technical data

FDYMP-L7

Concealed Ceiling Unit

Split

Sky Air

Split - Sky Air

ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment

Daikin Europe N.V. is approved by LRQA for its Quality

Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

Specifications are subject to change without prior notice.

Daikin units comply with the European regulations that guarantee the safety of the product.

Daikin Europe N.V. is participating in the EUROVENT Certification Programme.

Products are as listed in the EUROVENT

Directory of Certified Products.

Zandvoordestraat 300

B - 8400 Ostend Belgium

Internet: http://www.daikineurope.com

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

TABLE OF CONTENTS

FDYMP-L

1

2

5

6

3

4

11

12

9

10

7

8

Features

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nominal capacity, capacity steps and nominal input

Technical specifications

Dimensional drawings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Piping diagrams

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wiring diagrams

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sound level

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sound level data

Sound pressure spectrum

Sound power spectrum

Fan characteristics

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Accessories

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Optional accessories

Control systems

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Center of gravity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety device settings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

15

13

14

11

12

2

3

8

9

6

7

* For capacity tables, please refer to part II: outdoor units

Split - Sky Air

Indoor Units 1

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

1 Features

1

1 + Lightweight and compact: the depth of the unit is just 279mm for all capacity sizes.

+ Both discharge and suction ducts can be easily connected via flanges on the unit.

+ The air filter is easily accessible from underneath, even after the installation of the ducts.

+ Silent in operation both indoors and outdoors: sound pressure for the indoor units as low as 37dB(A)

+ Numerous optional control facilities

2

1

Optional

8 q x 7

6 ! 2 6 4

2 steps

Split - Sky Air

Indoor Units

2

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

Specifications

NOMINAL CAPACITY and NOMINAL INPUT

For indoor units only:

INDOOR UNITS

NOMINAL INPUT Cooling

Heating

For combination indoor + outdoor units (air cooled):

INDOOR UNITS

OUTDOOR UNITS

NOMINAL CAPACITY (3)

NOMINAL INPUT

EER

ENERGY LABEL

ANNUAL ENERGY

CONSUMPTION

Cooling

Cooling

Cooling

Cooling

For combination indoor + outdoor units (air cooled):

INDOOR UNITS

OUTDOOR UNITS

NOMINAL CAPACITY (3) Cooling

NOMINAL INPUT

Heating

Cooling

Heating

EER

COP

ENERGY LABEL

ANNUAL ENERGY

CONSUMPTION

Cooling

Heating

Cooling

For combination indoor + outdoor units (air cooled):

INDOOR UNITS

OUTDOOR UNITS

NOMINAL CAPACITY (3) Cooling

NOMINAL INPUT

Heating

Cooling

Heating

EER

COP

ENERGY LABEL

ANNUAL ENERGY

CONSUMPTION

Cooling

Heating

Cooling kW kW kW kW kWh kW kW kW kW kWh kW kW kW kW kWh

FDYMP71L7V1

-

-

FDYMP100L7V1

-

-

FDYMP125L7V1

-

-

FDYMP71L7V1

RP71L7V1/W1-RP71B7T1

7.10

2.60/2.66

2.67/2.73

D/D

1,330/1,300

FDYMP100L7V1

RP100L7V1/W1-RP100B7T1

10.00

3.75/3.72

2.66/2.69

D/D

1,875/1,860

FDYMP125L7V1

RP125L7W1-RP125B7T1

12.20

4.62

2.64

D/D

2.310

FDYMP71L7V1

RYP71L7V1/W1

7.10

8.00

2.61/2.55

2.48/2.43

2.72/2.78

3.21/3.29

D/D

C/C

1,305/1,275

FDYMP71L7V1

RYEP71L7V1/W1

7.10

8.00

2.70/2.63

2.57/2.50

2.63/2.70

3.11/3.20

D/D

D/C

1,350/1,315

FDYMP100L7V1

RYP100L7V1/W1

10.00

11.00

3.68/3.65

3.75/3.72

2.72/2.74

2.93/2.96

D/D

D/D

1,840/1,825

FDYMP100L7V1

RYEP100L7V1/W1

10.00

11.00

3.69/3.79

3.79/3.89

2.71/2.64

2.90/2.83

D/D

D/D

1,845/1,895

FDYMP125L7V1

RYP125L7W1

12.20

14.50

4.55

4.34

2.68

3.34

D

C

2.275

FDYMP125L7V1

RYEP125L7W1

12.20

14.50

4.55

4.34

2.68

3.34

D

C

2.275

1

2

Split - Sky Air

Indoor Units 3

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

2 Specifications

1

2

TECHNICAL SPECIFICATIONS

For indoor units only:

