Innsbrook Lavatory Faucet with SELECTRONIC™ Technology

6055.204

6055.205

6055.202

6056.204

6056.205

6056.202

6057.205

6057.202

Product No.'s & Options

Specifications

How to Install

Electrical Hook-up

Maintenance

FAQ,s

Replacement Parts

1

2

2-3

4-6

7-8

9

10

Certified to comply with ASME A112.18.1M

© 2010 American Standard

M968498 Rev.1.5

NOTE TO INSTALLER: Please give this manual to the customer after installation.

To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.

customer's e-mail us at: [email protected]

For Parts, Service, Warranty or other Assistance,

please call

1-800-442-1902 (In Canada: 1-800-387-0369)

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

UNPACKING

All American Standard Faucets Are Water Tested At Our Factory.

Some Residual Water May Remain In The Faucet During Shipping.

1. Remove the fitting and loose items from the carton. The illustration below shows the fitting and all loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.

1. Selectronic Spout Assembly

2. Mounting Kit

3. Electrical Enclosure

4. Supply Hose

5a. DC Power Supply (for 6055 series)

5b. AC Power Supply (for 6056 series)

5c. 10 ft. Extension Wire (for 6057 series)

6. Circuit board

7. Mixing Valve ( optional must be ordered separately)

8. Key for vandal resistant aerator

PRODUCT No.s

6055.204

6055.205

6055.202

6056.204

6056.205

6056.202

6057.205

6057.202

5a

5b

5c

1

2

8

3

4

6

605XTMV

7

1 M 9 6 8 4 9 8 Rev. 1. 5

Fig. 1

155mm

(6-1/8)

175mm

(6-7/8)

162mm

(6-3/8)

Roughing-in Dimensions

124mm

(4-7/8)

38mm

(1-1/2)

MAX.

102mm

(4)

114mm

(4-1/2)

381mm

(15)

81mm

(3-3/16)

508mm

(20)

108mm

(4-1/4)

MOUNTING

SURFACE

125mm

(4-7/8)

1524mm

(60)

35mm

(1-3/8)

DIA.

3 HOLES

57mm

(2-1/4)

GENERAL DESCRIPTION:

Electronic faucet with proximity operation. Vandal resistant solid brass construction 4" center to center mounting.

Operates on DC (battery) or AC permanent power. In-line strainer for solenoid is integral. Single inlet 3/8 compression, built-in checks, and flexible stainless steel 15" reach inlet hose for spout connection.

3/8" COMP.

TOOLS REQUIRED; Fig. 2

1 Channel Locks

2 Adjustable Wrench

3 Plumbers' Putty or Caulking

4 Phillips Screwdriver

5 Flat Blade Screwdriver

6 Electric Drill & 1/4" Drill Bit

7 Tape Measure

INSTALLATION

INSTALL SPOUT ASSEMBLY;

Fig. 3

CAUTION Turn off hot and cold water supplies before beginning

1. Make sure PUTTY PLATE (1) is installed on

FAUCET BODY (2). Fig. 1a.

2. Insert WIRES (3), FLEX HOSE (4) and STUDS (5) through holes of mounting surface. Fig. 1a.

3. From under side of mounting surface install SPIN

NUTS (6) onto MOUNTING STUDS (5). Fig. 1b.

4. Align FAUCET (2) and hand tighten SPIN NUTS (6) to secure faucet to mounting surface.

Fig. 1b.

Fig. 2

3

Fig. 1a

Fig. 1b

2

4

3

5

4

5

1

7

10'

6

2

6

5

1

2

5

6

M 9 6 8 4 9 8 Rev. 1. 5

1. Determine location of ENCLOSURE (1). It must be located with-in the 14" (356mm) by 21" (533mm) shaded area shown in Figure 2 in order for electrical connections from the spout assembly to be made.

NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance between wall supply and ENCLOSURE (1) must be taken into consideration.

2. Remove 4 screws from COVER (2) and pull off

COVER (2). Hold the ENCLOSURE (1) in desired location and mark the four mounting hole locations as shown. Fig. 2.

3. The ENCLOSURE (1) works best if secured to a wall stud or cross brace within the wall, using the SCREWS

(3) supplied. If the ENCLOSURE (1) is to be installed on a tile or plaster wall the ANCHORS (4) and SCREWS

(3) should be used.

4. For installations on drywall or tiled walls; use

ANCHORS (4) and SCREWS (3) for securing

ENCLOSURE (1) to finished wall. Drill four 1/4" dia. holes a minimum of 1-3/4" deep. Insert the four

ANCHORS (4) flush with face of the finished wall.

Align the ENCLOSURE (1) and Install the MOUNTING

SCREWS (3). Tighten to secure ENCLOSURE (1) to mounting surface.

CONNECT SPOUT HOSE TO

ENCLOSURE; Fig. 3

1. Connect SUPPLY NUT (1) from spout assembly to nipple on top of ENCLOSURE (2). Tighten with adjustable wrench to make a water tight connection.

Fig. 3.

CONNECT WATER SUPPLY TO

ENCLOSURE AND WALL SUPPLY;

Fig. 4

NOTE; If using the optional Mixing Valve See Sheet

#M968808 for installation instructions.

1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on

ENCLOSURE (2).

2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to

FLEXIBLE SUPPLY HOSE (3). Tighten to make a water tight connection. Use two wrenches to tighten if necessary. Fig. 4.

3. Connect FLEXIBLE SUPPLY (3) directly to wall supply.

Connection on FLEXIBLE SUPPLY (3) is 3/8" compression. Use adjustable wrench to tighten connection. Do not over tighten. Fig. 4a.

Note: FLEXIBLE SUPPLY (3) measures 20" from the bottom of the ENCLOSURE (1) base. If additional supply length is required, installer must purchase parts separately.

Important: If FLEXIBLE SUPPLY (3) is too long, loop to avoid kinking.

3

Fig. 2

LAVATORY RIM OR

MOUNTING SURFACE

14"

(356mm)

SUPPLIES 1

4

WASTE

20"

(500mm)

21"

(mm)

MOUNTING HOLES

1524mm

(60)

3"

(76mm)

3

1

2

1

ENCLOSURE

MOUNTING

HOLES

2-3/4"

(71mm)

3-3/4"

(96mm)

NOTE: If using Mixing Valve (optional) See Sheet

#M968808 for installation instructions.

Fig. 3

1

Fig. 4

Fig. 4a

2

2 1

COLD WATER OR

TEMPERED

WALL SUPPLY

3

3

4

M 9 6 8 4 9 8 Rev. 1. 5

ELECTRICAL INSTALLATION

Fig. 1

5

1. Remove ENCLOSURE COVER (1). Fig. 1.

2. Feed the WIRE CONNECTORS (2) through the top of ENCLOSURE (5). Fig. 1a.

3. Remove GROMMET (4) from ENCLOSUR (5). Fig.1.

4. Feed the gray SENSOR WIRE (7) through

GROMMET (4), 4" from CONNECTOR. Fig. 1b & 1d

Insert gray SENSOR WIRE (7) into SPLIT PLUG (9).

Push SPLIT PLUG (9) into GROMMET (4) to seal.

Fig. 1d.

5. Insert GROMMET (4) back into ENCLOSURE (5).

Fig. 1c.

6. Install BATTERY (11) onto DC circuit board. Fig.1e.

Note: For BATTERY PACK installation see "Install

Battery" page 7.

7. Install CIRCUIT BOARD (3) into ENCLOSURE (5) with SENSOR WIRE (7) under BOARD. Fig. 1c.

8. Insert SENSOR WIRE CONNECTOR (8) into

CIRCUIT BOARD RECEPTOR (10). Fig. 1e.

9. Connect wires from SENSOR to SOLENOID VALVE

(6) (Red to +, Black to -). Fig. 1c.

10. Replace ENCLOSURE COVER (1). Tighten cover screws firmly.

Fig. 1a

Fig. 1d

4

Fig. 1e

9

7

11

8

4 1

Fig. 1b

4"

5

2

Fig. 1c

5

7

6

BLACK

7

4

4

RED

8

3

10

M 9 6 8 4 9 8 Rev. 1. 5

4

CAUTION Before opening ENCLOSURE disconnect AC power supply.

1. Remove ENCLOSURE COVER (1). Fig. 2.

2. Feed the WIRE CONNECTORS (2) through the top of ENCLOSURE (5). Fig. 2a.

3. Remove GROMMET (4) from ENCLOSUR (5). Fig. 2.

4. Feed the gray SENSOR WIRE (7) through

GROMMET (4), 4" from CONNECTOR. Fig. 2b. Insert gray SENSOR WIRE (7) into SPLIT PLUG (9). Push

SPLIT PLUG (9) into GROMMET (4) to seal. Fig. 2e.

5. Insert GROMMET (4) back into ENCLOSURE (5).

Fig. 2d.

6. Remove SPLIT PLUG (11) from POWER SUPPLY

GROMMET (12). Insert POWER CORD CONNECTOR

(13) through POWER SUPPLY GROMMET (12). Insert

POWER CORD (14) into SPLIT PLUG (11). Push

SPLIT PLUG (11) into POWER SUPPLY GROMMET

( 12) to seal. Fig. 2g.

7. Insert POWER SUPPLY CONNECTOR (13) into

RECEPTOR (15) on the CIRCUIT BOARD (3). Fig. 2c.

8. Install CIRCUIT BOARD (3) into ENCLOSURE (5) with SENSOR WIRE (7) under BOARD. Fig. 2d.

9. Insert SENSOR WIRE CONNECTOR (8) into

CIRCUIT BOARD RECEPTOR (10) slot. Fig. 2f.

10. Connect wires from SENSOR to SOLENOID

VALVE (6) (Red to +, Black to -). Fig. 2d.

11. Replace ENCLOSURE COVER (1). Tighten cover screws firmly.

Fig. 2g

Fig. 2

5

Fig. 2a

5

Fig. 2b

4

4"

Fig. 2c

Fig. 2e

13

POWER

SUPPLY

CORD 3

15

9 4

2

Fig. 2d

5

7

6

BLACK

7

4

7

Fig. 2f

8

10

14

13

11

12

5

1

4

RED

8

3

M 9 6 8 4 9 8 Rev. 1. 5

Fig. 3

Unit #1 Unit #2

TWO PIECE

GROMMET

1

Unit #3

1

4"

1

3

FOR AC-VERSION

(MULTI HOOK-UP); Fig. 3, 4

1. See AC Version Electrical Hook-up for first unit of the

Multi hook-up.

2. Remove ENCLOSURE COVERS from all

ENCLOSURES.

3. Remove SOLID BLACK INSERT(1) from right side of ENCLOSURE #1 and replace with gray 2-PIECE

GROMMET (3). Replace solid black inserts on Unit #2 with gray 2-PIECE GROMMET (3).

4. Take the 10 ft. EXTENSION (2) from Unit #2 and install into right side of Unit #1 and Left side of Unit #2 insealing wire into SPLIT PLUG (7) as shown in Fig. 4.

Push SPLIT PLUG (7) into GROMMET (8).

5. Insert CONNECTOR from 10 ft. EXTENSION (2) into

CIRCUIT BOARD RECEPTOR (4) top of Unit #1 as shown in Fig. 3.

6. Insert other end of 8 ft. EXTENSION into LOWER U

GROMMET (5) of Unit #2 (approximately 4" from connector). Fig. 3. Push SPLIT PLUG (7) into

GROMMET (8) to seal.

7. Insert connector of 10 ft. EXTENSION into lower receptor as shown in Fig. 3 on CIRCUIT BOARD (6) of

Unit #2.

8. Feed gray sensor wire 9 from Unit #2 through upper

U GROMMET (10) of Unit #2 ENCLOSURE 4" from connector. Fig. 3. Insert wire into SPLIT PLUG (7).

Push SPLIT PLUG (7) into GROMMET (8) to seal. Fig. 4.

9. Insert GROMMET (2) back into ENCLOSURE. Fig. 4a.

10. Reinstall Circuit Board (3) into Enclosure with all wires under Board. Fig. 4a.

11. Connect Unit #2 Red and Black Sensor wires To #2 solenoid valve (Red to +, Black to -). Fig. 4a.

12. Repeat Steps 3 through 11 for remaining Units in

Multi Hook-up.

6

Fig. 4

TWO PIECE

GROMMET

7

8

2

Feed the gray 8 ft. EXTENSION (2) through ROUND

GROMMETS (3) and U GROMMETS (5) as illustrated above.

Fig. 4a

1

BLACK

2

RED

3

M 9 6 8 4 9 8 Rev. 1. 5

MAINTENANCE

HAND WASH SENSOR OPERATION

Fig. 1

When the Sensor detects a user, the water immediately starts to flow. Water flow will stop Two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for 59 seconds. The water will stay off until the blockage is removed from the detection zone.

Detection Zone: 2" - 10" (50mm - 250mm)

Default: Set at Factory 6" (150mm)

Fig 1

5

10

4

6

3

HOW TO CHANGE SENSOR

RANGE; (Factory set at 6") Fig. 2

1. Setting the Detection Zone (Distance):

Remove cover from ENCLOSURE. Disconnect GRAY

SENSOR WIRE (1) from circuit board, then reconnect.

2. While the SENSOR CONTROL LED (2) is blinking slowly, place your hand 1 - 2 in. (30-50mm) in front of the sensor. Fig. 2a.

3. When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. 2a.

4. Once the SENSOR CONTROL LED (2) begins to blink again, remove your hand from the detection zone.

When the flashing stops, the detection distance is set.

Fig. 2

Fig. 2a

1" - 2" (30mm - 50mm)

2

BLINKING

LED

HOW TO INSTALL AND CHANGE

BATTERY; Fig. 3

1. To install New BATTERY (1) align and press down

BATTERY (1) (contacts facing downward) into position until tabs lock into place.

To remove the BATTERY (1) spread the two tabs on the HOLDER (2) with your thumbs . The BATTERY (1) will release.

2. Remove the OLD BATTERY (1).

3. Install NEW BATTERY (1) (contacts facing downward) into HOLDER (2) and press down into position until tabs lock into place.

Fig.3

7

Fig. 3

2

BLINKING LED

1

2

1

BATTERY HOLDER

LOCKING TABS

1

UP TO 10" (250mm)

M 9 6 8 4 9 8 Rev. 1. 5

Fig.4

CAUTION Before opening ENCLOSURE disconnect AC power supply.

1. Remove ENCLOSURE COVER.

2. Close SUPPLY STOP (5) with 4mm Hex wrench.

Note: Keep water flowing out of faucet while shutting off.

3. Pull off Red (1) and Black (2) CONNECTORS from

SOLENOID VALVE (3).

4. Unthread STRAINER (4) using a 7/16" socket.

5. Pull out the STRAINER (4) and clean with an old toothbrush. Rinse thoroughly with water.

6. Install the STRAINER (4) back in its place and tighten with a 7/16" socket.

Caution: do not over tighten strainer.

Note: It is recommended to clean strainer every 6 months.

7. Replace ENCLOSURE COVER. Tighten cover screws firmly.

HOW TO CLEAN AND REMOVE

THE AERATOR; Fig. 5

1. Remove AERATOR HOUSING (1) with KEY supplied with faucet.

3. Remove AERATOR (2) from HOUSING (1).

2. Clean the AERATOR SCREENS (3) with a old tooth brush to remove dirt.

4. Rinse Clean with water. Reassemble and install into spout end. Be sure black seal washer is in place.

6

GENERAL CLEANING; Fig. 6

1. For general cleaning use a damp, soft cloth to clean the spout and the sensor.

2. For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth.

CAUTION

Do not scratch the sensor when cleaning.

Avoid using anything that may scratch the spout

surface. Never use polishing power, detergent or a nylon scrub brush. They will damage the surface of the spout or Sensor.

2

1

5

Fig.5

Fig.6

3

4

CLEAN

SCREENS

4

1

3

2

8 M 9 6 8 4 9 8 Rev. 1. 5

FAQ'S

Q: How will I know if battery needs to be replaced?

A: Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.

Q: Why has the flow rate of the faucet reduced significantly?

A: Check and clean aerator and strainer.

Q: There is no flow out of faucet when I'm in the sensor range?

A: Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1800-442-1902.

Q: Why does the faucet operate the opposite of expected-Turns On when not in sensor range, but turns off when in sensor range?

A: Sensor wires to solenoid are reversed. Black to -

& Red to + is correct.

Q: What is the normal operating pressure range?

A: Faucet will operate with supply pressures ranging from 20-80 psi.

9

M 9 6 8 4 9 8 Rev. 1. 5

M922286-YYY0A

0.35 GPM AERATOR

(6055.204, 6056.204)

M922887-YYY0A

1.5 GPM AERATOR

066508-YYY0A

0.5 GPM AERATOR

M962409-0070A

SENSOR KIT

M964155-0070A

SENSOR KIT FOR

(6055.204, 6056.204)

INNSBROOK with

SELECTRONIC

LAVATORY FAUCETS

PRODUCT NUMBERS

6055.204

6055.205

6055.202

6056.204

6056.205

6056.202

6057.205

6057.202

A923654-0070A

BATTERY 6VCR-P2

A923672-0070A

FAUCET SUPPLY

HOSE

A913202-0070A

WASHER

044912-0070A

MOUNTING NUT

M923115-0070A

PUTTY PLATE

M950250-0070A

DC SOLENOID

VALVE ASSEMBLY

M950251-0070A

AC SOLENOID

VALVE ASSEMBLY

A924162-0070A

SUPPLY HOSE

M962387-0070A

MOUNTING SCREW KIT

A918462-0070A

SOLENOID SCREWS

M962389-0070A

SOLENOID & SCREWS

A950507-0070A

FILTER

A922265-0070A

10 ft. MULTI EXTENSION WIRE

(for 6057 series only)

A950509-0070A

SUPPLY STOP

Replace the "YYY" with appropriate finish code

CHROME 002 M950169-0070A

POWER SUPPLY

A950487-0070A

CIRCUIT BOARD DC

A950489-0070A

CIRCUIT BOARD

AC & MULTI AC

A922251-0070A

SOLID GROMMET

A922267-0070A

ROUND GROMMET

A922272-0070A

U GROMMET

A922290-0070A

POWER SUPPLY

GROMMET

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays 8:00 a.m. to 8:00 p.m. EST

IN MEXICO 01-800-839-1200

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc.

© American Standard Inc. 2005

M 9 6 8 4 9 8 Rev. 1. 5

10

M 9 6 8 4 9 8 Rev. 1. 5

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What tools are needed for installation?
Channel Locks, Adjustable Wrench, Plumbers Putty or Caulking, Phillips Screwdriver, Flat Blade Screwdriver, Electric Drill & 1/4" Drill Bit, and Tape Measure.
What are the mounting surface dimensions?
The mounting surface dimensions are: 175mm (6-7/8) by 162mm (6-3/8).
What is the maximum diameter of the mounting holes?
The maximum diameter of the mounting holes is 35mm (1-3/8).
What is the length of the flexible supply hose?
The length of the flexible supply hose is 20 inches from the bottom of the enclosure base.
How do you replace the battery?
Remove the enclosure cover, locate the battery compartment, remove the old battery, and install the new battery.
How do you connect multiple units in a multi hook-up?
Remove the solid black insert from the right side of the first enclosure and replace it with the two-piece grommet. Install the 10ft extension into the right side of the first unit and the left side of the second unit. Connect the extension to the circuit board receptor and feed the sensor wire through the upper U grommet. Repeat for additional units.
Download PDF