User's Guide Extech EX840 True RMS 1000 Amp

Add to my manuals
13 Pages

advertisement

User's Guide Extech EX840 True RMS 1000 Amp | Manualzz

User's Guide

Extech EX840 True RMS 1000 Amp

Clamp Meter with IR Thermometer

Patented

Introduction

Congratulations on your purchase of the Extech EX840 CAT IV True RMS 1000A Clamp

Meter. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance,

Frequency, Duty Cycle, Diode Test, Continuity, Type k thermocouple thermometer plus

Non-Contact IR Temperature. Proper use and care of this meter will provide many years of reliable service.

Safety

International Safety Symbols

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present

Double insulation

SAFETY NOTES

• Do not exceed the maximum allowable input range of any function.

• Do not apply voltage to meter when resistance function is selected.

• Set the function switch OFF when the meter is not in use.

• Remove the battery if meter is to be stored for longer than 60 days.

WARNINGS

• Set function switch to the appropriate position before measuring.

• When measuring volts do not switch to current/resistance modes.

• Do not measure current on a circuit whose voltage exceeds 600V.

• When changing ranges always disconnect the test leads from the circuit under test.

A AC, ADC

V DC, V AC

1000A DC/AC

1000V DC/AC

Resistance, Capacitance, Frequency, Diode Test 250V DC/AC

Type K Temperature 60V DC, 24V AC

2 EX840-EU-EN V5.0 3/09

CAUTIONS

• Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter.

• Always remove the test leads before replacing the battery or fuses.

• Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use.

• Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard.

• Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests.

• Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live".

• If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

• This device is not a toy and must not reach children’s hands. It contains hazardous objects as well as small parts that the children could swallow. In case a child swallows any of them, please contact a physician immediately

• Do not leave batteries and packing material lying around unattended; they can be dangerous for children if they use them as toys

• In case the device is going to be unused for an extended period of time, remove the batteries to prevent them from training

• Expired or damaged batteries can cause cauterization on contact with the skin.

Always, therefore, use suitable hand gloves in such cases

• See that the batteries are not short-circuited. Do not throw batteries into the fire.

Do not directly view or direct the laser pointer at an eye. Low power visible lasers do not normally present a hazard, but may present some potential for hazard if viewed directly for extended periods of time

3 EX840-EU-EN V5.0 3/09

Description

Meter Description

2. Clamp opening trigger

3. Data Hold Button

4. Mode

5. Peak

6. Range

7. DCA Zero (EX830 only)

8. MIN/MAX

9. Backlit LCD Display

10. Test lead input jacks

11. IR thermometer and laser pointer (rear)

13. Laser pointer button

Display icons Description

Minus sign Negative reading display

0 to 3999 Measurement display digits

ZERO Zero

AUTO

DC/AC

Auto Range mode

Direct Current / Alternating

Current

6

9

3

5

10

1

2 mV or V Milli-volts or Volts (Voltage) o

F and o

C Fahrenheit and Celsius units (Temperature) n, m,

μ, M, k Unit of measure prefixes: nano, milli, micro, mega, and kilo

) ) test

Diode test

Laser pointer

4 EX840-EU-EN V5.0 3/09

11

12

13

14

8

Operation

NOTES: Read and understand all Warning and Caution statements in this operation manual prior to using this meter. Set the function select switch to the OFF position when the meter is not in use.

AC Current Measurements

WARNING: Ensure that the test leads are disconnected from the meter before making current clamp measurements.

1. Set the Function switch to the A

AC or A

DC

range

2. Press the trigger to open the jaw.

Fully enclose only one conductor.

For optimum results, center the conductor in the jaw.

3. The clamp meter LCD will display the reading.

DCA ZERO

The DC Zero feature removes offset values and improves accuracy for DC current measurements. To perform a zero, select ADC and with no conductor in the jaw:

Correct Incorrect

zero the display. “ZERO” will appear in the display. The offset value is now stored and removed from all measurements.

2. To view the stored value, press the DC ZERO button. “ZERO” will flash and the stored value will be displayed.

3. To exit this mode, press and Hold the ZERO button until “ZERO” is no longer in the display.

AC/DC Voltage Measurements

1. Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal.

2. Set the function switch to the V

AC

or V

DC

position.

4. Connect the test leads in parallel to the circuit under test.

5. Read the voltage measurement on the LCD display.

5 EX840-EU-EN V5.0 3/09

Resistance Measurements

Note: Remove power before making resistance measurements

1. Insert the black test lead into the negative COM terminal and the red test lead into the

Ω positive terminal.

2. Set the function switch to the

Ω position.

3. Touch the test probe tips across the circuit or component under test.

4. Read the resistance on the LCD display.

Capacitance Measurements

WARNING: To avoid electric shock, discharge the capacitor under test before measuring. If “dISC” appears in the display, remove and discharge the capacitor.

1. Set the function switch to the

capacitance position.

2. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the CAP positive jack.

3. Press MODE to zero any stray capacitance.

4. Touch the test probe tips across the part under test.

5. Read the capacitance value in the display.

6. The display will indicate the proper decimal point and value.

Note: For very large values of capacitance measurement time can be several minutes before the final reading stabilizes.

Frequency Measurements

1. Set the function switch to the V Hz Position.

2. Press and hold the MODE button to select the Frequency (Hz) function. “k Hz” will appear in the display.

3. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the Hz positive jack.

4. Touch the test probe tips across the part under test.

5. Read the Frequency value on the display.

6. The display will indicate the proper decimal point and value.

7. Press and hold the MODE button again to return to the voltage mode

Ù

CAP

Hz

6 EX840-EU-EN V5.0 3/09

Type K Temperature Measurements

1. Set the function switch to the K Temp position.

2. Insert the Temperature Probe into the negative COM and the positive TEMP jacks, observing polarity.

3. Touch the Temperature Probe tip to the device under test.

Continue to touch the part under test with the probe until the reading stabilizes.

4. Read the temperature on the display. The digital reading will indicate the proper decimal point and value.

WARNING: To avoid electric shock, be sure the thermocouple probe has been removed before changing to another measurement function.

Note: An open input or a temperature overrange the meter will display

OL” and beep.

Note: See the “Temperature Units” paragraph to select

°F or °C

Note: The temperature range of the supplied thermocouple probe is -20 to 250°C (-4 to

482°F)

Continuity Measurements

1. Insert the black test lead into the negative COM terminal and the red test lead into the

Ω positive terminal.

2. Set the function switch to the •) ) ) position. the •) ) ) . The display icons will change when the

MODE button is pressed.

4. Touch the test probe tips across the circuit or component under test.

5. If the resistance is < 40

Ω, a tone will sound.

Diode Test

1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive jack

2. Turn the function switch to position. Use the MODE button to select the diode function if necessary (diode symbol will appear on the LCD when in Diode test mode)

3. Touch the test probe tips to the diode or semiconductor junction under test. Note the meter reading

4. Reverse the test lead polarity by reversing the red and black leads. Note this reading

5. The diode or junction can be evaluated as follows:

If one reading displays a value (typically 0.400V to 0.900V) and the other reading displays OL, the diode is good.

If both readings display OL the device is open.

If both readings are very small or ‘0’, the device is shorted.

7 EX840-EU-EN V5.0 3/09

Non-Contact InfraRed Temperature Measurements

1. Set the function switch to the IR Temp position.

2. Aim the infrared sensor (rear of the meter) at the surface to be measured.

3. Press the button in the center of the rotary function switch to turn on the laser pointer and identify the surface spot to be measured.

4. The area of the surface to be measured must be larger than the spot size as determined by the distance to spot size specification.

5. Read the temperature in the display.

Note: See the “Temperature Units” paragraph to select o

F or o

C

WARNING: Do not directly view or direct the laser pointer at

an eye. Low power visible lasers do not normally present a hazard, but may present some potential for hazard if viewed directly for extended periods of time.

IR Spot to Distance Diagram

The 8:1 spot to distance ratio determines the size of the measured surface area with respect to the distance the meter is held away from the surface.

Diameter of spot

7.5cm

1.25cm

2.5cm

10cm

20cm

60cm

Distance to object

IR Measurement Notes

1. The object under test should be larger than the spot (target) size calculated by the field of view diagram.

2. If the surface of the object under test is covered with frost, oil, grime, etc., clean before taking measurements.

3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring.

4. The meter may not make accurate measurements through transparent surfaces such as glass.

5. Steam, dust, smoke, etc. can obscure measurements.

6. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down motion) until the hot spot is located.

8 EX840-EU-EN V5.0 3/09

Data Hold

To freeze the LCD reading, press the HOLD button. While data hold is active, the HOLD icon appears on the LCD. Press the HOLD button again to return to normal operation.

Peak Hold

The Peak Hold function captures the peak AC or DC voltage or current. The meter can capture negative or positive peaks as fast as 1 millisecond in duration.

1. Turn the function switch to the A or V position.

3. Allow time for the display to stabilize.

4. Press and Hold the PEAK button until “CAL” appears in the display. This procedure will zero the range selected.

6. The display will update each time a higher positive peak occurs. indicate the lowest negative peak.

8. To return to normal operation, press and hold the PEAK button until the Pmin or

Pmax indicator switches off.

Note: If the Function switch position is changed after a calibration the Peak Hold calibration must be repeated for the new function selected.

MAX/MIN

"MAX" will appear. The meter will display and hold the maximum reading and will update only when a new “max” occurs.

The meter will display and hold the minimum reading and will update only when a new “min” occurs the present reading, but will continue to update and store the max and min readings.

4. To exit MAX/MIN mode press and hold the MAX/MIN key for 2 seconds.

Temperature Units (˚F / ˚C)

The temperature units selection switch is located in the battery compartment. To change the units, remove the battery door, lift out the battery and set the switch for the desired units.

Units Switch

F C

LCD Backlight Button

The LCD is equipped with backlighting for easier viewing, especially in dimly lit areas. Press the backlight button to turn the backlight on. Press again to turn the backlight off.

Automatic Power OFF

In order to conserve battery life, the meter will automatically turn off after approximately 25 minutes. To turn the meter on again, turn the function switch to the OFF position and then to the desired function position.

9 EX840-EU-EN V5.0 3/09

Maintenance

WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case.

Cleaning and Storage

Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for 60 days or more, remove the battery and store it separately.

Battery Replacement

1. Remove the Phillips head screw that secures the rear battery door

2. Open the battery compartment

3. Replace the 9V battery

4. Secure the battery compartment

You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household garbage is prohibited!

You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold!

Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle

10 EX840-EU-EN V5.0 3/09

Specifications

Function

AC Current

50/60 Hz

DC Current

AC Voltage

50/60Hz

DC Voltage

Resistance

Capacitance

Frequency

Range & Resolution

400.0 AAC

Accuracy (% of reading + digits)

± (2.5% + 8d)

1000 AAC ± (2.8% + 5d)

400.0 ADC

1000 ADC

400.0 mVAC

4.000 VAC

40.00 VAC

400.0 VAC

1000 VAC

400.0 mVDC

± (2.5% + 5d)

± (2.8% + 5d)

± (1.0% + 10d)

± (1.5% + 5d)

± (2.0% + 5d)

± (0.8% + 2d)

4.000 VDC

40.00 VDC

400.0 VDC

1000 VDC

400.0

Ω

4.000k

Ω

40.000k

Ω

400.0k

Ω

4.000M

Ω

40.00M

Ω

4.000nF

± (1.5% + 2d)

± (2.0% + 2d)

± (1.0% + 4d)

± (1.5% + 2d)

± (2.5% + 3d)

± (3.5% + 5d)

± (5.0% + 30d)

± (5.0% + 20d) 40.00nF

400.0nF

4.000µF

40.00µF

± (3.0% + 5d)

400.0µF

4.000mF

± (4.0% + 10d)

± (10% + 10d)

40.00mF unspecified

4.000kHz

± (1.5% + 2d)

Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401Hz to 4000Hz)

11 EX840-EU-EN V5.0 3/09

Function

Temperature

(type-K)

Temp

(IR)

Clamp jaw opening

Display

Continuity check

Diode test

Low Battery indication

Range and Resolution

-4 to 1400 o

-20 to 760 o

-58 to -4

-4 to 518

-50 to -20

F

C

°F

-20 to 270

°F

°C

°C

Accuracy (% of reading + digits)

± (3%rdg + 9 o

F)

± (3%rdg + 5 o

C)

± 9 °F

±2.0% reading or

± 4°F whichever is >

±5°C

±2.0% reading or ±2°C whichever is >

1.7" (43mm) approx.

3-3/4 digits (4000 counts) backlit LCD

Threshold 40

Ω; Test current < 0.5mA

Test current of 0.3mA typical;

Open circuit voltage < 3VDC typical

Battery symbol is displayed

Measurement rate

PEAK

2 readings per second, nominal

Captures peaks >1ms

Thermocouple sensor

IR Spectral response

IR Emissivity

IR distance ratio

Type K thermocouple required

6 to 16µm

0.95 fixed

8:1

10M

Ω (VDC and VAC)

Input Impedance

AC bandwidth

AC response

50 to 400Hz (AAC and VAC)

True rms (AAC and VAC)

Crest Factor

Operating Humidity

3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range)

Operating Temperature 41

°F to 104°F (5°C to 40°C)

Storage Temperature -4

°F to 140°F (-20°C to 60°C)

Max 80% up to 87

°F (31°C) decreasing linearly to 50% at

104

°F(40°C)

Storage Humidity

Operating Altitude

Battery

Auto power OFF

Dimensions & Weight

Safety

Patent notice

<80%

7000ft. (2000meters) maximum.

One (1) 9V Battery (NEDA 1604)

After approx. 25 minutes

10.6x4.3x2” (270x110x50mm); 13.6 oz. (386g)

For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001)

Overvoltage Category IV 600V and Category III 1000V,

Pollution Degree 2.

U.S. Patent 7163336

12 EX840-EU-EN V5.0 3/09

Warranty

EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants this instrument to be free

of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781)

890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A

Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product.

The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.

Calibration and Repair Services

Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy.

Support line (781) 890-7440

Technical support: Extension 200; E-mail: [email protected]

Repair & Returns: Extension 210; E-mail: [email protected]

Product specifications subject to change without notice

For the latest version of this User’s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com

Copyright © 2009 Extech Instruments Corporation )a FLIR company)

All rights reserved including the right of reproduction in whole or in part in any form.

13 EX840-EU-EN V5.0 3/09