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker. For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. © 2009 Schneider Electric All Rights Reserved DE2E DE3A DE3B DE3C DE3D DE3E DE5 PE1A Discount Schedule HOMCRBGK1 105.00 DE3D HOMCGK2 105.00 DE3D HOMRBGK2 105.00 DE3D 1-13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Homeline® Load Centers Indoor, 1Ø, Main Lug, Main Circuit Breaker Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us Mains Rating 1Ø3W—120/240 Vac—UL Listed—10 kA Short Circuit Current Rating Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers Load Center Box, Interior and Cover b Main Wire Size AWG/kcmil $ Price (DE3C) Cat. No. Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. $ Price (DE3A) Box No. See Page 1-17 LOAD CENTERS Table 1.43: Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 1-14 I N D O O R 59.00 78.00 86.00 12–3 14–4 8–1 12–2/0 132.00 150.00 174.00 204.00 260.00 237.00 288.00 344.00 375.00 396.00 357.00 575.00 417.00 420.00 464.00 479.00 618.00 671.00 839.00 804.00 732.00 14–2/0 6–2/0 PK3GTA1 11.40 PK7GTA 11.70 PK7GTA Factory-included PK15GTA Factory-installed PK15GTA Factory-installed PK15GTA PK15GTA Factory-installed Factory-installed 17.10 — 17.10 — 17.10 17.10 — — 4–250 4–250 PK23GTA Factory-installed — 4–250 Factory-installed — 4–250 6–250 PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed Factory-installed Factory-installed PK23GTA 21.30 21.30 — — 21.30 — — — 21.30 2 4 21 6 6 6 6 8 8 8 8 1 Factory-installed Fixed Main Lugs 70 A 2 4 2 HOM24L70F/Sdc 100 A 6 12 6 HOM612L100F/Sce 125 A 4 8 4 HOM48L125GC Convertible Mains—Factory-installed Main Lugs QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16) 8 16 8 HOM816L125C 8 16 8 HOM816L125TC 12 12 0 HOM12L125C 12 24 12 HOM1224L125TC 125 A 16 24 8 HOM1624L125C 20 20 0 HOM20L125C 20 24 4 HOM2024L125TC 24 24 0 HOM24L125TC Convertible Mains—Factory-installed Main Lugs QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16) 30 30 0 HOM30L150C 150 A 30 30 0 HOM30L150TC 16 32 16 HOM1632L200TC 200 A 16 32 16 HOM1632L200TCFTf 20 40 20 HOM2040L200TC 30 30 0 HOM30L200C 30 30 0 HOM30L200TC 30 40 10 HOM3040L200TC 200 A 40 40 0 HOM40L200C 40 40 0 HOM40L200TC 40 60 20 HOM4060L200TC New! 42 52 10 HOM4252L200TC 225 A 42 42 0 HOM42L225C 10 10 9 10 9 10 10 10 12 12 12 12 12 Main Circuit Breaker—22 kA Short Circuit Current Rating Convertible Mains—Factory-installed Main Circuit Breaker QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16) 8 16 8 HOM816M100C 315.00 8 16 8 HOM816M100TC 333.00 12 12 0 HOM12M100C 294.00 100 A 12 24 12 HOM1224M100TC 384.00 20 20 0 HOM20M100C 396.00 24 24 0 HOM24M100C 513.00 30 30 0 HOM30M100C 672.00 12 24 12 HOM1224M125C 606.00 12 24 12 HOM1224M125TC 620.00 125 A 24 24 0 HOM24M125C 710.00 30 30 0 HOM30M125C 812.00 Convertible Mains—Factory-installed Main Circuit Breaker QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16) 16 32 16 HOM1632M150TC 636.00 150 A 20 30 10 HOM2030M150TC 750.00 30 30 0 HOM30M150C 776.00 12 24 12 HOM1224M200TC 572.00 16 32 16 HOM1632M200TC 675.00 20 40 20 HOM2040M200C 711.00 20 40 20 HOM2040M200TC 764.00 30 30 0 HOM30M200C 798.00 200 A 30 40 10 HOM3040M200TC 891.00 40 40 0 HOM40M200C 1019.00 40 60 20 HOM4060M200C 1367.00 42 42 0 HOM42M200C 1094.00 New! 42 52 10 HOM4252M200C 1313.00 225 A 42 42 0 HOM42M225C 1116.00 6–1 6–1 6–2/0 6–2/0 6–1 6–2/0 6–2/0 6–2/0 4–250 4–250 4–250 PK15GTA Factory-installed PK15GTA Factory-installed PK15GTA PK15GTA PK23GTA PK15GTA Factory-installed PK15GTA PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed Factory-installed PK23GTA Factory-installed PK23GTA Factory-installed PK23GTA PK23GTA PK23GTA PK23GTA PK23GTA 17.10 — 17.10 — 17.10 17.10 21.30 17.10 — 17.10 21.30 — — 21.30 — — 21.30 — 21.30 — 21.30 21.30 21.30 21.30 21.30 5 5 6 6 7 8 10 6 6 8 10 9 9 10 9 9 9 9 10 10 12 12 12 12 12 Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See page 1-16) 16 32 16 HOM1632U200TC 293.00 200 A 20 40 20 HOM2040U200TC 357.00 4–250 30 40 10 HOM3040U200TC 530.00 Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b C at end of catalog number indicates combination flush/surface cover included with device. c F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door. d HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. e 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. f Supplied with feed-thru lugs. © 2009 Schneider Electric All Rights Reserved DE3A DE3C Discount Schedule Factory-installed Factory-installed Factory-installed — — — 9 9 10 1-15 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Homeline® Load Centers Rainproof, 1Ø, Main Lug, Main Circuit Breakers Class 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 1 Table 1.44: 1Ø3W 120/240 Vac UL Listed Load Centers Mains Rating Spaces Max. Single Pole Circuits a Max. Tandem Circuit Breakers Load Center Box, Interior and Cover Cat. No. (DE3C) Main Wire Size AWG/kcmil $ Price Al Cu Equipment Ground Bar Kit (Order Separately) Cat. No. (DE3A) $ Price Box No. See Page 1-17 Main Lugs (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 10 kA Short Circuit Current Rating LOAD CENTERS R A I N P R O O F Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating 70 A 2 4 2 HOM24L70RBb 111.00 12–3 14–4 PK4GTA 10.80 100 A 6 12 6 HOM612L100RBf 129.00 8–1 PK7GTA 11.70 125 A 4 8 4 HOM48L125GRB 137.00 12–2/0 14–2/0 PK7GTA Factory-included Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below) 8 16 8 HOM816L125RB 248.00 PK15GTA 17.10 12 12 0 HOM12L125RB 234.00 PK15GTA 17.10 125 A 6–2/0 12 24 12 HOM1224L125RB 278.00 PK15GTA 17.10 20 20 0 HOM20L125RB 383.00 PK15GTA 17.10 Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below) 12 12 0 HOM12L200RB 423.00 PK23GTA 21.30 20 40 20 HOM2040L200RB 560.00 PK23GTA 21.30 30 30 0 HOM30L200RB 587.00 PK23GTA 21.30 200 A 30 40 10 HOM3040L200RB 759.00 — — 4–250 40 40 0 HOM40L200RB 911.00 PK23GTA 21.30 New! 1R 2R 15R 3R 3R 3R 4R 5R 6R 7R — 14R 40 60 20 HOM4060L200RB 1139.00 PK23GTA 21.30 14R 42 52 10 HOM4252L200RB 1092.00 PK23GTA 21.30 14R Main Circuit Breaker (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 22 kA Short Circuit Current Rating Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d 8 16 8 HOM816M100RB 429.00 6–1 PK15GTA 17.10 3R 12 12 0 HOM12M100RB 416.00 PK15GTA 17.10 3R 100 A 20 20 0 HOM20M100RB 531.00 6–2/0 PK15GTA 17.10 4R 24 24 0 HOM24M100RB 606.00 PK15GTA 17.10 6R 8 16 8 HOM816M125RB 716.00 PK15GTA 17.10 3R 125 A 6–2/0 24 24 0 HOM24M125RB 858.00 PK15GTA 17.10 6R Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) 150 A 30 30 0 HOM30M150RB 978.00 4–250 PK23GTA 21.30 7R R 20 40 20 HOM2040M200RB 872.00 PK23GTA 21.30 6R A 30 30 0 HOM30M200RB 1004.00 PK23GTA 21.30 7R I N 30 40 10 HOM3040M200RB 1152.00 PK23GTA 21.30 7R 200 A 4–250 P 40 40 0 HOM40M200RB 1277.00 PK23GTA 21.30 14R R 40 60 20 HOM4060M200RB 1596.00 PK23GTA 14.20 14R O New! O 42 52 10 HOM4252M200RB 1532.00 PK23GTA 14.20 14R F 16 24 8 HOM1624M225RB 1182.00 PK15GTA 17.10 7R 225 A 4–250 42 42 0 HOM42M225RB 1323.00 PK23GTA 21.30 14R Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs c 150 A 8 16 8 HOM816M150FTRB 785.00 4–250 PK15GTAL 35.00 6R 200 A e 8 16 8 HOM816M200FTRB 785.00 4–250 PK15GTAL 35.00 6R Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker or Main Lugs c QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See Kits Below) 200 A 8 16 8 HOM816U200FTRB 446.00 4–250 PK15GTAL 35.00 6R Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire. c Side hinge door device allow 1-1/4 in. on left side for door to open. d 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. e Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire. f 70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker. Field-Installed Kits Table 1.45: Main Lug Kit QOL125 QOL225 1-16 Field-Installed Mains, Convertible Load Centers Only Main g Use on Convertible Load $ Price Lug Wire Size j Cat. No. Ampere Rating Center with Mains Rating (DE3A) AWG/kcmil 125 A 100–125 A QOL125 44.10 6–2/0 Al or Cu Main Lug h — 225 A 150–225 A QOL225 104.00 6–300 Al or Cu 50 A 100–125 A QOM50VH 140.00 60 A 100–125 A QOM60VH 140.00 70 A 100–125 A QOM70VH 140.00 80 A 100–125 A QOM80VH 201.00 QOM1 12–2/0 Al or Cu 90 A 100–125 A QOM90VH 201.00 100 A 100–125 A QOM100VH 201.00 110 A 125 A QOM110VH 468.00 Main Circuit Breaker i 125 A 125 A QOM125VH 468.00 100 A 150–225 A QOM2100VH 468.00 125 A 150–225 A QOM2125VH 468.00 150 A 150–225 A QOM2150VH 468.00 QOM2k 4–300 Al or Cu 175 A 200–225 A QOM2175VH 468.00 200 A 200–225 A QOM2200VH 468.00 225 A 225 A QOM2225VH 468.00 g Do not exceed the load center mains rating. h If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13. i 22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. j Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see pages 1-5 through 1-11 under Main Wire Size. k Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00. Field-Installed Main Type Frame Size DE3A DE3C Discount Schedule © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® and Homeline® Load Centers Indoor Load Centers–Dimensions, Knockouts Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us A Indoor Knockout Information and Enclosure Dimensions A,B,C,D A,B,C A,B,C A A,B,C A Table 1.46: Enclosure Dimensions A,B,C A,B A B,C,D,E B,C,D,E C,D,E,F,G A A,B B,C,D,E C,D,E,F B,C,D,E A,B A A B,C,D,E B,C,D,E A,B,C,D B,C,D,E Box 4 in. 3.81 4.81 4.81 8.88 14.25 14.25 14.25 14.25 14.25 14.25 14.25 14.25 1 2 3 4 5 6 7 8 9 10 11 12 Box 3 Box 2 Box 1 B,C,D,E A A,B Table 1.47: C,D,E,F,G C,D,E,F,G mm 171 236 236 319 379 455 531 661 758 858 965 1000 in. 3.00 3.19 3.19 3.80 3.75 3.75 3.75 3.75 3.75 3.75 3.75 3.75 W Box No. mm 76 81 81 97 95 95 95 95 95 95 95 95 in. 5.88 14.25 20.00 20.00 20.00 5.88 7.56 9.62 8.88 8.55 14.25 13 14 15 16 17 18 19 20 21 22 23 H mm 149 362 508 508 508 149 192 244 226 217 362 in. 13.12 20.92 50.00 62.00 53.00 16.12 23.12 26.12 14.80 23.92 29.86 D mm 333 531 1270 1727 1346 409 587 663 376 608 758 in. 3.38 3.75 5.75 5.75 5.75 3.38 4.25 4.75 3.80 3.95 3.75 mm 86 95 146 146 146 86 108 121 97 100 95 Knockout Information Knockouts A A,B A B C Conduit Size 1/2 3/4 1 C,D,E,F,G D E 1-1/4 1-1/2 F G H I 2 2-1/2 3 3-1/2 C,D,E,F,G B,C,D,E C,D,E,F A A,B D,E,F,G C,D,E,F B,C,D,E C,D,E,F A A,B D in. 6.72 9.30 9.30 12.57 14.92 17.92 20.92 26.04 29.86 33.78 37.98 39.37 Symbol B,C,D,E B,C,D,E mm 97 122 122 226 362 362 362 362 362 362 362 362 Box 5 B,C,D,E Dimensions H 1 A W Box No. LOAD CENTERS Dimensions A B,C,D,E C,D,E,F A A,B B,C,D,E D,E,F,G B,C C,D,E,F,G D,E,F,G A A,B B,C,D,E D,E,F,G B,C A,B B,C,D,E C,D,E,F A,B A,B A A,B A A A A,B,C,D A,B,C,D Box 6 B,C,D,E C,D,E,F C,D,E,F,G D,E,F,G B,C,D,E Box 7 C,D,E,F,G D,E,F,G Box 10 A A,B C,D,E,F D,E,F,G A,B B,C B,C A,B,C,D C,D,E,F D,E,F,G Box 9 Box 8 B,C,D,E B,C,D,E A A,B B,C,D,E D,E,F,G A,B,C,D C,D,E,F D,E,F,G A,B,C,D D,E,F,G,H D,E,F,G,H,I C,D,E,F A,B,C A A,B D,E,F,G A,B B,C,D,E A,B C,D,E,F C,D,E,F A,B,C,D A A,B A A A,B,C,D C,D,E,F D,E,F,G A,B,C,D B,C,D,E A,B,C,D B,C,D,E C,D,E,F Box 14 Box 13 Box 12 Box 11 Box 15, 16, 17 A,B,C A C,D,E,F D,E,F,G B,C C,D,E,F E,F,G,H C,D,E,F A,B,C,D D,E,F,G A,B D,E,F,G D,E,F,G A,B B,C,D,E D,E,F,G A B,C,D,E A,B B,C,D,E B,C,D,E A A A,B B,C,D,E B,C,D,E C,D,E,F Box 18 © 2009 Schneider Electric All Rights Reserved Box 19 Box 20 Box 21 A,B,C,D C,D,E,F D,E,F,G B,C,D,E Box 22 Box 23 1-17 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com QO® and Homeline® Load Centers Rainproof—Dimensions, Knockouts, Bolt-on Hubs Class 1130, 1170 / Refer to Catalog 1100CT0501 www.schneider-electric.us 2 1 2" Hub Maximum 1 2 1 2" Hub Maximum Table 1.48: Enclosure Dimensions Dimensions W H in. mm in. 1NM 6.52 166 8.79 1Ra 4.88 124 9.38 2R 8.88 226 12.65 3R 14.75 375 18.92 4R 14.75 375 22.06 5R 14.75 375 26.04 6R 14.75 375 29.86 7R 14.75 375 33.78 8R 14.75 375 37.98 9R 4.56 116 6.50 10R 6.92 176 13.18 11R 7.56 192 23.24 12R 9.62 244 26.24 13R 6.92 176 16.18 14R 14.75 375 39.37 15R 8.88 226 14.80 16R 8.55 217 24.75 17R 8.88 226 12.65 HOME250SPA and QO260NATR top endwall has no hub opening. Box No. B,C B,C A,B A,B LOAD CENTERS Box Box 1NM 1NM A A,B A,B,C,D B,C,D,E A B,C,D,E Box 1R A,B B,C,D,E Box 2R 2 1 2" Hub Maximum 2 1 2" Hub Maximum C,D,E,F,G C,D,E,F,G C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F C,D,E,F Box 3R, 4R A,B,C A A,B C,D,E,F,G 2 1 2" Hub Maximum C,D,E,F Box 5R a Table 1.49: D mm 223 238 321 481 560 661 758 858 965 165 335 590 666 411 1000 376 629 321 in. 3.90 4.00 4.27 4.52 4.52 4.52 4.52 4.52 4.52 3.88 4.12 4.75 5.50 4.12 4.52 4.27 4.16 4.27 mm 99 102 108 115 115 115 115 115 115 99 105 121 140 105 115 108 106 108 Knockout Information Knockouts C,D,E,F,G A,B,C Symbol A B C D E F G H Conduit Size 1/2 in. 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. Box 9R C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F 2 1 2" Hub Maximum 2 1 2" Hub Maximum 2 1 2" Hub Maximum Box 6R, 7R, 8R 2 1 2" Hub Maximum 2 1 2" Hub Maximum B,C,D,E B,C,D,E A D,E,F,G Box 11R C,D,E,F Box 15R B,C,D,E C,D,E,F,G 2 2" Hub Maximum 1 A,B,C,D A,B B,C,D,E 2 2" Hub Maximum 1 B,C,D,E B, C, D, E B, C, D, E A Power lnlet B, C, D, E Box 10R, 13R 17R A,B C,D,E,F D,E,F,G E,F E,F,G,H A,B,C A A,B C,D,E,F,G C,D,E,F C,D,E,F Box 14R Box 16R Box 12R Bolt-On Hubs Square D equipment with “R’’ or “RB’’ suffix, designated NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. “RB’’ devices will accept 3/4 in. through 2-1/2 in. bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix “R’’ devices require 3 in. through 4 in. field cut opening. Hubs are suitable for use with conduit having ANSI standard taper pipe thread. Table 1.50: Bolt-On Hubs UL Listed for “RB” Devicesb Conduit Size 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. Hub Cat. No. B075 B100 B125 B150 B200 B250 $ Price b 33.30 33.30 61.35 102.00 Bolt-On Hubs UL Listed for Mounting in Field-Cut Opening Conduit Size 3 in. 3-1/2 in. 4 in. Hub Cat. No. B300 B350 B400 $ Price 1-18 33.30 Closing cap (Cat. No. BCAP) is provided factory-installed on each device having “RB’’ suffix. Price if ordered separately; $2.50 Table 1.51: “RB’’ Hub 33.30 DE1A 186.00 Discount Schedule 300.00 Designed for mounting in field cut opening. Includes gasket and four mounting bolts and nuts. 368.00 © 2009 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
advertisement