Energistx Mobile Medical 2010 PDF Catalogue

Energistx Mobile Medical 2010 PDF Catalogue
www.energistx.com
866-733-8686
Contact:
Halle Blessing
831.423.6363
Toll Free-24 hrs
[email protected]
Energistx
Mobile Medical Units
Dear Customer,
Thank you for contacting Energistx for your Mobile Medical solutions. We offer a
diverse selection of mobile platforms, floorplans, and equipment to meet your
unique specifications and field applications. Units described here are manufactured
in the US between a handful of experienced Manufacturers specializing in Mobile
Medical Units and Hospitals. You may choose from our existing floorplans or have
units custom designed to your specs. Units take 1 to 7 months to manufacture.
Energistx is not a middleman or reseller, but an actual Manufacturer’s Rep, so you
contract directly with the Manufacturer. If you have specific design or equipment
requirements, and are ready for a quote, please request a Design Questionnaire.
International Disaster Services: Builds container-based
units in 8x40 ft configurations primarily. Economical, extra-durable
construction in solid steel shipping containers. Custom designed or
choose from existing floorplans. Units can come fully equipped or
customer may install specialty medical equipment upon delivery.
Medcoach: Builds turn-key, fully mobile, semi- or van mounted
units complete with new medical equipment to your specifications
since 1949. Unsurpassed quality and experience, delivering reliable
medical facilities internationally for both private and governmental
organizations. Many floorplans to choose from. Financing Available.
ABMSC: Builds fully equipped, mobile modular
units, capable of being scaled out into a permanent
faciltiy. They are spacious semi-mounted buildings
completely stocked with medicines and equipment.
Custom designs and financing program available.
Expandable Hospital
Medical Units
American Bio-Medical Service Corporation (ABMSC) has developed the most advanced, fully selfsustaining, mobile medical care facility known to date. Currently, there are no other certified commercial
transportable medical units available with the self-sufficiency, mobility, and design flexibility.
As a fully functioning, self-sustaining mobile surgical/medical center, the mobile unit requires very little
setup time and comes equipped with security and monitoring systems. The spacious design flows from room
to room offering a comfortable environment for patients and staff. These modular units can be modified to
create ancillary facilities, such as housing or teaching units for staff and patients.
All models are mobile and capable of being transported by cargo ships, overland haulers, or military helicopters. Each mobile unit can remain on its own axle or can be installed on a foundation for semi-permanent
or permanent use. The units can also be linked to form a modular building complex, such as a full-fledged
hospital.
Features
• The mobile unit can be connected to local commercial utility power. (Back-up power will automatically
kick in if interrupted.)
• The generator is capable of continuous 24-hour operation for one week using diesel fuel.
• Self-contained fresh water supply; black and grey waste tanks all concealed under unit.
• Redundant air-conditioning system with five fan-coils and individually controlled temperature zones.
• On-demand electric water pump used for all sinks, water heater, and toilets; built-in 10-gallon water
heater.
• Fully installed medical gas and vacuum system (includes manifold, monitors and alarm system).
Complete security systems with outside remote camera system.
Custom Construction
• Exterior can be modified to customer color or design (i.e., national flag, etc.) specifications.
• Built specifically to handle the rigorous conditions found in disaster areas or environmentally hostile locations.
• Entire undercarriage can be insulated and sealed against severe climatic conditions.
1
50 Bed Expandable
Hospital Option 1
1
EN
EN--ABMC
ABMC--01
Page 1
50 Bed Expandable
Hospital Option 2
1
EN
EN--ABMC
ABMC--02
Page 2
Mobile Exam Room
1
“CORONET”
Emergency Rescue Hospital Unit
Print #3345
Approximate Interior Dimensions
Length ……... 19’ 6” (5.94M)
Width .……...
7’ 6” (2.29M)
Height ….......
6’10” (2.08M)
1.
BODY FRAMING AND ASSEMBLY:
A.
In accordance with good engineering practice, the vehicle frame shall be
lengthened or shortened to the required body length to provide support for all
body crossmembers.
B.
Hardwood bed pieces shall be fitted to the top surface of the chassis frame, and
counter bored to accommodate chassis frame rivets, to give uniform load
distribution over the vehicle frame. Hardwood fillers shall be treated with wood
preservative.
C.
The hardwood bed pieces shall be capped with hi-tensile steel, 3-inch channel
along the full length of the longitudinal frame members.
D.
Evenly spaced, threaded “U” bolts, with tie bars and captive nuts, shall secure the
body, steel channel and bed pieces to the chassis frame.
E.
Floor crossmembers shall be placed on approximately 16-inch centers and shall
be of adequate size to carry body and payload without fracture or failure;
minimum 11-gauge steel.
F.
Longitudinal members, if required, shall be constructed of steel and shall be free
of fractures to the full length of the section.
050201/1943
399 Co Hwy 58 P.O. Box 129 Oneonta, New York 13820 (607) 432-1333 FAX (607) 432-8190
The global leader in “Custom Mobile Systems” since the 1940s …
Visit us on the Web at www.medcoach.com
“CORONET”
Specification
1.
2.
BODY FRAMING AND ASSEMBLY: Continued …..
G.
General body wall construction shall consist of roll-formed “C” channels, 8.625
inch high by 1.75 inch deep, 3003-H14 aluminum alloy, .080 inch thick. The
channels shall run horizontally the entire length and width of the unit and shall be
secured to aluminum corner posts, roof rail and lower rail using 3/16-inch brazier
head aluminum rivets. Finished exterior body surfaces shall be smooth with no
rivets.
H.
The roll-formed “C” channels shall comprise the exterior body sides and end
panels. The channels shall be fastened together along their full length with
Plexus, or equal, high-performance adhesive specially designed for metal bonding
(same as widely used in transportation, marine, and aviation industries). The
bond formed has a tensile strength of approximately 2,500 PSI (strain-to-failure
ration greater than most commercial mechanical fasteners); temperature resistance
range of -67° F to +250° F; chemical resistance; high-fatigue endurance; and
impact resistance.
I.
Each wall section shall be reinforced with vertical aluminum members, which are
welded on a minimum of 48-inch centers.
J.
The roof carlines shall be aluminum extrusions, 6063-T6 alloy, which shall be
welded to the roof rail on 16-inch centers. The roof assembly shall consist of a
one-piece, .040-inch aluminum roof. Roof panel to be secured around perimeter
with adhesive and 3/16-inch brazier head aluminum rivets to aluminum extruded
roof rail.
K.
All window and door openings shall be framed with welded aluminum structures
and gusseted to prevent torsional twisting. Heavy-gauge metal tapping plates
shall be installed between frame members to secure heavy wall-mounted
equipment as per custom body floor plan. Around perimeter of interior body at
ceiling, an integral part of roof rail is provided to secure ceiling, side panels and
overhead cabinets. At ceiling, there shall be installed tapping plates to permit
positive securing of light fixtures.
L.
Unit shall be equipped with lights and directional signals (front and rear) and
back-up lights in accordance with D.O.T. Safety Regulations. Cab equipped with
mirror on left and right sides.
M.
Lower front corners of body shall be protected by 3M, Mylar, or equal, gravel
guards.
“CORONET”
Specification
2.
3.
INSULATION:
Body shall be insulated on sides, ends, floor and ceiling with foamed-in-place urethane.
Insulation offers optimum environmental protection; adds support to sides, ends and roof;
prevents entrance of moisture; and acts as a sound retardant. (Minimum: R-12.)
3.
4.
WALLS AND CEILING:
A.
The interior walls shall be lined for full width and length with 1/4-inch thick
laminated formica panels. Panels shall be secured with joiners, edgings and
moldings specifically designed for this purpose.
B.
Ceiling shall be surfaced with NUDO Products, FiberCorr, or equal, ceiling
panels, consisting of .090-inch FRP overlay laminated to a corrugated plastic
core.
FLOOR:
A.
Between cross sills, secure 26-gauge galvanized sheet to fully enclose floor area.
Above cross sills, secure 3/4-inch thick plywood which is laminated on both sides
with fiberglass-reinforced-plastic panels. The panel edges to be treated with
edge-sealer for water resistance. Underside of floor panels exposed to road shall
be sprayed with Quaker Koat, or equal, sound-deadening undercoating.
B.
Floor shall be surfaced with Armstrong, or equal, heavy-duty cushioned vinyl
linoleum.
“CORONET”
Specification
5.
6.
4.
PAINTING PROCEDURES:
A.
Body exterior shall be thoroughly cleaned, sanded and primed with PPG urethane
primer. Body shall be painted with two (2) coats of PPG polyurethane topcoat,
one color of buyer’s choice.
B.
Body shall be undercoated with Quaker Koat, or equal, sound-deadening
undercoating.
ENTRANCE/EXIT DOOR(S):
A.
Doors shall be pan-type, constructed of 0.125-inch aluminum with aluminum tube
reinforcement. Shall be insulated with structural urethane and close on dustsealing neoprene extrusions. Door(s) shall include safety-glass window with
designer venetian blinds plus double-acting door latch meeting FMVSS #206
standards with keyed lock. Hinges shall be stainless steel, continuous type with
3/16-inch (minimum) hinge pin. Suitable safety steps and grab handles shall be
installed at door locations.
B.
Install safety-tread, pullout steps at side entrance/exit locations. Includes a
handrail system for patient convenience.
“CORONET”
Specification
7.
5.
ELECTRICAL SYSTEM:
Unit shall be wired to receive 4-wire, 120/240-volt, 60-Hertz, AC, single-phase, 30-amp
power from generator or local power source via lead-in cable. Necessary wiring shall be
provided for operation of 120/240-volt equipment where indicated.
8.
9.
WIRING:
A.
All wiring shall be NEC standard conduit with stranded wire or plastic jacketed,
non-metallic sheathed cable with ground. Wiring and related devices shall be
installed in a workmanlike manner, mechanically and electrically secure. Items
requiring periodic service shall be readily accessible and serviceable. Wiring
shall be protected by grommets when passing through structural members.
B.
Circuit breakers panel(s) of adequate capacity shall be installed at appropriate
locations within body and shall include:
1.
Individual 120-volt circuits for utility equipment, lights, air conditioning
and receptacles.
2.
240-volt for electric heating units.
C.
Duplex receptacles shall be provided in convenient locations within body interior
to conform to National Electric Code.
D.
Provide 50-foot, 4-wire lead-in cable with waterproof receptacle on one end and
alligator clips on other end for connection to 120/240-volt power source. Cable
shall be sized to unit capacity.
LIGHTING:
A.
Fluorescent lights in standard 1-, 2-, or 4-tube fixtures shall be surface-mounted
on interior body ceiling within plastic diffuser panels or beneath cabinets above
work surfaces. Diffusers shall be equipped with latching device to prevent falling
in transit.
B.
12-volt dome lights shall be provided at each door entrance and within exterior
body compartments.
C.
Install a floodlight on unit exterior at each door entrance. Floodlight shall be
controlled by interior switch.
“CORONET”
Specification
10.
11.
6.
GENERATOR/GENERATOR COMPARTMENT: (Gasoline Generator)
A.
Compartment shall be accessible from side via hinged, louvered doors equipped
with flush-mounted locks and holders in the open position
B.
Compartment shall be properly framed with aluminum members and surfaced
with .090-inch aluminum panels. Compartment shall be enclosed with 1/2-inch
Homosote on the body interior and surfaced with formica counter topping and
paneling on the vertical wall. Area between the inner and outer walls of
compartment shall be insulated with foamed-in-place urethane.
C.
Provide a 7.5 kilowatt Onan, or equal, 120/240-volt, 60 Hertz, single phase,
generator equipped with vacuum cooling device, remote controls, starting battery,
and critical area silencer. Shall be installed for easy servicing, proper heat and
exhaust dissipation, and connected to vehicle fuel tank for gasoline supply.
D.
Generator shall be hard-wired to a three-position, manual transfer switch to
change power input from generator to local power source, if available.
E.
Generator shall be shock-mounted on vibration isolators.
F.
A seamless exhaust section shall connect the generator manifold with the intake
of the critical area silencer. A 5-foot flexible, stainless steel exhaust extension
equipped with quick-disconnect connector shall be provided to add to underbody
exhaust line for additional exhaust dissipation.
G.
A remote start/stop button, hour meter, and battery condition indicator shall be
installed within body interior
H.
Compartment shall be lined with Tufcote, or equal, sound barrier material
AIR CONDITIONING/HEATING:
A.
Install two (2) Coleman, or equal, roof-mounted air conditioners with electric
resistance heat strip within reinforced roof section. Units shall be rated at 13,500
BTU cooling and 5,600 BTU heating; 120 volt.
B.
Install two (2) thermostatically controlled, electric blower heaters within the body
interior. Each heater rated at a minimum of 3,400 BTU.
“CORONET”
Specification
12.
7.
PLUMBING:
A.
The plumbing system shall be designed to receive water directly from local
sources or from the installed tank. Plumbing fixtures, devices and appurtenances
shall be supplied with water in sufficient volume and at pressures adequate to
enable them to function satisfactorily and without undue noise. All water piping
shall be subjected to adequate water and pressure tests to determine leakage or
loss in pressure.
B.
The plumbing system shall include:
1.
2.
3.
4.
One (1) 20-gallon fresh water tank,
One (1) 25-gallon wastewater tank with hose connection,
One (1) Flojet, or equal, 120-volt heavy-duty water pump,
One (1) 6-gallon electric water heater.
C.
The fresh water tank shall be installed within an insulated underbody skirt
compartment accessible through a hinged door with flush-mounted lock and
holding device for door in open position. Compartment shall be provided with
electric heater for winter protection against freezing.
D.
Fresh water tank shall be connected to water heater and water faucet at sink by
high pressure, polybutylene tubing.
E.
Plumbing system shall be equipped with check valves in accordance with
approved commercial practice.
F.
Provide one (1) 50-foot water hose and one (1) wastewater hose. Hoses to be
different sizes to prevent intermix.
G.
Install a dispenser for folding paper towels at each sink location.
H.
Waste water shall drain to waste tank or hose connection through corrosionresistant PVC tubing.
I.
Unit shall be equipped with a water filter with replaceable filter element.
“CORONET”
Specification
14.
8.
INTERIOR FURNISHINGS:
A.
B.
Patient Area:
1.
On each side of body interior, provide heavy-duty squad bench with
storage under. Includes reinforcement, hinged doors, “U”-guide channels
to receive litter feet, and a removable upholstered seat pad. Stretcher
hold-downs also provided.
2.
Provide four (4) military litter-type, Ferno Model FW-108AF, pole
stretchers. Includes vinyl-covered canvas and rugged aluminum cross
spreaders and feet. Stretchers can be folding for storage.
3.
Two (2) stretchers shall be suspended from the ceiling above squad
benches. Includes ceiling suspension, plastic-coated eye bolts, and
aluminum suspension bars with plastic-coated lower hook, plus plasticcoated wall hooks with special “captive” top design to prevent stretchers
from bouncing out in transit. All hardware fastened to heavy-duty tapping
plates.
Surgical Room:
1.
Accessible through double-swinging doors equipped with locking device
on both sides. Doors shall be equipped with an aluminum kick-scuff plate
on both sides at bottom. Aluminum, stainless steel, or chrome hand push
plates shall be provided in the upper section of each door on both sides.
2.
Install a UMF 5835, or equal, examining and operating chair/table
equipped with articulated backrest, shoulder rests, stirrups, cushion, and
Trendelenburg feature.
3.
Build in a stainless steel sink within formica surfaced work counter. Shall
include hot and cold water mixing faucet energized by foot pedals.
4.
Install on shelf above sink cabinets a Vernitron 8020, or equal, autoclave
with capacity for three instrument trays.
5.
Provide and secure a UMF, or equal, double bowl stainless steel solution
stand. Stand mounted on a 2-inch conductive soft rubber, easy swivel,
ball bearing casters.
6.
Provide and secure a UMF, or equal, kick bucket with a 12-quart stainless
steel pail encircled with a conductive rubber bumper. Mounted on ballbearing conductive rubber casters.
“CORONET”
Specification
14.
9.
INTERIOR FURNISHINGS: Continued …..
B.
Surgical Room: Continued …..
7.
Provide and secure a Wilson Magee stainless steel crash cart. Includes
three (3) full width drawers, with nylon rollers; and full-width storage
compartment at bottom. Unit is mounted on 5-inch ball bearing casters.
Tubular steel push handle with donut-type rubber bumpers. Lower
corners have heavy-duty corner bumpers. Includes stainless steel Mayo
attachment, double hook irrigator rod, adhesive rack, cardiac pressboard,
and conductive casters.
8.
Install UMF Model SS8201, or equal, treatment cabinet with stainless
steel top and bottle rack.
9.
Provide and secure a stainless steel Mayo stand, UMP Model SS8310, or
equal.
10.
Provide a floor- or wall-mounted, high intensity surgical lamp, Burton
Model 11201, or equal.
11.
Provide an oxygen administration unit complete with one (1) oxygen
cylinder (“E” size), regulator, flowmeter, humidifier, 10-foot tubing, and
masks mounted on crash cart.
“CORONET”
Specification
14.
10.
MISCELLANEOUS:
A.
Four (4) removable, heavy-duty, swing-away stabilizing jacks shall be provided.
B.
Two (2) 2-1/2 pound dry chemical fire extinguishers shall be bracketed and
installed within body interior.
C.
One (1) highway warning kit, including three (3) red emergency triangle
reflectors shall be provided.
D.
Underbody storage compartments shall be provided to store lead-in cable, etc.
Accessible through hinged doors with holding devices and flush-mount chrome
locks.
E.
Install coat hooks at convenient locations within body interior.
F.
Provision shall be made for securing all equipment during operational transit.
G.
Two (2) copies of Medical Coaches’ Operator’s Manual shall be provided. Shall
include one (1) set of supporting manuals covering supplied items such as chassis,
generator, air conditioner, etc., if supplied.
H.
Install an access port within the compartment or compartment door of every
generator, electrical cable and plumbing compartment allowing the lead-in cable
and hoses to be connected to the unit with the main compartment doors closed and
locked.
I.
An emergency 12-volt lighting system with rechargeable battery and trickle
charger shall be installed.
“CORONET”
Specification
15.
16.
11.
CHASSIS/BODY EQUIPMENT:
A.
All vehicle lights (chassis and body), reflectors, markings and wiring systems
shall be in conformance with D.O.T. safety regulations and state laws. The
system shall be 12-volt. Lights shall not be mounted on rub rails or vehicle
bumper. An illuminated rear license plate holder shall be furnished.
B.
Turn signals, SAE Class A, Type I, with Class A operating units mounted on the
steering column shall be furnished. Vehicle shall be equipped with single-faced
front and rear signal units installed in accordance with SAE recommendations.
Operating units shall be provided with a visible and an audible flash indicator.
Back-up lights shall be installed.
PRE-DELIVERY PREPARATION:
Prior to delivery the entire vehicle shall be serviced by a local authorized chassis dealer
for drive-away delivery. Each component will be serviced in accordance with the
manufacturer’s recommendation.
17.
18.
SPECIAL REQUIREMENTS:
A.
Details concerning colors, exterior painting, and lettering, etc., plus delivery of
completed unit to be arranged at a later date in accordance with buyer’s wishes.
B.
Due to variances in state and local regulations, there may be some additional
options required for individual compliance. If compliance necessitates extra-cost
options, they will be quoted separately as necessary.
LIMITED WARRANTY:
A.
Medical Coaches Incorporated offers a limited warranty on the mobile unit for
twelve (12) months or 12,000 miles. The warranty includes all equipment
supplied by Medical Coaches except those items that are covered by a separate
warranty.
B.
A detailed warranty statement shall be provided upon purchase or upon request.
“CORONET”
Specification
12.
OPTIONAL ITEMS :
CHECK IF
DESIRED:
A.
Lettering exterior body at sides, front and rear to buyer’s order (Special artwork
and emblems at extra cost.) ....................................................................................
B.
Paint body two-tone instead of standard one color ................................................
C.
Paint truck cab other than standard color ...............................................................
D.
Unit to be wired for 50-Hertz service (Export Only):
1. Generator to be de-rated to produce 220-volt, 50-Hertz, AC, 2-wire power.
Includes grounding rod with chain. All electrical equipment within body to
be equipped for 50-Hertz service ......................................................................
2. If any 110-volt equipment is to be installed, provide a 3,000-watt step-down
transformer and connections to 110-volt receptacles .......................................
E.
Provide a stereo AM/FM radio/compact disc player connected to overhead
speaker system. Includes body-mounted antenna ..................................................
F.
35-item tool kit contained in metal carrying case ...................................................
G.
24-unit first aid kit with all necessary bandages, antiseptics and burn ointments
contained in a steel box ..........................................................................................
H.
Provide one (1) folding aluminum table and two (2) steel folding chairs ..............
I.
Exterior Tent: To be a Eureka, Riverside, or equal, 9-feet x 12-feet with center
height of 7-feet 6-inches, full floor, door and three (3) large windows with storm
flaps. To be used for additional patient area or staff living area ...........................
J.
Fisher Micromaster I, or equal, binocular microscope with carrying case .............
K.
Two burner electric hot plate ..................................................................................
L.
Trauma Kit II, trauma/first aid kit, approximately 100 items. (List available upon
request.) ..................................................................................................................
M.
Generator spare parts kit .........................................................................................
N.
IV stand, stainless steel base, telescoping action, double hook cross piece, locking
device, and three (3) 2-inch conductive casters. ..................................................... O.
Anesthesia System – OHMEDA, Excell 110, or equal, 2 gas anesthesia machine
with ventilator, GMS absorber, Halothane vaporizer, and gas scavenger ..............
P.
GOMCO, or equal, surgical suction unit ................................................................
Q.
Two (2) five gallon emergency gasoline cans bracketed and secured against theft.
“CORONET”
Specification
13.
CHASSIS SPECIFICATION
Chassis Model ..........................................
Wheelbase ................................................
Cab-to-Axle ..............................................
Gross Vehicle Weight Rating (GVWR) ...
Engine (Gasoline) .....................................
Transmission (Manual) .............................
Clutch .......................................................
Brakes (Service) .......................................
Steering .....................................................
Alternator ..................................................
Battery ......................................................
Axle, Front ................................................
Axle, Rear .................................................
Springs, Front ...........................................
Springs, Rear ............................................
Tires (6) ....................................................
Shock Absorbers........................................
Gauges ......................................................
Radiator ....................................................
Seat ...........................................................
Glass ..........................................................
Heater and Defroster ................................
Mirrors ......................................................
Bumper and Grille ....................................
Seat Belts ..................................................
Windshield Wipers ...................................
Armrests ...................................................
Sun Visors ................................................
Horn ..........................................................
Fuel Tanks ................................................
Frame ........................................................
Color .........................................................
Chevrolet/GMC C7500 Chassis Cab
224 inches
156 inches
26,000 pounds
V-8 (8.1L) 295 HP
5-speed
Heavy-duty
Power, split-hydraulic
Power
105 amp
Delco Freedom II, F-20, 600 CCA
8,100 pounds
19,000 pounds
9,000 pounds
21,000 pound capacity with auxiliary
235/80R22.5G; singles front; duals rear
Front and rear
Voltmeter, oil pressure, water temperature
Increased cooling
Full width bench
Tinted
Fresh air
Dual, West Coast; stainless
Painted
Driver and passenger
2-speed electric with washers
Driver and passenger
Driver and passenger
Single electric
Dual, 50 gallon, step tanks
Reinforced
White
Optional Items:
A. Spare tire, wheel, and carrier ...............................
B. Cab air conditioning ............................................
C. AM/FM Radio .....................................................
D. 5-speed automatic transmission ...........................
E. 7.2L. diesel engine ...............................................
F. Full air brakes .......................................................
G. 4-wheel drive (4x4); custom conversion .............
050201/1943-GM
Check if
Desired:
“CORONET”
Specification
14.
CHASSIS SPECIFICATION
Chassis Model ..........................................
Wheelbase ................................................
Cab-to-Axle ..............................................
Gross Vehicle Weight Rating (GVWR) ...
Engine (Diesel) .........................................
Transmission (Manual) .............................
Clutch .......................................................
Brakes (Service) .......................................
Steering .....................................................
Alternator ..................................................
Batteries (Dual) ........................................
Axle, Front ................................................
Axle, Rear .................................................
Springs, Front ...........................................
Springs, Rear ............................................
Tires (6) ....................................................
Shock Absorbers........................................
Gauges ......................................................
Radiator ....................................................
Seats ..........................................................
Glass ..........................................................
Heater and Defroster ................................
Mirrors ......................................................
Bumper and Grille ....................................
Seat Belts ..................................................
Windshield Wipers ...................................
Armrests ...................................................
Sun Visors ................................................
Horn ..........................................................
Fuel Tanks ................................................
Frame ........................................................
Color .........................................................
Radio ........................................................
Ford F-650 Chassis Cab
230 inches
156 inches
26,000 pounds
Cummins 205 HP
6-speed
Heavy-duty
Power, split-hydraulic
Power
115 amp
93 amp-hr.; maintenance free, 625 CCA
9,000 pounds
17,500 pounds
8,500 pound capacity
17,500 pound capacity with auxiliary
10R22.5(F); singles front; duals rear
Front and rear
Ammeter, oil pressure, water temperature
Increased cooling
Driver with 2-passenger
Tinted
Fresh air
Dual, West Coast; stainless
Painted
Driver and passengers
2-speed electric with washers
Driver and passenger
Driver and passenger
Dual electric
Dual, 50 gallon, step tanks
Reinforced
White
AM/FM
Optional Items:
A. Spare tire, wheel, and carrier ...............................
B. Cab air conditioning ............................................
C. AM/FM Radio with CD player ...........................
D. 4-speed automatic transmission (AT 545) ..........
E. Full air brakes ......................................................
F. 4-wheel drive (4x4); custom conversion ..............
050201/1943-F
Check if
Desired:
“CORONET”
Specification
15.
