C5CMXE-5364BK Data Sheet

Add to my manuals
2 Pages

advertisement

C5CMXE-5364BK Data Sheet | Manualzz

Rev. 05/30/13

CAT5E 350MHz Outdoor

Solid Direct Burial Shielded Bulk Cable

CAT 5E

AT

IS

FA

CTIO

N GUAR

AN

TE

ED

G GUA ON ON

Frequency

MHz

(Maximum)

31.25

62.50

100

250

350

10

16

20

25

1

4

8

Category 5E Outdoor Direct Burial SF/UTP 24 AWG

4 Pair 8 Solid Bare Copper Conductors, AL Foil

Shielding, LDPE Jacket 1000FT (ETL)

Applications

• 10/100/1000Base-T

• 100Base-VG

• 155 Mbps and 622-Mpbs ATM

• Other high-performance applications

▫ Outside Plant

▫ Direct Burial

▫ Aerial

Compliance

• ISO/IEC 11801

• TIA/EIA-568-C.2 Category 5e

• ANSI/ICEA S-90-661 Category 5e

• NEMA WC63.1 Category 5e

• ETL Verifi ed

• RoHS Compliance for the Requirement of European

Union Issued Directive 2002/95/EC

Physical Characteristics

• Conductor Size: 24AWG

• Conductor Material: Solid Bare Copper

• Insulation Material: High Density Polyethylene

(HDPE)

• Number of Conductors: 8 Conductors

• Number of Pairs: 4 Pairs

• Outer Shield Material: Aluminum Foil

• Drain Wire: Tinned Copper 0.45mm

• Outer Jacket Material: LDPE (Complies RoHS)

• Outer Jacket Diameter: 6.2mm ± 0.4mm

• Outer Jacket Rip Cord: Yes

Technical Diagram Available Jacket Colors

Black Item# C5CMXE-5364BK

Cable Features

• Tested to 350MHz.

• Meets or exceeds CAT5E TIA568C.2 standards.

• Cable is marked in descending order so you always know how

much cable is left.

• Extra headroom provides room for growth.

• Low attenuation and power-sum crosstalk.

Construction Facts

• This DB Outdoor Cable has high density polyethylene insulation.

• AL foil Shielding is used to help eliminate any interference in noisy

environments.

• Longitudinal rip cord for easy jacket opening.

Cable Put-Ups:

• Cable is supplied in 1000ft increments on a wooden spool.

17.1

24.8

32.0

52.44

63.13

9.6

12.3

13.6

15.2

CAT5E 350MHz Direct Burial Solid Bulk Cable Electrical Specifi cations

ATT dB/100 m

(328 ft.)

(Maximum)

ACR dB/100 m

(328 ft.)

(Maximum)

PS-ACR dB/100 m

(328 ft.)

(Minimum)

NEXT dB/100 m

(328 ft.)

(Minimum)

PS-NEXT dB/100 m

(328 ft.)

(Minimum)

ELFEXT dB/100 m

(328 ft.)

(Minimum)

PS-ELFEXT dB/100 m

(328 ft.)

(Minimum)

3.3

6.4

8.7

N/A

N/A

N/A

N/A

N/A

N/A

65.3

56.3

51.8

62.3

53.3

48.8

64.0

52.0

45.9

61.0

49.0

42.9

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

42.9

38.4

35.3

29.0

27.1

50.3

47.2

45.8

44.3

39.9

35.4

32.3

26.0

24.1

47.3

44.4

42.8

41.3

34.1

28.1

24.0

16.0

13.1

44.0

39.9

38.0

35.8

31.1

25.1

21.0

13.0

10.1

41.0

36.9

35.0

33.0

Return Loss dB

(Minimum)

20.0

23.0

24.5

23.6

21.5

20.1

15.6

14.3

25.0

25.0

25.0

24.3

PrimusCable.com - (951) 824-1571

RoHS

Page 1

Pair Color Code Chart

Pair 1 ----- White/Blue Stripe & Blue

Pair 2 ----- White/Orange Stripe & Orange

Pair 3 ----- White/Green Stripe & Green

Pair 4 ----- White/Brown Stripe & Brown

Mechanical Characteristics

• Storage Temperature Range: N/A

• Installation Temperature Range: N/A

• Operating Temperature Range: N/A

• Bulk Cable Weight: N/A / 1000FT

• Max. Recommended Pulling Tension: N/A

• Min. Bend Radius/Minor Axis: N/A

• Min. Bend/Installation: N/A

• Test Object: Jacket

• Test Material: PVC

• Before Tensile Strength: ≥10.0

▫ Aging Elongation: ≥350

▫ Aging Condition: 100°C x 24hrs x 10Days

• After Tensile Strength: N/A

▫ Aging Elongation: ≥300

▫ Cold Bend: No Visible Cracks (-40°C ± 2°C x 4h)

CAT5E 350MHz Outdoor

Solid Direct Burial Shielded Bulk Cable

Electrical Characteristics

• Nom. Mutual Capacitance: N/A

• Nominal Velocity of Propagation: N/A

• Maximum Delay: 537.60 @ 100MHz (ns/100m)

• Maximum Delay Skew: ≤ 45 (ns/100m)

• Maximum Conductor DC Resistance: 9.5 (@ 20°C OHm/100m)

• Maximum Operating Voltage - UL: N/A

• Maximum DCR Unbalanced: 5% (@ 20°C)

• Attenuation (Maximum)

▫ 32.0dB/100m (328.1ft.) @ 100MHz

▫ 63.13dB/100m (328.1ft.) @ 350MHz

• 1.0 - 100MHz Impedance: 100Ω ± 15%

• NEXT (Minimum)

▫ 35.3dB/100m (328.1ft.) @ 100MHz

▫ 27.1dB/100m (328.1ft.) @ 350MHz

• PS-NEXT (Minimum)

▫ 32.3dB/100m (328.1ft.) @ 100MHz

▫ 24.1dB/100m (328.1ft.) @ 350MHz

• Return Loss (Minimum)

▫ 20.1dB/100m (328.1ft.) @ 100MHz

▫ 14.3dB/100m (328.1ft.) @ 350MHz

Jacket Printing

N/A

Sequential foot markers on jacket.

Rev. 05/30/13

© 2013 CRN Solutions Inc. dba. Primus Cable

All Rights Reserved.

Although Primus Cable makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability.

Primus Cable provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or implied. In no event will Primus Cable be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Primus Cable has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.

All sales of Primus Cable products are subject to Primus Cable’s standard terms and conditions of sale.

Primus Cable believes this product to be in compliance with EU RoHS (Directive 2002/EC, 27 Jan 2003). Material manufactured prior to the compliance date may be in stock at Primus Cable facilities and in our Distributor’s inventory. The information provided in this Product

Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Primus

Cable’s knowledge, information, and belief at the date any other operation of the product itself or the one that it becomes a part of. This Product

Disclosure is not to be considered a warranty or quality specification and regulations based on their individual usage of the product.

Primus Cable declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC

Page 2

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement