Uniden UH506SX-2NB Owner's Manual

Add to my manuals
16 Pages

advertisement

Uniden UH506SX-2NB Owner's Manual | Manualzz

UH506SX-2NB

UHF CB Radio

For more exciting new products please visit our website:

Australia: www.uniden.com.au

New Zealand: www.uniden.co.nz

Controls & Indicators

Included in your Package

• UH506SX-2NB Radio (2)

• Owner’s Manual

• Belt Clip (2)

Optional Accessories

• Speaker MIC

• VOX Headset

• Charging Cradle with AC Adaptor

• NiMH Battery Pack (2)

• Carabiner Clip (2)

14

1

13

15

16

17

18

19

20

21

22

2

3

8

9

23

26

25

24

menu

4

5

6

7

ch scan vol mem

10

11

12

1 Antenna

2 PTT (Push to Talk) Button

3 Call/Monitor Button

4 Channel Up Key

5 Channel Down Key

6 hi/lo lock Key

7 Speaker

8 Accessory Jack

9 Menu/Power Key

10 Volume Up/Scan Key

11 Volume Down/Memory Key

12 Microphone

13 Carabiner Loop

CHARGE

27

14 Channel Indicator

15 TX - Transmit

16 RX - Signal Receive

17 HI - Power Hi/Lo

18 M - Memory Channel

19 VX - Voice Activation Mode

20 BCL - Busy Channel Lockout

21 (CTCSS) - Continuous Tone

Coded Squelch System

22 (DCS) - Digitally Coded Squelch

23 CTCSS/DCS Code

24 Battery Level

25 Keylock

26 Charging Contacts

27 Charge LED

UNIDEN UH506SX-2NB

1

UHF CB Radio

Getting Started

Uniden does not represent this product to be waterproof. Do not expose this product to Rain or Moisture.

NOTE

Battery Installation

Your UH506SX-2NB unit uses the included NiMH battery pack for power.

The unit can be powered with optional 3 AAA ALKALINE batteries*.

*The TX power is always low for alkaline batteries.

NOTE

If you don’t use the UH506SX-2NB for long periods, Uniden recommends removing the batteries.

OLD NEW

To avoid damage to the unit do not mix old and new batteries.

To install the batteries:

1. Make sure your radio is off.

2. Release the battery cover clip, then remove the battery cover.

3. Insert NiMH battery pack according to the orientation on the battery pack.

OR

Insert 3 AAA ALKALINE batteries (not included) according to the polarity

symbols inside the battery compartment.

4. Align the battery cover tabs with the UH506SX-2NB tab holes then

replace the cover clip.

NOTE

Do not charge alkaline or non rechargeable batteries.

UNIDEN UH506SX-2NB

2

UHF CB Radio

Getting Started

Installing the Charge Cradle

1. Plug the AC adaptor into the rear of the charge cradle and into the mains

power.

2. Place the UH506SX-2NB into the charge cradle.

The charge light will come on to indicate the unit is charging.

3. Before operating the UH506SX-2NB, charge the battery pack for 16 hours.

Do not charge alkaline or non rechargeable batteries.

NOTE

User License Information

NOTE

The citizen band radio service is licenced in Australia by

ACMA Radio-communications (Citizen Band Radio Stations)

Class Licence and in New Zealand by MED General User

Licence for Citizen Band Radio and operation is subject to conditions contained in those licences.

UNIDEN UH506SX-2NB

3

UHF CB Radio

Getting Started

Belt Clip

To attach the belt clip:

Slide the belt clip until it snaps into place.

To remove the belt clip:

To remove the belt clip, slightly lift the belt clip locker and slide the belt clip at the same time until released.

Using the Carabiner Clip

Use the carabiner clip to conveniently secure the UH506SX-2NB to a belt or strap.

Low Battery Alert

If the battery level becomes low, the battery indicator icon on the display begins flashing. When the batteries in the unit are low, the unit will go into a battery low mode. The Transmit mode is disabled. Replace the alkaline batteries immediately or if you are using the

NiMH battery pack, place the radio on the charge cradle to recharge. Full charge will take up to 16 Hrs.

Back Light

The UH506SX-2NB has an automatic display back light which remains on for

10 seconds after a key press (all keys except PTT key). The back light will work even if the keypad is locked but will not work during low battery alert mode.

UNIDEN UH506SX-2NB

4

UHF CB Radio

Operation

Power On/Off

1. Press and hold

menu/ to turn the radio on.

A channel number will appear on the display.

2. Press and hold menu/ to turn the radio off.

ch menu scan vol mem

Power Off feature is not available in the Menu mode. Exit Menu mode to use Power Off feature.