CHASSIS SPECIFICATION
Chassis Model ..........................................
Wheelbase ................................................
Cab-to-Axle ..............................................
Gross Vehicle Weight Rating (GVWR) ...
Engine (Diesel) .........................................
Transmission (Manual) .............................
Clutch .......................................................
Brakes (Service) .......................................
Steering .....................................................
Alternator ..................................................
Batteries (2) ..............................................
Axle, Front ................................................
Axle, Rear .................................................
Springs, Front ...........................................
Springs, Rear ............................................
Tires (6) ....................................................
Shock Absorbers........................................
Gauges ......................................................
Seat ...........................................................
Glass ..........................................................
Mirrors ......................................................
Seat Belts ..................................................
Windshield Wipers ...................................
Armrests ...................................................
Sun Visors ................................................
Horn ..........................................................
Fuel Tanks ................................................
Frame ........................................................
Color .........................................................
Cab Air Conditioning ...............................
International; 4300 Chassis Cab (4x2)
218 inches
150 inches
25,500 pounds
International 7.3L; 195 HP @ 2600 RPM
6-speed
Heavy-duty
Hydraulic, split-system
Power
100 amp
12-volt, Maintenance Free, 1100 CCA total
8,000 pounds
17,500 pounds
8,000 pounds
18,500 pound capacity with 4,500 pound auxiliary
10R22.5(12PR); singles front; duals rear
Front and rear
English cluster with electronic speedometer and
tachometer
Full width bench
Tinted
Dual, West Coast; aluminum
Driver and passenger
2-speed electric with washers
Driver and passenger
Driver and passenger
Dual electric
Dual, 50 gallon, step tanks
Reinforced
White
Installed
Optional Items:
A. Spare tire, rim and carrier ....................................
B. AM/FM radio with CD ........................................
C. 4-speed automatic transmission (AT545) ...........
D. Air-ride suspension ..............................................
050201/1943-I
$650.
$450.
$3,555.
$2,535.
Check if
Desired:
“CORONET”
Specification
16.
CHASSIS SPECIFICATION
Chassis Model ..........................................
Wheelbase ................................................
Cab-to-Axle ..............................................
Gross Vehicle Weight Rating (GVWR) ...
Engine (Diesel) .........................................
Transmission (Manual) .............................
Clutch .......................................................
Brakes (Service) .......................................
Steering .....................................................
Alternator ..................................................
Batteries (2) ..............................................
Axle, Front ................................................
Axle, Rear .................................................
Springs, Front ...........................................
Springs, Rear ............................................
Tires (6) ....................................................
Shock Absorbers........................................
Gauges ......................................................
Seat ...........................................................
Glass ..........................................................
Mirrors ......................................................
Seat Belts ..................................................
Windshield Wipers ...................................
Armrests ...................................................
Sun Visors ................................................
Horn ..........................................................
Fuel Tanks ................................................
Frame ........................................................
Color .........................................................
International; 7300 Chassis Cab (4x4)
218 inches
150 inches
25,500 pounds
International DT466; 195 HP @ 2300 RPM
6-speed
Heavy-duty
Dual air system
Power
100 amp
12-volt, Maintenance Free, 1100 CCA total
10,000 pounds
17,000 pounds
10,000 pounds
18,500 pound capacity with 4,500 pound auxiliary
11R22.5(14PR); singles front; duals rear
Front and rear
English cluster with metric electronic speedometer
and tachometer
Full width bench
Tinted
Dual, West Coast; painted steel
Driver and passenger
2-speed electric with washers
Driver and passenger
Driver and passenger
Dual electric
Dual, 50 gallon, step tanks
Reinforced
White
Optional Items:
A. Spare tire, rim and carrier ....................................
B. Cab air conditioning ............................................
C. AM/FM radio with CD ........................................
D. 4-speed automatic transmission ...........................
050201/1943-I (4x4)
$750.
$1,570.
$450.
$8,640.
Check if
Desired:
“CASPIAN”
First Aid / Surgery / Recovery Trailer
Print #2502
Approximate Interior Dimensions
Length ……...
27’ 6” (8.38M)
Width ……....
7’ 6” (2.29M)
Height ……...
7’ 0” (2.13M)
1.
TRAILER AND BODY CONSTRUCTION:
A.
All steel heavy-duty trailer chassis shall consist of two longitudinal frame
members with structural shape cross members, outriggers and gusseting; customdesigned and equipped to support the trailer unit and interior load. Critical areas
shall be strengthened by the use of additional cross members and gusseting where
deemed necessary. An electrically welded perimeter shall be provided around
frame. All steel material shall conform to ASTM specifications.
B.
Running gear shall consist of a heavy-duty 24,000-pound tandem, bogie axle
assembly with sealed electric brakes on all axles. Each axle installed shall be
rated at 6,000 pounds capacity and equipped with matched tires, wheels and
springs. Axle assemblies shall be mounted to a steel under-carriage specially
designed to resist torsional twisting and to maintain proper weight distribution.
C.
Trailer to be equipped with electric brakes with connections to towing vehicle.
Includes drawbar coupler and hoist, meeting SAE-ICC requirements, safety
chains, safety breakaway and landing gear. Reinforced frame drawbar for heavyduty service.
D.
Trailer shall be equipped with running lights, reflectors, markers and wiring in
accordance with D.O.T. safety regulations. The system shall be 12-volt with
plug-in connection to towing vehicle. Running lights shall be installed within
chromed brush guards.
080301/0766
399 Co Hwy 58 P.O. Box 129 Oneonta, New York 13820 (607) 432-1333 FAX (607) 432-8190
The global leader in “Custom Mobile Systems” since the 1940s …
Visit us on the Web at www.medcoach.com
“CASPIAN”
Specification
1.
2.
TRAILER AND BODY CONSTRUCTION: Continued …..
E.
The trailer shall be equipped with a full width, steel rear bumper. The bumper
shall have reflective stripes to give an indication of the width of the trailer.
F.
General body wall construction shall consist of roll-formed “C” channels, 8.625
inch high by 1.75 inch deep, 3003-H14 aluminum alloy, .080 inch thick. The
channels shall run horizontally the entire length and width of the unit and shall be
secured to aluminum corner posts, roof rail and lower rail using 3/16-inch brazier
head aluminum rivets. Finished exterior body surfaces shall be smooth with no
rivets.
G.
The roll-formed “C” channels shall comprise the exterior body sides and end
panels. The channels shall be fastened together along their full length with
Plexus, or equal, high-performance adhesive specially designed for metal bonding
(same as widely used in transportation, marine, and aviation industries). The
bond formed has a tensile strength of approximately 2,500 PSI (strain-to-failure
ration greater than most commercial mechanical fasteners); temperature resistance
range of -67° F to +250° F; chemical resistance; high-fatigue endurance; and
impact resistance.
H.
Each wall section shall be reinforced with vertical aluminum members, which are
welded on a minimum of 48-inch centers.
I.
The roof carlines shall be aluminum extrusions, 6063-T6 alloy, which shall be
welded to the roof rail on 16-inch centers. The roof assembly shall consist of a
one-piece, .040-inch aluminum roof. Roof panel to be secured around perimeter
with adhesive and 3/16-inch brazier head aluminum rivets to aluminum extruded
roof rail.
J.
All window and door openings shall be framed with welded aluminum structures
and gusseted to prevent torsional twisting. Heavy-gauge metal tapping plates
shall be installed between frame members to secure heavy wall-mounted
equipment as per custom body floor plan. Around perimeter of interior body at
ceiling, an integral part of roof rail is provided to secure ceiling, side panels and
overhead cabinets. At ceiling, there shall be installed tapping plates to permit
positive securing of light fixtures.
K.
Floor crossmembers shall be 4-inch deep trailer “I” beams spaced on 16-inch
centers.
“CASPIAN”
Specification
2.
3.
INSULATION:
Body shall be insulated on sides, ends, floor and ceiling with foamed-in-place urethane.
Insulation offers optimum environmental protection; adds support to sides, ends and
roof; prevents entrance of moisture; and acts as a sound retardant. (Minimum: R-12.)
3.
4.
WALLS AND CEILING:
A.
The interior walls shall be lined for full width and length with 1/4-inch thick
laminated formica panels. Panels shall be secured with joiners, edgings and
moldings specifically designed for this purpose.
B.
Ceiling shall be surfaced with NUDO Products, FiberCorr, or equal, ceiling
panels, consisting of .090-inch FRP overlay laminated to a corrugated plastic
core.
FLOOR:
A.
Between cross sills, secure 26-gauge galvanized sheet to fully enclose floor area.
Above cross sills, secure 3/4-inch thick plywood which is laminated on both sides
with fiberglass-reinforced-plastic panels. The panel edges to be treated with
edge-sealer for water resistance. Underside of floor panels exposed to road shall
be sprayed with Quaker Koat, or equal, sound-deadening undercoating.
B.
Floor shall be surfaced with anti-static tile in Surgery Room and heavy-duty
linoleum in remainder of trailer.
“CASPIAN”
Specification
5.
6.
7.
4.
PAINTING PROCEDURES:
A.
Body exterior shall be thoroughly cleaned, sanded and primed with PPG urethane
primer. Body shall be painted with two (2) coats of PPG polyurethane topcoat,
one color of buyer’s choice.
B.
Steel structural trailer chassis undercarriage shall be painted black.
C.
Body shall be undercoated with Quaker Koat, or equal, sound deadening
undercoating.
ENTRANCE/EXIT DOOR(S):
A.
Shall be pan-type, constructed of 0.125-inch aluminum with aluminum tube
reinforcement. Shall be insulated with urethane and close on dust-sealing
neoprene extrusions. Door(s) shall include safety-glass window with designer
venetian blinds plus double-acting door latch meeting FMVSS #206 standards
with keyed lock. Hinges shall be stainless steel, continuous type with 3/16-inch
(minimum) hinge pin. Suitable safety steps and chromed grab handles shall be
installed at door locations.
B.
Provide lightweight aluminum hang-on steps at side entrance/exit locations.
Steps shall be equipped with adjustable neoprene feet and removable safety
handrails for patient convenience.
WINDOWS:
Install Hehr, or equal, sliding safety-glass windows with insect screens within body sides.
All windows shall be equipped with designer venetian blinds of appropriate color to
complement interior décor.
“CASPIAN”
Specification
8.
5.
ELECTRICAL SYSTEM:
Unit shall be wired to receive 4-wire, 120/240-volt, 60-Hertz, AC, single-phase, 60-amp
power from generator or local power source via lead-in cable. Necessary wiring shall be
provided for operation of 120/240-volt equipment where indicated.
9.
WIRING:
A.
All trailer wiring shall be NEC standard conduit with stranded wire or plastic
jacketed, non-metallic sheathed cable with ground. Wiring and related devices
shall be installed in a workmanlike manner, mechanically and electrically secure.
Items requiring periodic service shall be readily accessible and serviceable.
Wiring shall be protected by grommets when passing through structural members.
B.
Circuit breakers panel(s) of adequate capacity shall be installed at appropriate
locations within body and shall include:
C.
D.
10.
1.
Individual 120-volt circuits for utility equipment, lights and receptacles.
2.
240-volt for air conditioning and electric heating units.
Duplex receptacles shall be provided in convenient locations within body interior
to conform to National Electric Code.
Provide 50-foot, 4-wire lead-in cable with waterproof receptacle on one end and
alligator clips on other end for connection to 120/240-volt power source. Cable
shall be sized to unit capacity.
LIGHTING:
A.
Fluorescent lights in standard 1-, 2-, or 4-tube fixtures shall be surface-mounted
on interior body ceiling within plastic diffuser panels or beneath cabinets above
work surfaces. Diffusers shall be equipped with latching device to prevent falling
in transit.
B.
12-volt dome lights shall be provided at each door entrance and within exterior
body compartments.
C.
Install a floodlight on unit exterior at each door entrance. Floodlight shall be
controlled by interior switch.
“CASPIAN”
Specification
11.
12.
6.
GENERATOR: (Gasoline)
A.
Install a 15 kilowatt Kohler, or equal, 120/240-volt, 60 Hertz, single phase,
generator equipped with cooling device, remote controls, starting battery, and
critical area silencer. Generator shall be installed for easy servicing, proper heat
and exhaust dissipation, and connected to gas tank for fuel supply. Generator
shall be equipped with one (1) 5-foot pigtail cable section with 60-amp
waterproof receptacle for plugging into power inlet receptacle installed in front of
unit. Generator shall be shock-mounted and housed in weatherproof cover.
B.
Generator shall be mounted on tread-plate steel platform on front of trailer tow
bar. Entire generator shall be capable of being jacked off tow bar through use of
four (4) manual jacks. This will eliminate transmission of vibration into surgical
room.
C.
Install 50-gallon fuel tank under trailer skirt for fuel supply.
AIR CONDITIONING/HEATING:
A.
There shall be installed at the front of the mobile unit a Carrier, or equal, 230/208volt, 60 Hertz, single phase air conditioning unit. Unit shall be shock-mounted,
properly framed and connected to a metal duct installed between the roof and the
ceiling. Duct shall be insulated and shall include adjustable air diffusers
throughout body interior. Unit shall be thermostatically controlled. Condensate
shall be dispensed via flexible tubing from air conditioner to ground. A rust-proof
metal dust shield shall be provided in front of air conditioner intake, where
applicable.
Cooling capacity: 27,200 BTU.
B.
Install a total of two (2) thermostatically controlled, electric blower heaters
throughout body interior. Each heater rated at a minimum of 3,400 BTU.
“CASPIAN”
Specification
13.
7.
PLUMBING:
A.
The plumbing system shall be designed to receive water directly from local
sources or from the installed tank. Plumbing fixtures, devices and appurtenances
shall be supplied with water in sufficient volume and at pressures adequate to
enable them to function satisfactorily and without undue noise. All water piping
shall be subjected to adequate water and pressure tests to determine leakage or
loss in pressure.
B.
The plumbing system shall include:
1.
One (1) 40-gallon fresh water tank,
2.
One (1) 45-gallon wastewater tank with hose connection,
3.
One (1) Flojet, or equal, 120-volt heavy-duty water pump,
4.
One (1) 6-gallon electric water heater.
C.
The fresh water tank shall be installed within body interior for winter protection
against freezing.
D.
Fresh water tank shall be connected to water heater and water faucet at sink by
high pressure, polybutylene tubing.
E.
Plumbing system shall be equipped with check valves in accordance with
approved commercial practice.
F.
Provide one (1) 50-foot water hose and one (1) wastewater hose. Hoses to be
different sizes to prevent intermix.
G.
Install a dispenser for folding paper towels at each sink location.
H.
Waste water shall drain to waste tank or hose connection through corrosionresistant PVC tubing.
I.
Unit shall be equipped with a water filter with replaceable filter element.
“CASPIAN”
Specification
14.
8.
INTERIOR FURNISHINGS:
A.
Surgery Room:
1.
Accessible through swinging doors equipped with locking device on both
sides. Aluminum, stainless steel, or chrome hand push plates shall be
provided in the upper section of each swing door on both sides.
2.
Install a UMF 5835, or equal, surgical/exam chair/table equipped with
articulated headrest, drainage drawer, Bierhoff knee crutches, and cushion.
3.
Build in stainless steel sink within formica surfaced work counter. Shall
include hot and cold water mixing faucet energized by foot pedals.
4.
Provide and secure a double-bowl stainless steel solution stand. Mounted
on ball bearing conductive rubber casters.
5.
Provide and secure a kick bucket with a 12-quart stainless steel pail
encircled with a conductive rubber bumper. Mounted on ball bearing
conductive rubber casters.
6.
Provide and secure a Wilson, or equal, stainless steel crash cart. Includes
three (3) full-width drawers, nylon rollers, full-width storage compartment at bottom and tubular steel push handle with donut-type rubber
bumper. Includes stainless steel Mayo attachment, double-hook irrigator
rod, adhesive rack, cardiac cardiac pressboard, oxygen tank holder,
oxygen tank, regulator, humidifier, and masks.
7.
Install a UMF, or equal, treatment cabinet with bottle rack installed.
8.
Provide and secure a stainless steel Mayo stand.
9.
Provide a floor- or wall-mounted, high-intensity surgical lamp.
10.
Install on shelf above sink cabinets a Vernitron 8020 autoclave with
capacity for three (3) instrument trays.
11.
Provide and secure a portable anesthesia system, which includes: a 2-gas
anesthesia machine with ventilator, GMS absorber, Halothane vaporizer,
and gas scavenger. Ventilator includes oxygen, volume, and pressure
monitor. Two (2) each “D” size oxygen and nitrous oxide cylinders shall
be provided. (For use with non-flammable gases only. The surgical room
is not explosion proof.)
12.
Provide and secure a GOMCO, or equal, surgical aspirator (suction) with
catheters, collection bottle, and stand.
“CASPIAN”
Specification
14.
9.
INTERIOR FURNISHINGS: Continued …..
B.
C.
D.
Toilet Area:
1.
Shall be enclosed by floor-to-ceiling partition with access through hinged
door with louver in lower section.
2.
Install Thetford, Aqua-Magic, or equal, flush toilet with holding tank.
3.
Install a stainless steel sink with hot and cold water faucet.
4.
Provide toilet room accessories: to include: mirror, coat hooks, toilet paper
holder, and paper towel holder.
5.
Install a 120-volt power exhaust vent through exterior wall.
Dispensary/Laboratory Area:
1.
Build in laboratory counter with storage above. Under counter install
Jewett CT-1 blood bank refrigerator (less counter top). Unit equipped
with TMS monitor system as well as dual automatic controls.
2.
At desk provide castered, upholstered laboratory stool.
3.
Provide and secure a first aid treatment chair for ENT, arm, and leg
treatment. Includes side arms, basin, and cradle-type headrest.
4.
At streetside build in floor-to-ceiling storage closet with adjustable shelves
and pull-out drawers in lower section.
Recovery Area:
1.
Install two (2) recovery beds with foam rubber upholstered pads.
2.
Build in storage under pads.
“CASPIAN”
Specification
15.
10.
MISCELLANEOUS:
A.
Four (4) removable, heavy-duty, swing-away stabilizing jacks shall be provided.
B.
Two (2) 2-½ pound dry chemical fire extinguishers shall be bracketed and
installed within body interior.
C.
Underbody storage compartments shall be provided to store lead-in cable, etc.
Accessible through hinged doors with holding devices and flush-mount chrome
locks.
D.
Install coat hooks at convenient locations within body interior.
E.
Provision shall be made for securing all equipment during operational transit.
F.
Two (2) copies of Medical Coaches’ Operator’s Manual shall be provided. Shall
include one (1) set of supporting manuals covering supplied items such as chassis,
generator, air conditioner, etc., if supplied.
G.
Install an access port within the compartment or compartment door of every
generator, electrical cable and plumbing compartment allowing the lead-in cable
and hoses to be connected to the unit with the main compartment doors closed and
locked.
“CASPIAN”
Specification
16.
11.
BODY EQUIPMENT:
All vehicle lights, reflectors, markings and wiring systems shall be in conformance with
D.O.T. Safety Regulations and State laws. The system shall be 12-volt. Lights shall not
be mounted on rub rails or vehicle bumper. An illuminated rear license plate holder shall
be furnished. Exterior lights shall be LED.
17.
18.
SPECIAL REQUIREMENTS:
A.
Details concerning colors, exterior painting, and lettering, etc., plus delivery of
completed unit to be arranged at a later date in accordance with buyer’s wishes.
B.
Due to variances in State and Local regulations, there may be some additional
options required for individual compliance. If compliance necessitates extra-cost
options, they will be quoted separately as necessary.
LIMITED WARRANTY:
Medical Coaches Incorporated offers a limited warranty on the mobile unit for twelve
(12) months or 12,000 miles. The warranty includes all equipment supplied by Medical
Coaches except those items which are covered by a separate warranty.
A detailed warranty statement shall be provided upon purchase or upon request.
“CASPIAN”
Specification
12.
OPTIONAL ITEMS :
CHECK IF
DESIRED:
A.
Lettering exterior body at sides, front and rear to buyer’s order (Special artwork
and emblems at extra cost.) ....................................................................................
B.
Paint body two-tone instead of standard one color ................................................
C.
Spare tire, wheel and carrier. (Includes hydraulic jack and tire tool) .....................
D.
Unit to be wired for 50-Hertz service (Export Only):
1. Generator to be de-rated to produce 220-volt, 50-Hertz, AC, 2-wire power.
Includes grounding rod with chain. All electrical equipment within body to
be equipped for 50-Hertz service ......................................................................
2. If any 110-volt equipment is to be installed, provide a 3,000-watt step-down
transformer and connections to 110-volt receptacles .......................................
E.
In order to permit the use of local power at specified locations, provide Russell &
Stoll, or equal, reverse service, waterproof receptacle with cover and back box for
installation in building ............................................................................................ F.
If above receptacle is provided, install matching 60-amp, reverse service waterproof connector on end of lead-in cable in place of alligator clips ........................
G.
Provide a 5-foot pigtail with connector on one end and alligator clips on the other
end, for use in locations where no installed receptacle is available, if “F” above is
provided ..................................................................................................................
H.
Public address equipment: Amplifier, microphone and one (1) exterior speaker .
I.
35-item tool kit contained in metal carrying case ...................................................
J.
24-unit first aid kit with all necessary bandages, antiseptics and burn ointments
contained in a steel box ..........................................................................................
K.
Provide a variable-speed, heavy-duty oscillating fan .............................................
L.
Provide one (1) folding aluminum table and two (2) steel folding chairs ..............
M.
Exterior Tent: To be a Eureka, Riverside, or equal, 9 feet x 12 feet with center
height of 7 feet 6 inches, full floor, door and three (3) large windows with storm
flaps. To be used for additional patient area or staff living area ...........................
N.
Fisher Micromaster I, or equal, binocular microscope with carrying case .............
O.
Army-style folding aluminum stretcher .................................................................
P.
Trauma Kit II, trauma/first aid kit, approximately 100 items. (List available upon
request.) ..................................................................................................................
“CASPIAN”
Specification
Q.
13.
Min-X-Ray Unit, Model H-500, 100 kV/30 mA with 300MS stand .....................
“ANGEL”
Mobile Hospital with Surgery
and 11-Bed Ward
Print #3245
Approximate Interior Dimensions
Length ……... 39’ 6” (12.04M)
Width ……....
7’ 6” ( 2.29M)
Height ……...
7’ 4” ( 2.24M)
1.
TRAILER AND BODY CONSTRUCTION:
A.
Trailer shall be a closed van, semi-trailer type, having a tandem axle and equipped
with air suspension.
B.
Wheels shall be equipped with 11R22.5 (14 ply) steel belted radial tires.
C.
Dual, 2-speed, vertical lift, front trailer supports with sand pads, lowering
mechanisms, and locking device, allowing no movement of the supports once in
place, shall be provided as standard equipment. The lift mechanism shall allow
the trailer to be raised above the horizontal position.
D.
There shall be sufficient “I” beam crossmembers and other reinforcement pieces
to insure that the trailer has adequate strength and rigidity to withstand all road
shocks and loading conditions. All chassis fabrication is to be of the highest
quality workmanship, assuring extreme durability.
E.
Trailer brakes shall be 16-1/2 by 7-inch, air-operated in conjunction with the
tractor brakes, and connected thereto by standard flexible hose connections. The
trailer brakes shall set automatically when it is disconnected from the tractor. The
braking system shall comply with all applicable federal laws in effect at the time
of delivery.
F.
The upper fifth wheel coupler of the trailer shall be of such a size as to completely
cover the fifth wheel of the towing tractor when coupled and turned at any angle.
The upper fifth wheel coupler shall be adequately reinforced on its upper surface.
080301/1765
399 Co Hwy 58 P.O. Box 129 Oneonta, New York 13820 (607) 432-1333 FAX (607) 432-8190
The global leader in “Custom Mobile Systems” since the 1940s …
Visit us on the Web at www.medcoach.com
“ANGEL”
Specification
1.
2.
TRAILER AND BODY CONSTRUCTION: Continued …..
G.
The trailer shall be equipped with a full width, steel rear bumper. The body shall
have reflective stripes to give an indication of the width of the trailer. The trailer
shall be furnished with mud flaps.
H.
General body wall construction shall consist of roll-formed “C” channels, 8.625
inch high by 1.75 inch deep, 3003-H14 aluminum alloy, .080 inch thick. The
channels shall run horizontally the entire length and width of the unit and shall be
secured to aluminum corner posts, roof rail and lower rail using 3/16-inch brazier
head aluminum rivets. Finished exterior body surfaces shall be smooth with no
rivets.
I.
The roll-formed “C” channels shall comprise the exterior body sides and end
panels. The channels shall be fastened together along their full length with
Plexus, or equal, high-performance adhesive specially designed for metal bonding
(same as widely used in transportation, marine, and aviation industries). The
bond formed has a tensile strength of approximately 2,500 PSI (strain-to-failure
ration greater than most commercial mechanical fasteners); temperature resistance
range of -67° F to +250° F; chemical resistance; high-fatigue endurance; and
impact resistance.
J.
Each wall section shall be reinforced with vertical aluminum members, which are
welded on a minimum of 48-inch centers.
K.
The roof carlines shall be aluminum extrusions, 6063-T6 alloy, which shall be
welded to the roof rail on 16-inch centers. The roof assembly shall consist of a
one-piece, .040-inch aluminum roof. Roof panel to be secured around perimeter
with adhesive and 3/16-inch brazier head aluminum rivets to aluminum extruded
roof rail.
L.
All window and door openings shall be framed with welded aluminum structures
and gusseted to prevent torsional twisting. Heavy-gauge metal tapping plates
shall be installed between frame members to secure heavy wall-mounted
equipment as per custom body floor plan. Around perimeter of interior body at
ceiling, an integral part of roof rail is provided to secure ceiling, side panels and
overhead cabinets. At ceiling, there shall be installed tapping plates to permit
positive securing of light fixtures.
M.
Floor crossmembers shall be 4-inch deep trailer “I” beams spaced on 16-inch
centers.
“ANGEL”
Specification
2.
3.
INSULATION:
Body shall be insulated on sides, ends, floor and ceiling with foamed-in-place urethane.
Insulation offers optimum environmental protection; adds support to sides, ends and roof;
prevents entrance of moisture; and acts as a sound retardant. (Minimum: R-12).
3.
4.
WALLS AND CEILING:
A.
The interior walls shall be lined for full width and length with 1/4-inch thick
laminated formica panels. Panels shall be secured with joiners, edgings and
moldings specifically designed for this purpose.
B.
Ceiling shall be surfaced with NUDO Products, FiberCorr, or equal, ceiling
panels, consisting of .090-inch FRP overlay laminated to a corrugated plastic
core.
FLOOR:
A.
Between cross sills, secure 26-gauge galvanized sheet to fully enclose floor area.
Above cross sills, secure 3/4-inch thick plywood which is laminated on both sides
with fiberglass-reinforced-plastic panels. The panel edges to be treated with
edge-sealer for water resistance. Underside of floor panels exposed to road shall
be sprayed with Quaker Koat, or equal, sound-deadening undercoating.
B.
Floor shall be surfaced with Armstrong, or equal, heavy-duty cushioned vinyl
linoleum.
“ANGEL”
Specification
5.
6.
7.
4.
PAINTING PROCEDURES:
A.
Body exterior shall be thoroughly cleaned, sanded and primed with PPG urethane
primer. Body shall be painted with two (2) coats of PPG polyurethane topcoat,
one color of buyer’s choice.
B.
Steel structural trailer chassis undercarriage shall be painted black.
C.
Body shall be undercoated with Quaker Koat, or equal.
ENTRANCE/EXIT DOOR(S):
A.
Doors shall be corrosion-immune, constructed of fiberglass-reinforced plastic
(FRP) with solid polymer reinforcement. Shall be insulated with structural
urethane and close on dust-sealing neoprene extrusions. Door(s) shall include
safety-glass window with designer venetian blinds. Door latch shall be a heavyduty, L-series mortise latch with keyed deadbolt lock meeting ANSI A156.13
requirements. Hinges shall be stainless steel, strap type. Suitable safety steps and
grab handles shall be installed at door locations.
B.
One (1) emergency exit door in Surgical Room to be provided.
C.
One (1) main entrance/exit door to be provided. One (1) double-opening door for
use during transit. One (1) sliding door for use during operation mode to reduce
loss of heat and/or air conditioning during stretcher loading/unloading.
PLATFORMS AND STAIRWAYS:
There shall be provided at curbside entrance/exit door(s) an aluminum safety-tread
platform. Platform shall be secured in extended position with removable legs directly to
ground. Provide lightweight portable stairs equipped with 6-inch adjustable neoprene
feet. Provide removable safety rails at platforms and stairs.
8.
WINDOWS:
Install Hehr, or equal, sliding safety-glass windows with insect screens within body sides.
All windows shall be equipped with designer venetian blinds of appropriate color to
complement interior décor.
“ANGEL”
Specification
9.
5.
ELECTRICAL SYSTEM:
Unit shall be wired to receive 4-wire, 120/240-volt, 60-Hertz, AC, single-phase, 100-amp
power from generator or local power source via lead-in cable. Necessary wiring shall be
provided for operation of 120/240-volt equipment where indicated.
10.
WIRING:
A.
All trailer wiring shall be NEC standard conduit with stranded wire or plastic
jacketed, non-metallic sheathed cable with ground. Wiring and related devices
shall be installed in a workmanlike manner, mechanically and electrically secure.
Items requiring periodic service shall be readily accessible and serviceable.
Wiring shall be protected by grommets when passing through structural members.
B.
Circuit breakers panel(s) of adequate capacity shall be installed at appropriate
locations within body and shall include:
1.
C.
D.
11.
Individual 120-volt circuits for utility equipment, lights, air conditioning
and receptacles.
2.
240-volt for electric heating units.
Duplex receptacles shall be provided in convenient locations within body interior
to conform to National Electric Code.
Provide 50-foot, 4-wire lead-in cable with waterproof receptacle on one end and
alligator clips on other end for connection to 120/240-volt power source. Cable
shall be sized to unit capacity.
LIGHTING:
A.
Fluorescent lights in standard 1-, 2-, or 4-tube fixtures shall be surface-mounted
on interior body ceiling within plastic diffuser panels or beneath cabinets above
work surfaces. Diffusers shall be equipped with latching device to prevent falling
in transit.
B.
12-volt dome lights shall be provided at each door entrance and within exterior
body compartments.
C.
Install a floodlight on unit exterior at each door entrance. Floodlight shall be
controlled by interior switch.
“ANGEL”
Specification
12.
6.
GENERATOR/GENERATOR COMPARTMENT: (Diesel Generator)
A.
Compartment shall be accessible from the rear via hinged, louvered doors
equipped with flush-mounted locks and holders in open position. Expanded metal
grilles shall be installed at curb and street sides. Hinged panels shall be provided
over the grille areas.
B.
Compartment shall be separated from remainder of trailer by floor-to-ceiling,
insulated partition. Partition shall be framed with aluminum members and
surfaced on the generator side with aluminum sheet.
C.
Provide a 30 kilowatt Detroit Diesel, or equal, 120/240-volt, 60 Hertz, singlephase, 4-wire, liquid-cooled diesel generator. Generator shall be shock-mounted
and equipped with remote controls, starting battery, critical area silencer, AC
instrument package, and air cleaner. Generator shall be installed for easy
servicing, proper heat and exhaust dissipation, and connected to installed tank for
fuel supply
D.
Generator shall be hard-wired to a three-position, manual transfer switch to
change power input from generator to local power source, if available.
E.
Flexible, stainless steel, seamless tubing shall be installed between the generator
manifold and the inlet of the critical area silencer.
F.
A remote start/stop switch shall be installed. The power shall be fed from the
transfer switch through a 100-amp circuit breaker box. One (1) 12-volt dome
light shall be installed in the ceiling of the compartment.
G.
A 100-gallon fuel tank, with gauge, shall be installed within trailer skirt.
H.
Inside of generator compartment shall be lined with TUFCOTE, or equal, noise
barrier material.
I.
Install a remote meter panel to include AC ammeter, meter switch, voltmeter, and
frequency meter.
“ANGEL”
Specification
12.
7.
AIR CONDITIONING/HEATING:
A.
Install five (5) Coleman, or equal, roof-mounted air conditioners with electric
resistance heat strip within reinforced roof section. Units shall be rated at 13,500
BTU cooling and 5,600 BTU heating; 120-volt.
B.
Due to the critical nature of proper environmental control in field surgical units,
five (5) roof-mounted air conditioning/heating units shall be utilized: two (2) in
surgical area, one (1) in nurse/receiving area, and two (2) in Pre-Op/Post-Op area.
Air conditioning capacity is approximately fifty percent (50%) greater than
necessary. Each air conditioning unit operates independently allowing for
alternates to function should one unit fail and need repair.
“ANGEL”
Specification
14.
8.
PLUMBING:
A.
The plumbing system shall be designed to receive water directly from local
sources or from the installed tank. Plumbing fixtures, devices and appurtenances
shall be supplied with water in sufficient volume and at pressures adequate to
enable them to function satisfactorily and without undue noise. All water piping
shall be subjected to adequate water and pressure tests to determine leakage or
loss in pressure.
B.
The plumbing system shall include:
1.
One (1) 40-gallon fresh water tank,
2.
One (1) 50-gallon wastewater tank with hose connection,
3.
One (1) Flojet, or equal, 120-volt heavy-duty water pump,
4.
One (1) 10-gallon electric water heater.
C.
The fresh water tank shall be installed within an insulated underbody skirt
compartment accessible through a hinged door with flush-mounted lock and
holding device for door in open position. Compartment shall be provided with
electric heater for winter protection against freezing.
D.
Fresh water tank shall be connected to water heater and water faucet at sink by
high pressure, polybutylene tubing.
E.
Plumbing system shall be equipped with check valves in accordance with
approved commercial practice.
F.
Provide one (1) 50-foot water hose and one (1) wastewater hose. Hoses to be
different sizes to prevent intermix.
G.
Install a dispenser for folding paper towels at each sink location.
H.
Waste water shall drain to waste tank or hose connection through corrosionresistant PVC tubing.
I.
Unit shall be equipped with a water pressure regulator and removable filter trap at
water inlet.
“ANGEL”
Specification
15.
9.
INTERIOR FURNISHINGS:
A.
Surgical Operating Room:
1.
Accessible through double-swinging doors equipped with locking device
on both sides. Doors shall be equipped with an aluminum kick-scuff plate
on both sides at bottom. Aluminum, stainless steel, or chrome hand push
plates shall be provided in the upper section of each swing door on both
sides.
2.
Floor to be anti-static linoleum or tile.
3.
One (1) surgical operating table to be all stainless steel with rectangular
base, casters for movement and mechanical floor jacks for immobilization,
fully hydraulic operated, with arm boards and foot extension. Positions
include Trendelenberg, Reverse Trendelenberg, chair, flex, lithotomy, and
table. Easily cleaned. Shampaine Surgi-Op 511, or equal, with accessory
pack (arm board, leg holders, crutch sockets, anesthesia screen, and foot
extension). Table height adjusts from 28-inches to 39-inches.
4.
Provide one (1) operating light and one (1) emergency lighting system in
case of power failure.
5.
Build stainless steel scrub-up sinks within formica surfaced work counter.
Shall include hot and cold water mixing faucet energized by foot pedals.
Storage cabinet above. Includes soap and scrub brush dispensers.
6.
Provide and secure a Harris, or equal, double bowl stainless steel solution
stand. Stand mounted on 2-inch conductive soft rubber easy-swivel ballbearing casters.
7.
Provide and secure one (1) Jackson, or equal, kick bucket with a 12-quart
stainless steel pail encircled with a conductive rubber bumper. Mounted
on ball-bearing conductive rubber casters.
8.
Provide and secure an anesthesia system which includes two-gas
anesthesia machine with ventilator; absorber; Halothane vaporizer; and
gas scavenger. Ventilator includes oxygen, volume, and pressure monitor.
Two (2) each “D” size oxygen and nitrous oxide cylinders, shall be
provided. FOR USE WITH NON-FLAMMABLE GASES ONLY.
SURGICAL ROOM IS NOT EXPLOSION-PROOF.
9.
Provide one (1) UMF 2218-5, or equal, lockable drug and supply cabinet
with drawers, shelf storage and counter top.
10.
Provide and secure a stainless steel Mayo stand and I.V. pole.
“ANGEL”
Specification
15.
10.
INTERIOR FURNISHINGS: Continued …..
A.
Surgical Operating Room: Continued …..
11.
Provide and secure a Wilson, or equal, stainless steel crash cart. Includes
three (3) full-width drawers, nylon rollers, and full-width storage compartment at bottom. Includes stainless steel Mayo attachment, double-hook
irrigator rod, adhesive rack, cardiac pressboard, oxygen tank holder, and
conductive casters.
12.
Oxygen delivery system to include oxygen tank, regulator, gauges, hoses,
masks, humidifier, resuscitator, inhalator, and flowmeter. Three (3) 6,000
liter each cylinders installed in under-floor compartment piped to two (2)
hospital outlets in surgical room. Includes remote gauge for contents
monitoring.
13.
Within curbside wall install emergency door to permit removal of
stretchers in an emergency.
14.
Provide one (1) ARTEMA, Cardio-Aid 100, or equal, defibrillator
mounted on shelf. Features include: high intensity display, heart rate readout, energy selector, lighted indicators, acoustic indications, manual/
synchronized selector, ECG screen, ECG input, safety paddles, charging
for 360 joules/6 seconds, coiled cables, discharge tester, paper recorder,
charger, battery, ECG/telemetry output, and automatic screen freeze
control.
15.
Wall mount one (1) double x-ray film viewer.
16.
Provide Min-X-Ray, H500, portable x-ray unit complete with cone and
adjustable light beam collimator.
17.
Provide portable surgical suction unit with wheeled cart, collection bottles,
catheters, and compressor.
18.
Provide one (1) wall-mounted stop clock; one (1) blood pressure
apparatus; collection jars; and one (1) oto/opthalmascope.
“ANGEL”
Specification
15.
11.
INTERIOR FURNISHINGS: Continued …..
B.
C.
Darkroom:
1.
Shall be fully enclosed by floor-to-ceiling partition. Accessible through
hinged light-tight door with light-tight louver in lower section.
2.
Build in formica surfaced counter for mounting of automatic x-ray film
developer.
3.
Wall-mounted safe-light.
4.
Install darkroom light-proof vent-axia fan in streetside wall.
5.
Provide one (1) film storage cabinet.
6.
Provide one (1) compact tabletop automatic film processor. Can process
up to sixty (60) 14-inch by 17-inch films/hour. Water consumption onehalf gallon per minute in operational mode (1.9 liters per minute). Water
temperature range 40 degrees to 90 degrees F (6 degrees to –32 degrees
C).
7.
Provide one (1) wall-mounted x-ray viewer.
Nurses Station:
1.
Provide stainless steel sink with foot controls, hot and cold water mixing
faucet, formica counter, and storage above.
2.
Provide full-height medical supply cabinet with lockable narcotics section,
multiple shelf and drawer storage.
3.
Provide fold-up writing desk.
4.
Provide one (1) 102-unit first aid kit (list attached).
5.
Provide one (1) Doctor’s Drug Administration Kit.
“ANGEL”
Specification
15.
12.
INTERIOR FURNISHINGS: Continued …..
D.
E.
Laboratory Area:
1.
Provide formica surfaced laboratory counter with storage below.
2.
Install underneath counter one (1) Jewett Model CT-1, or equal, blood
bank refrigerator. Includes visual chart temperature recorder and audible
alarm. Capacity sixty (60) 450 m. bags.
3.
Provide one (1) MDT Castle, GLS-10V, or equal, tabletop steam sterilizer.
4.
Provide one (1) Fisher, Micromaster EH, or equal, binocular lab
microscope with glass slides and slide covers.
5.
Provide one (1) clinical centrifuge.
6.
Provide one (1) small portable Bunsen burner with five (5) spare bottles
and one (1) stand.
7.
Provide glassware to include test tubes, centrifuge tubes, beakers, and
pipettes.
8.
Provide one (1) lab balance.
9.
Provide one (1) serological water bath.
Toilet/Shower Room:
1.
Fully enclosed with waterproof partitions and door.
2.
Chemical flush toilet with holding tank and dump valve, plus hose.
3.
Provide wall vent – power with cover.
4.
Provide wall-mounted shower head with hot and cold mixing valve.
5.
Provide toilet paper dispenser with waterproof cover.
6.
Provide soap tray.
“ANGEL”
Specification
15.
13.
INTERIOR FURNISHINGS: Continued …..
F.
Pre-Operation/Post-Operation 11-Bed Ward Area:
1.
Provide four (4) Ferno Model 30, or equal, wheeled all-level cots.
Includes 3-inch mattress, contour and Trendelenburg features, wheels,
handles, and wall mount.
2.
Above each of the three (3) wall cots shall be mounted two (2) Ferno
Model 108-AF folding canvas pole-type stretchers. Shall be placed on
hinged wall-mounted brackets. Total six (6) stretchers.
3.
Above one (1) rear-mounted cot shall be installed one (1) Ferno Model
108-AF folding canvas pole stretcher.
4.
Above each of four (4) wheeled cots shall be installed one (1) hospital
oxygen outlet and one (1) hospital suction outlet. Includes four (4) each
flowmeters, humidifiers, masks, suction jars, gauges, and catheters. Also
install four (4) hinged wall-mounted I.V. bottle holders.
“ANGEL”
Specification
16.
14.
MISCELLANEOUS:
A.
Two (2) 25,000-pound minimum capacity, geared leveling jacks with sand pads
shall be attached to the main structural members at trailer rear. Jacks shall be
designed to limit natural vibration during stationary service and to level the trailer
unit.
B.
Two (2) 2-1/2 pound dry chemical fire extinguishers shall be bracketed and
installed within body interior.
C.
A series of underbody storage compartments shall be provided. Accessible
through hinged doors with holding devices and flush-mounted chromed locks.
D.
Install coat hooks at convenient locations within body interior.
E.
Provision shall be made for securing all equipment during operational transit.
F.
Two (2) copies of Medical Coaches’ Operator’s Manual shall be provided. Shall
include one (1) set of supporting manuals covering supplied items such as chassis,
generator, air conditioner, etc., if supplied.
G.
Install an access port within the compartment or compartment door of every
generator, electrical cable and plumbing compartment allowing the lead-in cable
and hoses to be connected to the unit with the main compartment doors closed and
locked.
H.
Install sight levels at body side and rear to aid in leveling unit.
I.
Provide battery-powered emergency light in each room that can be activated in
case of power shortage.
J.
Provide three (3) portable oxygen resuscitators with two (2) cylinders, case,
gauges, masks, hoses, and demand valves.
K.
Provide portable air purifier for surgical room and Pre/Post-operation areas.
L.
Provide one (1) spare Ferno Model 108-AF folding canvas stretcher.
M.
Provide four (4) portable flashlights in case of power failure.
“ANGEL”
Specification
17.
15.
BODY EQUIPMENT:
All vehicle lights, reflectors, markings and wiring systems shall be in conformance with
D.O.T. Safety Regulations and State laws. The system shall be 12-volt. Lights shall not
be mounted on rub rails or vehicle bumper. An illuminated rear license plate holder shall
be furnished. Exterior lights shall be LED.
18.
19.
SPECIAL REQUIREMENTS:
A.
Details concerning colors, exterior painting, and lettering, etc., plus delivery of
completed unit to be arranged at a later date in accordance with buyer’s wishes.
B.
Due to variances in State and Local regulations, there may be some additional
options required for individual compliance. If compliance necessitates extra-cost
options, they will be quoted separately as necessary.
LIMITED WARRANTY:
Medical Coaches Incorporated offers a limited warranty on the mobile unit for twelve
(12) months or 12,000 miles. The warranty includes all equipment supplied by Medical
Coaches except those items which are covered by a separate warranty.
A detailed warranty statement shall be provided upon purchase or upon request.
“ANGEL”
Specification
16.
OPTIONAL ITEMS :
CHECK IF
DESIRED:
A.
Lettering exterior body at sides, front and rear to buyer’s order (Special artwork
and emblems at extra cost.) ....................................................................................
B.
Paint body two-tone instead of standard one color ................................................
C.
Install a BRAUN, or equal, hydraulic wheelchair lift within vehicle ....................
D.
Spare tire, tube, wheel with under-slung carrier .....................................................
E.
Unit to be wired for 50-Hertz service (Export Only):
1. Generator to be de-rated to produce 220-volt, 50-Hertz, AC, 2-wire power.
Includes grounding rod with chain. All electrical equipment within body to
be equipped for 50-Hertz service ......................................................................
2. If any 110-volt equipment is to be installed, provide a 3,000-watt step-down
transformer and connections to 110-volt receptacles .......................................
Lead-in Cable: Basic unit is equipped with a 50-foot lead-in cable. Provide an
additional 50-foot cable with waterproof connectors at both ends to provide
100-foot lead-in cable between unit and local power supply .................................
G.
In order to permit the use of local power at specified locations, provide a
waterproof receptacle with cover and back box for installation in building ..........
H.
Provide a 5-foot pigtail with connector on one end and alligator clips on the
other end, for use in locations where no installed receptacle is available, if “G”
above is provided ....................................................................................................
I.
If option “H” above is provided, install matching 100 amp, reverse-service,
waterproof connector on end of lead-in cable in place of alligator clips ...............
J.
In-Transit Power: Install an auxiliary 6.5-kilowatt, 120/240-volt generator
within an insulated compartment. Generator shall provide electrical power to
operate refrigerator, lights, and one (1) heater in-transit. Generator shall include
vacuum cooling, low oil pressure cut-off, starting battery, critical area silencer
and running time meter. Compartment shall include hinged doors equipped
with flush-mounted lock and ventilating grilles. Generator shall be connected to
installed 20-gallon fuel tank ...................................................................................
K.
Install master intercom system throughout mobile unit .........................................
L.
Provide a stereo AM/FM radio/compact disc player connected to overhead
speaker system. Includes body-mounted antenna ..................................................
M.
35-item tool kit contained in metal carrying case ...................................................
F.
“ANGEL”
Specification
17.
N.
24-unit first aid kit with all necessary bandages, antiseptics and burn ointments
contained in a steel box ..........................................................................................
O.
Trauma Kit II, trauma/first aid kit, approximately 100 items. (List available
upon request.) .........................................................................................................
P.
Towing Tractor: As per attached specification. Price upon request .....................
“VICTOR”
Mobile Field Hospital
Print #3506
Approximate Interior Dimensions
Length ……... 52’ 6” (16.00M)
Width …….... 11’ 6” ( 3.51M)
Height ……...
7’ 6” ( 2.29M)
1.
TRAILER AND BODY CONSTRUCTION:
A.
Trailer shall be a main frame, drop bed, closed van semi-trailer having a tandem
axle and equipped with an air suspension.
B.
Wheels shall be equipped with 225-70R 22.5, low profile steel belted radial tires.
C.
Dual, 2-speed, vertical lift, front trailer supports with sand pads, lowering
mechanisms, and locking device, allowing no movement of the supports once in
place, shall be provided as standard equipment. The lift mechanism shall allow
the trailer to be raised above the horizontal position.
D.
There shall be sufficient “I” beam crossmembers and other reinforcement pieces
to insure that the trailer has adequate strength and rigidity to withstand all road
shocks and loading conditions. All chassis fabrication is to be of the highest
quality workmanship, assuring extreme durability.
E.
Trailer brakes shall be 16-1/2 by 7-inch, air-operated in conjunction with the
tractor brakes, and connected thereto by standard flexible hose connections. The
trailer brakes shall set automatically when it is disconnected from the tractor. The
braking system shall comply with all applicable federal laws in effect at the time
of delivery.
F.
The upper fifth wheel coupler of the trailer shall be of such a size as to completely
cover the fifth wheel of the towing tractor when coupled and turned at any angle.
The upper fifth wheel coupler shall be adequately reinforced on its upper surface.
051501/2092
399 Co Hwy 58 P.O. Box 129 Oneonta, New York 13820 (607) 432-1333 FAX (607) 432-8190
The global leader in “Custom Mobile Systems” since the 1940s …
Visit us on the Web at www.medcoach.com
“VICTOR”
Specification
1.
2.
TRAILER AND BODY CONSTRUCTION: Continued …..
G.
The trailer shall be equipped with a full width, steel rear bumper. The body shall
have reflective stripes to give an indication of the width of the trailer. The trailer
shall be furnished with mud flaps.
H.
General body wall construction shall consist of roll-formed “C” channels, 8.625
inch high by 1.75 inch deep, 3003-H14 aluminum alloy, .080 inch thick. The
channels shall run horizontally the entire length and width of the unit and shall be
secured to aluminum corner posts, roof rail and lower rail using 3/16-inch brazier
head aluminum rivets. Finished exterior body surfaces shall be smooth with no
rivets.
I.
The roll-formed “C” channels shall comprise the exterior body sides and end
panels. The channels shall be fastened together along their full length with
Plexus, or equal, high-performance adhesive specially designed for metal bonding
(same as widely used in transportation, marine, and aviation industries). The
bond formed has a tensile strength of approximately 2,500 PSI (strain-to-failure
ration greater than most commercial mechanical fasteners); temperature resistance
range of -67° F to +250° F; chemical resistance; high-fatigue endurance; and
impact resistance.
J.
Each wall section shall be reinforced with vertical aluminum members, which are
welded on a minimum of 48-inch centers.
K.
The roof carlines shall be aluminum extrusions, 6063-T6 alloy, which shall be
welded to the roof rail on 16-inch centers. The roof assembly shall consist of a
.040-inch aluminum roof. Roof panels to be secured around perimeter with
adhesive and 3/16-inch brazier head aluminum rivets to aluminum extruded roof
rail.
L.
All window and door openings shall be framed with welded aluminum structures
and gusseted to prevent torsional twisting. Heavy-gauge metal tapping plates
shall be installed between frame members to secure heavy wall-mounted
equipment as per custom body floor plan. Around perimeter of interior body at
ceiling, an integral part of roof rail is provided to secure ceiling, side panels and
overhead cabinets. At ceiling, there shall be installed tapping plates to permit
positive securing of light fixtures.
M.
Floor crossmembers shall be 4-inch deep trailer “I” beams spaced on 16-inch
centers.
“VICTOR”
Specification
2.
3.