INDOOR UNITS

DIMENSIONS Unit

WEIGHT

MATERIAL

SOUND LEVEL

FAN

HEAT EXCHANGER

H

W

D

Unit

Unit

Sound pressure

(cooling/heating) (1)

Sound power

(cooling only) (2)

Air flow rate

(cooling/heating)

Speed

Type

Qty x motor output

External static pressure (H-L)

Drive

Type

Rows x stages x fin pitch

Face area high low high high low steps

AIR FILTER

TEMPERATURE CONTROL

PIPING CONNECTIONS liquid gas drain drain

INSULATION MATERIAL Heat insulation

Sound absorbing insulation

For outdoor units Pair application

Twin application

W

Pa mm mm mm kg dB(A) dB(A) dB(A) m 3 m 3

/min

/min mm m 2 mm mm mm mm

FDYMP71L7V1

37/37

33/33

63

19/19

14/14

1 x 130

φ 15.9

I.D.

φ 25

O.D.

φ 32

FDYMP100L7V1

279

987

750

38.1

Painted galvanised steel plate

39/39

34/34

65

0.226

27/27

20/20

3 steps

Sirocco fan

1 x 155

100 - 50

Direct drive

Fin rhombus type, J7 Hi-XA tube

3 x 14 x 1.75

Resin net

Computerised control

φ 9.52

φ 19.1

I.D.

φ 25

O.D.

φ 32

Both liquid and gas pipes

Felt

See chapter RP-L7/B7/RYP-L/RYEP-L7

See chapter RP-L7/B7/RYP-L7/RYEP-L7

FDYMP125L7V1

1,387

48.6

41/41

35/35

66

35/35

24/24

1 x 225

0.344

I.D.

O.D.

φ

φ

25

32

4

Split - Sky Air

Indoor Units

1

2

3

4

5

6

7

2

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

Specifications

ELECTRICAL SPECIFICATIONS

For indoor units only:

CURRENT Nominal running current

Max. running current cooling/heating A cooling/heating A

For combination indoor units + outdoor units:

CURRENT Nominal running current

Max. running current

Starting current cooling cooling cooling

A

A

A

For combination indoor units + outdoor units:

CURRENT Nominal running current

Max. running current

Starting current cooling/heating A cooling/heating A cooling/heating A

For combination indoor units + outdoor units:

CURRENT Nominal running current

Max. running current

Starting current cooling/heating A cooling/heating A cooling/heating A

For indoor units only:

POWER SUPPLY

NOMINAL DISTRIBUTION

SYSTEM VOLTAGE

Phase

Frequency

Voltage

Hz

V

FDYMP71L7V1

FDYMP71L7V1

RP71L7V1/W1-RP71B7T1

FDYMP71L7V1

RYP71L7V1/W1

FDYMP71L7V1

RYEP71L7V1/W1

FDYMP71L7V1

V1

1 ∼

50

230

FDYMP100L7V1

See chapter RP-L7/B7/RYP-L7/RYEP-L7

See chapter RP-L7/B7/RYP-L7/RYEP-L7

FDYMP100L7V1

RP100L7V1/W1-RP100B7T1

See chapter RP-L7/B7

See chapter RP-L7/B7

See chapter RP-L7/B7

FDYMP100L7V1

RYP100L7V1/W1

See chapter RYP-L7

See chapter RYP-L7

See chapter RYP-L7

FDYMP100L7V1

RYEP100L7V1/W1

See chapter RYEP-L7

See chapter RYEP-L7

See chapter RYEP-L7

FDYMP100L7V1

V1

1 ∼

50

230

FDYMP125L7V1

FDYMP125L7V1

RP125L7W1-RP125B7T1

FDYMP125L7V1

RYP125L7W1

FDYMP125L7V1

RYEP125L7W1

FDYMP125L7V1

V1

1 ∼

50

230

3TW25041-1

3TW25051-1

3TW25061-1

1

2

NOTES

Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB * outdoor temperature 35°CDB * refrigerant piping length: 7.5m * level difference: 0m.

