735-B - Bradford White
Commercial Flue Damper Electronic Ignition
Energy Saver Gas Water Heater
Photo is of
D-75T-125-3N
FEATURING:
The Commercial Flue Damper Models feature:
■ ICON HD™—Intelligent proven design combines temperature control,
diagnostic codes, and system ignition functions into a single control board
with a digital LCD display. Control panel cover tilts down for ease of wiring
and service.
■ Operation Mode—Two different digitally displayed operation modes have
the capability of adjusting the temperature setting up to 180°F (82°C), and
adjusting the degree setting (ºF to ºC, or ºC to ºF).
■ Service Mode—Eight different digitally displayed service modes can be
easily cycled through by pressing the select button. There is the capability
of adjusting the temperature setting up to 180°F (82°C), adjusting the
degree setting (ºF to ºC, or ºC to ºF), locking the maximum temperature
setting that can be adjusted in operation mode, displaying the average
water temperature (if water heater has two sensors), displaying the upper
temperature sensor, displaying the lower temperature sensor, displaying the
flame current of the pilot flame, and displaying diagnostic codes.
■ Electronic Ignition—High voltage, low current electricity is sent to the pilot
electrode initiating a spark to ignite the pilot gas. This results in savings of
pilot gas during stand-by periods because the pilot flame only operates
when there's a call for heat.
■ Automatic Flue Damper—Reduces stand-by loss, saving gas consumption
and improving overall efficiency.
■ Factory Installed Hydrojet® Sediment Reduction System—Cold water
inlet sediment reducing device helps prevent sediment build up in the tank.
■ Vitraglas® Lining—Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the
highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the
steel surface by firing at a temperature of over 1600ºF (871ºC).
■ Non-CFC Foam Insulation—Covers the sides and top of tank, reducing
the amount of heat loss. This results in less energy consumption, improved
operation efficiencies and jacket rigidity.
■ Water Connections—Factory installed true dielectric waterway fittings
extend water heater life and eases installation. Multiple water connection
locations allow for greater installation flexibility.
■ Hand Hole Cleanout—Allows inspection of tank interior and facilitates the
removal of sediment deposits.
■ E.C.O.—An automatic re-set Energy Cut Off (E.C.O) shuts off all gas in
event of an overheat condition. This automatically re-sets when operation
conditions are back to normal.
■ Magnesium Anode Rods—Provide added protection against corrosion for
long trouble-free service.
■ Sanitizing Capability—Temperature setting up to 180°F (82°C).
■ ASME Code Available on all Models Above 200,000 BTU/Hr.
■ NSF Construction Available.
■ Low NOx Construction Available.
■ North Carolina Code Compliant.
■ T&P Relief Valve—Installed.
■ Brass Drain Valve—Tamper proof.
■ Design certified by CSA International.
3-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
735-B-0315-A
Commercial Gas Water Heater
Electronic Ignition Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
D-38T-155-3N+
D-75T-125-3N
D-75T-160-3N
D-80T-180-3N
D-80T-199-3N
D-80T-250-3N(A)
D-100T-199-3N
D-100T-250-3N(A)
D-75T-300-3N(A)
D-65T-370-3N(A)
D-65T-399-3N(A)**
D-80T-425-3N(A)
D-80T-505-3N(A)
D-100S-199-3N
D-100S-250-3N(A)
D-100L-199-3N
D-100L-250-3N(A)
D-100L-270-3N(A)**
D-100L-300-3N(A)
D-80L-399-3N(A)
D-80L-450-3N(A)
D-80L-505-3N(A)
Model
Number
D-38T-155-3N+
D-75T-125-3N
D-75T-160-3N
D-80T-180-3N
D-80T-199-3N
D-80T-250-3N(A)
D-100T-199-3N
D-100T-250-3N(A)
D-75T-300-3N(A)
D-65T-370-3N(A)
D-65T-399-3N(A)**
D-80T-425-3N(A)
D-80T-505-3N(A)
D-100S-199-3N
D-100S-250-3N(A)
D-100L-199-3N
D-100L-250-3N(A)
D-100L-270-3N(A)**
D-100L-300-3N(A)
D-80L-399-3N(A)
D-80L-450-3N(A)
D-80L-505-3N(A)
Capacity
GPH Recovery
at Degree Rise*
U.S. Imp.
Gal. Gal.
Nat.
BTU/Hr.
Input
LP
BTU/Hr.
Input
40°F 100°F 140°F
38
75
75
80
80
80
98
98
75
65
65
80
80
100
100
100
100
100
100
80
80
80
155,000
125,000
160,000
180,000
199,999
250,000
199,999
250,000
300,000
370,000
399,999
425,000
505,000
199,999
250,000
199,999
250,000
270,000
300,000
399,999
450,000
505,000
155,000
125,000
155,000
180,000
199,999
235,000
199,999
235,000
300,000
370,000
399,999
425,000
505,000
199,999
250,000
199,999
250,000
270,000
300,000
375,000
425,000
475,000
376
303
389
436
485
606
485
606
727
897
970
1030
1178
485
606
485
606
655
727
970
1091
1224
31
62
62
67
67
67
82
82
62
54
54
67
67
83
83
83
83
83
83
67
67
67
150
121
155
175
194
242
194
242
291
359
388
412
489
194
242
194
242
262
291
388
436
489
107
86
111
124
139
173
139
173
208
256
277
294
337
139
173
139
173
187
208
277
312
350
B
Jacket
Dia.
C
Vent
Dia.
in.
in.
in.
F
H
E
D
J
Front Floor Front Floor Floor
Hot to Gas Cold to Top to Top
of
Water Conn. Water
Water Water
Conn. Heater Conn. Conn.
Conn.
in.
in.
in.
in.
in.
in.
51
721/4
721/4
717/8
717/8
717/8
833/8
833/8
743/8
731/4
731/4
823/4
823/4
763/4
763/4
75
75
75
753/8
711/2
69
69
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
281/4
301/4
301/4
301/4
301/4
301/4
301/4
301/4
6
5
6
6
6
6
6
6
7
8
8
10
10
6
6
6
6
6
7
8
10
10
35
541/2
541/2
56
56
56
67
67
541/8
541/8
541/8
641/2
641/2
603/8
603/8
561/2
561/2
561/2
561/2
511/2
511/2
511/2
A
Top
Vent
Height
45/8
43/4
43/4
43/4
43/4
43/4
43/4
43/4
101/2
101/2
101/2
101/2
101/2
45/8
45/8
41/2
41/2
41/2
41/2
101/2
101/2
101/2
193/8
34
34
191/2
191/2
191/2
191/2
191/2
29
29
29
29
29
203/4
203/4
231/2
231/2
231/2
231/2
231/2
231/2
231/2
431/2
65
65
641/2
641/2
641/2
751/2
751/2
653/4
643/4
643/4
751/2
751/2
677/8
677/8
643/4
643/4
643/4
643/4
601/4
601/4
601/4
Liters
Nat.
kW/Hr.
Input
LP
kW/Hr.
Input
22°C
56°C
78°C
mm.
mm.
mm.
F
H
E
D
Front Floor Front Floor
Hot to Gas Cold to Top
of
Water Conn. Water
Conn. Heater
Conn.
mm. mm.
mm. mm.
144
284
284
303
303
303
371
371
284
246
246
303
303
379
379
379
379
379
379
303
303
303
45.4
36.6
46.8
52.7
58.6
73.2
58.6
73.2
87.9
108.4
117.2
124.5
148.0
58.6
73.2
58.6
73.2
79.0
87.9
117.2
131.8
148.0
45.4
36.6
45.4
52.7
58.6
68.9
58.6
68.9
87.9
108.4
117.2
124.5
148.0
58.6
73.2
58.6
73.2
79.0
87.9
109.9
124.6
139.2
1391
1147
1431
1650
1836
2294
1836
2294
2752
3395
3671
3899
4459
1836
2294
1836
2294
2479
2752
3671
4129
4633
556
458
572
662
734
916
734
916
1101
1359
1469
1559
1783
734
916
734
916
992
1101
1469
1650
1851
397
326
409
469
526
655
526
655
787
969
1048
1113
1276
526
655
526
655
708
787
1048
1181
1325
1295
1835
1835
1826
1826
1826
2118
2118
1889
1861
1861
2102
2102
1949
1949
1905
1905
1915
1905
1816
1753
1753
718
718
718
718
718
718
718
718
718
718
718
718
718
718
718
768
768
768
768
768
768
768
152
127
152
152
152
152
152
152
178
203
203
254
254
152
152
152
152
152
178
203
254
254
889
1384
1384
1422
1422
1422
1702
1702
1375
1375
1375
1638
1638
1534
1534
1435
1435
1435
1435
1308
1308
1308
Capacity
LPH Recovery
at Degree Rise*
(A) = ASME Code Available
(F) = Front Water Connection
(T) = Top Water Connection
** = Available in Natural Gas Only
+ = Fiberglass Insulation
For Propane (LP) Gas models
change suffix “N” to “X”.
220V/50Hz Available - Consult
factory.
A
B
Top Jacket
Vent
Dia.
Height
C
Vent
Dia.
117
121
121
121
121
121
121
267
267
267
267
267
267
114
114
114
114
114
114
267
267
267
492
864
864
495
495
495
495
495
737
737
737
737
737
527
527
597
597
597
597
597
597
597
1105
1651
1651
1638
1638
1638
1918
1918
1670
1645
1645
1918
1918
1724
1724
1645
1645
1645
1645
1530
1530
1530
–
671/8
671/8
661/4
661/4
661/4
771/4
771/4
–
–
–
–
–
70
70
67
67
67
67
–
–
–
11/2 (F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (F)
11/2 (F)
11/2 (F)
Approx.
Shipping
Relief
Weight
Gas Valve
(lbs.)
Conn. Open.
Dia. in. Std. ASME
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1
3/4
3/4
3/4
1(N)
3/4 (LP)
1(N)
3/4 (LP)
1
1
1
1
1
1
3/4
3/4
3/4
1(N)
3/4 (LP)
1(N)
3/4
1
3/4
3/4
3/4
1
1
1
1
1
1
3/4
3/4
1(N)
3/4 (LP)
1(N)
3/4 (LP)
1(N)
3/4 (LP)
438
520
520
540
540
540
610
610
590
665
665
750
750
667
667
725
725
725
725
800
800
800
–
–
–
–
–
590
–
690
645
720
720
800
800
–
702
–
765
765
765
835
835
835
Approx.
J
Shipping
Floor
Weight
Relief
to Top
(kg.)
Water Water Gas Valve
Conn. Conn. Conn. Open.
mm. Dia. mm. Std. ASME
mm.
–
1705
1705
1683
1683
1683
1962
1962
–
–
–
–
–
1778
1778
1702
1702
1702
1702
–
–
–
38 (F)
38 (T&F)
38 (T&F)
38 (T&F)
38 (T&F)
38 (T&F)
38 (T&F)
38 (T&F)
38 (F)
38 (F)
38 (F)
38 (F)
38 (F)
38 (T&F)
38 (T&F)
38 (T&F)
38 (F)
38 (F)
38 (F)
38 (F)
38 (F)
38 (F)
19
19
19
19
19
19
19
19
19
25(N)
19 (LP)
25
25(N)
19 (LP)
25(N)
19 (LP)
19
19
19
19
19
19
25(N)
19 (LP)
25(N)
19 (LP)
25(N)
19 (LP)
19
19
19
19
19
25
19
25
25
25
25
25
25
19
25
19
25
25
25
25
25
25
199
236
236
245
245
245
277
277
268
302
302
340
340
302
302
329
329
329
329
363
363
363
* Recoveries are based on Natural Gas Input and 80% Thermal Efficiency.
Low NOx models are not available for inputs over 399,999 BTU/Hr.
For Low NOx compliance, place an “E” following the BTU input identifier of the model number.
Example: D-75T-125E-3N
Amperage Draw = .5 for damper models/less than 4 for induced draft models.
Power Vent Kits – available for inputs from 125,000 to 505,000 BTU/Hr.
For 5 year models change suffix from "3" to "5".
–
–
–
–
–
268
–
313
393
327
327
363
363
–
318
–
347
347
347
379
379
379
Commercial Gas Water Heater
B
C
B
C
B
C
B
C
A
A
J
A
H
J
J
D
H
H
A
D
H
D
D
F
F
F
F
E
E
E
Model D-38T-155
Model D-75T-(125,160)
B
C
B
E
Model D-80T-(180,199,250)
Model D-100T-(199,250)
B
C
B
C
C
A
A
A
A
J
D
H
H
H
H
D
D
D
F
F
F
F
E
E
Model D-75T-300
E
Model D-65T-(370,399)
Model D-80T-(425,505)
B
C
B
C
A
J
A
H
H
D
D
F
E
Model D-100L-(199,250,270,300)
F
E
Model D-80L-(399,450,505)
TYPICAL APPLICATIONS
Optional Power Vent Kits – available for inputs
from 125,000 to 505,000 BTU/Hr.
BTU Input Range
Kit Number
125,000 to 290,000 BTU/Hr.:
239-81764-00
300,000 to 399,999 BTU/Hr.:
239-81766-00
425,000 to 505,000 BTU/Hr.:
239-82148-00
E
Model D-100S-(199,250)
Commercial Gas Water Heater
Sample Specification
The water heater shall be a Bradford White model with a rated storage capacity of not less than_______gallons (_______liters), a minimum gas input of
_______BTU/Hr. (_______ kW), a minimum recovery of _______GPH (_______ LPH). The tank shall be Vitraglas® lined and have a bolted hand hole cleanout.
A digital LCD display shall be integrated into the front control box, and the control shall be an adjustable electronic thermostat to any temperature up to 180ºF
(85°C) must have an automatic re-set Energy Cut-off (E.C.O), which shuts off all gas in an event of a overheat condition. The tank shall have
_______magnesium anode rods installed in separate tank head couplings. The heater shall have Non-CFC foam insulation, electronic ignition, and come
equipped with an ASME rated T&P relief valve, a cold water inlet Hydrojet® Sediment Reduction System, and a automatic flue damper (115V AC required). It
shall be design certified by CSA International for 180ºF (82ºC) application, either with or without a separate storage tank, and comply with state and local
codes and ordinances.
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All models are design certified by CSA
International (formerly AGA/CGA), ANSI standard Z-21.10.3, for up to 180°F (82°C) application as an Automatic Storage Heater, and an Automatic Circulating
Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring
or elaborate piping network. When equipped with a mixing valve, it will supply 180°F (82°C) sanitizing and lower temperature general purpose hot water
simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended).
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 ● Fax 215-641-1670 / Technical Support 800-334-3393 ● Fax 269-795-1089 ● Warranty 800-531-2111 ● Fax 269-795-1089
International: Telephone 215-641-9400 ● Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ● Fax 905-238-0105 / www.bradfordwhite.com
©2015, Bradford White Corporation. All rights reserved.
735-B-0315-A
Printed in U.S.A.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising