QO® Load Centers
Indoor-1Ø, Main Lug
Class 736, 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1Ø3W Load Centers, 120/240 Vac, UL Listed
Main Lugs (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI, and QO-PL branch circuit breakers from pages 1-2 and 1-3)
I
N
D
O
O
R
Max.
Tandem
Circuit
Breakers
Load Center
Box and Interior
$ Price
(Interior,
Box and
Cover)
Cat. No.
Indoor Cover with Door
(Order Separately)
$ Price
Flush
Cat. No.
Main Wire Size Equipment Ground Bar
AWG/kcmil
Kit (Order Separately) Box No.
See Page
1-17
$ Price
Al
Cu
Cat. No.
$ Price
Surface
Cat. No.
Fixed Mains—Factory-Installed Main Lugs—10 kA Short Circuit Current Ratingb
30 A
2
2
0
41.70
QO2L30Scd
41.70
12–10 14–10 PK3GTA1
11.40
70 A
2
4
2
69.00
QO24L70F/Sef
69.00
Cover Included—Without Door
12–3 14–4
PK4GTA
10.80
87.00
QO612L100F/Seg
87.00
8–1
PK7GTA
11.70
6
12
6
90.00
QO612L100DF/Seg
90.00
Cover Included—With Door
8–1
PK7GTA
11.70
100 A
131.00
QO816L100F/Seg
131.00
Cover Included—Without Door
8
16
8
8–1
PK7GTA
11.70
143.00
QO816L100DF/Seg
143.00
Cover Included—With Door
6
12
6
111.00 QO612L100DFCU/SCUegh
111.00
Cover Included—With Door
8–1
PK7GTA
11.70
100 A
8
16
8
174.00 QO816L100DFCU/SCUegh
174.00
Cover Included—With Door
8–1
PK7GTA
11.70
125 A
4
8
4
93.00
QO148L125GF/Sei
93.00
Cover Included—Without Door
12–2/0 14–2/0
PK7GTAl
Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Cu Busbj
12
12
0
196.70
QO112L125G
159.00 QOC16UF
QOC16US
37.70
PK9GTAl
12
24
12
235.70
QO11224L125G
198.00 QOC16UF
QOC16US
37.70
PK15GTAl
16
16
0
255.70
QO116L125G
218.00 QOC24UF
QOC24US
37.70
PK12GTAl
16
24
8
300.70
QO11624L125G
263.00 QOC24UF
QOC24US
37.70
PK15GTAl
125 A
6–2/0
20
20
0
271.70
QO120L125G
234.00 QOC24UF
QOC24US
37.70
PK15GTAl
20
24
4
370.70
QO12024L125G
333.00 QOC24UF
QOC24US
37.70
PK15GTAl
24
24
0
381.70
QO124L125G
344.00 QOC24UF
QOC24US
37.70
PK15GTAl
32
32
0
434.60
QO132L125G
395.00 QOC32UF Use Flush
39.60
PK23GTA, LK100ANl
Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating , QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Cu Busbj
20
30
10
419.00
QO12030L150G
332.00 QOC30UF
QOC30US
87.00
PK23GTA, LK100ANl
24
24
0
431.00
QO124L150G
344.00 QOC30UF
QOC30US
87.00
6–250
PK15GTAl
150 A
30
30
0
437.00
QO130L150G
350.00 QOC30UF
QOC30US
87.00
PK23GTA, LK100ANl
12
12
0
353.00
QO112L200G
266.00 QOC30UF
QOC30US
87.00
PK15GTAl
24
36
12
819.00
QO12436L200TFTk
732.00 QOC40UF
QOC40US
87.00
PK23GTA, LK100ANl
30
30
0
494.00
QO130L200G
407.00 QOC30UF
QOC30US
87.00
PK23GTA, LK100ANl
200 A
30
40
10
554.00
QO13040L200G
467.00 QOC30UF
QOC30US
87.00
6–250
PK23GTA, LK100ANl
40
40
0
746.00
QO140L200G
659.00 QOC40UF
QOC40US
87.00
PK23GTA, LK100ANl
40
60
20
944.00
QO14060L200G
857.00 QOC40UF
QOC40US
87.00
(2) PK15GTAl
New!
42
52
10
921.00
QO14252L200G
810.00 QOC42UF
QOC42US
111.00
(2) PK15GTAl
225 A
42
42
0
828.00
QO142L225G
717.00 QOC42UF
QOC42US
111.00
6–300
PK23GTA, LK100ANl
Fixed Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Ratingbj
QONQ30LS400 (Int)
1080.00
(1) 1/0–750
400 A
30
30
0
1641.00
NC50NQVF NC50NQVS
486.00
33.80
MH50 (box)o
75.00
or (2) 1/0–300 PK27GTAn
or
QONQ42LS400 (Int)m
1185.00
(1) 1/0–750
PK15GTA6
53.00
400 A
42
42
0
1746.00
NC50NQVF NC50NQVS
486.00
MH50 (box)
75.00
or (2) 1/0–300
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b
UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
c
Will not accept QO-EPD or Qwik-Gard® QO-GFI or QO-AFI circuit breakers.
d
Mains rated 25 A when Al wire is used.
e
Order F for flush device or S for surface device.
f
Use 10 AWG maximum size wire for GFI and AFI circuit breakers.
g
70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker.
h
CU indicates copper bus.
i
Copper bus.
j
UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
k
Supplied with feed-thru lugs.
l
Factory-included.
m
Interior only, order box separately.
n
PK27GTA includes a 6–2/0 AWG Al/Cu lug.
o
PE1A Discount Schedule.
QO120L125G
1
2
4
4
4
LOAD CENTERS
Mains
Max. 1P
Rating Spaces Circuitsa
4
4
21
6
6
7
7
7
7
7
8
1
Table 1.16:
9
9
9
9
10
9
9
10
10
11
11
15
15
QO816L100F or S
without cover
Main Circuit Breaker Kits
Table 1.17:
Field-Installed Main Circuit Breaker (Use with Convertible Load Centers Only)
QOM1 Frame Size
QOM1 Frame Size
50–125 Amperes
p
q
r
QOM2 Frame Size
100–225 Amperes
© 2009 Schneider Electric
All Rights Reserved
s
QOM2 Frame Sizes
22 k AIRq
Lug Wire Sizer
Lug Wire Sizer
Main Circuit
Main Circuit
AWG/kcmil
AWG/kcmil
$
Price
$ Price
Breaker
Breaker
50 A
100–125
QOM50VH
140.00
100 A
150–225
QOM2100VH
468.00
60 A
100–125
QOM60VH
140.00
125 A
150–225
QOM2125VH
468.00
70 A
100–125
QOM70VH
140.00
150 A
150–225
QOM2150VH
468.00
4–300 Al or Cu
80 A
100–125
QOM80VH
201.00
175 A
200–225
QOM2175VH
468.00
12–2/0 Al or Cu
90 A
100–125
QOM90VH
201.00
200 A
200–225
QOM2200VH
468.00
100 A
100–125
QOM100VH
201.00
225 A
225
QOM2225VH
468.00
110 A
125
QOM110VH
468.00
125 A
125
QOM125VH
468.00
Do not exceed the load center mains rating.
22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems
with up to 22 kA available fault current.
Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center
per UL, see pages 1-5 through 1-11 under Main Wire Size.
Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00.
Main Circuit
Breaker
Ratingp
Convertible
Load Center
Mains Rating
22 k AIRq
DE3A
PE1A
Main Circuit
Breaker
Ratingp
Discount
Schedule
Convertible
Load Center
Mains Rating
1-5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® Load Centers
Indoor, 1Ø Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
1Ø3W—120/240 Vac—UL Listed
Table 1.18:
Mains
Rating
LOAD CENTERS
I
N
D
O
O
R
Indoor Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL Branch Circuit Breakers
from pages 1-2 and 1-3.)
Spaces
Max.
Single
Pole
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Indoor Cover with Door
(Order Separately)
Load Center
Box and Interior
Cat. No.
$ Price
Flush
Cat. No.