Nominal heating capacities are based on: indoor temperature: 20°CDB * outdoor temperature: 7°CDB/6°CWB * refrigerant piping length: 7.5m * level difference 0m.

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

The sound pressure level is measured via a microphone at 1.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter.

The sound power level is an absolute value indicating the ’’power’’ which a sound source generates.

Energy label: scale from A (most efficient) to G (less efficient).

Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions).

Split - Sky Air

Indoor Units 5

3

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

Dimensional drawings

1

3

FDYMP71-100L7

1 Liquid pipe connection J9.52 Flare connection

2 Gas pipe connectionJ A Flare connection

3 Remote control wiring connection

4 Power supply connection

5 Drain pipe connection VP25 (O.D. J 32, I.D. J 25)

6 Air filter

7 Air suction side

8 Air discharge side

9 Name plate view B

960 (Suspension position) view A

Suspension bolt

6

Notes:

1. Refer to ’outlook drawing for installing optional accessories’ when installing optional accessories.

2. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the ’filter installation method’ drawing)

300 mm or more

(Service space)

Model

FDYMP71L7V1

FDYMP100L7V1

A

15.90

19.10

FDYMP125L7

1 Liquid pipe connection J9.52 Flare connection

2 Gas pipe connection J19.10 Flare connection

3 Remote control wiring connection

4 Power supply connection

5 Drain pipe connection VP25 (O.D. J32, I.D. J25)

6 Air filter

7 Air suction side

8 Air discharge side

9 Name plate

1360 (Suspension position) view A

3TW25044-1

Suspension bolt view B

Split - Sky Air

Indoor Units

(Service space)

Notes:

1. Refer to ’outlook drawing for installing optional accessories’ when installing optional accessories.

2. For maintenance of the air filter, it is necessary to provide a service access panel according to the installation method. (Refer to the ’filter installation method’ drawing)

2TW25064-1

4

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

Piping diagrams

FDYMP71-125L7

Heat exchanger

Filter

Liquid pipe connection port

Gas pipe connection port

Cooling

Heating

Refrigerant flow

Refrigerant pipe connection port diameters

FDYMP71L7V1

Model

FDYMP100L7V1

FDYMP125L7V1

Gas

J 15.9

J 19.1

Liquid

J 9.52

J 9.52

1

4

O

Check valve

L

Flare connection

M

Screw connection

N

Flange connection Z Pinched pipe

P

Spinned pipe

3TW25045-1

Split - Sky Air

Indoor Units 7

5

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

Wiring diagrams

1

5

FDYMP71

125L7

Outdoor Indoor

Notes

1. When using the central remote control, see manual for connection to the unit.

2. The infrared remote control model varies according to the combination system.

See technical data and catalogs before connecting.

Wired remote control

Terminals for operation indicator

Details of wired remote control

(optional accessory) g Field wiring D Terminal a : Connector c b

: Wire clamp

: Protective earth (screw)

Colours

BLK: Black/ PPL: purple/ BLU: Blue/

WHT: White/ RED: Red/ GRN: green/

GRY: grey/ YLW:Yellow

A1P

T1R

C1R

F1T

HAP

M1F

R1T

R2T

Printed circuit board

Power supply transformer (transformer 220-240V/

218V)

Capacitor (fan)

Thermal fuse (152°C) (M1F embedded)

Light emitting diode (service monitor green)

Motor (fan)

Thermistor (air)

Thermistor (coil)

RyF1 ∼ 3 Magnetic relay (fan)

SS1

X1M

X2M

RC

Selector switch (emergency)

Terminal strip

Terminal strip

Signal receiver circuit

TC Signal transmission circuit

Group control jumper

J1 Jumper for ’’Master/slave’’ determination BS7

BS11

BS12

BS14

Wired remote control

BS1

BS2

On/Off button

Timer mode start/stop button

BS3,BS8 Programming time button

BS4,BS9 Temperature setting button

BS6 Operation mode selector button

Timer on/off button

Fan speed control button

Inspection/test operation button

Filter sign reset button

Switch box

Adapter for wiring

LED1

LCD

Light emitting diode (service monitor red)

Liquid crystal display (LCD)

SS1 Selector switch (main/sub)

Adapter for wiring

RyC,RyF Magnetic relay

Connector for optional parts

X33A

X35A

X40A

Connector (adapter for wiring)

Connector (group control adapter)

Connector (remote ON/OFF forced OFF)

Cautions for servicing

With the power on, troubles can be monitored on the remote controller or the LED on the PC board of the indoor unit.

Troubleshooting with the display on the liquid crystal of the remote controller.

When the operation stops due to trouble, the operation lamp flashes, ’’b’’ and the error codes are indicated on the liquid crystal display. In this case, diagnose the fault contents by refering to the table on the right. In case of group control, the unit number is displayed so that the indoor unit with the trouble can be recognized (see note 2).

Press the INSPECTION/TEST OPERATION button ’’b’’ is displayed and ’’O’’ flashes.

Press the PROGRAMMING TIME button and find the unit number which stopped due to trouble.

Number of beeps:

3 short beeps ... Perform all the following operations

1 short beep ... Perform j

1 long beep ... No trouble

3

Press the operation mode selector button and upper figure of the error code flashes.

Continue pressing the PROGRAMMING TIME button until it makes 2 short beeps and find the upper code.

Press the OPERATION SELECTOR button and lower figure of the error code flashes.

Continue pressing the PROGRAMMING TIME button until it makes a long beep and find the lower code. A long beep indicates the error code.

Error codes

Malfunction

A1 Indoor unit’s PC board

A6 Indoor fan motor overloaded, overcurrent or locked

AJ Type set error (indoor unit)

Remarks

Capacity data is wrongly preset or there is nothing programmed in the data hold IC.

C4 Sensor for heat exchanger temperature (indoor)

C9 Sensor for suction air temperature (indoor)

CJ Sensor for remote controller The remote controller thermistor does not work, but the system thermo run is possible.

E0 Action of safety device (outdoor unit)

E1 Outdoor unit’s PC board

E3 Abnormal high pressure (outdoor unit)

E4 Abnormal low pressure (outdoor unit)

E9 Electronic expansion valve (outdoor unit)

F3 Abnormal discharge pipe temperature (outdoor unit)

H3 High pressure switch defect (outdoor unit)

H4 Low pressure switch defect (outdoor unit)

H9 Outdoor air thermistor

J3 Discharge pipe thermistor (outdoor unit)

J5 Suction pipe thermistor (outdoor unit)

J6 Heat exchanger thermistor (outdoor unit)

PJ Type set error (outdoor unit)

(See note 3)

(See note 3)

Capacity data is wrongly preset or there is nothing programmed in the data hold IC.

U0 Abnormal suction pipe temperature (outdoor unit)

U1 Reverse phase Reverse 2 of the 3 lead wires

U4 Transmission error (indoor unit - outdoor unit) Transmission indoor - outdoor is improper

U5 Transmission error (indoor unit - remote controller)

UF Miss wiring

Transmission indoor-remote contr. Is improper if group control: check ’master-slave jumper’.

Field wiring is not correct

For the white error codes on a black background, be sure to check and repair, though system may be operated without displaying ’’b.

Notes:

1. Press the INSPECTION / TEST OPERATION button.

’’b starts flashing.

2. Keep down the ON/OFF button for 5 seconds or longer in the inspection mode, and the above trouble history disappears, after the trouble code goes on and off twice, followed by the code ’’00’’

(normal). The display changes from the inspection mode to the normal mode.

3. Equipment operation in response to errors will vary according to the model.

Troubleshooting with the LED on the indoor PC board.

The following checking can be made with the service monitor LED (green) (normal when flashing).

p: LED on s: LED off q: LED flashing

Microcomputer normal monitor

HAP q

Description p s

Normal -> Outdoor unit

Indoor PC board error (see note)

Power supply trouble or PC board error (see note)

NOTE:

Cut off the power and wait for 5 seconds or longer.

Turn on the power again and see if the LED is the same state.

2TW25046-1A

8

Split - Sky Air

Indoor Units

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

6 Sound level

6-1

Sound level data

Sound pressure level

Model

230V, 50Hz

Cooling/Heating

FDYMP71L7V1

FDYMP100L7V1

FDYMP125L7V1

High

37/37

39/39

41/41

Low

33/33

34/34

35/35

Measuring location

Suction

Location of microphone

Unit Discharge

Microphone

6-2

Sound pressure spectrum

FDYMP71L7 FDYMP100L7

Sound power level (H)

(cooling)

1

6

6-1

63

65

66

Octave band center frequency (Hz)

3TW25047-1

Octave band center frequency (Hz)

3TW25057-1

FDYMP125L7

Octave band center frequency (Hz)

3TW25067-1

Split - Sky Air

Indoor Units

Legend

High speed

Low speed

3

4

1

2

NOTES

Data is valid at free field condition

Data is valid at low ESP operation condition. (50 Pa AT 230V) dBA = A-weighted sound pressure level (A-scale according to IEC)

Reference acoustic pressure 0dB = 20µPa

9

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

1

6

6-3

6 Sound level

6-3

Sound power spectrum

FDYMP71L7 FDYMP100L7

3TW25047-2

Octave band center frequency (Hz)

FDYMP125L7

3TW25057-2

Octave band center frequency (Hz)

1

2

3

NOTES

Data is valid at low ESP operation high tap condition. (50Pa at 230V) dB(A) = A-weighted sound power level (A-scale according to IEC)

Measured in duct according to ISO 9614

10

3TW25067-2

Octave band center frequency (Hz)

Split - Sky Air

Indoor Units

7

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

Fan characteristics

FDYMP71L7

Fan curve 71 class motor

FDYMP100L7

Air flow (m 3 /min)

Fan curve 100 class motor

3TW25048-1

1

7

FDYMP125L7

Air flow (m 3 /min)

Fan curve 125 class motor

3TW25058-1

Air flow (m 3 /min)

Split - Sky Air

Indoor Units

3TW25068-1

11

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

8 Accessories

8-1

Optional accessories

1

8

8-1

Item

Remote control

Adapter for wiring (interlock for fresh air intake fan)

Adaptor for external ON/OFF and monitoring

Wired type

71-100-125 Class

BRC1D517

KRP1B59

KRP4A51

Wiring adapte (electrical heater and hour meter EKRP1B2

Installation box

Remote ON/OFF, forced OFF

KRP1B947A

EKR0R0

3TW25049-4B

* Electrical heater and humidifier are field supply. The electrical heater should be installed in the discharge duct.

Wire specifications

Connector (White) connect to indoor PCB (X40A)

AWG24 0.22mm

2 White

White connect to on/off switch

Operating method

ON*

Switch

OFF

ON

Remote control

OFF

ON

Standard setting:

’forced off’

OFF

ON

Alternative setting: ’on/off’

OFF

* Input ’ON’ = closed contact.

12

Forced off

Input ’on’ stops operation + disables control

Input ’off’ enables control

On/off operation

Input off → on: starts operation, remote control is still enabled.

Input on → off: stops operation, remote control is still enabled.

Selection of ’FORCED OFF’ and ’ON/OFF’ operation

Forced off

On/off operation

Setting Mode NO

12 (22)

Split - Sky Air

Indoor Units

First code NO

1

Second code NO

01

02

4TW23941-1

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

9 Control systems

9-1

Wired remote control

BRC1D527

5 x 10 (Round end slit)

5 x 7 (Round end slit) HoleJ5

6.5 x 9 (Round end slit)

Cover closed

1

9

9-1

3TW23651-2

Cover open

Split - Sky Air

Indoor Units 13

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

10 Center of gravity

1

10 FDYMP71-125L7

71 - 100 Class

125 Class

Model A

920

1320

B

420

600

4TW25049-3

11 Safety device settings

FDYMP71-125L7

FDYMP

Model

3TW21009-2C

Safety devices

Fan motor thermal fuse (°C)

71

152±2

100

152±2

125

152±2

14

Split - Sky Air

Indoor Units

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

12 Installation instructions

Preparations before installing Selecting installation site Drain pipe work

Names and functions of parts How to clean the air filter

Service of switch box

Refrigerant piping work Indoor unit installation

Drain pipe work Computerised control (forced OFF and ON/OFF operation)

1TW25049-2

Split - Sky Air

Indoor Units

1

12

Concealed Ceiling Unit

R-407C

FDYMP71-125L7V1/W1

12 Installation instructions

Filter fixing plate

Filter

Detail A

Scale 1/1

Only for 125 class

Only for 71 & 100 class

Only for 125 class

1

2

NOTES

Filter must slide in the filter fixing plates (see detail A)

Filter holding plate must be mounted correct (see detail B)

Filter holding plate

Detail B

Scale 1/1

3TW25044-2

16

Split - Sky Air

Indoor Units

advertisement