NOTE

Volume

The volume level can be adjusted from 0 (min volume) to 7 (maximum volume).

Press (vol) or to increase or decrease the volume level. U and the current volume level will fl ash on the display.

Keypad Lock

To prevent accidental entries, you can lock the keypad. Press and hold

(hi/lo/

lock) for 1.5 secs until it beeps to activate Key Lock. The appears.

To unlock the keypad, press and hold (hi/lo/lock) again for 1.5 Secs. The disappears.

NOTE

While in Keylock on mode, the UH506SX-2NB can still receive and transmit.

UNIDEN UH506SX-2NB

5

UHF CB Radio

Operation

Selecting A Channel

Press (ch) or to select the desired channel. If you press and hold (ch) or the channel numbers will scroll rapidly.

Refer to channel guidelines on page 12. For Australia, Channels

05 and 35 are reserved for Emergency Calls.

NOTE

To Transmit And Receive

The radio uses the UHF-CB Channels.

(Channels 22 and 23 are for telemetry and telecommand applications, channels 61,62 and 63 are for future use.

TX is inhibited on these channels.) ch menu

The maximum RF transmit power of UH506SX-2NB is 0.7W.

1. Before you transmit, listen for activity on the selected channel.

2. When the channel is clear, press (PTT) to transmit at the selected hi/lo

transmit power.

scan vol mem

TX appears on the LCD during transmit.The unit cannot transmit continually for more than 3 minutes. If the user transmits continually for more than 3 minutes, the unit stops transmitting a signal. The TX icon and the Channel segment will blink and sound a tone.

Hold the radio with microphone approximately 5 cm in front of your mouth with the antenna at approximately 45° angle away from your head. Speak in a clear, normal conversational voice.

3. When you have fi nished speaking, release (PTT) for a response then TX disappears on the LCD.

RX appears while receiving a signal.

Transmit Power Select

To change your transmit power level press hi/lo lock. To revert to the previous power level, press the

hi/lo lock again. When the TX Power setting is set to low, HI icon is not displayed on the LCD.When the TX Power setting is set to high, HI icon is displayed on the LCD. The RF transmit power of the

UH506SX-2NB is selectable between 0.7/0.5 W.

UNIDEN UH506SX-2NB

6

UHF CB Radio

Operation

Automatic Squelch Feature

The UH506SX-2NB is equipped with an Automatic Squelch System which shuts off weak transmissions and unwanted noise.

Monitor

This feature enables users to listen in for weak signals on the current channel at the press of a button.

To use monitor,

• For continuous listening. Press and hold

(CALL/MON)

.

A double tone beep will be heard and the receiver circuit will stay open, letting in both the noise & weak signals.

RX flashes.

• To return to normal receive mode press and hold

(CALL/MON)

.

Scanning

The UH506SX-2NB has two types of scanning; Open Scanning (OS) and Group

Scanning (GS), OS Scan searches all the channels and frequencies in its memory continuously. GS Scan is similar to OS scan but has the added ability to monitor the priority channel every 1.5 seconds.

Scanning searchs for active channels programmed in the OS or GS memory.

To initiate scanning,

1. Assuming the unit is on CH01 when switched on.

2. Press and hold vol (scan) and scanning starts.

Open Scan (OS) Mode

Allows continuous scanning of channels stored in the Open Scan (OS) memory.

If an active channel is found, scanning will stop on that channel.

NOTE

The factory has preprogrammed all the UHF-CB channels into the Open Scan channel memory. However, you can change or customise the channels by following the steps on programming

Scan Channels on page 8.

To skip the active channel, press (ch) or . Scanning resumes.

To deactivate SCAN, press (PTT) or press and hold vol (scan).

UNIDEN UH506SX-2NB

7

UHF CB Radio

Operation

Group Scan(GS) Mode

To change between OS and GS scan;

1. Press

2. Press

3. Press & hold

(menu) to save and exit.

To initiate scanning,

1. When

vol scan is pressed during Group Scan Mode, Group Scanning begins.

2. To deactivate GS scanning, press

(PTT) or press and hold vol (scan).

NOTE

1. If SCAN is deactivated while it is tuned to an active

channel, the UH506SX-2NB will stay on that active channel.

If none of the channels re-active, the radio will reinstate the

Scan start channel.

2. If OS/GS Scanning is initiated when there are no channels

programmed in OS/GS memory, an error tone will be heard

and scanning will not start.

Priority Channel Watch During Group Scan

The feature monitors the Priority channel every 1.5 secs during GS.

(menu) four times. Pr setting flashes.

2. Press

3. Press & hold (menu) to save and exit.

Programming Scan Channels

1. Select which Scanning Mode you wish to use on the channel OS or GS Mode.

2. Select the channel you want to store by pressing (ch) or .

3. Press and hold vol (mem) to store.

M icon appears.

4. To remove the channel from Memory, Press and hold vol (mem) to remove. M icon disappears.

Drop-Out Delay

While scanning, the radio stops at a busy channel and receives a signal. When the received signal is over, the unit will wait for 2 seconds for the return of the signal, otherwise, the radio resumes scanning.

UNIDEN UH506SX-2NB

8

UHF CB Radio

Operation

To Operate In Duplex Mode (Repeaters)

The Duplex function enables you to access local repeater stations.

You can only activate Duplex on CH01-CH08 and CH41-CH48.

NOTE

UHF CB Repeaters are used to retransmit or relay your signal. Repeaters will extend the range of your radio and overcome the shielding effect caused by solid obstructions.

Eg. CH01 is being used in your area for repeater use.

(menu) twice. ‘dP’ will flash on the screen.

2. Press

CH01-CH08 and n appears for CH41-CH48 when duplex is selected.

3. Press & hold (menu) to save and exit.

Contact your retailer for a list of repeaters available in your area.

NOTE

Operation with the aid of a Repeater

CTCSS

(Continuous Tone Coded Squelch System)

CTCSS is a feature that allows a group to talk to each other without hearing other users on the same channel.

1. Select desired channel.

(menu) once. CTCSS setting flashes.

3. Press

4. Press & hold (menu) to save and exit.

UNIDEN UH506SX-2NB

9

UHF CB Radio

Operation

Select oF to turn DCS/CTCSS off for the selected channel.

NOTE

DCS

(Digital Coded Squelch)

DCS is a digital extension of CTCSS. It provides 104 extra, digitally coded, squelch codes that follow after the 38 CTCSS codes. CTCSS 1-38, followed by

DCS 1-104.

Follow the steps for changing CTCSS code but select DCS code as desired.

NOTE

Channels 05 and 35 are used for emergency channels. CTCSS and DCS will not operate on these two channels.

VOX

VOX is the automatic transmitting function by inputting voice into the VOX headset mic without pressing the PTT key. While headset microphone is not connected, VOX function is inactive even if VOX level setting is from 1 to 5.

VX appears when VOX level setting is from 1 to 5.

1. Press (menu) seven times. VX setting flashes.

(ch) or or (vol) or to select the desired setting. The 6

VOX levels are from 1 (high sensitivity) to 5 (low sensitivity) and Off.

3. Press & hold

(menu) to save and exit.

Busy Channel Lockout

This feature prevents accidental transmission on a busy channel. For example, BCL is used when CTCSS or DCS is selected to prevent transmission when the radio detects a transmission from another unit using the same CTCSS or DCS code.

(menu) five times. BCL setting flashes.

2. Press

change the setting on or off.

3. Press & hold (menu) to save and exit.

UNIDEN UH506SX-2NB

10

UHF CB Radio

Operation

Call Tone

Your UH506SX-2NB radio is equipped with 5 selectable call tones that will be transmitted when

CALL/MON is pressed.

(menu) six times. CL setting flashes.

2. Press

(ch) or or (vol) or to change the selection. The 5 call tones are CL 1 to CL 5.

A sample of the call tone is sounded when selected.

3. Press & hold (menu) to save and exit.

NOTE

Current regulations require calling tones to be restricted to one transmission per minute. If a second transmission is attempted within one minute then an error tone will sound.

Key Beep

Assures the user that the keypad has been properly pressed by emitting a beep tone. This tone can be switched on or off.

1. Press (menu) nine times. bP setting flashes.

2. Press

3. Press & hold (menu) to save and exit.

Roger Beep

Roger Beep is a BEEP that is sent to notify the end of transmission (both PTT and VOX transmission.) Roger Beep can be heard through the speaker when

Key Beep is on. Roger Beep is transmitted even if Key Beep is turned off.

However, Roger Beep will not be heard from the speaker.

(menu) eight times. rb setting flashes.

2. Press

3. Press & hold (menu) to save and exit.

UNIDEN UH506SX-2NB

11

UHF CB Radio

UHF Channels Guidelines

NOTE

Always listen on a channel (or observe the receive signal level meter) to ensure it is not already being used before transmitting.

Channels 5 and 35 are used for emergency channels.

CTCSS/DCS will not operate on these channels.

Please follow these guidelines for channel use in Australia:

• Channels 05 and 35 are Emergency Channels.

• Channel 11 is a Calling Channel.

• Channels 22 and 23 are for telemetry and telecommand

applications, channels 61, 62 and 63 are for future use and TX

is inhibited on these channels.

General communication is accepted on all other channels with these guidelines:

• Channel 40 - road channel (Australia).