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating,
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),b
QOM1 Main Circuit Breaker Frame Size—Copper Bus
12
12
0
339.70
QO112M100
302.00
QOC12UF
16
16
0
379.70
QO116M100
342.00 QOC20U100F
100 A
20
20
0
433.70
QO120M100
396.00 QOC20U100F
24
24
0
553.70
QO124M100
516.00
QOC24UF
32
32
0
726.70
QO132M100
689.00
QOC32UF
24
24
0
819.70
QO124M125
782.00
QOC24UF
125 A
32
32
0
1041.60
QO132M125
1002.00
QOC32UF
Convertible Mains —Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5) b
QOM2 Main Circuit Breaker Frame Size—Copper Bus
20
30
10
821.00
QO12030M150
734.00
QOC30UF
24
24
0
849.00
QO124M150
762.00
QOC30UF
150 A
30
30
0
854.00
QO130M150
767.00
QOC30UF
32
32
0
969.00
QO132M150
882.00
QOC40UF
20
40
20
821.00
QO12040M200
734.00
QOC30UF
24
24
0
866.00
QO124M200
779.00
QOC30UF
Surface
Cat. No.
$ Price
QOC12US
QOC20U100S
QOC20U100S
QOC24US
Use Flush
QOC24US
Use Flush
37.70
37.70
37.70
37.70
37.70
37.70
39.60
QOC30US
QOC30US
QOC30US
QOC40US
QOC30US
QOC30US
87.00
87.00
87.00
87.00
87.00
87.00
24
Main
Wire Size
AWG/kcmil
Al or Cu
6–1
6–2/0
6–2/0
4–250
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page
1-17
Cat. No.
$ Price
PK9GTA
PK12GTA
PK15GTA
PK15GTA
PK18GTA
PK15GTA
PK18GTA
13.40
15.80
17.10
17.10
18.80
17.10
18.80
5
6
6
7
8
7
8
PK18GTA
PK15GTA
PK18GTA
PK18GTA
PK23GTA
PK15GTA
PK23GTA and
LK100ANg
PK18GTA
PK23GTA
PK23GTA
PK23GTA
PK23GTA
PK23GTA
PK23GTA
PK23GTA
18.80
17.10
18.80
18.80
21.30
17.10
9
9
9
10
9
9
36
12
1287.00 QO12436M200TFTh 1200.00
QOC40UF
QOC40US
87.00
10
4–250
QOC30UF
QOC30US
87.00
18.80
9
30
30
0
879.00
QO130M200
792.00
30
40
10
957.00
QO13040M200
870.00
QOC30UF
QOC30US
87.00
21.30
9
40
40
0
1121.00
QO140M200
1034.00
QOC40UF
QOC40US
87.00
21.30
10
40
60
20
1431.00
QO14060M200
1344.00
QOC40UF
QOC40US
87.00
21.30
10
42
42
0
1220.00
QO142M200
1109.00
QOC42UF
QOC42US
111.00
21.30
11
New!
42
52
10
1382.00
QO14252M200
1271.00
QOC42UF
QOC42US
111.00
21.30
11
4–300
40
40
0
1196.00
QO140M225
1085.00
QOC42UF
QOC42US
111.00
21.30
11
225 A
42
42
0
1253.00
QO142M225
1142.00
QOC42UF
QOC42US
111.00
21.30
11
Fixed Mains—Factory-installed LAL Main Circuit Breaker, 42 kA Short Circuit Current Ratingc
QONQ42MS300
4243.00
(1) 4–500
(int)d
300 A
42
42
0
4909.00
NC62NQVF
NC62NQVS
591.00
16
PK27GTAe
33.80
MH62 (box)f
75.00
or (2) 4–3/0
or
QONQ42MS400
PK15GTA6
53.00
4243.00
(1) 4–500
(int)d
NC62NQVF
NC62NQVS
591.00
16
400 A
42
42
0
4909.00
MH62 (box)f
75.00
or (2) 4–250
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b
22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
c
UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H
circuit breakers only.
d
Interior only, order box separately.
e
PK27GTA includes a 6–2/0 Al/Cu lug.
f
PE1A Discount Schedule.
g
Factory included.
h
Supplied with feed-thru lugs.
200 A
Main Lug Kits
Table 1.19:
Field-Installed Main Lugs (Convertible Load Centers Only)
Use on
Lug Wire Sizej
Convertible Load Center
Cat. No.
$ Price
AWG/kcmil
with Mains Rating
Al or Cu
125 A
100–125 A
QOL125k
44.10
6–2/0
225 A
150–225 A
QOL225k
104.00
6–300
i
Do not exceed the load center mains rating.
j
Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular
load center per UL, see pages 1-5 through 1-11 under main wire size.
k
If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from
page 1-13.
Main Lug
Ratingi
QOL125
QOL225
QO130M150
1-6
DE3A
PE1A
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® Load Centers
Rainproof 1Ø, Main Lugs, Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1Ø3W—120/240 Vac—UL Listed
Mains
Rating
Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 1-2 and 1-3.)
Spaces
Max.
Single Pole
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Main
Wire Size
AWG/kcmil
Load Center
Box and Interior
Cat. No.
$ Price
Equipment
Ground Bar Kit
(Order Separately)
Al
Cu
Cat. No.
$ Price
102.00
14–4
14–4
Factory-installed
113.00
131.00
143.00
158.00
231.00
174.00
279.00
152.00
12–6
12–3
14–6
14–4
PK3GTA1
PK4GTA
PK7GTA
Factory-installed
PK7GTA
PK7GTA
PK7GTA
PK7GTA Factory-included
Box No.
See
Page 1-17
Non-Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating
60 A
2
4
2
102.00
QO24L60NRNM
—
1NM
R
A
I
N
P
R
O
O
F
Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating
40 A
2
2
0
113.00
QO2L40RBb
70 A
2
4
2
131.00
QO24L70RBb
6
12
6
143.00
QO612L100RBc
100 A
6
12
6
158.00
QO612L100TRBc
8
16
8
231.00
QO816L100RBc
6
12
6
174.00
QO612L100RBCUcd
100 A
8
16
8
279.00
QO816L100RBCUcd
125 A
4
8
4
152.00
QO148L125GRBd
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
12
12
0
285.00
QO112L125GRB
12
24
12
365.00
QO11224L125GRB
125 A
16
24
8
435.00
QO11624L125GRB
24
24
0
522.00
QO124L125GRB
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg
QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
150 A
30
30
0
587.00
QO130L150GRB
12
12
0
480.00
QO112L200GRB
30
30
0
666.00
QO130L200GRB
30
40
10
714.00
QO13040L200GRB
200 A
40
40
0
971.00
QO140L200GRB
40
60
20
1262.00
QO14060L200GRB
New!
42
52
10
1194.00
QO14252L200GRB
225 A
42
42
0
1310.00
QO142L225GRB
285.00
365.00
435.00
522.00
587.00
480.00
666.00
714.00
971.00
1262.00
1194.00
1310.00
8–1
8–1
12–2/0
14–2/0
6–2/0
4–250
4–250
4–300
11.40
10.80
11.70
—
11.70
11.70
11.70
1R
1R
2R
2R
2R
2R
2R
15R
—
—
—
—
3R
3R
4R
4R
PK9GTA Factory-included
PK15GTA Factory-included
PK15GTA Factory-included
PK15GTA Factory-included
PK23GTA, LK100AN Factory-included
PK9GTA Factory-included
PK23GTA, LK100AN Factory-included
PK23GTA, LK100AN Factory-included
PK23GTA, LK100AN Factory-included
(2) PK15GTA, (1) LK100AN Factory-included
(2) PK15GTA, (1) LK100AN Factory-included
PK23GTA, LK100AN Factory-included
1
Metallic Enclosure
LOAD CENTERS
Table 1.20:
6R
5R
6R
6R
7R
7R
8R
8R
1Ø3W—120/240 Vac—UL Listed
Table 1.21:
Mains
Rating
R
A
I
N
P
R
O
O
F
Main Circuit Breaker Order QO, QOT, QO-GFI, QO-AFI, QO-EPD and QO-PL branch circuit breakers from pages 1-2 and 1-3.
Spaces
Max.
Single Pole
Circuits a
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Cat. No.
$ Price
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
—Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg
QOM1 Main Circuit Breaker Frame Size—Copper Bus
12
12
0
461.00
QO112M100RB
461.00
100 A
16
16
0
504.00
QO116M100RB
504.00
20
20
0
552.00
QO120M100RB
552.00
125 A
24
24
0
954.00
QO124M125RB
954.00
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
—Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg
QOM2 Main Circuit Breaker Frame Size—Copper Bus
20
30
10
953.00
QO12030M150RB
953.00
150 A
30
30
0
1122.00
QO130M150RB
1122.00
20
40
20
954.00
QO12040M200RB
954.00
30
30
0
1154.00
QO130M200RB
1154.00
30
40
10
1179.00
QO13040M200GRB
1179.00
200 A
40
40
0
1397.00
QO140M200RB
1397.00
40
60
20
1815.00
QO14060M200RB
1815.00
42
42
0
1469.00
QO142M200RB
1469.00
New!
42
52
10
1718.00
QO14252M200RB
1718.00
225 A
42
42
0
1631.00
QO142M225RB
1631.00
QOM1/QOM2 Feed-Thru Main Circuit Breaker With Feed-Thru Lugs—Copper Bus, 22 kA Short Circuit Current Rating h
125 A
6
12
6
620.00
QO1612M125FTRBi
620.00
150 A
8
16
8
863.00
QO1816M150FTRBi
863.00
200 A
8
16
8
863.00
QO1816M200FTRB i
863.00
Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately)
Cat. No.
$ Price
Box No.
See
Page 1-17
PK9GTA
PK12GTA
PK15GTA
PK15GTA
13.40
15.80
17.10
17.10
3R
4R
4R
4R
4–300
PK18GTA
PK18GTA
PK23GTA
PK18GTA
PK23GTA
PK23GTA
PK15GTA
PK23GTA
PK15GTA
PK23GTA
18.80
18.80
21.30
18.80
21.30
21.30
17.10
21.30
17.10
21.30
5R
6R
5R
6R
6R
7R
7R
8R
8R
8R
4–2/0
4–250
4–250
PK12GTA
PK15GTA-L
PK15GTA-L
15.80
35.00
35.00
3R
6R
6R
6–2/0
6–2/0
4–250
4–250
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b
Use 10 AWG maximum size wire for AFI and GFI circuit breaker.
c
70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
d
Copper bus.
e
UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed.
f
UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
g
Side hinge door device; allow 1-1/4 in. on left side for door to open.
h
22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22
kA available fault current.
i
QO1612M125FTRB provided with QOM1 frame main circuit breaker. QO1816M150FTRB and QO1816M200FTRB provided with QOM2 frame main circuit breaker.
© 2009 Schneider Electric
All Rights Reserved
DE3A
Discount
Schedule
1-7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® Load Centers
3Ø, Main Lugs, Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
Table 1.22:
3Ø4W 208Y/120 Vac, 3Ø4W 240/120 Vac Delta and 3Ø3W 240 Vac Delta, UL Listed.
(Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 1-2 and 1-3.)
Mains
Rating
LOAD CENTERS
I
N
D
O
O
R
Max.
Number
of 1P QO
circuit
breakers
$ Price
(Interior,
Box and
Cover)
Indoor Cover with Door
(Order Separately)
Load Center
Box and Interior
Cat. No.
Flush
Cat. No.
$ Price
Surface
Cat. No.
Main
Wire Size
AWG/kcmil
$ Price
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating a
60 A
3
107.00
QO403L60NF/S
107.00 Cover Included With Load Center (No Door)
12
369.70
QO312L125Gh
332.00
QOC16UF
QOC16US
37.70 i
125 A
20
508.70
QO320L125Gh
471.00
QOC24UF
QOC24US
37.70 i
24
577.70
QO324L125Gh
540.00
QOC24UF
QOC24US
37.70 i
18
530.00
QO318L200Gh
443.00
QOC30UF
QOC30US
87.00 i
200 A
30
707.00
QO330L200Gh
620.00
QOC30UF
QOC30US
87.00 i
225 A
42
953.00
QO342L225Gh
842.00
QOC42UF
QOC42US
111.00 i
Equipment
Ground Bar Kit
(Order Separately)
Al
Cu
Cat. No.
—
10–6
6–2/0
6–2/0
PK4GTA
Factory-incl.g
Factory-incl.g
Factory-incl.g
Factory-incl.f
Factory-incl.f
Factory-incl.f
7.20
—
—
—
—
—
—
13
6
7
7
9
9
11
PK15GTA
PK18GTA
PK18GTA
PK23GTA
PK18GTA
PK23GTA
PK23GTA
17.10
18.80
18.80
21.30
18.80
21.30
21.30
9
12
12
12
12
12
12
6–250
6–250
6–300
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating b
100 A
27
1058.00
QO327M100c
971.00
QOC30UF
QOC30US
87.00 i
4–2/0
125 A
30
1931.00 QO330MQ125dh
1839.00 QOC342MQF QOC342MQS
92.00
4–300
30
1931.00 QO330MQ150dh
1839.00 QOC342MQF QOC342MQS
92.00
150 A
4–300
42
2119.00 QO342MQ150dh
2027.00 QOC342MQF QOC342MQS
92.00
30
1931.00 QO330MQ200dh
1839.00 QOC342MQF QOC342MQS
92.00
200 A
4–300
42
2119.00 QO342MQ200dh
2027.00 QOC342MQF QOC342MQS
92.00
225 A
42
2119.00 QO342MQ225dh
2027.00 QOC342MQF QOC342MQS
92.00
4–300
6–300
4–2/0
4–300
4–300
4–300
4–300
$ Pricej
Box No.
See
Pages
1-17
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratingae
60 A
3
177.00
QO403L60NRB
177.00
—
10–6
PK4GTA
10.80
10R
12
485.00 QO312L125GRB
485.00
Factory Incl.g
—
3R
6–2/0
6–2/0
20
629.00 QO320L125GRB
629.00
Factory Incl.g
—
4R
R
Cover Included
18
618.00 QO318L200GRB
618.00
Factory Incl.f
—
6R
A
200 A
6–250
6–250
I
30
839.00 QO330L200GRB
839.00
Factory Incl.f
—
6R
N
225 A
42
1494.00 QO342L225GRB
1494.00
6–300
6–300
Factory Incl.f
—
8R
P
R Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingb e
O
100 A
27
1185.00 QO327M100RBc
1185.00
4–2/0
4–2/0
PK15GTA
17.10
6R
O
125 A
30
2147.00 QO330MQ125RBd
2147.00
4–300
4–300
PK18GTA
18.80
14R
F
150 A
30
2147.00 QO330MQ150RBd
2147.00
4–300
4–300
PK18GTA
18.80
14R
Cover Included
30
2147.00 QO330MQ200RBd
2147.00
PK18GTA
18.80
14R
200 A
4–300
4–300
42
2333.00 QO342MQ200RBd
2333.00
PK23GTA
21.30
14R
225 A
42
2333.00 QO342MQ225RBd
2333.00
4–300
4–300
PK23GTA
21.30
14R
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
a
UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b
25 kA short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k AIR
branch circuit breakers.
c
Includes factory-installed back fed QO3100VH main circuit breaker.
d
65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers.
e
Side hinge door device allow 1-1/4 in. on left side for door to open.
f
PK23GTA and LK100AN.
g
PK15GTA.
h
For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating
when QODX...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used).
i
DE3A Discount Schedule
j
DE2 Discount Schedule
125 A
Table 1.23:
3Ø Main Circuit Breakers
Field-installed alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A. Do not exceed the
load center main rating.
k
Amperage
25 k AIR
65 k AIR
100 k AIRk
70 A
QDL32070
QGL32070
QJL32070
80 A
QDL32080
QGL32080
QJL32080
90 A
QDL32090
QGL32090
QJL32090
100 A
QDL32100
QGL32100
QJL32100
110 A
QDL32110
QGL32110
QJL32110
125 A
QDL32125
QGL32125
QJL32125
150 A
QDL32150
QGL32150
QJL32150
175 A
QDL32175
QGL32175
QJL32175
200 A
QDL32200
QGL32200
QJL32200
225 A
QDL32225
QGL32225
QJL32225
$ Price (DE2)
1784.00
2442.00
2796.00
When these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating
is 65 kA at 240 Vac and 100 kA at 208 Vac.
Table 1.24:
3Ø Main Lug Kits
Field-installed main lugs for convertible 3Ø main circuit breaker load centers.
QO342MQ200
1-8
QO312L125G
Main Lug
Amperage Rating
125 A
225 A
DE3
DE3A
DE2
Cat. No.
QOL3125
QOL3225
Discount
Schedule
$ Price
67.00
158.00
Lug Wire Size
AWG/kcmil
6–2/0 Cu/Al
6–300 Cu/Al
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® and Homeline® Load Centers
Backup Power Solutions
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
Order QO, QOT, QO-EPD, QO-GFI, and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.
Mains
Max. Single
Rating Spaces
Pole
(A)
Circuits a
R
A
I
N
P
R
O
O
F
Load Center
Box, Interior and Cover
Cat. No.
Main
Wire Size
AWG/kcmil
$ Price
Cat. No.
$ Price
Generator Panels for Sub-Feed Applications Type 1 (Indoor)
1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating
30
4
8
4
QO48M30DSGP
563.00
60
4
8
4
QO48M60DSGP
Al
Cu
Box No.
See
Page
1-12
14–8
14–8
4
8–2
8–2
4
Equipment Grounding Bar Kit
(Order Separately)
563.00
PK7GTA
11.70
Generator Panels with Power Inlet Plug for Sub-Feed Applications Type 3R (Outdoor)
1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating
4
8
4
QO1DM10020TRBR
848.00
4
8
4
QO1DM10030TRBR
848.00
100
—
—
Factory-Installed
4
8
4
QO1DM10050TRBR
—
—
8–2
1148.00
—
—
1
I
N
D
O
O
R
Max.
Tandem Circuit
Breakers
LOAD CENTERS
Table 1.25:
Generator Panel—Automatic Transfer Switch (Contact your local Square D Field Sales office for more information.) b
1-Phase 3-Wire 120/240 Vac Factory- or Field-Installed Main Circuit Breaker 22,000 RMS Sym. Ampere Short Circuit Current Rating
150
38
42
42
QO13842MX150
1349.00
PK23GTA
21.30
4–250
4–250
12
200
38
42
42
QO13842MX200
1499.00
PK23GTA
21.30
4–250
4–250
12
I
N
38
42
42
QO13842MX225
1649.00
4–250
4–250
12
225
PK23GTA
21.30
D
38
42
42
QO13842UX225 c
1199.00
4–250
4–250
12
O
QOC38MXUF (Cover)
149.00
—
O
R
150
14
28
28
QO11428MX150FTRBde
1349.00
PK23GTA
21.30
4–250
4–250
7R
14
28
28
QO11428MX200FTRBde
1499.00
PK23GTA
21.30
4–250
4–250
7R
200
14
28
28
QO11428UX200FTRBcde
1199.00
PK23GTA
21.30
4–250
4–250
7R
QO Load Center Accessories
Cat. No.
$ Price
Schedule
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that
QO2DTI
24.90
DE2E
only one circuit breaker can be “ON’’ at a time.
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual
QO2DTIM
63.00
DE2E
power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers.
Secures
two
2P
circuit
breakers
to
right
side
of
interior
when
used
as
back-fed
mains,
a
QO2DTI
Kit
included
for
backManual Transfer Equipment Kit up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02.
PK4DTIM4LA
102.00
DE3A
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back- PK4DTIM4HA
102.00
DE3A
up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02.
Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up PK4DTIM4LAL
102.00
DE3A
power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02.
For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P QOCRBGK1
105.00
DE3A
main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit.
Generator Circuit Breaker
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main
QOCGK2
105.00
DE3A
circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit.
Interlock Kit
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) QORBGK2
105.00
DE3A
with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b
One main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max.) ordered separately. Automatic
Transfer Switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor.
c
Universal mains – No factory-installed main circuit breaker or main lugs. QOM2 frame size, field-install 22 k AIR. Main circuit breaker or main lugs (see pages 1-5 or 1-6).
d
Supplied with feed-thru lugs.
e
Device is rated NEMA 3R and can be used for indoor or outdoor applications.
QO2DTI Installed
QO2DTI
ON
OFF
ON
OFF
1
3
ON
OFF
5
ON
OFF
PK4DTIM4HA
QOCGK2 Installed
© 2009 Schneider Electric
All Rights Reserved
DE3A
Discount
Schedule
1-9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® Load Centers
Special Applications
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
Table 1.26:
Mains
Rating
QO Special Application (Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.)
Short Circuit
Current
Rating
Max. 1P
Circuits a
Spaces
Load Center b
Box, Interior, and Cover
Max. Tandem
Circuit
Breakers
Cat. No.
0
2
QO2L30TTSd
QO24L50TTSe
LOAD CENTERS
Manufactured Housing:
1Ø2W 120 Vac—Main Lugs Only—CSA Certified
30 Ac
10 kA
2
2
4
50 A
10 kA
2
Equipment Ground Bar Kit
(Order Separately)
$ Price
Cat. No.
51.00
78.00
Main Wire Size
AWG/kcmil
Al
Cu
Box No.
See
Page 1-17
12–10
—
14–10
14–6
1
2
$ Price
Factory-installed
1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified
30 A
10 kA
3
5
2
QO35FM30TTF/S
83.00
Factory-installed
1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified
70 A
10 kA
2
4
2
QO24L70TSe
78.00
10 kA
6
12
6
QO612L100TF/Sg
86.00
Factory
10 kA
6
12
6
QO612L100DTF/Sg
101.00
Installed
100 A
10 kA
8
16
8
QO816L100TF/Sg
137.00
10 kA
8
16
8
QO816L100DTF/Sg
159.00
Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package
I
N
D
O
O
R
f
3
12–3
14–4
2
4
4
4
4
4–1
Convertible Mains—Factory-Installed Main Lugs i—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
65 kA
12
0
QO112L125GC
188.00
PK12GTA Incl.
12
125 A
65 kA
12
24
12
QO11224L125GC
249.00
PK15GTA Incl.
20
65 kA
20
0
QO120L125GC
284.00
PK15GTA Incl.
Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
150 A
65 kA
30
30
0
QO130L150TC
452.00 PK23GTA, LK100AN Installed
200 A
65 kA
30
40
10
QO13040L200GC
575.00 PK23GTA, LK100AN Incl.
6–2/0
6–2/0
6–2/0
6
6
7
6–250
6–250
9
9
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
22 kA
12
12
0
QO112M100C
351.00
PK9GTA
13.40
4–1/0
5
22 kA
12
20
8
QO11220M100C
413.00
PK15GTA
17.10
4–1/0
5
100 A
22 kA
16
16
0
QO116M100C
395.00
PK12GTA
15.80
4–1/0
6
22 kA
20
20
0
QO120M100C
446.00
PK15GTA
17.10
4–1/0
6
125 A
22 kA
32
32
0
QO132M125C
1041.00
PK18GTA
18.80
6–2/0
8
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
22 kA
20
30
10
QO12030M150C
843.00
PK18GTA
18.80
4–250
9
150 A
22 kA
30
30
0
QO130M150C
870.00
PK18GTA
18.80
4–250
9
22 kA
20
40
20
QO12040M200C
843.00
PK23GTA
21.30
4–250
9
22 kA
30
30
0
QO130M200C
896.00
PK18GTA
18.80
4–250
9
200 A
22 kA
30
40
10
QO13040M200C
974.00
PK23GTA
21.30
4–250
9
22 kA
40
40
0
QO140M200C
1137.00
PK23GTA
21.30
4–250
10
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b
Order F for flush device or S for surface device.
c
Mains rating 25 A when Al wire is used.
d
Will not accept Qwik-Gard® QO-GFI or QO-AFI circuit breaker.
e
Use 10 AWG maximum size wire for GFI and AFI circuit breakers.
f
Main circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2.
g
70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
h
UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
i
UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
j
22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current.
Table 1.27:
Auxiliary Gutter
UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsk. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501
k
l
Cat. No.
$ Price
SDAG26
338.00
One tap kit required for each riser wire.
When used with B300 bolt-on hubs.
Table 1.28:
Cover
Flush
Width
13.50
Height
26.12
Depth
3.75
Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26
Cat. N0.
$ Price
Use with Auxiliary
Gutter Cat. No.
SDGT30020
SDGT300300
81.00
120.00
SDAG26
SDAG26
SDGT300C10C
49.70
SDAG26
SDGT300C300C
70.00
SDAG26
QOGL20 Grounding Terminals
40.70
SDAG26
1-10
Conduit Riser Size
1-3/4, 2, 2-1/2 or l3
Riser Wire
Lug Type
Mechanical (Included)
Mechanical (Included)
Anderson VCEL030516H1
(Not included)
Anderson VCEL030516H1
(Not included)
Mechanical (Included)
DE3A
Discount
Schedule
Tap Off Wire
Al/Cu Wire Size
(2) 6 AWG–300 kcmil
(2) 6 AWG–300 kcmil
(2) 4 AWG–300 kcmil
(2) 4 AWG–300 kcmil
(2) 6–2/0 AWG
Lug Type
Mechanical (Included)
Mechanical (Included)
Anderson VCEL02114S1
(Not Included)
Anderson VCEL030516H1
(Not included)
—
Al/Cu Wire Size
(1) 6–2/0 AWG
(1) 6 AWG–300 kcmil
(1) 8–1/0 AWG
(1) 4 AWG–300 kcmil
—
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® and Homeline® Load Centers
Load Center Value Pack
Class 1130, 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
Load Center Value Pack
I
N
D
O
O
R
R
A
I
N
P
R
O
O
F
Max.
Tandem
Circuit
Breakers
Equipment
Ground Bar Kit
(Order Separately)
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Cat. No.
Included Load Center/Circuit Breakers
$ Price
QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 1-2 and 1-3.
Main Circuit Breaker
100 A
32
32
0
QOVP2
(1) QO132M100C, (5) QO120
200 A
30
40
10
QOVP1
(1) QO13040M200C, (5) QO120
200 A
30
40
10
QOVP10
(1) QO13040M200C, (10) QO120
Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14.
Main Lugs
125 A
12
24
12
HOMVPL2 (1) HOM1224L125TC, (5) HOM120
200 A
30
40
10
HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250
Main Circuit Breaker
100 A
20
20
0
HOMVP4
(1) HOM20M100C, (5) HOM115
100 A
20
20
0
HOMVP5
(1) HOM20M100C, (5) HOM120
150 A
30
30
0
HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230
200 A
20
40
20
HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230
200 A
30
40
10
HOMVP1
(1) HOM3040M200TC, (5) HOM120, (1) HOM230
200 A
30
40
10
HOMVP2
(1) HOM3040M200TC, (5) HOM115, (1) HOM230
200 A
30
40
10
HOMVP9
(1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250
200 A
30
40
10
HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250
200 A
40
40
0
HOMVP15 (1) HOM40M200C, (10) HOM120
Cat. No.
839.00
1103.00
1328.00
PK18GTA
PK23GTA
PK23GTA
353.00
962.00
Included
Included
528.00
528.00
983.00
965.00
1083.00
1083.00
1328.00
1328.00
1346.00
PK15GTA
PK15GTA
PK23GTA
Included
Included
Included
Included
Included
PK23GTA
1253.00
PK23GTA
Main
Wire Size
AWG/kcmil
Al/Cu
$ Price
18.80
21.30
21.30
Box No.
See
Pages
1-17
4–2/0
4–250
4–250
8
9
9
6–2/0
4–250
6
10
17.10
17.10
21.30
—
—
—
—
—
21.30
4–2/0
4–2/0
4–250
4–250
4–250
4–250
4–250
4–250
4–250
7
7
10
9
10
10
10
10
12
21.30
4–250
6R
—
—
LOAD CENTERS
Max.
1P
Circuitsa
1
Mains
Rating
1Ø3W—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker
Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers
Spaces
Table 1.29:
Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14.
Main Circuit Breaker
200 A
20
40
20
HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
Riser Panels
Table 1.30:
Mains
Rating
1Ø3W 120/240 Vac—Offset Interior Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interior bc
Spaces
Max.
Single
Pole
Circuitsd
Max.
Tandem
Circuit
Breakers
Load Center Box and Interior
Cat. No.
$ Price
Load Center Cover
Cat. No.
$ Price
Equipment
Ground Bar Kit
(Order Separately)
Cat. No.
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
125 A
12
24
12
QO11224L125WG
338.00 QOC20UFWG
53.00
PK15GTA
I
125 A
20
30
10
QO12030L125WG
465.00 QOC20UFWG
53.00
PK15GTA
N
D Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating
O QOM2 Main Frame Size–Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below–Copper Bus
O
200 A
30
40
10
QO13040L200WG
701.00 QOC30UFWG
102.00
PK23GTA
R
Convertible Mains—Factory-installed Main Circuit Breaker—22 kA Short Circuit Current Rating
QOM2 Main Frame Size–Convertible to Main Lugs (See page 1-6)—Copper Bus
200 A
24
24
0
QO124M200WG125e
683.00 QOC30UFWG
102.00
PK23GTA
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
b
UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
c
UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
d
Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
e
Comes with 125 A main circuit breaker factory installed.
Main
Wire Size
AWG/kcmil
$ Price
Al
Cu
Box No.
See
Page 1-17
17.10
17.10
6–2/0
6–2/0
14
14
21.30
4–250
23
21.30
4–250
23
Panelboard-style Covers for Riser Panels
Mono-Flat® Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing
solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used
when panel has been converted to a main circuit breaker panel. f
f
Mains Rating of Load Center
Cat. No.
125 A
NQC20FWG
200 A
NQC30FWG
Order catalog number PK4FL for field-installed lock kit.
© 2009 Schneider Electric
All Rights Reserved
$ Price
117.00
180.00
DE3A
Discount
Schedule
1-11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Load Center Accessories
QO Load Center Accessories
Class 1130 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
Table 1.31:
Retaining Kit
LOAD CENTERS
Miscellaneous
QO Load Center Accessories
Description
Cat. No.
Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB,
PK2MB
QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers
Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3Ø load centers
PK3MB
Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers.
PK5RK
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2LA
For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02.
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2HA
For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02.
Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers
QO1SE
For use on 1Ø3W, 150 Vac maximum
SDSA1175
For use on 3Ø4W, 650 Vac maximum
SDSA3650
Surge Arresters:
QO Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum.
QO2175SB
HOM2175SB
Homeline Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum.
Surge Arrester
UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker
QOSAMK
Mounting Kit:
load centers
Replacement Cover 1 through 42 numbered universal replacement directory label for load center covers
LSDL
Directory Label:
Circuit Identification Circuit identification stickers for use on cover directory labels to identify branch circuits
PSDS
Stickers:
$ Price Schedule
7.20
DE3A
14.70
14.70
DE3A
DE3A
14.70
DE3A
14.70
DE3A
3.60
92.00
248.00
159.00
159.00
DE3A
DE1B
DE1B
DE1B
DE1B
11.40
DE3A
0.54
DE5
0.75
DE5
PK2MB
QOSAMK
PK3MB
1-12
DE1B
DE2E
DE3A
DE5
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® and Homeline® Accessories and Voltage testers
Load Center Accessories
Class 1130, 6610 / Refer to Catalog 1100CT0501
www.schneider-electric.us
Description
Fills opening in covers if twistout is removed in error
Fills main circuit breaker opening in convertible load center covers100–125 A
Filler Plates
Fills main circuit breaker opening in convertible load center covers150–225 A
Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series)
Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series)
Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU,
QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP.
Lock Kits
Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers
Use with 300 and 400 ampere indoor load centers.
Field-installed for 12– 2 Al or 14–4 Cu AWG wire
Field-installed for 6–2/0 Al/Cu AWG wire
Neutral / Ground Lugs
Field-installed for 14–2/0 Al/Cu AWG wire
Field-installed for 2–3/0 Al/Cu AWG wire
Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center
Standard PK15GTA with a 1–4/0 Al/Cu Lug
Standard PK18GTA with a 1–4/0 Al/Cu Lug
Ground Bar Kits
Standard PK23GTA with a 1–4/0 Al/Cu Lug
Insulator Kit for PK7GTA through PK27GTA
For padlocking main circuit breakers in convertible load centers OFF..........50–125 A, QOM1 Frame Size
Handle Padlock Attachment:
For padlocking main circuit breakers in convertible load centers OFF..........100–225 A, QOM2 Frame Size
a
QO403L60NF/S does not have provisions for a field-installed lock.
Cat. No.
QOFP
QOM1FP
QOM2FP
KFP
Q2FP
$ Price Schedule
3.60 DE3A
20.30 DE3A
20.30 DE3A
20.30 DE3A
20.30 DE3A
PK8FLa
98.00
DE3A
PK6FL
PK4FL
LK70AN
LK100AN
LK125AN
LK150AN
LK225AN
PK15GTAL
PK18GTAL
PK23GTAL
PKGTAB
QOM1PA
QOM2PA
93.00
90.00
10.10
10.80
22.10
32.40
33.20
35.00
37.80
40.70
43.80
11.00
11.00
DE3A
PE1A
DE3A
DE3A
DE3A
DE3A
DE3A
DE3A
DE3A
DE3A
DE3A
DE2E
DE2E
LOAD CENTERS
QO Load Center Accessories
1
Table 1.32:
QOFP
PKGTAB
PK4FL
PK6FL and PK8FL
Table 1.33:
Homeline Load Center Accessories
Description
Handle Padlock Attachment:
50–125 A
100–225 A
For padlocking main circuit breakers in convertible load center, “OFF”
Fills opening in covers if twistout is removed in error
Filler Plates
Neutral Lugs
Retaining Kit
Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire
Field-installed for 6–2/0 AWG Al/Cu wire
Field-installed for 14–2/0 AWG Al/Cu wire
Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center
Secures circuit breaker to interior when used as a back-fed main.
For HOM612L100F/S, RB and HOM48L125GC, GRB load centers.
Secures ONE circuit breaker right side of interior when used as a back-fed main.
For 100–125 A convertible main load centers, Series S01 and S02
Secures ONE circuit breaker right side of interior when used as a back-fed main.
For 150–225 A convertible main load centers, Series S01 and S02
Secures circuit breaker to interior when used as a back-fed main.
For 2P 150–200 A circuit breakers
$ Price Schedule
11.00 DE2E
11.00 DE2E
3.20 DE3C
20.30 DE3A
20.30 DE3A
10.10 DE3B
10.80 DE3B
22.10 DE3B
33.20 DE3A
HOM1RK
6.50
DE3C
HOM4RK2LA
14.70
DE3C
HOM4RK2HA
14.70
DE3C
HOM5RK
14.70
DE3C
Lock Kit
Use with convertible indoor load center covers (Series S-1)
PK6FL
93.00
DE3A
Replacement Cover
Directory Label
1 through 42 numbered universal replacement directory label for load center covers
LSDL
0.54
DE5
PSDS
0.75
DE5
Miscellaneous
Generator Circuit
Breaker Interlock Kit
100–125 A
150–225 A
Fills main circuit breaker opening in convertible load centers
Cat. No.
QOM1PA
QOM2PA
HOMFP
QOM1FP
QOM2FP
LK70AN
LK100AN
LK125AN
LK225AN
Circuit Identification
Circuit identification stickers for use on cover directory labels to identify branch circuits
Stickers:
For use on “S” Series NEMA 1 and “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main
circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker.
For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker
of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker.
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center
(150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker.
© 2009 Schneider Electric
All Rights Reserved
DE2E
DE3A
DE3B
DE3C
DE3D
DE3E
DE5
PE1A
Discount
Schedule
HOMCRBGK1
105.00
DE3D
HOMCGK2
105.00
DE3D
HOMRBGK2
105.00
DE3D
1-13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Homeline® Load Centers
Indoor, 1Ø, Main Lug, Main Circuit Breaker
Class 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
Mains
Rating
1Ø3W—120/240 Vac—UL Listed—10 kA Short Circuit Current Rating
Spaces
Max.
Single
Pole
Circuits a
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover b
Main Wire Size
AWG/kcmil
$ Price
(DE3C)
Cat. No.
Al
Cu
Equipment Ground Bar Kit
(Order Separately)
Cat. No.
$ Price
(DE3A)
Box No.
See
Page 1-17
LOAD CENTERS
Table 1.43:
Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 1-14
I
N
D
O
O
R
59.00
78.00
86.00
12–3
14–4
8–1
12–2/0
132.00
150.00
174.00
204.00
260.00
237.00
288.00
344.00
375.00
396.00
357.00
575.00
417.00
420.00
464.00
479.00
618.00
671.00
839.00
804.00
732.00
14–2/0
6–2/0
PK3GTA1
11.40
PK7GTA
11.70
PK7GTA Factory-included
PK15GTA
Factory-installed
PK15GTA
Factory-installed
PK15GTA
PK15GTA
Factory-installed
Factory-installed
17.10
—
17.10
—
17.10
17.10
—
—
4–250
4–250
PK23GTA
Factory-installed
—
4–250
Factory-installed
—
4–250
6–250
PK23GTA
Factory-installed
Factory-installed
PK23GTA
Factory-installed
Factory-installed
Factory-installed
PK23GTA
21.30
21.30
—
—
21.30
—
—
—
21.30
2
4
21
6
6
6
6
8
8
8
8
1
Factory-installed Fixed Main Lugs
70 A
2
4
2
HOM24L70F/Sdc
100 A
6
12
6
HOM612L100F/Sce
125 A
4
8
4
HOM48L125GC
Convertible Mains—Factory-installed Main Lugs
QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16)
8
16
8
HOM816L125C
8
16
8
HOM816L125TC
12
12
0
HOM12L125C
12
24
12
HOM1224L125TC
125 A
16
24
8
HOM1624L125C
20
20
0
HOM20L125C
20
24
4
HOM2024L125TC
24
24
0
HOM24L125TC
Convertible Mains—Factory-installed Main Lugs
QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16)
30
30
0
HOM30L150C
150 A
30
30
0
HOM30L150TC
16
32
16
HOM1632L200TC
200 A
16
32
16
HOM1632L200TCFTf
20
40
20
HOM2040L200TC
30
30
0
HOM30L200C
30
30
0
HOM30L200TC
30
40
10
HOM3040L200TC
200 A
40
40
0
HOM40L200C
40
40
0
HOM40L200TC
40
60
20
HOM4060L200TC
New!
42
52
10
HOM4252L200TC
225 A
42
42
0
HOM42L225C
10
10
9
10
9
10
10
10
12
12
12
12
12
Main Circuit Breaker—22 kA Short Circuit Current Rating
Convertible Mains—Factory-installed Main Circuit Breaker
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
8
16
8
HOM816M100C
315.00
8
16
8
HOM816M100TC
333.00
12
12
0
HOM12M100C
294.00
100 A
12
24
12
HOM1224M100TC
384.00
20
20
0
HOM20M100C
396.00
24
24
0
HOM24M100C
513.00
30
30
0
HOM30M100C
672.00
12
24
12
HOM1224M125C
606.00
12
24
12
HOM1224M125TC
620.00
125 A
24
24
0
HOM24M125C
710.00
30
30
0
HOM30M125C
812.00
Convertible Mains—Factory-installed Main Circuit Breaker
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
16
32
16
HOM1632M150TC
636.00
150 A
20
30
10
HOM2030M150TC
750.00
30
30
0
HOM30M150C
776.00
12
24
12
HOM1224M200TC
572.00
16
32
16
HOM1632M200TC
675.00
20
40
20
HOM2040M200C
711.00
20
40
20
HOM2040M200TC
764.00
30
30
0
HOM30M200C
798.00
200 A
30
40
10
HOM3040M200TC
891.00
40
40
0
HOM40M200C
1019.00
40
60
20
HOM4060M200C
1367.00
42
42
0
HOM42M200C
1094.00
New!
42
52
10
HOM4252M200C
1313.00
225 A
42
42
0
HOM42M225C
1116.00
6–1
6–1
6–2/0
6–2/0
6–1
6–2/0
6–2/0
6–2/0
4–250
4–250
4–250
PK15GTA
Factory-installed
PK15GTA
Factory-installed
PK15GTA
PK15GTA
PK23GTA
PK15GTA
Factory-installed
PK15GTA
PK23GTA
Factory-installed
Factory-installed
PK23GTA
Factory-installed
Factory-installed
PK23GTA
Factory-installed
PK23GTA
Factory-installed
PK23GTA
PK23GTA
PK23GTA
PK23GTA
PK23GTA
17.10
—
17.10
—
17.10
17.10
21.30
17.10
—
17.10
21.30
—
—
21.30
—
—
21.30
—
21.30
—
21.30
21.30
21.30
21.30
21.30
5
5
6
6
7
8
10
6
6
8
10
9
9
10
9
9
9
9
10
10
12
12
12
12
12
Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs
QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See page 1-16)
16
32
16
HOM1632U200TC
293.00
200 A
20
40
20
HOM2040U200TC
357.00
4–250
30
40
10
HOM3040U200TC
530.00
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
b
C at end of catalog number indicates combination flush/surface cover included with device.
c
F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
d
HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
e
70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
f
Supplied with feed-thru lugs.
© 2009 Schneider Electric
All Rights Reserved
DE3A
DE3C
Discount
Schedule
Factory-installed
Factory-installed
Factory-installed
—
—
—
9
9
10
1-15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Homeline® Load Centers
Rainproof, 1Ø, Main Lug, Main Circuit Breakers
Class 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
1
Table 1.44:
1Ø3W 120/240 Vac UL Listed Load Centers
Mains Rating
Spaces
Max. Single
Pole
Circuits a
Max. Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover
Cat. No. (DE3C)
Main Wire Size
AWG/kcmil
$ Price
Al
Cu
Equipment Ground Bar Kit
(Order Separately)
Cat. No. (DE3A)
$ Price
Box No.
See
Page 1-17
Main Lugs (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 10 kA Short Circuit Current Rating
LOAD CENTERS
R
A
I
N
P
R
O
O
F
Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating
70 A
2
4
2
HOM24L70RBb
111.00
12–3
14–4
PK4GTA
10.80
100 A
6
12
6
HOM612L100RBf
129.00
8–1
PK7GTA
11.70
125 A
4
8
4
HOM48L125GRB
137.00
12–2/0
14–2/0
PK7GTA Factory-included
Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below)
8
16
8
HOM816L125RB
248.00
PK15GTA
17.10
12
12
0
HOM12L125RB
234.00
PK15GTA
17.10
125 A
6–2/0
12
24
12
HOM1224L125RB
278.00
PK15GTA
17.10
20
20
0
HOM20L125RB
383.00
PK15GTA
17.10
Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below)
12
12
0
HOM12L200RB
423.00
PK23GTA
21.30
20
40
20
HOM2040L200RB
560.00
PK23GTA
21.30
30
30
0
HOM30L200RB
587.00
PK23GTA
21.30
200 A
30
40
10
HOM3040L200RB
759.00
—
—
4–250
40
40
0
HOM40L200RB
911.00
PK23GTA
21.30
New!
1R
2R
15R
3R
3R
3R
4R
5R
6R
7R
—
14R
40
60
20
HOM4060L200RB
1139.00
PK23GTA
21.30
14R
42
52
10
HOM4252L200RB
1092.00
PK23GTA
21.30
14R
Main Circuit Breaker (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 22 kA Short Circuit Current Rating
Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d
8
16
8
HOM816M100RB
429.00
6–1
PK15GTA
17.10
3R
12
12
0
HOM12M100RB
416.00
PK15GTA
17.10
3R
100 A
20
20
0
HOM20M100RB
531.00
6–2/0
PK15GTA
17.10
4R
24
24
0
HOM24M100RB
606.00
PK15GTA
17.10
6R
8
16
8
HOM816M125RB
716.00
PK15GTA
17.10
3R
125 A
6–2/0
24
24
0
HOM24M125RB
858.00
PK15GTA
17.10
6R
Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
150 A
30
30
0
HOM30M150RB
978.00
4–250
PK23GTA
21.30
7R
R
20
40
20
HOM2040M200RB
872.00
PK23GTA
21.30
6R
A
30
30
0
HOM30M200RB
1004.00
PK23GTA
21.30
7R
I
N
30
40
10
HOM3040M200RB
1152.00
PK23GTA
21.30
7R
200 A
4–250
P
40
40
0
HOM40M200RB
1277.00
PK23GTA
21.30
14R
R
40
60
20
HOM4060M200RB
1596.00
PK23GTA
14.20
14R
O
New!
O
42
52
10
HOM4252M200RB
1532.00
PK23GTA
14.20
14R
F
16
24
8
HOM1624M225RB
1182.00
PK15GTA
17.10
7R
225 A
4–250
42
42
0
HOM42M225RB
1323.00
PK23GTA
21.30
14R
Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs c
150 A
8
16
8
HOM816M150FTRB
785.00
4–250
PK15GTAL
35.00
6R
200 A e
8
16
8
HOM816M200FTRB
785.00
4–250
PK15GTAL
35.00
6R
Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker or Main Lugs c
QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See Kits Below)
200 A
8
16
8
HOM816U200FTRB
446.00
4–250
PK15GTAL
35.00
6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
a
Maximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
b
HOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
c
Side hinge door device allow 1-1/4 in. on left side for door to open.
d
22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
e
Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire.
f
70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
Field-Installed Kits
Table 1.45:
Main Lug Kit
QOL125
QOL225
1-16
Field-Installed Mains, Convertible Load Centers Only
Main g
Use on Convertible Load
$ Price
Lug Wire Size j
Cat. No.
Ampere Rating
Center with Mains Rating
(DE3A)
AWG/kcmil
125 A
100–125 A
QOL125
44.10
6–2/0 Al or Cu
Main Lug h
—
225 A
150–225 A
QOL225
104.00
6–300 Al or Cu
50 A
100–125 A
QOM50VH
140.00
60 A
100–125 A
QOM60VH
140.00
70 A
100–125 A
QOM70VH
140.00
80 A
100–125 A
QOM80VH
201.00
QOM1
12–2/0 Al or Cu
90 A
100–125 A
QOM90VH
201.00
100 A
100–125 A
QOM100VH
201.00
110 A
125 A
QOM110VH
468.00
Main Circuit
Breaker i
125 A
125 A
QOM125VH
468.00
100 A
150–225 A
QOM2100VH
468.00
125 A
150–225 A
QOM2125VH
468.00
150 A
150–225 A
QOM2150VH
468.00
QOM2k
4–300 Al or Cu
175 A
200–225 A
QOM2175VH
468.00
200 A
200–225 A
QOM2200VH
468.00
225 A
225 A
QOM2225VH
468.00
g
Do not exceed the load center mains rating.
h
If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13.
i
22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with
up to 22 kA available fault current.
j
Wire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see
pages 1-5 through 1-11 under Main Wire Size.
k
Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00.
Field-Installed
Main Type
Frame Size
DE3A
DE3C
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® and Homeline® Load Centers
Indoor Load Centers–Dimensions, Knockouts
Class 1130, 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
A
Indoor Knockout Information and Enclosure Dimensions
A,B,C,D
A,B,C
A,B,C
A
A,B,C
A
Table 1.46:
Enclosure Dimensions
A,B,C
A,B
A
B,C,D,E
B,C,D,E
C,D,E,F,G
A A,B
B,C,D,E
C,D,E,F
B,C,D,E
A,B
A
A
B,C,D,E
B,C,D,E
A,B,C,D
B,C,D,E
Box 4
in.
3.81
4.81
4.81
8.88
14.25
14.25
14.25
14.25
14.25
14.25
14.25
14.25
1
2
3
4
5
6
7
8
9
10
11
12
Box 3
Box 2
Box 1
B,C,D,E
A
A,B
Table 1.47:
C,D,E,F,G
C,D,E,F,G
mm
171
236
236
319
379
455
531
661
758
858
965
1000
in.
3.00
3.19
3.19
3.80
3.75
3.75
3.75
3.75
3.75
3.75
3.75
3.75
W
Box
No.
mm
76
81
81
97
95
95
95
95
95
95
95
95
in.
5.88
14.25
20.00
20.00
20.00
5.88
7.56
9.62
8.88
8.55
14.25
13
14
15
16
17
18
19
20
21
22
23
H
mm
149
362
508
508
508
149
192
244
226
217
362
in.
13.12
20.92
50.00
62.00
53.00
16.12
23.12
26.12
14.80
23.92
29.86
D
mm
333
531
1270
1727
1346
409
587
663
376
608
758
in.
3.38
3.75
5.75
5.75
5.75
3.38
4.25
4.75
3.80
3.95
3.75
mm
86
95
146
146
146
86
108
121
97
100
95
Knockout Information
Knockouts
A A,B
A
B
C
Conduit
Size
1/2
3/4
1
C,D,E,F,G
D
E
1-1/4 1-1/2
F
G
H
I
2
2-1/2
3
3-1/2
C,D,E,F,G
B,C,D,E
C,D,E,F
A A,B
D,E,F,G
C,D,E,F
B,C,D,E
C,D,E,F
A A,B
D
in.
6.72
9.30
9.30
12.57
14.92
17.92
20.92
26.04
29.86
33.78
37.98
39.37
Symbol
B,C,D,E
B,C,D,E
mm
97
122
122
226
362
362
362
362
362
362
362
362
Box 5
B,C,D,E
Dimensions
H
1
A
W
Box
No.
LOAD CENTERS
Dimensions
A
B,C,D,E
C,D,E,F
A A,B
B,C,D,E
D,E,F,G
B,C
C,D,E,F,G
D,E,F,G
A A,B
B,C,D,E
D,E,F,G
B,C
A,B
B,C,D,E
C,D,E,F
A,B
A,B
A
A,B
A
A
A
A,B,C,D
A,B,C,D
Box 6
B,C,D,E
C,D,E,F
C,D,E,F,G
D,E,F,G
B,C,D,E
Box 7
C,D,E,F,G
D,E,F,G
Box 10
A A,B
C,D,E,F
D,E,F,G
A,B
B,C
B,C
A,B,C,D
C,D,E,F
D,E,F,G
Box 9
Box 8
B,C,D,E
B,C,D,E
A A,B
B,C,D,E
D,E,F,G
A,B,C,D
C,D,E,F
D,E,F,G
A,B,C,D
D,E,F,G,H
D,E,F,G,H,I
C,D,E,F
A,B,C
A
A,B
D,E,F,G
A,B
B,C,D,E
A,B
C,D,E,F
C,D,E,F
A,B,C,D
A
A,B
A
A
A,B,C,D
C,D,E,F
D,E,F,G
A,B,C,D
B,C,D,E
A,B,C,D
B,C,D,E
C,D,E,F
Box 14
Box 13
Box 12
Box 11
Box 15, 16, 17
A,B,C
A
C,D,E,F
D,E,F,G
B,C
C,D,E,F E,F,G,H
C,D,E,F
A,B,C,D
D,E,F,G
A,B
D,E,F,G
D,E,F,G
A,B
B,C,D,E
D,E,F,G
A
B,C,D,E
A,B
B,C,D,E
B,C,D,E
A
A
A,B
B,C,D,E
B,C,D,E
C,D,E,F
Box 18
© 2009 Schneider Electric
All Rights Reserved
Box 19
Box 20
Box 21
A,B,C,D
C,D,E,F
D,E,F,G
B,C,D,E
Box 22
Box 23
1-17
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
QO® and Homeline® Load Centers
Rainproof—Dimensions, Knockouts, Bolt-on Hubs
Class 1130, 1170 / Refer to Catalog 1100CT0501
www.schneider-electric.us
2 1 2" Hub Maximum
1
2 1 2" Hub Maximum
Table 1.48:
Enclosure Dimensions
Dimensions
W
H
in.
mm
in.
1NM
6.52
166
8.79
1Ra
4.88
124
9.38
2R
8.88
226
12.65
3R
14.75
375
18.92
4R
14.75
375
22.06
5R
14.75
375
26.04
6R
14.75
375
29.86
7R
14.75
375
33.78
8R
14.75
375
37.98
9R
4.56
116
6.50
10R
6.92
176
13.18
11R
7.56
192
23.24
12R
9.62
244
26.24
13R
6.92
176
16.18
14R
14.75
375
39.37
15R
8.88
226
14.80
16R
8.55
217
24.75
17R
8.88
226
12.65
HOME250SPA and QO260NATR top endwall has no hub opening.
Box No.
B,C
B,C
A,B
A,B
LOAD CENTERS
Box
Box 1NM
1NM
A
A,B
A,B,C,D
B,C,D,E A
B,C,D,E
Box 1R
A,B
B,C,D,E
Box 2R
2 1 2" Hub Maximum
2 1 2" Hub Maximum
C,D,E,F,G
C,D,E,F,G
C,D,E,F
A,B,C
A A,B C,D,E,F,G
C,D,E,F
C,D,E,F
Box 3R, 4R
A,B,C
A A,B C,D,E,F,G
2 1 2" Hub Maximum
C,D,E,F
Box 5R
a
Table 1.49:
D
mm
223
238
321
481
560
661
758
858
965
165
335
590
666
411
1000
376
629
321
in.
3.90
4.00
4.27
4.52
4.52
4.52
4.52
4.52
4.52
3.88
4.12
4.75
5.50
4.12
4.52
4.27
4.16
4.27
mm
99
102
108
115
115
115
115
115
115
99
105
121
140
105
115
108
106
108
Knockout Information
Knockouts
C,D,E,F,G
A,B,C
Symbol
A
B
C
D
E
F
G
H
Conduit Size
1/2 in.
3/4 in.
1 in.
1-1/4 in.
1-1/2 in.
2 in.
2-1/2 in.
3 in.
Box 9R
C,D,E,F
A,B,C
A A,B C,D,E,F,G
C,D,E,F
2 1 2" Hub Maximum
2 1 2" Hub Maximum
2 1 2" Hub Maximum
Box 6R, 7R, 8R
2 1 2" Hub Maximum
2 1 2" Hub Maximum
B,C,D,E
B,C,D,E
A
D,E,F,G
Box 11R
C,D,E,F
Box 15R
B,C,D,E
C,D,E,F,G
2 2" Hub Maximum
1
A,B,C,D
A,B
B,C,D,E
2 2" Hub Maximum
1
B,C,D,E
B, C, D, E
B, C, D, E
A
Power lnlet
B, C, D, E
Box 10R, 13R
17R
A,B
C,D,E,F
D,E,F,G
E,F
E,F,G,H
A,B,C
A A,B C,D,E,F,G
C,D,E,F
C,D,E,F
Box 14R
Box 16R
Box 12R
Bolt-On Hubs
Square D equipment with “R’’ or “RB’’ suffix, designated NEMA 3R rainproof construction,
utilizes bolt-on hubs listed below. “RB’’ devices will accept 3/4 in. through 2-1/2 in. bolt-on
hubs without the use of reducers. Off-center conduit thread openings and elongated
mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and
bends. Catalog suffix “R’’ devices require 3 in. through 4 in. field cut opening. Hubs are
suitable for use with conduit having ANSI standard taper pipe thread.
Table 1.50:
Bolt-On Hubs UL Listed for “RB” Devicesb
Conduit Size
3/4 in.
1 in.
1-1/4 in.
1-1/2 in.
2 in.
2-1/2 in.
Hub Cat. No.
B075
B100
B125
B150
B200
B250
$ Price
b
33.30
33.30
61.35
102.00
Bolt-On Hubs UL Listed for Mounting in Field-Cut Opening
Conduit Size
3 in.
3-1/2 in.
4 in.
Hub Cat. No.
B300
B350
B400
$ Price
1-18
33.30
Closing cap (Cat. No. BCAP) is provided factory-installed on each device having “RB’’ suffix.
Price if ordered separately; $2.50
Table 1.51:
“RB’’ Hub
33.30
DE1A
186.00
Discount
Schedule
300.00
Designed for mounting in field cut opening.
Includes gasket and four mounting bolts and nuts.
368.00
© 2009 Schneider Electric