Agility Series UPS (750 - 3000 VA) Chloride
Secure Power Always
Agility
Series
UPS (750Solutions
- 3000 VA)
Chloride
Connectivity
Product data sheet
Secure Power Always
MopUPS®® Software connectivity solutions
Software for UPS monitoring and
safe shutdown of computers
running Microsoft Windows,
Unix, or Open Systems.
MopUPS
express
MopUPS
professional
MopUPS P/R
MopUPS (Network Shutdown Agent)
MopUPS Express
Used in stand alone PC or LAN Server applications with local administrators. Provides on-screen UPS status, data, event logging, and controlled
shutdown of a single Microsoft® Windows® computer.
MopUPS Professional
Used in applications where one or more servers on a single UPS require graceful shutdown during extended power failures. Professional
networking capabilities include e-mail event messaging, remote administration, remote monitoring integration with ManageUPS CIO and
shutdown of multiple Windows servers via remote log-in over TCP/IP. Supports selected Windows, Linux, and Unix operating systems.
MopUPS Professional P/R Edition - for Parallel/Redundant UPS Systems
Serves as a central monitoring station for parallel UPS system. UPS status information is retrieved via TCP/IP network connection to ManageUPS
net
adapters.
Perfect for server clusters and blade servers powered by redundant UPSs. P/R monitors redundant server UPS and remote UPS powering
SANs, switches, routers or other IT infrastructure that servers may depend on. Notifies when load levels or module faults threaten UPS
redundancy or availability of remote network resources. Run MopUPS P/R on one or two hosts in a server set and control shutdown of
remaining servers via integrated Network Shutdown Controller. Supports selected Windows, Linux, Unix operating systems.
MopUPS NSA (Network Shutdown Agent)
MopUPS NSA is used when centralized shutdown of multiple computers simplifies configuration and setup. MopUPS NSA listens on the
network for shutdown notification from the Network Shutdown Controller in MopUPS P/R (shared parallel UPSs) or ManageUPS Net (shared
single UPS). Supports selected Windows , Linux, Unix operating systems.
MopUPS Software connectivity solution
OS Support
MopUPS Express
MopUPS Professional
MopUPS P/R Edition
MopUPS NSA (Network
Shutdown Agent)
•Intel based system
•Intel Based Systems
–– MopUPS Professional for
RedHat (6-8)
–– MopUPS Professional for
RedHat (ES 3/4/5)
–– MopUPS Professional for
RedHat Fedora Core 6
–– MopUPS Professional for
SUSE 9/10
–– MopUPS Professional for
Windows 2000, XP, 2003,
Vista, 2008
•Intel Based Systems
–– MopUPS PR for Windows 2000/
XP/2003/Vista
–– MopUPS PR for RedHat 9/ES
–– MopUPS PR for RedHat 9/ES IA64
–– MopUPS PR for SUSE 9/10
–– MopUPS PR for Solaris Intel 10
•Intel Based Systems
–– MopUPS NSA for Windows 2000/
XP/2003/Vista/2008
–– MopUPS NSA for RedHat 9/ES
–– MopUPS NSA for RedHat 9/ES IA64
–– MopUPS NSA for SUSE 9/10
–– MopUPS NSA for Solaris Intel 10
–– MopUPS NSA for VMWare ESX Server
3.0-3.5 & 4
•Vista, Windows 7,
Windows (NT4/2000/XP)
•Non Intel Based Systems
–– MopUPS PR for Solaris SPARC 8-10
•Non Intel Based Systems
–– MopUPS NSA for Solaris SPARC 8-10
•Risc/Sparc Based Systems
–– MopUPS Professional for AIX
(4.3.3/5.x)
–– MopUPS Professional for
HP-UX 11.11
–– MopUPS Professional for
Solaris 5
–– MopUPS Professional for
Solaris 8-10
Bundled UPS*
Desk Power, ONePlus
UPS
Active, Sinergy S II Series, ON Series
Universal Mount, Agility
Requirements
•Serial UPS Monitoring
requires dedicated
computer serial port.
•Serial UPS Monitoring requires
dedicated computer serial port.
•Network SMTP server for email messaging
on non Unix/Linux systems.
•Installation requires user account with
Administrator rights (root login).
•Network Monitoring requires
TCP/IP ethernet connection and
ManageUPSnet Adapter.
•Email notification using SMTP server
configured for open mail relaying
•X-Windows required for Unix and Linux
installations.
•Installation requires user account with
Administrator rights (root login).
•Windows installations require MSI Installer
support
•Installation requires
user account with
Administrator rights
(root login).
•USB on Desk Power
Series and Active Series
UPSs supported in
Windows 2000/XP/2003
with use of USB Driver.
•Network SMTP server for email
messaging on non Unix/Linux
systems.
•Email notification using SMTP
server configured for open mail
relaying
•Installation requires user account
with Administrator rights (root
login).
•WinSock v2 or higher. Only effects
Windows95 and Windows98.
•USB on Power Series and Active
Series UPSs supported in Windows
2000/XP/2003 with use of USB
Driver.
•X-Windows libraries required for
Unix and Linux installations.
MopUPS Software connectivity solution
•UPS Monitoring requires TCP/IP ethernet
connection and ManageUPSnet Adapter on
each UPS module that are routable from
the IP of the MopUPS host system.
•X-Windows required for Unix and Linux
installations.
•Windows installations require MSI Installer
support
Features
MopUPS Express
MopUPS Professional
MopUPS P/R Edition
MopUPS NSA (Network
Shutdown Agent)
Safe system shutdown.
•Remote Management Site power
and UPS status information can be
access securely from any computer
on your IP based network when
MopUPS Professional is being
used as a stand alone software that
is connected directly to the UPS.
View event history and voltage
logs for trend analysis. View UPS
system status in real time for
situational decision support. Access
is based on User Authentication
with 128bit, MD5 encryption.
•Power Management
Centralized graphical view utility view
MopUPS services and network shutdown
agents on remote systems.
•Authenticated Login
MopUPS NSA is a light version of the
MopUPS service that does not monitor a
UPS but listens for shutdown command from
a password authenticated remote MopUPS
service.
•Remote Messaging
Keeps you informed anywhere
-- fault and recovery messages are
sent via SNMP Trap or email. Body
of email will include URL for quick
link back to UPS Web page. Many
pager systems will forward email to
your wireless pager - so you can be
informed anywhere.
•Safe Network Shutdown
Coordinated shutdown for
networked computers on a shared
power source
•MopUPS provides several networkshutdown methods for flexibility,
simplicity, and reliability to
automate unattended emergency
shutdowns.
•Safe System Shutdown
Perserve data integrity and
minimize recovery delays with
automated system shutdown.
MopUPS monitors the UPS for
power fail, low battery, or other
events that jeopardize computer
power -- and initiates controlled
system shutdown.
•Scripting Engine (Unix/Linux)
Write custom installation and
configuration scripts for your
multiple system installations or for
continued program management.
•Easy navigation between Module, System,
and Host level views provided convenient
real time statue viewing for situational
decision support.
•Intuitive view utility charts power data
graphically and sorts event history log
entries by date/time, event origin, or event
type for simplified trend analysis.
•Remote Messagesing
Keeps you informed anywhere -- fault and
recovery messages are sent via SNMP Trap
or email. Body of email will include URL for
quick link back to UPS Web page. Many
pager systems will forward email to your
wireless pager - so you can be informed
anywhere.
•Safe Network Shutdown
Coordinated shutdown for networked
computers on a shared power source
•MopUPS provides several networkshutdown methodologies that give
you flexibility, simplicity, and reliability
to automate unattended emergency
shutdowns.
•Scalability
Network license mechanism lets you add
licensed services as needed - add modules
as needed, add systems as needed. Adjust
system redundancy settings from N+0 to
N+N. Manage multiple dependencies when
servers depend on remote storage or other
network infrastructure elements powered
by separate UPS.
•System Security
Username/Password, port selection, and IP
Filtering options let you define the security
level you need to secure remote access
from the GUI or network shutdown service.
Username and Password authentication
uses 128bit MD5 encryption when these
keys are passed over the network.
NOTE: to download any of the MopUPS products go to http://connectivity.chloridepower.com and click on products.
MopUPS Software connectivity solution
•Localized Script Execution
MopUPS NSA can be configured to call a
script on its host computer before executing
OS shutdown.
Secure Power Always
®
®
MopUPS
Software
connectivity
solutions
ManageUPS
net Adapter
connectivity
solutions
Micro-computers
with embedded software
for UPS and environment
monitoring
ManageUPS net adapter
(SNMP/WEB/MODBUS)
ManageUPS net adapter
with Environmental Sensor
ManageUPS net
with MODBUS
ManageUPS ValuePoint
adapter
net adapter
ManageUPS P Series - Full Featured Management Adapters for UPS and Environment
ManageUPS net P Series adapters provide: embedded WEB server for configuration and information access, SNMP agents for UPS and
Environment Sensor, data/event Logging, e-mail Event Messaging, Network Shutdown Controller, DHCP client for automatic configuration,
FTP server for network update of firmware and configuration files via ManageUPS DCU. Environment Sensor and/or MODBUS Server (slave)
options can be ordered in the packages below, or added later in the field.
P Series Options
ManagUPS net Adapter +E - Environmental Sensor Option
ManageUPS +E models includes 1 Environment Sensor module and 5 meter Blue Bus cable. Additional sensors (sold separately) can be
added to cover multiple zones.
ManagUPS Net Adapter +B - MODBUS Option
ManageUPS +B simplifies integration of Chloride UPS systems with building monitoring and automation systems via MODBUS RTU,
MODBUS/TCP or JBUS protocols.
ManageUPS VP Series - SNMP/WEB Management Adpaters for single-phase UPS
The VP Series is designed for single-phase UPS applications that do not require Environment Monitoring or MODBUS RTU options. All other
aspects, the VP Series provides the same functions as the full-featured P Series: SNMP/WEB, data/event Logging, e-mail Event Messaging,
Network Shutdown Controller, DHCP configuration and network update of firmware and configuration files via ManageUPS DCU. VP Series
hardware platform is limited to Ethernet connectivity only.
ManageUPS Net Adapter and ManageUPS Net VP Adapter connectivity solution
ManageUPS net Adapter & ManageUPS net VP
Requirements
•Network connection is 10/100 Base-T Ethernet - Ethernet Class 1 (DIX) packet format 802.3u Compliant - Compatible w/FastEthernet full/half duplex
•Web interface requires a W3C standards compliant web browser
•Automatic network configuration requires a DHCP Server
•E-mail requires SMTP Server
•SNMP trap requires SNMP trap receiver
•Log functions work best with access to NTP (network time) server.
Features
•DHCP Network Configuration
Supports automatic configuration of IP settings using the DHCP protocol. DHCP server must be located on the same local network as the ManageUPS .
•Multiple Networked Access Methods
Site power and UPS status information can be accessed securely from any computer on your network. View UPS system status in real time for situational
decision support. Access via Telnet, SNMP, or Web Browser.
•Network Shutdown
ManageUPS Network Shutdown Controller calls shutdown of computers running MopUPS NSA (Network Shutdown Agent) or RCCMD. Multiple schedules
allow for graceful load shedding during extended outages to preserve battery autonomy for the most critical loads.
ManageUPS UPS Status Server allows computers running MopUPS Professional or MopUPS Special Edition for Parallel or Redundant Systems to share UPS
status information. This allows server group administrators to tailor their own automated power-fail- response scenarios.
Both methods can be used simultaneously, and in various combinations to allow complete flexibility in tailoring sophisticated power-fail-response plans for a
wide range of operating systems.
•Security
Telnet, Web, and SNMP servers can be individually disabled. SNMP server uses communities to restrict access. Web, Telnet and FTP servers have username
and password access control. Web server uses basic HTTP authentication. Passwords used for Network Shutdown authentication are encrypted via MD5.
•Serviceability
Allows firmware or configuration files to be updated over the network for simple maintenance. Using ManageUPS DCU for simplified updating and version
management.
•Event and Data Logging
On-board “flash drive” holds log files of UPS events, system events, & UPS data. WEB interface allows convenient log viewing utility and quick-link download
button. Log files can also be retrieved via FTP.
•Event Messaging
UPS events can trigger SNMP trap and/or e-mail event messages. E-mail message options include long, short and short-no-subject format options for easy
forwarding via SMS or wireless handheld devices.
•SNMP Agents
Embedded SNMP Agent conforms to SNMP RFC’s -- RFC1213 (MIB II) and RFC1628 (Standard UPS MIB).
•Simplified Network Configuration via DHCP and ManageUPS DCU.
Deploy-first, configure remotely -- or configure first, then deploy.
You choose what works best for your situation.
•No need for cumbersome serial port setup and text menu configuration via terminal emulators in a staging area. Use ManageUPS DCU (Discover and
Configuration Utility) to automatically discover ManageUPS adapters on your LAN -- or search for them on your WAN -- and quickly navigate to key settings
WEB pages. Change network parameters to fixed IP settings if your network policy prefers manual IP administration.
•ManageUPS accepts network parameters automatically via DHCP (RFC2131 & RFC2136 for DDNS).
In LANs without DHCP servers, ManageUPS negotiates a “link-local” address.
•OnBoard Help
Help files for parameter definition and configuration assistance are on board -- “?” links are context-sensitive and open html-help files in a separate window.
ManageUPS Net Adapter and ManageUPS Net VP Adapter connectivity solution
Secure Power Always
ManageUPS® CIO Software connectivity solutions
Central monitoring system for
distributed UPS and other critical
infrastructure components
ManageUPS CIO Software
• Visualize incident locations
Multi-level Pin-Map feature helps you visualize the location of UPS with alarm conditions. Alarm View lists all devices by type of active
alarm.
• Manage alarm storms
Some incidents, such as power fail or network fail, can be localized or broad-based - affecting multiple UPS connections simultaneously.
ManageUPS CIO can reduce these incidents to a single alarm notification summarizing the number and identities of affected UPS.
• Simple to install and set up
Install ManageUPS CIO on a central server to continuously monitor UPS attached to the network. Automated discovery mechanisms
make it easy to populate the UPS asset list in minutes.
• Flexible to use
All List Views are easily sorted on any column for easy review and analysis. Groups and SmartGroup features simplify analysis and report
generation tasks. The folders feature lets you organize Groups and SmartGroups to reduce clutter. Enable secure remote access to the
monitored inventory from other computers on your network using the browser-like GUI application.
• One click device navigation
Right click on any device icon or list entry to open the device detail page or access the device WEB server.
• One tool for all ups
ManageUPS CIO is the one management tool for all your UPS assets. Monitor Chloride UPS products or 3rd party UPS.
• BACnet over IP support
This additionally licensed feature enables information from ManageUPS-CIO server to be retrieved by the BMS (Building Monitoring
System) via BACnet IP Protocol. The BMS can then send selective information to required personnel or other management systems.
ManageUPS CIO Software connectivity solution
dfsd
Requirements
ManageUPS CIO Software
•UPS Agent Compatibility
–– Chloride ManageUPS net adapter (UPS)
–– Chloride ManageUPS +E net adapter (UPS & Environment Sensors)
–– Chloride MopUPS software (Proxy Agent for Low Power UPS)
–– 3rd party UPS SNMP adapters (RFC1628 standard UPS MIB or Powernet UPS MIB)
•Hardware Requirements
–– Server class 32-bit x86 (Intel compatible) computer
–– 1GHz CPU
–– 1GB RAM
–– Ethernet network adapter
•Email Notification
–– Email notification using SMTP server configured for open mail relaying
Features
•Multi-level Pin-Map
Helps visualize problem locations. Map level backgrounds are any image files (JPG, GIF, PNG). Use any combination of Geographic Maps (starter set included),
Floor plans, Visio drawings, even digital photos of specific installations.
•Alarm View
Automatically organizes devices by current alarm type. Acknowledge alarms to reset their Pin Map representation to normal.
•Smart Groups
Rules-based container for inventory analysis and condition monitoring with e-mail change notification.
•Groups
A container for organizing assets manually - for standard reports or quick view of specific asset sub-sets.
•Folders
Containers for organizing Groups, Smart-Groups and other Folders to help minimize clutter.
•Add Devices
CIO makes it easy to build a UPS asset list - CIO automatically discovers UPS on the local LAN segment -- simple search utility finds UPS on remote sub-nets.
•Print Reports
Send formatted reports to a printer or PDF writer for archive or sharing with others.
•Export
Export lists from any list view to CSV files for further analysis via spreadsheet or archive database.
This compay has a policy of continuous product development and improvement and we therefore reserve the right to vary any infomration or specification without prior notice.
ManageUPS and MopUPS are a egistered trademark of ONEAC. All other tademarks, product, and corporate names are the property of their respective owners.
© 2009 Chloride
T 800 327 8801, 847 816 6000
F 847 680 5124
www.chloridepower.com/usa
917-221 @ Rev. -
Chloride North America
27944 North Bradley Road
Libertyville, IL 60048
USA