INSULATION:
Body shall be insulated on sides, ends, floor and ceiling with foamed-in-place urethane.
Insulation offers optimum environmental protection; adds support to sides, ends and roof;
prevents entrance of moisture; and acts as a sound retardant. (Minimum: R-12).
3.
4.
WALLS AND CEILING:
A.
The interior walls shall be lined for full width and length with ¼-inch thick
laminated formica panels. Panels shall be secured with joiners, edgings and
moldings specifically designed for this purpose.
B.
Ceiling shall be surfaced with NUDO Products, FiberCorr, or equal, ceiling
panels, consisting of .090-inch FRP overlay laminated to a corrugated plastic
core.
FLOOR:
A.
Between cross sills, secure 26-gauge galvanized sheet to fully enclose floor area.
Above cross sills, secure ¾-inch thick plywood which is laminated on both sides
with fiberglass-reinforced-plastic panels. The panel edges to be treated with
edge-sealer for water resistance. Underside of floor panels exposed to road shall
be sprayed with Quaker Koat, or equal, sound-deadening undercoating.
B.
Floor shall be surfaced with Armstrong, or equal, heavy-duty cushioned vinyl
linoleum.
C.
Floor in Surgical Room shall be surfaced with Armstrong, or equal, anti-static tile
or linoleum.
“VICTOR”
Specification
5.
6.
4.
PAINTING PROCEDURES:
A.
Body exterior shall be thoroughly cleaned, sanded and primed with PPG urethane
primer. Body shall be painted with two (2) coats of PPG polyurethane topcoat,
one color of buyer’s choice.
B.
Steel structural trailer chassis undercarriage shall be painted black.
C.
Body shall be undercoated with Quaker Koat, or equal.
ENTRANCE/EXIT DOOR(S):
Doors shall be corrosion-immune, constructed of fiberglass-reinforced plastic (FRP) with
solid polymer reinforcement. Shall be insulated with structural urethane and close on
dust-sealing neoprene extrusions. Door(s) shall include safety-glass window with
designer venetian blinds. Door latch shall be a heavy-duty, L-series mortise latch with
keyed deadbolt lock meeting ANSI A156.13 requirements. Hinges shall be stainless
steel, strap type. Suitable safety steps and grab handles shall be installed at door
locations.
7.
PLATFORMS AND STAIRWAYS:
There shall be provided at curbside entrance/exit door(s) an aluminum safety-tread
platform. Platform shall be secured in extended position with removable legs directly to
ground. Provide lightweight portable stairs equipped with 6-inch adjustable neoprene
feet. Provide removable safety rails at platforms and stairs.
8.
WINDOWS:
Install Hehr, or equal, sliding safety-glass windows with insect screens within body sides.
All windows shall be equipped with designer venetian blinds of appropriate color to
complement interior décor.
“VICTOR”
Specification
9.
5.
ELECTRICAL SYSTEM:
Unit shall be wired to receive 4-wire, 120/240-volt, 60-Hertz, AC, single-phase, 200-amp
power from generator or local power source via lead-in cable. Necessary wiring shall be
provided for operation of 120/240-volt equipment where indicated.
10.
WIRING:
A.
All trailer wiring shall be NEC standard conduit with stranded wire or plastic
jacketed, non-metallic sheathed cable with ground. Wiring and related devices
shall be installed in a workmanlike manner, mechanically and electrically secure.
Items requiring periodic service shall be readily accessible and serviceable.
Wiring shall be protected by grommets when passing through structural members.
B.
Circuit breakers panel(s) of adequate capacity shall be installed at appropriate
locations within body and shall include:
C.
D.
11.
1.
Individual 120-volt circuits for utility equipment, lights and receptacles.
2.
240-volt for air conditioning and electric heating units.
Duplex receptacles shall be provided in convenient locations within body interior
to conform to National Electric Code.
Provide 50-foot, 4-wire lead-in cable with waterproof receptacle on one end and
alligator clips on other end for connection to 120/240-volt power source. Cable
shall be sized to unit capacity.
LIGHTING:
A.
Fluorescent lights in standard 1-, 2-, or 4-tube fixtures shall be surface-mounted
on interior body ceiling within plastic diffuser panels or beneath cabinets above
work surfaces. Diffusers shall be equipped with latching device to prevent falling
in transit.
B.
12-volt dome lights shall be provided at each door entrance and within exterior
body compartments.
C.
Install a floodlight on unit exterior at each door entrance. Floodlight shall be
controlled by interior switch.
D.
Three (3) battery-operated emergency lights shall be installed within trailer.
Lights to operate in case of power failure. Batteries to be rechargeable. Light
fixtures to be equipped with on/off switch to prevent battery failure during transit
or storage condition.
“VICTOR”
Specification
12.
6.
DIESEL-POWERED GENERATOR:
At front of trailer, install one (1) 70-kilowatt diesel electrical generator mounted on open
tread-plate platform. Features to include: 4 cylinder diesel engine for high efficiency,
long term operation; starting battery and starting motor; air filters (heavy-duty for high
duct/sand conditions); governor; lubrication system (internal pump); solenoid fuel pump;
water temperature, oil pressure, battery charger, and ammeter gauges; critical area
silencing muffler; alarm circuitry for low oil pressure and water temperature shut-off;
frequency meter; voltage meter; and running time meter. Entire unit shock-mounted on
shear vibration isolators and includes weather-proof enclosure. 200-gallon fuel supply
allows for approximately 90 hours of independent operation. Fuel supply provided by
separate tank mounted behind generator.
13.
AIR CONDITIONING/HEATING/VENTILATION:
A.
There shall be installed at the front of the mobile unit two (2) Bard, or equal,
36,600 BTU cooling and 17,065 BTU heating, 230/208-volt, 60 Hertz, singlephase air conditioning units. Units shall be properly framed and connected to a
metal duct installed between the roof and the ceiling. Duct shall be insulated and
shall include adjustable air diffusers. Units shall be thermostatically controlled.
Condensate shall be dispensed via flexible tubing from air conditioners to ground.
Cooling capacity: 73,200 BTU total.
Heating capacity: 34,130 BTU total.
B.
Install four (4) thermostatically controlled, electric blower heaters throughout the
body interior. Each heater rated at a minimum of 3,400 BTU.
C.
Install a power exhaust fan within exterior wall of Restroom.
D.
Within exterior wall of Darkroom, install a Vent-Axia, or equal, darkroom
exhaust fan.
“VICTOR”
Specification
14.
7.
PLUMBING:
A.
The plumbing system shall be designed to receive water directly from local
sources or from the installed tank. Plumbing fixtures, devices and appurtenances
shall be supplied with water in sufficient volume and at pressures adequate to
enable them to function satisfactorily and without undue noise. All water piping
shall be subjected to adequate water and pressure tests to determine leakage or
loss in pressure.
B.
The plumbing system shall include:
1.
One (1) 100-gallon fresh water tank,
2.
One (1) 40-gallon black water waste tank with hose connection,
3.
One (1) 60-gallon gray water waste tank with hose connection,
4.
One (1) Flojet, or equal, 120-volt heavy-duty water pump,
5.
One (1) 6-gallon electric water heater.
C.
The fresh water tank shall be installed within an insulated rear compartment
accessible through a hinged door with flush-mounted lock and holding device for
door in open position. Compartment shall be provided with electric heater for
winter protection against freezing.
D.
Fresh water tank shall be connected to water heater and water faucet at sink by
high pressure, polybutylene tubing.
E.
Plumbing system shall be equipped with check valves in accordance with
approved commercial practice.
F.
Provide one (1) 50-foot water hose and two (2) waste water hoses. Hoses to be
different sizes to prevent intermix.
G.
Install a dispenser for folding paper towels at each sink location.
H.
Waste water shall drain to waste tank or hose connection through corrosionresistant PVC tubing.
I.
Unit shall be equipped with a water filter with replaceable filter element.
“VICTOR”
Specification
15.
8.
OXYGEN/SUCTION/MEDICAL AIR SYSTEMS:
A.
B.
C.
Oxygen System:
1.
Two (2) “E” size oxygen tanks shall be installed in rear mechanical room.
Cylinders shall be equipped with manifold, regulators, and gauges as
required.
2.
Oxygen shall be piped to outlets in Post-Op Area and Surgical Room
through hospital grade tubing.
Medical Air System:
1.
Two “E” size air tanks shall be installed in rear compartment. Cylinders
shall be equipped with manifold, regulators, and gauges as required.
2.
Air shall be piped to Post-Op Area and Surgical Room through hospital
grade, high pressure tubing.
Suction System:
1.
Install one (1) E.M.S.E., or equal, dual head vacuum pump within rear
compartment.
2.
Vacuum piping shall be directed to outlets located in Post-Op Area and
Surgical Room.
“VICTOR”
Specification
16.
9.
INTERIOR FURNISHINGS:
A.
B.
Pre-Op and Post-Op Room:
1.
Shall be separated from remainder of trailer by floor-to-ceiling partition
with access through ceiling-mounted draw curtain.
2.
At the head of each bed build in a formica surfaced shelf.
3.
Above shelves install overhead storage cabinets with hinged door access.
4.
Each intensive care bed shall be enclosed by a hospital-type privacy
curtain.
5.
Install an oxygen, suction, and medical air outlet at the head of each bed.
6.
Provide tapping plates, securing devices, and electrical connections for
proper installation of beds and hospital equipment.
Restroom:
1.
Shall be enclosed by floor-to-ceiling partition with access through hinged
door.
2.
Install Thetford, Aqua-Magic, or equal, self-contained flush toilet.
3.
Install a stainless steel sink with hot and cold water faucet.
4.
Provide toilet accessories, to include: mirror, coat hooks, paper towel
holder, and toilet paper holder.
5.
Install 120-volt power exhaust vent within exterior wall.
6.
Install fiberglass shower stall with water-saver showerhead. Access
through shower curtain from toilet area.
“VICTOR”
Specification
16.
10.
INTERIOR FURNISHINGS: Continued …..
C.
D.
E.
Darkroom:
1.
Room shall be fully enclosed by floor-to-ceiling partition with access
through hinged door with light-tight louver in lower section.
2.
Build in formica surfaced work counter with storage under.
3.
Above counter install overhead storage cabinets with hinged door access.
4.
Install Vent-Axia, darkroom fan within exterior wall.
5.
Install darkroom safelight on wall above developer.
6.
Install Bar-Ray, or equal, tilt x-ray film storage cabinet.
7.
Provide tapping plates, securing devices, electrical connections and
plumbing connections for proper installation of x-ray film processor.
Lab Area:
1.
Build in formica surfaced laboratory counter with storage under counter.
2.
Above counter install overhead storage cabinets with hinged door access.
3.
Provide tapping plates, securing devices, and electrical connections for
proper installation of laboratory equipment.
4.
Provide and secure an upholstered, castered laboratory stool with backrest.
Nurse Station:
1.
Provide a formica surfaced desk section with center drawer.
2.
Above desk install an overhead storage cabinet with hinged door access.
3.
Provide and secure an upholstered, castered secretarial stool with backrest.
4.
Provide and secure two (2) upholstered chairs outside of Darkroom.
“VICTOR”
Specification
16.
11.
INTERIOR FURNISHINGS: Continued …..
F.
Surgical Room:
1.
Room shall be enclosed by floor-to-ceiling partition with access through
double swinging doors with latching device on both sides. Doors shall be
equipped with an aluminum scuff plate on both sides at bottom. Polished
aluminum hand push plates shall be installed on each side of each door.
2.
Exterior walls, floor, and partition shall be lead-lined in accordance with
USFDA requirements.
3.
Install a leaded curtain to cover swinging door opening. (Doors shall not
be leaded.)
4.
Build in formica surfaced counter. Within counter, install two (2)
stainless steel scrub sinks with hot and cold water faucets. Sinks to have
gooseneck faucets with foot pedal controls.
5.
Install scrub brush dispenser and hand soap dispenser on wall above sinks.
6.
Across front wall build in floor-to-ceiling storage closets. The center
closet shall be accessible through hinged door and shall house the
electrical distribution panel(s). The streetside section shall be equipped
with adjustable shelves and have access through louvered, folding doors.
The curbside section shall have a coat bar and shall also be accessible
through louvered, folding doors.
7.
Install two (2) oxygen outlets, two (2) suction outlets, and one (1) medical
air outlet on streetside wall.
8.
Provide tapping plates, securing devices, and electrical connections for
proper installation of surgical equipment.
“VICTOR”
Specification
17.
12.
MECHANICAL ROOM:
A.
Utility area shall be provided at body rear with access through exterior door.
B.
Compartment shall be utilized for installation of water inlet, fresh water tank,
water heater, water pump, vacuum pump, oxygen bottle manifold system, medical
air bottle manifold system, and miscellaneous equipment storage.
C.
Install in compartment a 120-volt light for nighttime illumination. Includes on/off
switch.
D.
Provide 240-volt electric fan, blower heater for freeze protection. Heater to be
equipped with fan only/fan heater switch to provide compartment ventilation
when heat is unnecessary. (Fasco, or equal.)
“VICTOR”
Specification
18.
13.
MEDICAL EQUIPMENT:
A.
B.
Pre-Op and Post-Op Room:
1.
Three (3) Simmons Healthcare, Varicare II, or equal, manual stretcher
beds with 4-inch mattress and full length side rail.
2.
Two (2) Amedco Healthcare, or equal, manual crank special care beds
with inner-spring mattress, mattress cover, and evacuation handles.
3.
Five (5) Amedco Healthcare, or equal, automatic lift over-bed tables.
4.
Two (2) Transpack, Model 2, or equal, ventilators.
5.
Two (2) Propaq 102, or equal, portable patient monitors with LCD screen.
6.
One (1) BCI International, Model 3040, or equal, Microspan Pulse
Oximeter with patient cable and manual.
7.
One (1) Artema, Cardio-Aid 100, or equal, portable defibrillator/ECG
monitor with cart and strip recorder.
8.
Five (5) Rico, Model RS-4XP, or equal, aspirators.
9.
One (1) Baum, or equal, standby baumanometer.
10.
One (1) Ferno, Model 60, or equal, aluminum long back board.
11.
One (1) deluxe trauma kit.
12.
One (1) drug kit.
13.
Five (5) flowmeters with Ohio adapter.
14.
Five (5) reusable humidifiers.
15.
Five (5) hospital suction kits with Ohio adapter.
16.
One (1) Health Care Logistics, or equal, stainless steel utility cart.
Darkroom:
1.
One (1) AGFA, CP1000, or equal, x-ray film processor with two (2) waste
bottles, one (1) case of developer, and one (1) case of fixer.
2.
One (1) Wolf, or equal, analog lever timer.
“VICTOR”
Specification
18.
14.
MEDICAL EQUIPMENT: Continued …..
C.
Laboratory:
1.
One (1) Jewett, Model CT-1, or equal, blood bank refrigerator with
temperature monitor and 7-day recording thermometer.
2.
One (1) Milton Roy, Spectronic 20-D, or equal, spectrophotometer.
3.
One (1) Instrumentation Laboratory, System 1304, or equal, blood gas
analyzer with sample injector and gas regulators.
4.
One (1) Baxter, Sysmex F-300, or equal, hematology analyzer with diluter
system.
5.
One (1) Castle, GLS-10V, or equal, tabletop steam sterilizer.
6.
One (1) Fisher, Micromaster I, or equal, binocular microscope.
7.
One (1) triple-beam balance with flat platform and tare bar.
8.
One (1) auxiliary weight set.
9.
One (1) Rh-typing viewer.
10.
One (1) agglutination tube viewer.
11.
One (1) hematology mixer.
12.
One (1) microhematocrit centrifuge with rotor, 240-volt, 60 Hertz.
13.
One (1) microcapillary tube reader.
14.
One (1) gross microslides, plain glass (75 x 25mm).
15.
One (1) pack cover glasses, (22 x 22mm) 4 ounces per pack.
16.
One (1) pack Securline Marker II (10 per pack).
17.
One (1) pack hematocrit tube sealant (10 per pack).
18.
One (1) pack capillary tubes, red (200 per pack).
19.
One (1) pack capillary tubes, blue (200 per pack).
20.
One (1) pack self-sealing tourniquets (12 per pack).
21.
One (1) Autolet Mark II.
22.
One (1) pack yellow platforms (200 per pack).
23.
One (1) case sample cups (144 per case.)
“VICTOR”
Specification
18.
15.
MEDICAL EQUIPMENT: Continued …..
C.
D.
Laboratory: Continued …..
24.
One (1) urine collection and analysis systems, to include:
One (1) case collection packs (500 per case),
One (1) pack Urisystem tubes (500 per pack),
Two (2) packages Urisystem stain (4 per pack),
One (1) Urisystem rack,
One (1) pack Urisystem 10 test slides (100 per pack).
25.
One (1) case MIF procedure kit (20 per case).
26.
One (1) Flo-Thru total solids meter.
27.
One (1) laboratory counter (6 unit).
28.
One (1) ultrasonic cleaner, Model FS14.
29.
One (1) basket for FS14.
Surgical Room:
1.
One (1) Shampaine, Model 511, or equal, surgical table with the following
accessories: anesthesia screen, body restraint strap, Bierhoff knee
crutches, and armboard.
2.
One (1) Castle, Model 2420C, or equal, minor surgical light.
3.
One (1) Bovie Specialist, or equal, electrosurgical unit with cart.
4.
One (1) Clifford Mayo stand.
5.
One (1) Jackson kick bucket.
6.
One (1) double solution stand.
7.
Two (2) 4-leg, 2-hook, I.V. stands.
8.
One (1) Health Care Logistics, or equal, stainless steel utility cart.
9.
One (1) MIE Cavendish 230, or equal, 2-gas anesthetic apparatus with
mobile frame, oxygen lines, nitrous oxide lines, and vaporizer.
10.
One (1) Waterloo, or equal, 5-drawer emergency cart.
11.
One (1) Rico, Model RS-4XP, or equal, aspirator.
12.
Two (2) Ambumatic, or equal, automatic resuscitators.
“VICTOR”
Specification
18.
16.
MEDICAL EQUIPMENT: Continued …..
D.
Surgical Room: Continued …..
13.
One (1) flowmeter with Ohio adapter.
14.
One (1) reusable humidifier.
15.
One (1) hospital suction kit with Ohio adapter.
16.
One (1) Artema, Cardio-Aid 100, or equal, portable defibrillator/ECG
monitor with cart and strip recorder.
17.
One (1) Allied Healthcare, Model 601U, or equal, gastric drainage pump
with glass bottle and cart.
18.
One (1) General Electric, or equal, mobile x-ray unit.
19.
One (1) dual panel, Trimline x-ray film illuminator.
20.
One (1) Tri-Pack x-ray apron rack.
21.
One (1) Easy-Wrap x-ray apron.
22.
One (1) pair Duoflex protective gloves.
“VICTOR”
Specification
19.
17.
MISCELLANEOUS:
A.
Two (2) 25,000-pound minimum capacity, geared leveling jacks with sand pads
shall be attached to the main structural members at trailer rear. Jacks shall be
designed to limit natural vibration during stationary service and to level the trailer
unit.
B.
Two (2) 2-1/2 pound dry chemical fire extinguishers shall be bracketed and
installed within body interior.
C.
A series of underbody storage compartments shall be provided. Accessible
through hinged doors with holding devices and flush-mounted chromed locks.
D.
Install coat hooks at convenient locations within body interior.
E.
Provision shall be made for securing all equipment during operational transit.
F.
Two (2) copies of Medical Coaches’ Operator’s Manual shall be provided. Shall
include one (1) set of supporting manuals covering supplied items such as chassis,
generator, air conditioner, etc., if supplied.
G.
Install an access port within the compartment or compartment door of every
generator, electrical cable and plumbing compartment allowing the lead-in cable
and hoses to be connected to the unit with the main compartment doors closed and
locked.
H.
Install sight levels at body side and rear to aid in leveling unit.
“VICTOR”
Specification
20.
18.
BODY EQUIPMENT:
All vehicle lights, reflectors, markings and wiring systems shall be in conformance with
D.O.T. Safety Regulations and State laws. The system shall be 12-volt. Lights shall not
be mounted on rub rails or vehicle bumper. An illuminated rear license plate holder shall
be furnished. Exterior lights shall be LED.
21.
22.
SPECIAL REQUIREMENTS:
A.
Details concerning colors, exterior painting, and lettering, etc., plus delivery of
completed unit to be arranged at a later date in accordance with buyer’s wishes.
B.
Due to variances in State and Local regulations, there may be some additional
options required for individual compliance. If compliance necessitates extra-cost
options, they will be quoted separately as necessary.
LIMITED WARRANTY:
Medical Coaches Incorporated offers a limited warranty on the mobile unit for twelve
(12) months or 12,000 miles. The warranty includes all equipment supplied by Medical
Coaches except those items which are covered by a separate warranty.
A detailed warranty statement shall be provided upon purchase or upon request.
“VICTOR”
Specification
19.
OPTIONAL ITEMS :
CHECK IF
DESIRED:
A.
Lettering exterior body at sides, front and rear to buyer’s order (Special artwork
and emblems at extra cost.) ....................................................................................
B.
Paint body two-tone instead of standard one color ................................................
C.
Install a Braun, or equal, hydraulic wheelchair lift within vehicle .........................
D.
Spare tire and wheel with underslung carrier .........................................................
E.
Heavy-duty electro-hydraulic leveling jacks ..........................................................
F.
Unit to be wired for 50-Hertz service (Export Only):
1. Generator to be de-rated to produce 220-volt, 50-Hertz, AC, 2-wire power.
Includes grounding rod with chain. All electrical equipment within body to
be equipped for 50-Hertz service ......................................................................
2. If any 110-volt equipment is to be installed, provide a 3,000-watt step-down
transformer and connections to 110-volt receptacles .......................................
G.
Lead-in Cable: Basic unit is equipped with a 50-foot lead-in cable. Provide an
additional 50-foot cable with waterproof connectors at both ends to provide
100-foot lead-in cable between unit and local power supply .................................
In order to permit the use of local power at specified locations, provide a Russell
& Stoll, or equal, reverse-service, waterproof receptacle with cover and back box
for installation in building ......................................................................................
Provide a 5-foot pigtail with connector on one end and alligator clips on the
other end, for use in locations where no installed receptacle is available, if “H”
above is provided ....................................................................................................
J.
If “I” above is provided, install matching 200-amp, reverse-service, waterproof
connector on end of lead-in cable in place of alligator clips ..................................
K.
In-Transit Power: Install within an insulated compartment an auxiliary 6.5kilowatt, 120/240-volt generator. Generator shall provide electrical power to
operate refrigerator, lights, and one (1) heater while in-transit. Generator shall
include vacuum cooling, low oil pressure cut-off, starting battery, critical area
silencer, and running time meter. Compartment shall include hinged doors
equipped with flush-mounted lock and ventilating grilles. Generator to be
connected to installed 20-gallon fuel tank ..............................................................
L.
Install master intercom system throughout mobile unit .........................................
M.
Provide a stereo AM/FM radio/compact disc player connected to overhead
speaker system. Includes body-mounted antenna ..................................................
N.
35-item tool kit contained in metal carrying case ...................................................
H.
I.
ill response to your recent request, we are pleased to enclose a literature package for your
review. The drawings and specifications enclosed illustrate several designs for trailer and selfpropelled Mobile Dental Clinics that could be used (or modified) to meet the needs of your
clients.
If you require a special design, please complete the enclosed Questionnaire and return it
with a rough sketch and/or brief description of your proposed layout and equipment
requirements. We can then prepare a complete proposal for your use.
The cost of a mobile unit will depend on size, configuration, utility requirements, and
equipment requirements. To give you an idea of cost, the following are budgetary prices for
several models. These prices do not include the cost of the dental equipment or a towing vehicle
for the trailer models.
A.
B.
C.
D.
E.
"NORFOLK"
"PRASAD PROJECT II"
"GLENS FALLS"
"JEFFERSON COUNTY"
"PONCHARTRAIN"
F. "MT. WHITNEY"
G. "ON-SITE III"
$240,000 to $250,000.
$275,000 to $285,000.
$220,000 to $235,000.
$225,000 to $240,000.
$240,000 to $250,000.
(Plus: generator, if required)
$260,000 to $275,000.
$285,000 to $300,000.
MEDICAL COACHES ' STANDARD PACKAGE
UNIT
COST:
2-CHAIR
CHAIR:
A-DEC, Cascade 1040 chair with automatic positioning
and
return
.. .. . . . . . . .. . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
;
$7,180.00 $14,360.00
UNIT:
A-DEC,Radius2122 chair-mountedunit with three (3)
automatichandpiececontrolsand tubing,foot control,
adjustabletray, assistant's instrumentationand stainless
steel utility center
...................................
.............
DENTALLIGHT:
A-DEC, Radius6300 dentallight,unit mounted ...........
$6,050.00 $12,100.00
$2,460.00 $4,920.00
STOOLS:
A. Doctor's stool:A-DEC,Model 1601doctor's stool
with Integralgas cylinderadjustmentand carpet
..........................................................
$725.00
$1,450.00
$835.00
$1,670.00
$750.00
$1,500.00
........... .....
$3,940.00
$4,555.00
AUTOCLAVE:
Pelton & Crane,DeltaXL 10,fully automatic ..............
$4,100.00
$4,100.00
casters
B. Assistant's stool:A-DEC,Model 1626assistant's stool
with body support,gas cylinderadjustment,with foot
rest and caJl)et casters
.......................................
INSTRUMENTCABINET:
A-DECdentalunit built in undercounter......
AIR COMPRESSOR:
Air Techniques,AirStar,oil-lessdentalair system, 115volt. (Model 10for one-chairclinic;Model21 for twochair clinic.) Includes sound reducing cover
.PACKAGE COST: $26,040.00
$44,655.00
OPTIONAL DENTAL EQUIPMENT
UNIT
COST:
A. X-RAY & FILM PROCESSING EQUIPMENT:
1. GENDEX GX770 wall-mounted x-ray with remote control
Danel
......................................................................
$4,360.00
2. Air Techniques Peri-Pro III, dental x-ray film processor;
including daylight loader .... .... ......... ..... .......... ..............
$2,620.00
3. Air Techniques NT 2000XR automatic film processor for all
size films; includes:
automatic replenisher...................................................
$7,100.00
$945.00
Panoramic daylight loader. ... .......... ........ ... ... .......... ......
$90.00
4. Dental x-ray film dispenser, Kodak:Model 2 ....... ...... ..........
$165.00
5. Dental view box (wall or desk mounted) ........... .................
6. Ceiling-mounted lead curtain for radiation protection; 3 feet
$330.00
wide (Bar-Ray) .........................................................
B. CENTRAL VACUUM SYSTEMS:
1. A-DEC Air Vacuum System (AVS) with air saliva ejector
and oral evacuator hoses. (Operates from air compressor.)
Each Chair: $1,440.00
2. Dentsply MVS Central Evacuation System, two Dumpunit. . .. . $4,225.00
3. Steri-Dent, STERI-VAC with spare motor, canister, and low
voltage relay. (For units without outside water source.) ......... $2,070.00
C. ADDITIONAL OPTIONS:
1. A-DEC mobile dental cabinet, Model 2644. Oregon style
with sliding top, three shallow drawers and two deep drawers . $1,085.00
2. Dentsply/Cavitron
3. CAULK,
PROMIX,
Select, ultrasonic scaler. . ... ... ... .. .... ... .. .. $1,350.00
variable
speed amalgamator..
.. . .. . . . . . . . .. .
$750.00
27-FOOT
BODY
MOUNTED
ON A TILT-CAB
CHASSIS
(
r
,
1 OVERALL LENGTH
:35'0" 1
1 OVERALL WIOTH
... S'O-I
1 OVERALL HEIGHT ... 12'S"I
L
J
FOR
UNITED
26' 6"
s oeM.
~r: ~r
1'33
g':3"
S'~.-73 .
3M
4
82M
eXHAUST
FAN~
1:>-
MQBIL.S
IN$TRUMEIN
CAsIN,"
eCUIPMENT
I
I
I
I
7'6"
2.2QM.
\
\
ACCESS TO
GENERATQR
OvE
EAO STO"ACE
- -FIL.E
-
1
OVERHEAD
STO"ACE
1
1
I
I
,
~~
COUNTE..
~NK
SINIC COUNTER
~v~"~O_~_
S~O:-G~
_ _
~Tr:.I=.E~ ~OEM...J
REPRIOIRATCR
CENTAI..
UNIT
rL____
c-"'s-;RE.
L.OUNGe SEAT
I
~g~~~~
I;:A
C:L.OSET
ABove
COuNTeR
Q ~IB
~
1/
r
WAL.L-MOUNTEO
DENTAL.
X-IitAY
'
Il O:~6~1 A"IJ
........
L.EAOEO
CURTAIN
1- _
CURTAIN
-+
~ ~~T~N~ ~R~~
....-
e
rOENTAI.. ROOM "S" ,
L.:
J
STEPS
r
- - - - - - - - - - - - -.'
I INTERIOR
I
l
HEIGHT
82"1
a.oeM!
J
2~CHAIR DENTALCLINIC
AL.CO
28
ceSCRIPTION
r.. .
'N
m
lI
l:J
H
W
I
III
I
"
, 18
ITI"
m
o
H
III
W
IZ
H
CD
..
..
W
...
..
r-llfJ
'"
, Im
.
D
N
ee
u.
w
L! I
t
1
w I..w
I
IS
c>
we
.."
a~
I
'"
t
ITIpj
III
i
LJ
. <~
~...
~z
<w
~D
:
I
I
;::t
..t;
..
W
W"CD
1\1
>..
Cc
-
~W..
"W
Zz
:JW
EJ"
ell<
..c ..
..e
....
WW
uZ
uW
e"
I
(I
, ~
10"
34'4"
lQ.04e1M.
r-5'O"~
I
I .S2M.
I
STORAGE
CABINETS
1 O~~~~~a~
L
I
1
L
1
...J
L______
1 OVERHEAO STORAGE
_ _ _ ..J COUNTER
OVERHEAD STORAGe
-----WDRIC
COUNTER
EXHAUST
~AN
ACCESS
13'6"
COUNTER
""
Ii!
iREce~TION£STi
~D~R~~O~M~
DENTAL..
UNIT
CENTAL.
UNIT
_ ~U.!:!T!!, _
TO
UTIL.ITY
COMPARTMENT
~IL.E
CABINET
I
L
1
...J
L
OVERHEAD
STORAGE
~f;!~A-8
I
:2.QOM.
I
I
e
!AUTCC"i:AvE!
FORMICA
CDUNTER
L ..AB~ _ .J
~ORMICA
COUNTER
r iJE-;'TA~
- -,
1STATION
1/:31
L
J
e
r DENTAL ,
1STATION #21
L__~
J
r
r iJE-;'TA~ - -,
ISTATION 1111
L
J
FOL.OING
OOOR
,
I WAITING I
L... _A~E~ -I
AIR CONDITIONER
STEP'S
r
,INSIDE
L
HEIGHT
...
,
84"1
_ _ _ _ _ _ _ _ _ _2:..,'
~M..:J
STEPS
American Bio-Medical Service Corporation (ABMSC) has developed the most advanced, fully self-sustaining, mobile
medical care facility known to date. Currently, there are no other certified commercial transportable medical units
available with the self-sufficiency, mobility, and design flexibility.
As a fully functioning, self-sustaining mobile surgical/medical center, the mobile unit requires very little setup time and
comes equipped with security and monitoring systems. The spacious design flows from room to room offering a
comfortable environment for patients and staff. These modular units can be modified to create ancillary facilities, such as
housing or teaching units for staff and patients.
All models are mobile and capable of being transported by cargo ships, overland haulers, or military helicopters. Each
mobile unit can remain on its own axle or can be installed on a foundation for semi-permanent or permanent use. The units
can also be linked to form a modular building complex, such as a full-fledged hospital.
Features
•
•
•
•
•
•
•
The mobile unit can be connected to local commercial utility power. (Back-up power will automatically kick in if
interrupted.)
The generator is capable of continuous 24-hour operation for one week using diesel fuel.
Self-contained fresh water supply; black and grey waste tanks all concealed under unit.
Redundant air-conditioning system with five fan-coils and individually controlled temperature zones.
On-demand electric water pump used for all sinks, water heater, and toilets; built-in 10-gallon water heater.
Fully installed medical gas and vacuum system (includes manifold, monitors and alarm system).
Complete security systems with outside remote camera system.
Custom Construction
•
•
•
Exterior can be modified to customer color or design (i.e., national flag, etc.) specifications.
Built specifically to handle the rigorous conditions found in disaster areas or environmentally hostile locations.
Entire undercarriage can be insulated and sealed against severe climatic conditions.
•
•
Flooring finish is hospital grade vinyl (seamless, welded) for the reduction of bacterial and contamination concerns.
Fitted with universal tie-down points and four pick up points for crane or helicopter transport.
Annex (1)
Truck Specifications
Item
Number
Manufacturer
Country
Model
Description
Qty
Truck
Freightliner
4900SA
Truck: 6 x 6
Engine: V shape 8cc
Horsepower: 500 minimum
Engine: turbo charger
Engine cooling: via a cooler not
Less than 100 liters in capacity.
Gearbox: full automatic with
16 front speeds and one rear
speed.
Tires and rims: minimum 10
tires, size R20/1400XZL,
TUBELESS PR 22 with rims
iron sheet plus a spare tire of
the same size, fitted with
loading and unloading winch.
Diesel tank: capacity minimum
600 liters
Steering wheel: hydraulic
Annex (1)
Truck Specifications
10
Annex (2)
Field hospital specifications (trailed - borne)
(12) Trailers representing clinics medical wards and their annexes (the table below).
(4) multi-purpose tents
Corridors and connectors sufficient to set up the closed hospital.
Integrated kitchen.
Integrated air-conditioning system.
Medical gases system.
Medical systems and furniture.
S.N.
1
2
3
4
5
6
7
8
9
10
11
12
CONTAINER PURPOSE
Operation room
Intensive care room
Emergency suite
Administrative office (command)
X-ray room
Laboratory and sterilization room
Pharmacy room
Dentistry room
Ophthalmology
ENT room
Maternity suite
Kitchen suite
The specifications for the multi-purpose tents:
1. Fire-resistant.
2. Each tent should not be less than 48 meters in space.
3. Can be used as a basic clinic, exchange and sorting area, emergency or
inpatient clinic.
4. Easy to install and dismantle.
5. Easy to supply with electricity and air conditioning.
6. Weather proof.
7. Durable and robust.
8. Inflatable
Annex (2)
Field hospital specifications (trailed - borne)
(continued)
The specifications required for the corridors and connectors:
The specifications in this area are open according to the supplier's own style. However,
it is to be taken into consideration, the good design and form, lighting, airconditioning, heavy duty capacity to bear the work pressure and patient numbers.
The specifications required for the containers:
Possibility to transport by ****C.-130 transport aircraft .
Possibility of all containers to be transported by ships.
Possibility of all containers to be borne or towed by trucks.
Trailers must have characteristics of robustness, durability, ease of movement,
endurance of movement, shaking and shocks.
5. Trailer shall bear the harsh climatic conditions and temperatures and shall be
compatible with military standards.
6. The trailer shall be thermally insulated with nonpoisonous strong and fireresisting internationally approved material.
7. The x-ray trailer shall be insulated with lead according to standard specifications.
8. Trailer weight shall be suitable not exceeding in any case 6 tons when empty and
not exceeding 10 tons with full load and contents.
9. Easy dismantling, deployment, use and application.
10. Sufficient and properly insulated doors and windows with taking in consideration
the future need for additional doors in case of connecting containers to form a
closed hospital.
11. Sufficient electrical fittings and numbers of sockets for medical systems. The
available voltage must meet the technical requirements of the equipment and be
of internationally recognized medical installation quality.
12. Sufficient, proper, easy to install and service lighting inside trailer. In addition
the lighting in the operations and intensive care rooms shall be of washable and
sterilizable type.
13. The Trailer shall have all necessary non medical necessary connections (such as
electricity, water and sanitary drainage networks).
14. The Trailer shall have all the necessary medical extensions (such as oxygen
network, compressed air...etc.), and their locations inside the trailer shall be
compatible with their purpose
15. The Trailer shall have AUTO STEAL FOOT hydraulic lifting and lowering
system for each container, fixed at each of the four container corners, raised from
the ground by a distance minimum ½ meter.
Field hospital specifications (trailed - borne)
(continued)
1.
2.
3.
4.
16. Electricity and water inlets on the outside walls of the Trailer shall be weather
proof.
17. Operation and intensive care rooms shall be provided with filters for bacteria and
negative pressures.
18. All trailers operate with hydraulic extension systems and in case such a system
fails for any reason, the work can be manually performed.
19. The trailer structures shall have a warranty for a minimum period of (10) years.
The Air-Conditioning System
1. Either central or separately for each individual trailer. All trailers without
exception must be air-conditioned. The temperature shall be controlled from
within the trailer.
2. The system must have a warranty for a minimum period of (3) years.
3. Spare parts must remain available for a minimum period of (10) years.
Electric Generators:
1. One or more electric generators capable of operating the hospital and its annexes
in full, in addition to another emergency generator. The load shall be
automatically transferred to the emergency generator upon power failure using
ATS system.
2. There must be agent for the equipment in Saudi Arabia.
3. The generator must be the production of internationally recognized companies
known for good industry and endurance of high temperatures.
4. The generators must have a warranty for a minimum period (3) years. Spare parts
must remain available for a minimum period of (10) years.
Medical equipment and furniture:
1. Attached are tables showing the numbers and specifications of medical
equipment and furniture which must be committed to.
2. All medical equipment and systems must be compatible with the mobile trailer.
3. They shall be of good quality known industry.
4. They must have a warranty for a minimum period of (3) years.
5. Spare parts must remain available for a minimum period of (10) years.
ANNEX 2
OPERATION THEATRE
Item
Manufacturer
Qty
Number
Country
1
Ohmeda
Model
Description
7100
Anesthesia Machine complete,
3
U.S.A.
2
including ventilator, as per
specifications
Amico
VR-C2UD-
Suction Regulator, as per
Canada
CMA
specifications
Physio-Control
LP20
Crash Cart, Defibrillator, as per
9
3
6
and ABMSC
U.S.A.
4
specifications
ValleyLab
Force Argon Electrosurgical Unit, as per
U.S.A.
II
specifications
Pedigo
NC100
Mayo-Stand for Surgical
3
5
3
U.S.A.
6
Pedigo
Instruments, as per specifications
P-1020SS
Kick Bucket, as per specifications
6
U.S.A.
ANNEX 2
OPERATION THEATRE
(continued)
Item
Manufacturer
Model
Qty
Number
Country
(USD)
(USD)
Description
7
Light Operation Theatre, as per
Steris
LA500
3
U.S.A.
specifications
(ENGLISH – Surgical Lights)
8
GE
S-5
Physiological Monitoring Unit,
U.S.A.
Anesthesia
Surgical, as per specifications
(ENGLISH – Vital Signs Monitor)
Steris
3085
Operating Table, as per
3
9
3
U.S.A.
10
Alaris
specifications
7130B
Infusion Pump, as per specifications
Infusor
Syringe Pump, as per specifications
1200
Blood Warmer, as per specifications
6
U.S.A.
11
Bard
6
U.S.A.
12
Level 1
6
U.S.A.
ANNEX 2
OPERATION THEATRE
(continued)
Item
Manufacturer
Qty
Number
Country
13
Galaxy
Model
Description
1068
Stool, Anesthetist, as per
3
U.S.A.
14
Galaxy
specifications
1165
Stool, Operating, as per
3
U.S.A.
15
Anesthesia
specifications
(ENGLISH – Doctor’s stool)
Penlon
Laryngoscope Set, Adult/Pediatric
3
Associates
U.S.A.
16
Coulmed
3
w/different blades, as per
specifications
CM106
Table, Instrument as per
U.S.A.
17
specifications
Littmann
4000
Stethoscope for Anesthetist, as
3
U.S.A.
18
per specifications - electronic
ABMSC
ABM-25
Suction Machine Mobile, as per
3
U.S.A.
specifications
ANNEX 2
OPERATION THEATRE
(continued)
Item
Manufacturer
Qty
Number
Country
19
Burton
Model
Description
6230
Lamp, Ultraviolet, as per
3
U.S.A.
20
specifications
Galaxy
1060
Nurse Stool
2540
Counter-top Autoclave
12
U.S.A.
21
Tuttnauer
3
U.S.A.
22
Amico
A2ME20
Medical Gas System
3
ANNEX 2
AMBULANCE UNIT
Item
Manufacturer
Qty
Number
Country
1
Steris
Model
Description
462
Patient Bed, Stretcher, as per
12
U.S.A.
specifications
(ENGLISH – Gurney)
2
Drive
FFPI
Wheel Chair, as per specifications
15FL
Oxygen Flow Meter with
3
U.S.A.
3
Hudson RCI
3
U.S.A.
4
Humidifier, as per specifications
Amico
VR-C2UD-
Suction Regulator, as per
Canada
CMA
specifications
Welch Allyn
62000
Vital Signs Monitor, Wall Mounted,
3
5
3
U.S.A.
6
Physio-Control
as per specifications
LP20
Defibrillator, as per specifications
3
U.S.A.
ANNEX 2
AMBULANCE UNIT
(continued)
Item
Manufacturer
Model
Qty Unit Price
Total Price
Number
Country
(USD)
(USD)
Description
7
Resuscitator, Adult, as per
Hudson RCI
RC101
3
U.S.A.
8
Hudson RCI
specifications
(ENGLISH – Ambu-bag)
RC100
Resuscitator, Pediatric, as per
3
U.S.A.
specifications
(ENGLISH – Ambu-bag)
ANNEX 2
LABORATORY
Item
Manufacturer
Qty
Number
Country
Model
Description
1
Bayer
Advia
Hematology Analyzer, as per
3
U.S.A.
2
Beckman
specifications
CX3
Chemistry Analyzer, as per
3
U.S.A.
3
Centra
specifications
CL
Centrifuge, Bench Top, as per
3
U.S.A.
4
Micromaster
specifications
CK
Microscope Basic, as per
6
U.S.A.
5
Titer
specifications
14260
Shaker, as per specifications
14059
Mixer, as per specifications
12-813
Rocker, as per specifications
3
U.S.A.
6
Fisher
3
U.S.A.
7
Wheaton
3
U.S.A.
ANNEX 2
LABORATORY
(continued)
Item
Manufacturer
Qty
Number
Country
8
Fisher
Model
Description
13-874
Bath, Water, as per specifications
11-690
Incubator, Electronic, as per
3
U.S.A.
9
Fisher
3
U.S.A.
10
Fisher
3
specifications
952
Refrigerator, Low Temp.
U.S.A.
11
Fisher
(Freezer), as per specifications
950
Refrigerator, as per specifications
545
Timer (Electronic), as per
3
U.S.A.
12
Fisher
3
U.S.A.
13
Barnstead
specifications
4-6V
Distillation Unit, as per
3
U.S.A.
specifications
(ENGLISH – Water Purifier)
ANNEX 2
LABORATORY
(continued)
Item
Manufacturer
Qty
Number
Country
14
Fisher Isotemp
Model
Description
13987
Blood Bank Refrigerator, as per
3
U.S.A.
15
Ames
specifications
AM-577
Urine Analyzer, as per
3
U.S.A.
16
Winco
specifications
655
Couch (For Blood Draw), as per
3
U.S.A.
17
Wayne
specifications
(ENGLISH – Recliner Blood
Station)
S-1000
Hot Air Sterilizer, as per
3
U.S.A.
specifications
(ENGLISH – Dry heat
Sterilizer)
ANNEX 2
STERILIZATION UNIT (STERILE SUPPLY)
Item
Manufacturer
Model
Qty Unit Price
Total Price
Number
Country
(USD)
(USD)
Description
1
Sterilizer Unit, Steam, as per
Steris
3013
3
U.S.A.
2
Steris
specifications
3000
Washer, Disinfector, as per
3
U.S.A.
3
Steris
specifications
Caviwave
Cleaner, Ultrasonic, Floor Mounted,
3
U.S.A.
as per specifications
ANNEX 2
PHARMACY
Item
Manufacturer
Qty
Number
Country
1
Hamilton
Model
Description
6920
Cabinet Medicine, as per
3
U.S.A.
2
Hamilton
specifications
8920
Storage Medicine Cabinet, Two
3
U.S.A.
3
Health Care
Door, as per specifications
8222
Cabinet, Narcotic, Double Door,
9
Logistics
U.S.A.
4
Fisher
Wall Mounted, as per specifications
920
Refrigerator, Pharmaceutical, as
3
U.S.A.
5
Kirby Lester
per specifications
KL15df
Counter, Tablet, Electrical
3
U.S.A.
Automatic, Bench Top, as per
specifications
6
Health Care
1893
Bin, Unit Dose Medication,
3
Logistics
U.S.A.
Medium, as per specifications
ANNEX 2
PHARMACY
(continued)
Item
Manufacturer
Qty
Number
Country
7
Health Care
Model
Description
1892
Bin, Unit Dose Medication, Large,
3
Logistics
U.S.A.
8
as per specifications
Health Care
1700
Bin, Unit Dose Medication, Small,
3
Logistics
U.S.A.
as per specifications
ANNEX 2
OPHTHALMOLOGY CLINIC
Item
Manufacturer
Qty
Number
Country
1
patient 3
Topcon
$
U.S.A.
overhead
Model
Description
IS-2500
Eye Examination System with
chair, Ophthalmic Stand with
lamp and complete with slit lamp,
Autokerato-refractomete, Phoroptor
Unit and Autochart Projector, as per
specifications
2
Welch Allyn
18335
Ophthalmoscope, Indirect, as per
3
U.S.A.
specifications
3
Topcon
LM-8/8E
Lensometer with Marking Device, as
3
U.S.A.
4
as
per specifications
Infocus
TLS-266
Lenses, Trial, Complete set in case,
3
U.S.A.
5
per specifications
Ilab
STB-13
Sternest (Stereoposis Test Book or
3
U.S.A.
6
Drawing), as per specifications
Topcon
SS-3
Retino Scope, as per specifications
3
U.S.A.
ANNEX 2
OPHTHALMOLOGY CLINIC
(continued)
Item
Manufacturer
Qty
Number
Country
7
Perkins
Model
Description
P.E.T.
Tonometer, Ophthalmic, as per
3
U.S.A.
8
Capital
specifications
M2001
Binocular Loop, as per specifications
3
U.S.A.
ANNEX 2
DENTAL CLINIC
Item
Manufacturer
Qty
Number
Country
1
ASI
Model
Description
2400E
Dental Chair, Complete, as per
3
U.S.A.
2
Dentsply
3
specifications
Promix
Amalgamator, as per specifications
U.S.A.
3
Triad
2000
Light Curing Unit, as per
3
U.S.A.
4
Dent
specifications
810
Film Processor, Dental, as per
3
U.S.A.
5
Siemans
specifications
DS
Dental X-Ray Unit, as per
3
U.S.A.
6
CPC-Henan
specifications
UDS-L
Dental Scaler Unit, as per
3
U.S.A.
7
MCC Cabinets
specifications
MFB 210SP
Dental Cabinet System with sink,
3
U.S.A.
Item
Manufacturer
Qty
Number
Country
8
Pedigo
with sink
as per specifications
ANNEX 2
DENTAL CLINIC
(continued)
Model
Description
SG-92
Dental Instrument Table, Mobile,
3
U.S.A.
9
as per specifications
Mettler
Cavitator
Ultrasonic Cleaner, as per
U.S.A.
II
specifications
Tuttnauer
EZ10
Autoclave Unit, Dental, as per
3
10
3
U.S.A.
specifications
ANNEX 2
ENT CLINIC
Item
Manufacturer
Qty
Number
Country
1
Reliance
Model
Description
425
ENT Treatment Unit, Complete as
3
U.S.A.
2
Interacoustics
per specifications
Equinox
Audiometer, Clinical, as per
3
U.S.A.
3
Interacoustics
specifications
AT325h
Middle Ear Analyzer, as per
3
U.S.A.
specifications
ANNEX 2
X-RAY
Item
Manufacturer
Model
Description
Qty
Number
Country
1
GE
MPI
X-Ray Unit, General, as per
U.S.A.
Precision
System
specifications
GE
RPN1700
X-Ray Film Processor, Bench Top,
3
2
3
U.S.A.
3
Lumimed
as per specifications
LD12A
X-Ray Film Viewer, Double, as
3
U.S.A.
4
AXS
per specifications
PA-ha2424
Apron Patient Protective, as per
24
U.S.A.
5
specifications
Kodak
X-Omatic ID X-Omatic Identification Camera,
U.S.A.
Camera #4
Digital, as per specification
AXS
DR-FB1417
Film Bin for X-Ray
3
6
3
U.S.A.
7
Kodak
X-Omat RP
X-Ray Film
3 set
U.S.A.
ANNEX 2
PRIMARY CARE CLINIC
Item
Manufacturer
Model
Qty
Number
Country
(USD)
(USD)
Description
1
Examination Table, as per
Midmark
106
12
U.S.A.
2
GE Healthcare
specifications
S5 Compact
Vital Signs Monitor, as per
18
U.S.A.
3
specifications
Amico
VR-C3U2-
Suction Regulator, as per
Canada
F2A
specifications
Welch Allyn
11735
OTO/Ophthalmoscope, as per
9
4
12
U.S.A.
5
Alaris
specifications
Tri-site
Thermometer Electronic, as per
9
U.S.A.
6
Hemocure
specifications
HC-1
Glucometer, as per specifications
5002
Scale Standing Digital, as per
9
U.S.A.
7
Scaletronics
9
U.S.A.
Item
Manufacturer
Qty
specifications
ANNEX 2
PRIMARY CARE CLINIC
(continued)
Model
Description
Number
Country
8
Gomco
401
Suction, Portable, as per
9
U.S.A.
9
Ritter
specifications
151
Examination Light, as per
12
U.S.A.
10
MacIntosh &
specifications
80613
Laryngoscope Set, as per
12
Miller
U.S.A.
11
American
specifications
AMS01
X-Ray Viewer, Single, as per
12
Medical Sales
U.S.A.
12
Hudson RCOI
specifications
2042
Oxygen Flow Meter with
12
U.S.A.
13
Omron
Humidifier, as per specifications
11-675DNL
Sphygmomanometer, Wall
12
U.S.A.
Mounted, as per specifications
ANNEX 2
IN-PATIENT UNIT
Item
Manufacturer
Qty
Number
Country
1
Hill-Rom
Model
Description
Century
Patient Bed, Electric, as per
60
U.S.A.
2
GE
specifications
S5 Compact
Vital Signs Monitor with Trolley,
42
U.S.A.
3
Alaris
42
as per specifications
7130B
Infusion Pump, as per
U.S.A.
4
specifications
Hudson RCI
15FL
Oxygen Flow Meter with
72
Humidifier, as per specifications
5
Amico
VR-C2UD-
Suction Regulator, as per
60
Canada
Item
Number
CMA
specifications
ANNEX 2
MOBILE MODULAR TRAILERS
Manufacturer
Country
Model
Description
Units complete with modules listed for 3 medical centers complete
1
2
3
4
5
6
Item
ABMSC
Included
U.S.A.
36
ABM-MMU- Emergency / Triage Module
ET01
ABMSC
Included
U.S.A.
ABM-MMU- Surgical / Operating Module
OR01
ABMSC
Included
U.S.A.
ABM-MMU- Radiology / X-Ray Module
RAD01
ABMSC
Included
U.S.A.
ABM-MMU- Maternity / GYN Module
MAT01
ABMSC
Included
U.S.A.
ABMSC
Included
U.S.A.
Qty
ABM-MMU- Central Procssing / Sterilization
CS01
Module
ABM-MMU- Laboratory / Pathology
LP01
Module
ANNEX 2
MOBILE MODULAR TRAILERS
(continued)
Manufacturer
Model
Description
Qty
Number
7
8
9
10
11
12
13
Country
ABMSC
Included
U.S.A.
ABM-MMU- Primary Patient Care
GPC01
ABMSC
Included
U.S.A.
ABM-MMU- Pharmacy Module
PH01
ABMSC
Included
U.S.A.
ABM-MMU- Opthalmology Module
OP01
ABMSC
Included
U.S.A.
ABM-MMU- ENT Module
ENT01
ABMSC
Included
U.S.A.
ABM-MMU- Dental Care Module
DC01
ABMSC
Included
U.S.A.
ABMSC
Included
U.S.A.
Module
ABM-MMU- General Utility Module
GU01
ABM-MMU- Staff Care Module
SCM01
ANNEX 2
MOBILE MODULAR TRAILERS
(continued)
Item
Number
Manufacturer
Country
Model
Description
Tents
ABMSC
U.S.A.
Item
Number
Manufacturer
Country
Model
Description
Qty
1
MQ Power
U.S.A.
MOP150IV
Generator: 150KVA
Fuel: Diesel tank.
12
ABM-MMU- Multi-Purpose Tents
APT01
ANNEX 2
EMERGENCY GENERATOR
Qty
12
Trailer: Air cooled.
Electrical Panel for
emergency power.
Variable voltage on demand.
Heavy duty radiator and
cooling system.
Announciator panel.
2
MQ Power
GTK
Generator Tool Kit
3
3
Freightliner/
Mercedes
U.S.A.
4000
Fuel tanker with truck
3
Annex (2-A)
Additional Equipment Required
Item
Manufacturer
Qty
Number
Country
Surgical
Storz
3
Equipment- U.S.A.
Specialty
Storz
3
U.S.A.
Storz
3
U.S.A.
Storz
12
U.S.A.
Storz
6
U.S.A.
Storz
3
U.S.A.
OEC
3
U.S.A.
Leica
3
U.S.A.
Model
Description
2222
Endoscopic tower – complete
2222-G
GYN tower – complete
2222-A
Arthroscopy tower – complete
11272
Endoscope
2600
GYN scope
28300
Arthroscope
9800C
“C” Arm – complete
M525-OH
Surgery microscope
Leica
M525MC
ENT microscope
U.S.A.
Leica
M820
Eye microscope
3
3
U.S.A.
Annex (2-A)
Additional Equipment Required
(continued)
Item
Qty
Number
Manufacturer
U
Country
Model
Imaging
IS8000
Description
“C” arm table
3
U.S.A.
ICU
Hill-Rom
Total Care
Patient bed
U.S.A.
GE
RT
DASH-ICU
Patient ICU monitor
U.S.A.
GE
DASH-
Central station
U.S.A.
GE
Central
DASH-
Telemetry
U.S.A.
Nubenco
Telem
NestoVent 7 Adult/pediatric ventilator
U.S.A.
Phillips
Pagewriter
EKG machine
U.S.A.
Bard
Touch
Infusor
Syringe pump
U.S.A.
Alaris
7130B
Infusion pump
12
12
3
12
6
3
15
36
U.S.A.
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Kitchen
3
Unit
AFS
Model
Description
436D6
Oven
U.S.A.
Hobart
3
U.S.A.
AFS
T9-3-54-
Sink
U.S.A.
Hobart
18RL-3
LX1H3
Dishwasher
81277
Refrigerator – walk-in
WB3610028 Grill
3
3
U.S.A.
Ameri/Kooler
3
U.S.A.
AFS
3
U.S.A.
Hatco
3
U.S.A.
AFS
3
U.S.A.
Carlisle/ABC
3
U.S.A.
Victoria
3
U.S.A.
KAG-3012-2 Prep station
HDW-3
Warming station
ABM-KU
Utensils
A60200
Pots & pans
BACR-02
Salad bar area
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
Amana
3
U.S.A.
BrewMatic
3
U.S.A.
Randell
3
U.S.A
Crescor
3
U.S.A.
Vulcan
3
U.S.A
Carter/Hoffman
3
U.S.A.
Gormet
3
U.S.A.
Scottsman
3
U.S.A.
ATS
3
U.S.A.
AMH20D
Microwave / Convection
10325200
Coffee maker station
9045K-7
Food cart - refrigerated
PWS-1834-C Mobile Heated Cabinet
1GR65
Fryer
PRF850
Mobile refrigerated cabinet
5003531
Drink dispenser
NME954AS
Ice machine
SKU-548TT Table & chairs
Annex (2-A)
Additional Equipment Required
(continued)
Item
Qty
Number
Manufacturer
Unit Price
Country
Hospital
Office Furniture
3 sets
Furniture
U.S.A.
Medline
3 sets
U.S.A.
Hon
3 sets
U.S.A.
Medline
3 sets
Model
Total Price
Description
OFG-LD30
Desk
MDR311204 Patient charts
174-665
Filing cabinets
MDR4307
Overbed tables
U.S.A
Medline
MDR811305
Hewlett Packard
3 sets
U.S.A.
Texas Instruments
3 sets
U.S.A
ABMSC
3 sets
U.S.A.
Diamond Drapery
3 sets
U.S.A.
Hewlett Packard
3 sets
U.S.A.
Chairs
ABM-WO
3 sets
Computers – System complete
BA-20
Calculators
Misc
Office supplies
ABM-PT01
Patient curtains
1040
Fax machine
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Canon
3 sets
U.S.A.
ABBA Technology
3 sets
U.S.A.
Medline
3 sets
U.S.A.
Medline
3 set
U.S.A
Medline
3 sets
Littman
Model
Description
MF6550
Copy machine
ABT7000
Phone / Intercom / Security & Data
MDR10450
system
Staff sleeping bed or cot and
MDR90WH
accessories
Waiting room chairs
MDR640
Waiting room tables
MDJ9290
Stethoscopes
H1
Ambulance vehicle:
3 sets
U.S.A.
Ambulance
3
Hummer
U.S.A.
Labor &
6
Delivery
With diesel fuel – complete
Special cooled engine
V min 6 cylinders
Hill-Rom
Affinity
U.S.A.
4 Plus
Labor & delivery bed
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Ohmeda
Model
Description
7100
Anesthesia machine
LP20
Crash cart
462
Gurney
250CS
Fetal monitor
Panda
Baby warmer
MENFP3B
Fetal Doppler
Careplus 12
Incubator
EZ10VP
Autoclave
Sonoline
GYN ultrasound
Affinity
Procedure room furniture
3
6
U.S.A.
Physio-Control/
3
U.S.A.
Steris
6
U.S.A.
Cormetrics
12
U.S.A.
GE
9
U.S.A.
Medsonics
$
U.S.A.
GE
3
U.S.A.
Tuttnauer
3
U.S.A.
Siemens
3
$
U.S.A.
Hill-Rom
3 sets
U.S.A.
Series
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Nebenco
3
U.S.A.
Steris
3
U.S.A.
ValleyLab
3
U.S.A.
ABMSC
6 sets
U.S.A.
Steris
3
U.S.A.
GE
3
U.S.A
GE
3
U.S.A.
ABMSC
3
U.S.A
Emergency
3
Room
Ritter
Model
Description
NestoVent
Neonatal ventilator
7N
3085
O.R. Table
Force FX
Electrosurgical unit
Misc
Labor & delivery furniture
Harmoney
O.R. light
S5
Patient surgery monitor
Anesthesia
S5 Compact
Patient labor & delivery monitor
Misc
Miscellaneous procedure supplies
109
Treatment table
U.S.A.
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
Winco
630
Recliner
9
U.S.A.
American
3
Orthopaedic
U.S.A.
Physio-Control /
3
ABMSC
U.S.A.
ABMSC
3
U.S.A.
GE
12
U.S.A.
Phillips
3
U.S.A.
Scottsman
3
U.S.A.
Steris
3
U.S.A.
Amico
3
Canada
0295-200WC Cast Cart
ABM/LP20
Crash Cart
Misc
Emergency supplies
S5 Compact
Patient monitor
Pagewriter
EKG machine
Touch
MDT5N25
Ice machine
AWC-1
Blanket warmer
Amico
Medical gas
System
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Miscellaneous
Equipment Freightliner/
6
Mercedes
U.S.A
Best Products
3
Model
Description
4001
Water tanker
37B3
Janitor equipment
U.S.A.
Sanitaire
3
U.S.A.
Janlink
3
U.S.A.
Profex
3 sets
U.S.A.
Coulmed
3 sets
U.S.A.
Hospital Systems
3 sets
U.S.A.
Unimax
3 sets
U.S.A.
Steris
3
U.S.A.
6080
Vacuum
180
Buffers
HS50
Hospital hampers
CM510
IV stand
2000
Elapse timer
FTUAIA
Laundry washer & dryer
UTF75
AWC-1
Blanket warmer
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Bair Hugger
3
U.S.A.
Scotsman
3
U.S.A.
Freightliner
3
U.S.A.
Freightliner
3
U.S.A.
Amico
3
Canada
Model
Description
1000
Patient warmer
NME954AS
Ice machine
4901
Hazardous waste tanker
4902
Trash truck
SCSL400
Medical vacuum system
GE
3
U.S.A.
ABMS
3 syst
U.S.A.
Midmark
VIVA-7
Ultrasound ECG, urology
1000
Nurse call / code blue system
AVB20R
Wet Vacuum
3
U.S.A.
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Instruments Millennium
6
U.S.A.
Milleinnum
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
Model
Description
ABM-AGN- Abdominal gynecological set
012
ABM-BS-
Basic set
001
ABM-BES-
Basic ear set
006
ABM-BEYS- Basic eye set
002
ABM-BNS-
Basic nasal set
003
ABM-BOT-
Basic ortho set
001
ABM-BVT
Basic vaginal instrument
01A
ABM-SCT-
Cataract set
001
ABM-NCT-
Chest tube insertion tray
007
ABM-BCS-
Circumcision set
U.S.A.
001
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Item
Description
ABM-GYDC- D & C set
002
ABM-BEYM- Eye muscle tray 1
004
ABM-GSGD- Gall bladder and common duct set
003
ABM-BSHS- Hand set
007
ABM-BSHT- Hemerrhoid tray
002
ABM-BSHS- Hernia set
001
ABM-BSID- I & D set
004
ABM-BSLS- Laparoscopy set
002
ABM-PTL-
Large plastic tray
002
ABM-MNS- Major nasal set
003
Annex (2-A)
Additional Equipment Required
(continued)
Manufacturer
Qty
Model
Model
Description
Number
Country
Millennium
6
U.S.A.
Millennium
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
ABM-MNNS- Minor nasal set
002
ABM-MSS002
ABM-MSS-
Minor tray
001
ABM-PSS-
Pediatric set
001
ABM-PTS-
Small plastic tray
001
ABM-SPKW- Steinman Pin & Kerschner Wire Set
001
ABM-BSRM- Radical mastectomy set
001
ABM-BSRS- Rectal set
002
ABM-BNEI- Sinus endoscopy instruments
004
ABM-NSSG- Skin graft set
002
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Qty
Number
Country
Millennium
6
U.S.A.
Millennium
6
Minor surgery set
Model
Description
ABM-BSOS- Supplemental Ortho instruments
007
ABM-BSTA- T & A set
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
6
U.S.A.
Millennium
002
ABM-BSTS- Thyroidectomy set
003
ABM-BUD- Urethral dilation set
001
ABM-BSTS
Tracheotomy set
002
ABM-VTL-
Vaginal tubal ligation set
003
ABM-MIN
Minimally invasive neuro
U.S.A.
Millennium
001
ABM-ISC
instrument tray
Instrument sterilization
U.S.A.
000
Containers
N/A
Consumables
6
222
Hospital
McKesson
3 sets
Supplies
U.S.A.
Annex (2-A)
Additional Equipment Required
(continued)
Item
Manufacturer
Model
Description
Qty
Number
Country
McKesson
3 sets $
U.S.A.
AKRO
3 sets $
U.S.A.
N/A
Disposables
AKM30210- Storage Container for
70
miscellaneous supplies
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
Anesthesia Machine Complete, Including Ventilator:
• Input cylinder, three Gas Manifold, fitting pin indexed
• Pipeline input connection for Oxygen, Nitrous Oxide, Air (inlet fitting British
Standard)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Provided cylinders (Oxygen, Nitrous Oxide, Air)
Precision Calibrated Flow meters of Oxygen, Medical Compressed Air And
Nitrous Oxide
Flowmeters: Oxygen two tubes- ranges 0.05 to 0.95 L/min and 1.0 to 15.0 L/min,
Nitrous oxide two tubes- ranges 0.05 to 0.95 L/min and 1.0 to 10 L/min and Air
two tubes 0 to 0.95 and to 1 to 15 L/min
System with three Vaporizer
The system can not turn on more than one Vaporizer at a time and Vaporizer and
manifold prevents gas flow through all the vaporizer that are off
Built in Battery in Ventilator, internal rechargeable sealed lead acid
Approximately 30 minutes of operation provided by battery
Complete power failure or sudden gas failure (or low pressure gas) should
indicate visually and audibly
Ventilator to monitor inspiratory, expiration volume and airway pressure
Ventilator screen Height x Width: 7.6 x 15.2 cm
Ventilator operating modes: Volume controlled and pressure limited and pressure
controlled
Ventilator performance ranges: Tidal volume 20 to 1500 ml (Volume control
mode) with incremental setting, Minute volume range 0 to 99.9 L/min, and
pressure inspired range 12 to 60 cm H2O (increments of 1 cm H2O)
Positive End Expiratory Pressure (PEEP) integrated and electronically controlled,
range: off, 4 to 30 cm H2O (increment of 1 cm H2O)
Alarm sittings for Tidal volume, Minute volume, inspired oxygen for Low and
High. Also to be warm setting for Apnea, Low air way pressure, high pressure
Provided Autoclavable sensor
On Castors size diameter: 12.5 cm and brakes: single foot lever locks and unlocks
two front castors
Spare Socket box for other equipment
With Two Shelve and folding side shelf for accessories
Leakage current less than 500 micro ampere
Power Supply: 230Volts +/- 20%, 6A, 60Hz
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
Suction Regulator:
• Included regulator, jars, probe (inlet fitting British standard), rail mounted,
and hose.
• With overflow safety trap
• Internally well designed with the increments in cmH20 & kPa to give accurate
vacuum by precision regulating diaphragm
• With two scales -mmHg and -kPa
• With three modes Off, On and Max.
• With the feature of positive pressure relief valve vents accidental positive
pressure away from patient and system
• Two modes high continuous Gauge 0-100KPa
• Flow rate 0-80 1/min
Crash Cart Defibrillator:
• Defibrillator with monitor
• Included Cart
• Enables to monitor ECG (3&Five leads) and Pulse oximetry
• Equipped with ADAPTIV for AED
• Capability of manual operation up to 360 joules with synchronous cardio version
and pacing
• ECG, pulse and saturation oxygen to be displayed
• Enables to configure the device setting
• Enables to access records of previous patient for review, transmission, printing,
editing or deletion
• Built in battery, minimum capacity Defibrillation (360 Joules)# 90 and
monitoring of ECG & SpO2# 2hrs continuous
• Low battery indication: Visual and Audio
• Resolution Color LCD
• Waveform display sweep speed 2Smmlsec for ECG
• Enable to give print our complete report including an introduction with patient
information and critical care event
• ECG size 4,3,2.5,1.5,0.5,0.25 cm/mV
• Heart rate display 20 to 350 beats per minute digital display with accuracy of +/3 digits, Saturation of oxygen range 1 to 100%, Accuracy for 70 to 100% shall be
+/- 2 digits
• Printer paper size: 50mm with speed of continuous ECG 25 mm/sec with +/5%
• Energy delivery accuracy +/- 1 Joule
•
•
•
•
Manual Energy Selection: 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 40, 50, 70, 100, 125,
150, 175, 200, 225, 250, 275, 300, 325 & 360 Joules or configurable joule
sequence: 100 to 200, 100 to 300 and 100 to 360
Charge time for 200 Joules less than four seconds
Charge time for 360 Joules less than seven seconds
Power supply: 220 VAC, 50Hz or 60Hz
Electrosurgical Unit:
• Microprocessor controlled
• Mono-polar Auto cut
• Endo cut
• Soft Coagulation
• Argon-plasma cut
• Forced coagulation cut
• Bio-polar coagulation
• Included all the accessories to implement the above functions
• Automatically perfect cut. fixed-reproducible cut quality with minimum necrosis
• No Carbonization, Precisely Controlled Coagulation cutting Monopolar-cut
• Included Table on four castor, of which two lockable
• Monopolar cut with automatic voltage control
ENDOCUT
• With automatic control
• HF power adjustment: with up/down increment keys
• Form of HF voltage: Sine wave
• Nominal frequency of HF Voltage: 350Hz
• Constancy of coagulation effects: Automatic regulated
• Nominal HF output: 200 watts at 5000hrns
COAGULATION
• HF power adjustment: with up/down increment keys
Monopolar Soft Coagulation
• Form of HF current: Sine wave
• Nominal frequency of HF Voltage: 350KHz
• Nominal HF output: 120watts at 200 Ohms
Monopolar Forced Coagulation
• Form of HF current: Pulse modulated
• Nominal frequency of HF Voltage: 1MHz
• Nominal HF output: 120watts at 500 Ohms
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
Monopolar Spray Coagulation
• Form of HF current: Pulse modulated
• Nominal frequency of HF Voltage: 1MHz
• Nominal HF output: 120watts at 500 Ohms
Bipolar Coagulation
• Form of HF current: Sine wave
• Nominal frequency of HF Current: 350KHz
• Nominal HF output: 120watts at 125 Ohms
• Start of coagulation: By foot pedal or Auto start
Safety Precautions
• Software check of output error
• Software check of Activation time
• Neutral Electrode Monitoring
• Neutral Electrode Switching Self
Check
• Error Display
• Power Supply: 220V AC, 50Hz or 60 Hz
Mayo-Stand for Surgical Instruments:
• Instrument Serving table
• With Foot operated pump
• Height Adjustment from 950 to 1350 mm by means of foot bar 18/10 S/S tabletop
70O x 500mm
• With raised edges
• Support column and frame in 18/10 S/S
• Pedestal claded in S/S
• Plastic Double castors diam 75mm Antistatic, rust proof
• Nominal capacity 50 kg
Kick Bucket:
• Removable 12 liters bucket in 18/10 stainless steel
•
•
•
•
18/10 Stainless Steel frame with profiled plastic wrap around bumper
Plastic double castors diameter 50mm, Antistatic and rust proof
Frame height 230 mm
With Bucket lid in 18/10 Stainless Steel
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
Light Operation Theatre:
• Ceiling mounted
• With optimum ceiling combination three Arms
• Two arms for light and the other arm for monitor
• Illumination Combination: 80.000 1x + 140,000 1x
• Fully rotate-able
• Infrared filtration: IRC bulb + Reflector
• Manual adjustment
• Neutral white light, true to color and cool
• Two-step interference filter for increased heat filters
• Electronic reserve lamp switch over when the main light source is down
Integrated On/Off switch
• Sterilizable hand grips
• Fully rotate-ability around the vertical axis and precision positioning in any
desired position
• Light field diameter at 1m distance 17cm
• Working distance 70 to 130cm
• Depth of working are with homogenous light 60cm
• Color temp: 4.3K Kelvin
• Temperature increased at Surgeon's head 2 centigrade
• Power supply: 220V AC, 50/60Hz
Physiological Monitoring Unit, Surgical:
• Specially designed for use in Operation Theatre
• Parameters included ECG/Respiration, Invasive Blood Pressure, Non-Invasive
Blood Pressure, CO2, Temperature (2), SpO2, Anesthesia gas, Pulse rate
• Touch Screen LCD Display 15"
• 8 channel monitoring system in color
• User-defined start up configurations
• Automatic storage of patient data and module settings for transport purposes
• 12 lead ECG with only five electrodes
• Alarm escalation in life-threatening situations
• Enables to install Twelve (12) modules at a time
• Enables to change or another module to slot in without any interruption in
operation
• Patient Electrode leakage current less than 10uA
• Built in Battery operating time min. 4hrs (Internal Battery)
• Power supply 110 to 220Vac. 50/60Hz
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
Operating Table:
• Electro-hydro adjustment by means of remote control
• Also enables to do by manual positioning by pump lever
• With remote control, one touch adjustment of table movement
• Activating key, against accidental table movement
• O-position key automatically returns the table top
• By remote control to three positions i.e. High/Low, Lateral,
Trendelenburg/Reverse Trendelenburg
• Same three positions by hydraulic foot pump independently
• With the reverse mode key to shifting table functions over to reverse mode when
the patient has been positioned in inverted way
• OR table integrated with body/kidney elevator and manual longitudinal
displacement of table top by up to max. 250mm
• Overall length w/o head and leg sections 1140mm
• Overall length w/o head rest, with head and leg sections 2130mm
• Width 590mm
• Height adjustment 720 to 1080 mm
• Trendelenburg 30 degree
• Reverse Trendelenburg 30 degree
• Lateral adjustment (L/R) +/- 20degree
• Back section +70degrcel-50degree
• Leg Plate(s) +20degree/-90degree
• Nominal capacity 185Kg
• Battery operated
• Included rechargeable batteries. External battery charger with mains cable
• Power supply: 220V AC, 50/60Hz
• Accessories included: Head rest (double adjustment). Divided leg section (two
pieces), leg plate (one piece), arm rest, body restraint strap, leg restraint,
Anaesthetic frame, Wristlet, infusion rod, Leg support, Attachment Clamp (swivel
type), pair of shoulder support
• Rack for accessories: Square-section tubular steel frame with 5 rails for
attachment of accessories and 1 basket, stainless steel, antistatic castors, overall
dimension: H x W x D = 1430 x 630 x 580
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
Infusion Pump:
• The volumetric infusion pump for routine tasks and intensive care medicine for
use in all wards
• Microprocessor controlled
• Leakage current should be less than 10 micro ampere
• Delivery range 1-999 ml/hr
•
•
•
•
•
•
•
•
•
•
•
Smallest entry step 1ml/hr or 0.1ml/hr in a range of 1.0-999m1
Delivery precision +/- 5%
Delivery volume pre-setting up to 999.9 ml
Function spectrum/Safety system Stand by, chug selection, cc interface operation,
pressure limit selection, deactivation of drop control, display of battery capacity,
data clock.
Permanent visualization of Delivery rate, current volume, pressure limit, battery
or main driven, mains control, running control
Info-query Infusion status. current and total volume remaining volume
Mains/Battery operation
Voltage 220V, 60Hz
External low Voltage 12
Battery type NiCd, rechargeable
Battery operated time approx: 3.5 hrs
Syringe Pump:
• Setting for major syringe brands that is 10ml, 20ml, 30ml, and 50ml available in
the market
• 0.1 to 200ml/hr with 10ml syringe. 0.1 to 300ml/hr with 20ml, 30ml or 50ml
syringe
• Drive Accuracy +/- 1 %
• Volume Infused display 0.1 to 999.9ml
• With Alarm lamp and Audible alarm in case of small remains or having the
problem not infusing
• With the rechargeable battery, battery time minimum 4hrs
• Power supply 240 Volts 60Hz.
Blood Warmer:
• Warmer for Blood and solution
• Enables to use for IV and Irrigation
• Flow range ml/min adjustable
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
•
•
•
•
•
•
•
Heat Exchanger technology and set-point temperature Dry heat and 38-40
respectively
LED Display, temperature range 30 to 42 centigrade with the increment of 0.5
centigrade
Primary temperature control by Microprocessor
High temperature cut off at 41 Centigrade
With High temperature a1arm shall be audible, visual and alarm test
With the IV pole attachment
Power Supply 220 Volts, 50/60Hz
Stool, Anesthetist:
• Specially designed to use in operation theatre
• Mobile Swivel
• Construction of stainless steel 18/10
• On five castors
•
•
Height adjustable 600 to 700 mm high
Standing space 600mm diameter
Stool, Operating:
• Specially designed to use in operation theatre
• Mobile Swivel
• With round Seat & Back
• Construction of stainless steel 18/1 0
• Height adjustable 600 to 700 mm high
• Standing space 600mm diameter
Laryngoscope Set, Adult/Pediatric w/different blades:
• Size Standard
• Blade type Macintosh in quantity number three (3) Large, adult and child with
Lamp installed
• Fitting Blade: hook on fitting
• Tip adjustable on the blade to provide the Clinician with greater flexibility,
especially in cases of difficult incubating
• Uses four different angles between the blade and handle i.e. 90 degree, 45 degree
180 degree and 135 degree (Standard)
• With four locked position light remains illuminated during changing from one
position to another
• Blade is McCoy type
• Blade hook on fitting
ANNEX 2—SPECIFICATIONS
OPERATION THEATRE
(continued)
•
•
Tip adjustable on the blade to provide the Clinician with greater flexibility,
especially in cases of difficult incubation
Complete Set provided in Zippered Case
Table, Instrument:
• 18/10 Stainless steel frame, 18/10 S/S table top 600 x 400mm
• Non rotate able
• Height adjustable 900 to l,320mm
• Plastic double castors diam, 50mm, Antistatic, Rustproof
• Nominal capacity 12 Kg
Stethoscope for Anesthetist:
• Recommended for use of Anesthetist
• Lithman (Only)
• Manufactured in USA or UK
Suction Machine Mobile:
• Mobile, on four castors antistatic, two of which lockable
• With the overflow safety and bacterial filter
• The air flow rate of the pump can be controlled by integrated regulating valve and
vacuum display
• With two collection jars, three (3) liters, plastic, sterilize-able
•
•
•
•
•
All parts which may come into contact with secretion for example collection jar
and hoses shall be sterilize-able
Suction hose: #6mm, length 1.30m and #10mm, length 2meter
Size: H x W x D # 300 x 330 x 200 mm
Operating time greater than 240 minutes without switch off at nominal voltage
Power supply: 220V AC, 60Hz, 75W
Lamp, Ultraviolet:
• For Air Sterilizer
• Wall mounted
• Material stainless steel
• UV Radiation Intensity: total watts #72, micro W/sq cm at 1m # 20
• Slim-line tube, two tubes
• Expected life hrs. 7500
• Power supply: 220V AC, 50/60Hz
ANNEX 2—SPECIFICATIONS
AMBULANCE UNIT
Patient Bed:
• Provision for oxygen tank, IV pole and storage utility
• Casters diameter: 150mm with central locking system
• Provision for X-ray cassette. full length X-ray procedure can be carried out
• Protective bumpers
• Bed frame, steel frame work
• Finishing, scratch and chip resistant epoxy coating
• Safety friction lock tilting
• Hydraulic foot pedal controlled Hi-La position
• Collapsible side rail
• Mattress. water resistant
Wheel Chair:
• Folding wheel chair, detachable desk armrests, swinging detachable elevating
adjustable height leg rests. safety belt
• Seat width 38cm and 43cm
Oxygen Flow Meter with Humidifier:
• Direct fitted to the Outlet (BOC British Standard), included with the Humidifier.
• Nickel-plated brass base and body
• Clear shroud
• Expanded lower scale 0-5Lpm
Suction Regulator:
• Included regulator, jars, probe (inlet fitting British standard), rail mounted, and
hose.
• With overflow safety trap
• Internally well designed with the increments in cmH2O & kPa to give accurate
vacuum by precision regulating diaphragm
• With two scales -mmHg and -kPa
•
•
•
•
With three modes Off, On and Max.
With the feature of positive pressure relief valve vents accidental positive
pressure away from patient and system
Two modes high continuous Gauge 0-100KPa
Flow rate 0-80 1/min
Vital Signs Monitor, Wall Mounted:
• Parameters include ECG, NIBP, SpO2, Pulse rate and Temperature
• Large LED Display easily able to seen 3 meter distance
ANNEX 2—SPECIFICATIONS
AMBULANCE UNIT
(continued)
•
•
•
•
•
•
•
•
•
•
•
Color Coding clearly presents parameters data second by second
Built in Printer
Internal rechargeable battery operating life Minimum two hour
Technique Automatic Oscillometric
Range 0-255 mmHg Accuracy +/- 2 mmHg
Cuff inflation 3 to 20 seconds
With Alarm for Systolic and Diastolic
Pulse Oximeter Range 0-90 %, Resolution 1 %
Accuracy +/- 2%
Heart rate Range 0-250 bpm, Resolution 1 bpm. Accuracy +/- 1 bpm
Power Supply 220 Volt 60 Hz
Defibrillator:
• Automatic defibrillator with digital monitor
• Equipped with adaptive for AED
• Energy Select: 2 to 360 Joules or user's configurable sequence
• Charge time to 360 joules in less than 10 seconds
• Distinct tone for Alert. charging, shock, Ready
• Defibrillator pads, solid gel type, self-adhesive disposable
• ECG Analysis available for monitoring and pulse oximetry
• Built in Battery: Rechargeable Nickel-Cadmium battery pack with capacity of 50
energy discharges or 3.5 hrs monitoring
• Digital chart recorder and built in printer
• Power supply 220V 60Hz
Resuscitator, Adult:
• Silicone Resuscitator w/ exceptional bag re-expansion and superior feel for lung
compliance
• Fully autoclavable bag and Adult face mask (2 sets)
• Include with Oxygen Reservoir bag (2600ml), Silicone extension tube and
complete with patient valve
Resuscitator, Pediatric:
• Silicone Resuscitator w/ exceptional bag re-expansion and superior feel for lung
compliance
• Fully autoclavable bag and Adult face mask (2 sets)
•
Include with Oxygen Reservoir bag (2600ml), Silicone extension tube and
complete with patient valve
ANNEX 2—SPECIFICATIONS
LABORATORY
Hematology Analyzer:
• Performs automated blood counts for aspirating blood, dilution, measuring,
calculations, print out and computer transfer
• Advance data management
• With two printer (Graphic and Ticket)
• Parameters shows on 14 inch screen
• Parameters WBC, LYM%, LYM#, MON#, GRA#, GRA%, RBC%, HGB, HCT,
MCV, MCM, MCHC, RDW, PLT, MPV, PDW, PCT
• Histograms WBC, RBC, PLT (Three distribution curves)
• Power Supply 11 0V/220 Volts 50Hz or 60Hz
Chemistry Analyzer:
• Fully Automatic with a minimum operator involvement, fast and accurate results
• Dry Slide Technology
• Capable of performs over 35 tests including basic chemistries, Electrolyte,
enzymes, esoterics and full lipid profile. (pH, H, pCo2, pO2, Na, K, Ca, Cl, Hct
etc.)
• Analyze time 40 to 60 seconds
• Individual packaged test slide
• Sample type Whole blood. If plasma/serum required must be provided Centrifuge
with machine and necessary requirement
• Sample 10 micro liters of serum or plasma
• Special chemistry test and Electrolytes separate modules connected to the Main
System Analyzer
• Power Supply: 110V/220 V AC 50-60 Hz
Centrifuge, Bench Top:
• Compact Unit, Versatile
• Enable to use as Micro-Hematocrit Cyto centrifuge, included accessories
• Enable to use standard tube sizes
• With sixty minutes timer
• Display for time and speed
• Up to 12000 rpm enables to change by steps
• Automatically shut off the unit if sample load is not properly balanced
• Auto-dynamic Electric Braking
• All metal cabinet
• Exterior backed enamel finish
• Guard bowl Stainless Steel
• Power Supply: 220V AC, 50Hz or 60Hz
ANNEX 2—SPECIFICATIONS
LABORATORY
(continued)
Microscope Basic:
• Combine advanced optics with the operating simplicity of a standard laboratory
Microscope
• Long Ann design
• Well-Balanced Arm Perfect Positioning
• High-Intensity Halogen illumination
• Well-Balanced Arm Perfect Positioning
• Objective Lens f=200mm
• Variable angle binocular tubes
• 12.5x eyepieces with a scale
• Included Lenses and necessary accessories
• Flatness of field, color correction and image quality superior to those obtainable
with conventional achromatic system
• With the four objective
• With the capability variations to accommodate a wide a wide range (to advanced
bacteriology)
• Rotate able Body: Inclined Monocular
• Automatic Linkage of illumination And Zoom Control
• Stage Plain with slide clips
• Focusable Revolving Nose Piece Double
• Condenser: in stage condenser and Disc Diaphragm
• In base illuminator with transformer
• Power supply 220 Volts 50/60 Hz
Shaker:
• Double Deck, removable trays which hold up to forty six 10 ml Vacutainers
• Complete Silent
• Accepts tubes of any diameter up to 6"
• Shaking Speed from 22 to 70 reversible per minute
• Trays may be added or removed during operation
Mixer:
•
•
•
•
Continuous gentle mixing in hematology, chemistry research for blood samples
Can hold serum bottles or other vessels, separately or collectively
Top plate is robber dimple
Power supply 220 Volts 50/60 Hz
ANNEX 2—SPECIFICATIONS
LABORATORY
(continued)
Rocker:
• Producing uniform, homogeneous test-tube specimens in hematology. chemistry
and Urology
• 16-tube capacity
• Washable tube pad
• 24 rocking cycles per minutes
• Speed: 24 cycles per minutes
• Rocking platform can hold 16 standard test tubs up to 20 x 150 nun
•
•
•
The friction-grip. silicon robber cushion holds test tubes firmly in place and
prevents bumping
Capped test tubes can be easily loaded and 'unloaded with out turning the mixer
off
Power supply 220 Volts 50/60 Hz
Bath, Water:
• Bath Capacity 2.5 liter to 5 liters
• Temperature Range 40 to 260 Centigrade
• Bathe Uniformity +/- 0.01 Centigrade
• Microprocessor controlled, Digital
• LED, display
• Adjustable High limit control 20 to 320 Centigrade
• Press pumps max. Flow 20 liters/min
• Suction Max. Flow 14liters/min
• Enable to connect for programmer or Remote Control
• Enable to connect Remote Sensor
• Enable to connect recorder or visual/audio alarm
• Power Supply 220V AC, 50Hz or 60 Hz
Incubator, Electronic:
• Precision designed for smaller work load
• Temperature range +5 Centigrade to 70 Centigrade, with uniformity of +/- 1.0
Centigrade at 37 Centigrade
• Hydraulic thermostat to protect against temp over shoot
• Interior and exterior shall be enameled steel
• Inner glass door permit to visual inspection of samples without disturbing
contents or temperature uniformity
• Inside size 13" x 13" x 14"
• Power Supply 220V AC, 60Hz
ANNEX 2—SPECIFICATIONS
LABORATORY
(continued)
Refrigerator, Low Temp (Freezer):
• Upright Freezer
• Adjustable Stainless Steel two Shelf
• 6 Cubic It
• Storage for flammable or nonflammable material
• Enable to fit under the table
• Low noise Level (Better than 56 dB)
• Set Temperature +20 Centigrade to -16 Centigrade (+20C to -16C)
• Power Supply 220 Volt 50/60 Hz
Refrigerator:
• Upright Freezer
• Adjustable Stainless Steel two Shelf
• Storage for flammable or nonflammable material
• 6 Cubic ft
•
•
•
•
Enable to fit under the table
Low noise Level (Better than S6 dB)
Set Temperature +2° Centigrade to +8° Centigrade (2°C to 8°C)
Power Supply 220 Volt 50/60 Hz
Timer:
• With three functions: Single Action, Time In/Time Out and Continuous
• Timings read out to 59 minutes, 59 seconds and 9 tenths on LED
• With rechargeable battery with AC adapter
• Power Supply 220V AC, 50Hz or 60Hz (Adapter)
Distillation Unit:
• Produce two gallons of distilled water (Bio-pure water) per hour
• Wall fitted
• Distillate shall be pyrogen-free
• Included Storage Tank with a draw-off faucet
• Power Supply 220V AC, 50/60hz
Blood Bank Refrigerator:
• Compact Unit
• 8 cu. ft. to 10 cu. ft.
• Two Stainless Steel Drawers and with convenient flat counter Surface
• Dual Automatic controls and maintain cabinet temperature 2°c to 8°c centigrade
ANNEX 2—SPECIFICATIONS
LABORATORY
(continued)
•
•
•
•
•
•
•
Automatic off cycle defrost
Neoprene thermo-break seat
Audio/visual temperature monitor
Condensate evaporator
Included front, sides, top and interior or unit are stainless steel
Back and bottom are galvanized steel
Power supply: 220volts, 50/60hz
Urine Analyzer:
• Immediate start up the system as soon power turn on (with no warm up time or
calibration required)
• Automatic Calibration
• Large display screen with touch-sensitive action streamlines operation
• Both tone and display guide operation through each stop
• Automatic sample color determination
• 500 Samples per hour
• Perform the multiple chemistry tests
• Bilirubin, Glucose, Ketone, leukocyte, Nitrite, occult blood, protein, specific
gravity, pH
• Power Supply 100V/240, 50/60 Hz
Couch (for Blood Draw):
•
•
•
•
Electrical operated through 3 independent 24V electric motors
Four antistatic castors with the central locking system
Arms rests can be adjusted in height and locked
Power Supply 220V AC, 50/60Hz
Hot Air Sterilizer:
• Automatic hot air sterilizer assures that the temperature can reach in 5/8mins.
• Adjustable capillary thermostat 0- 210°C
• Adjustable manual timer from l0 min. to 120 min.
• Continuous service 24 hrs on 24 hour timer position
• Stainless steel chamber
• 3 stainless steel trays with 1 extractor for trays
• Suitable for laboratory instruments, glasswares, etc.
• Volume capacity: 40 to 50 liters
• Power requirements: 220volts AC, 50/60Hz
ANNEX 2—SPECIFICATIONS
STERILIZATION UNIT
Sterilizer Unit, Steam:
• Cycles: Gravity and Vacuum combination-(121 °C Pre-vacuum, 134°C Prevacuum) Leak: Test and Bowie-Dick Test
• Impact Printer/Recorder of all pertinent cycle data, Data should be printed at the
beginning and end of each cycle and at transition points during the cycle.
• Single Door, Power Door type, Stainless Steel chamber
• Automatic Controller
• Insulated Doors to reduce surface temperature of stainless steel door cover.
• Power supply, 380 3060Hz (to conform on site)
• Built in steam generator
• Chamber Size: 110 liters (or nearest volume available)
• Complete with loading trol1ey, trays and other accessories
Washer, Disinfector:
• Electric Heated
• Floor Mounted
• Microprocessor Controlled
• Chamber Load Capacity 50 liters
• Vertical sliding power door constructed of tinted, tempered glass
• Door opened or closed automatically by using the touch pads on control board if
power failure occurs door can be opened manually
• Pump powered by dual-speed motor
• Automatic detergent injection assures that the right amount of detergent is
dispensed into the water
• Provided special enzymes pretreatment for a highly effective cleaning
• Heating system enables to be achieved high temperature (95 Centigrade) and
maintained throughout the thermal rinse phase
• Drying temperature enables to set 66 Centigrade to 116 Centigrade
• Walls are well insulated for minimum heat loss
• Enable to complete the cleaning process within 26 to 33 minutes
• Complete with loading trolley, trays and other accessories.
Cleaner, Ultrasonic, Floor Mounted:
• Sonic cleaning chamber: 15 to 20 Liters
• Same size rinsing and drying chamber
• Bottom of the sonic chamber contains piezoelectric transducers powered by a
solid-state Generator
• Resonant frequency of transducers 40 to 4S KHz
ANNEX 2—SPECIFICATIONS
STERILIZATION UNIT
(continued)
•
•
•
•
Provided a radio frequency filter to prevent undesirable line feed back
between the transducers plate and the bottom of the cleaning chamber
Automatic lid opens at the end of cleaning process and closes by actuated
kick plate electrically, Same function for rinsing and drying chamber
Completely transistorized
Power Supply 220 V AC 50/60Hz
ANNEX 2—SPECIFICATIONS
PHARMACY
Cabinet Medicine:
• Size: H x W x D = 1750 x 1000 x 450 mm
• Ground mounted, Heavy Duty
• Material should be Aluminum and painted
Storage Medicine Cabinet, Two Door:
• Two hinged sheet steel doors
• Powder coated, complete
• With lock, five adjustable plastic shelves
• Pull out shelf: plastic, guiding rails of sheet steel
• 14 adjustable plastic containers, set in the inner side of doors
• Size: H x W x D = 1750 x 1000 x 450mm
• Included One medicine compartment, lockable, sliding door
• Dimension of medicine cupboard: 330 x 945 x 265mm = D x H x W
Cabinet, Narcotic, Double Door, Wall Mounted:
• Wall mounted
• Constructed of steel
• 1 shelf, double door
• Meet safety to drugs law
• Lock able
• Dimension 257 x 347 x 298 (H x W x D)
Refrigerator, Pharmaceutical:
• Capacity 6 cu ft
• Lockable
•
•
•
•
•
•
•
•
•
Adjustable thermo-state control form 1 centigrade to 10 Centigrade
With display
Temperature control +/- 0.5 centigrade at 4 centigrade
2" foamed-in-place polyurethane Insulation
With 4 Shelves, space can be increase or decrease
Vinyl, exterior coating, durable, chemical resistant
Digital display temperature read out
Built in chargeable battery for 24 hours to work capacity.
Power Supply: 220V AC, 50/60Hz
ANNEX 2—SPECIFICATIONS
PHARMACY
(continued)
Counter, Tablet, Electrical Automatic, Bench Top:
• Microprocessor controlled
• Hospital Module
• Bench top
• Enable to count 1 to 1000 tablets
• Accuracy 100%
• Power supply: 220V AC, 60Hz
Bin, Unit Dose Medication, Medium:
• Good quality Vinyl Plastic
• Unbreakable
Bin, Unit Dose Medication, Large:
• Good quality Vinyl Plastic
• Unbreakable
Bin, Unit Dose Medication, Small:
• Good quality Vinyl Plastic
• Unbreakable
ANNEX 2—SPECIFICATIONS
OPHTHALMOLOGY CLINIC
Eye Examination System with patient chair, Ophthalmic Stand with overhead lamp and
complete with slit lamp, Autokerato-refractomete, Phoroptor Unit and Autochart
Projector:
•
•
•
•
•
Ophthalmic unit complete w/ ophthalmic stand w/ overhead lamp, patient chair,
with lens bag.
Table top w/ mechanical brake can hold Slit lamp and autokerato-reftactometer
Rigid scratch resistant base
Fully integrated Main Control Panel for overhead lamp. chairs and instruments as
well as the room Light
Main power switch: 220VAC, 60Hz, 1.7KW
•
•
•
PATIENT CHAIR
o Electronically operated, Full reclining, Foldable armrest, and w/ footrest, Foot
switch, up/down capability
DOCTOR CHAIR
o Swivel stool
o 5-arm polished aluminum base with friction-braked double castors for smooth
floors
o Height adjustment by means of “anatomic-lift" gas spring
o Leatherette upholstered seat w/ backrest
VISUAL PROJECTOR
o
o
o
o
o
o
o
o
o
o
o
Auto chart projector
Remote control operation
30 Test Charts Including "E: of different sizes
Projection Magnification 30X
With Horizontal line, Vertical Line and Single Character Masking
Enables to program to project specific sequence of Charts
With tilt function
With Polarized Metal Screen
Auto Shut-Off function
Illumination by Halogen Lamp
Power supply: 220V AC, 60Hz
ANNEX 2—SPECIFICATIONS
OPHTHALMOLOGY CLINIC
(continued)
•
PHOROPTOR UNIT
o Power range:
Myopia: 0 to -19.00D
Hyperopia: 0 to +16.75D
Astigmatism: 0 to -6.0 D, increased to -8.0D w/ accessory lens
o Cross cylinder: +O.5D (+ O.25D - optional)
o Pupillary distance: 50 - 78mm
o Automatic near-point convergence mechanism
o Synchronized cross cylinders
o Rotary prism available
o Wide selection of auxiliary lenses
o Sealed Lens systems for dust and finger prints
•
AUTOKERATO-REFRACTOMETER UNIT
o
o
o
o
o
Spherical power range: - 25D to + 22D
Cylinder power range: 0 to + 10D
Axis: 0 to 180 degree
Minimal pupil diameter: 2.00mm to measure small pupil
Corneal curvature radius: 5.0 to 10.0 MM
o
o
o
o
o
o
o
o
•
Corneal refraction: 67.5D to 33.75D
PD measurement range 85mm maximum
Rotary prism measuring to enable accurate and reliable data
Auto measurement function
Built in color LCD display and printer
Stores measurement of each eye in memory
Omni directional joystick enabling operation of the machine by one hand
Corneal diameter measurement mode
SLIT LAMP UNIT
o Binocular Stereoscopic w/ erect image
o Infinitely adjustable Slit width and length
Slit length: 1mm to 8mm
Slit width: 0 to 9 mm
o Magnification: 10X to 25.6X
o Eyepieces: 10X to l6X
ANNEX 2—SPECIFICATIONS
OPHTHALMOLOGY CLINIC
(continued)
o Slit Beam Inclination: up to 20 degree
o Four built in printers: Cobalt blue, Red – free, Neutral density, and Heat
absorbing
Ophthalmoscope, Indirect:
• Compact and light weight
• Enables to raise and lower the light source without converging the viewing optics
• Scratch resistant coated optic
• Brilliant natural halogen illumination
• Illumination rheostat shall be located on the hand band
• Built in UV, Blue and Red free filters
• Minimum pupil diameter: 2mm
• Pupillary distance adjustable from 52 to 76 mm
• Power supply: 220V AC, 60Hz
• Included carrying case. Battery pack set
Lensometer with Marking Device:
• Fully automated operation
• LCD display (320 x 240dot). showing the indication of Single, right-left, prism,
addition, S.C.A, Abbe
• Built in Printer
• Enables to measure Frame Lenses, Contact Lenses. Bifocal and Progressive
Lenses
• Identifies Progressive Lenses
• Spherical Power range: 0 to +/- 25D
• Cylinder Power range: 0 to +/- IOD
•
•
•
•
Cylinder Axis range: 0 degree to 180degree
Prismatic power 0 to 10 Prism
Lens Diameter: 5 to 98mm
Power Supply; 220V AC. 60 Hz
Lenses, Trial, Complete Set in Case:
• Included lenses, trial frame, accessories and case
Trial frame:
• Light weight durable metal construction
• Horizontal and Vertical frame
• Adjustable Mechanism assures comfortable nose fit of different sizes
ANNEX 2—SPECIFICATIONS
OPHTHALMOLOGY CLINIC
(continued)
• Separate PD adjustment for each eye
• Individual adjustment for Temple Length and angle
• Adjustment for rotating cylinder to correct the axis
• The frame on the ear is extendable or reduce able
• Space for setting 4 lenses at a time
• Scale with large, easy to read numerals
Trial lens:
• Lenses are marked on one side only to ensure correct position in the frame
Lenses have sturdy, light weight aluminum rings that are different color
coded and marked for fast, positive identification for minus, plus, prism and
accessories
• Lenses cemented and firmly clamped to ensure precise alignment
• 260 Pieces of lenses
• Included prisms and accessories included, Stand with Carry Case
• On four castor, two castor brake able, Case removable from the stand
Sternest (Stereoposis Test Book or Drawing):
• Complete Kit
• Included glasses, book, occluder.
• Enable to use for adult and pediatric
Retino Scope:
• Enable to use either streak or spot beam with simple bulb change
• Neutralization check to allow rapid of neutralization in both streak and spot
modes
• 360 degree access to single control for both rotation and convergence
adjustment
• With rechargeable batteries
• Included table top Charger
Tonometer, Opthalmic:
• Portable measurement of eye Intraocular Pressure
• Battery operated with digital display
Binocular Loop:
• Spectacle frame or head band mounted
• With three stages magnification 2.0X, 2.5X, 3.0X and wide range of working
distances
ANNEX 2—SPECIFICATIONS
OPHTHALMOLOGY CLINIC
(continued)
•
•
•
•
With optical alignment reduces eyestrain
With Individual interpupillary adjustment allows adjustment allows more than
one user's to benefit
Constructed of high quality light weigh glass and light weight aluminum
Flip-up magnification during when not in use
ANNEX 2—SPECIFICATIONS
DENTAL CLINIC
Dental Chair Unit, Complete:
• Dental Chair:
o Chair base
o Back rest
o Headrest: push headrest in or pull it out to suit the patient height. Bring the
headrest to the desired position.
o Armrest: easier for the patient to get into dental chair, the arm rest can be
swiveled upward.
o Seat adjustment control
• Unit base:
o Supply element: connection of electric (110/220 volts, 50/60Hz)
Water pressure: 2.5 - 6bar
Air pressure: 5.2 - 7bar
Suction air: > 65mbar at inlet
Waste water drainage
o Main fuse
o Main switch
• Unit body w/ Patient Parts:
o Spittoon
o Tumbler filler
o Central control is housed in the unit body Pressurized water bottle
o Footswitch controller
• Assistant elements:
o Three function Syringes
o Suction tubing
o Comfort keypad and display
o Saliva ejector
o PolyLux handpiece
• Dentist elements:
o Three function Syringe
o Keypad and display
o
o
o
o
o
Locking brake
Compact X-ray viewer
Tray support
Scaler
Alternatively intra Lux motor Turbine
ANNEX 2—SPECIFICATIONS
DENTAL CLINIC
(continued)
•
•
•
•
Keypad Functions:
o Group A:
Dental chair up or automatic position
Dental chair down or automatic position (rinse position)
Backrest up or automatic position
Backrest down or automatic position
Last position or automatic position
o Group B:
X-ray viewer
Flushing of spittoon bowl
Tumbler filler
Cold light at the instrument
Spray selection at the removed instrument
Motor reserve pre-selection treatment light ON when instrument set down
Dental chair plate safety switch
Dental Chair/Foot Control:
o Foot control switch for chair up, down, backrest up, backrest down, load
position automatic operation
Dental Unit Foot Control
o Switch for foot control "ON" of the unit, spray indication, ccw/cw motor
operation
Dental Light:
o The Lighting unit has removable (autoclave-able) handles
o Light output of 25000 lux, highlight performance fan cooled bulb ensures
optimum illumination that is indistinguishable from natural daylight.
Dental Stool:
o Doctor Stool
Cast aluminum base with five casters
Seamless upholstery
Integral gas cylinder for height adjustment
Two way adjustable lumbar support
Seat height range 18.0 inch - 25 inch (470mm-635mm)
o Assistant stool:
Cast aluminum base with five caster
Seamless upholstery
Integral gas cylinder for height adjustment
Height adjustable torso support
ANNEX 2—SPECIFICATIONS
DENTAL CLINIC
(continued)
Height adjustable foot ring
Seat height range: 22 inch - 29 inch (572mm-737mm)
Amalgamator:
• Microprocessor controlled
• Touch pad controls
• Led Display
• Programmable preset memories
• Spring tensions, molded capsule holder
• Timer 1-30 seconds
• Cycle speed 4200 CPM - 3600 CPM
• Sealed mix area
• Accepts all types of capsules including amalgam and ionomer
• Power requirements: 110 volts/220volts, 50/60Hz
Light Curing Unit:
• 450mw / cm2 minimum curing output
• 3 to 13mm light guide selection
• 360 rotation light guide
• Autoclavable and sterilizeable light guide
• 100 hours lamp life
• Ultraquite cooling fan
• Pistol handpiece with trigger activated blue light
• Audible tones every ten seconds for curing time control
• Eye protection shield
Film Processor, Dental:
• Daylight dental film processor with automatic program control
• Removable baths for developer, fixer and water for cleaning
• Inclined viewing window for easier observation of internal working process
• Thermostatically-controlled bath heating and film drying
• Complete with film clip for all miniature format and standard intra-oral film
• Power supply: 110v/220volts, 50hz/60hz
Dental X-Ray Unit:
• Wall mounted w/ 45 or 90cm extension arm, folding arm
• Compatibility with Digital Intra Oral Radiology machine
• Automatic set up of working conditions by selections of patient size (child
or adult), and tooth type
ANNEX 2—SPECIFICATIONS
DENTAL CLINIC
(continued)
•
•
•
Tube head is equipped w/ beam limiting device (collimation) and a tiny
focal spot compatibility with Digital Intra Oral Radiology machine
Microprocessor controlled electronic timer
Digital display of exposure time in seconds
•
•
•
Special low dosage switch to work w/ digital imaging sensor.
Safety leakage radiation
Mains voltage (selectable 110volts/220 volts, 50/60Hz w/ +/-10% correction
of mains fluctuation
Dental Scaler Unit:
• Titanium hand piece for cool and long life operation
• Powerful scaling for the most stubborn stains and calculus
• No heat generation of hand piece even under persistent use
• User control of delivered power and water supply
• Equipped w/ endodontics function providing easy and rapid root canal
enlargement and treatment
• Standard accessories: Hand piece, 3 tips, torque wrench, foot switch, power cord
and hose
• Output frequency: 29khz, Delivered power: 20 watts, Hand piece cable:
2.5m
• Mains supply: 100 - 240volts, 50/60Hz
Dental Cabinet System with Sink:
• Made of electrogalvanized, cold rolled steel
• The work tops are made of post-form laminated scratch-proof plastic
• Equipped w/ sink - a long lever mixer faucet for hot/cold water, and a
waste bin
Dental Instrument Table, Mobile:
• Made of electrogalvanized cold rolled steel
• Four (4) drawers with locking mechanism and locking castors
Ultrasonic Cleaner:
• Provides quick, effort less and thorough cleansing of delicate difficult to clean
dental instruments
• Cleaning temperature: 10°C to 70°C
• Power requirement: 110V/220V, 50/60hz
ANNEX 2—SPECIFICATIONS
DENTAL CLINIC
(continued)
Autoclave Unit, Dental:
• Capacity 17 liters (Bench top)
• Microprocessor management and digital display
• Automatic functioning
• Thermodynamic initial vacuum
• Thermical drying system
• Fully automatic chamber water filling and safety mechanism
ANNEX 2—SPECIFICATIONS
ENT CLINIC
ENT Treatment Unit, Complete:
• Ergonomic arrangement of mirror heating, light source switching and control for
suction and compressed air
• Central operating and display panel
• Automatic control of all pumps and light sources
• Suction performance (max. 55 li/min) for all ENT applications
• Maintenance free and vibration free suction pump
• Service compartment of pump area easily accessible for doctor and staff
• Endoscope storage with integrated heating and optical system/ lightsource
• Connection for head lamp! Nystagmus binoculars complete with headlamp
suspension automatic switching function of the light source
• Cabinet with two fold instrument deposit with subjacent writing and working
plate with integrated tongue patches and swab dispenser
• Integrated removal deposit tray for used instrument and for safe hygienic
instrument management
• Endoscopy programme to document and visualize doctors finding
• Microscopy integration with light source control on the tmit and expandable with
camera system and LCD Oat screen
• Ear and hose rinsing system, independent of water supply and waste water
connection and complete with general accessories.
• Adjustable power source for warm light headlamp, cauterization and complete
with accessories
• Patient Chair, electromotive height adjustment, rotary seat
• Doctor Chair with height adjustment and back rest
Audiometer, Clinical:
• Large backlight graphical LCD display
• True two channels include microphone, assistant phone
• Automatic data transfer to computer and data printer
• Test signals: pure, pulse, warble tone, narrow band, white and speech masking
noise with two channels
• Inputs: CD/Tape, stereo live speech microphone, external masking, patient
microphone, patient response switch
• Air conduction range: -10 to 120dB, include headphone
• Bone conduction range: -10 to 70db
• High tone audiometry for AC to BC 16khz
• Free field range: -10 to 90dB at 1m distance include speaker 120dB
• Selectable range of Test frequencies
ANNEX 2—SPECIFICATIONS
ENT CLINIC
(continued)
Middle Ear Analyzer:
• Fast, full automatic tympanometric test
• Ipsi and contralateral reflex test with 4 frequencies
• Reflex test with adjustable levels from 70 to 10Sres. 70 - 110db or automatic
• Reflex decay testing, Eustachian tube function test
• Fast integrated printer and PC interface
ANNEX 2—SPECIFICATIONS
X-RAY
X-Ray Unit, General:
• Adjustable Patient Table variable from 59 to 89 cm with foot control pedal
located on both front and rear of table to allow easier patient positioning
• Longitudinal/lateral electromagnetic and electromechanical locks to provide
safety and security
• Floor mounted tube radiography system allow easy positioning with flexibility
and functionality to accurately position the tube in all radiographic procedures
• Bucky wall stand (adjustable height) with cassette function using automatic
cassette size sensing
• Collimator (manual or automatic) which effectively limits the field of exposure
during radiography and an easily changeable collimator bulb
• Frequency generator available in 4 power configurations of 30/ 50/ 65/ 80KW
• Self calibrating variable frequency operation delivers higher accuracy, sharter
exposure time and lower patient dose
• Control-console includes manual mode technique and parameter control,
anatomical programmer, and automatic exposure control
X-Ray Film Processor, Bench Top:
• Rapid processing cycles for fully processed 35x43 cm (14x17 in) radiograph, dry
and ready to read
• Automatically feeds exposed films into the processor
• Processing tanks molded in polyurethane with three sections for developer, Fixer
And washer
• Thermistor/logic circuit, water heat exchanger, and developer recirculation system
control developer temperature to +/- 2°C
• Dryer temperature control is thermostatically controlled and easily adjustable
• Automatic standby control when no film is processed and reduces water
consumption.
• Power requirements: 110volts/220volts, 50/60hz
X-Ray Film Viewer, Double:
• White enameled steel casing
• Edge to edge viewing
• Clear Perspex spring-loaded film clips
• Twin Tropical Daylight tubes with illuminated switching per panel
• Dimensions: Height x Width = 505 x 724 mm
• Power Supply: 110V/220VOLTS, 50/60HZ
ANNEX 2—SPECIFICATIONS
X-RAY
(continued)
Apron Patient Protective:
• Flexible lead rubber in tear resistant plastic cover
• Sleeveless, half length at back
• Fastening with crossed elastic straps with Velcro end
•
0.5 lead thickness for small, medium and large sizes
X-Omatic Identification Camera, Digital:
• Enables to print patient data digitally with the a11 types of cassette
• Portable and built in battery power
• Adjustable exposure light intensity
• Films and Cassettes: alll5mm cassettes with standard ID window Film size: all
film types
• Imaging: Enables to both black on white and white on black exposures
• Characters: Standard font: 4 lines of38 characters Larger font: 4 lines of28
characters
ANNEX 2—SPECIFICATIONS
PRIMARY CARE CLINIC
Examination Table:
• Rectangle steel tube frame, chromium plated
• 2 section
• 70 mm thick foam robber upholstery
• Reclining head section
• Adjustment by means of clamp lever
• With leveling feel
• Included paper roll holder, 500 mm wide
• Dimension: 650 x 1950 mm
Vital Signs Monitor:
• Parameters include NIBP, Sp02, and Temperature, Pulse rate.
• Large LED Display able to seen 1 meter distance
• Color Coding clearly presents parameters data second by second
• Built in Printer
• Internal rechargeable battery operating life Minimum One hour
• Technique Automatic Oscillometric
• Range 0-255 mmHg Accuracy +/- 2 mmHg
• Cuff inflation 3 to 20 seconds
• With Alarm for Systolic and Diastolic
• Pulse Oximeter Range 0-90 %, Resolution 1 %
• Accuracy +/- 2%
• Heart rate Range 0-250 bpm, Resolution I bpm, Accuracy +/- 1 bpm
• Power Supply 220 Volt 60 Hz
Suction Regulator:
• Included regulator, jars, probe (inlet fitting British standard), rail mounted, and
hose.
• With overflow safety trap
• Internally well designed with the increments in cmH20 & kPa to give accurate
vacuum by precision regulating diaphragm
• With two scales -mmHg and -kPa
• With three modes Off, On and Max.
• With the feature of positive pressure relief valve vents accidental positive
pressure away from patient and system
•
•
Two modes high continuous Gauge 0-100KPa
Flow rate 0-80 l/min
ANNEX 2—SPECIFICATIONS
PRIMARY CARE CLINIC
(continued)
OTO/Ophthalmoscope:
• Diagnostic Set
• Battery Handle with chargeable batteries
• Charging holder with the transformer
• Ophthalmoscope with halogen bulb
• Otoscope head with halogen bulb
• One each reusable ear speculum sizes: 2, 3, 4 and 5mm
• Five each disposable ear specula 2.5 and 4.0 mm
• One magnifying glass for operation 2.5
• With spare bulb
Thermometer Electronic:
• Liquid Crystal Display
• Enables to read in Celsius/Fahrenheit
• Probe storage
• Temperature range: 31.6 centigrade to 42.2 centigrade
88.9 Fahrenheit to 108.0 Fahrenheit
• Accuracy +/- 0.1 C +/- 0.2 F
• Information display, Monitor mode, rechargeable battery, return to base charger,
battery low, Broken probe
• Power requirements: 220volts AC, 50/60hz
Gulcometer:
• Hospital Module
• Enable to use individual strip
• Built-in rechargeable batteries and with battery charger
• Power Supply 220V AC, 60Hz
Scale Standing Digital:
• Electronic Scale with large display
• Enables to show TARE, HOLD and BMI
• Graduation 100 gm/ 0.2 Lbs
• Enable to switch over to lbs-kgs
• With Transport Castors
• With rechargeable batteries, built in adopter
• Power Supply 220 V AC, 60Hz
ANNEX 2—SPECIFICATIONS
PRIMARY CARE CLINIC
(continued)
Suction, Portable:
•
•
•
•
•
•
•
•
•
•
•
Air flow rate: 18 l/min
Vacuum-meter: 0 to 1 Bar
1.5 liter bottle
With Grip & Bacterial filter
Suction device sterilize-able
Over flow protection
Two meter silicone-suction tubing
Dimension approx: W x H x D = 320 x 140 x 255
Rechargeable built in battery
Approx. Weight: 3 to 4 Kg
Power Supply 220 Volts 60 Hz
Examination Light:
• With the stand and four Castor made of quality material
• Base Five arm on Castors
• Flexible (Swan neck system)
• Chromium-plated arm
• 50W Halogen cool bulb, provided spare Bulb
• Built in Auto transformer
• Power Supply 220V AC, 60Hz
Laryngoscope Set:
• Size Standard
• Blade type Macintosh in quantity number three (3) Large, adult and child with
Lamp installed
• Fitting Blade: hook on fitting
• Tip adjustable on the blade to provide the Clinician with greater flexibility,
especially in cases of difficult incubating
• Uses four different angles between the blade and handle i.e. 90 degree, 45degree,
180 degree and 135 degree (Standard)
• With four locked position light remains illuminated during changing from one
position to another
• Blade is McCoy type
• Blade hook on fitting
• Tip adjustable on the blade to provide the Clinician with greater flexibility,
especially in cases of difficult incubation
• Complete Set provided in Zippered Case.
ANNEX 2—SPECIFICATIONS
PRIMARY CARE CLINIC
(continued)
X-Ray Viewer, Single:
• White enameled steel casing
• Edge to edge viewing
• Clear Perspex spring-loaded film clips
• Twin Tropical Daylight tubes with illuminated switching per panel
• Dimensions: Height x Width = 505 x 724 mm
• Power Supply: 22Ovolts, 50/60hz
Oxygen Flow Meter with Humidifier:
• Direct fitted to the Outlet (British Standard), included with the Humidifier.
• Nickel-plated brass base and body
• Clear shroud
• Expanded lower scale 0-5Lpm
Sphygmomanometer, Wall Mounted:
• Wall mounted or rail fitted as hospital requirements
• 6 in. to 8 in. diameter anemometer
• 7ft extendable neoprene tubing
• Easily read scale
• Pair of cuff for adult and child
• Cuff able to fits neatly at instrument grilled basket
ANNEX 2—SPECIFICATIONS
IN-PATIENT UNIT
Patient Bed, Electric:
• Integrated collapsible side rail w/ control and Foot Board control with lock out
• Electrical Controlled Movement: Bed up/down: 74cm/36cm
Backrest: 0 - 65 Deg
Knee Gatch: 0 - 24 Deg
Trend/Rev. Trend: +/- 14Deg
• Weight Capacity: 500lbs (228kgs)
• Supplied with Bedside cabinet and Table Top Server
• Power requirements: 220 volts, 60 HZ
• Lowest Height of 13.5 inch (34.30 cm), enhances patient safety
• Mobile on four double castors to be activated by foot pedal.
• Complete w/ IV receptacle and IV pole
Vital Signs Monitor with Trolley:
• Parameters include ECG, NIBP, Sp02, Pulse rate and Temperature
• Large LED Display easily able to seen 3 meter distance
• Color Coding clearly presents parameters data second by second
• Built in Printer
• Internal rechargeable battery operating life Minimum two hour
• Technique Automatic Oscillometric
• Range 0-255 mmHg Accuracy +/- 2 mmHg
• Cuff inflation 3 to 20 seconds
• With Alarm for Systolic and Diastolic
• Pulse Oximeter Range 0-90 %, Resolution 1 %
• Accuracy +/- 2%
• Heart rate Range 0-250 bpm, Resolution 1 bpm, Accuracy +/-1 bpm.
• Power Supply 220 Volt 60 Hz
Infusion Pump:
• The volumetric infusion pump for routine tasks and intensive care medicine for
use in all wards
• Microprocessor controlled
• Leakage current should be less than 10 micro ampere
•
•
•
•
Delivery range 1-999 ml/hr
Smallest entry step 1ml/hr or 0.1ml/hr in a range of 1.0-999ml
Delivery precision +/- 5%
Delivery volume pre-setting up to 999.9 ml
ANNEX 2—SPECIFICATIONS
IN-PATIENT UNIT
(continued)
•
•
•
•
•
•
•
•
•
•
•
•
•
Function spectrum/Safety system Stand by, drug selection, cc interface operation,
pressure limit selection, deactivation of drop control, display of battery capacity,
data clock.
Permanent visualization Delivery rate, current volume, pressure limit battery or
main driven, mains control, running control.
Info-query Infusion status, current and total volume remaining volume.
Mains/Battery operation
Voltage 220V, 60Hz
External low Voltage 12
Battery type NiCd, rechargeable
Battery operated time approx: 3.5 hrs
Mains/Battery operation
Voltage 220V, 60Hz
External low Voltage 12
Battery type NiCd, rechargeable
Battery operated time approx: 3.5 hrs
Oxygen Flow Meter with Humidifier:
• Direct fitted to the Outlet (British Standard), included with the Humidifier.
• Nickel-plated brass base and body
• Clear shroud
• Expanded lower scale 0-5Lpm
Suction Regulator:
• Inc1uded regulator, jar, probe (inlet fitting British standard), rail mounted, and
hose.
• With overflow safety trap
• Internally well designed with the increments in cmH20 & kPa to give accurate
vacuum by precision regulating diaphragm
• With two scales -mmHg and -kPa
• With three modes Off, On and Max.
• With the feature of positive pressure relief valve vents accidental positive
pressure away from patient and system
• Two modes high continuous Gauge 0-100 KPa.
• Flow rate 0-80 1/min
Annex (3)
Specification of a long chassis truck 6 x 4
Item
Manufacturer
Qty
Model
Description
Number
Country
Long
Freightliner
27
Chassis
Truck
U.S.A.
4900
Engine: Diesel engine (turbo
charger)
Number of cylinders:
Minimum 6
Horsepower: 400 minimum
Engine cooling: via cooler not
less than 100 liters in capacity
Gearbox: full automatic with 16
F speeds
Tires and rims: minimum 6 tires
plus a spare tire fitted with
loading and unloading winch
Diesel tank: capacity minimum 400
liters
Steering wheel: hydraulic
3 year warranty
10 year parts availability
Annex (4)
Specification of a Forklift
Item
Manufacturer
Qty
Number
Country
Forklift
3
Hyster
U.S.A.
Model
Description
P300
Load: 12 ton which it can lift up
to 3 meters
Engine: Diesel engine with 160
HP at least
Number of cylinders: 6
Fork: Length minimum 2 meters.
Can be moved right and left.
Height up to 4 meters, thickness
minimum 82 mm. Width
minimum 180mm.
Fuel: Diesel
Safety System: The equipment
will not move until after the
driver has sat on the driver’s
seat.
Can be shipped on C 130 aircraft.
That means its width is not more
than
2.4 meters and its height is not more
than 2.4 meters.
Annex (5)
Specification of trailers (low beds)
Item
Manufacturer
Qty
Number
Country
Low bed
3
Fontaine
Model
Description
Lowboy
Design: low bed
U.S.A.
Capacity: 60 tons
Suspension system:
1. Tri-axel, 16000 kg each
(48000 kg for all axels)
2. Leaf spring
3. (12) Michelan tires, size
12R 20, double configuration
for each end designed for
paved and unpaved roads
(highway and off highway
use).
4. (2) spare tire with the same
above mentioned specifications
Dimensions:
1. Low bed length (15m)
2. Low bed width (3.2m)
3. Deck height not exceeding
(1.25m) without load
Annex (5)
Specification of trailers (low beds)
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
Brake system: Two lines air brake
systems works on all tires.
Additional manual brakes during
stop.
Kingpin: 3.5 inches, fixed on the
upper sliding plate (gooseneck).
Front legs: High performance,
mechanical, two speeds, flat
stands.
Electrical system: 24V electrical
system. Trailer shall be fitted
with rear lights, signal lights and
side lights.
Accessories: The trailer must be
fitted with the following:
1. (2) spare tire holders
2. (2) tire rooming
3. Mud flaps set
4. Lockable toolbox
Annex (5)
Specification of trailers (low beds)
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
5. Sixty liter potable water
tank
6. Tire replacement tools
containing an additional
long rod for lifting during
removal/replacement.
Hydraulic jack capable of
lifting (1) loaded axle.
7. Set of (6) connecting chains
(6m) each including drops.
Each chain must bear at least
(10) tons.
8. (2) air connecting points on
both right and left sides above
the axles. Air points disconnects
quickly and are linked to the
trailer’s air system.
9. Air hose, minimum length (5m)
fitted with a (male) fast connecto Annex (5)
Specification of trailers (low beds)
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
Tire air pressure gauge
containing
both systems and clear
numbering
and ranges between 0 and 160
PSI.
Towing tools: Trailer shall be fitted
with a towing winch at the front of
the low bed (fixed) to tow vehicles.
Capacity 25 tons. Annex (6)
Specification of a Flat Bed Trailer
Item
Manufacturer
Qty
Number
Country
Flat Bed
3
Chaparral
Model
Description
2001
Length: 12.5 meter
U.S.A.
Height: Not more than 1.25 from
the ground.
Axles: 2 axles with 4 tires each,
long springs.
Resting legs: Front, match loads,
works with two speeds, flat base.
Flatbed width: 3 meters
Base: The main cover of iron
sheet granular not less than 5mm
thick, longitudinally welded in
full without voids.
Annex (6)
Specification of a Flat Bed Trailer
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
Towing pin: 3.5 inches fixed on the
upper sliding plate (gooseneck).
High quality paints treated for
harsh climatic resistance.
(2) spare tires.
Potable water tank and tool boxes.
Side climbing ladders to the flatbeds.
5-year warranty of welding and
compiling works and a 1-year
warranty
on the support legs and hydraulic
system.
Matching illumination and signal
system.
Annex (6)
Specification of a Flat Bed Trailer
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
Airbrakes for axles.
Electric link system with towing
heads.
Additional loading chains.
Chassis 40 cm.
Annex (7)
Specification of a Refrigerator Truck
The vehicle comprises a chassis + box + a refrigeration unit
Item
Manufacturer
Model
Qty Unit Price
Total Price
Number
Country
(USD)
(USD)
Description
Vehicle
6
Specifications
1. Engine: diesel 6 cylinder
Freightliner/
M2106
Mercedes
U.S.A.
2. Engine power: minimum 120
horse
3. Cooling: water cooling specially
designed for hot regions.
4. Steering: power steering.
5. Tires: (6) tires + spare tire of the
same size and best international
quality brands.
6. Location: rear
7. Fuel tank capacity: 100 liter
minimum
8. Gear: floor (ground) engagement
–
5 speed and one rear speed.
9. Brakes: hydraulic
10. Payload: 5 tons minimum
11. Chassis length: minimum 5 m
12. General fittings: first aid kit +
warning triangle + fire
extinguisher
Annex (7)
Specification of a Refrigerator Truck
The vehicle comprises a chassis + box + a refrigeration unit
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
+ tire air pressure gauge meter
13. Latest model: 2008
The Box
1. Length: minimum 5 meters
Width: minimum 2 meters
Height: minimum 2 meters
2. Special material (wood of
appropriate
thickness or other) between the
vehicle’s main chassis and the
box’s
chassis to absorb shocks.
3. Doors:
(2) rear doors at the full box
opening
(1) side door for necessary
loading
and unloading
Galvanized, pre-painted metal
sheets from inside and outside.
Annex (7)
Specification of a Refrigerator Truck
The vehicle comprises a chassis + box + a refrigeration unit
(continued)
Item
Manufacturer
Qty
Number
Country
Model
Description
4. The iron used inside the walls,
floor and doors shall be
galvanized stainless steel.
Refrigerator
Specifications
1. Works by vehicle engine and
without it.
2. Sufficient to cool the box.
3. Of a known brand.
4. Cooling temperature ( 5-20C )
Other
Specifications
1. Install a rear bumper of hard iron
to protect the box from shocks.
2. Install mud flaps to protect rear
tire from mud.
3. Internal light (2) lamps. External
front light (2) lamps, all
controlled
from driver’s cabin.
Annex (8)
Service Vehicle Specifications
Item
Manufacturer
Qty
Number
Country
Service
12
Vehicle
General Motors
U.S.A.
Model
Description
XL1500
1. (8) cylinder, 4.5 liter at least,
250 HP minimum power.
(4) doors.
Automatic gearbox.
Electronic fuel injection.
Aircushion for driver and front
passenger.
6. ABS brake system.
7. Hydraulic steering wheel.
8. Electric side mirrors
9. Electric window glass.
10. Central locks.
11. Hot/Cold AC.
12. Speed fixer.
13. Radio cassette.
14. Latest model: 2008
15. 3 year warranty Annex (9)
Four-wheel drive Vehicle Specifications
2.
3.
4.
5.
Item
Manufacturer
Qty
Number
Country
Four-
General Motors
3
Wheel
Drive
Vehicle
U.S.A.
Model
Description
XL2500
Speeds: 5 speeds manual.
Passenger Number: 7
passengers minimum.
Fuel: Benzene
Fuel tank capacity: two tanks,
main and spare, total tank
capacity 130 liters.
Other specifications:
4 doors.
Hydraulic, adjustable steering wheel.
Front adjustable mattresses.
Hot/Cold AC.
Radio cassette.
Aircushion for driver and front
passenger.
Central locks.
Electric window glass.
3 year warranty.
Shipping / Delivery / Set-Up
Item
Number
1
2
Specifications
Qty
Trailer / Hospital
Generator
1
1
3
Tanker (fuel)
1
4
Trucks / autos
1
5
Miscellaneous containers
1
6
Additional shipping
1
7
Crates / Shipping Materials
1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement