Datasheet | Daikin BRC1D517 Technical data
Add to my manuals18 Pages
Daikin BRC1D517 is an advanced wireless controller that offers smart and convenient control over your home's climate, allowing you to adjust settings and monitor energy usage right at your fingertips. With its intuitive interface and compatibility with a range of Daikin air conditioning systems, you can effortlessly manage your comfort and efficiency.
advertisement
technical data
FDYMP-L7
Concealed Ceiling Unit
Split
Sky Air
Split - Sky Air
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
Specifications are subject to change without prior notice.
Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe N.V. is participating in the EUROVENT Certification Programme.
Products are as listed in the EUROVENT
Directory of Certified Products.
Zandvoordestraat 300
B - 8400 Ostend Belgium
Internet: http://www.daikineurope.com
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
TABLE OF CONTENTS
FDYMP-L
1
2
5
6
3
4
11
12
9
10
7
8
Features
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Nominal capacity, capacity steps and nominal input
Technical specifications
Dimensional drawings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping diagrams
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring diagrams
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound level
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound level data
Sound pressure spectrum
Sound power spectrum
Fan characteristics
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional accessories
Control systems
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Center of gravity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety device settings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
15
13
14
11
12
2
3
8
9
6
7
* For capacity tables, please refer to part II: outdoor units
•
Split - Sky Air
•
Indoor Units 1
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
1 Features
1
1 + Lightweight and compact: the depth of the unit is just 279mm for all capacity sizes.
+ Both discharge and suction ducts can be easily connected via flanges on the unit.
+ The air filter is easily accessible from underneath, even after the installation of the ducts.
+ Silent in operation both indoors and outdoors: sound pressure for the indoor units as low as 37dB(A)
+ Numerous optional control facilities
2
1
Optional
8 q x 7
6 ! 2 6 4
2 steps
•
Split - Sky Air
•
Indoor Units
2
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
Specifications
NOMINAL CAPACITY and NOMINAL INPUT
For indoor units only:
INDOOR UNITS
NOMINAL INPUT Cooling
Heating
For combination indoor + outdoor units (air cooled):
INDOOR UNITS
OUTDOOR UNITS
NOMINAL CAPACITY (3)
NOMINAL INPUT
EER
ENERGY LABEL
ANNUAL ENERGY
CONSUMPTION
Cooling
Cooling
Cooling
Cooling
For combination indoor + outdoor units (air cooled):
INDOOR UNITS
OUTDOOR UNITS
NOMINAL CAPACITY (3) Cooling
NOMINAL INPUT
Heating
Cooling
Heating
EER
COP
ENERGY LABEL
ANNUAL ENERGY
CONSUMPTION
Cooling
Heating
Cooling
For combination indoor + outdoor units (air cooled):
INDOOR UNITS
OUTDOOR UNITS
NOMINAL CAPACITY (3) Cooling
NOMINAL INPUT
Heating
Cooling
Heating
EER
COP
ENERGY LABEL
ANNUAL ENERGY
CONSUMPTION
Cooling
Heating
Cooling kW kW kW kW kWh kW kW kW kW kWh kW kW kW kW kWh
FDYMP71L7V1
-
-
FDYMP100L7V1
-
-
FDYMP125L7V1
-
-
FDYMP71L7V1
RP71L7V1/W1-RP71B7T1
7.10
2.60/2.66
2.67/2.73
D/D
1,330/1,300
FDYMP100L7V1
RP100L7V1/W1-RP100B7T1
10.00
3.75/3.72
2.66/2.69
D/D
1,875/1,860
FDYMP125L7V1
RP125L7W1-RP125B7T1
12.20
4.62
2.64
D/D
2.310
FDYMP71L7V1
RYP71L7V1/W1
7.10
8.00
2.61/2.55
2.48/2.43
2.72/2.78
3.21/3.29
D/D
C/C
1,305/1,275
FDYMP71L7V1
RYEP71L7V1/W1
7.10
8.00
2.70/2.63
2.57/2.50
2.63/2.70
3.11/3.20
D/D
D/C
1,350/1,315
FDYMP100L7V1
RYP100L7V1/W1
10.00
11.00
3.68/3.65
3.75/3.72
2.72/2.74
2.93/2.96
D/D
D/D
1,840/1,825
FDYMP100L7V1
RYEP100L7V1/W1
10.00
11.00
3.69/3.79
3.79/3.89
2.71/2.64
2.90/2.83
D/D
D/D
1,845/1,895
FDYMP125L7V1
RYP125L7W1
12.20
14.50
4.55
4.34
2.68
3.34
D
C
2.275
FDYMP125L7V1
RYEP125L7W1
12.20
14.50
4.55
4.34
2.68
3.34
D
C
2.275
1
2
•
Split - Sky Air
•
Indoor Units 3
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
2 Specifications
1
2
TECHNICAL SPECIFICATIONS
For indoor units only:
INDOOR UNITS
DIMENSIONS Unit
WEIGHT
MATERIAL
SOUND LEVEL
FAN
HEAT EXCHANGER
H
W
D
Unit
Unit
Sound pressure
(cooling/heating) (1)
Sound power
(cooling only) (2)
Air flow rate
(cooling/heating)
Speed
Type
Qty x motor output
External static pressure (H-L)
Drive
Type
Rows x stages x fin pitch
Face area high low high high low steps
AIR FILTER
TEMPERATURE CONTROL
PIPING CONNECTIONS liquid gas drain drain
INSULATION MATERIAL Heat insulation
Sound absorbing insulation
For outdoor units Pair application
Twin application
W
Pa mm mm mm kg dB(A) dB(A) dB(A) m 3 m 3
/min
/min mm m 2 mm mm mm mm
FDYMP71L7V1
37/37
33/33
63
19/19
14/14
1 x 130
φ 15.9
I.D.
φ 25
O.D.
φ 32
FDYMP100L7V1
279
987
750
38.1
Painted galvanised steel plate
39/39
34/34
65
0.226
27/27
20/20
3 steps
Sirocco fan
1 x 155
100 - 50
Direct drive
Fin rhombus type, J7 Hi-XA tube
3 x 14 x 1.75
Resin net
Computerised control
φ 9.52
φ 19.1
I.D.
φ 25
O.D.
φ 32
Both liquid and gas pipes
Felt
See chapter RP-L7/B7/RYP-L/RYEP-L7
See chapter RP-L7/B7/RYP-L7/RYEP-L7
FDYMP125L7V1
1,387
48.6
41/41
35/35
66
35/35
24/24
1 x 225
0.344
I.D.
O.D.
φ
φ
25
32
4
•
Split - Sky Air
•
Indoor Units
1
2
3
4
5
6
7
2
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
Specifications
ELECTRICAL SPECIFICATIONS
For indoor units only:
CURRENT Nominal running current
Max. running current cooling/heating A cooling/heating A
For combination indoor units + outdoor units:
CURRENT Nominal running current
Max. running current
Starting current cooling cooling cooling
A
A
A
For combination indoor units + outdoor units:
CURRENT Nominal running current
Max. running current
Starting current cooling/heating A cooling/heating A cooling/heating A
For combination indoor units + outdoor units:
CURRENT Nominal running current
Max. running current
Starting current cooling/heating A cooling/heating A cooling/heating A
For indoor units only:
POWER SUPPLY
NOMINAL DISTRIBUTION
SYSTEM VOLTAGE
Phase
Frequency
Voltage
Hz
V
FDYMP71L7V1
FDYMP71L7V1
RP71L7V1/W1-RP71B7T1
FDYMP71L7V1
RYP71L7V1/W1
FDYMP71L7V1
RYEP71L7V1/W1
FDYMP71L7V1
V1
1 ∼
50
230
FDYMP100L7V1
See chapter RP-L7/B7/RYP-L7/RYEP-L7
See chapter RP-L7/B7/RYP-L7/RYEP-L7
FDYMP100L7V1
RP100L7V1/W1-RP100B7T1
See chapter RP-L7/B7
See chapter RP-L7/B7
See chapter RP-L7/B7
FDYMP100L7V1
RYP100L7V1/W1
See chapter RYP-L7
See chapter RYP-L7
See chapter RYP-L7
FDYMP100L7V1
RYEP100L7V1/W1
See chapter RYEP-L7
See chapter RYEP-L7
See chapter RYEP-L7
FDYMP100L7V1
V1
1 ∼
50
230
FDYMP125L7V1
FDYMP125L7V1
RP125L7W1-RP125B7T1
FDYMP125L7V1
RYP125L7W1
FDYMP125L7V1
RYEP125L7W1
FDYMP125L7V1
V1
1 ∼
50
230
3TW25041-1
3TW25051-1
3TW25061-1
1
2
NOTES
Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB * outdoor temperature 35°CDB * refrigerant piping length: 7.5m * level difference: 0m.
Nominal heating capacities are based on: indoor temperature: 20°CDB * outdoor temperature: 7°CDB/6°CWB * refrigerant piping length: 7.5m * level difference 0m.
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
The sound pressure level is measured via a microphone at 1.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter.
The sound power level is an absolute value indicating the ’’power’’ which a sound source generates.
Energy label: scale from A (most efficient) to G (less efficient).
Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions).
•
Split - Sky Air
•
Indoor Units 5
3
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
Dimensional drawings
1
3
FDYMP71-100L7
1 Liquid pipe connection J9.52 Flare connection
2 Gas pipe connectionJ A Flare connection
3 Remote control wiring connection
4 Power supply connection
5 Drain pipe connection VP25 (O.D. J 32, I.D. J 25)
6 Air filter
7 Air suction side
8 Air discharge side
9 Name plate view B
960 (Suspension position) view A
Suspension bolt
6
Notes:
1. Refer to ’outlook drawing for installing optional accessories’ when installing optional accessories.
2. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the ’filter installation method’ drawing)
300 mm or more
(Service space)
Model
FDYMP71L7V1
FDYMP100L7V1
A
15.90
19.10
FDYMP125L7
1 Liquid pipe connection J9.52 Flare connection
2 Gas pipe connection J19.10 Flare connection
3 Remote control wiring connection
4 Power supply connection
5 Drain pipe connection VP25 (O.D. J32, I.D. J25)
6 Air filter
7 Air suction side
8 Air discharge side
9 Name plate
1360 (Suspension position) view A
3TW25044-1
Suspension bolt view B
•
Split - Sky Air
•
Indoor Units
(Service space)
Notes:
1. Refer to ’outlook drawing for installing optional accessories’ when installing optional accessories.
2. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the ’filter installation method’ drawing)
2TW25064-1
4
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
Piping diagrams
FDYMP71-125L7
Heat exchanger
Filter
Liquid pipe connection port
Gas pipe connection port
Cooling
Heating
Refrigerant flow
Refrigerant pipe connection port diameters
FDYMP71L7V1
Model
FDYMP100L7V1
FDYMP125L7V1
Gas
J 15.9
J 19.1
Liquid
J 9.52
J 9.52
1
4
O
Check valve
L
Flare connection
M
Screw connection
N
Flange connection Z Pinched pipe
P
Spinned pipe
3TW25045-1
•
Split - Sky Air
•
Indoor Units 7
5
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
Wiring diagrams
1
5
FDYMP71
∼
125L7
Outdoor Indoor
Notes
1. When using the central remote control, see manual for connection to the unit.
2. The infrared remote control model varies according to the combination system.
See technical data and catalogs before connecting.
Wired remote control
Terminals for operation indicator
Details of wired remote control
(optional accessory) g Field wiring D Terminal a : Connector c b
: Wire clamp
: Protective earth (screw)
Colours
BLK: Black/ PPL: purple/ BLU: Blue/
WHT: White/ RED: Red/ GRN: green/
GRY: grey/ YLW:Yellow
A1P
T1R
C1R
F1T
HAP
M1F
R1T
R2T
Printed circuit board
Power supply transformer (transformer 220-240V/
218V)
Capacitor (fan)
Thermal fuse (152°C) (M1F embedded)
Light emitting diode (service monitor green)
Motor (fan)
Thermistor (air)
Thermistor (coil)
RyF1 ∼ 3 Magnetic relay (fan)
SS1
X1M
X2M
RC
Selector switch (emergency)
Terminal strip
Terminal strip
Signal receiver circuit
TC Signal transmission circuit
Group control jumper
J1 Jumper for ’’Master/slave’’ determination BS7
BS11
BS12
BS14
Wired remote control
BS1
BS2
On/Off button
Timer mode start/stop button
BS3,BS8 Programming time button
BS4,BS9 Temperature setting button
BS6 Operation mode selector button
Timer on/off button
Fan speed control button
Inspection/test operation button
Filter sign reset button
Switch box
Adapter for wiring
LED1
LCD
Light emitting diode (service monitor red)
Liquid crystal display (LCD)
SS1 Selector switch (main/sub)
Adapter for wiring
RyC,RyF Magnetic relay
Connector for optional parts
X33A
X35A
X40A
Connector (adapter for wiring)
Connector (group control adapter)
Connector (remote ON/OFF forced OFF)
Cautions for servicing
With the power on, troubles can be monitored on the remote controller or the LED on the PC board of the indoor unit.
Troubleshooting with the display on the liquid crystal of the remote controller.
When the operation stops due to trouble, the operation lamp flashes, ’’b’’ and the error codes are indicated on the liquid crystal display. In this case, diagnose the fault contents by refering to the table on the right. In case of group control, the unit number is displayed so that the indoor unit with the trouble can be recognized (see note 2).
Press the INSPECTION/TEST OPERATION button ’’b’’ is displayed and ’’O’’ flashes.
Press the PROGRAMMING TIME button and find the unit number which stopped due to trouble.
Number of beeps:
3 short beeps ... Perform all the following operations
1 short beep ... Perform j
1 long beep ... No trouble
3
Press the operation mode selector button and upper figure of the error code flashes.
Continue pressing the PROGRAMMING TIME button until it makes 2 short beeps and find the upper code.
Press the OPERATION SELECTOR button and lower figure of the error code flashes.
Continue pressing the PROGRAMMING TIME button until it makes a long beep and find the lower code. A long beep indicates the error code.
Error codes
Malfunction
A1 Indoor unit’s PC board
A6 Indoor fan motor overloaded, overcurrent or locked
AJ Type set error (indoor unit)
Remarks
Capacity data is wrongly preset or there is nothing programmed in the data hold IC.
C4 Sensor for heat exchanger temperature (indoor)
C9 Sensor for suction air temperature (indoor)
CJ Sensor for remote controller The remote controller thermistor does not work, but the system thermo run is possible.
E0 Action of safety device (outdoor unit)
E1 Outdoor unit’s PC board
E3 Abnormal high pressure (outdoor unit)
E4 Abnormal low pressure (outdoor unit)
E9 Electronic expansion valve (outdoor unit)
F3 Abnormal discharge pipe temperature (outdoor unit)
H3 High pressure switch defect (outdoor unit)
H4 Low pressure switch defect (outdoor unit)
H9 Outdoor air thermistor
J3 Discharge pipe thermistor (outdoor unit)
J5 Suction pipe thermistor (outdoor unit)
J6 Heat exchanger thermistor (outdoor unit)
PJ Type set error (outdoor unit)
(See note 3)
(See note 3)
Capacity data is wrongly preset or there is nothing programmed in the data hold IC.
U0 Abnormal suction pipe temperature (outdoor unit)
U1 Reverse phase Reverse 2 of the 3 lead wires
U4 Transmission error (indoor unit - outdoor unit) Transmission indoor - outdoor is improper
U5 Transmission error (indoor unit - remote controller)
UF Miss wiring
Transmission indoor-remote contr. Is improper if group control: check ’master-slave jumper’.
Field wiring is not correct
For the white error codes on a black background, be sure to check and repair, though system may be operated without displaying ’’b.
Notes:
1. Press the INSPECTION / TEST OPERATION button.
’’b starts flashing.
2. Keep down the ON/OFF button for 5 seconds or longer in the inspection mode, and the above trouble history disappears, after the trouble code goes on and off twice, followed by the code ’’00’’
(normal). The display changes from the inspection mode to the normal mode.
3. Equipment operation in response to errors will vary according to the model.
Troubleshooting with the LED on the indoor PC board.
The following checking can be made with the service monitor LED (green) (normal when flashing).
p: LED on s: LED off q: LED flashing
Microcomputer normal monitor
HAP q
Description p s
Normal -> Outdoor unit
Indoor PC board error (see note)
Power supply trouble or PC board error (see note)
NOTE:
Cut off the power and wait for 5 seconds or longer.
Turn on the power again and see if the LED is the same state.
2TW25046-1A
8
•
Split - Sky Air
•
Indoor Units
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
6 Sound level
6-1
Sound level data
Sound pressure level
Model
230V, 50Hz
Cooling/Heating
FDYMP71L7V1
FDYMP100L7V1
FDYMP125L7V1
High
37/37
39/39
41/41
Low
33/33
34/34
35/35
Measuring location
Suction
Location of microphone
Unit Discharge
Microphone
6-2
Sound pressure spectrum
FDYMP71L7 FDYMP100L7
Sound power level (H)
(cooling)
1
6
6-1
63
65
66
Octave band center frequency (Hz)
3TW25047-1
Octave band center frequency (Hz)
3TW25057-1
FDYMP125L7
Octave band center frequency (Hz)
3TW25067-1
•
Split - Sky Air
•
Indoor Units
Legend
High speed
Low speed
3
4
1
2
NOTES
Data is valid at free field condition
Data is valid at low ESP operation condition. (50 Pa AT 230V) dBA = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20µPa
9
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
1
6
6-3
6 Sound level
6-3
Sound power spectrum
FDYMP71L7 FDYMP100L7
3TW25047-2
Octave band center frequency (Hz)
FDYMP125L7
3TW25057-2
Octave band center frequency (Hz)
1
2
3
NOTES
Data is valid at low ESP operation high tap condition. (50Pa at 230V) dB(A) = A-weighted sound power level (A-scale according to IEC)
Measured in duct according to ISO 9614
10
3TW25067-2
Octave band center frequency (Hz)
•
Split - Sky Air
•
Indoor Units
7
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
Fan characteristics
FDYMP71L7
Fan curve 71 class motor
FDYMP100L7
Air flow (m 3 /min)
Fan curve 100 class motor
3TW25048-1
1
7
FDYMP125L7
Air flow (m 3 /min)
Fan curve 125 class motor
3TW25058-1
Air flow (m 3 /min)
•
Split - Sky Air
•
Indoor Units
3TW25068-1
11
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
8 Accessories
8-1
Optional accessories
1
8
8-1
Item
Remote control
Adapter for wiring (interlock for fresh air intake fan)
Adaptor for external ON/OFF and monitoring
Wired type
71-100-125 Class
BRC1D517
KRP1B59
KRP4A51
Wiring adapte (electrical heater and hour meter EKRP1B2
Installation box
Remote ON/OFF, forced OFF
KRP1B947A
EKR0R0
3TW25049-4B
* Electrical heater and humidifier are field supply. The electrical heater should be installed in the discharge duct.
Wire specifications
Connector (White) connect to indoor PCB (X40A)
AWG24 0.22mm
2 White
White connect to on/off switch
Operating method
ON*
Switch
OFF
ON
Remote control
OFF
ON
Standard setting:
’forced off’
OFF
ON
Alternative setting: ’on/off’
OFF
* Input ’ON’ = closed contact.
12
Forced off
Input ’on’ stops operation + disables control
Input ’off’ enables control
On/off operation
Input off → on: starts operation, remote control is still enabled.
Input on → off: stops operation, remote control is still enabled.
Selection of ’FORCED OFF’ and ’ON/OFF’ operation
Forced off
On/off operation
Setting Mode NO
12 (22)
•
Split - Sky Air
•
Indoor Units
First code NO
1
Second code NO
01
02
4TW23941-1
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
9 Control systems
9-1
Wired remote control
BRC1D527
5 x 10 (Round end slit)
5 x 7 (Round end slit) HoleJ5
6.5 x 9 (Round end slit)
Cover closed
1
9
9-1
3TW23651-2
Cover open
•
Split - Sky Air
•
Indoor Units 13
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
10 Center of gravity
1
10 FDYMP71-125L7
71 - 100 Class
125 Class
Model A
920
1320
B
420
600
4TW25049-3
11 Safety device settings
FDYMP71-125L7
FDYMP
Model
3TW21009-2C
Safety devices
Fan motor thermal fuse (°C)
71
152±2
100
152±2
125
152±2
14
•
Split - Sky Air
•
Indoor Units
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
12 Installation instructions
Preparations before installing Selecting installation site Drain pipe work
Names and functions of parts How to clean the air filter
Service of switch box
Refrigerant piping work Indoor unit installation
Drain pipe work Computerised control (forced OFF and ON/OFF operation)
1TW25049-2
•
Split - Sky Air
•
Indoor Units
1
12
•
Concealed Ceiling Unit
•
R-407C
•
FDYMP71-125L7V1/W1
12 Installation instructions
Filter fixing plate
Filter
Detail A
Scale 1/1
Only for 125 class
Only for 71 & 100 class
Only for 125 class
1
2
NOTES
Filter must slide in the filter fixing plates (see detail A)
Filter holding plate must be mounted correct (see detail B)
Filter holding plate
Detail B
Scale 1/1
3TW25044-2
16
•
Split - Sky Air
•
Indoor Units
advertisement