• Channels 01-08 (and 31-38), and Channels 41-48

(and 71-78) are repeater channels.

NOTE

Important information - 80 Channel UHF-CB channel expansion

To provide all users additional channel capacity within the UHF-CB Band.

The ACMA will change the majority of the current wideband 40 channel use to narrowband channel use. This allows for additional channels to be added, up to 80 Channels.

This simply means that the new narrowband radio you have purchased will have more channels than older radios. Please refer to the guidelines above and the channel chart for further channel information.

A list of currently authorised channels can also be obtained from the

ACMA website in Australia and the MED website in New Zealand.

Interference / Poor Audio

When a new narrowband radio receives a signal from an older wideband radio the speech may sound loud.

Narrowband radios operating on CH41 - CH80 may encounter interference from a nearby wideband radios transmitting on high power on an adjacent channel (frequency).

When an older wideband radio receives a signal from a new narrowband radio the speech may sound quiet - the wideband radio user simply adjusts their radio volume for best performance.

The above situations are not a fault of the radio but a symptom of mixed wideband and narrowband radios in current use. It is expected that as older wideband radios are phased out this issue will be eliminated.

UNIDEN UH506SX-2NB

12

UHF CB Radio

Warranty

UNIDEN UH506SX-2NB UHF-CB Radio

IMPORTANT: Satisfactory evidence of the original purchase is required for warranty service

Please refer to our Uniden website for any details or warranty durations offered in addition to those contained below.

Warrantor: The warrantor is either Uniden Australia Pty Limited ABN 58 001

865 498 (“Uniden Aust”) or Uniden New Zealand Limited (“Uniden NZ”) as the case may be.

Terms of Warranty: Uniden Aust/NZ warrants to the original retail purchaser only that the UH506SX-2NB Radio (“the Product”), will be free from defects in materials and craftsmanship for the duration of the warranty period, subject to the limitations and exclusions set out below.

Warranty period: This warranty to the original retail purchaser is only valid in the original country of purchase for a Product first purchased either in Australia or New Zealand and will expire one (1) year from the date of the original retail sale.

If a warranty claim is made, this warranty will not apply if the Product is found by Uniden to be:

(A) Damaged or not maintained in a reasonable manner or as recommended

in the relevant Uniden Owner’s Manual;

(B) Modified, altered or used as part of any conversion kits, subassemblies or

any configurations not sold by Uniden Aust or Uniden NZ;

(C) Improperly installed contrary to instructions contained in the relevant

Owner’s Manual

(D) Repaired by someone other than an authorized Uniden Repair Agent

in relation to a defect or malfunction covered by this warranty; or

(E) Used in conjunction with any equipment, parts or a system not

manufactured by Uniden.

Parts Covered: This warranty covers the Product and included accessories.

User-generated Data: This warranty does not cover any claimed loss of or damage to user-generated data (including but without limitation phone numbers, addresses and images) that may be stored on your Product.

UNIDEN UH506SX-2NB

13

UHF CB Radio

Warranty

Statement of Remedy: If the Product is found not to conform to this warranty as stated above, the Warrantor, at its discretion, will either repair the defect or replace the Product without any charge for parts or service. This warranty does not include any reimbursement or payment of any consequential damages claimed to arise from a Product’s failure to comply with the warranty.

Our goods come with guarantees that cannot be excluded under the Australian

Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.

You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

This warranty is in addition to and sits alongside your rights under either the

COMPETITION AND CONSUMER ACT 2010 (Australia) or the CONSUMER

GUARANTEES ACT (New Zealand) as the case may be, none of which can be excluded.

Procedure for obtaining warranty service: Depending on the country in which the Product was first purchased, if you believe that your Product does not conform with this warranty, you should deliver the Product, together with satisfactory evidence of your original purchase (such as a legible copy of the sales docket) to Uniden at the addresses shown below. You should contact

Uniden regarding any compensation that may be payable for your expenses incurred in making a warranty claim. Prior to delivery, we recommend that you make a backup copy of any phone numbers, images or other data stored on your Product, in case it is lost or damaged during warranty service.

UNIDEN AUSTRALIA PTY LTD

Service Division

345 Princes Highway,

Rockdale, NSW 2216

Phone: 1300 366 895

Email: [email protected]

UNIDEN NEW ZEALAND LTD

Service Division

150 Harris Road, East Tamaki

Auckland 2013

Phone: (09) 273 8377

Email: [email protected]

UNIDEN UH506SX-2NB

14

UHF CB Radio

THANK YOU FOR BUYING A UNIDEN PRODUCT.

© 2012 Uniden Australia Pty Limited. Uniden New Zealand Ltd. Printed in PRC.

U01UT952ZZZ(0)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement