736-B - Bradford White
Brute™ Elite Volume Water Heaters
Indoor 150,000 - 850,000 BTU/Hr.
Up to 97% Thermal Efficiency
The unit will be designed and constructed in accordance with the ASME Boiler and Pressure Vessel Code Section IV requirements for 160 psi working pressure.
The units will bear the ASME "H" stamp and be registered by the National Board.
5-Year Limited Heat Exchanger Warranty / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties.
See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012.
736-B 0814-A
Brute™ Elite Volume Water Heater Specifications - Sizes 150-500
Dimensions shown in inches cm
Dimensions
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
A
B
C
D
E
F
G
J
K
M
N
W
L
H
in.
131/4
201/2
201/4
25
301/4
in.
51/4
51/4
71/4
51/4
51/4
in.
19
19
193/4
193/4
193/4
in.
31/4
31/4
41/4
41/4
41/4
in.
103/4
173/4
111/4
143/4
151/4
in.
71/2
71/2
131/2
181/2
20
in.
141/4
141/4
14
191/4
201/2
in.
191/2
191/2
15
161/2
19
in.
71/2
113/4
17
213/4
26
in.
151/4
151/4
183/4
183/4
183/4
in.
13
13
13
13
13
in.
25
25
25
25
25
in.
191/2
263/4
263/4
311/2
373/4
in.
381/4
381/4
381/4
381/4
381/4
A
B
C
D
E
F
G
J
K
M
N
W
L
H
cm
34
52
52
64
77
cm
14
14
19
13
13
cm
48
48
50
50
50
cm
8
8
16
11
11
cm
28
45
29
37
38
cm
19
19
34
47
51
cm
36
36
36
49
52
cm
49
49
38
42
48
cm
19
30
43
55
66
cm
39
39
48
48
48
cm
33
33
33
33
33
cm
64
64
64
64
64
cm
49
68
68
80
96
cm
97
97
97
97
97
*Brute Elite is shipped with adapters for the air and vent that accept standard pipe of the proper size and type.
Air
Inlet
Conn.
in.*
3
3
41/2
41/2
41/2
Vent
Conn.
Air
Inlet
Conn.
cm*
7.6
7.6
11
11
11
Vent
Conn.
in.*
3
3
41/2
41/2
41/2
cm*
7.6
7.6
11
11
11
Connections
NPT Size
Water
Gas
in.
in.
1/2
11/4
1/2
11/4
3/4
2
3/4
2
1
2
Connections
NPT Size
Water
Gas
cm
cm
3.2
3.2
3.2
3.2
5.1
5.1
5.1
5.1
5.1
5.1
Brute™ Elite Volume Water Heater Specifications - Sizes 600-850
Dimensions shown in inches cm
Dimensions
Model
Number
BNTV-600
BNTV-750
BNTV-850
Model
Number
BNTV-600
BNTV-750
BNTV-850
A
B
C
D
E
F
G
J
K
M
N
W
L
H
in.
29 3/4
351/2
39 3/4
in.
5
6
6
in.
191/2
191/2
191/2
in.
41/4
51/4
51/4
in.
15
19
19
in.
20
401/2
44 3/4
in.
3
31/4
31/2
in.
19
19
19
in.
26
30 3/4
35
in.
18 3/4
18 3/4
18 3/4
in.
81/4
81/4
81/4
in.
25
25
25
in.
37 3/4
51
55 1/4
in.
381/4
381/4
381/4
A
B
C
D
E
F
G
J
K
M
N
W
L
H
cm
76
90
101
cm
13
15
15
cm
50
50
50
cm
11
13
13
cm
38
48
48
cm
51
103
114
cm
8
8
9
cm
48
48
48
cm
66
78
79
cm
48
48
48
cm
21
21
21
cm
64
64
64
cm
96
130
130
cm
97
97
97
*Brute Elite is shipped with adapters for the air and vent that accept standard pipe of the proper size and type.
Air
Inlet
Conn.
in.*
41/2
41/2
41/2
Vent
Conn.
Air
Inlet
Conn.
cm*
11
11
11
Vent
Conn.
in.*
41/2
61/2
61/2
cm*
11
17
17
Connections
NPT Size
Water
Gas
in.
in.
2
1
2
11/2
2
11/2
Connections
NPT Size
Water
Gas
cm
cm
5.1
2.5
5.1
3.8
5.1
3.8
Brute™ Elite Volume Water Heater Specifications
Sizing Data
Clearances
Input
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
BNTV-600
BNTV-750
BNTV-850
BTU/Hr.
150,000
199,000
285,000
399,000
500,000
600,000
750,000
850,000
Output
BTU/Hr.
142,500
193,030
270,750
383,040
480,000
582,000
705,000
816,000
kW
44.0
58.3
83.5
116.9
146.5
175.8
219.8
249.1
Thermal
Efficiency
kW
41.8
56.6
79.4
112.3
140.7
170.6
206.6
239.2
%
95.0
97.0
95.0
96.0
96.0
97.0
94.0
96.0
Shipping
Weight
lbs.
220
245
350
410
480
394
469
502
Appliance
Surface
kg.
100
111
159
186
218
179
213
228
Left Side
Right Side
Top
Back
Closet, Front (285-500)
Alcove, Front (285-500)
Front (600-850)
Vent
Suggested Service
Access Clearance
in.
cm.
1
2.5
12
31
24
61
6
15
6
15
24
61
24
61
—
—
Certified by CSA for zero clearance to
combustible materials on all sides.
Vent System
Max. Equivalent* Vent Length PVC/CPVC (each intake and each exhaust)
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
BNTV-600
BNTV-750
BNTV-850
Air Intake Air Intake
Dia.
Dia.
in.
cm
3
3
3
4
4
4
4
6**
4
6
4
6
7.6
7.6
7.6
10.1
10.1
10.1
10.1
15.2**
10.1
15.2
10.1
15.2
Ex. Vent
Dia.
in.
Ex. Vent
Dia.
cm
3
3
3
4
4
4
4
6**
4
6
4
6
7.6
7.6
7.6
10.1
10.1
10.1
10.1
15.2**
10.1
15.2
10.1
15.2
Max.
Allowable
Length
30 m.
100 ft.
30 m.
100 ft.
6.1 m.
20 ft.
30 m.
100 ft.
30 m.
100 ft.
100 ft.
30 m.
40 ft.
12 m.
100 ft.** 30 m.**
40 ft.
12 m.
100 ft.
30 m.
40 ft.
12 m.
100 ft.
30 m.
Installations in the U.S. require exhaust vent pipe that is a combination of
PVC & CPVC complying with ANSI/ASTM D1785 F441, polypropylene pipe
that conforms with ULC S636, or stainless steel complying with UL1738.
Installations in Canada require exhaust vent pipe that is certified to ULCS636.
Installer must comply fully with manufacturer's installation instructions,
including use of minimum exhaust length CPVC, to maintain ANSI Z21.13
safety certification.
Closet and alcove installations do not allow the use of PVC under any
circumstances
*To calculate max equivalent length, measure the linear feet of the pipe, and
add 5 feet (1.5m) for each elbow used.
Intake (air) pipe may be ABS, PVC, CPVC or galvanized material.
** Allowed only if the vent pipe is no more that 20 equivalent feet
longer than the air pipe.
Water Flow Requirements
Electrical Data
Models
Boiler
(Includes Pump)
Volts Phase
Amps
150-500 (No Pump)
150-199 (With Pump)
285-500 (With Pump)
120
120
120
Single
Single
Single
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
BNTV-600
BNTV-750
BNTV-850
2*
7*
8*
* Minimum 15A circuit required.
600-850 pump not included.
Flow
GPM
19.0
25.0
36.0
50.0
63.0
60.0
68.0
68.0
H/L
Ft.
57.0
28.0
33.0
35.0
28.0
24.0
35.0
26.0
Normal Water*
Temp.
Flow
Rise °F
LPM
15.0
72.0
15.0
95.0
15.0
98.0
15.0
189.0
15.0
239.0
19.0
227.0
21.0
257.0
24.0
257.0
H/L
m
17.4
8.5
10.1
10.7
8.5
7.3
10.7
7.9
Temp.
Rise °C
8.0
8.0
8.0
8.0
8.0
11.0
12.0
13.0
* Maximum water hardness of 10 grains per gallon allowed.
Recovery Data
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
BNTV-600
BNTV-750
BNTV-850
40°F
GPH
432
585
821
1161
1455
1764
2136
2473
50°F
GPH
346
486
656
929
1164
1411
1709
1978
Required Water Temperature Rise
60°F 70°F 80°F 90°F 100°F
GPH GPH GPH GPH GPH
288 247 216 192 173
390 334 293 260 234
547 469 410 365 328
774 663 580 516 464
970 832 727 647 582
1176 1008 882 784 706
1424 1221 1068 950 855
1649 1413 1236 1099 989
120°F
GPH
144
195
274
387
485
588
712
824
140°F
GPH
123
167
234
332
416
504
610
707
Model
Number
BNTV-150
BNTV-199
BNTV-285
BNTV-399
BNTV-500
BNTV-600
BNTV-750
BNTV-850
22°C
L/h
1635
2214
3108
4395
5508
6677
8086
9361
28°C
L/h
1310
1840
2483
3517
4406
5341
6469
7488
Required Water Temperature Rise
33°C 39°C 44°C 50°C 56°C
L/h
L/h
L/h
L/h
L/h
1090 935 818 727 655
1476 1264 1109 984 886
2071 1775 1552 1382 1242
2930 2510 2196 1953 1756
3672 3149 2752 2449 2203
4452 3816 3339 2968 2673
5390 4622 4043 3596 3237
6242 5349 4679 4160 3744
67°C
L/h
545
738
1037
1465
1836
2226
2695
3119
76°C
L/h
466
632
886
1257
1575
1908
2309
2676
Brute™ Elite Volume Water Heater Specifications
1 2 3
B N T
4
V
SERIES
USAGE
5 6 7
8
9
10
11
3
SIZE
FUEL
N
P
OPTION
CODE
PUMP
OPTION
REVISION
150
199
285
399
500
600
750
850
X
J
N
X
3
Model Character Designation
(1-3) Model Series Designation
BNT = Brute Elite
(4) Usage
V= Volume Water
(5-7) Size
150 = 150,000
199 = 199,000
285 = 285,000
399 = 399,000
500 = 500,000
600 = 600,000
750 = 750,000
850 = 850,000
BTU/Hr.
BTU/Hr.
BTU/Hr.
BTU/Hr.
BTU/Hr.
BTU/Hr.
BTU/Hr.
BTU/Hr.
Input
Input
Input
Input
Input
Input
Input
Input
(8) Fuel
N = Natural Gas
P = Propane
(9) Options
X = None
J =CSD-1,
FM, GAP,
IL (500-850 only))
(10) Pump Options
N = Normal Pump (150-500 only)
X = No Pump
(11) Revision
3 = Third Revision
Standard Features
■ Large LCD display with touchpad userinterface
■ Menus for login, display setup, quick
start, advanced setup, test and
diagnostics
■ Password-protected parameters for
installer use
■ Customizable homescreen and LCD
contrast
■ Quick start feature for simple, single
heater installations
■ Test feature allows forced min or max
firing
■ Complete diagnostics for analog and
digital inputs
■ Displays holds, alerts and errors in clear
text form
■ Dry alarm contacts for ignition failure
■ High condensing efficiency
■ Modulation down to 20% of full fire (5:1
turndown)
■ Sealed combustion chamber
■ Pre-mix stainless steel burner
■ Low NOx system exceeds the most
stringent regulations for air quality - less
than 10ppm NOx
■ Horizontal or vertical direct vent
■ Horizontal vent and air terminals
■ Vent and air pipe lengths of up to 100
equivalent feet (each)
■ Built-in condensate trap
■ Vent temperature cutoff feature
■ Direct spark ignition system
■ Sensor for domestic water tank
■ 160 psi maximum working pressure
■ Stainless steel heat exchanger with
welded construction (no gaskets)
■ ASME "H" stamp
■ 125 psi (861 kPa) ASME rated pressure
relief valve
■ Water flow switch (399-850 only)
■
■
■
■
■ Additional auto reset high limit
■ High and low gas pressure switches
(500-850)
■ Alarm bell w/silence switch for ignition
failure
■ 60 PSI pressure relief valve
■ 75 PSI pressure relief valve
■ 150 PSI pressure relief valve
■
■
■
■
■
■
■
■
■
Temperature & pressure gauge
Cascades with other NeoTherms
Drain valve
Integrated PID temperature and ignition
controls
Electronic PID modulating control
Alarm output
Accepts external (4-20mA or 0-10V)
modulation signal
On/off toggle switch
Manual reset high limit
Burner site glass
Zero clearance to combustible surfaces
Built-in cascade function for up to eight
Brute™ Elites
5 year limited warranty
Factory Mounted Options
■ CSD-1, FM, GAP, IL code equipment
(500-850) - includes LWCO (low water
cutoff), high and low pressure switches
■ LWCO (500-850)
Accessories for Field Mounting
■
■
■
■
■
■
■
Water flow switch (150-285)
LWCO
High and low gas pressure switches
Propane conversion kit
Condensate neutralizer kit
BACnet gateway
LON gateway
■
■
■
■
2"
3"
3"
4"
PVC
PVC
PVC
PVC
Concentric Vent Terminal (150-199)
Concentric Vent Terminal (150-285)
Flush Mount Terminal (150-285) (side wall only)
Flush Mount Terminal (285-850) (side wall only)
Brute™ Elite Volume Water Heater Specifications
Sample Specification
The heater shall be a Bradford White Model BNTV__________, rated at the input and output shown on the schedule. The heater shall modulate 20-100% of
full fire. The unit(s) shall be design-certified to comply with the current edition of the Harmonized ANSI Z21.13 / CSA 4.3 Standard for Gas-Fired Low Pressure
Steam and Gas Water Heaters. The unit(s) shall be designed and constructed in accordance with the ASME Boiler & Pressure Vessel Code, Section IV
requirements for 160 psi (1103 kPa) maximum working pressure, and shall bear the ASME "H" Stamp and be listed by the National Board. The unit(s) shall be
constructed to comply with the efficiency requirements of the latest edition of ASHRAE Standard 90.1. The heater shall be equipped with an ASME certified
relief valve set at 125 psi (861 kPa).
The water tube heat exchanger shall be stainless steel, rated at 160 psi (1103 kPa) working pressure. The heat exchanger shall be a low water volume design,
welded construction, with no gaskets, o-rings or bolts in the header. Heat exchanger shall be accessible for visual inspection and cleaning of all internal
surfaces. The heater shall be fully condensing design with built-in condensate drain and tap. The heat exchanger shall have a limited five-year warranty.
Each heater shall be fully test fired, (with water, gas, and venting connected), and all safety components tested, at the factory.
150-500 models shall be shipped with a pump and a conduit. The wiring and terminals shall be wired to the pump. The heater shall have a flanged inlet water
connection that allows the pump to be connected directly to the top of the heater in the field. The pump shall be capable of serving the heaters's heat exchanger
and 30 feet (9m) of piping that is the same size as the heater's water connections, with a normal amount of pipe fittings.
The heater shall use a premix burner with a stainless steel woven metal fiber wrap, and a negative pressure gas valve to burn cleanly, with NOx emissions not
exceeding 10ppm. The heater shall meet the emissions requirements of SCAQMD 2012.
The heater shall be designed for the vertical or horizontal Category IV venting, up to 100 equivalent feet (30m) with a PVC, CPVC, polypropylene that complies
with ULC S636, or stainless steel vent material. Air may be taken from the room, or ducted directly to the heater, using up to 100 equivalent feet (30m) ABS,
PVC, CPVC. The heater shall be shipped with PVC sidewall vent and air terminals, for use with horizontal systems. The first section of CPVC vent pipe shall be
shipped with each heater.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 ● Fax 215-641-1670 / Technical Support 800-334-3393 ● Fax 269-795-1089 ● Warranty 800-531-2111 ● Fax 269-795-1089
International: Telephone 215-641-9400 ● Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ● Fax 905-238-0105 / www.bradfordwhite.com
©2014, Bradford White Corporation. All rights reserved.
736-B-0814-A
Printed in U.S.A.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising