Halsey Taylor 5904.B Water Coolers-Drinking Fountain Owner Manual
Halsey Taylor 5904.B is a wall-mounted steel fountain designed for easy installation and reliable performance. It features a 3/8" O.D. unplated copper water line connection and a 1-1/4" O.D. drain line connection. The fountain operates on a water supply pressure of 20 to 105 psig and is equipped with a pressure regulator to prevent damage from higher pressure. It includes a regulator retaining nut, regulator, hex nut, regulator holder, basin, strainer plate, drain plug, gasket, locknut, slip nut gasket, tailpiece, slip nut, bubbler gasket, bubbler, bottom cover, and bubbler tube.
Advertisement
Advertisement
5904*B FOUNTAIN
Halsey Taylor Owners Manual
Wall Mount Steel Fountain
INSTALLER
Halsey Taylor Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING
AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
1. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" O.D. tube. Contractor to supply waste trap and
service stop valve in accordance with local code.
2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter
before being connected to fountain. This fountain is manufactured in such a manner that it does not in
any way cause taste, odor, color, or sediment problems.
3. Connect the 3/8" O.D. unplated copper water line from the fountain to the service stop valve. (see Fig.3) DO
NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY
RESULT.
4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure is
above 105 psig, a pressure regulator must be installed in the supply line. Any damage caused by reason
of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig is not
covered by warranty.
PAGE 1 97101C (Rev. A - 5/98)
5904*B FOUNTAIN
97101C (Rev. A - 5/98) PAGE 2
LEGEND/LEYENDA/LÉGENDE A
5904*B FOUNTAIN
START UP INSTRUCTIONS
1. This fountain is to be mounted on a smooth, flat, finished wall surface with adequate support structure.
NOTE: Wall mounting structure must be capable of supporting 300 lb. load on fountain.
2. Establish rim height that fountain is to be mounted at.
3. Refer to rough-in for plumbing.
4. Locate and install trap.(trap not furnished)
5. Install shut-off valve on building water supply.(valve not furnished)
7. Locate and install fountain using 3/8" minimum lag screws or bolts. (screws or bolts not furnished)
CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator
should be used if the inlet water supply exceeds 105 PSI.
8. Connect water supply and fountain drain.
9. Turn on water supply and check all connections for leaks.
OPERATION OF QUICK CONNECT FITTINGS
Simply Push In Tube
To Attach
Tube Is Secured In
Position
Push In Collet To
Release Tube
A B C
Pushing Tube In Before
Pulling It Out Helps To
Release Tube.
FIG. 2
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER INLET
NOTE: WATER FLOW
DIRECTION
FIG. 3
STREAM HEIGHT ADJUSTMENT: Stream height is factory set at 35 PSI.
If supply pressure varies greatly from this, remove items 1 & 2
(see Fig.5) and adjust screw on item 4. Clockwise adjustment
will raise stream and counter-clockwise adjustment will lower
stream. For best adjustment, stream should hit basin approx.
6-1/2" from bubbler.
SERVICE STOP
(NOT FURNISHED)
FIG. 4
PAGE 3
CORRECT STREAM HEIGHT
97101C (Rev. A - 5/98)
ITEM NO.
13
14
15
16
9
10
11
12
7
8
5
6
3
4
1
2
17
18
NOT SHOWN
ITEMIZED PARTS LIST
PART NO.
40089C
40048C
15005C
61313C
40169C
50986C
172613642830
160270508640
161637308640
100147140560
110346220550
100352940560
160356008550
160346308640
100322740560
51546C
23045C
62306C
55996C
DESCRIPTION
Cover
Button
Regulator Retaining Nut
Regulator
Hex Nut
Regulator Holder
Basin
Strainer Plate
Drain Plug
Gasket
Locknut
Gasket - Slip Nut
Tailpiece
Slip Nut
Bubbler Gasket
Bubbler
Bottom Cover
Bubbler Tube
Strainer
5904*B FOUNTAIN
TROUBLE SHOOTING AND MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire. CAUTION: DO NOT file or cut orifice material.
Stream Regulator: If orifice is clean, regulate flow as in START UP instructions above. If replacement is necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.2) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately
3/4".
7 15,16 SEE FIG. 6
18
SEE FIG. 5
17
1 2 3 4 5 6
8
10
12
14
FIG. 5
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
97101C (Rev. A - 5/98)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 4
FIG. 6
9
11
13

Public link updated
The public link to your chat has been updated.
Advertisement